Hoistway Section
1.
If the pit depth is more than the maximum, please fill back to the maximum depth.
2.
If the sum of travel and overhead is less than 11100 mm, please consult HITACHI.
3.
If the ceiling design is EX type, minimum overhead shall be increased by 250 mm.
4.
5.
Maximum travel: 60 m.
6.
Load
(kg)
Persons
Speed
(m/min)
Model
Door opening
width (mm)
450
60
UAG-450-CO60
800
60
UAG-550-CO60
90
UAG-550-CO90
105
UAG-550-CO105
60
UAG-600-CO60
90
UAG-600-CO90
105
UAG-600-CO105
60
UAG-700-CO60
90
UAG-700-CO90
105
UAG-700-CO105
60
UAG-750-CO60
90
UAG-750-CO90
105
UAG-750-CO105
60
UAG-900-CO60
90
UAG-900-CO90
105
UAG-900-CO105
60
UAG-1000-CO60
90
UAG-1000-CO90
105
UAG-1000-CO105
2
3
550
4
5
6
7
600
(615)
700
10
8
9
10
11
12
750
11
13
14
15
900
13
16
17
18
19
1000
15
800
800
800
900
900
900
Car internal
AxB
(mm)
1400 x
850
1400 x 1030
1400 x 1150
1400 x 1250
1350 x 1400
1600 x 1400
1600 x 1550
Hoistway
XxY
(mm)
Minimum
overhead (mm)
2000
1570
3900
2000
1740
3900
2000
1790
2000
1860
2000
1910
2000
1960
2000
2010
2050
2110
2050
2160
2200
2110
2200
2160
2200
2260
2200
2310
4000
4050
3900
4000
4050
3900
4000
4050
3900
4000
4050
3900
4000
4050
3900
4000
4050
Motor
capacity (kW)
Minimum
Maximum*1
1650
1650
2.8
1650
3.4
1400
1450
1400
1450
1400
1450
1400
1450
1400
1450
1400
1450
1800
5.1
1850
5.9
1650
3.7
1800
5.6
1850
6.5
1650
4.4
1800
6.5
1850
7.6
1650
4.6
1800
6.9
1850
8.1
1650
5.6
1800
8.3
1850
9.7
1650
6.0
1800
9.0
1850
10.5
Page 1/1
Doc No. UAG-1
Data is last updated as of 15 Sep 2007