Professional Documents
Culture Documents
CONTENTS
Introduction Block diagram of ECG monitoring system Hardware Functionality Circuit diagrams System developing tools esults Conclusion eferences
INTRODUCTION
The medical monitoring system which are
HARDWARE FUNCTIONALITY
ARM7TDMI ECG MODULE GPRS MODULE LCD DISPLAY MAX232-MAX2323 IC
ARM7TDMI
ARM stands for advanced RISC machines In this project using Philips LPC 2138 microcontroller with an ARM7TDMI processor core. ARM7TDMI-S processor, running at up to 72 MHz. ARM7TDMI is a 32 bit processor Up to 64 kB of SRAM on the ARM local bus for high performance CPU access.
ARM7TDMI
10bit A/D converter with input multiplexing among 8 pins and 10 bit D/A converter. General purpose timers. PWM/Timer block with support for three-phase motor control. External count inputs. Real-Time Clock (RTC) with separate power pin 2 kB Static RAM powered from the RTC power pin, allowing data to be stored when the rest of the chip is powered off. Watchdog Timer.
ARM7TDMI
In this project the main modules of ARM7TDMI that are going to use are UART ADC GPIO UART stands for universal asynchronous receiver
transmission.
It
is
used
for
transmission
and
reception of data. ADC stands for analog to digital conversion. We have 10 bit 8 channel ADC.
Direction of each pin (0input 1- output) 1-Port set; 0- not affect 1-Portclear; 0- not affect Pin status
UART
In ARM7TDMI ,UART is used for transmission and reception of data. At a time 1 byte of data is received or transmitted. 16 byte Receive and Transmit FIFOs. UART1 with the addition of a modem interface. UART3 includes an IrDA mode to support infrared communication.
UART REGISTER
RXD0 TXD0
7 6
Input Output
5 4 3 2 1 0
U0RBR
Receiver Buffer Transmit Holding Register Divisor latch LSB Divisor latch MSB Line control Register
U0THR
U0DLL
U0DLM
U0LCR
Stick parit y
ADC
We have 1 ADC channels in ARM7TDMI It is a 10-bit 8 channel ADC It takes 2.44 s for conversion of ANALOG values to DIGITAL value. Measurement range 0 to 3 . ADC has a power down mode i.e. even when the processor goes to sleep mode A/D conversion will still continue
ADC REGISTER
ADCR ADDR Control Register Data Register
ADCR
31-28 27 26-24 23-22 21 20 19-17 16 15-8 7-0
EDGE
START
PDN
CLKS
BURST
CLKDI
SEL
ADDR
31 DONE 30 OVERUN 29-27 26-24 CHN 23-16 15-6 V/Vref 5-0 -
LCD DISPLAY
A 4 bit LCD display used in this project. The LCD has a 16X2 display. It consists of 16 pins in which 4 pins are used for data/command 3 control pins
GPRS MODULE
GPRS module is used for sending the ECG signal value to the control station. At first we pass AT in order to initialize GPRS along with enter key We have a set of instructions known as the AT command set in order to initialize the GPRS module. We then get an OK from the GPRS module
MAX232-MAX2323 IC
This is an RS-232C standard IC which is used for serial communication. It is used for interfacing the microcontroller with GPRS module. This IC is used in applications where 12v is not available.
Max 2323
LCD
Voltage Regulator
Developing tools
Software side
Keil 4uv LPC 23xx Flash utility
Hardware side
Express PCB
PC side
Visual Basic
LCD output
H/W Module
Reception at PC side
ECG output
Conclusion
Introduces the design of a very efficient low-cost ECG monitoring system interface to a GPRS module. highly flexible and user-specific.
References
[1] Wang Xiaohong Liu Li Inf. & Eng. Dept., Shandong Jiaotong Univ., Jinan, China; The design of Remote medical monitoring system based sensors and GPRS Information technology and application,2009. IFFTA09
international forum. Volume: 3. Issue Date: 15-17 May 2009 On page(s): 516 - 519 [2] De Capua .C.Meduri Dayu.A,Morello R: Wang, Kaiping Yu, Hong Guo; Instrumentation and measurement ,IEEE transaction on Volume : 59
,Issue 10, publication year 2010 . [3]M. Malik and A.J Camm., Heart Rate Variability., Futura Publishing Co. Inc., Sept.1995
References
[4] Bai V.T.; Real time portable telemedicine system for cardiac patient., Biomedical information Engineering,2009.,International conference on Future. Publication Year: 2009 , Page(s): 57 - 60 [5] Boskovic, A.; Despotovic, M; An Efficient Approach to ECG Signal Transmission via GPRS. The international conference on Computer as a Tool, EUROCON 2005. Volume:1. Publication Year:2005, Page(s): 76 - 79 . [6] Cai Ken; Liang Xiaoying; Development of remote monitoring cardiac patient system based on GPRS.2010 International Conference on Biomedical Engineering and computer science. : Publication Year: 2010 , Page(s): 1 - 4 [7] Xin Ge; Dakun Lai; Zuxiang Fang;A Real time continous ECG Transmittting metod through GPRS with low power consumption,, The 2nd International Conference on. Bioinformatics and Biomedical Engineering 2008 ICBBE2008 Publication Year: 2008 , Page(s): 556 559.
References References
[8] Jianwei Dong; Shi Zhang; Xiaonan Jia; A Portable Intelligent ECG monitor based on Wireless internet and Embedded system Technology., Biomedical Engineering and informatics,2008.,International conference.Volume: 2 Publication Year: 2008 , Page(s): 553 - 556 [9] Andrew N. Sloss, Dominic Symes, Chris Wright System ARM System
Developers edition,2005
GuideDesigning
and
Optimizing
Software,3rd
[10] Steve Furber. ARM System-on-Chip Architecture. Addison-Wesley,2nd edition, 2000. [11] David Seal , Addison-Wesley ARM Architecture Reference Manual 2nd edition.