Professional Documents
Culture Documents
N/A
ROHC Profile0x0002 No[0]
N/A
ROHC Profile0x0004 No[0]
N/A
ROHC Profile0x0006 No[0]
Expected
Result
2. UE will send ELS UeIndication message or ELS UeCapabilityInformation message to eNodeB according to the configuration in ELS-SIB1, which indicates that UE
is supported UDC function. When UE sends ELS UeIndication message or ELS UeCapabilityInformation message to eNodeB is determined by the parameter
“UDC Capable UE Send ELS-UEInd or ELS-UECap Message Occasion “configured on eNodeB. Whether UE sends ELS UeIndication message or ELS
UeCapabilityInformation message firstly is determined by the parameter “Is UDC Capable UE Send the ELS-UECap Message Occasion” configured on eNodeB.
If the parameter is configured to “Yes”, the UE should send ELS UeCapabilityInformation message.
http://127.0.0.1:8890/document?channelid=2&record=1&resultid=7&presearchword=... 14/12/2021
ZTE LTE FDD UDC Feature Guide Page 17 of 25
As shown in the figure below, UE sends the ELS UeCapabilityInformation message after the RRC Connection Setup message according to the parameter
configuration.
Figure 6-3 UE Sends the ELS UeCapabilityInformation Message after the RRC Connection Setup Message
If the parameter “Is UDC Capable UE Send the ELS-UECap Message Occasion” is configured to “No”, the UE will send the ELS UeIndication message firstly, as
shown in the figure below.
After UE sent the ELS UeIndication message, eNodeB will require UE to send the ELS UECapabilityInformation message, as shown in the figure below.
Figure 6-5 UE Sends the ELS UECapabilityInformation Message to Report the UDC Capability
3. After eNodeB received the ELS UECapabilityInformation message, eNodeB sends the ELS-RRC Connection Reconfiguration message to UE as shown in the
figure below, which carried the UDC configuration.
4. Then UE sends the ELS-RRC Connection Reconfiguration Complete message to eNodeB, as shown in the figure below.
5. The data is compressed in the PDCP layer of UE side. Whether the uplink data is compressed can be shown in the 0xB0B3 LTE PDCP UL Cipher Data PDU
log, as shown in the figure below. If the value of “compressed pdu” is “Yes”, it indicates the uplink data is compressed.
http://127.0.0.1:8890/document?channelid=2&record=1&resultid=7&presearchword=... 14/12/2021
ZTE LTE FDD UDC Feature Guide Page 18 of 25
6. The Qualcomm UE will print the average compressor gain, and the compressor gain is depended on the service type. The UDP service has the highest
compressor gain which is about 90%. The compressor gain of FTP service is less than UDP service. The compressor gain of FTP service is shown in the figure
below.
7. The uplink FTP throughput is 81.6Mbps on UE side in the 20MHz bandwidth when the UDC function is enabled, as shown in the figure below.
Figure 6-10 The Uplink FTP Throughput is 81.6Mbps in the 20MHz Bandwidth when the UDC Function is Enabled
8. The uplink FTP throughput is 53.4Mbps on PDN side in the 20MHz bandwidth when the UDC function is disabled, as shown in the figure below.
Figure 6-11 The Uplink FTP Throughput is 53.4Mbps in the 20MHz Bandwidth when the UDC Function is Disabled
Above all, the UDC function can improve the uplink throughput for the service with high data repetition frequency.
http://127.0.0.1:8890/document?channelid=2&record=1&resultid=7&presearchword=... 14/12/2021