PHASE DYNAMICS
TECHNOLOGY THAT PRODUCES PRECISION MEASUREMENTS
1
Sales_Oil_0204
Product History
Developed with ARCO (Atlantic Richfield Company) Now BP 1985 Through 1990 for North Slope of Alaska Required Low Range for Pipeline Full Range for Wells Research Generated a New Patented Approach for Measurement Reduced System Complexity Improved Sensitivity More Than 2,500 Installed World Wide
2
Sales_Oil_0105
System Cable
3
Sales_Oil_0105
Stand-Alone Analyzer
Sales_Oil_0105
Sales_Oil_0105
6
Sales_Oil_0204
Large Difference in Parameters for Measurement RF Permittivity 2.5 for Oil, 80 for Water - Easy to See the Water A Measure of the Polar Moment of the Molecule
Full Cross Sectional Area Measurement is Made Eliminates Paraffin Build Up Problems Reduces Effect of Gas Bubbles
Coaxial Line Is Used for: Rugged Mechanical Configuration The Best Defined Microwave Configuration
7
Sales_Oil_0105
Patented Technique - Oscillator Load Pull A Microwave Phenomenon That Was Never Used Before Phase Dynamics Implementation Provides 100-1000 Times Sensitivity Improvement Over Other RF/Microwave Methods Makes the System Electronics Simple
Coaxial Measurement Section Configuration Provides a Stable, Well Defined RF/Microwave Platform Better Than Open Waveguide or Cavity Types
Frequency of Operation Depends on Range of Water and Pipe Size - Typically 100 to 500 MHz
8
Sales_Oil_0105
Measurement Section
Frequency of Operation 150 to 500 MHz Depending on Diameter & Range
RF Oscillator
Wave Propagation
Higher Water Slows Velocity of Wave (i.e. Phase) & Oscillator Changes Frequency Less Water
More Water
Emulsion Size, Pipe Diameters & Wavelength Are Consistent With Measurement Accuracy & Need for Full Cross Section Area Measurement
Sales_Oil_0105
10
Analyzer Systems
X X
X X
X X
X X
Water Tank
Gas
Three Phase Separator Level Control
To Gas Pipeline
Oil
Water
LACT
To Pipeline
Production Separator
Sales_Oil_0105
11
0-4%, 0-10%, and 0-20% Ranges Available, 1" to 4" Sizes Ultra High Stability and Reproducibility Due to Sensitivity Improvement by the Technology Ambient Compensation Obtained by Military Techniques
Net Oil Capability Feed a Flow Meter Input Into Unit Obtain Total Barrels of Oil and Water Over Time
Paraffin and Coating Buildup has Minimal Effects Very Low Pressure Drop
Sales_Oil_0105
12
13
Sales_Oil_0204
C5H12
H +e
H +e
n Pentane r = 2.1
Water r = 80
Oil Density Increased r (Polar Moment) Increased Looks Like More Water Increased Density Hydrocarbon
Sales_Oil_0105
14
Sales_Oil_0105
15
Sales_Oil_0105
16
Sales_Oil_0105
17
18
Sales_Oil_0204
Oi l
Center Rod
Like a Capacitor
19
Salinity Has An Effect In The Water Phase ONLY for the Phase Dynamics Analyzer Salt Affects Electrical Conductivity - Establishes Where 100% Water Exists Correction Is Required ONLY for this Emulsion Phase Which is Typically Greater Than 65% Water Content
Higher Frequency (< 1.5 GHz) Competitive Microwave Equipment Must Compensate for Salinity In The OIL EMULSION PHASE: When Emulsion Size Is Approaching 1/8 of a Wavelength Voltage Changes Due to the Short Wavelength Across The Emulsion Bubble - Therefore There Is A Current Through The Emulsion Creating a Measurement Issue
20
Sales_Oil_0105
0 - 100% Water in Oil Measurement - Gives the Emulsion Phase Oil or Water Phase Emulsion Correction For Salinity Effects Salinity is Corrected to Achieve the Smallest Uncertainty Automatic Correction Provides Unacceptable Error Correction is Only for the Water Emulsion Phase - Typically Greater than 65% Water Cut Some Competitive Systems Require Compensation in the Oil Phase Insensitive to Flow Rates Viscosity, Temperature & Water Cut Determine Velocity Required Typical Recommendation - Rates Greater than 2 ft/sec Issue is Homogeneity of the Liquids - Not Flow Rate
Sales_Oil_0105
21
RF Switc h
Power Sensor
Output
Water Osc Water Oscillator More Sensitive Oil Oscillator Less Sensitive to obtain 0-80% Two Unknowns - Water & Emulsion Phase Two Variables - Frequency & Power
Sales_Oil_0105
22
23
Sales_Oil_0204
24
Calibration Methodology
Factory Calibration is Complete Analyzer is Ready to Use When Installed Temperature Curves Complete Water Cut Slope vs Frequency Complete
Low Range Analyzer Offset for Density (Cal Factor) Full Range Analyzer Density Offset (Oil_Adjust) Salinity - Affects Water Continuous Emulsions Only
Sales_Oil_0105
25
26
( 0.31 ,0.22 ) Difference = .09% Bad Sample Or Is This Within Expected Statistical Deviation?
0.4 0.5
Sales_Oil_0105
27
Sales_Oil_0105
28
Sales_Oil_0105
29
Conductivity / Capacitance Density Microwave Absorption of Energy (2-3 GHz) Wave Resonance (400 MHz-3 GHz) PHASE DYNAMICS (100-300 MHz) Infrared Radiation
Sales_Oil_0105
30
An Example of Typical Retractable Systems Packing Got Stuck on Shaft? Got Stuck Because the Valve Was Closed with the Shaft Present? When Do You Need To Retract? Needs Cleaning? Doesnt Work?
Phase Dynamics Does Not Need to Be Cleaned & Seldom, if Ever, Needs to Be Taken Out of the Line
Sales_Oil_0105
32