0.75 Ton
1 Ton
FDXS09DVJU FDXS12DVJU 4,400 - 8,500 - 8,500 4,800 - 11,500 - 11,500 4,400 - 10,000 - 10,000 4,800 - 11,500 - 11,500 305/280/260 305/280/260 35/33/31 35/33/31 35/33/31 35/33/31 1/4 1/4 3/8 3/8 VP20(O.D. 1-1/32, I.D. 25/32) 7 7/8 x 27 9/16 x 24 7/16 47.0 47.0
Indoor Units - FTXS_HVJU Wall Mounted Units For use with RX_F(A)VJU (Standard Efficiency) or RXS_D(A)VJU (High Efficiency) Models
Model Cooling Capacity (min. - nom. - max.) Heating Capacity (min. - nom. - max.) Moisture Removal Airflow - Dry (H/M/L) Sound Pressure Level - Cooling (H/M/L) Sound Pressure Level - Heating (H/M/L) Liquid (O.D.) Piping Gas (O.D.) Connections Condensate (O.D.) Dimensions (H x W x D) Weight Btu/h Btu/h Pt/h cfm dB(A) dB(A) in. in. in. in. lbs. FTXS09HVJU FTXS12HVJU 4,400 - 8,500 - 9,500 4,800 - 11,500 - 12,000 4,400 - 10,000 - 11,000 4,800 - 11,500 - 13,000 2.3 3.2 253/220/187 286/237/187 38/32/25 40/33/26 38/33/28 39/34/29 1/4 1/4 3/8 3/8 11/16 11/16 10 3/4 x 30 7/8 x 7 11/16 16.6 16.6
1.25 Ton
FTXS15HVJU* 3,200 - 15,000 - 15,000 3,200 - 18,000 - 21,200 3.4 515/459/402 45/41/36 44/40/35 1/4 1/2 11/16 26.5
1.5 Ton
FTXS18HVJU 3,200 - 18,000 - 18,000 3,200 - 21,600 - 24,000 4.3 609/529/448 45/41/36 44/40/35 1/4 1/2 11/16 11 7/16 x 41 5/16 x 9 3/8 26.5
2 Ton
FTXS24HVJU 3,200 - 22,000 - 22,000 3,200 - 24,000 - 25,400 6.3 586/532/477 46/42/37 46/42/37 1/4 5/8 11/16 26.5
Outdoor Units - RX_F(A)VJU Heat Pump (Standard Efficiency) For use with the FTXS_HVJU Models
Model Compressor Type Energy Efficiency Energy Efficiency Power Consumption - Cooling Power Consumption - Heating Sound Pressure Level - Cooling/Heating Operating Range - Cooling (outdoor-db) Operating Range - Heating (outdoor-db) Operation Current - Cooling Operation Current - Heating Max. Piping Length Max. Height Difference Dimensions (H x W x D) Weight RX09FAVJU SEER HSPF W W dB(A) F F A A ft. ft. in. lbs. RX12FAVJU 13 13 7.7 7.7 810 1,310 1,080 1,060 48/49 49/51 14 - 115 14 - 115 5 - 77 5 - 77 4.38 5.87 5.03 5.02 65 65 49 49 21 5/8 x 30 1/8 x 11 1/4 74 80 RX15FVJU RX18FVJU Hermetically sealed swing type compressor 13 13 7.7 7.7 1,320 1,710 1,690 2,160 51/51 51/51 14 - 115 14 - 115 5 - 77 5 - 77 5.83 7.49 7.4 9.4 98 98 66 66 28 15/16 x 32 1/2 x 11 13/16 117 117 RX24FVJU 13 7.7 5,555 2,805 54/54 14 - 115 5 - 77 11.15 12.23 98 66 121
Outdoor Units - RXS_D(A)VJU Heat Pump (High Efficiency) For use with FTXS_HVJU & FDXS_DVJU Models
Model Compressor Type Energy Efficiency Energy Efficiency Power Consumption - Cooling Power Consumption - Heating Sound Pressure Level - Cooling/Heating Operating Range - Cooling (outdoor-db) Operating Range - Cooling (outdoor-db) (with optional wind baffle) Operating Range - Heating (outdoor-db) Operation Current - Cooling Operation Current - Heating Max. Piping Length Max. Height Difference Dimensions (H x W x D) Weight RXS09DAVJU SEER HSPF W W dB(A) F F F A A ft. ft. in. lbs. 16 8.8 810 1,080 48/49 14 - 115 0-115 0 - 77 4.38 5.03 65 49 74 RXS12DAVJU 16 8.8 1,310 1,060 49/51 14 - 115 0-115 0 - 77 5.87 5.02 65 49 80 RXS15DVJU* Hermetically sealed swing type compressor 17 10.1 1,320 1,690 51/51 14 - 115 0-115 0 - 77 5.83 7.4 98 66 117 RXS18DVJU 16.3 7.7 1,710 2,160 51/51 14 - 115 0-115 0 - 77 7.49 9.4 98 66 28 15/16 x 32 1/2 x 11 13/16 117 RXS24DVJU 15 9.2 2,555 2,805 54/54 14 - 115 0-115 0 - 77 11.15 12.23 98 66 121
n Energy efficient n Home-leave temperature set-back operation n 24-hour timer n I ntelligent Eye (Movement sensor) on FTXS
n R-410A precharged for piping up to 33ft. n Long piping length up to 98ft. n Quiet operation n R eliable and unique Daikin Swing Compressor n Backlit Wireless Remote Controller (New) n O ptional Wired Remote Controller (New) n C elsius or Fahrenheit selection available for
www.daikinac.com
Quaternity
Quaternity Indoor Units - FTXG_HVJU Wall Mounted Units. For use with RXG_HVJU Models
Model Cooling Capacity (min. - nom. - max.) Heating Capacity (min. - nom. - max.) Moisture Removal Airflow - Dry Sound Pressure Level - Cooling (H/M/L) Sound Pressure Level - Heating (H/M/L) Liquid (O.D.) Piping Gas (O.D.) Connections Condensate (O.D.) Dimensions (H x W x D) Weight Btu/h Btu/h Pt/h cfm dB(A) dB(A) in. in. in. in. lbs. FTXG09HVJU 5,300 - 9000 - 12,300 4,400 - 12,000 - 18,000 3.38 438 42/33/26 42/35/28 1/4 3/8 11/16 31 FTXG12HVJU 5,300 - 12,000 - 15,700 4,400 - 16,000 - 19,100 4.86 470 43/35/27 43/36/29 1/4 3/8 11/16 12 x 35 1/32 x 8 7/32 31 FTXG15HVJU 5,300 - 15,000 - 18,000 4,400 - 18,000 - 21,200 5.92 494 45/37/29 44/38/31 1/4 3/8 11/16 31
The Quaternity system is designed to maximize the comfort level from its user even under the most challenging weather conditions. The products main 4 pillars are: 1. E nvironmentally conscious: high energy efficiency and use of R-410A refrigerant 2. C omfort: Dehumidification function / Quick warming function / Comfort air flow 3. I ndoor Air Quality: Flash streamer air purifier / Titanium apatite photo catalytic air purifying filter 4. U ser Friendly: Easy to use controls and simple operation
Quaternity Outdoor Units - RXG_HVJU For use with the FTXG_HVJU Models
Model Compressor Type Energy Efficiency Energy Efficiency Energy Efficiency Energy Efficiency Power Consumption - Cooling Power Consumption - Heating Sound Pressure Level - Cooling/Heating Operating Range - Cooling (outdoor-db) Operating Range - Heating (outdoor-db) Operation Current - Cooling Operation Current - Heating Max. Piping Length Max. Height Difference Dimensions (H x W x D) Weight RXG09HVJU SEER EER HSPF COP W W dB(A) F F A A ft. ft. in. lbs. 22 15.8 11 4.51 570 780 46/46 14 - 109 -4 - 75 3.1 4.04 33 26 99 RXG12HVJU Hermetically sealed swing type compressor 22 14 10.55 4.04 860 1,160 49/48 14 - 109 -4 - 75 4.3 5.64 33 26 22 3/8 X 31 9/32 X 11 7/32 99 RXG15HVJU 21 12.9 10 3.99 1,160 1,320 50/50 14 - 109 -4 - 75 5.64 6.36 33 26 99
Quaternity Units are ARI 210/240 performance certified and have earned the Energy Star label Controlling the humidity set-point in the room allows for a comfortable condition without the need for a very low set-point temperature. With the unique Quaternity solution controlling the dehumidification as well as temperature, enhanced user comfort is possible. Also, this feature prevents inefficient overcooling, which helps to save on energy use.
Room temperature 77F Humidity 80% Room temperature 77F Humidity 50%
86
104F
Quaternitys dehumidification operation
86
104F
Deodorizing Filter: odors are absorbed and broken down before the air is returned into the room
n Ability to dehumidify to a relative humidity set-point (RH%) n Flash Streamer air cleaner for improved IAQ n W ireless infra-red remote controller shows ambient
www.daikinac.com
Multi-Split Systems
(208 - 230V / 1Ph / 60Hz) Indoor Units - CTXS_HVJU Wall Mounted Units For use with 2MXS_GVJU or 4MXS_GVJU Models
Model Rated Capacity* Moisture Removal Airflow - Dry (H/M/L) Sound Pressure Level - Cooling (H/M/L) Sound Pressure Level - Heating (H/M/L) Dimensions (H x W x D) Weight Condensate Drain Connection Btu/h Pt/h cfm dB(A) dB(A) in. lbs. in.
0.75 Ton
1 Ton
1.25 Ton
1.5 Ton
CTXS09HVJU CTXS12HVJU 9,000 12,000 n/a n/a 388/335/283 519/436/353 44/40/35 45/41/36 44/39/34 45/40/35 11 7/16 x 31 5/16 x 9 3/8 20 20 11/16 11/16
Indoor Units - FTXS_HVJU Wall Mounted Units For use with 2MXS_GVJU or 4MXS_GVJU Models
Model Rated Capacity* Moisture Removal Airflow - Dry (H/M/L) Sound Pressure Level - Cooling (H/M/L) Sound Pressure Level - Heating (H/M/L) Dimensions (H x W x D) Weight Condensate Drain Connection Btu/h Pt/h cfm dB(A) dB(A) in. lbs. in. FTXS15HVJU FTXS18HVJU 15,000 18,000 3.4 4.3 515/459/402 609/529/448 45/41/36 45/41/36 44/40/35 44/40/35 11 7/16 x 41 5/16 x 9 3/8 26.5 26.5 11/16 11/16
Indoor Units - FDXS_DVJU Slim Duct Built-In Concealed Ceiling Unit For use with 2MXS_GVJU or 4MXS_GVJU Models
Model Rated Capacity* Airflow - Dry (H/M/L) Sound Pressure Level - Cooling (H/M/L) Sound Pressure Level - Heating (H/M/L) Dimensions (H x W x D) Weight Condensate Drain Connection Btu/h cfm dB(A) dB(A) in. lbs. in. FDXS09DVJU FDXS12DVJU 9,000 12,000 305/280/260 305/280/260 35/33/31 35/33/31 35/33/31 35/33/31 7 7/8 x 27 9/16 x 24 7/16 47 47 1-1/32 1-1/32
Outdoor Units - MXS_GVJU Heat Pump For use with CTXS_HVJU, FTXS_HVJU and FDXS_DVJU Models
Model Rated Capacity* Compressor Type Sound Pressure Level - Cooling/Heating Operating Range - Cooling (outdoor-db) Operating Range - Heating (outdoor-db) Pipe Liquid (O.D.) Gas (O.D.) Connections Max. Piping Length (Per Unit) Max. Height Difference Dimensions (H x W x D) Weight Btu/h dB(A) F F in. in. ft. ft. in. lbs.
1.5 Ton
2.5 Ton
2MXS18GVJU** 4MXS32GVJU 18,000 32,000 Hermetically sealed swing type compressor 50/51 52/54 14 - 115 14 - 115 5 - 72 5 - 72 1/4 x2 1/4 x4 3/8 x2 3/8 x1, 1/2 x1, 5/8 x2 164 (82) 230 (82) 49.2 49.2 28 15/16 x 32 1/2 x 11 13/16 30 5/16 35 7/16 12 5/8 139 168 Nominal cooling capacity Btu/h 18,000 16,000 17,000 30,600 29,000 29,800 Nominal heating capacity Btu/h 22,000 22,000 22,000 32,000 30,400 31,200 Low heating capacity Btu/h 13,500 13,100 13,300 22,200 21,000 21,600
Non Ducted Indoor Unit** Ducted Indoor Unit Mixed Ducted and Non Ducted Indoor Unit Non Ducted Indoor Unit 4MXS32GVJU Ducted Indoor Unit Mixed Ducted and Non Ducted Indoor Unit * For capacity information, refer to the Engineering Data Book 2MXS18GVJU
A Daikin Multi-Split System can serve from two to four rooms using only one outdoor unit, and allows individual control of the air conditioning in each room. On top of the savings generated from the flexibility of Daikins Multi-Split systems, further cost reductions are achieved from the energy efficient benefits of Daikins Inverter Technology offering outstanding energy efficiency with SEER ratings up to 19.5. Select from Daikins extensive range of wall-mounted or ducted indoor fan coil units to cool or warm your space. The flat panel design of the wall-mounted units will complement interior decor, while the slim shape of the ducted units are barely noticeable when installed in a ceiling or soffit.
**2MXS18GVJU in Non Ducted Indoor Unit combination is Energy Star rated
www.daikinac.com
SkyAir Systems
Indoor Units - FAQ_PVJU and FTXS_HVJU Wall Mounted Units
Model Cooling Capacity (min. - nom. - max.) Heating Capacity (min. - nom. - max.) Moisture Removal Airflow-Dry (H/M/L/SL) Sound Pressure Level - Cooling (H/M/L) Sound Pressure Level - Heating (H/M/L) Piping connections Liquid (O.D.) Gas (O.D.) Condensate (O.D.) Btu/h Btu/h Pt/h cfm dB(A) dB(A) in. in. in. in. lbs. FAQ18PVJU FAQ24PVJU *-18,000 - 18,000 *-24,000 - 24,000 *- 20,000 - 20,000 *- 27,000 - 27,000 * * 500/*/400/* 635/*/470/* 43/*/* 47/*/* 43/*/* 47/*/* 3/8 3/8 5/8 5/8 11/16 11/16 11 3/8 x 41 3/8 x 9 31 31 FCQ18PVJU 18,000 20,000 * 790/670 42/* 42/* 3/8 5/8 11/16 84 FHQ18PVJU 18,000 20,000 * 790/670 45/* 45/* 3/8 5/8 11/16 90 RZQ18PVJU FAQ18PVJU FCQ18PVJU FHQ18PVJU Btu/h SEER HSPF W W dB(A) F F F A ft. ft. in. lbs. 18,000 13 7.7 * * 48/49 23-115 0-115 0 - 77 7.37 164 98 135 FCQ24PVJU 24,000 27,000 * 790/670 42/* 42/* 3/8 5/8 11/16 84 FHQ24PVJU 24,000 27,000 * 790/670 45/* 45/* 3/8 5/8 11/16 90 RZQ24PVJU FAQ24PVJU FCQ24PVJU FHQ24PVJU 24,000 Hermetically sealed swing type compressor 13 7.7 * * 49/51 23-115 0-115 0 - 77 10.57 164 98 30-5/16 x 35-7/16 x 12-5/8 135
FAQ18PVJU FAQ24PVJU
FTXS30HVJU FTXS36HVJU
Unit Dimensions (H x W x D) Weight Model Cooling Capacity (nom.) Heating Capacity (nom.) Moisture Removal Airflow-Dry (H/L) Sound Pressure Level - Cooling (H/L) Sound Pressure Level- Heating (H/L) Piping connections Dimensions (H x W x D) Weight (including panel) Liquid (O.D.) Gas (O.D.) Condensate (O.D.)
Indoor Units - FCQ_PVJU and FCQ_MVJU Ceiling Mounted 4-Way Cassette Units
Btu/h Btu/h Pt/h cfm dB(A) dB(A) in. in. in. in. lbs.
Btu/h Btu/h Pt/h cfm dB(A) dB(A) in. in. in. in. lbs.
Outdoor Units - RZQ_PVJU and RZQ_MVJU Heat Pump (Refer to table below for connection models)
36,000 42,000 Hermetically sealed scroll type compressor 13 13 7.7 7.7 * * * * 58/58 58/58 14-115 14-115 0-115 0-115
RZQ36MVJU RZQ42MVJU
0 - 77 0 - 77 22.5 23.3 230 230 164 164 52-15/16 x 35-7/16 x 12-5/8 310 310
Outdoor Units - RXS_HVJU Heat Pump For use with FTXS_HVJU Models
Btu/h SEER HSPF W W dB(A) F F F F A A ft. ft. in. lbs. RXS30HVJU RXS36HVJU FTXS30HVJU FTXS36HVJU 30,000 36,000 Hermetically sealed swing compressor 17 16.2 8.3 8.3 2,800** 4,300** 3,900** 4,200** 54/55 54/55 14 - 115 14 - 115 0 - 115 5 - 75 0 - 75 12.2** 17.1** 100 66 39 x 37 x 12-19/32 176.4 176.4 0 - 115 5 - 75 0 - 75 18.8** 18.4** 100 66
Operation Current - Cooling Operation Current - Heating Max. Piping Length Max. Height Difference Dimensions (H x W x D) Weight * Information not available at time of press ** These values are based on 230V
What is VRV?
VRV is an applied air conditioning system that distributes refrigerant to the fan coil units in the conditioned spaces, rather than water. The features of VRV
n Energy efficient n Many zones (individual control) n Centralized system (long piping) n T ight control (PID) n Large capacity (modular) n H igh level centralized control (including BACnet, LonWorks) n Quiet operation n Absolute comfort n Cold dry air (cooling) low sensible heat factor n Heating - benefit of R-410A and inverter technology
With these attributes, VRV is naturally most comparable to traditional chilled water systems.
Daikin Inverter AC
Non-inverter AC
n Air cooled condensing unit n 208-230V one phase power supply n Available in 3 and 4 Ton n Individual zone control n Can operate up to 6 or 8 fan
heat exchanger)
n A vailable up to 21 Ton in 7 combinations n 208-230V three phase power supply n U p to 32 indoor units can be connected
with a choice of 10 different styles and 46 models ranging from 0.6 to 4 Ton
n C onnect to a cooling tower (closed loop)
coil units
n Advanced zoning capabilities n Innovative space-saving design n Reliability n Outstanding warranties n AHRI Certified
operation
n Longest pipe lengths in product class (up
to 3,280 ft)
n 2 08-230V or 460V three phase power
condensing units
n C old climate capability delivering
supply
n A dvanced zoning capabilities
www.daikinac.com
0.6 Ton
0.75 Ton
1 Ton
1.5 Ton
2 Ton
FXSQ30MVJU 30,000 34,000 45/39 1 950/720 119 FXMQ30MVJU 30,000 34,000 45/41 2 690/565 99
2.5 Ton
3 Ton
FXSQ48MVJU 48,000 54,000 48/43 1 1,300/950 122 FXMQ48MVJU 48,000 54,000 48/45 2 1,270/1,020 144
4 Ton
FXDQ12MVJU 12,000 13,500 33/29 2 280/226 51 FXFQ12MVJU 12,000 13,500 31/28 2 460/350 55
FXDQ18MVJU 18,000 20,000 35/31 2 440/350 63 FXFQ18MVJU 18,000 20,000 33/28 2 570/390 55
FXDQ24MVJU 24,000 27,000 36/32 2 580/460 71 FXFQ24MVJU 24,000 27,000 34/29 2 670/490 55
11 3/8 x 31 1/4 x 9
FXAQ12MVJU 12,000 13,500 38/31 3 300/180 25 FXLQ12MVJU 12,000 13,500 36/33 4 280/210 66
23 5/8 x 44 7/8 x 8 3/4
FXAQ18MVJU 18,000 20,000 43/37 3 500/400 31 FXLQ18MVJU 18,000 20,000 40/35 4 490/380 80
11 3/8 x 41 3/8 x 9
FXAQ24MVJU 24,000 27,000 47/40 3 635/470 31 FXLQ24MVJU 24,000 27,000 41/36 4 560/420 80
Btu/h Btu/h dB(A) cfm lbs. in. Btu/h Btu/h dB(A) cfm lbs. in.
24 x 42 1/8 x 8 5/8
FXNQ12MVJU 12,000 13,500 36/33 4 280/210 51 FXHQ12MVJU 12,000 13,500 38/33 3 410/340 55
24 x 53 1/8 x 8 5/8
FXNQ24MVJU 24,000 27,000 41/36 4 560/420 59 FXHQ24MVJU 24,000 27,000 44/36 3 710/600 80 FXHQ36MVJU 36,000 40,000 46/41 3 830/670 90
Indoor Units - FXOQ_MVJU Vertical Air Handler Unit (FXOQ42MVJU Model Also Available)
The FXOQ + BEQ unit cannot be installed on the same system as that containing Indoor Units from another VRV indoor unit family
The use of a BEQ box is required when installing the FXOQ unit (208V / 1Ph / 60Hz)
FXOQ12MVJU 12,000 12,000 400 120 FXOQ18MVJU 18,000 18,000 600 120 44 x 15 x 22 BEQ18MVJLR1 FXOQ24MVJU 24,000 24,000 800 120 FXOQ30MVJU 30,000 30,000 1,000 140 48 x 18 1/2 x 22 BEQ30MVJLR1
BEQ12MVJLR1
BEQ24MVJLR1
FXOQ36MVJU FXOQ48MVJU 36,000 48,000 40,000 54,000 1,200 1,600 210 210 49 x 20 x 26 BEQ36MVJLR1 BEQ48MVJLR1
Notes: 1 at 5 ft below bottom suction grill of unit 2 at 5 ft below the unit 3 at 3.3 ft below and from the unit 4 measured at 5 ft away, 5 ft high
www.daikinac.com
6 Ton
RXYQ72PTJU 72,000 5.4 81,000 6.0 (20,472) 23 - 110 0 - 77 / -4 - 60 208-230/3/60 58 6,530 295 540 620 3,280 560
8 Ton
RXYQ96PTJU 96,000 8.6 108,000 8.7 (29,684) 23 - 110 0 - 77 / -4 - 60 208-230/3/60 58 6,530
10 Ton
RXYQ120PTJU 120,000 10.9 135,000 11.4 (38,897) 23 - 110 0 - 77 / -4 - 60 208-230/3/60 60 7,060 295 540 620 3,280 560
12 Ton
RXYQ144PTJU 144,000 13.2 162,000 13.4 (45,721) 23 - 110 0 - 77 / -4 - 60 208-230/3/60 61 8,300 295 540 620 3,280 747
14 Ton
RXYQ168PTJU RXYQ96PTJU + RXYQ72PTJU 168,000 14.0 189,000 14.7 (50,156) 23 - 110 0 - 77 / -4 - 60 208-230/3/60 61 6,530 + 6,530 295 540 620 3,280 560 + 560
16 Ton
RXYQ192PTJU RXYQ120PTJU + RXYQ72PTJU 192,000 16.3 216,000 17.4 (59,369) 23 - 110 0 - 77 / -4 - 60 208-230/3/60 62 7,060 + 6,530
18 Ton
RXYQ216PTJU RXYQ120PTJU + RXYQ96PTJU 216,000 19.5 243,000 20.1 (68,581) 23 - 110 0 - 77 / -4 - 60 208-230/3/60 62 7,060 + 6,530
20 Ton
RXYQ240PTJU 2x RXYQ120PTJU 240,000 21.8 270,000 22.8 (77,794) 23 - 110 0 - 77 / -4 - 60 208-230/3/60 63 7,060 + 7,060 295 540 620 3,280 560 + 560
Airflow
Actual Pipe Length Equivalent Pipe Length Total Pipe Length Weight Dimensions (H x W x D) Model
295 295 540 540 620 620 3,280 3,280 560 + 560 560 + 560 66 1/8 x (36 5/8 x 2) x 30 1/8
6 Ton
REYQ72PTJU
8 Ton
REYQ96PTJU
10 Ton
REYQ120PTJU
12 Ton
REYQ144PTJU
14 Ton
16 Ton
18 Ton
20 Ton
Airflow
Actual Pipe Length Equivalent Pipe Length Total Pipe Length Weight Dimensions (H x W x D)
REYQ168PTJU REYQ192PTJU REYQ216PTJU REYQ240PTJU REMQ96PTJU + REMQ120PTJU + REMQ120PTJU + 2x REMQ120PTJU REMQ72PTJU REMQ72PTJU REMQ96PTJU Btu/h 72,000 96,000 120,000 144,000 168,000 192,000 216,000 240,000 kW 5.3 8.4 10.9 13.2 14.0 16.3 19.5 21.8 Btu/h 81,000 108,000 135,000 162,000 189,000 216,000 243,000 270,000 kW (Btu/h) 6.05 (20,643) 8.95 (30,537) 11.2 (38,214) 13.4 (45,721) 14.7 (50,156) 17.4 (59,369) 20.1 (68,581) 22.8 (77,794) F 23 - 110 23 - 110 23 - 110 23 - 110 23 - 110 23 - 110 23 - 110 23 - 110 F 0 - 77 / -4 - 60 0 - 77 / -4 - 60 0 - 77 / -4 - 60 0 - 77 / -4 - 60 0 - 77 / -4 - 60 0 - 77 / -4 - 60 0 - 77 / -4 - 60 0 - 77 / -4 - 60 V/Ph/Hz 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 dB(A) 58 58 60 62 61 62 62 63 cfm 6,700 6,700 7,410 8,300 6,530 + 6,530 7,060 + 6,530 7,060 + 6,530 7,060 + 7,060 ft. 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) ft. 295 295 295 295 295 295 295 295 ft. 540 540 540 540 540 540 540 540 ft. 620 620 620 620 620 620 620 620 ft. 3,280 3,280 3,280 3,280 3,280 3,280 3,280 3,280 730 730 730 747 560 + 450 560 + 450 560 + 560 560 + 560 lbs. in. 66 1/8 x 51 3/16 x 30 1/8 66 1/8 x (36 5/8 x 2) x 30 1/8
6 Ton
RXYQ72PYDN
8 Ton
RXYQ96PYDN
10 Ton
RXYQ120PYDN
12 Ton
RXYQ144PYDN
14 Ton
16 Ton
18 Ton
20 Ton
Airflow
Actual Pipe Length Equivalent Pipe Length Total Pipe Length Weight Dimensions (H x W x D) Model
RXYQ168PYDN RXYQ192PYDN RXYQ216PYDN RXYQ240PYDN RXYQ72PYDN + RXYQ72PYDN + RXYQ96PYDN + 2x RXYQ72PYDN 2x RXYQ120PYDN RXYQ96PYDN RXYQ120PYDN RXYQ120PYDN Btu/h 72,000 96,000 120,000 144,000 168,000 192,000 216,000 240,000 kW 5.6 9.1 11.8 11.2 14.7 17.4 20.9 23.6 Btu/h 81,000 108,000 135,000 162,000 189,000 216,000 243,000 270,000 kW (Btu/h) 6.6 (22,519) 9.6 (32,755) 12.3 (41,968) 13.2 (45,038) 16.2 (55,274) 18.9 (64,487) 21.9 (74,723) 24.6 (83,935) F 23 - 110 23 - 110 23 - 110 23 - 110 23 - 110 23 - 110 23 - 110 23 - 110 F 0 - 77 / -4 - 60 0 - 77 / -4 - 60 0 - 77 / -4 - 60 0 - 77 / -4 - 60 0 - 77 / -4 - 60 0 - 77 / -4 - 60 0 - 77 / -4 - 60 0 - 77 / -4 - 60 V/Ph/Hz 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 dB(A) 58 58 60 61 61 62 62 63 cfm 6,350 6,350 7,060 6,530 + 6,530 6,530 + 6,530 7,060 + 6,530 7,060 + 6,530 7,060 + 7,060 ft. 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) ft. 295 295 295 295 295 295 295 295 ft. 540 540 540 540 540 540 540 540 ft. 620 620 620 620 620 620 620 620 ft. 3,280 3,280 3,280 3,280 3,280 3,280 3,280 3,280 lbs. 573 573 573 573 + 573 573 + 573 573 + 573 573 + 573 573 + 573 in. 66 1/8 x 36 5/8 x 30 1/8 66 1/8 x (36 5/8 x 2) x 30 1/8
6 Ton
REYQ72PYDN
8 Ton
REYQ96PYDN
10 Ton
REYQ120PYDN
12 Ton
REYQ144PYDN
14 Ton
16 Ton
18 Ton
20 Ton
REYQ168PYDN REYQ192PYDN REYQ216PYDN REYQ240PYDN REMQ72PYDN + REMQ72PYDN + REMQ96PYDN + Combination 2x REMQ72PYDN 2x REMQ120PYDN REMQ96PYDN REMQ120PYDN REMQ120PYDN Cooling Capacity Btu/h 72,000 96,000 120,000 144,000 168,000 192,000 216,000 240,000 Cooling Input Power kW 5.5 8.8 11.8 11.2 14.7 17.4 20.9 23.6 Heating Capacity Btu/h 81,000 108,000 135,000 162,000 189,000 216,000 243,000 270,000 Heating Input Power kW (Btu/h) 6.4 (21,837) 9.6 (32,755) 12.3 (41,968) 13.2 (45,038) 16.2 (55,274) 18.9 (64,487) 21.9 (74,723) 24.6 (83,935) Operating Range - Cooling (DB) F 23 - 110 23 - 110 23 - 110 23 - 110 23 - 110 23 - 110 23 - 110 23 - 110 Operating Range - Heating (DB/WB) F 0 - 77 / -4 - 60 0 - 77 / -4 - 60 0 - 77 / -4 - 60 0 - 77 / -4 - 60 0 - 77 / -4 - 60 0 - 77 / -4 - 60 0 - 77 / -4 - 60 0 - 77 / -4 - 60 Power V/Ph/Hz 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 Sound Pressure Level @3ft dB(A) 58 58 60 60 61 62 62 63 Airflow cfm 6,700 6,700 7,410 6,530 + 6,530 6,530 + 6,530 7,060 + 6,530 7,060 + 6,530 7,060 + 7,060 Vertical Pipe Length - above ft. 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) Vertical Pipe Length - below ft. 295 295 295 295 295 295 295 295 Actual Pipe Length ft. 540 540 540 540 540 540 540 540 Equivalent Pipe Length ft. 620 620 620 620 620 620 620 620 Total Pipe Length ft. 3280 3280 3280 3280 3280 3280 3280 3280 Weight lbs. 732 732 732 463 + 463 573 + 463 573 + 463 573 + 573 573 + 573 Dimensions (H x W x D) in. 66 1/8 x 51 3/16 x 30 1/8 66 1/8 x (36 5/8 x 2) x 30 1/8 BSVQ36PVJU BSVQ60PVJU 1 phase 208-230V 60Hz 8 1/8 x 15 1/4 x 12 13/16 26 3/8 (braze) 3/8 (braze) 5/8 (braze) 5/8 (braze) 3/8 (braze) 3/8 (braze) 5/8 (braze) 5/8 (braze) 1/2 (braze) 1/2 (braze)
Indoor Unit Piping Connections Outdoor Suction Gas in. Unit HP/LP Gas in.
For all equipment installation and application limitations please refer to the specific Engineering Data Books.
www.daikinac.com
Certified Performance
Following developments with the U.S. Department Of Energy (DOE), the VRV-S systems are performance certified to ARI Standard 210/240 with the following performance values:
Outdoor Unit Indoor Units Combination Non-Ducted Indoor Units RXYMQ36MVJU Ducted Indoor Units Mixed Ducted and Non-Ducted Indoor Units Non-Ducted Indoor Units RXYMQ48MVJU Ducted Indoor Units Mixed Ducted and Non-Ducted Indoor Units ARI Reference Number 3024378 3024380 3024382 3024379 3024381 3024383
Cooling Nominal EER Capacity (Btu/h) 95 F 38,000 36,000 37,000 47,500 48,000 47,500 11.20 9.60 10.40 9.40 9.00 9.20 Nominal Capacity (Btu/h) 42,000 40,000 41,000 52,500 54,000 53,000
Low Heating 17 F Capacity (Btu/h) 29,600 31,200 30,400 33,600 36,400 35,000
Estimated National Average Annual Operating Cost Cool $229 $238 $233 $294 $315 $303 Heat $338 $618 $520 $510 $614 $606
S S
S S S
www.daikinac.com
5 Ton
RWEYQ60MTJU 60,000 3.41 67,500 3.2 (10,918) 208-230/3/60 50
6 Ton
RWEYQ72MTJU 72,000 4.2 81,000 4.0 (13,648) 208-230/3/60 50
7 Ton
RWEYQ84MTJU 84,000 5.6 94,500 5.4 (18,425) 208-230/3/60 51
12 Ton
RWEYQ144MTJU 2x RWEYQ72MTJU 144,000 8.4 162,000 8.0 (27,296) 208-230/3/60 53
14 Ton
RWEYQ168MTJU 2x RWEYQ84MTJU 168,000 11.2 189,000 10.8 (36,850) 208-230/3/60 54
18 Ton
RWEYQ216MTJU 3x RWEYQ72MTJU 216,000 12.6 243,000 12.0 (40,944) 208-230/3/60 56
21 Ton
RWEYQ252MTJU 3x RWEYQ84MTJU 252,000 16.8 283,500 16.2 (55,274) 208-230/3/60 57
Model Name Combination Cooling Capacity Cooling Input Power Heating Capacity Heating Input Power Power Supply Sound Pressure Level @3ft System Configuration Liquid Pipe (Main Line) Suction Gas Pipe (Main Line) Discharge Gas Pipe (Main Line) Vertical Pipe Length (If unit below FCU) Actual Pipe Length (Equivalent Length) Total Pipe Length BPHE Inlet Pipe (Female Thread) BPHE Outlet Pipe (Female Thread) Drain Pipe (Female Thread) Max. System Water Pressure (BPHE) Inlet Water Temperature Range Inlet Water Flow Range Weight Dimensions (H x W x D)
Refrigerant Side
Btu/h kW Btu/h kW (Btu/h) V/Ph/Hz dB(A) in. in. in. ft. ft. ft. in. in. in. psi F lbs. in.
Heat Pump Heat Recovery Heat Pump Heat Recovery Heat Pump Heat Recovery Heat Pump Heat Recovery Heat Pump Heat Recovery Heat Pump Heat Recovery Heat Pump Heat Recovery
Unit
3/8 3/8 N/A 3/4 3/4 5/8 164 (130) 390 (459) 980 1-1/4FPT 1-1/4FPT 1/2FPS 285 (50) 59 - 113 (13.2) 39.5 gpm 330
3/8 3/8 N/A 3/4 3/4 5/8 164 (130) 390 (459) 980 1-1/4FPT 1-1/4FPT 1/2FPS 285 (50) 59 - 113 (13.2) 39.5 gpm 330 39 3/8 x 30 3/4 x 21 11/16
3/8 3/8 N/A 7/8 7/8 3/4 164 (130) 390 (459) 980 1-1/4FPT 1-1/4FPT 1/2FPS 285 (50) 59 - 113 (13.2) 39.5 gpm 330
1/2 1/2 5/8 5/8 N/A 1-1/8 N/A 1-1/8 1-1/8 7/8 1-1/8 7/8 164 (130) 164 (130) 390 (459) 390 (459) 980 980 (1-1/4FPT)x2 (1-1/4FPT)x2 (1-1/4FPT)x2 (1-1/4FPT)x2 (1/2FPS)x2 (1/2FPS)x2 285 285 (50) 59 - 113 (50) 59 - 113 (13.2) 39.5 gpm (13.2) 39.5 gpm 330x2 330x2 39 3/8 x (30 3/4 x 2) x 21 11/16
5/8 5/8 3/4 3/4 N/A 1-3/8 N/A 1-3/8 1-3/8 1-1/8 1-3/8 1-1/8 164 (130) 164 (130) 390 (459) 390 (459) 980 980 (1-1/4FPT)x3 (1-1/4FPT)x3 (1-1/4FPT)x3 (1-1/4FPT)x3 (1/2FPS)x3 (1/2FPS)x3 285 285 (50) 59 - 113 (50) 59 - 113 (13.2) 39.5 gpm (13.2) 39.5 gpm 330x3 330x3 39 3/8 x (30 3/4 x 3) x 21 11/16
Water Side
Outdoor Unit
With the addition of the newly developed VRV-WII geothermal control logic, the operation range can now be extended to as low as 24.8 F (-4 C) entering water temperature (EWT) in heating. This is achieved with the addition of a field installed replacement condenser control board.
www.daikinac.com
Multi-Zone Controllers
Unified On/Off R/C DSC301C71 Centralized R/C DSC302C71
Model
1 Group/16 Units
16 Groups
64 Groups
128 Groups
Operation
Temperature Setting Set-Point Range Permit/Prohibit Selection Fan Speed Airflow Direction Status Malfunction Flashing Malfunction Content 60-90F 60-90F 60-90F 60-90F
Monitoring Scheduling
Filter Sign Operation Mode Temperature Setting Permit/Prohibit Selection Fan Speed Airflow Direction Weekly Timed Starts/Stops Per Day No. of Weekly Schedules Auto ON/OFF Timer Error History Field Setting Mode Group Setting 7-Day Time Clock
5-Temperature Setpoints Per Day
2 8
Data
Control Management
Minimum Night Setting Maximum Day Setting Night Set-Back Function Home Leave Function Auto Restart
n 1 ,024 groups (2,048 groups) connectable n M anagement of AC units, facilities, and ancillary equipment n O peration on 1 master PC and 1 sub PC n Remote monitoring via the web
n 64 groups (128 indoor units) connectable, another 64 groups (128 indoor units) connectable with DIII-Net adaptor option n Management of AC units, facilities, and ancillary equipment n Touch screen display n Built-in Ethernet port, Web enabled (optional)
www.daikinac.com
Energy Efficiency and lower operating costs result from being able to control each zone or room individually, allowing you to adjust the level of air conditioning based on its use. Innovative Space Saving Design has been incorporated into every aspect of the system, so you can utilize each area to its fullest. Reliability is assured throughout, with high specification, intelligent design and functions. Enjoy the comfort of having one of the Best Warranties in the business.
Organization: DAIKIN INDUSTRIES, LTD. AIR CONDITIONING MANUFACTURING DIVISION Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF COMMERCIAL AIR CONDITIONING, HEATING, COOLING, REFRIGERATING EQUIPMENT, COMMERCIAL HEATING EQUIPMENT, RESIDENTIAL AIR CONDITIONING EQUIPMENT, HEAT RECLAIM VENTILATION, AIR CLEANING EQUIPMENT, MARINE TYPE CONTAINER REFRIGERATION UNITS, COMPRESSORS AND VALVES.
Organization: DAIKIN INDUSTRIES (THAILAND) LTD. Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF AIR CONDITIONERS AND THE COMPONENTS INCLUDING COMPRESSORS USED FOR THEM.
All of the Daikin Group's business facilities and subsidiaries in Japan are certified under the ISO 14001 International standard for environmental management.
2008 Daikin Industries, Limited. Daikin , Daikin AC Absolute Comfort, and its design, VRV and REFNET are trademarks pending or registered trademarks of Daikin Industries, Limited. All rights reserved. LonWorks and LON are registered trademarks of Echelon Corporation. BACnet is a Data Communication Protocol for Building Automation and Control Networks, developed under the auspices of the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).
Dealer Information
For all equipment installation & application limitations please refer to the specific Engineering Data Books.
Daikins products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this brochure without notice and without incurring any obligations.