You are on page 1of 8

s

What transfer options are available in the various operator panels?

Entry-ID: 19109408

Key: P= K= D= U= Process coupling Optional process coupling Download (update operating system, project, backup/restore, ) Booting (filling in the case of a missing or damaged operating system)

S5-TTY
(PG-S5)

S5-TTY
(TD/OP-S5)

S7 PG702

RS232
external

TD-PPI
(incl. voltage)

RS232
Zero-modem

RS232/PPI
Multi-Master Cable

USB/PPI
Multi-Master Cable

MPI (PG-S7)
by 187,5 kBaud

6ES5 7342xxxx PP7 PP17 I PP17-II KP8 KP8F TD100C TD200 TD200C TD17 C7-621 (OP3) C7-623 (OP5)
4) 4) 4) 4)

6XV1 440- 6ES7 705-0AA00- 6XV1 440- 6ES7 901-3EB10- 6ES7 901-1BF002Axxx P D/U 7BA0 P D/U D/U D/U 2Kxxx P P P 0XA0 D/U D/U D/U 0XA0 -

6ES7 901-3CB300XA0 -

6ES7 901-3DB300XA0

6ES7 901-0BF000AA0 P P P D D D D D D -

D 4)

D/U D/U D/U -

C7-624 (OP15) C7-626 (OP25) C7-633 (OP7) C7-634 (OP17)

4) 4)

C7-635 (TP/OP170B) C7-636 (OP 270) KP300 Basic PN


4)

Changedate: 01.08.2011

This entry is from the Service&Support portal of Siemens AG, Sector Industry, Industry Automation and Drive Technologies. The general terms of use (http://www.siemens.com/terms_of_use) apply.

Page: 1/8

What transfer options are available in the various operator panels?

Entry-ID: 19109408

S5-TTY
(PG-S5)

S5-TTY
(TD/OP-S5)

S7 PG702

RS232
external

TD-PPI
(incl. voltage)

RS232
Zero-modem

RS232/PPI
Multi-Master Cable

USB/PPI
Multi-Master Cable

MPI (PG-S7)
by 187,5 kBaud

6ES5 7342xxxx KTP400 Basic mono PN KTP400 Basic mono PN Portrait KTP600 Basic mono PN KTP600 Basic mono -

6XV1 440- 6ES7 705-0AA00- 6XV1 440- 6ES7 901-3EB10- 6ES7 901-1BF002Axxx 7BA0 P 2Kxxx 0XA0 D/U D/U 0XA0 -

6ES7 901-3CB300XA0 -

6ES7 901-3DB300XA0

6ES7 901-0BF000AA0 P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D

PN Portrait KTP600 Basic color DP KTP600 Basic color DP Portrait KTP600 Basic color PN KTP600 Basic color PN Portrait KTP1000 color DP KTP1000 color PN TP1500 color PN KP400 Comfort KTP400 Comfort KP700 Comfort TP700 Comfort TP900 Comfort KP900 Comfort TP1200 Comfort KP1200 Comfort TP070 TP 170micro TP 177micro TP 170A 6" TP 170B 6" mono -

D/U D/U D/U D/U D/U D/U -

D/U D/U D/U D/U -

Changedate: 01.08.2011

This entry is from the Service&Support portal of Siemens AG, Sector Industry, Industry Automation and Drive Technologies. The general terms of use (http://www.siemens.com/terms_of_use) apply.

Page: 2/8

What transfer options are available in the various operator panels?

Entry-ID: 19109408

S5-TTY
(PG-S5)

S5-TTY
(TD/OP-S5)

S7 PG702

RS232
external

TD-PPI
(incl. voltage)

RS232
Zero-modem

RS232/PPI
Multi-Master Cable

USB/PPI
Multi-Master Cable

MPI (PG-S7)
by 187,5 kBaud

6ES5 7342xxxx TP 170B 6" color TP 177A 6" TP 177A 6" Portrait TP 177B 4 color PN/DP TP 177B 6" mono DP TP 177B 6" color PN/DP TP 270 6" TP 270 10" TP 277 6" OP 73micro OP3 OP 73 OP7 PP OP7 DP OP7 DP12 OP17 PP OP17 DP OP17 DP12 OP 77A OP 77B OP 170B 6" mono DP OP 177B 6" mono DP OP 177B 6" color PN/DP OP 270 6" OP 270 10" D D D D -

6XV1 440- 6ES7 705-0AA00- 6XV1 440- 6ES7 901-3EB10- 6ES7 901-1BF002Axxx P/D 7BA0 P P P P 3) P 3) P 3) P P P 3) P/D D P/D P/D D P/D P P 3) P 3) P P 2Kxxx P P 1) P D/U D/U D/U D/U D/U D/U 0XA0 D/U 0XA0

6ES7 901-3CB300XA0 D/U D/U D D/U D/U D/U D/U D/U D/U D/U D/U -

6ES7 901-3DB300XA0 D/U D/U D/U D/U D/U -

6ES7 901-0BF000AA0 P/D P/D P/D P/D P/D P/D P/D P/D P/D P P1)/D1) P/D P P P P P/D P/D P/D P/D P/D P/D P/D

P P P P -

Changedate: 01.08.2011

This entry is from the Service&Support portal of Siemens AG, Sector Industry, Industry Automation and Drive Technologies. The general terms of use (http://www.siemens.com/terms_of_use) apply.

Page: 3/8

s
S5-TTY
(PG-S5)

What transfer options are available in the various operator panels?

Entry-ID: 19109408

S5-TTY
(TD/OP-S5)

S7 PG702

RS232
external

TD-PPI
(incl. voltage)

RS232
Zero-modem

RS232/PPI
Multi-Master Cable

USB/PPI
Multi-Master Cable

MPI (PG-S7)
by 187,5 kBaud

6ES5 7342xxxx OP 277 6" MP 177 6" Touch MP 270 MP 270B 6" Touch MP 270B 10" Touch MP 270B 10" Key MP 277 8" Touch MP 277 8" Key MP 277 10" Touch MP 277 10" Key MP 370 12" Touch MP 370 12" Key MP 370 15" Touch MP 377 12" Touch MP 377 12" Key MP 377 15" Touch MP 377 19" Touch Mobile Panel 170 Mobile Panel 177 DP Mobile Panel 177 PN Mobile Panel 277 Mobile Panel 277 (F) IWLAN (betrifft Ethernet Schnittstelle)
1) With gender changer

6XV1 440- 6ES7 705-0AA00- 6XV1 440- 6ES7 901-3EB10- 6ES7 901-1BF002Axxx P P P P 7BA0 2Kxxx P 3) P 3) P P P P P 3) P P
3) 3)

6ES7 901-3CB300XA0 D/U D/U D/U D/U D/U D/U D D D D D/U D/U D/U -

6ES7 901-3DB300XA0

6ES7 901-0BF000AA0 P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D -

0XA0 D/U D/U D/U D/U D/U D/U D/U D/U -

0XA0

P 3) P P P P 3) P P 3) 3)

P 3)

2) By using PN-IRT (with cycle synchronicity) IRT- ability switches are required 3) Only in conjunction with the RS422/232 converter 4) Internal data link to the PLC

Changedate: 01.08.2011

This entry is from the Service&Support portal of Siemens AG, Sector Industry, Industry Automation and Drive Technologies. The general terms of use (http://www.siemens.com/terms_of_use) apply.

Page: 4/8

What transfer options are available in the various operator panels?

Entry-ID: 19109408

Key: P= K= D= U= Process coupling Optional process coupling Download (update operating system, project, backup/restore, ) Booting (filling in the case of a missing or damaged operating system)

DP PtP 6XV1 8300Axxx PP7 PP17 I PP17-II KP8 KP8F TD100C TD200 TD200C TD17 C7-621 (OP3) C7-623 (OP5)
4) 4) 4) 4)

DP Standard Standard Profibus P P P P D D D D D D -

DP
(Mobile Panel)

PN (cross cable)
Point to point

PN Ethernet Standard

2)

PN
(Mobile Panel cable)

Conv.
RS422-RS232

Conv.
RS232-TTY (20mA)

90 Winkel
(9 pol. 1:1)

6XV1 4404Axxx P P P/D/U P/D/U P/D/U

6XV1 8703RH20 P P K/D

6XV1 4404Bxxx -

6AV6 671-8XE000AX0 -

6ES5 734-1BD20

6AV6 671-8XD000AX0 P/D/U -

Ethernet CAT5

P P P P 4)

C7-624 (OP15) C7-626 (OP25) C7-633 (OP7) C7-634 (OP17)

4) 4)

C7-635 (TP/OP170B) C7-636 (OP 270) KP300 Basic PN KTP400 Basic mono PN KTP400 Basic mono PN Portrait
4)

P/D/U P/D/U P/D/U

Changedate: 01.08.2011

This entry is from the Service&Support portal of Siemens AG, Sector Industry, Industry Automation and Drive Technologies. The general terms of use (http://www.siemens.com/terms_of_use) apply.

Page: 5/8

s
DP PtP 6XV1 8300Axxx KTP600 Basic mono PN KTP600 Basic mono PN Portrait KTP600 Basic color DP KTP600 Basic color DP Portrait KTP600 Basic color PN KTP600 Basic color PN Portrait KTP1000 color DP KTP1000 color PN TP1500 color PN KP400 Comfort KTP400 Comfort KP700 Comfort TP700 Comfort TP900 Comfort KP900 Comfort TP1200 Comfort KP1200 Comfort TP070 TP 170micro TP 177micro TP 170A 6" TP 170B 6" mono TP 170B 6" color TP 177A 6" TP 177A 6" Portrait TP 177B 4 color PN/DP TP 177B 6" mono DP P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P P P P P/D P/D P P P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P P P P P/D P/D P P P/D P/D DP Standard Standard Profibus -

What transfer options are available in the various operator panels?

Entry-ID: 19109408

DP
(Mobile Panel)

PN (cross cable)
Point to point

PN Ethernet Standard

2)

PN
(Mobile Panel cable)

Conv.
RS422-RS232

Conv.
RS232-TTY (20mA)

90 Winkel
(9 pol. 1:1)

6XV1 4404Axxx P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U -

6XV1 8703RH20

6XV1 4404Bxxx -

6AV6 671-8XE000AX0 P P P P P -

6ES5 734-1BD20

6AV6 671-8XD000AX0 P/D/U P/D/U P/D/U P/D P/D P/D P/D P/D P/D P/D P/D P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U

Ethernet CAT5 P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U -

Changedate: 01.08.2011

This entry is from the Service&Support portal of Siemens AG, Sector Industry, Industry Automation and Drive Technologies. The general terms of use (http://www.siemens.com/terms_of_use) apply.

Page: 6/8

s
DP PtP 6XV1 8300Axxx TP 177B 6" color PN/DP P/D TP 270 6" TP 270 10" TP 277 6" OP 73micro OP3 OP 73 OP7 PP OP7 DP OP7 DP12 OP17 PP OP17 DP OP17 DP12 OP 77A OP 77B OP 170B 6" mono DP OP 177B 6" mono DP OP 177B 6" color PN/DP OP 270 6" OP 270 10" OP 277 6" MP 177 6" Touch MP 270 MP 270B 6" Touch MP 270B 10" Touch MP 270B 10" Key MP 277 8" Touch MP 277 8" Key MP 277 10" Touch MP 277 10" Key P/D P/D P/D P P P P P P P P P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P P P P P P P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D DP Standard Standard Profibus -

What transfer options are available in the various operator panels?

Entry-ID: 19109408

DP
(Mobile Panel)

PN (cross cable)
Point to point

PN Ethernet Standard

2)

PN
(Mobile Panel cable)

Conv.
RS422-RS232

Conv.
RS232-TTY (20mA)

90 Winkel
(9 pol. 1:1)

6XV1 4404Axxx P/D

6XV1 8703RH20 P/D

6XV1 4404Bxxx -

6AV6 671-8XE000AX0 P P P P P P P P P P P P P P P P P P P -

6ES5 734-1BD20

6AV6 671-8XD000AX0 P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U P/D/U

Ethernet CAT5

K5)/D5) K /D P/D P/D K5)/D5) K /D P/D P/D P/D P/D P/D P/D P/D P/D P/D
5) 5) 5) 5)

K5)/D5) K5)/D5) P/D P/D K5)/D5) K /D P/D P/D P/D P/D P/D P/D P/D P/D P/D
5) 5)

Changedate: 01.08.2011

This entry is from the Service&Support portal of Siemens AG, Sector Industry, Industry Automation and Drive Technologies. The general terms of use (http://www.siemens.com/terms_of_use) apply.

Page: 7/8

What transfer options are available in the various operator panels?

Entry-ID: 19109408

DP PtP 6XV1 8300Axxx MP 370 12" Touch MP 370 12" Key MP 370 15" Touch MP 377 12" Touch MP 377 12" Key MP 377 15" Touch MP 377 19" Touch Mobile Panel 170 Mobile Panel 177 DP Mobile Panel 177 PN Mobile Panel 277 Mobile Panel 277 (F) IWLAN (betrifft Ethernet Schnittstelle)
1) With gender changer

DP Standard Standard Profibus P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D -

DP
(Mobile Panel)

PN (cross cable)
Point to point

PN Ethernet Standard

2)

PN
(Mobile Panel cable)

Conv.
RS422-RS232

Conv.
RS232-TTY (20mA)

90 Winkel
(9 pol. 1:1)

6XV1 4404Axxx P/D P/D P/D P/D/U P/D/U P/D/U P/D/U D/U6)

6XV1 8703RH20 P/D P/D P/D

6XV1 4404Bxxx P/D P/D -

6AV6 671-8XE000AX0 P P P P P P P P -

6ES5 734-1BD20

6AV6 671-8XD000AX0 P/D/U P/D/U P/D/U P/ D P/D P/ D P/ D -

Ethernet CAT5

P/D P/D P/D P/D P/D P/D P/D P/D P/D P/D -

P/D/U P/D/U P/D/U P/D/U D/U6)

2) By using PN-IRT (with cycle synchronicity) IRT- ability switches are required 3) Only in conjunction with the RS422/232 converter 4) Internal data link to the PLC 5) NE2000 compatible CF Ethernet adapter is required 6) OS-Update via internal Ethernet port of Mobile Panel 277 (F) IWLAN only. Don't via IWLAN!

Changedate: 01.08.2011

This entry is from the Service&Support portal of Siemens AG, Sector Industry, Industry Automation and Drive Technologies. The general terms of use (http://www.siemens.com/terms_of_use) apply.

Page: 8/8

You might also like