You are on page 1of 17

Single Cell Functional Test Report - SCFT

Site ID

MAKAA1 KANPUR BKP0405 MSELN03

Zone / Cluster

Bsc

Msc

Drive Test Performed By

KAILASH JOSHI
15-MARCH-12 ABHIJEET SINGH

Date

Analysis and Report Prepared By

Date

15-MAR-12

SCFT CHECKLIST Site Name: MAKAA1 Circle & City Name: KANPUR Lat/Long: 26.89861/ 79.9789 Site Type (Sharing/Anchor) :Sharing ALU Vendor Name: SCFT TEST RESULT Description

Site ID: UW_UPEast_6023 BTS Vendor & Model: Ericsson-6101 Cluster ID: Date:16.03.2012 BTS TYPE (ID/OD): OD PASS/FAIL PASS/FAIL Sector-1 Sector-2 2 HBX 6516 DS VMT 35 50 1 0 Yes 636 5 PASS PASS 1 -56 dBm(82m) 2 HBX 6516 DS VMT 35 140 1 0 Yes 638 5 PASS PASS 1 -57 dBm(63m) Pass Pass

PASS/FAIL Sector-3 2 HBX 6516 DS VMT 35 350 1 0 Yes 708 5 PASS PASS 1 -58 dBm(110m)

Remarks

Sl.No. 1
2 3 4 5 6 7 8 9 10 11 12 13 14 a b c d e f

BTS Config (TRX) Antenna Type Antenna Height (Mt) Antenna Azimuth Installed Electrical Tilt Mechanical Tilt Check for Feeder Swap BCCH (Scanned) Call Initiated Voice (All Scenarios MOC/MTC etc) PS Call test Rx Qual RX Level (Near Site) dBm Draw handovers tested: Sector 1 to 2 Sector 2 to 3 Sector 3 to 1 Sector 1 to 3 Sector 3 to 2 Sector 2 to 1

Average

Pass

Pass Pass
Pass Pass Pass

Pass Pass Pass Pass

RF SINGLE SITE CHECK SHEET


The following is to be checked during Single Site Check: Yes Antenna orientation: YES Feeder installation (swapped feeders) :YES BCCH Plan (as per design ) :YES Voice call set-up :YES Handover (driving around the site in both directions) : YES

Analysis, Observations & Recommendations:

Serving Cell ID MAKAA1A MAKAA1B MAKAA1C

Neighbor Cell Neighbor Cell ID BCCH MAKAA1B 638 MAKAA1C 708 MAKAA1A 636 AROUL1A AROUL1B BILHA1C 711 638 711

BCC 4 4 4 1 7 0

NCC 3 3 3 1 4 5

Incomin Outgoin g HO 1- g HO 1Tier Tier

Remarks Attempt Attempt Attempt Attempt Attempt Attempt

BCCH PLOT 6023

RX LEVEL 6023

RX Level With Prediction Plot

Rx Quality 6023

C/I Plot 6023

Short Call
Event #[No. of samples] % Measurement

Blocked Call Call Attempt


Call Setup Dropped Call Call Success TCH Call Drop Rate Call setup Success Rate

0 52
52 0 100 0 100

Long Call
Information Element Range % of Meas. 78.1 21.9 No. of Samples Total Samples

Rx Qual sub Rx Qual sub Handover Handover Failure Handover Success Handover Success Rate

<=5 >5

3062 861

3923 3923 37 0

100 100

Event Statistic
RX Level (Dbm)
0 -65 -65 -75 -75 -85 -85 -95 -95 -105

Sample
1211 911 662 1187 246

Percentage (%)
28.7 21.6 15.7 28.1 5.8

RX Qual
0-5
5-6 6-7

Sample
3062
290 571

Percentage (%)
78.1
7.4 14.6

INTRODUCTION
The purpose of this document is to perform according to specifications and RF design. It shall fulfill the design objectives. Both coverage and functionality tests will be performed to evaluate every cell in the network. At the end of the exercise the RF engineer should be able to: Verify correct antenna orientation and fix swapped sectors, if any. Ensure that basic cell functionalities are executed properly and systematically. Document and compile log files and test sheets for each site tested. These can be useful references, especially while during cluster tuning. Data fill verification.

TEAM REQUIREMENT
Drive Test Engineer Rigger

TOOLS USED
Tool setup and Test process
Upon arrival at the site, Engineer would validate site design information. This information must be checked against the antenna design plan. A laptop with drive test software is needed to make test calls and to check cell parameters. Perform test the following call scenarios in each sector; please refer to SCFT Checklist for details: Verification of Correct Antenna Orientation and correct BCCH on each Sector. Verification of Handover and Signal Quality. MM (mobile-to-mobile) calls. Engineer Should Start in First Sector, perform all Voice Test and proceed to Sector 2 ( record Handover from Sector 1-2), perform all tests in Sector 2 and finish all 3 sector tests to stop at starting point. The same process should follow in reverse directions from start to stop point.

Tools used for the drive test are: Drive Test Car, equipped with drive test facilities, GPS with cord to laptop (COM port) & I/O card for extra dual COM port. Highly Stable DC power distribution system, DC/AC Inverter if required for laptop. Uninor SIM cards. And below mentioned tools; (please specify in below table)
1. 1. 1. 1. 1. GSM Please specify the test mobile model (MS 1) Please specify the test mobile model (MS 2) Drive Test Software and its version Type / Model Drive Test Analysis Software & Version # Specification / Details 6230I 6230I NEMO 4.2

NEMO 4.2

Tools used to generate this report are:


Drive Test Tool / Software Name : Analysis Tool Name & Version : MapInfo Version : NEMO 4.2 ACTIX ANALAYZER

A brief procedure descriptions

The procedure for the drive tests is described below: SCFT drive tests shall be performed by 3 call scenarios as given below; MS1 = Idle MS2 = Long call (MS to Test Number, 10 sec call interval if call drops) MS3 = Short call (MS to MSC Test Number, 45sec call duration, 10 sec call interval)

Documentation
The following documentation defines the completion of SCFT test:

Ref.

Test Description

Comments

Cell Design Data

yes

Drive Test Report (SCFT Checklist Completed

yes

Drive Test Log Files

yes

.. RF Engineer / RF lead RF SME <Vendor Name> RF Engineer /RF Lead Uninor MS / Uninor Team

.. Alcatel-Lucent India Ltd.