You are on page 1of 82

Buildings Schedule of Rates - 2007 Summary - YEAR Section 1 - BrickLayer/Mason Item No B-001 Description Brick work in 1:5 cement

sand mortar in foundations up to D.P.C. Brick work in 1:8 cement sand mortar 9" thick in super structure ground floor Brick work in 1:8 cement sand mortar 9" thick in super structure 1 st floor Brick work in 1:8 cement sand mortar 9" thick in second floor Brick work in 1:8 cement sand mortar 9" thick in third floor Brick work in 1:5 cement sand mortar 4 1/2" thick walls in ground floor Brick work in 1:5 cement sand mortar 4 1/2" thick walls in first floor Brick work in 1:5 cement sand mortar 4 1/2" thick walls in second floor Brick work in 1:5 cement sand mortar 4 1/2" thick walls in third floor Brick work in 1:5 cement sand mortar 4 1/2" using available brick Brick work in 1:8 cement sand mortar 9" thick or above using available bricks Masonry block work 4" to 4.5" thick in walls in cement sand 1:5 mortar using hollow blocks made of cement sand to the proportion 1:10, confirming to SLS standard. Masonry block work 4" to 4.5" thick in walls in cement sand 1:5 mortar using hollow blocks made of cement sand to the proportion 1:10, confirming to SLS standard. in first floor Masonry block work 4" to 4.5" thick in walls in cement sand 1:5 mortar using hollow blocks made of cement sand to the proportion 1:10, confirming to SLS standard. in second floor Masonry block work 4" to 4.5" thick in walls in cement sand 1:5 mortar using hollow blocks made of cement sand to the proportion 1:10, confirming to SLS standard. in third floor Masonry block work 8" thick in cement sand 1:5 mortar using hollow blocks made of cement sand to a proportion 1:10, confirming to SLS standard. in groundf floor Masonry block work 8" thick in cement sand 1:5 mortar using hollow blocks made of cement sand to a proportion 1:10, confirming to SLS standard. in first floor Masonry block work 8" thick in cement sand 1:5 mortar using hollow blocks made of cement sand to a proportion 1:10, confirming to SLS standard. in second floor Masonry block work 8" thick in cement sand 1:5 mortar using hollow blocks made of cement sand to a proportion 1:10, confirming to SLS standard. in third floor Supplying & fixing vent brick, size up to 16"x8"x4" Unit Cu Rate Rs 17,277.60

Page 1 Of 25

B-002

Cu

16,730.20

B-003

Cu

17,566.70

B-004 B-005

Cu Cu

17,901.30 18,403.20

B-006

Sq

7,186.70

B-007

Sq

7,427.90

B-008

Sq

7,569.40

B-009 B-010

Sq Sq

7,781.60 4,208.50

B-011

Cu

9,056.60

B-012

Sq

6,655.70

B-013

Sq

6,890.80

B-014

Sq

7,022.10

B-015

Sq

7,218.90

B-016

Sq

11,203.20

B-017

Sq

11,684.00

B-018

Sq

11,906.50

B-019

Sq

12,240.40

B-020

No

148.60

Department of Engineering Services - Central Provincial Council

Page 2 Of 25

B-021

R.R masonry in 1:5 cement sand mortar in foundation using available rubble R.R masonry in 1:5 cement sand mortar in foundation R.R masonry in 1:5 cement sand mortar in superstructure Provision of weep holes in retaining walls with 3.5" dia PVC down pipes including metal packing around inner mouth as directed, length of pipe 2ft0" to 3ft6". Provision of weep holes in retaining walls with 3.5" dia PVC down pipes including metal packing around inner mouth as directed, length of pipe 4ft0" to 5ft6". Provision of weep holes in retaining walls with 3.5" dia PVC down pipes including metal packing around inner mouth as directed, length of pipe 6ft0" to 7ft6". Masonry block work 4" to 4.5" thick in walls in cement sand 1:5 mortar using hollow blocks made of cement sand to the proportion 1:10, confirming to SLS standard. in first floor Masonry block work 4" to 4.5" thick in walls in cement sand 1:5 mortar using hollow blocks made of cement sand to the proportion 1:10, confirming to SLS standard. in second floor Masonry block work 4" to 4.5" thick in walls in cement sand 1:5 mortar using hollow blocks made of cement sand to the proportion 1:10, confirming to SLS standard. in third floor Section 2 - Concrete Works

Cu

11,885.30

B-022 B-023

Cu Cu

15,271.50 16,638.90

B-024

No

319.30

B-025

No

420.30

B-026

No

518.80

B-029

Sq

7,235.30

B-030

Sq

7,373.10

B-031

Sq

7,579.90

Item No C-001

Description Mixing and placing Concrete grade 30, Nominal mix 1:1 :2 ( 3/4") , Mixing and placing Concrete grade 25, Nominal mix 1:1 1/2:3 ( 3/4") ,up to first floor Mixing and placing Concrete grade 20, Nominal mix 1:2:4 ( 3/4") ,up to first floor Mixing and placing Concrete 1:2 1/2:5 ( 1") mixing and placing in position using a concrete mixture Mixing and placing Concrete 1:3:6 (1 1/2") mixing and placing in position using a concrete mixture (including fuel/operator/handling) Mixing and placing Concrete grade 30, Nominal mix 1:1 :2 ( 3/4") , in first floor Mixing and placing Concrete grade 30, Nominal mix 1:1 :2 ( 3/4") , in second floor Mixing and placing Concrete grade 30, Nominal mix 1:1 :2 ( 3/4") , in third fllor Mixing and placing Concrete grade 25, Nominal mix 1:1 1/2:3 ( 3/4") ,in first floor Mixing and placing Concrete grade 25, Nominal mix 1:1 1/2:3 ( 3/4") ,in second floor Mixing and placing Concrete grade 25, Nominal mix 1:1 1/2:3 ( 3/4") ,in third floor Mixing and placing Concrete grade 20, Nominal mix 1:2:4 ( 3/4") ,in first floor

Unit Cu

Rate Rs 37,122.60

C-002

Cu

30,567.40

C-003

Cu

27,868.20

C-004

Cu

21,345.60

C-005

Cu

20,698.40

C-006

Cu

38,236.30

C-007

Cu

38,978.70

C-008

Cu

39,721.20

C-009

Cu

31,484.40

C-010

Cu

32,095.70

C-011

Cu

32,707.10

C-012

Cu

28,704.30

Department of Engineering Services - Central Provincial Council

Page 3 Of 25

C-013

Mixing and placing Concrete grade 20, Nominal mix 1:2:4 ( 3/4") ,in second floor Mixing and placing Concrete grade 20, Nominal mix 1:2:4 ( 3/4") ,in third floor Tor steel reinforcement bend to shape laid in position and tied with G.I. wire as directed Mild steel reinforcement bend to shape laid in position and tied with G.I. wire as directed Sawn timber formwork in column in ground floor Sawn timber form works for underside of floor slab Sawn timber form works for underside of floor slab Formwork in portal frames Formwork in lintels and ground concrete works, plinth beams. Work tops, 2" thick 1:2:4(3/4) complete with, reinforcement R6 4" centre and shuttering

Cu

29,261.60

C-014

Cu

29,819.00

C-015

cwt

7,328.30

C-015A

cwt

7,241.30

C-016 C-017 C-018 C-019 C-020

Sqft Sqft Sqft Sq Sq

86.10 76.20 76.20 11,855.90 3,317.40

C-021

Sq

13,051.40

C-022

C-023

8ftx2ftx1ft6ft platform in brick or rubble sides and,8ftx1ftx9" step, 2ft thick 1:2 1/2":5(1"),Concrete topping, all inclusive of two risers,rendered smooth in No 1:3 cement sand in red colour,and polished, providing 3 nos 2" dia G.I. Flag ,posts, complete w Concrete cover slabs 2" thick 1:2:4(3/4) r/f with ,6mm dia MS bars at bottom @ 4" centre. both ways, finished Sq.ft smooth and neat sides, pre-cast in, pieces not exceeding 2ftx1"6" placed in position as directed, providing drain holes if required. Concrete catch pits valve chambers in 2" thick,concrete sides and internal sides cement rendered smooth, to be leak proof, with provision for necessary pipe connection/passage, with suitable cover or grating on top to be in flush with floor level, interna Concrete catch pits, valve chambers in 2" thick concrete sides and internal sides cement rendered smooth, to be leak proof, with provision fornecessary pipe connection/passage, with suitable cover or grating on top to be in flush with floor level, interna Concrete catch pits, valve chambers in 2" thick concrete sides and internal sides cement rendered smooth, to be leak proof, with provision for necessary pipe connection/passage, with suitable cover or grating on top to be in flush with floor level, intern Drain 9"X6" concrete 1:2 1/2:5 (1") 3" thick expansion joints at 10ft crs 1/2" thick , 1:3 cement sand rendering finish smooth, including neccessary excavation form work, laying polythene membrane and laid to required slope Drain 9"X12" concrete 1:2 1/2:5 (1") 3" thick expansion joints at 10ft crs 1/2" thick , 1:3 cement sand rendering finish smooth, including neccessary excavation form work, laying polythene membrane and laid to required slope Drain 9"X18" concrete 1:2 1/2:5 (1") 3" thick expansion joints at 10ft crs 1/2" thick , 1:3 cement sand rendering finish smooth, including neccessary excavation form work, laying polythene membrane and laid to required slope

22,005.50

125.50

C-024

No

332.50

C-025

No

430.60

C-026

No

920.00

C-027

L.ft

275.20

C-028

L.ft

374.50

C-029

L.ft

431.30

Department of Engineering Services - Central Provincial Council

Page 4 Of 25

C-030

2ft 6" ramp and 9"X6" Drain 1:2 1/2:5(1") concrete 3" thick with 1:3 plaster finish smooth,including neccessary excavation,form work,providing expansion joints at 10ft centers and laying polythene sheet

L.ft

501.40

C-031

C-032

Readymixed concrete grade 20 slump 12 pumped to required level with a concrete pumping machine , rate Cu.m including placing the concrete, porker vibrating the concrete, levelling the concrete and curing the concreting Tor steel reinforcement bend to shape laid in position and tied with G.I. wire as directed in ground floor to first cwt floor Tor steel reinforcement bend to shape laid in position and tied with G.I. wire as directed in first floor to second floor Tor steel reinforcement bend to shape laid in position and tied with G.I. wire as directed in second floor to third floor Section 3 - Demolisher cwt

10,551.90

7,511.50

C-033

7,694.70

C-034

cwt

7,877.90

Item No D-001

Description Ceiling asbestos removing including timber framework, stacking serviceable materials and debris cleared away Ceiling, existing removed materials stacked and debris cleared in two storyed building Doors, windows, partitions, weld mesh, shelving removed from existing walls and stacked 9" Drain cement and sand bricks, demolished and debris cleared Floor paving brick, concrete or rubble inclusive of rendering and debris cleared away Corrugated sheets, iron, asbestos or aluminium alloy removed from Roof including fame work inclusive of wiring and fixtures, gutters, valance boards etc.. in single story buildings Corrugated sheets, iron, asbestos or aluminium alloy removed from Roof including fame work inclusive of wiring and fixtures, gutters, valance boards etc.. in two storeyed buildings Corrugated sheets, iron, asbestos or aluminium alloy removed from Roof including fame work inclusive of wiring and fixtures, gutters, valance boards etc.. in three storeyed buildings Roof removing tile with fame work inclusive of wiring and fixtures, gutters, valance boards etc., stacking and clearing debris in in single storey buildings Tiles calicut or half round , removed from roof of single storey buildings including stacking and clearing debris Roof removing tiles with fame work inclusive of wiring and fixtures, gutters, valance boards etc.. ,stacking and clearing debris in two storeyed buildings.

Unit Sq

Rate Rs 1,399.20

D-002

Sq

1,498.70

D-003

Sq

588.80

D-004

L.ft

17.60

D-005

Sq

540.00

D-006

Sq

479.00

D-007

Sq

513.70

D-008

Sq

548.50

D-009

Sq

1,313.30

D-010

Sq

270.00

D-011

Sq

834.30

D-012

Tiles calicut or half round , removed from roof of two Sq storeyed buildings including stacking and clearing debris Roof removing tiles with fame work inclusive of wiring and fixtures, gutters, valance boards etc., stacking and clearing debris in three storeyed buildings and above. Tiles calicut or half round , removed from roof of three storeyed buildings and above, including stacking and clearing debris

417.20

D-013

Sq

1,313.30

D-014

Sq

556.20

Department of Engineering Services - Central Provincial Council

Page 5 Of 25

D-015 D-016 D-017 D-018 D-019

Truss steel or timber 20 ft. span Truss steel or timber 25 ft. span Truss steel or timber 30 ft. span Walls bricks 4 1/2" thick inclusive of plaster and any fixtures Walls bricks above 9" thick inclusive of plaster and any fixtures Rubble masonry in cement, demolished, rubble stacked and debris removed inclusive of plaster and any fixtures Reinforced concrete Walls, beams or slabs up to first floor Reinforced concrete Walls, beams or slabs up to 2nd floor Reinforced concrete Walls, beams or slabs up to 3rd floor Door or window size up to 40Sq ft removed from existing walls and stacked Door or window size over 40Sq ft removed from existing walls and stacked Door or window sash only size up to 40Sq ft removed from existing walls and stacked Door or window sash only size over 40Sq ft removed from existing walls and stacked Gutters, down pipes, valley GI or PVC including fixtures removed cleaned and stacked. Boards, valance and barge removed cleaned and stacked. Low-level suits, squatting pans removed and stacked. wash basins, cisterns, sinks, urinals removed and stacked. Ridges, asbestos or tile, removed cleaned and stacked. Pipes PVC, GI, removed cleaned and stacked. Rendering, cement, chipped and debris cleared away from brick walls and floors Rendering, cement, chipped and debris cleared away from cement concrete floors and walls Fence uprooted, barbed wire 5 strands rolled up and all materials stacked (Length of fencing to be measured) Tiled, glazed demolished and debris cleared Section 4 - Excavator

No No No Sq Cu

1,139.40 1,424.30 1,709.10 1,112.40 1,390.50

D-020

Cu

1,729.70

D-021 D-022 D-023

Cu Cu Cu

11,372.40 11,678.90 12,533.40

D-024

No

540.00

D-025

No

810.00

D-026

Sq

660.00

D-027

Sq

990.00

D-029

L.ft

4.60

D-030 D-031 D-032 D-033 D-034

L.ft No No L.ft L.ft

3.50 221.40 138.40 6.70 2.20

D-035

Sq

622.70

D-036

Sq

933.80

D-037

L.ft

26.30

D-038

Sq

1,107.00

Item No E-001

Description De-watering during construction in work under water table, for plaster work.

Unit Sq

Rate Rs 648.00

Department of Engineering Services - Central Provincial Council

Page 6 Of 25

E-002

Earth excavation in levelling site inclusive of haulage up to 100 yds. (manual cutting only up to 150 cbs) Earth excavation in levelling site inclusive of haulage up to 100 yds. (machine cutting only) in ordinary soil Excavation in foundations in normal earth up to depth of 5ft0" inclusive of backfilling, compacting and disposal of surplus earth. Excavation in foundations in soft rock requiring manual digging, up to depth of 5ft0" inclusive of backfilling and disposal of surplus materials. Excavation in levelling site in hard rock involving blasting inclusive of haulage up to 100 yds., and piling rubble, extra over earth excavation payable on rubble measurement only. Excavation in levelling site in soft rock involving manual digging inclusive of haulage up to 100 yds.

Cu

850.00

E-003

Cu

290.90

E-004

Cu

1,255.00

E-005

Cu

1,680.00

E-006

Cu

2,210.20

E-007

Cu

1,660.00

E-008

E-009

Excavation in WELLS / PITS in normal earth up to depth of 5 ft 0" inclusive of backfilling behind wall/ ring Cu and disposal of surplus earth, RATE INCLUDE FOR shoring. Excavation in WELLS / PITS in normal earth 5ft 0" to 10ft0" depth inclusive of backfilling behind wall/ring and Cu disposal of surplus earth, RATE INCLUDES FOR shoring Excavation in WELLS / PITS in normal earth 10ft 0" to 15ft0" depth inclusive of backfilling behind wall/ring and Cu disposal of surplus earth, RATE INCLUDES FOR shoring Excavation in WELLS / PITS in normal earth 15ft 0" to 20ft0" depth inclusive of backfilling behind wall/ring and Cu disposal of surplus earth, RATE INCLUDES FOR shoring Filling earth and compacting 6" layers in large quantities, rate includes for transport 100 yds. Filling earth and compacting 6" layers under floors, rate includes for transport 100 yds. Shoring for excavations below water table. Wells bailed out and cleaned total depth up to 10ft0"(measured, capacity of well below water table) Wells bailed out and cleaned total depth up to 18ft0"(measured, capacity of well below water table) Wells bailed out and cleaned total depth up to 25ft0"(measured, capacity of well below water table) Extra over excavation for removing boulders size exceeding 2cft.,in any manner (volume of each boulder measured as 0.75xaverage breadth squared x length) Haulage of earth more than 100 yards away from site deposited and spread by any means. Levelling ground to required grading cutting lumps and spreading and compacting manually. Disposal of surplus earth, inclusive of loading and unloading and transport up to 5 km Cu

1,390.00

1,930.00

E-010

2,740.00

E-011

3,570.00

E-012

985.00

E-013

Cu

1,140.00

E-014

Sq

2,956.10

E-015

1000gl

675.00

E-016

1000gl

1,350.00

E-017

1000gl

1,890.00

E-018

Cu.ft

27.00

E-019

Cu

337.50

E-020

Sq

108.00

E-021

Cu

592.30

E-022

Compacting Gravel filled in 6" layers by manual tamping Cu as specified. (Available gravel at site)

816.00

Department of Engineering Services - Central Provincial Council

Page 7 Of 25

E-023

River sand supplied and spread in layers as specified under foundations, drainage sand blankets, filters, around soakage pits, wells etc. Compacting Gravel in 6" layers by any means except manual tampering as specified. ( gravel available at site)

Cu

4,147.20

E-024

Cu

370.00

E-025 E-026

Rock excavation in column of wall foundation ( 4ft x 4ft x Cu 2ft) Sand filling ( cushion ) under foundation Section 5 - Flooring/Paving Cu

5,073.20 4,237.90

Item No F-001

Description Floor - brick 3" thick, 1:3 cement rendered with expansion joints 3/8" thick filled in 1:2 bitumen sand. ( rate including for curing) Floor - brick 3" thick, 1:3 cement rendered with expansion joints 3/8" thick filled in 1:2 bitumen sand rate including for curing, extra over on colour cement for rendering .( rate including for curing) Floor - brick 3" thick, 1:3 cement rendered with expansion joints 3/8" thick filled in 1:2 bitumen sand rate including for curing , bricks available. Floor concrete 1:2 1/2:5(1") 3" thick 1:3 cement rendered with expansion joints 3/8" thick filled in 1:2 bitumen sand, rate including for curing, compacting ground and laying polythene sheet under the concrete. Floor concrete 1:2 1/2:5(1") 3" thick with expansion joints 3/8" thick filled in 1:2 bitumen sand rate including for curing, compacting ground and laying Floor paved with approved cement pressed tiles on 1:3 cement mortar joints filled with cement grout of matching colour. (concrete base measured separately) Floor paved with approved pattern and colour ceramic floor tiles on 1:3 cement mortar, joints filled with cement grout of matching colour. concrete base measured separately) Floor re- rendered 1:3 cement sand after demolition and clearance of the damaged areas, providing expansion joints 3/8" thick filled in 1:2 bitumen sand ( rate including for curing) Floor rendered 1:3 cement sand with expansion joints 3/8" thick filled in 1:2 bitumen sand ( rate including for curing) Floor rendered 1:3 cement sand with expansion joints 3/8" thick filled in 1:2 bitumen sand in approved colour cement. ( rate including for curing) Extra over rendering, for colour cement waxing and polishing. Tiles glazed of approved pattern and colour with all specials supplied and fixed to walls including raking plaster and bedding in cement mortar 1:3.Joints finished with cement grout of matching colour. Waterproofing in upper floor bathrooms, water tanks etc. with, cementitious water proofing material (Baraelastic) two coats applied on the sloping bed Section 6 - General/Misce

Unit Sq

Rate Rs 9,140.20

F-002

Sq

325.70

F-003

Sq

8,131.80

F-004

Sq

8,131.40

F-005

Sq

5,017.60

F-006

Sq

12,006.30

F-007

Sq

16,531.00

F-008

Sq

2,585.00

F-009

Sq

3,160.30

F-010

Sq

3,304.50

F-011

Sq

1,356.00

F-012

Sq

18,358.80

F-013

Sq

9,729.60

Item No G-001

Description Clearing jungle along the fence

Unit L.ft

Rate Rs 5.40

Department of Engineering Services - Central Provincial Council

G-002 G-003 G-004 G-005 G-006 G-007 G-008 G-009 G-010 G-011 G-012 G-013

Cutting coconut trees removing root ball and stacking logs. Cutting coconut trees removing stumps to ground cutting trees girth 1ft 6" to 3ft 0", removing rootball and stacking logs. cutting trees girth 1ft 6" to 3ft 0",stacking logs. cutting trees girth 3ft 1" to 4ft 6", removing rootball and stacking logs. cutting trees girth 3ft 1" to 4ft 6",stacking logs. cutting trees girth 4ft7" to 6ft0", removing rootball and stacking logs. cutting trees girth 4ft7" to 6ft0",stacking logs. cutting trees girth 6ft1" to 7ft6", removing rootball and stacking logs. cutting trees girth 6ft 1" to 7ft 6",stacking logs. cutting trees girth 7ft7" to 9ft0", removing rootball and stacking logs. cutting trees girth 7ft7" to 9ft0",stacking logs. Fence barbed wire 5 strands 12 1/2 BWG with 4 points at 3" crs and R.C.C posts 1:2:4 (3/4") 5ft7" high, R/F with 4 nos 1/4" rods with 14 BWG stirrups at 8ftcrs, cement concrete foundations 1:3:6(1 1/2")to corner posts and struts and straighteningbolts all Fence barbed wire 8 strands 12 1/2 BWG with 4 points at 3" crs and R.C.C posts 7ft6" high fixed at 8ftcrs, cement concrete foundations 1:3:6(1 1/2") to corner posts and struts and straightening bolts all as per type plan, the struts to be r/f with 4 nos Fence posts intermediate, or struts, cement concrete 1:1 1/2:3(3/4") r/f with 4 nos 6mm msrods and 14 BWG wire stirrups @ 4"crs.,5ft7" high and section 6"x6" bottom and 4"x4" top, as per drawing Fence posts intermediate, or struts, cement concrete 1:1 1/2:3(3/4) r/f with 4 nos 6mm ms rods and 14 BWG wire stirrups @ 4"crs.,7ft6" high and section6"x6" bottom and 4"x4" top, as per drawing Fence posts RC ,available, re fixed rate to include for concreting where necessary. Fence wire barbed 12 Gauge 4 points, available. strengthened and fixed on existing concrete or timber posts. Fence wire barbed 12 Gauge 4 points, supplied and fixed on existing concrete or timber posts. Flight of steps in 1:2 1/2 :5(1") concrete overallwidth 5ft0", waist 4" on well compacted ground,waist below ground level, curb walls 6" thickoverall height 1ft6" in outer surface, rateincludes all formwork and rendering exposedsurfaces 1:3 , size of step Landing in flight of steps 5ft0" wide overall base4" thick, curb walls 6"thick and 1ft6" height externally, in1:2 1/2:5(1) concrete, cement rendered 1:3. Chain link mesh fence 7ft high for 50ft Supply and laying 1.5mX 1.0m X 1.0m Gabion boxes

Page 8 Of 25

No No No No No No No No No No No No

1,953.00 1,386.00 3,116.40 1,971.60 4,515.60 3,370.80 6,487.20 5,191.20 8,775.60 7,663.20 10,691.40 9,579.00

G-014

L.ft

150.40

G-015

L.ft

160.10

G-016

No

824.50

G-017

No

860.60

G-018

No

69.50

G-019

L.ft

2.90

G-020

L.ft

5.70

G-021

L.ft

1,657.60

G-028

L.ft

1,388.90

G-030 G-031

Sqft No

203.60 6,567.50

Department of Engineering Services - Central Provincial Council

Page 9 Of 25

G-032 G-033

Supply and laying 2.0mX 1.0m X 1.0m Gabion boxes Supply and laying 1.0mX 1.0m X 1.0m Gabion boxes

No No

8,898.60 4,694.30

G-034

Supplying and laying Geo textile layer behind the gabion Sq.m retaining wall type T.S. 30 Section 7 - Health & Sewer

302.20

Item No H-001 H-002

Description Elbow pvc 4" supplied and fixed Bend PVC 4" supplied and fixed ,tye 400 Drains laid pvc 4" (type 400) Supplied and laid in medium soil, joints embedded in 1:3:6 (1 1/2") concrete including necessary excavation, back filling, and compeltion invert depth to 2ft to 3ft Drains laid pvc 4" (Type 400) supplied and laid in medium soil,joints embedded in 1:3:6(2) concrete including necessary excavation,back filling and compaction, invert depth up to 2ft0" Drains laid PVC 6" (Type 1000) in medium soil joints embedded in 1:3:6(2) concrete,including necessary excavation,backfilling and completion, invert depth 2ft0" to 3ft0" Drains laid PVC 6" (Type 1000) in medium soil joints embedded in 1:3:6(2) concrete,including necessary excavation,backfilling and completion, invert depth up to 2ft Gully PVC 6" supplied and fixed including concreting and supplying necessary grating. Manhole 2ftx2ftx2ft internally complete with ct concrete 1:2:4 in 3" thick base, cooping on top opf brick walls channelling and bending, walls 9" brick, 1:3 cement rendered 3" thick RC. cover r/f 10mm tor @ 6"cc. both ways, complete with lifting handles. Manhole 2ft x2ft internally complete with ct concrete 1:2:4 in 3" thick base, cooping on top opf brick walls channelling and bending, RCC 1:2:4 in 2" thick cover slab R/f,walls 9" brick, 1:3 cement rendered,extra over for each additional depth Manhole 3ft 6"x2ft3"x2 ft internally with ct concrete 1:2:4 in 3" thk base ,channelling, walls 9" brick, 1:3 cement rendered 3" thick RC. cover r/f 10mm tor @ 6"cc. both ways, complete with lifting handles. Manhole 3ft 6"x2ft 3"internally with concrete base ,channeling, walls 9" brick, 1:3 cement rendered 3" thick RC. cover r/f 10mm tor @ 6"cc. both ways, complete with lifting handles.extra over each additional depth Shallow drains in floors 3" diameter in ct concrete 1:2:4, 3" thick in bottom and sides including ct rendering Soakage pit 4ft diameter internal fully built type invert depth level of 3ft0", raised 6" above ground level complete with RC cover as per type plan.CP/K/119/91A Soakage pit 4ft diameter internal semi built type, built up from invert depth level of 3ft0" raised 6" above ground level complete with RC cover as per type plan.CP/K/119/91A T, pvc 4" supplied and fixed Soakage pit 6ft diameter internal fully built type invert depth level of 3ft0", raised 6" above ground level complete with RC cover as per type plan CP/K/253/92A

Unit No No

Rate Rs 397.30 513.10

H-003

L.ft

98.30

H-004

L.ft

85.70

H-005

L.ft

239.90

H-006

L.ft

216.80

H-007

No

304.80

H-008

No

6,839.50

H-008A

L.ft

1,783.00

H-009

No

10,460.10

H-010

L.ft

2,365.00

H-011

L.ft

179.80

H-012

No

44,048.20

H-013

No

22,762.70

H-014

No

414.80

H-015

No

56,494.10

Department of Engineering Services - Central Provincial Council

H-016

Vent pvc 4" diameter (type 400) fixed on walls with timber plugs and pvc brackets. (Specials paid separately) Construction of septic tanks for 15 persons 7ft X 2ft 6" internally As per detail drawing No. CP/K/117/91A Construction of septic tanks for 25 persons 8ft X 2ft 6" internally As per detail drawing No. CP/K/117/91A Septic tank for 25 persons as per type plan complete, extra over for invert depth exceeding 2ft to 6ft , per each additional foot.

Page 10 Of 25

L.ft

89.10

H-016A

No

47,655.70

H-017

No

51,726.00

H-018

No

4,687.20

H-019

Septic tank for 50 persons invert depth up to 2ft6" complete as per Type plan No:CP/K/121/91A. Septic tank for 50 persons as per type plan complete, extra over for invert depth exceeding 2ft to 6ft, per each additional foot. Septic tank for 100 persons invert depth up to 7ft6" complete as per Type plan No:CP/K/121/91A. Septic tank for 100 persons as per type plan complete, extra over for invert depth exceeding 2ft to 6ft, per each additional feet. Section 8 - Electrical

No

68,420.60

H-020

L.ft

5,440.40

H-021

No

98,538.00

H-022

L.ft

7,651.20

Item No I-001

Description Lamp point wiring

Unit No

Rate Rs 657.80

water tight lamp point wiring I-002 No 633.80

I-003 I-004 I-005

Indoor bracket lamp point wiring Stairway lamp point wiring Ceiling fan point wiring complete with fan hook 5 A.M.P. socket outlets

No No No

726.80 1,295.00 831.00

I-006

No

794.70

I-007 I-008

13 .A.M.P. socket outlets 15 A.M.P Socket out let 15 A.M.P. switch socket outlet c/w 20A D.P. switch with neon indicator lamp Lamp point wiring

No No

1,049.90 1,132.50

I-009

No

1,794.30

I-010

No

633.60

I-011 I-012 I-013 I-014

Water tight lamp with point wiring Indoor bracket lamp point Stairway lamp point Ceilling fan point wiring complete with fan hook

No No No No

633.60 684.90 1,244.00 1,115.30

Department of Engineering Services - Central Provincial Council

Page 11 Of 25

I-015 I-016 I-017

5 AMP soket out let 13 AMP soket out let 15 AMP soket outlet 2 Way SP x N Distribution Board complte with 30 AMP 2P M.C.B. and R.C.C.B. 4 Way SP x N Distribution Board complte with 30 AMP 2P M.C.B. and R.C.C.B. 6 Way SP x N Distribution Board complte with 30 AMP 2P M.C.B. and R.C.C.B. 8 Way SP x N Distribution Board complte with 30 AMP 2P M.C.B. and R.C.C.B. 10 Way SP x N Distribution Board complte with 30 AMP 2P M.C.B. and R.C.C.B. 12 Way SP x N Distribution Board complte with 30 AMP 2P M.C.B. and R.C.C.B. 2 Way SP x N Distribution Board complte with 60 AMP 2P M.C.B. and R.C.C.B. 4 Way SP x N Distribution Board complte with 60 AMP 2P M.C.B. and R.C.C.B. 6 Way SP x N Distribution Board complte with 60 AMP 2P M.C.B. and R.C.C.B. 8 Way SP x N Distribution Board complte with 60 AMP 2P M.C.B. and R.C.C.B. 10 Way SP x N Distribution Board complte with 60 AMP 2P M.C.B. and R.C.C.B. 12 Way SP x N Distribution Board complte with 60 AMP 2P M.C.B. and R.C.C.B. Supplying and Installation of 2 way SPxN Distribution Board complte with 60 AMP, 4P, M.C.B. and 2 Nos 32A, 3P, M.C.B. in surface mount plastic enclosure Supplying and Installation of 4 way SPxN Distribution Board complte with 60 AMP, 4P, M.C.B. and 4 Nos 16A, 3P, M.C.B. type 3 in surface mount metal enclosure Supplying and Installation of 2 way TP/N Distribution Board complte with 100 AMP, 4P, M.C.B. and 2 Nos 30/60AMP, 3P, M.C.B. in surface mount metal enclosure Supplying and Installation of 4 way TP/N Distribution Board complte with 125 AMP, 4P, M.C.B. and 4 Nos 30/60AMP, 3P, M.C.B. in surface mount metal enclosure Supplying and Installation of 20-100 MP, 4P, M.C.C.B. a in surface mount metal enclosure Supplying and Installation of 30 AMP, 2P, Isolator complete with plastic enclosure Supplying and Installation of 60 AMP, 2P, Isolator complete with plastic enclosure

No No No

838.40 1,024.50 1,105.40

I-018

No

7,103.90

I-019

No

8,177.90

I-020

No

9,371.90

I-021

No

10,355.90

I-022

No

11,579.90

I-023

No

12,443.90

I-024

No

6,044.90

I-025

No

8,700.00

I-026

No

9,684.00

I-027

No

10,668.00

I-028

No

11,892.00

I-029

No

12,756.00

I-030

No

9,468.30

I-031

No

16,682.20

I-032

No

37,290.00

I-033

No

67,476.00

I-034

No

13,950.00

I-035

No

1,808.20

I-036

No

2,318.20

Department of Engineering Services - Central Provincial Council

Page 12 Of 25

I-037

Supplying and Installation of 30 AMP, 4P, Isolator complete with plastic enclosure Supplying and Installation of 60 AMP, 4P, Isolator complete with plastic enclosure Supplying and Installation of 30 AMP, 2P, R.C.C.B. ( 30 MA) complete with plastic enclosure Supplying and Installation of 60 AMP, 2P, R.C.C.B. ( 30 MA) complete with plastic enclosure Supplying and Installation of 40 AMP, 4P, R.C.C.B. ( 30 MA) complete with plastic enclosure Supplying and Installation of 60 AMP, 4P, R.C.C.B. ( 30 MA) complete with plastic enclosure 2 X 1 Sqmm + 2.5 Sqmm Cable 2 X 2.5 Sqmm + 2.5 Sqmm E Cable 2 X 4.5 Sqmm + 2.5 Sqmm E Cable 2 X 6.5 Sqmm + 6.5 Sqmm E Cable 2 X 10 Sqmm + 10 Sqmm E Cable 2 X 16 Sqmm + 16 Sqmm E Cable 2 X 25 Sqmm + 16 Sqmm E Cable 4 X 25 Sqmm + 25 Sqmm E Cable 4 X 4 Sqmm + 4 Sqmm E Cable 4 X 6 Sqmm + 6 Sqmm E Cable 4 X 10 Sqmm + 10 Sqmm E Cable 4 X 16 Sqmm + 16 Sqmm E Cable 4 X 25 Sqmm + 16 Sqmm E Cable 4 X 35 Sqmm + 16 Sqmm E Cable 2 X 1 Sqmm + 2.5 Sqmm Cable 2 X 2.5 Sqmm + 2.5 Sqmm E Cable 2 X 4.5 Sqmm + 2.5 Sqmm E Cable 2 X 6.5 Sqmm + 6.5 Sqmm E Cable 2 X 10 Sqmm + 10 Sqmm E Cable 2 X 16 Sqmm + 16 Sqmm E Cable 2 X 25 Sqmm + 16 Sqmm E Cable

No

2,828.20

I-038

No

3,542.20

I-039

No

3,372.00

I-040

No

4,901.90

I-041

No

5,207.90

I-042

No

6,635.90

I-043 I-044 I-045 I-046 I-047 I-048 I-049 I-050 I-051 I-052 I-053 I-054 I-055 I-056 I-057 I-058 I-059 I-060 I-061 I-062 I-063

Lft Lft Lft Lft Lft Lft Lft Lft Lft Lft Lft Lft Lft Lft Lft Lft Lft Lft Lft Lft Lft

69.00 90.00 123.00 178.00 251.20 494.10 625.80 771.90 230.10 281.10 524.60 686.00 835.30 1,057.20 67.90 88.80 121.80 178.00 251.20 359.60 509.60

Department of Engineering Services - Central Provincial Council

Page 13 Of 25

I-064 I-065 I-066 I-067 I-068 I-069 I-070

4 X 25 Sqmm + 25 Sqmm E Cable 4 X 4 Sqmm + 4 Sqmm E Cable 4 X 6 Sqmm + 6 Sqmm E Cable 4 X 10 Sqmm + 10 Sqmm E Cable 4 X 16 Sqmm + 16 Sqmm E Cable 4 X 25 Sqmm + 16 Sqmm E Cable 4 X 35 Sqmm + 16 Sqmm E Cable

Lft Lft Lft Lft Lft Lft Lft

770.70 229.00 281.10 408.40 569.80 835.30 1,057.20

I-071

Pendent lamp c/w 200mm dia. conical plastic shade and No 60W incandescent bulb Pendent lamp c/w 200mm dia. glass globe and 60W incandescent bulb Water tight bracket lamp c/w 200mm dia. clear acrylic globe and 15W C.F.L. bulb, 4 star rating Indoor bracket lamp c/w 200mm dia. opal white glass globe and 40W incandescent bulb Recessed florecent lamp fittings 1200mm x 600mm, complete with polished aluminium double parabolic louver and 2 x 36 bulb

246.80

I-072

No

1,272.80

I-073

No

1,243.00

I-074

No

1,062.20

I-075

No

4,221.90

I-076

Florecent lamp fittings 1200mm single batten type with 1 No x 36W bulb Florecent lamp fittings 1200mm single totaly encased suspension type with 1 x 36W bulb Florecent lamp fittings 600mm single totaly encased suspension type with 1 x 36W bulb Florecent lamp fittings 1200mm single, complete with prismatic diffuser and 1 x 36W bulb suspension type Florecent lamp fittings 600mm single, complete with prismatic diffuser and 1 x 18W bulb suspension type Florecent lamp fittings 1200mm twin, complete with prismatic diffuser and 2 x 36W bulb suspension type Florecent lamp fittings 1200mm single, industrial type c/w 1 x 36W bulb suspension type Florecent lamp fittings 1200mm twin, industrial type c/w 2 x 36W bulb suspension type Florecent lamp fittings 600mm single, industrial type c/w 18W bulb suspension type Rescessed down light complete with 250 D.A. polish aluminium. Reflector and 20W C.F.L. bulb , 4 strar rating Bulk head lamp water tight c/w 18 W CFL bulb 4 star rating Door Bell No

1,246.40

I-077

1,822.40

I-078

No

1,460.80

I-079

No

1,219.80

I-080

No

979.80

I-081

No

2,161.80

I-082

No

1,459.80

I-083

No

2,881.80

I-084

No

1,279.80

I-085

No

1,351.80

I-086 I-087

No No

1,103.50 450.00

Department of Engineering Services - Central Provincial Council

Page 14 Of 25

I-088

Supplying and Installation of ceiling fan 1400mm dia. complete with 5 speed regulator (Excuding wiring) Supplying and Installation of 200mm dia. Exhust fan with Auto shutter (Excuding wiring) Supplying and Installation of 250mm dia. Wall fan with speed regulator to work order (Excuding wiring)

No

5,299.40

I-089

No

5,761.40

I-090

No

11,053.50

I-091

Supplying and Installation of Earth electrode 20mm dia. 5 feet long to working order complte with forming of gully No around the pipe Supplying and Installation of 5 amp socket outlet Supplying and Installation of 13 amp socket outlet Supplying and Installation of 15 amp socket outlet Section 9 - Joiner No No No

967.50

I-092 I-093 I-094

249.70 256.00 292.50

Item No J-001

Description Barrel bolts 4" brass supplied & fixed Barrel bolts 4" ox. iron supplied & fixed

Unit No

Rate Rs 219.00

J-002

No

126.60

J-003 J-004 J-005 J-006 J-007 J-008 J-008b

Barrel bolts 6" brass supplied & fixed Barrel bolts 6" ox. iron supplied & fixed Butt hinges brass 4"x2 1/2" Butt hinges oxidized iron 4"x2 1/2" Cabin hook 4" to 6" supplied & fixed Casement stays 10" Iron oxidized supplied and fixed. Casement stays 12" Iron oxidized supplied and fixed.

No No Pr Pr No No No

291.00 141.00 656.40 253.40 27.70 148.40 159.20

J-009

J-010

J-011

Collapsible door, iron, open type complete with locking arragment and two coats anticorrosive paint,two coats Sq.ft of enamal paint. Door 1 1/8" thick, battened sash with 3 3/4"x1 3/4" frame, incl.1 timber, oxidized heavy duty furniture 4"x21/2" withinside and out side 4" barrel bolts in lieu of Sq.ft lock andpainted sashes two coats cream enamel paint &frame two coats brown enamel paint, Door 1 1/8" thick battened, sash with 3 3/4"x1 3/4" frame with, inJack/special timber, oxidized heavy duty Sq.ft furniture withbarrel painted sashes two coats cream enamel paint &frame two coats brown enamel paint, Door 1 1/8" thick paneled sash with 3 3/4"x2 3/4" frame,in cl.1 timber, oxidized heavy duty furniture, Union Sq.ft or Yale original morticelock, sashes painted two coats cream and framepainted two coats brown enamel paint allcomplete .(single shash) Door 1 1/8" thick paneled sash with 3 3/4"x2 3/4" frame,in Jack/special timber, oxidized heavy duty Sq.ft furniture, Union or Yale original mortice lock, sashes painted two coats cream and frame painted two coats brown enamel paint all complete .

554.30

470.70

475.50

J-012

795.70

J-013

763.50

Department of Engineering Services - Central Provincial Council

J-014

J-015

J-016

J-017

J-018

J-019

Door 1 1/8" thick paneled & glassed double hungsashes and top fanlight 3 3/4"x2 3/4" frame,cl.1timber,oxidized heavy duty furniture, Union orYale original mortice lock,sashes painted 2coats cream and frame painted 2 coats brownenamel paint all complete Door 1 1/8" thick paneled & glassed double hungsashes and top fanlight 3 3/4"x2 3/4" frame,in Jack/specialtimber,oxidized heavy duty furniture,Union orYale original mortice lock,sashes painted 2coats cream and frame painted 2coats brownenamel paint all Door 1 1/8" thick paneled, with 3 3/4"x1 3/4" frame, in cl.1 timber, oxidized heavy duty furniture with inside and out side 4" bolts in lieu of lock and painted sashes two coats cream enamel paint &frame two coats brown enamel paint, Door 1 1/8" thick paneled, with 3 3/4"x1 3/4" frame, inJack/special timber, oxidized heavy duty furniture withinside and out side 4" bolts in lieu of lock andpainted sashes two coats cream enamel paint &frame two coats brown enamel paint, Door 1 1/8" thick plywood sash with 3 3/4" x 2 3/4" Cl.1timber frame, oxidized heavy duty furniture, Unionor Yale original mortice lock, sashes painted twocoats cream and frame painted two coats brownenamel paint all complete as per Type Door 1 1/8" thick plywood sash with 3 3/4" x 2 3/4" specialtimber frame, oxidized heavy duty furniture, Unionor Yale original mortice lock, sashes painted twocoats cream and frame painted two coats brownenamel paint all complete as per Type... Dr.

Page 15 Of 25

Sq.ft

768.90

Sq.ft

922.40

Sq.ft

601.20

Sq.ft

869.40

Sq.ft

602.50

Sq.ft

570.30

J-020

Door and window frames repaired and re-fixed ,Timber if No used measured separately Door or window sash repaired and re- fixed(timber, except beadings if used measuredseparately) Draw rings 1 1/2" supplied and fixed Glass panes replacing 1/8" clear rate includes for necessary beadings etc. Glass panes replacing 1/8" pinhead ,rate includes for necessary beadings etc. Hasp & staple 4" to 6" supplied and fixed with 2" heavy duty Union padlock Lock rim or night latch (Chinese) supplied & fixed Lock Union or equivalent mortice, supplied & fixed Lock Union or equivalent mortice, supplied & fixedto double hung doors Security weld mesh door sash with lock, in GI weld mesh 2"x2" SWG 10, welded on 40x40x5 mm MSangle frame complete with application of twocoats brown enamel paint over two coats ofanticorrosive paint complete . Security weld mesh in open type buildings in GIweld mesh 2"x2" SWG 10, welded on 40x40x5 mm angle frame complete with application of twocoats brown enamel paint over two coats ofanticorrosive paint complete . Special security grille fixed on aluminium windows complete .(in 18mmx5mm flat iron frame & SWG 10, 50x50mm weld mesh complete with painting as directed ) Special security grille fixed on aluminium windows complete to detail with frame in 18x5mm M.S flats Internal horizontal members in 12x5mm.M.S flat at 4" crs. Properly welded and fixed to walls withrole plugs ,screws inclusive of appl two coats ofblack

132.00

J-021

Sq.ft

66.00

J-022

No

83.70

J-023

Sq.ft

134.20

J-023B

Sq.ft

136.00

J-024

No

597.80

J-025 J-026

No No

369.00 3,196.50

J-027

No

5,710.50

J-028

Sq.ft

417.00

J-029

Sq.ft

261.90

J-030

Sq.ft

198.30

J-030a

Sq.ft

222.00

Department of Engineering Services - Central Provincial Council

Page 16 Of 25

J-031

Timber used in repairing door & window frames ,Class. 1 4"x2"(measured finished work) Timber used in repairing door & window frames ,Class. 1 4"x3".(measured finished work) Timber used in repairing door & window frames ,Jack/special 4"x2".(measured finished work) Timber used in repairing door & window frames ,Jack/special 4"x3".(measured finished work) Timber used in repairing doors & windows , Cl.1up to 1 1/8" thick planks. (measured finished work)

L.ft

167.30

J-032

L.ft

233.30

J-033

L.ft

146.80

J-034

L.ft

199.50

J-035

Sq.ft

291.00

J-036

Timber used in repairing doors & windows, special up to Sq.ft 1 1/8" thick planks. (measured finished work) Window fully glazed 1 1/8" sashes and nominal 100x75mm framein cl 1 timber comp.with oxidized heavyduty furniture,3/16" clr glass,including enamal paint. Window fully glazed 1 1/8" sashes and 3 3/4"x2 3/4" framein Jack/special timber comp.with oxidized heavy duty furniture, 3/16" clr glass,including enamal paint. Casement fasteners Iron oxidized supplied and fixed Door, window frames new, measured length of timberClass. 1, 3 3/4"x 1 3/4" Supplied & fixing. Door, window frames new, measured length of timberClass 1, 3 3/4"x 2 3/4" Supplied & fixing. Door, window frames new, measured length of timber Jack 3 3/4"x 1 3/4" Supplied & fixing. Door, window frames new, measured length of timberJack/special 3 3/4"x 2 3/4" Supplied & fixing. Door, window 1 1/8" thick new sash glassed or paneled cl.1 supplied and fixed (furniture measured separately)

483.40

J-037

Sq.ft

752.10

J-038

Sq.ft

705.70

J-041

No

94.20

J-042

L.ft

149.90

J-045

L.ft

215.90

J-046

L.ft

129.40

J-047

L.ft

182.00

J-048

Sq.ft

244.80

J-049

Door, window 1 1/8" thick sash new glassed or paneled Jack or special supplied and fixed (furniture measured Sq.ft separately) Wicket gate sash in Jack or special timber 1" thick supplied and fixed (furniture measured separately) Sq.ft

244.80

J-050

407.10

J-051

Wicket gate sash in class. 1 timber 1" thicksupplied and Sq.ft fixed (furniture measured separately) Glass panes plane 1/8" replaced complete. Glass panes plane 3/16" replaced complete. Sq.ft Sq.ft

308.10

J-052 J-053

93.70 124.30

J-054

Security weld mesh in open type buildings in GIweld mesh 2"x2" SWG 10, welded on 40x40x5 mm MS angle Sq.ft frame complete with application of two coats brown enamel paint over two coats ofanticorrosive paint to detail of Dr. No.(USING AVAILABLE WELD MESH) Fixing security weld mesh on existing window frames complete with class. 1 timber beadings, andapplying two Sq.ft coats paint to match the exiting. Supply and fix plywood door sash approved quality(Painting & Locks measured separately) Sq.ft

152.10

J-055

77.50

J-056

167.50

Department of Engineering Services - Central Provincial Council

J-057

J-058

Anodized Aluminium hinged type shash door fan light on top with aluminium architectural sections with 10 - 15 Sq.ft micron coating glazed and pannelled with 3mm plastic coated ply board to both sides.At bottom and 5mm thick glass at top. Door size 5 X 8-10 Anodized Aluminium glazed window with openeble sash with aluminium architectural sections with 10 - 15 Sq.ft micron coating glazed 5 mm thick glass including all neccssary rubber beading,rawl plug etc. fan light on top Anodized Aluminium sliding window with aluminium architectural sections with 10 - 15 micron coating glazed Sq.ft with 5 mm thick glass including all neccssary rubber beading,rawl plug etc. (size 4 X 4) Anodized Aluminium partition with aluminium architectural sections with 10 - 15 micron coating glazed and pannelled with 3mm plastic coated plyboard to both Sq.ft sides.At bottom and 5mm thick glass at top. rate for 12ft 9" X 9ft 6" high Section 10 - Painter/Decorator

Page 17 Of 25

771.30

666.10

J-059

734.90

J-060

598.40

Item No P-001 P-001A P-001B P-001C

Description Cement wash to walls of single storeyed building one coat Cement wash to walls 2 coat in single storeyed building Cement wash externally to walls of building with upper floors, 1 coat Cement wash externally to walls of building with upper floors, 2 coat

Unit Sq Sq Sq Sq

Rate Rs 177.00 301.10 203.10 344.90

P-002

Prepare and apply one coat of alkali resisting primer and Sq two coats of emulsion pain to walls Paint emulsion after cleaning and preparing , one coat Painting walls with emulsion paint (2 Coats) Paint enamal after cleaning and preparing , new Wood work inclusive of primar undercoat. two coats Paint enamal after cleaning and preparing , one coat Paint enamal after cleaning and preparing , two coats Paint removed to bare timber with blow lamp Painting steel work anticorrosive paint after removing scales and wirebrushing, one coat Painting steel work anticorrosive paint after removing scales and wirebrushing, two coat Snowcem applied to wall surfaces one coats Snowcem applied to wall surfaces two coats Varnishing two coats with copal varnish after sand papering Varnish Polyurethene applied to timber surfaces old work, one coat Weathershield paint one coat applied on external surfaces. Weathershield paint two coats applied on external surfaces. Sq Sq

2,312.90

P-003 P-004

632.80 1,348.90

P-005

sq

3,311.70

P-006 P-007 P-008

Sq Sq Sq

1,199.30 2,992.00 830.30

P-009

Sq

1,204.40

P-010

Sq

1,824.70

P-011 P-012 P-013 P-014 P-015 P-016

Sq Sq Sq Sq Sq Sq

817.50 1,295.10 1,807.50 1,195.40 728.10 1,361.20

Department of Engineering Services - Central Provincial Council

Page 18 Of 25

P-016A

Prepare and apply one coat of primer and two coats of weatheshild paint for new walls White or colour washing to walls, in two storeyed building one coat White or colour washing to walls after patching up and preparing surface one coat White or colour washing to walls after scraping to original plaster including patching up, two coats White washing to ceiling one coat White washing to ceiling two coat Section 11 - Roofer

Sq

2,414.30

P-017

Sq

96.30

P-018

Sq

192.70

P-019

Sq

382.60

P-020 P-021

Sq Sq

236.30 409.60

Item No R-001

Description Supplying and fixing new Asbestos roofing sheets confirming to SLS 9 on existing framework with new nut and bolts etc.(Frame work Measured Separately) Asbestos roofing sheets replacing with new sheets Ceiling 3/4" thick Lunumidella, tongued and grooved under side of rafters ,on existing timber frame work Ceiling, asbestos, flat fixed with clout headed nails to 4"x2" joists & 2" X 2" bearers of cl. 1 timber including 1 1/2" x 1/2" cover fillets & 2 1/2"x 1 1/2" coves of approved timber.Rate to include 2 coats of emulsion underside of ceiling Ceiling, asbestos, flat fixed with clout headed nails to 4"x2" joists & 2" bearers of cl. 1 timber including 1 1/2" x 1/2" cover fillets & 2 1/2"x 1 1/2" coves of approved timber.Rate to include 2 coats of wood preservatives applied on joists and bearers Ceiling flat asbestos under side of rafters ,timber frame work measured seperately,rate includes for clout headed nails ,screws,beadings and mouldings. Ceiling flat asbestos under side of steel purlins ,2"x2" Cl 1timber frame not more than 4ftx2ft crs.includes for clout headed nails ,screws,beadingsand mouldings and r6 steel hanging hooks.Rate to include for apllication of wood preservative on timber fra Ceiling flat Lunumidella 3/4" thick tongued and grooved complete with timber frame cl.1 4"x2" joists at 2ft0"crs,Rate to include for apllication of wood preservative on timber frame work twice. (Painting measured separately) Down pipes pvc 3 1/2 " dia supplied and fixedwith brackets at not exceeding 4ft0"well secured to walls with Cl.1 timber plugs ,rates includes for specials Down pipes GI G24, 4" with 3/4"x1/8" hoop iron brackets not exceeding 4ft0" crs. inner side of the pipe applied with two coats hot tar blinded with sand, all other sides andbrackets applied with 2 coats anticorrosive paint, rate includes for special Gutters GI G22, 6" with 1/2"x1/4" flat iron brackets not exceeding 2ft0" crs. inner side ofthe gutter applied with hot tar blinded with sand and allother sides and brackets appliedwith two coats anticorrosivepaint ,rate includesfor specials Gutters pvc squre type 6"ftwith pvc brackets not exceeding at 9" Bracket fixed to valance board using 3/4" brass screws,rate includes for specials. Plaster bands in 1:1:5 cement lime sand to tiled roof coloured to match

Unit Sq

Rate Rs 4,869.20

R-002

Sq

5,409.20

R-003

Sq

6,888.90

R-004

Sq

14,735.70

R-005

Sq

13,474.70

R-006

Sq

7,237.40

R-007

Sq

13,090.70

R-008

Sq

16,903.30

R-009

L.ft

87.60

R-010

L.ft

209.50

R-011

L.ft

171.60

R-012

L.ft

161.00

R-013

L.ft

10.10

Department of Engineering Services - Central Provincial Council

R-014

Ridging asbestos close fiting type fixed with necessary bolts. Ridging calicut patern tile bedded in cement and lime motar 1:1:4 coloured to match tiles Steel sections 2/ 62x62x6mm used in gable rafters purlins etc.complete with fixing,bolts,anticorrosive paint,and providing cleats where necessary .(concrete pad paid separately) Wood preservative applying one coat on roof structure in asbestos roof measured in plan area Wood preservative applying one coat on roof structure for calicut tile roof, measured in plan area Wood preservative applying two coats on roof structure for asbestos roof measured in plan area Wood preservative applying two coats on roof structure for calicut tile roof measured in plan area Tiles calicut available laying on roof (for scattered laying) upto 10 tiles per building only.

Page 19 Of 25

L.ft

155.20

R-015

L.ft

100.60

R-019

L.ft

589.70

R-020

Sq

302.70

R-021

Sq

505.40

R-022

Sq

605.40

R-023

Sq

963.20

R-024

No

27.00

R-025

Tiles calicut new supplying and laying ( scattered laying) No upto 25 tiles per building only. Tiles calicut shifting and relaying after cleaning(for measurements of area exceeding 25 tiles) Tiles, calicut pattern,supplied and laid in anybuilding Timber 2"x1" reepers class 1 replacing with new including application of two coats wood preservative ( only up to .5 sq of roof area) Timber 2"x1" reepers class 1 supplied and fixed including application of two coats woodpreservative ( only up to .5 sq of roof area) Timber 2"x2" battons class 1 replacing with new including application of two coats woodpreservative ( only up to .5 sq of roof area) Timber 2"x2" battons class 1 supplied and fixed including application of two coats woodpreservative ( only up to .5 sq of roof area) Timber 2"x4" joists / rafters class 1 replacing with new including application of two coats woodpreservative ( only up to .5 sq of roof area) Timber 2"x4" joists / rafters class 1 supplied and fixed including application of two coats woodpreservative ( only up to .5 sq of roof area) Timber beams,any size class 1 suppliedand fixed including application of two coats woodpreservative ( only up to .5 sq of roof area) Timber boarding cl.1, 3/4" to 1" thick for valley gutters, flashings etc inclusive of two coats wood preservative ( only up to .5 sq of roof area) Valance boards beaded 9"x3/4" thick supplying and fixing Class 1 timber, including two coats enamal paint . Valance boards beaded 9"x3/4" thick supplying and fixing Ginisapu mango , including two coats enamal paint . Valley gutters and flashing in GI sheets G22, including application of two coats hot tar and blinding with sand ( timber board measured seperately) 3ft wide

35.30

R-026

No

10.80

R-027

Sq

4,155.00

R-028

L.ft

15.70

R-029

L.ft

14.90

R-030

L.ft

42.90

R-031

L.ft

42.40

R-032

L.ft

125.00

R-033

L.ft

122.80

R-034

Cu.ft

2,095.30

R-035

Sq.ft

141.20

R-036

L.ft

836.80

R-036A

L.ft

813.90

R-037

L.ft

231.70

Department of Engineering Services - Central Provincial Council

Page 20 Of 25

R-038

Ridge tiles available laid on roof on 1:3cement sand bedding coloured to match Timber available,cleaned and fixed on roof,size 2"x1" Timber available,cleaned and fixed on roof,size 2"x2" Timber available,cleaned and fixed on roof,size 4"x2" Timber available,cleaned and fixed on roof,size 4"x3" Timber available,cleaned and fixed on roof,size 5"x2" Roof trusses available cleaned and placed inposition with supplying necessary bolts and templates, 20 to 24 ft spans. Roof trusses available cleaned and placed inposition with supplying necessary bolts and templates, 25 to 29 ft span Roof trusses available cleaned and placed inposition with supplying necessary bolts and templates, 30 ft and above up to 40ft span Fixing available steel purlins on roofs tructures complefte with necessary bolts,welding, cleaning and painting two coats anticorrosive paints etc. Roof asbestos. 62x62x6mm MS purlins not exceeding 4ft6" crs.complete with necessary bolts / welds GI roofing bolts atnot more than 22" crs. on every purlin, applied with two coats anti corrosivepaint and the underside of sheets appliedwith two Laminated aluminium foil, single side 8mm tk. without insulation layer, supplied and laid under the roof. as directed. Laminated aluminium foil,double side 8mm tkwith insulation layer, supplied and laid underthe roof as directed. Mineral fibre board ceiling 1/2" thick suspended type with anodized aluminium T and and L sections complete as per detailed drawing.(ALUMINIUM FOIL MEASURED SEPERATELY) Web truss 27ft span pitch 30 degree ( 2ft depth) Roof truss steel 20 ft span S/F Drawing no CP/PC/K141/96/ST. Rate to include for all shop fabrication work,including cutting,drilling,bolting,riverting,welding,grinding, painting 2 coats anticorrosive Roof truss steel 25 ft span S/F Drawing no CP/PC/K141/96/ST. Rate to include for all shop fabrication work,including cutting,drilling,bolting,riverting,welding,grinding, painting 2 coats anticorrosive Roof truss steel 30 ft span S/F Drawing no CP/PC/K141/96/ST. Rate to include for all shop fabrication work,including cutting,drilling,bolting,riverting,welding,grinding, painting 2 coats anticorrosive Roof truss steel 35 ft span S/F Drawing no CP/PC/K141/96/ST. Rate to include for all shop fabrication work,including cutting,drilling,bolting,riverting,welding,grinding, painting 2 coats anticorrosive Roof truss steel 40 ft span S/F Drawing no CP/PC/K141/96/ST. Rate to include for all shop fabrication work,including cutting,drilling,bolting,riverting,welding,grinding, painting 2 coats anticorrosive Section 12 - Surface/Plaster Work

L.ft

68.00

R-039 R-040 R-041 R-042 R-043

L.ft L.ft L.ft L.ft L.ft

5.50 6.10 26.50 26.50 26.50

R-044

No

3,480.00

R-045

No

4,020.00

R-046

No

4,560.00

R-047

L.ft

32.20

R-048

Sq

13,559.00

R-049

Sq

3,383.20

R-050

Sq

4,105.20

R-051

Sq

14,339.70

R-052

cwt

7,506.10

R-053

No

24,019.60

R-054

No

30,550.00

R-055

No

39,031.90

R-056

No

53,969.10

R-057

No

62,451.00

Item No Description Department of Engineering Services - Central Provincial Council

Unit

Rate Rs

Page 21 Of 25

S-001

Black board in 1:3 cement sand including moulding at perimeter 3/4" thick 5/8" thick plastering to wall Cement lime sand 1:1:5 finished smooth with lime putty floating 5/8" thick plastering to wall Cement lime sand 1:1:5 finished smooth with lime putty floating in first floor 5/8" thick plastering to wall Cement lime sand 1:1:5 finished smooth with lime putty floating in second floor 5/8" thick plastering to wall Cement lime sand 1:1:5 finished smooth with lime putty floating in third floor Cement lime sand 1:1:5 finished smooth reveals 1 1/2" to 6" Cement lime sand plaster breaking damaged areas and replastering 1:1:5., 3/4" thick Cement sand 1:3 plaster finished smooth with limeputty on concrete surfaces and soffits, 3/8" thick 5/8" thick Cement sand 1:5 finished rough with wooden float 5/8" thick Cement sand 1:5 finished rough with wooden float Ground floor to first floor 5/8" thick Cement sand 1:5 finished rough with wooden float first floor to second floor 5/8" thick Cement sand 1:5 finished rough with wooden float Second floor to third floor Ct. sand 1:5 finished rough, reveals 1 1/2" to 6" Cement sand rough plaster breaking damaged areas and replastering 1:1:5. Damp proof course 1:2 cement sand trowelled smooth 3/4" thick and two coats hot tar blinded with sand. Plinth plaster 1/2" thick, 1:3 cement sand finished in neat cement Plinth plaster 1:3 cement sand finished in colourcement Rendering cement sand 1:3 ,3/4" thick, finished smooth on walls 1/2 x 6" skirting in cement sand 1:3 projected or flush to walls finished with floating including forming groove Skirting 1:3 finished in colour cement Section 13 - Water Supply/Plumb

Sq

4,703.30

S-002

Sq

3,113.80

S-002A

Sq

3,269.50

S-002B

Sq

3,425.20

S-002C

Sq

3,580.90

S-003

L.ft

31.90

S-004

Sq

3,653.80

S-005

Sq

4,495.80

S-006

Sq

2,519.10

S-007

Sq

2,645.10

S-007A

Sq

2,771.10

S-007B

Sq

2,897.00

S-008

L.ft

25.90

S-009

Sq

3,299.10

S-010

Sq

4,667.40

S-011 S-012 S-013

Sq Sq Sq

2,505.50 2,543.60 3,675.20

S-014

L.ft

52.90

S-015

L.ft

56.70

Item No W-001

Description Supplying & fixing 1/2" dia. Bidet spray ordinary quality Cistern Ceramic low level supplied and fixed including 1//2" flexible hose Cistern plastic English supplied and fixed with 1/2" flexible hose

Unit No

Rate Rs 604.80

W-002

No

2,329.10

W-003

No

2,715.60

Department of Engineering Services - Central Provincial Council

Page 22 Of 25

W-004

Closet pedastal type with low level cistern,flushpipe, double plastic seat cover,1/2" angle valve and flexible hose, supplied and fixed in working order. Semi Luxary, Closet pedastal type with low level cistern,flushpipe, double plastic seat cover,1/2" angle valve and flexible hose., supplied and fixed in working order. Luxuary type,Closet pedastal type with low level cisternflushpipe, double plastic seat cover,1/2" stop cocktrap etc., supplied and fixed in working order. 4 No. Bowl type urinal with trap and 2 gals. capacity automatic flushing cistern and spreaders complete to working order Closet squatting type with trap ,medium size,supplied and fixed in working order includingconnection to sewer line complete with cementfoot rest, rate includes for breaking floor andconcreting and rendering in making damagedareas good. New Closet squatting type with trap ,medium size,supplied and fixed in working order including connection to sewer line complete with cement foot rest. Mirror bathroom 20"x16" approved quality with shelf,screws,plugs etc supplied and fixed Sink stainless steel with single drain board with drain board with chromium plated wastewater chain, stay & waste plug (Tap.brackets, water & waste water connection & b/work measured separately) Sink 24"x15"x7" overall ceramic with 1/2" dia. chromiam plated piller tap,waste plug,chromiam plated waste chain & stay (water supply and waste connection & B/work measured separately) Sink ceramic laboratory supplying and fixing complete with waste and brackets, chromiam plated waste ,chain, stay and waste plug.(Tap, water & waste water connection B/work measured separately) Suppling and fixing Coner wash basin ceramic with 1/2" dia. chromiam plated piller tap,waste plug,chain,stay including pedestal and brackets (Water connection and waste connection measured separately)

No

8,735.40

W-005

No

9,320.40

W-006

No

19,355.40

W-007

No

1,659.70

W-008

No

4,085.50

W-009

No

3,004.70

W-010

No

1,164.70

W-011

No

3,208.50

W-012

No

5,153.30

W-013

No

3,245.30

W-014

No

3,280.50

W-015

Supplying and fixing 22" X 16" glazed fire clay pedastal type wash basin with 1/2" dia. chromiam plated piller tap, waste water plug, chromiam plated waste chain and No stay. Including fixing wash basin on brackets/wooden plug.water and waste water connectio Removing and refixing available wash basin Stand post with 3ftx3ft grade 20 concrete base and 6"x6" rcc pillar,1/2" brass bib tap,heavy quality inclusive of pvc 1/2" pipeconnection , pipe measured seperately. Tank water storage ,400 gl. composite brick and reinforced concrete ,erected at up to 10ft aboveground level.(trestle if any measured seperately)(rate to include for ball valve and connection) Supply and install water tank made of polymermaterials of approved quality on sand bed , 1000 lt capacity ( confirming to SLS 1174) Rate for only water tank. PVC pipe, valve fittings measured separately Supply and install water tank made of polymermaterials of approved quality on sand bed , 2000 lt capacity ( confirming to SLS 1174) Rate for only water tank. PVC pipe, valve fittings measured separately Supply and install water tank made of polymermaterials of approved quality on sand bed , 500 lt capacity ( confirming to SLS 1174) Rate for only water tank. PVC pipe, valve fittings measured separately Supplying & Fixing rubber rings in outlets for Wash basin,Sink, etc No

3,549.10

W-016

1,094.00

W-017

No

3,629.50

W-018

No

34,238.50

W-019

No

13,368.70

W-020

No

22,959.40

W-021

No

7,521.40

W-022

No

108.40

Department of Engineering Services - Central Provincial Council

W-023

Supplying and fixing 1/2" dia. chromiam plated heavy quality swan neck typpe piller tap with 01 No. P.V.C. F/Socket to wash basin/sink Supplying and fixing 1/2" dia. chromiam plated heavy quality piller tap with 01 No. P.V.C. F/Socket to wash basin/sink Supplying and fixing 1/2" dia. brass heavy quality tap with 1/2" dia. P.V.C. valve socket Supplying and fixing 1/2" dia. plastic tap with 1 No. F/socket P.V.C Supplying & fixing 1/2" dia. , 6" shower rose,chromium plated Supplying and fixing 1/2" dia. shower rose best quality Pipes pvc supplied and laid with specials,size 1 1/2" in wastes of sinks. Type 1000 Pipes pvc supplied and laid with specials,size 1 1/2" rate includes for cutting trencthes and backfilling. (type 1000), depth not less than 1ft6". Pipes pvc type 1000 supplied and laid with specials, size 1 1/4" in waste of wash basins. Pipes pvc type 1000 supplied and laid with specials, size 1 1/4" rate includes for cutting trencthes and back filling, depth not less than 1ft6". Pipes pvc supplied and laid with specials,size 1" type 1000 rate includes for cutting trencthes andback filling, depth not less than 1ft to 1ft-6" Pipes pvc supplied and laid with specials,size 1/2" Type 1000 rate includes for cutting trenches and back filling, depth not less than 1ft to 1ft-6" Pipes pvc supplied and laid with specials, size 2" in waste water lines, vent etc. (type 400) Pipes pvc supplied and laid with specials,size 2" Pipes pvc supplied and laid with specials,size 3/4"Type 1000 rate includes for cutting trenches and backfilling, depth 1ft to 1ft 6" Valve chamber 9"x9"x9"in concrete, complete withRCC. lid PVC Elbow supplied and fixed size 1/2" PVC Elbow supplied and fixed size 3/4" PVC Elbow supplied and fixed size 1" PVC Elbow supplied and fixed size 1 1/4" PVC Elbow supplied and fixed size 1 1/2" PVC Elbow supplied and fixed size 2" PVC Bend supplied and fixed size 1/2" PVC Bend supplied and fixed size 3/4"

Page 23 Of 25

No

1,102.50

W-025

No

1,132.50

W-026

No

279.10

W-027 W-028 W-029

No No No

234.50 442.10 808.60

W-030

L.ft

120.50

W-031

L.ft

100.90

W-032

L.ft

72.50

W-033

L.ft

77.00

W-034

L.ft

59.80

W-035

L.ft

36.10

W-036

L.ft

153.00

W-037

L.ft

153.70

W-038

L.ft

48.00

W-039 W-040 W-041 W-042 W-043 W-044 W-045 W-046 W-047

No No No No No No No No No

912.60 34.30 40.20 53.60 70.80 128.40 179.50 39.40 46.70

Department of Engineering Services - Central Provincial Council

Page 24 Of 25

W-048 W-049 W-050 W-051 W-052 W-053 W-054

PVC Bend supplied and fixed size 1" PVC Bend supplied and fixed size 1 1/4" PVC Bend supplied and fixed size 1 1/2" PVC Bend supplied and fixed size 2" PVC Socket supplied and fixed size 3/4" PVC Socket supplied and fixed size 1/2" PVC Socket supplied and fixed size 1"

No No No No No No No

59.30 70.80 166.60 296.30 37.80 21.60 48.80

Department of Engineering Services - Central Provincial Council

Page 25 Of 25

W-055 W-056 W-057 W-058 W-059 W-060 W-061 W-062 W-063 W-064 W-065 W-066 W-067 W-068 W-069 W-070 W-071 W-072 W-073 W-074

PVC Socket supplied and fixed size 1 1/4" PVC Socket supplied and fixed size 1 1/2" PVC Socket supplied and fixed size 2" Gate valve ,Brass, supplied and fixed, size 1/2" heavy quality. Gate valve ,Brass,supplying and fixing, size 1" , heavy quality, Valve gate Brass, supplied and fixed, size 1 1/4" heavy quality. Valve gate Brass, supplied and fixed, size 1 1/2" heavy quality. Valve gate Brass, supplied and fixed, size 2" heavy quality. Stop cock brass supplied and fixed, size 1/2" heavy quality. Stop cock brass supplied and fixed, size 3/4" heavy quality. Brass stop cock supplying and fixing, size 1" ,heavy quality. Stop cock ,Brass,supplying and fixing, size 1 1/4" , heavy quality, Stop cock plastic (watertec) supplied and fixed, size 3/4" . Plastic water stop cock supplying and fixing, size 1" , Ball valve ,Brass, supplied and fixed, size 1/2" Ball valve supplying and fixing, size 3/4" . Ball valve ,Brass,supplying and fixing, size 1" , PVC Tee supplied and fixed size 1/2" PVC Tee supplied and fixed size 3/4" PVC Tee supplied and fixed size 1"

No No No No No No No No No No No No No No No No No No No No

60.40 80.00 139.30 750.80 2,193.20 2,505.90 2,846.20 5,644.40 366.60 632.00 769.30 375.90 282.60 324.20 859.50 1,242.00 1,169.10 59.80 70.70 87.50

Department of Engineering Services - Central Provincial Council

Concrete catch pits valve chambers in 50mm thick,concrete sides and internal sides cement rendered smooth, to be leak proof, with provision for necessary pipe connection/passage, with suitable cover or grating on top to be in flush with floor level, internal. Concrete catch pits, valve chambers in 50mm thick concrete sides and internal sides cement rendered smooth, to be leak proof, with provision fornecessary pipe connection/passage, with suitable cover or grating on top to be in flush with floor level, internal. Chain link mesh fence 2.1m high for 164m

No

332.50

No

332.50

No m2

430.60 2,190.74

No Sqft

430.60 203.60

BUILDING SCHEDULE OF RATES EFFECTIVE FROM - 2009 January Item No

Description Section 1 - BrickLayer/Mason

Unit

Rs

Rate Cts

B-001 B-002

Brick work in 1:5 cement sand mortar 225mm thick in foundations up to D.P.C. Brick work in 1:8 cement sand mortar 225mm thick in super structure ground floor

m3 m3 m3 m3 m3 m2 m2 m2 m2 m2 m3

8,340.00 8,110.00 8,515.00 8,680.00 8,920.00 1,040.00 1,095.00 1,115.00 1,145.00 575.00 4,120.00

B-002A Brick work in 1:8 cement sand mortar 225mm thick in super structure first floor B-002B Brick work in 1:8 cement sand mortar 225mm thick in second floor B-002C Brick work in 1:8 cement sand mortar 225mm thick in third floor B-003 Brick work in 1:5 cement sand mortar 112.5mm thick in ground floor

B-003A Brick work in 1:5 cement sand mortar 112.5mm thick in first floor B-003B Brick work in 1:5 cement sand mortar 112.5mm thick in second floor B-003C Brick work in 1:5 cement sand mortar 112.5mm thick in third floor B-004 B-005 B-006 Brick work in 1:5 cement sand mortar 112.5mm using available brick Brick work in 1:8 cement sand mortar 225mm thick or above ( using available bricks ) Masonry block work 100mm to 112.5mm thick in walls in cement sand 1:5 mortar using hollow blocks made of cement sand to the proportion 1:10, confirming to SLS standard.

m2

880.00

Page 1

Item No

Description

Unit

Rs

Rate Cts

Section 1 - BrickLayer/Mason B-006A Masonry block work 100mm to 112.5mm thick in walls in cement sand 1:5 mortar using hollow blocks made of cement sand to the proportion 1:10, confirming to SLS standard. in first floor B-006B Masonry block work 100mm to 112.5mm thick in walls in cement sand 1:5 mortar using hollow blocks made of cement sand to the proportion 1:10, confirming to SLS standard. in second floor B-006C Masonry block work 100mm to 112.5mm thick in walls in cement sand 1:5 mortar using hollow blocks made of cement sand to the proportion 1:10, confirming to SLS standard. in third floor B-007 Masonry block work 200mm thick in cement sand 1:5 mortar using hollow blocks made of cement sand to a proportion 1:10, confirming to SLS standard. in ground floor

m2

925.00

m2

945.00

m2

970.00

m2

1,455.00

B-007A Masonry block work 200mm thick in cement sand 1:5 mortar using hollow blocks made of cement sand to a proportion 1:10, confirming to SLS standard. in first floor m2 B-007B Masonry block work 200mm thick in cement sand 1:5 mortar using hollow blocks made of cement sand to a proportion 1:10, confirming to SLS standard. in second floor B-007C Masonry block work 200mm thick in cement sand 1:5 mortar using hollow blocks made of cement sand to a proportion 1:10, confirming to SLS standard. in third floor B-008 B-009 B-010 B-011 Supplying & fixing vent brick, size up to 390mm x 190mm x 100mm R.R masonry in 1:5 cement sand mortar in foundation using available rubble R.R masonry in 1:5 cement sand mortar in foundation m3 R.R masonry in 1:5 cement sand mortar in superstructure m3 7,880.00 7,330.00 1,525.00

m2

1,555.00

m2 No m3

1,595.00 150.00 5,525.00

Page 2

Item No B-012

Description Section 1of - BrickLayer/Mason Provision weep holes in retaining walls with 90mm dia PVC down pipes including metal packing around inner mouth as directed, length of pipe 600mm to 1050mm Provision of weep holes in retaining walls with 90mm dia PVC down pipes including metal packing around inner mouth as directed, length of pipe 1200mm to 1650mm Provision of weep holes in retaining walls with 90mm dia PVC down pipes including metal packing around inner mouth as directed, length of pipe 1800mm to 2250mm

Unit

Rs

Rate Cts

No

425.00

B-013

No

550.00

B-014

No

675.00

Page 3

Item No

Description Section 1 - BrickLayer/Mason Section 2 - Concrete Works

Unit

Rs

Rate Cts

C-001

Mixing and placing Concrete grade 30, Nominal mix 1:1 :2 (20mm).

m3 m3 m3 m3 m3 m3 m3 m3 m3 m3 m3 m3

16,160.00 16,645.00 16,970.00 17,290.00 13,330.00 13,730.00 13,995.00 14,265.00 12,170.00 12,535.00 12,780.00 13,020.00

C-001A Mixing and placing Concrete grade 30, Nominal mix 1:1 :2 ( 20mm) , in first floor. C-001B Mixing and placing Concrete grade 30, Nominal mix 1:1 :2 (20mm) , in second floor. C-001C Mixing and placing Concrete grade 30, Nominal mix 1:1 :2 ( 20mm) , in third fllor C-002 Mixing and placing Concrete grade 25, Nominal mix 1:1 1/2:3 ( 20mm).

C-002A Mixing and placing Concrete grade 25, Nominal mix 1:1 1/2:3 ( 20mm) ,in first floor. C-002B Mixing and placing Concrete grade 25, Nominal mix 1:1 1/2:3 ( 20mm) ,in second floor. C-002C Mixing and placing Concrete grade 25, Nominal mix 1:1 1/2:3 ( 20mm) ,in third floor. C-003 Mixing and placing Concrete grade 20, Nominal mix 1:2:4 ( 20mm).

C-003A Mixing and placing Concrete grade 20, Nominal mix 1:2:4 ( 20mm) ,in first floor. C-003B Mixing and placing Concrete grade 20, Nominal mix 1:2:4 ( 20mm) ,in second floor. C-003C Mixing and placing Concrete grade 20, Nominal mix 1:2:4 ( 20mm) ,in third floor. C-004 Mixing and placing Concrete 1:2 1/2:5 ( 25mm ) mixing and placing in position using a concrete mixer.

m3 C-005 Mixing and placing Concrete 1:3:6 (40mm) mixing and placing in position using a concrete mixer (including fuel/ operator/handling).

9,555.00

m3

9,245.00

Page 4

Item No C-006

Description Section - BrickLayer/Mason Tor steel1 reinforcement bend to shape laid in position and tied with G.I. wire as directed. Mild steel reinforcement bend to shape laid in position and tied with G.I. wire as directed. Sawn timber formwork in column in ground floor. Sawn timber form works for underside of floor slab. Sawn timber form work for concrete beams. Formwork in portal frames. Formwork in lintels and ground concrete works, plinth beams. Work tops, 50mm thick 1:2:4(20mm) complete with, reinforcement R6@100mm centre and shuttering. 2400mm x 600mm x 450mm plat form in brick or rubble sides and,2400mm x 300mm x 225mm step, 600mm thick 1:2 1/2:5 (25mm),Concrete topping, all inclusive of two risers,rendered smooth in 1:3 cement sand in red colour,and polished, providing 3 nos 50mm dia G.I. Flag ,posts, complete . Concrete cover slabs 50mm thick 1:2:4 (20 mm) r/f with, 6mm dia MS bars at bottom @ 100mm centre. both ways, finished smooth and neat sides, pre-cast in, pieces not exceeding 600mm x 450mm placed in position as directed, providing drain holes if required. Concrete catch pits, valve chambers in 50mm thick concrete sides and internal sides cement rendered smooth, to be leak proof, with provision for necessary pipe connection/passage, with suitable cover or grating on top to be in flush with floor level, internal. Drain 225mm X 150mm concrete 1:2 1/2:5 (25mm) 75mm thick expansion joints at 3000mm crs 12 mm thick , 1:3 cement sand rendering finish smooth, including neccessary excavation form work, laying polythene membrane and laid to required slope.

Unit Kg

Rs

Rate Cts

195.00

C-007

Kg m2 m2 m2 m2 m2 m2

190.00 835.00 805.00 960.00 965.00 625.00 1,655.00

C-008 C-009 C-010 C-011 C-012 C-013 C-014

No

30,585.00

C-015

m2

1,905.00

C-016

No

1,260.00

C-017

1,205.00

Page 5

Item No

Description Section 1 - BrickLayer/Mason Drain 225mm X 300mm concrete 1:2 1/2:5 (25mm) 75mm thick expansion joints at 3000mm crs 12.5mm thick , 1:3 cement sand rendering finish smooth, including neccessary excavation form work, laying polythene membrane and laid to required slope. Drain 225mm X 450mm concrete 1:2 1/2:5 (25mm) 75mm thick expansion joints at 3000mm crs 12.5mm thick , 1:3 cement sand rendering finish smooth, including neccessary excavation form work, laying polythene membrane and laid to required slope 750mm ramp and 225mm X 150mm Drain 1:2 1/2:5(25mm) concrete 75mm thick with 1:3 plaster finish smooth,including neccessary excavation,form work,providing expansion joints at 3000mm centers and laying polythene sheet. Readymixed concrete grade 20 pumping to any level rate including transport , pumping placing , porker vibrating,levelling and curing the concrete.rate for above 30m3

Unit

Rs

Rate Cts

C-018

1,650.00

C-019

1,890.00

C-020

2,150.00

C-021

m3

13,530.00

Page 6

Item No

Description Section 1 - BrickLayer/Mason Section 3 - Demolisher

Unit

Rs

Rate Cts

D-001 D-002 D-003 D-004 D-005 D-006

Ceiling asbestos removing including timber framework, stacking serviceable materials and debris cleared away. Ceiling, existing removed materials stacked and debris cleared in two storyed building. Doors, windows, partitions, weld mesh, shelves removed from existing walls and stacked. 225mm Drain cement and sand bricks, demolished and debris cleared. Floor paving brick, concrete or rubble inclusive of rendering and debris cleared away. Corrugated sheets, iron, asbestos or aluminium alloy removed from Roof including fame work inclusive of wiring and fixtures, gutters, valance boards etc.. in single story buildings.

m2 m2 m2 m m2

205.00 220.00 85.00 75.00 80.00

m2

70.00

D-006A Corrugated sheets, iron, asbestos or aluminium alloy removed from Roof including fame work inclusive of wiring and fixtures, gutters, valance boards etc.. in two storeyed buildings. D-006B Corrugated sheets, iron, asbestos or aluminium alloy removed from Roof including fame work inclusive of wiring and fixtures, gutters, valance boards etc.. in three storeyed buildings. D-007 Roof removing tile with fame work inclusive of wiring and fixtures, gutters, valance boards etc., stacking and clearing debris in in single storey buildings.

m2

75.00

m2

80.00

m2

110.00

D-007A Roof removing tiles with fame work inclusive of wiring and fixtures, gutters, valance boards etc.. ,stacking and clearing debris in two storeyed buildings. D-007B Roof removing tiles with fame work inclusive of wiring and fixtures, gutters, valance boards etc., stacking and clearing debris in three storeyed buildings and above.

m2

150.00

m2

190.00

Page 7

Item No

Description Section 1 - BrickLayer/Mason Tiles calicut or half round , removed from roof of single storey buildings including stacking and clearing debris.

Unit m2 m2

Rs

Rate Cts 40.00 60.00

D-008

D-008A Tiles calicut or half round , removed from roof of two storeyed buildings including stacking and clearing debris. D-008B Tiles calicut or half round , removed from roof of three storeyed buildings and above, including stacking and clearing debris. D-009 D-010 D-011 D-012 D-013 D-014 D-015 Truss steel or timber ( 6.1m ) 20 L.ft. Span. Truss steel or timber ( 7.6m )25 L.ft. Span. Truss steel or timber ( 9.1m )30 L.ft. Span. Walls bricks 112.5mm thick inclusive of plaster and any fixtures. Walls bricks above 225mm thick inclusive of plaster and any fixtures. Rubble masonry in cement, demolished, rubble stacked and debris removed inclusive of plaster and any fixtures. Reinforced concrete Walls, beams or slabs up to first floor.

m2 No No No m2 m3 m3 m3 m3 m3

80.00 1,520.00 1,900.00 2,280.00 160.00 655.00 815.00

5,360.00 5,500.00 5,905.00

D-015A Reinforced concrete Walls, beams or slabs up to second floor. D-015B Reinforced concrete Walls, beams or slabs up to 3 rd floor. D-016 Door or window size up to 4.0m 2 removed from existing walls and stacked. Door or window size over 4.0m 2 removed from existing walls and stacked. Door or window sash only size up to 4.0m 2 removed from existing walls and stacked.

No

720.00

D-017

No m2

1,080.00

D-018

100.00

Page 8

Item No

Description Section 1 - BrickLayer/Mason Door or window sash only size over 4.0m 2 removed from existing walls and stacked. Gutters, down pipes, valley GI or PVC including fixtures removed cleaned and stacked.. Boards, valance and barge removed cleaned and stacked.

Unit

Rs

Rate Cts

D-019

m2 m m

145.00 20.00 15.00 295.00 185.00 30.00 10.00 90.00 135.00 115.00 160.00

D-020 D-021 D-022 D-023 D-024 D-025 D-026 D-027 D-028 D-029

Low-level suits, squatting pans removed and stacked. wash basins, cisterns, sinks, urinals removed and stacked. Ridges, asbestos or tile, removed cleaned and stacked. Pipes PVC, GI, removed cleaned and stacked. Rendering, cement, chipped and debris cleared away from brick walls and floors. Rendering, cement, chipped and debris cleared away from cement concrete floors and walls. Fence uprooted, barbed wire 5 strands rolled up and all materials stacked (Length of fencing to be measured). Tiled, glazed demolished and debris cleared.

No No m m m2 m2 m m2

Page 9

Item No

Description Section 1 - BrickLayer/Mason Section 4 - Excavator

Unit

Rs

Rate Cts

E-001 E-002 E-003 E-004

De-watering during construction in work under water table, for plaster work. Earth excavation in levelling site inclusive of haulage up to 100 m. (manual cutting only up to 450m 3) Earth excavation in levelling site inclusive of haulage up to 100 m. (machine cutting only) in ordinary soil Excavation in foundations in normal earth up to depth of 1.5m inclusive of backfilling, compacting and disposal of surplus earth. Excavation in foundations in soft rock requiring manual digging, up to a depth of 1.5m inclusive of backfilling and disposal of surplus materials. Excavation in levelling site in hard rock involving blasting inclusive of haulage up to 100 m., and piling rubble, extra over earth excavation payable on rubble measurement only. Excavation in levelling site in soft rock involving manual digging inclusive of haulage up to 100 m. Excavation in wells / pits in normal earth up to depth of 1.5m inclusive of backfilling behind wall/ ring and disposal of surplus earth, rate excluding for shoring. Excavation in wells / pits in normal earth 1.5m to 3.0m depth inclusive of backfilling behind wall/ring and disposal of surplus earth, rate excluding for shoring. Excavation in wells / pits in normal earth 3.0m to 4.5m depth inclusive of backfilling behind wall/ring and disposal of surplus earth, rate excluding for shoring.

m2 m3 m3

95.00 400.00 110.00

m3

590.00

E-005

m3

790.00

E-006

m3

1,015.00

E-007 E-008

m3

780.00

m3

655.00

E-009

m3

905.00

E-010

m3

1,290.00

Page 10

Item No E-011

Description Section 1 - in BrickLayer/Mason E xcavation wells / pits in normal earth 4.5m to 6.0m depth inclusive of backfilling behind wall/ring and disposal of surplus earth, rate excluding for shoring. Filling earth and compacting (as approved by Engineer) 150mm layers in large quantities, rate includes for transport 100 m. Filling earth and compacting (as approved by Engineer) 150mm layers under floors, rate includes for transport 100 m. Shoring for excavations for 3m height Wells bailed out and cleaned total depth up to 3.0m(measured, capacity of well below water table) Wells bailed out and cleaned total depth up to 4.8m(measured, capacity of well below water table) Wells bailed out and cleaned total depth up to 7.5m(measured, capacity of well below water table) Extra over excavation for removing boulders size exceeding 0.05m3.,in any manner (volume of each boulder measured as 0.75xaverage breadth squared x length)

Unit

Rs

Rate Cts

m3

1,680.00

E-012

m3

460.00

E-013

m3 m2 m3 m3 m3

535.00 355.00

E-014 E-015 E-016 E-017 E-018

200.00 395.00 555.00

m3 E-019 E-020 E-021 E-022 Haulage of earth more than 100 m away from site deposited and spread by any means. Levelling ground to required grading cutting lumps and spreading and compacting manually. Disposal of surplus earth, inclusive of loading and unloading and transport up to 5 km Compacting approved Gravel, filled in 150mm layers by manual tamping as specified. (gravel available at site) m3 m2 m3 m3

1,270.00 160.00 15.00 225.00 385.00

Page 11

Item No

Description Section 1 - BrickLayer/Mason River sand supplied and spread in layers as specified under foundations, drainage sand blankets, filters, around soakage pits, wells etc. Compacting approved Gravel in 150mm layers by any means except manual tampering as specified. ( gravel available at site) Rock excavation in column footing or wall foundation.

Unit

Rs

Rate Cts

E-023

m3

1,785.00

E-024

m3 m3

160.00

E-025 E-026

2,320.00 1,760.00

Quarry dust filling under foundation (as a cushion )

m3

Page 12

Item No

Description Section 1 - BrickLayer/Mason Section 5 - Flooring/Paving

Unit

Rs

Rate Cts

F-001

Floor - brick 62mm thick, 1:3 cement rendered and smooth with cement grout expansion joints filled in 1:2 bitumen sand. ( rate including for curing) Extra over to cement finish for adding colour cement powder .( rate including for curing) Floor - brick 62mm thick, 1:3 cement rendered with expansion joints filled in 1:2 bitumen sand rate including for curing , bricks available. Floor concrete 1:2 1/2:5(25mm) 62mm thick 1:3 cement rendered with expansion joints filled in 1:2 bitumen sand, rate including for curing, compacting ground and laying polythene sheet under the concrete. Floor concrete 1:2 1/2:5(25mm) 62mm thick with expansion joints filled in 1:2 bitumen sand rate including for curing, compacting ground and laying polythene sheet under the concrete. Floor paved with approved cement pressed tiles on 1:3 cement mortar joints filled with cement grout of matching colour and clearing. (concrete base measured separately)

m2 m2

1,300.00 55.00

F-002 F-003

m2

1,105.00

F-004

m2

1,120.00

F-005

m2

695.00

F-006

m2 F-007 Floor paved with approved pattern and colour ceramic floor tiles on 1:3 cement mortar, joints filled with cement grout of matching colour and clearing. (concrete base measured separately) Floor re- rendered 1:3 cement sand after demolition and clearance of the damaged areas, providing expansion joints filled in 1:2 bitumen sand (rate including for curing) m2 F-009 Floor rendered 1:3 cement sand normal cemented surface with expansion jointsfilled in 1:2 bitumen sand. ( rate including for curing)

1,915.00

m2

2,765.00

F-008

510.00

m2

430.00

Page 13

Item No

Description Section 1 - BrickLayer/Mason Floor rendered 1:3 cement sand approved coloured surface with expansion joints filled in 1:2 bitumen sand. ( rate including for curing) Extra over, for coloured cement floor waxed and polishing. Tiles glazed of approved pattern and colour with all specials supplied and fixed to walls including raking plaster and bedding in cement mortar 1:3.Joints finished with cement grout of matching colour and clearing. Waterproofing in upper floor bathrooms, water tanks etc. with, cementitious water proofing agent, (barralastic or equivalent )apply two coats after well cleared surface. (as Engineer's instruction )

Unit

Rs

Rate Cts

F-010

m2 m2

460.00 210.00

F-011 F-012

m2

2,690.00

F-013

m2

1,165.00

Page 14

Item No

Description Section 1 - BrickLayer/Mason Section 6 - General/Misce

Unit

Rs

Rate Cts

G-001 G-002 G-003 G-004 G-005 G-006 G-007 G-008 G-009 G-010

Clearing jungle along the fence Cutting coconut trees removing root ball and stacking logs. Cutting coconut trees removing stumps to ground Cutting trees girth 0.45m to 0.9m, removing rootball and stacking logs. Cutting trees girth 0.45m to 0.9m,stacking logs. Cutting trees girth 0.925m to 1.35m, removing rootball and stacking logs. Cutting trees girth 0.925m to 1.35m,stacking logs. Cutting trees girth 1.375m to 1.8m, removing rootball and stacking logs. Cutting trees girth 1.375m to 1.8m,stacking logs. Cutting trees girth 1.825m to 2.25m, removing rootball and stacking logs. Cutting trees girth 1.8m to 2.25m,stacking logs. Cutting trees girth 2.2m to 2.7m, removing rootball and stacking logs. Cutting trees girth 2.2m to 2.7m,stacking logs. Fence wire barbed 2.03mm dia.,with 4 points, available. strengthened and fixed on existing concrete or timber posts. Fence wire barbed 2.03mm dia., with 4 points, supplied and fixed on existing concrete or timber posts.

m No No No No No No No No

25.00 2,645.00 1,890.00 4,080.00 2,595.00 5,935.00 4,450.00 8,530.00 7,045.00

No No No No

11,865.00 10,380.00 14,460.00 12,980.00

G-011 G-012 G-013 G-014

m m

15.00 25.00

G-015

Page 15

Item No

Description Section 1 - BrickLayer/Mason Flight of steps in 1:2 1/2 :5(25mm) concrete overallwidth 1.5m, waist 100mm on well compacted ground,waist below ground level, curb walls 150mm thick overall height 450mm in outer surface, rate includes all formwork and rendering exposed surfaces 1:3 , size of step150mm rise and 275mm tread. Landing in flight of steps 1.5m wide overall base 100mm thick, curb walls 150mm thick and 150mm height externally, in1:2 1/2:5(25mm) concrete, cement rendered 1:3.cement sand finished rough Supply and laying 1.5mX 1.0m X 1.0m glavanized Gabion boxes with necessary rubble and metal. Supply and laying 2.0mX 1.0m X 1.0m glavanized Gabion boxes with necessary rubble and metal. Supply and laying 1.0mX 1.0m X 1.0m glavanized Gabion boxes with necessary rubble and metal. Fence barbed wire 5 strands 14 BWG with 4 points at 75mm crs and R.C.C posts 1:2:4 (20mm) 1.70m high, R/F with 4 nos 6mm rods , cement concrete foundations 1:3:6(40mm)to corner posts and struts and straightening bolts all. Fence barbed wire 8 strands 14 BWG with 4 points at 75mm crs and R.C.C posts 2.25m high fixed at 2.4mcrs, cement concrete foundations 1:3:6(40mm) to corner posts and struts and straightening bolts all as per type plan, the struts to be r/f with 4 nos. Fence posts intermediate, or struts, cement concrete 1:1 1/2:3(3/4") r/f with 4 nos 6mm ms rods ,1.7m high and section 150mm x 150mm bottom and 100mm x 100mm top, as per drawing. Fence posts intermediate, or struts, cement concrete 1:1 1/2:3(20mm) r/f with 4 nos 6mm ms rods .2.25m high and section 150mm x 150mm bottom and 100mm x 100mm top, as per drawing

Unit

Rs

Rate Cts

G-016

7,350.00

G-017

m No No No

6,185.00 10,935.00 14,060.00 8,000.00

G-018 G-019 G-020 G-021

660.00

G-022

700.00

G-023

No

1,060.00

G-024

No

1,115.00

Page 16

Item No

Description Section 1 - BrickLayer/Mason Fence posts RC ,available, re fixed rate to include for concreting where necessary. Supplying and laying Geo textile layer behind the gabion retaining wall type T.S. 30 Cutting turf sods, loading to hand carts and transporting up to 30 yards, laying and watering for 30days. (Royalty for turf, pegging and transport beyond 30 yards paid separately)

Unit

Rs

Rate Cts

G-025 G-026

No m2

95.00

120.00

G-027

m2

115.00

Page 17

Item No

Description Section 1 - BrickLayer/Mason Section 7 - Health & Sewer

Unit

Rs

Rate Cts

H-001 H-002 H-003

Elbow pvc 110mm supplied and fixed Bend PVC 110 supplied and fixed ,Drainage Type 400 pvc 110mm for sewer line Supplied and laid in medium soil, joints embedded in 1:3:6 ( 40mm ) concrete including necessary excavation, back filling, and compaction invert depth to 600mm to 900mm Type 400 pvc 110mm for sewer line Supplied and laid in medium soil, joints embedded in 1:3:6 ( 40mm ) concrete including necessary excavation, back filling, and compaction, invert depth up to 600mm Type 400 pvc 160mm for sewer line Supplied and laid in medium soil, joints embedded in 1:3:6 (40mm ) concrete including necessary excavation, back filling, and compaction invert depth to 600mm to 900mm Type 400 pvc 160mm for sewer line Supplied and laid in medium soil, joints embedded in 1:3:6 ( 40mm ) concrete including necessary excavation, back filling, and compaction, invert depth up to 600mm Gully PVC 150mm supplied and fixed including concreting and supplying necessary grating. Manhole 600mm x 600mm x 600mm internally complete with ct concrete 1:2:4 in 75mm thick base, on top of brick walls channelling and bending, walls 225mm brick, 1:3 cement rendered 75mm thick RC. cover r/f 10mm tor @ 150mmcc. both ways, complete with lifting handles.

No No

985.00 665.00

775.00

H-004

720.00

H-005

2,260.00

H-006

2,160.00

H-007

No

460.00

H-008

No

8,970.00

Page 18

Item No

Description

Unit

Rs

Rate Cts

Section 1 - BrickLayer/Mason H-008A Manhole 600mm x 600mm internally complete with ct concrete 1:2:4 in 75mm thick base, cooping on top opf brick walls channelling and bending, RCC 1:2:4 in 50mm thick cover slab R/f,walls 225mm brick, 1:3 cement rendered,extra over for each additional 0.3 m depth H-009 Manhole 1.05m x 0.675m x 0.60m internally with ct concrete 1:2:4 in 75mm thick base ,channelling, walls 255mm brick, 1:3 cement rendered 75mm thick RC. cover r/f 10mm tor @ 150mmcc. both ways, complete with lifting handles. Manhole 1.05m x 0.675m internally with concrete base, channeling, walls 225mm brick, 1:3 cement rendered 75mm thick RC. cover r/f 10mm tor Steel at 150mmcc. both ways, complete with lifting handles.extra over each additional 0.3 m depth Shallow drains in floors 75mm diameter in cement concrete 1:2:4, 75mm thick in bottom and sides including cement rendering Soakage pit 1.2m diameter internal fully built type invert depth level of 0.9m, raised 150mm above ground level complete with RC cover as per type plan.CP/K/119/91A Soakage pit 1.2m diameter internal semi built type, built up from invert depth level of 0.9m raised 150mm above ground level complete with RC cover as per type plan.CP/K/119/91A T, pvc 110mm supplied and fixed drainage Soakage pit 1.8m diameter internal fully built type invert depth level of 0.9m, raised 150mm above ground level complete with RC cover as per type plan CP/K/253/92A Vent pvc 110mm diameter (type 400) fixed on walls with timber plugs and pvc brackets. (Specials paid separately)

No

2,420.00

No

13,700.00

H-010

No

3,200.00

H-011

840.00

H-012

No

59,480.00

H-013

No No

30,365.00 740.00

H-014 H-015

No

75,645.00

H-016

740.00

Page 19

Item No

Description

Unit

Rs

Rate Cts

Section 1 - BrickLayer/Mason H-016A Construction of septic tanks for 15 persons 2.1m X 0.75m internally As per detail drawing No. CP/K/117/91A H-017 Construction of septic tanks for 25 persons 2.4m X 0.75m internally As per detail drawing No. CP/K/117/91A Septic tank for 25 persons as per type plan complete, extra over for invert depth exceeding.600mm to 1800mm, per each additional 0.3 m. Septic tank for 50 persons invert depth up to 0.75m complete as per Type plan No:CP/K/121/91A. Septic tank for 50 persons as per type plan complete, extra over for invert depth exceeding 600mm to 1800mm, per each additional 0.3 m. Septic tank for 100 persons invert depth up to 2250mm complete as per Type plan No:CP/K/121/91A. Septic tank for 100 persons as per type plan complete, extra over for invert depth exceeding 600mm to 1800mm, per each additional 0.3 m.

No

63,660.00

No

69,040.00

H-018

No No

6,350.00 91,915.00

H-019 H-020

No

7,380.00

H-021

No

132,210.00

H-022

No

10,370.00

Page 20

Item No

Description Section 1 - BrickLayer/Mason Section 8 - Electrical

Unit

Rs

Rate Cts

I-001

Lamp point wiring - to be carried out with 2 x 1.00 mm 2 pvc insulated pvc sheathed copper cables terminated in a terminal ceiling rose and sunk switch wired in consealed conduit in wall and above ceiling to be supplyed and installed in working order. Water tight lamp point wiring - to be carried out with 2 x 1.00 mm2 pvc insulated pvc sheathed copper cables terminated in a terminal ceiling rose and sunk switch wired in consealed conduit in wall and above ceiling to be supplyed and installed in working order. Indoor bracket lamp point wiring - to be carried out with 2 x 1.00 mm2 pvc insulated pvc sheathed copper cables terminated in a terminal ceiling rose and sunk switch wired in consealed conduit in wall and above ceiling to be supplyed and installed in working order. Stairway lamp point wiring - to be carried out with 2 x 1.00 mm2 pvc insulated pvc sheathed copper cables terminated in a terminal ceiling rose and sunk switch wired in consealed conduit in wall and above ceiling to be supplied and installed in working order. Ceiling fan point wiring complete with fan hook - to be carried out with 2 x 1.00 mm2 pvc insulated pvc sheathed copper cables and 2.5mm2 earth cable terminated in a terminal ceiling rose and sunk switch wired in consealed conduit in wall and above ceiling to be supplyed and installed in working order. 5 A.M.P. socket outlets - to be carried out with 2 x 1.00 mm2 pvc insulated pvc sheathed copper cables and 2.5mm2 earth cable terminated in a terminal wired in consealed conduit in wall and above ceiling to be supplyed and installed in working order.

No

1,035.00

I-002

No

955.00

I-003

No

1,130.00

I-004

No

2,020.00

I-005

No

1,320.00

I-006

No

1,165.00

Page 21

Item No

Description Section 1 - BrickLayer/Mason 13 .A.M.P. socket outlets - to be carried out with 2 x 2.50 mm2 pvc insulated pvc sheathed copper cables and 2.5mm2 earth cable terminated in a terminal wired in consealed conduit in wall and above ceiling to be supplyed and installed in working order. 15 A.M.P Socket out let - to be carried out with 2 x 2.50 mm2 pvc insulated pvc sheathed copper cables and 2.5mm2 earth cable terminated in a terminal wired in consealed conduit in wall and above ceiling to be supplyed and installed in working order. 15 A.M.P. switch socket outlet c/w 20A D.P. switch with neon indicator lamp - to be carried out with 2 x 2.50 mm2 pvc insulated pvc sheathed copper cables and 2.5mm2 earth cable terminated in a terminal wired in consealed conduit in wall and above ceiling to be supplyed and installed in working order. Lamp point wiring - to be carried out with 2 x 1.00 mm2 pvc insulated pvc sheathed copper cables terminated in a terminal ceiling rose and sunk switch wired with pvc casing on wall and on soffit of the slabs to be supplyed and installed in working order. Water tight lamp with point wiring - to be carried out with 2 x 1.00 mm2 pvc insulated pvc sheathed copper cables terminated in a terminal ceiling rose and sunk switch wired with pvc casing on wall and on soffit of the slabs to be supplyed and installed in working order. Indoor bracket lamp point - to be carried out with 2 x 1.00 mm2 pvc insulated pvc sheathed copper cables terminated in a terminal ceiling rose and sunk switch wired with pvc casing on wall and on soffit of the slabs to be supplyed and installed in working order.

Unit

Rs

Rate Cts

I-007

No

1,530.00

I-008

No

1,650.00

I-009

No

2,595.00

I-010

No

935.00

I-011

No

935.00

I-012

No

995.00

Page 22

Item No

Description Section 1 - BrickLayer/Mason Stairway lamp point - to be carried out with 2 x 1.00 mm2 pvc insulated pvc sheathed copper cables terminated in a terminal ceiling rose and sunk switch wired with pvc casing on wall and on soffit of the slabs to be supplyed and installed in working order. Ceiling fan point wiring complete with fan hook - to be carried out with 2 x 1.00 mm2 pvc insulated pvc sheathed copper cables and 2.5mm2 earth cable terminated in a terminal ceiling rose and sunk switch wired with pvc casing on wall and on soffit of the slabs to be supplyed and installed in working order. 5 AMP socket out let - to be carried out with 2 x 1.00 mm2 pvc insulated pvc sheathed copper cables and 2.5mm2 earth cable terminated in a terminal wired with pvc casing on wall and on soffit of the slabs to be supplyed and installed in working order. 13 AMP socket out let - to be carried out with 2 x 2.50 mm2 pvc insulated pvc sheathed copper cables and 2.5mm2 earth cable terminated in a terminal wired with pvc casing on wall and on soffit of the slabs to be supplyed and installed in working order. 15 AMP socket outlet - to be carried out with 2 x 2.50 mm2 pvc insulated pvc sheathed copper cables and 2.5mm2 earth cable terminated in a terminal wired with pvc casing on wall and on soffit of the slabs to be supplyed and installed in working order.

Unit

Rs

Rate Cts

I-013

No

1,850.00

I-014

No

1,590.00

I-015

No

1,155.00

I-016

No

1,425.00

I-017

No I-018 I-019 2 Way SP x N Distribution Board complte with 30 AMP 2P M.C.B. and R.C.C.B. 4 Way SP x N Distribution Board complte with 30 AMP 2P M.C.B. and R.C.C.B. 6 Way SP x N Distribution Board complte with 30 AMP 2P M.C.B. and R.C.C.B. No

1,535.00 7,440.00

No

8,850.00

I-020

No

10,380.00

Page 23

Item No

Description Section 1 - BrickLayer/Mason 8 Way SP x N Distribution Board complte with 30 AMP 2P M.C.B. and R.C.C.B. 10 Way SP x N Distribution Board complte with AMP 2P M.C.B. and R.C.C.B. 12 Way SP x N Distribution Board complte with AMP 2P M.C.B. and R.C.C.B. 2 Way SP x N Distribution Board complte with 60 AMP 2P M.C.B. and R.C.C.B. 4 Way SP x N Distribution Board complte with 60 AMP 2P M.C.B. and R.C.C.B. 6 Way SP x N Distribution Board complte with 60 AMP 2P M.C.B. and R.C.C.B. 8 Way SP x N Distribution Board complte with 60 AMP 2P M.C.B. and R.C.C.B. 10 Way SP x N Distribution Board complte with 60 AMP 2P M.C.B. and R.C.C.B. 12 Way SP x N Distribution Board complte with 60 AMP 2P M.C.B. and R.C.C.B. Supplying and Installation of 2 way TPxN Distribution Board complte with 60 A, 4P, M.C.B. and 2 Nos 32A, 3P, M.C.B. in surface mount plastic enclosure Supplying and Installation of 4 way TPxN Distribution Board complte with 60 A, 4P, M.C.B. and 4 Nos 32A, 3P, M.C.B. in surface mount metal enclosure Supplying and Installation of 2 way TPxN Distribution Board complte with 100 A, 4P, M.C.C.B. and 2 Nos 30/60A, 3P, M.C.B. in surface mount metal enclosure Supplying and Installation of 4 way TPxN Distribution Board complte with 125 A, 4P, M.C.C.B. and 4 Nos 30/60A, 3P, M.C.B. in surface mount metal enclosure 30

Unit

Rs

Rate Cts

I-021

No

11,400.00

I-022

No 30 No

12,900.00

I-023

14,880.00

I-024

No

8,820.00

I-025

No No No No No

12,810.00 14,040.00 15,060.00 16,560.00 18,540.00

I-026 I-027 I-028 I-029 I-030

No

7,925.00

I-031

No

21,395.00

I-032

No

47,685.00

I-033

No

79,890.00

Page 24

Item No

Description Section 1 - BrickLayer/Mason Supplying and Installation of 20-100 A, 4P, M.C.C.B. In a surface mount metal enclosure Supplying and Installation of 30 AMP, 2P, Isolator complete with plastic enclosure Supplying and Installation of 60 AMP, 2P, Isolator complete with plastic enclosure Supplying and Installation of 30 AMP, 4P, Isolator complete with plastic enclosure Supplying and Installation of 60 AMP, 4P, Isolator complete with plastic enclosure Supplying and Installation of 40 A,30mA, 2P, R.C.C.B. in a Surface mount Plastic enclosure . Supplying and Installation of 60 A,30mA, 2P, R.C.C.B. in a Surface mount Plastic enclosure Supplying and Installation of 40 A,30mA, 4P, R.C.C.B. In surface mount Plastic enclosure Supplying and Installation of 60 A,30mA, 4P, R.C.C.B. In Surface mount Plastic enclosure Supply and installation of 2 x 1 mm 2 + 2.5 mm2 earth cable in conduit Supply and installation of 2 x 2.5 mm 2 + 2.5 mm2 earth cable in conduit Supply and installation of 2 x 4.0 mm 2 + 2.50 mm2 earth cable in conduit Supply and installation of 2 x 6.0 mm 2 + 6.0 mm2 earth cable in conduit Supply and installation of 2 x 10.0 mm 2 + 10.0 mm2 earth cable in conduit

Unit

Rs

Rate Cts

I-034 I-035 I-036 I-037

No No No

18,390.00 2,975.00 3,290.00

No No No No No No

4,490.00 5,150.00 5,090.00 5,090.00 7,790.00 9,890.00

I-038 I-039 I-040 I-041 I-042 I-043

305.00

I-044

m m

400.00 555.00

I-045 I-046

790.00

I-047

1,160.00

Page 25

Item No

Description Section 1 - BrickLayer/Mason Supply and installation of 2 x 16.0 mm 2 + 16.0 mm2 earth cable in conduit Supply and installation of 2 x 25.0 mm 2 + 16.0 mm2 earth cable in conduit Supply and installation of 4 x 25.0 mm 2 + 25.0 mm2 earth cable in conduit Supply and installation of 4 x 4.0 mm 2 + 4.0 mm2 earth cable in conduit Supply and installation of 4 x 6.0 mm 2 + 6.0 mm2 earth cable in conduit Supply and installation of 4 x 10.0 mm 2 + 10.0 mm2 earth cable in conduit Supply and installation of 4 x 16.0 mm 2 + 16.0 mm2 earth cable in conduit Supply and installation of 4 x 25.0 mm 2 + 16.0 mm2 earth cable in conduit Supply and installation of 4 x 35.0 mm 2 + 16.0 mm2 earth cable in conduit Supply and installation of 2 x 1.5 mm 2 + 2.50 mm2 earth cable in casing Supply and installation of 2 x 2.5 mm 2 + 2.5 mm2 earth cable in casing Supply and installation of 2 x 4 mm 2 + 2.50 mm2 earth cable in casing Supply and installation of 2 x 6 mm 2 + 6 mm2 earth cable in casing Supply and installation of 2 X 10 mm2 + 10 mm2 earth cable in casing

Unit

Rs

Rate Cts

I-048

1,675.00

I-049

2,400.00

I-050

3,695.00

I-051

1,025.00

I-052

1,280.00

I-053

1,850.00

I-054

2,525.00

I-055

3,965.00

I-056

4,780.00

I-057

280.00

I-058

380.00

I-059

535.00

I-060

700.00

I-061

1,070.00

Page 26

Item No

Description Section 1 - BrickLayer/Mason Supply and installation of 2 X 16 mm2 + 16 mm2 earth cable in casing Supply and installation of 2 X 25 mm2 + 16 mm2 earth cable in casing Supply and installation of 4 X 25 mm2 + 25 mm2 earth cable in casing Supply and installation of 4 X 4 mm2 + 4 mm2 earth cable in casing Supply and installation of 4 X 6 mm2 + 6 mm2 earth cable in casing Supply and installation of 4 X 10 mm2 + 10 mm2 earth cable in casing Supply and installation of 4 X 16 mm2 + 16 mm2 earth cable in casing Supply and installation of 4 X 25 mm2 + 16 mm2 earth cable in casing Supply and installation of 4 X 35 mm2 + 16 mm2 earth cable in casing Pendent lamp c/w 200mm dia. conical plastic shade and 60W incandescent bulb Pendent lamp c/w 200mm dia. glass globe and 60W incandescent bulb Water tight bracket lamp c/w 200mm dia. clear acrylic globe and 15W C.F.L. bulb, 4 star rating Indoor bracket lamp c/w 200mm dia. opal white glass globe and 40W incandescent bulb Recessed fluorescent lamp fitting 1200mm x 600mm, complete with polished aluminium double parabolic louver and 2 Nos 36 W,1200mm fluorescent bulbs

Unit

Rs

Rate Cts

I-062

m m m m m m m m m No No No

1,505.00 2,290.00 3,675.00 1,005.00 1,190.00 1,740.00 2,415.00 3,850.00 4,660.00 305.00 1,315.00 1,455.00

I-063 I-064 I-065 I-066 I-067 I-068 I-069 I-070 I-071 I-072 I-073 I-074

No

1,130.00

I-075

No

6,810.00

Page 27

Item No

Description Section 1 - BrickLayer/Mason Fluorescent lamp fittings 1200mm single batten type with 1Nos 36 W,1200mm fluorescent bulb Fluorescent lamp fittings 1200mm single totally encased suspension type with 1No 36 W,1200mm fluorescent bulb Fluorescent lamp fittings 600mm single totally encased suspension type with 1No 18 W,1200mm fluorescent bulb Fluorescent lamp fittings 1200mm single suspension type, complete with prismatic diffuser and 1No 36W 1200mm fluorescent bulb Fluorescent lamp fittings 600mm single,suspension type complete with prismatic diffuser and 1 1No 18W 600mm fluorescent bulb Fluorescent lamp fittings 1200mm twin, complete with prismatic diffuser and 2 No 36W 1200mm fluorescent bulb Fluorescent lamp fittings 1200mm single, industrial type c/w 1 x 36W bulb suspension type Fluorescent lamp fittings 1200mm twin, industrial type c/w 2 x 36W bulb suspension type Fluorescent lamp fittings 600mm single, industrial type c/w 18W bulb suspension type Rescesed down light complete with 250 D.A. polish aluminium. Reflector and 20W C.F.L. bulb , 4 strar rating Bulk head lamp water tight c/w 18 W CFL bulb 4 star rating Supplying and installation of Door Bell (excluding wiring) Supplying and Installation of ceiling fan 1400mm dia. complete with 5 speed regulator (Excluding wiring)

Unit

Rs

Rate Cts

I-076

No

1,235.00

I-077

No

1,655.00

I-078

No

1,535.00

I-079

No

1,655.00

I-080

No

1,535.00

I-081

No

2,410.00

I-082

No No No

1,715.00 2,590.00 1,655.00

I-083 I-084 I-085

No No No

1,670.00 1,175.00 765.00

I-086 I-087 I-088

No

7,465.00

Page 28

Item No

Description Section 1 - BrickLayer/Mason Supplying and Installation of 200mm dia. Exhaust fan with Auto shutter (Excluding wiring) Supplying and Installation of 250mm dia. Wall fan with speed regulator to working order (Excluding wiring) Supplying and Installation of Earth electrode 20mm dia. 5 feet long to working order complte with forming of gully around the pipe Supplying and Installation of 5 AMP socket outlet Supplying and Installation of 13 AMP socket outlet Supplying and Installation of 15 AMP socket outlet

Unit

Rs

Rate Cts

I-089

No

6,265.00

I-090

No

10,960.00

I-091

No No No No

1,620.00 415.00 435.00 490.00

I-092 I-093 I-094

Page 29

Item No

Description Section 1 - BrickLayer/Mason Section 9 - Joiner

Unit

Rs

Rate Cts

J-001 J-002 J-003 J-004 J-005 J-006 J-007

Barrel bolts 100mm brass supplied & fixed with brass screws. Barrel bolts 100mm ox. iron supplied & fixed with iron screws. Barrel bolts 150mm brass supplied & fixed with brass screws. Barrel bolts 150mm ox. iron supplied & fixed with iron screws. Butt hinges brass 100mm x 62mm supplied and fixed with brass screws. Butt hinges oxidized iron 100mm x 62mm supplied and fixed with iron screws. Cabin hook iron 100mm to 150mm supplied & fixed with iron screws. Casement stays 300mm Iron oxidized supplied and fixed with iron screws. Collapsible door, iron, open type complete with locking arrengment and two coats anticorrosive paint and two coats of enamal paint. Door 28mm thick, battened sash with 95mm x 45mm frame, incl.1 timber, oxidized heavy duty furniture 100mm x 62mm iron butt hingers within side and out side 100mm barrel bolts and painted sashes two coats cream enamel paint &frame two coats brown enamel paint including primer under coats, Door 28mm thick battened, sash single hung with 95mm x 45mm frame with, in Jack timber, oxidized heavy duty furniture with 100mm barrel bolt rate to included primer under coats and two coats of enamel paint.

No No No No Pr Pr

275.00 210.00 365.00 240.00 720.00 405.00

No No

35.00 305.00

J-008b J-009

m2

6,960.00

J-010

m2

7,050.00

J-011

m2

10,290.00

Page 30

Item No

Description Section 1 - BrickLayer/Mason Door 28mm thick flush paneled sash single hung with 95mm x 70mm frame,in cl.1 timber, oxidized heavy duty furniture, Union or Yale original mortice lock, rate to incuded two coats enamel paint . Door 28mm thick flush paneled sash single hung with 95mm x 70mm frame,in Jack timber, oxidized heavy duty furniture, Union or Yale original mortice lock, rate to included two coats of enamel paint all complete . Door 28mm thick paneled & glassed double hungsashes and top fanlight 95mm x 70mm frame,cl.1timber,oxidized heavy duty furniture, Union orYale original mortice lock, rate included to two coats of enamel paint. Door 28mm thick paneled & glassed double hungsashes and top fanlight 95mm x 70mm frame,in Jack/special timber,oxidized heavy duty furniture,Union orYale original mortice lock,rate included to two coats of enamel paint. Door 28mm thick flush paneled, sash with 95mm x 45mm frame, in cl.1 timber, oxidized heavy duty furniture with inside and out side 100mm bolts in lieu of lock and rate included to two coats enamel paint, Door 28mm thick flush paneled, with 95mm x 45mm frame, inJ ack/special timber, oxidized heavy duty furniture withinside and out side 100mm bolts in lieu of lock and rate included two coats of enamel paint, Door 28mm thick plywood sash with 95mm x 70mm Cl.1timber frame, oxidized heavy duty furniture, Unionor Yale original mortice lock, rate to included two coats of enamel paint. Door 28mm thick plywood sash with 95mm x 70mm special timber frame, oxidized heavy duty furniture, Union or Yale original mortice lock, rate to includede two coats of enamel paint. Door and window frames repaired and re-fixed ,Timber if used measured separately

Unit

Rs

Rate Cts

J-012

m2

11,520.00

J-013

m2

14,400.00

J-014

m2

11,290.00

J-015

m2

13,035.00

J-016

m2

8,985.00

J-017

m2

11,950.00

J-018

m2

9,235.00

J-019

m2

9,350.00

J-020

No

180.00

Page 31

Item No

Description Section 1 - BrickLayer/Mason Door or window sash repaired and re- fixed(timber, except beadings if used measuredseparately) Draw rings 40mm supplied and fixed Glass panes replacing 3mm clear rate includes for necessary beadings etc. Glass panes replacing 3mm pinhead ,rate includes for necessary beadings etc. Hasp & staple 100mm to 15mm supplied and fixed with 50mm heavy duty Union or equivalent padlock Lock rim or night latch (Chinese) supplied & fixed Lock Union or equivalent mortice, supplied & fixed Lock Union or equivalent mortice, supplied & fixed to double hung doors Security weld mesh door sash with lock, in GI weld mesh 50mm x 50mm SWG 10, welded on 40x40x5 mm MSangle frame complete with application of twocoats brown enamel paint over two coats of anticorrosive paint complete . Security weld mesh in open type buildings in GI weld mesh 50mm x 50mm SWG 10, welded on 40x40x5 mm angle frame complete with application of twocoats brown enamel paint over two coats of anticorrosive paint complete . Special security grille fixed to aluminium windows complete .(in 16mm x 5mm flat iron frame & SWG 10, 50x50mm weld mesh complete with painting as directed) Special security grille fixed for windows complete to detail with frame in 16 x 5mm M.S flats Internal horizontal members in 12 x 5mm.M.S flat at 100mm crs. Properly welded and fixed to walls withrole plugs, screws inclusive of appl two coats of black

Unit m2 No m2 m2

Rs

Rate Cts

J-021

970.00 105.00

J-022 J-023

1,375.00 1,375.00 1,410.00 1,200.00 4,885.00 8,205.00

J-023B J-024 J-025 J-026 J-027 J-028

No No No No

m2

5,990.00

J-029

m2

3,765.00

J-030

m2

2,840.00

J-030a

m2

3,025.00

Page 32

Item No

Description Section 1 - BrickLayer/Mason Timber used in repairing door & window frames, Class. 1 100mm x 50mm Timber used in repairing door & window frames, Class. 1 100mm x 75mm. Timber used in repairing door & window frames ,Jack 100mm x 50mm. Timber used in repairing door & window frames ,Jack 100mm x 75mm. Timber used in repairing doors & windows , Cl.1up to 28mm thick planks. Timber used in repairing doors & windows, special up to 28mm thick planks. Window fully glazed 28mm thick sashes and nominal 95x70mm frame in cl 1 timber comp.with oxidized heavyduty furniture,3.0mm clr glass,including enamal paint. Window fully glazed 28mm thick sashes and 95mm x 70mm framein Jack timber comp.with oxidized heavy duty furniture,3.0mm clr glass,including enamal paint. Casement fasteners Iron oxidized supplied and fixed Door, window frames new, measured length of timberClass. 1, 95mm x 45mmSupplied & fixing. Door, window frames new, measured length of timberClass 1, 95mm x 70mm Supplied & fixing. Door, window frames new, measured length of timber Jack 95mm x 45mm Supplied & fixing. Door, window frames new, measured length of timber Jack 95mm x 70mm Supplied & fixing. Door, window 28mm thick new sash glassed or paneled cl.1 supplied and fixed

Unit

Rs

Rate Cts

J-031 J-032 J-033 J-034 J-035 J-036 J-037

m m m m m2 m2

745.00 1,040.00 770.00 1,065.00 3,985.00 6,110.00

m2

11,195.00

J-038

m2 No m m m

11,310.00 150.00 665.00 960.00 695.00

J-041 J-042 J-043 J-044 J-045

m m2

985.00

J-046

3,305.00

Page 33

Item No

Description Section 1 - BrickLayer/Mason Door, window 28mm thick sash new glassed or paneled Jack or special supplied and fixed Wicket gate sash in Jack or special timber 25mm thick supplied and fixed Wicket gate sash in class. 1 timber 25mm thick supplied and fixed Glass panes plain 3mm replaced complete. Glass panes plain 4.6mm replaced complete. Security weld mesh in open type buildings in GIweld mesh 50mm x 50mm SWG 10, welded on 40x40x5 mm MS angle frame complete with application of two coats brown enamel paint over two coats of anticorrosive paint to detail of Dr. No.(using available weld mesh ) Fixing security weld mesh on existing window frames complete with class. 1 timber beadings, andapplying two coats paint to match the exiting. Supply and fix plywood door sash approved quality(Painting & Locks measured separately) Anodized Aluminium hinged type shash door fan light on top with aluminium architectural sections with 10 - 15 micron coating glazed and pannelled with 3mm plastic coated ply board to both sides.At bottom and 4.6mm thick glass at top. Door size 1.5m x 2.4m Anodized Aluminium glazed window with openeble sash with aluminium architectural sections with 10 - 15 micron coating glazed 5 mm thick glass including all neccssary rubber beading,rawl plug etc. fan light on top

Unit m2 m2 m2 m2 m2

Rs

Rate Cts

J-047 J-048 J-049 J-050 J-051 J-052

5,865.00 6,120.00 4,945.00 1,475.00 1,795.00

m2

2,405.00

J-053

m2 m2

1,610.00 2,860.00

J-054 J-055

m2

9,175.00

J-056

m2

8,795.00

Page 34

Item No

Description Section 1 - BrickLayer/Mason Anodized Aluminium sliding window with aluminium architectural sections with 10 - 15 micron coating glazed with 5 mm thick glass including all neccssary rubber beading,rawl plug etc. (size 0.9m x 0.9m ) Anodized Aluminium partition with aluminium architectural sections with 10 - 15 micron coating glazed and pannelled with 3mm plastic coated plyboard to both sides.At bottom and 5mm thick glass at top. Casement stays 250mm Iron oxidized supplied and fixed.

Unit

Rs

Rate Cts

J-057

m2

6,410.00

J-058

m2 No

5,985.00 275.00

J-059

Page 35

Item No

Description Section 1 - BrickLayer/Mason Section 10 - Painter/Decorator

Unit

Rs

Rate Cts

P-001 P-002 P-003 P-004 P-005 P-006 P-007 P-008 P-009 P-010 P-011 P-012

Cement wash to walls of single storeyed building one coat. Cement wash to walls in single storeyed building two coat.

m2 m2

25.00 45.00 30.00 50.00 320.00 95.00 190.00 480.00 180.00 440.00 120.00

Cement wash externally to walls of building with upper floors, one coat. Cement wash externally to walls of building with upper floors, two coat. Prepare and apply one coat of alkali resisting primer and two coats of emulsion pain to walls. Paint emulsion after cleaning and preparing , one coat. Painting walls with emulsion paint two coats. Paint enamal after cleaning and preparing , new Wood work inclusive of primar undercoat. two coats. Paint enamal after cleaning and preparing , one coat. Paint enamal after cleaning and preparing , two coats. Paint removed to bare timber with blow lamp. Painting steel work anticorrosive paint after removing scales and wirebrushing, one coat. Painting steel work anticorrosive paint after removing scales and wirebrushing, two coats. Snowcem applied to wall surfaces one coats. Snowcem applied to wall surfaces two coats. Varnishing two coats with copal varnish after sand papering.

m2 m2 m2 m2 m2 m2 m2 m2 m2 m2 m2 m2 m2 m2

175.00 270.00 115.00 175.00 260.00

P-013 P-014 P-015 P-016

Page 36

Item No

Description Section 1 - BrickLayer/Mason Varnish Polyurethene applied to timber surfaces old work, one coat. Weathershield paint one coat applied on external surfaces. Weathershield paint two coats applied on external surfaces. Prepare and apply one coat of primer and two coats of weatheshild paint for new walls. White or colour washing to walls, in two storeyed building one coat. White or colour washing to walls after patching up and preparing surface one coat. White or colour washing to walls after scraping to original plaster including patching up, two coats. White washing to ceiling one coat. White washing to ceiling two coat.

Unit m2 m2 m2 m2 m2 m2 m2 m2 m2

Rs

Rate Cts

P-017 P-018 P-019 P-020 P-021 P-022 P-023 P-024 P-025

175.00 110.00 205.00 345.00 15.00 30.00 55.00 35.00 60.00

Page 37

Item No

Description Section 1 - BrickLayer/Mason Section 11 - Roofer

Unit

Rs

Rate Cts

R-001

Supplying and fixing new Asbestos roofing sheets confirming to SLS 9 on existing framework with new nut and bolts etc.(Frame work Measured Separately) Asbestos roofing sheets replacing with new sheets on existing frame work. Ceiling 19mm thick Lunumidella, tongued and grooved under side of rafters ,on existing timber frame work Ceiling, asbestos, flat fixed with clout headed nails to 100mm x 50mm joists & 50mm x 50mm bearers of cl. 1 timber including 35mm x 12mm cover fillets & 62mm x 35mm coves of approved timber.Rate to include 2 coats of emulsion paint underside of ceiling Ceiling, asbestos, flat fixed with clout headed nails to 100mm x 50mm joists,1.2m c/c & 50mm x 50mm bearers of at 0.6m c/c cl. 1 timber including 35mm x 12mm cover fillets & 62mm x 35mm coves of approved timber.Rate to include 2 coats of wood preservatives applied on joists and bearers Ceiling flat asbestos under side of rafters ,timber frame work measured seperately,rate includes for clout headed nails ,screws,beadings and mouldings. Ceiling flat asbestos under side of steel purlins ,50mm x 50mm Cl 1timber frame not more than 1.2m x 0.6m crs.includes for clout headed nails ,screws,beadings and mouldings and 6mm mild steel hanging hooks.Rate to include for apllication of wood preservative on timber frame Ceiling flat Lunumidella 20mm thick tongued and grooved complete with timber frame cl.1 100mm x 50mm joists at 0.6m crs,Rate to include for apllication of wood preservative on timber frame work twice. (Painting measured separately)

m2 m2 m2

675.00 755.00

R-002 R-003 R-004

915.00

m2

1,970.00

R-005

m2

1,795.00

R-006

m2

1,045.00

R-007

m2

2,285.00

R-008

m2

2,360.00

Page 38

Item No

Description Section 1 - BrickLayer/Mason Down pipes pvc 90mm dia supplied and fixedwith brackets at not exceeding 1.2m well secured to walls with Cl.1 timber plugs ,rates includes for specials Down pipes GI G24, 100mm with 20mm x3mm hoop iron brackets not exceeding 1.2m crs. inner side of the pipe applied with two coats hot tar blinded with sand, all other sides andbrackets applied with 2 coats anticorrosive paint, rate includes for special Gutters GI G22, 150mm with 12mm x 6mm flat iron brackets not exceeding 0.6m crs. inner side ofthe gutter applied with hot tar blinded with sand and all other sides and brackets appliedwith two coats anticorrosivepaint ,rate includesfor specials Gutters pvc squre type 150mm with pvc brackets not exceeding at 225mm Bracket fixed to valance board using 19mm brass screws,rate includes for specials. Plaster bands in 1:1:5 cement lime sand to tiled roof coloured to match Ridging asbestos pairs close fiting type fixed with necessary bolts. Ridging calicut patern tile bedded in cement and lime motar 1:1:4 coloured to match tiles Steel sections 2/ 62x62x6mm used in gable rafters purlins etc.complete with fixing,bolts,anticorrosive paint,and providing cleats where necessary .(concrete pad paid separately) Wood preservative applying one coat on roof structure in asbestos roof measured in plan area Wood preservative applying one coat on roof structure for calicut tile roof, measured in plan area Wood preservative applying two coats on roof structure for asbestos roof measured in plan area

Unit

Rs

Rate Cts

R-009

405.00

R-010

1,215.00

R-011

925.00

R-012

m m m

765.00 40.00 700.00

R-013 R-014 R-015

415.00

R-019

m m2 m2 m2

2,225.00 40.00

R-020 R-021

65.00 85.00

R-022

Page 39

Item No

Description Section 1 - BrickLayer/Mason Wood preservative applying two coats on roof structure for calicut tile roof measured in plan area Tiles calicut available laying on roof (for scattered laying) upto 10 tiles per building only. Tiles calicut new supplying and laying ( scattered laying) upto 25 tiles per building only. Tiles calicut shifting and relaying after cleaning (for measurements of area exceeding 25 tiles) Tiles, calicut pattern,supplied and laid in anybuilding Timber 50mm x 25mm reepers class 1 replacing with new including application of two coats wood preservative ( only up to 4.65m2 of roof area) Timber 50mm x 25mm reepers class 1 supplied and fixed including application of two coats woodpreservative ( only up to 4.6m2 of roof area) Timber 50mm x 50mm battons class 1 replacing with new including application of two coats woodpreservative ( only up to 4.6\m2 of roof area) Timber 50mm x 50mm battons class 1 supplied and fixed including application of two coats woodpreservative ( only up to 4.6m2 of roof area) Timber 50mm x 100mm joists / rafters class 1 replacing with new including application of two coats woodpreservative ( only up to 4.6m 2 of roof area) Timber 50mm x 100mm joists / rafters class 1 supplied and fixed including application of two coats woodpreservative ( only up to 4.6m 2 of roof area)

Unit m2

Rs

Rate Cts

R-023

130.00

R-024

No

35.00

R-025

No

45.00

R-026

No m2

15.00 555.00

R-027 R-028

145.00

R-029

140.00

R-030

305.00

R-031

300.00

R-032

705.00

R-033

670.00

Page 40

Item No

Description Section 1 - BrickLayer/Mason Timber beams,any size class 1 suppliedand fixed including application of two coats woodpreservative (only up to 4.6m2 of roof area) Timber boarding cl.1, 20mm to 25mm thick for valley gutters, flashings etc inclusive of two coats wood preservative ( only up to 4.6m 2 of roof area)

Unit

Rs

Rate Cts

R-034

m3

85,230.00

R-035

m2

1,875.00

R-036A Valance boards beaded 225mm x 20mm thick supplying and fixing Ginisapu , including two coats enamal paint (flat iron bracket measured seperately) . R-037 Valley gutters and flashing in GI sheets G22, including application of two coats hot tar and blinding with sand (timber board measured seperately) 900mm wide Ridge tiles available laid on roof on 1:3cement sand bedding coloured to match Timber available,cleaned and fixed on roof,size 50mm x 25mm Timber available,cleaned and fixed on roof,size 50mm x 50mm Timber available,cleaned and fixed on roof,size 100mm x 50mm Timber available,cleaned and fixed on roof,size 100mm x 75mm Timber available,cleaned and fixed on roof,size 125mm x 50mm Roof trusses available cleaned and placed inposition with supplying necessary bolts and templates,6m (20 L.ft) to 7.2m ( 24 L.ft) spans.

675.00

1,310.00

R-038

m m m m m m

280.00 25.00 25.00 120.00 120.00 120.00

R-039 R-040 R-041 R-042 R-043 R-044

No

4,680.00

Page 41

Item No

Description Section 1 - BrickLayer/Mason Roof trusses available cleaned and placed inposition with supplying necessary bolts and templates, 7.6m (25 L.ft) to 8.7m (29 L.ft) span Roof trusses available cleaned and placed inposition with supplying necessary bolts and templates, 9.1m (35.Lft)and above up to 12.2m ( 40 L.ft)span Fixing available steel purlins on roofs tructures complefte with necessary bolts,welding, cleaning and painting two coats anticorrosive paints etc. Roof asbestos. 62x62x6mm MS purlins not exceeding 1.35m crs.complete with necessary bolts / welds GI roofing bolts atnot more than 0.55m crs. on every purlin, applied with two coats anti corrosivepaint and the underside of sheets applied with two coats of lime wash.rate included 20 x 6 mm flate iron brackets for valance board at 0.6m c/c. Laminated aluminium foil, single side 8mm thick. without insulation layer, supplied and laid under the roof. as directed. Laminated aluminium foil,double side 8mm thick with insulation layer, supplied and laid under the roof as directed. Mineral fibre board ceiling 12mm thick suspended type with anodized aluminium T and and L sections complete as per detailed drawing.(ALUMINIUM FOIL MEASURED SEPERATELY) Web truss 7.6m ( 25 L.ft) span pitch 30 degree (600mm depth)

Unit

Rs

Rate Cts

R-045

No

5,400.00

R-046

No

6,120.00

R-047

140.00

R-048

m2

1,740.00

R-049

m2

360.00

R-050

m2

545.00

R-051

m2

1,755.00

R-052

Kg

175.00

Page 42

Item No

Description Section 1 - BrickLayer/Mason Roof truss steel 6.1m (20 L.ft) span S/F Drawing no CP/PC/K141/96/ST. Rate to include for all shop fabrication work,including cutting,drilling,bolting,riverting,welding,grinding, painting 2 coats anticorrosive delivering,unloading,hoisting,erecting & fixing Roof truss steel 7.6m (25 L.ft)span S/F Drawing no CP/PC/K141/96/ST. Rate to include for all shop fabrication work,including cutting,drilling,bolting,riverting,welding,grinding, painting 2 coats anticorrosive delivering,unloading,hoisting,erecting & fixing Roof truss steel 9.1m(30 L.ft)span S/F Drawing no CP/PC/K141/96/ST. Rate to include for all shop fabrication work,including cutting,drilling,bolting,riverting,welding,grinding, painting 2 coats anticorrosive delivering,unloading,hoisting,erecting & fixing Roof truss steel 10.6m (35 L.ft) span S/F Drawing no CP/PC/K141/96/ST. Rate to include for all shop fabrication work,including cutting,drilling,bolting,riverting,welding,grinding, painting 2 coats anticorrosive delivering,unloading,hoisting,erecting & fixing Roof truss steel 12.2m(40 L.ft) span S/F Drawing no CP/PC/K141/96/ST. Rate to include for all shop fabrication work,including cutting,drilling,bolting,riverting,welding,grinding, painting 2 coats anticorrosive delivering,unloading,hoisting,erecting & fixing

Unit

Rs

Rate Cts

R-053

No

28,000.00

R-054

No

35,620.00

R-055

No

45,500.00

R-056

No

62,920.00

R-057

No

72,810.00

Page 43

Item No

Description Section 1 - BrickLayer/Mason Section 12 - Surface/Plaster Work

Unit

Rs

Rate Cts

S-001

Black board in 1:3 cement sand including moulding at perimeter 20mm thick. 16mm thick plastering to wall Cement lime sand 1:1:5 finished smooth floating with lime putty.

m2 m2 m2 m2 m2

665.00

S-002

435.00 455.00 475.00 500.00

S-002A 16mm thick plastering to wall Cement lime sand 1:1:5 finished smooth floating with lime putty in first floor. S-002B 16mm thick plastering to wall Cement lime sand 1:1:5 finished smooth floating with lime putty in second floor. S-002C 16mm thick plastering to wall Cement lime sand 1:1:5 finished smooth floating with lime putty in third floor. S-003 Cement lime sand 1:1:5 finished smooth reveals 35mm to 150mm Cement lime sand plaster breaking damaged areas and re plastering 1:1:5., 20mm thick. Cement sand 1:3 plaster finished smooth with limeputty on concrete surfaces and soffits, 10mm thick. 16mm thick Cement sand 1:5 finished rough with wooden float.

m m2 m2 m2 m2 m2 m2 m m2

140.00

S-004

510.00 640.00 350.00

S-005 S-006

S-006A 16mm thick Cement sand 1:5 finished rough with wooden float Ground floor to first floor. S-006B 16mm thick Cement sand 1:5 finished rough with wooden float first floor to second floor. S-006C 16mm thick Cement sand 1:5 finished rough with wooden float Second floor to third floor. S-007 S-008 Ct. sand 1:5 finished rough, reveals 35mm to 150mm. Cement sand rough plaster breaking damaged areas and replastering 1:1:5.

365.00

390.00

400.00 115.00

465.00

Page 44

Item No

Description Section 1 - BrickLayer/Mason Plinth plaster 12mm thick, 1:3 cement sand finished in neat cement. Damp proof course 1:2 cement sand trowelled smooth 20mm thick and two coats hot tar blinded with sand. Plinth plaster 1:3 cement sand finished in colourcement. Rendering cement sand 1:3 ,20mm thick, finished smooth on walls. 12mm x 150mm skirting in cement sand 1:3 projected or flush to walls finished with floating including forming groove. Skirting in cement sand 1:3 finished in colour cement including forming groove.

Unit m2 m2 m2 m2

Rs

Rate Cts

S-009

355.00 695.00 360.00 515.00

S-010 S-011 S-012 S-013

235.00

S-014

255.00

Page 45

Item No

Description Section 1 - BrickLayer/Mason Section 13 - Water Supply/Plumb

Unit

Rs

Rate Cts

Note - All Brass taps, Ball valves, Gate valves, Stop valves, Etc. Peglar, or equaliant. W-001 Supplying & fixing 12mm(1/2") dia. Bidet spray ordinary approved quality Approved Cistern Ceramic low level supplied and fixed including 12mm(1/2") flexible hose Approved Cistern plastic English supplied and fixed with 12mm(1/2") flexible hose Approved Closet pedastal type with low level cistern, flushpipe, double plastic seat cover,12mm(1/2") angle valve and flexible hose, supplied and fixed in working order. Approved Semi Luxary, Toto or equivalent Closet pedastal type with low level cistern,flushpipe, double plastic seat cover,12mm(1/2") angle valve and flexible hose., supplied and fixed in working order. 1 No. Bowl type approved urinal with trap and spreaders complete to working order Approved Closet squatting type with trap ,medium size,supplied and fixed in working order includingconnection to sewer line complete with cementfoot rest, rate includes for breaking floor andconcreting and rendering in making damagedareas good. Approved New Closet squatting type with trap ,medium size,supplied and fixed in working order including connection to sewer line complete with cement foot rest. Mirror bathroom 500mm x 400mm approved quality with shelf,screws,plugs etc supplied and fixed

Plumber,

No

950.00

W-002

No No

3,000.00 3,225.00

W-003 W-004

No

14,905.00

W-005

No

26,515.00

W-007

No

1,805.00

W-008

No

5,420.00

W-009

No No

3,980.00 1,350.00

W-010

Page 46

Item No

Description Section 1 - BrickLayer/Mason Approved Sink stainless steel with single drain board with drain board with chromium plated wastewater chain, stay & waste plug (Tap.brackets, water & waste water connection & brick work measured separately) Approved Sink 600mm x 325mm x 175mm overall ceramic with 12mm(1/2") dia. chromiam plated piller tap,waste plug,chromiam plated waste chain & stay (water supply and waste connection & Brick work measured separately)

Unit

Rs

Rate Cts

W-011

No

5,390.00

W-012

No W-013 Approved Sink ceramic laboratory supplying and fixing complete with waste and brackets, chromiam plated waste ,chain, stay and waste plug.(Tap, water & waste water connection B/work measured separately) Suppling and fixing approved Coner wash basin ceramic with 12mm(1/2") dia. chromiam plated piller tap,waste plug,chain,stay including pedestal and brackets (Water connection and waste connection measured separately) Supplying and fixing 550mm X 400mm glazed fire clay pedastal type wash basin with 12mm(1/2") dia. chromiam plated piller tap, waste water plug, chromiam plated waste chain and stay. Including fixing approved wash basin on brackets/wooden plug.water and waste water connectio No W-015 A Approved semi luxary TOTO wash basin 550mm X 400mm glazed fire clay pedastal type wash basin with 12mm(1/2") dia. chromiam plated piller tap, waste water plug, chromiam plated waste chain and stay. Including fixing approved wash basin on brackets/wooden plug.water and waste water connection W-016 W-017 Removing and refixing available wash basin Stand post with 0.9m x 0.9m grade 20 concrete base and .15m x .15m Rcc pillar,12mm(1/2") brass bib tap,heavy quality inclusive of pvc 20mm pipeconnection, pipe measured seperately.

7,615.00

No

4,695.00

W-014

No

5,200.00

W-015

5,455.00

No No

14,990.00 1,590.00

No

5,970.00

Page 47

Item No W-018

Description Section 1 - storage ,1.8m . composite brick and reinforced Tank water concrete ,erected at up to 3m aboveground level.(trestle if any measured seperately)(rate to include for ball valve and connection) Supply and install water tank made of polymermaterials of approved quality on sand bed , 1000 l capacity (confirming to SLS 1174) Rate for only water tank. PVC pipe, valve fittings measured separately Supply and install water tank made of polymermaterials of approved quality on sand bed , 2000 l capacity (confirming to SLS 1174) Rate for only water tank. PVC pipe, valve fittings measured separately Supply and install water tank made of polymermaterials of approved quality on sand bed , 500 l capacity (confirming to SLS 1174) Rate for only water tank. PVC pipe, valve fittings measured separately Supplying & Fixing rubber rings in outlets for Wash basin,Sink, etc Supplying and fixing 12mm(1/2") dia.approved chromiam plated heavy quality swan neck typpe piller tap with 01 No. P.V.C. F/Socket to wash basin/sink Supplying and fixing 12mm(1/2") dia.approved brass heavy quality tap with 1/2" dia. P.V.C. valve socket Supplying and fixing 12mm(1/2") dia. approved plastic tap with 1 No. F/socket P.V.C Supplying & fixing 12mm(1/2" dia.) ,150mm approved shower rose,chromium plated Supplying and fixing 12mm(1/2") dia.approved shower rose best quality Indian or equalant Pipes pvc supplied and laid with specials,size 50mm dia. in wastes of sinks. Type 1000
3 BrickLayer/Mason

Unit

Rs

Rate Cts

No

45,390.00

W-019

No

14,895.00

W-020

No

23,290.00

W-021

No No

8,625.00 125.00

W-022 W-023

No No No

2,020.00 1,385.00 275.00

W-024 W-025 W-026

No No m

450.00 1,180.00 580.00

W-027 W-028

Page 48

Item No W-029

Description Section 1 supplied - BrickLayer/Mason Pipes pvc and laid with specials,size 50mm dia.rate includes for cutting trencthes and backfilling. (type 1000), depth not less than 450mm Pipes pvc type 1000 supplied and laid with specials, size 40mm dia. in waste of wash basins. Pipes pvc type 1000 supplied and laid with specials, size 40mm dia. rate includes for cutting trencthes and back filling, depth not less than 450mm Pipes pvc supplied and laid with specials,size 32mm dia. type 1000 rate includes for cutting trencthes andback filling, depth not less than 300mm to 450mm Pipes pvc supplied and laid with specials,size 20mm dia. Type 1000 rate includes for cutting trenches and back filling, depth not less than 300mm to 450mm Pipes pvc supplied and laid with specials, size 63mm dia.in waste water lines, vent etc. (type 400) Pipes pvc supplied and laid with specials,size 63mm dia. Pipes pvc supplied and laid with specials,size 25mm dia.Type 1000 rate includes for cutting trenches and backfilling, depth 300mm to 450mm Valve chamber 225mm x225mm x 225mm in concrete, complete with RCC. lid PVC Elbow supplied and fixed size 20mm dia. PVC Elbow supplied and fixed size 25mm dia. PVC Elbow supplied and fixed size 32mm dia. PVC Elbow supplied and fixed size 40mm dia. PVC Elbow supplied and fixed size 50mm dia. PVC Elbow supplied and fixed size 63mm dia. PVC Bend supplied and fixed size 20mm dia. PVC Bend supplied and fixed size 25mm dia.

Unit

Rs

Rate Cts

m m

490.00 370.00

W-030 W-031

375.00

W-032

290.00

W-033

145.00

W-034

m m

555.00 770.00

W-035 W-036

m No No No No No No No No No

225.00 1,205.00 45.00 50.00 80.00 110.00 190.00 280.00 55.00 70.00

W-037 W-038 W-039 W-040 W-041 W-042 W-043 W-044 W-045

Page 49

Item No

Description Section 1 - BrickLayer/Mason PVC Bend supplied and fixed size 32mm dia. PVC Bend supplied and fixed size 40mm dia. PVC Bend supplied and fixed size 50mm dia. PVC Bend supplied and fixed size 63mm dia. PVC Socket supplied and fixed size 25mm dia. PVC Socket supplied and fixed size 20mm dia. PVC Socket supplied and fixed size 32mm dia. PVC Socket supplied and fixed size 40mm dia. PVC Socket supplied and fixed size 50mm dia. PVC Socket supplied and fixed size 63mm dia. Gate valve ,Brass, supplied and fixed, size 1/2" dia. heavy quality. Gate valve ,Brass,supplying and fixing, size 1" dia. heavy quality, Valve gate Brass, supplied and fixed, size 1 1/4" dia' heavy quality. Valve gate Brass, supplied and fixed, size 1 1/2" dia. heavy quality. Valve gate Brass, supplied and fixed, size 2" dia. heavy quality. Stop cock brass supplied and fixed, size 1/2" dia. heavy quality. Stop cock brass supplied and fixed, size 3/4" dia. heavy quality. Brass stop cock supplying and fixing, size 1" dia. heavy quality. Stop cock ,Brass,supplying and fixing, size 1 1/4" dia. heavy quality,

Unit No No No No No No No No No No No

Rs

Rate Cts 90.00 110.00 260.00 385.00 55.00 30.00 70.00 95.00 105.00 215.00 720.00

W-046 W-047 W-048 W-049 W-050 W-051 W-052 W-053 W-054 W-055 W-056 W-057

No No No No No No No No

1,395.00 2,500.00 2,890.00 4,775.00 795.00 1,250.00 1,875.00 450.00

W-058 W-059 W-060 W-061 W-062 W-063 W-064

Page 50

Item No W-065 W-066 W-067 W-068 W-069 W-070 W-071 W-072

Description Section 1 plastic - BrickLayer/Mason Stop cock (watertec or equivalent) supplied and fixed, size 3/4" dia. Stop Cock Plastic (water Tec or equivalent) supplying and fixing, size 1" dia. Ball valve ,Brass, supplied and fixed, size 1/2" dia. Ball valve supplying and fixing, size 3/4" dia. Ball valve ,Brass,supplying and fixing, size 1" dia. PVC Tee supplied and fixed size 20mm dia. PVC Tee supplied and fixed size 25mm dia. PVC Tee supplied and fixed size 32mm dia.

Unit No No No No No No No No

Rs

Rate Cts 365.00 400.00 985.00

1,595.00 3,775.00 85.00 100.00 125.00

Page 51

Item No

Description Section 1 - BrickLayer/Mason Section 14- Transport Shedule

Unit

Rs

Rate Cts

Y-001

Transport of metal and sand beyond 10 km per km, rate for one cube. Transport of Cement beyond 10 km per km, rate for one bag (50kg) Transport of Steel beyond 10 km per km, rate for 1000kg.

Km km km

77.00 0.77 15.40 38.50 500.00 38.00

Y-002 Y-003 Y-004 Y-005 Y-006 Y-007

Transport of Bricks beyond 10 km per km, rate for 1000Nos. Head transport of metal and sand beyond 100m (rate for one cube ) per every 100m

Km 100m

Head transport of Cement or steel beyond 100m (rate for 50kg ) per every 100m 100m Head transport of brick beyond 100m (rate for 1000No) per every 100m

100m

624.00

Page 52

C-016 No 1.01 1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.1 1.11

Swan timber formwork in column in ground floor Item Description Planks 1" thick cl.11 Timber 2"x2" cl.11 Timber 2"x1" cl.11 wire nails 2" Skilled labour Unskilled labour Mould oil Round Timber 3" dia. Skilled labour Unskilled labour 12mm , 15" long bolts and nuts Item Ref A0-172 A0-154 A0-152 A0-458 A0-001 A0-002 A0-460 A0-666 A0-001 A0-002 A0-662 Total for Rate for 1 Profits & O/H Rate(Say) Swan timber form works for underside of floor slab Item Ref A0-459 A0-457 A0-458 A0-001 A0-002 A A Analysis for 0.15 Unit Quantity Sq.ft 4.53 L.ft 4.275 L.ft 3 kg 0.125 day 0.125 day 0.125 Ltr 0.5 L.ft 3.5 day 0.17 day 0.3 No 0.2 0 0 0 20.% Sqft Rate 55.36 24.06 7.23 165.00 650.00 450.00 30.00 6.66 650.00 450.00 86.00 Amount 250.78 102.86 21.69 20.63 81.25 56.25 15.00 23.31 110.50 135.00 17.20 834.46 5,563.08 1,112.62 6,675.70

718.67

C-017 No 1.01 1.02 1.03 1.04 1.05 1.06 1.06

Item Description Timber planks 1" Class II 4 X 2 Runners at 2' centers wire nails 2" Skilled labour Unskilled labour Allow 20% of Items ( 1.05 ) for Repairs Allow 5% of Items ( 1.04,1.05,1.1,1.11,1.14,1.15 ) for scafolding Round Timber 3" dia. Timber 2"x2" cl.11 Timber planks 1" Class II Skilled labour Unskilled labour Mould oil wire nails 2" Skilled labour Unskilled labour Wedges

2 Analysis for Unit Quantity Sq.ft 55 L.ft 30.25 kg 0.45 day 0.75 day 0.75

Sq Rate 55.36 40.00 165.00 650.00 450.00 67.50 208.13

Amount 3,044.80 1,210.00 74.25 487.50 337.50 67.50 208.13

1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 1.16

A0-666 A0-154 A0-459 A0-001 A0-002 A0-460 A0-458 A0-001 A0-002 A0-685 Total for Rate for 1 Profits & O/H Rate(Say)

L.ft L.ft Sq.ft day day Ltr kg day day No. 0 0 20.%

115 11 5.5 1 4 4 0.9 0.5 2 20.33 0

6.66 24.06 55.36 650.00 450.00 30.00 165.00 650.00 450.00 10.00

765.90 264.66 304.48 650.00 1,800.00 120.00 148.50 325.00 900.00 203.30 10,911.52 5,455.76 1,091.15 6,546.91

704.80

C-018 No 1.01 1.02 1.03 1.04 1.05 1.06 1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15

Swan timber form work for concrete beams Item Description Timber planks 1" Class II Timber 2"x2" cl.11 wire nails 2" Skilled labour Unskilled labour Allow 10% of Items ( 1.01, 1.02 ) for Repairs Allow 10% of Items ( 1.03 ) for scafolding Round Timber 3" dia. Timber planks 1" Class II Skilled labour Unskilled labour Mould oil Timber 2"x1" cl.11 Timber 4"x2" cl.11 Timber 2"x2" cl.11 Allow 3% of Items ( 1.04, 1.05, 1.09 ) for tools Item Ref A0-459 A0-154 A0-458 A0-001 A0-002 A A A0-666 A0-459 A0-001 A0-002 A0-460 A0-152 A0-156 A0-154 A A Total for Rate for 1 Profits & O/H Rate(Say) 0.55 Analysis for Unit Quantity Sq.ft 15 L.ft 11.25 kg 0.225 day 0.25 day 0.25 Sq Rate 55.36 24.06 165.00 650.00 450.00 112.07 112.07 6.66 55.36 650.00 450.00 30.00 7.23 43.89 24.06 25.50 25.50 0 0 20.% 0 Amount 830.40 270.68 37.13 162.50 112.50 112.07 112.07 123.21 55.36 325.00 337.50 60.00 43.38 329.18 48.12 25.50 25.50 3,010.09 5,472.88 1,094.58 6,567.46

L.ft Sq.ft day day Ltr L.ft L.ft L.ft

18.5 1 0.5 0.75 2 6 7.5 2

1.15 Allow 3% of Items ( 1.1 ) for Repairs

707.01

C-019

Formwork in portal frames four time use the suttering = 80Sqft x 1/4 = 20Sqft No Item Description 1.01 Planks 1" thick cl.11 1.02 Timber 2"x2" cl.11

Item Ref A0-172 A0-154

Analysis for 0.75 Unit Quantity Sq.ft 22.5 L.ft 10

Sq Rate 55.36 24.06

Amount 1,245.60 240.60

1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.1

Timber 2"x1" cl.11 Timber planks 1" Class II wire nails 2" Skilled labour Unskilled labour Mould oil Wedges (2" X 2" timber Class II ) Round Timber 3" dia. Allow 2.5% of Items ( 1.06,1.07 ) for tools Allow 10% of Items ( 1.06,1.07 )for Repairs Allow 5% of Items ( 1.06,1.07 ) for scaffoling

A0-152 A0-459 A0-458 A0-001 A0-002 A0-460 A0-663 A0-666

L.ft Sq.ft kg day day Ltr L.ft L.ft

16.25 1.5 0.5 1.5 2.5 2 3 40

7.23 55.36 87.00 650.00 450.00 30.00 10.00 6.66 52.50 210.00 105.00

C-020

Total for 0 0 Rate for 1 0 Profits & O/H 20.% Rate(Say) Formwork in lintels and ground concrete works, plinth beams. Analysis for 0.34 No Item Description Item Ref Unit Quantity 1.01 Timber planks 3/4"to 1" cl.11 A0-165 Sq.ft 8.5

117.49 83.04 43.50 975.00 1,125.00 60.00 30.00 266.40 52.50 210.00 105.00 4,554.13 6,072.17 1,214.43 7,286.60

784.43

Sq Rate 55.36

Amount 470.56

1.02 Skilled labour 1.03 Timber 2"x2" cl.11

A0-001 A0-154 Total for Rate for 1 Profits & O/H Rate(Say)

day L.ft 0 0 20.%

0.5 6 0

650.00 24.06

325.00 144.36 939.92 2,764.47 552.89 3,317.36

357.13

E-026 No

Quarry dust filling ( cushion ) under foundation Item Description 1.04 Quarry dust 1.05 Unskilled labour Analysis for 1 Unit Quantity Cu 1.1 A0-002 day 0.5 Total for 0 0 Rate for 1 0 Profits & O/H 20.% Rate(Say) Item Ref Cu Rate 1,900.00 450.00 Amount 2,090.00 225.00 2,315.00 2,315.00 463.00 2,778.00

G-029

Cutting turf sods, loading to hand carts and transporting up to 30 yards, laying and watering for 30days. (Royalty for turf, pegging and transport beyond 30 yards paid separately) No 1.01 1.02 1.03 1.04 1.05 Item Description Unskilled labour Unskilled labour Skilled labour water Unskilled labour Item Ref A0-002 A0-002 A0-001 A0-453 A0-002 Total for Rate for 1 Profits & O/H Rate(Say) Analysis for 3 Unit Quantity day 1 day 0.5 day 2 gal 60 day 1 0 0 0 20.% Sqr Rate 450.00 450.00 650.00 0.75 450.00 Amount 450.00 225.00 1,300.00 45.00 450.00 2,470.00 823.33 164.67 988.00

J-057

Anodized Aluminium hinged type shash door fan light on top with aluminium architectural sections with 10 - 15 micron coating glazed and pannelled with 3mm plastic coated ply board to both sides.At bottom and 5mm thick glass at top. Door size 5 X 8-10 No 1.01 1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 1.16 1.17 1.18 1.19 1.2 1.21 1.22 1.23 1.24 1.25 1.26 1.27 1.28 1.29 Item Description Item Ref Anodize Aluminium Architectural section No 7631 / A0-100 Anodize Aluminium Architectural section No 7632/4 A0-101 Anodize Aluminium Architectural section No 7633/4 A0-102 Anodize Aluminium Architectural section No 7634/4 A0-103 Anodize Aluminium Architectural section No 4449/1 A0-104 Anodize Aluminium Architectural section No 4445/1 A0-105 Anodize Aluminium Architectural section No 4447/2 A0-106 Anodize Aluminium Architectural section No 4444/3 A0-108 Anodize Aluminium Architectural section No 4446/4 A0-109 Anodize Aluminium Architectural section No 4448/5 A0-110 Anodize Aluminium Architectural section No 4457/1 A0-111 Door Handle A0-530 Door Lock A0-531 MOHAIR (small) A0-532 1"x 1" thick angle A0-533 Tread bars A0-534 4" X 3" Hinges A0-535 Glass(5mm nominal thick) A0-191 3mm thick PVC ply board A0-536 5/32 X 1/2 G.S.K. rivets A0-537 rubber A0-538 Screws 2" X 8 A0-540 Silicon A0-541 Flush bolt A0-542 Fabricator A0-543 Unskilled labour A0-002 Pop rivets 5/32 X 3/8 A0-547 Allow 3% of Items ( 1.25, 1.26 ) for wastage A Allow 10% of Items ( 1.01, 1.02, 1.03, 1.04, 1.05, A 1.06, 1.07, 1.08, 1.09, 1.1, 1.11 ) for tools Total for Profits & O/H Rate for 1 Rate(Say) Analysis for 44.15 Unit Quantity L.ft 25 L.ft 5 L.ft 5 L.ft 7 L.ft 14 L.ft 14 L.ft 5 L.ft 5 L.ft 5 L.ft 20 L.ft 20 Pairs 2 No 1 L.ft 33 L.ft 5 No 2 No 6 Sq.ft 59 Sq.ft 30 No. 30 L.ft 46 No 40 Tube 1 No 2 day 2.5 day 2.5 No 250 Sq.ft Rate 93.00 79.54 40.24 54.30 174.26 182.50 179.80 213.55 236.50 25.30 27.00 450.00 600.00 4.57 48.00 110.00 90.00 59.00 16.41 81.00 8.23 50.00 265.00 400.00 700.00 400.00 0.75

795.25

2,325.00 397.70 201.20 380.10 2,439.64 2,555.00 899.00 1,067.75 1,182.50 506.00 540.00 900.00 600.00 150.81 240.00 220.00 540.00 3,481.00 492.30 2,430.00 378.58 2,000.00 265.00 800.00 1,750.00 1,000.00 187.50 82.50 1,249.39

44.15 20.%

Sq.ft

29,260.97 5,852.19 35,113.16 795.32 795.25