25 x 25 x 2 SHS (GRADE 350W) 25 x 25 x 2 SHS 30 x 30 x 5 L SLOTS TO BE PROVIDED AS ALTERNATIVE FOR ATTACHMENT WITH U-BOLTS WHEN REQUIRED BY ENGINEER 30 x 30 x 5 L SLOTS TO BE PROVIDED AS ALTERNATIVE FOR ATTACHMENT WITH U-BOLTS WHEN REQUIRED BY ENGINEER

25 x 25 x 2 SHS

25 x 25 x 2 SHS

500

Provincial and EPWP Logos

25 x 25 x 2 SHS (GRADE 350W) 50 30 x 30 x 5 L 30 x 30 x 5 L

Contract No: 000 000 000 FLOOD DAMAGE PROJECT MHLONTHLO LMA
CONSULTING ENGINEERS TELEPHONE NUMBER

Text to be 100mm hign Helvetica Medium Upper and Lower case letters in Black

2049

615

25 x 25 x 2 SHS (GRADE 350W) 30 x 30 x 5 L 30 x 30 x 5 L

50

160

Text to be 50mm high Helvetica Medium upper case letters in Black Horozontal lines to be 8mm thick Text to be 75mm high Helvetica Medium upper case letters in Black Background to be White

MJT CONSULTING
285

+27 (0) 83 560 3161

25 x 25 x 2 SHS (GRADE 350W) 30 x 30 x 5 L 30 x 30 x 5 L

225

LOGO

CONTRACTOR

Text to be 50mm high Helvetica Medium upper case letters in Black Text to be 75mm high Helvetica Medium upper case letters in Black

A.B NAME

50

30 x 30 x 5 L SLOTS TO BE PROVIDED AS ALTERNATIVE FOR ATTACHMENT WITH U-BOLTS WHEN REQUIRED BY ENGINEER 25 x 25 x 2 SHS (GRADE 350W)

30 x 30 x 5 L SLOTS TO BE PROVIDED AS ALTERNATIVE FOR ATTACHMENT WITH U-BOLTS WHEN REQUIRED BY ENGINEER

32

Position of the Pole : 475 32 50 390 2260 65 50 32 = = =

Position of the Pole : 475

2879

FRONT ELEVATION
SCALE 1:10

REAR SIDE BRACING


SCALE 1:10

SIGN BOARD DETAIL

TABLE 1

ERECTION DETAILS

TYPE POST

UPRIGHT 100mm 180mm 100mm x 4mm

STAY 80mm

D 600mm 1000mm 1000mm

B 850mm 1450mm 1450mm

Contract No: FLOOD DAMAGE PROJECT MHLONTHLO LMA


CONSULTING ENGINEERS TELEPHONE NUMBER

TIMBER POST AND STAY TIMBER POST D SECTION STEEL POST

MJT CONSULTING
LOGO

+27 (0) 83 560 3161


30x30x5 L

CONTRACTOR

A.B NAME
Table 1

D
1:5 SLOPE 4.5mm RIVETS @ 150mm c/c MAX

3 TYPICAL 1:10 MAX SLOP E

M10 GALVANISED BOLT OR U BOLT 1:12 SOILCRETE (OR AS REQUIRED BY ENGINEER) 30x30x5 L (GRADE 350W) 30x30x5 L (GRADE 350W) GRAVEL LAYER FOR RIVETS @ 150mm c/c MAX 25x25x2 TIMBER POST OR D SECTION STEEL POST (SEE TABLE 1) 4.5mm RIVETS @ 150mm c/c MAX (COLOUR IDENTICAL TO THAT OF SIGN BOARD) MAX SPACING = 150mm

TIMBER POST OR D SECTION STEEL POST (SEE TABLE 1) M10 GALVANISED BOLT OR U BOLT

SLOTS TO BE PROVIDED AS ALTERNATIVE FOR ATTACHMENT WITH U-BOLTS WHEN REQUIRED BY ENGINEER

25 x 25 x 2 SHS

Border all around to be 32mm thick, Orange =

12mm HOLE

25x25x2 Square Hollow Section

30x30x5 L

C L

FOUNDATION DETAIL N.T.S.

SIDE ELEVATION N.T.S.

PLAN: SECTION D-D Scale 1 : 5

ELEVATION ERECTION BRACKET Scale 1 : 5

FRONT ELEVATION
SCALE 1 : 20

SIDE ELEVATION
SCALE 1 : 20 client consultant 33 BONZA BAY ROAD BEACON BAY EAST LONDON 5241 Team Members Designed Drawn Checked Approved Mr R. Netshiongolwe Mr R. Netshiongolwe Mr T. Ramatsea (Pr Eng) Mr T. Ramatsea (Pr Eng) Drawing Tittle

FIXING DETAILS APPROVED BY DETAIL OF SIGN BOARD


(Layout and Assembly details)
for HEAD OF DEPARTMENT DATE CONSULTANT JOB No. MJT2010/03 SCALE AS SHOWN DRAWING No. 009 SHEET OF SHEET 01 01 REVISION No. 00

SCALE ON REDUCED DRAWING

1 100mm ON ORIGINAL DRAWING No

08 Jan 2013 DATE

PROJECT MANAGEMENT OFFICE AMENDMENTS


SHOP 8 BEACON BAY CROSSING BONZA BAY ROAD EAST LONDON 5208

Email: mjt@mjtconsulting.co.za

DRAWING NUMBER: