Professional Documents
Culture Documents
Contact details
NSW/ACT VIC EMAIL
3/165 Rookwood Road
Yagoona NSW 2199
Axxess Corporate Park
120/45 Gilby Road
sales@incitefire.com.au
accounts@incitefire.com.au 1300 INCITE
Tel: 1300 INCITE Mount Waverley VIC info@incitefire.com.au
Fax: 02 9707 1900 Tel: 1300 INCITE
Incite Fire Pty Ltd is a fully independent fire alarm systems product wholesaler, Sydney & Melbourne based, H ochiki D etector & B ase C ompatibility C hart
established in 1999.
YBF-RL/2NBF
Analogue
Previous
Our Objective
Bases
“Quality fire detection and warning equipment,
independently supplied & supported”
YBN-R/2NA
YBO-R/SCI
Analogue
Bases
New
Conventional Fire Detection
We stock the complete range of current & past model Hochiki detectors, as well as a
selection of conventional panels which can be customised to suit your requirements.
Addressable
YBF-RL/3JM
AMU-MBM
AMU-B2M
Previous
Incite Fire is the NSW & ACT distributor of the FireNet analogue panel. We also stock the
Bases
complete range of Hochiki addressable detectors & field modules.
VESDA
Incite Fire is an authorised distributor for the complete range of VESDA aspirated detectors
YCA-RL/3H2M
YBF-RL/4AHAM YCA-RL/5H2M
as well as pipework & fittings. Spare parts are available & we can also arrange for
Addressable
the repair of all current model detectors.
Bases
New
Warning Systems
A range of OWS and accessories to suit your requirements, as well as EWIS panels
configurable to suit any site specifications.
Conventional Conventional
YBC-R/3A
Ancillary Equipment
Previous
Bases
A comprehensive range of ancillary devices including KAC manual call points, a selection
of speakers, sounders & strobes. We also stock a range of magnetic door retainers to suit
many different applications including the new brass & chrome finish door holders for a
more prestigious application.
YBO-R/4A
Special Applications
Bases
New
A selection of detection equipment for special applications including flame detectors,
firewire, VESDA. Also available is intrinsically safe equipment & detectors suitable
for marine applications.
Miscellaneous
SIH-AM – Ionization
AIE-AS – Ionization
ATG-AS – Thermal
AIA-E – Ionization
• Hochiki - Detectors Analogue & Conventional
ATA-E –Thermal
• VESDA - Range of Aspirated Detectors
• Simplex - Evacuation & Warning Systems
For further information
Call: 1300 INCITE (462483)
Or visit us at: www.incitefire.com.au
www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
CONTENTS
CONVENTIONAL
Panels 4
Detectors (current models) 5
Detectors (previous models) 7
ANALOGUE
Panels 8
Detectors (GTP protocol) 10
Handheld Programmer 13
Mimic PANELS 13
Field Devices (GTP protocol) 14
Short Circuit Isolators 15
Detectors & Devices (HRE protocol) 16
VESDA
Detectors 18
Remote Units 20
19” Racks 20
Filters 21
Software & Accessories 21
Spare Parts 22
Pipe & Fittings 24
WARNING SYSTEMS
EWIS & OWS 26
Tone Generators & Amplifiers 26
OWS Accessories 27
Speakers, Horns & Strobes 28
Strobe Sets, WIP & MCP 30
ANCILLARIES
Manual Call Points 32
Sounders & Strobes 33
Speakers & Horns 34
Strobe Sets & WIP 36
Magnetic Door Holders 37
Remote Indicators 38
Batteries 38
Power Supplies 39
Signs 39
Test Equipment 39
SPECIAL APPLICATIONS
Special Application Detectors 40
Intrinsically Safe detectors 41
Marine detectors 41
MISCELLANEOUS
Tools, Aerosols, Fixings, Enclosures 42
Components, Interface Leads & Cable 43
DCP-002 – Door Control / Local Alarm Panel SLV-AS - Hochiki photo optical smoke detector
The Incite DCP-002 is a solution for sliding fire doors and local alarm requirements. • Flat response smoke chamber • New chamber design to reduce nuisance alarms
• Dual LED’s for 360° viewing • Rated voltage: 24V DC (working voltage 15-30V DC)
• Self contained and simple to operate • Individual AZF alarm test, fault test, isolate & reset buttons
• Low profile, only 48mm (with base) • Only 100mm diameter
• 2 fully monitored AZF inputs • Individual AZF alarm, fault & isolate indicators
• Nominal sensitivity (S)=8.0% Obs/m • Low standby current 35.0μA nominal
• Accepts AS1670 detectors • Auxiliary output to interface to other equipment • Compatible base YBO-R/4A • SSL listing afp:1649
• Door holder output • Pre warning for door closers on mains failure
• Warning strobe output • Timer for door holder release operation DCD-A - Hochiki type ‘A’ thermal detector
• Bell output monitored • Internal sounder with isolate switch • Electronic linear heat detection • Combination rate of rise & fixed temperature
• Battery backed • Dual LED’s for 360° viewing • Rated voltage: 24V DC (working voltage 15-30V DC)
• Low profile, only 48mm (with base) • Only 100mm diameter
Conventional Detectors
• Alarming temperature 63° • Low standby current 35.0μA nominal
Conventional PANELS
Conventional Panels • Dual LED’s for 360° viewing • Rated voltage: 24V DC (working voltage 15-30V DC)
• Low profile, only 48mm (with base) • Only 100mm diameter
• Alarming temperature 63° • Low standby current 35.0μA nominal
• Compatible base YBO-R/4A • SSL listing afp:1120
04 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
05
C onventional C urrent M odel
P anels D etectors
DCP-002 – Door Control / Local Alarm Panel SLV-AS - Hochiki photo optical smoke detector
The Incite DCP-002 is a solution for sliding fire doors and local alarm requirements. • Flat response smoke chamber • New chamber design to reduce nuisance alarms
• Dual LED’s for 360° viewing • Rated voltage: 24V DC (working voltage 15-30V DC)
• Self contained and simple to operate • Individual AZF alarm test, fault test, isolate & reset buttons
• Low profile, only 48mm (with base) • Only 100mm diameter
• 2 fully monitored AZF inputs • Individual AZF alarm, fault & isolate indicators
• Nominal sensitivity (S)=8.0% Obs/m • Low standby current 35.0μA nominal
• Accepts AS1670 detectors • Auxiliary output to interface to other equipment • Compatible base YBO-R/4A • SSL listing afp:1649
• Door holder output • Pre warning for door closers on mains failure
• Warning strobe output • Timer for door holder release operation DCD-A - Hochiki type ‘A’ thermal detector
• Bell output monitored • Internal sounder with isolate switch • Electronic linear heat detection • Combination rate of rise & fixed temperature
• Battery backed • Dual LED’s for 360° viewing • Rated voltage: 24V DC (working voltage 15-30V DC)
• Low profile, only 48mm (with base) • Only 100mm diameter
Conventional Detectors
• Alarming temperature 63° • Low standby current 35.0μA nominal
Conventional PANELS
Conventional Panels • Dual LED’s for 360° viewing • Rated voltage: 24V DC (working voltage 15-30V DC)
• Low profile, only 48mm (with base) • Only 100mm diameter
• Alarming temperature 63° • Low standby current 35.0μA nominal
• Compatible base YBO-R/4A • SSL listing afp:1120
04 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
05
C urrent M odel P revious M odel
D etectors D etectors
SIJ-ASN – Hochiki ionisation smoke detector SLK-AS – Hochiki photo optical smoke detector (previous model)
• Stable operation under extreme conditions • Resistant to strong vibrations & voltage fluctuation • Low standby current 35.0μA nominal • Rated voltage: 24V DC (working voltage 15-30V DC)
• Low profile, only 48mm (with base) • Reliable under conditions such as high humidity • Compatible base YBF-RL/4AH4M or YBC-R/3A • SSL listing afp:600
• Only 100mm diameter • Rated voltage: 24V DC (working voltage 15-30V DC)
• Nominal sensitivity – 0.4 MIC X • Compatible base YBO-R/4A
DCC-A - Hochiki type ‘A’ thermal detector (previous model)
• Low standby current 25.0μA nominal • SSL listing afp:1117
• Low standby current 30.0μA nominal • Rated voltage: 24V DC (working voltage 15-30V DC)
• SSL listing afp:658 • Compatible base YBF-RL/4AH4M or YBC-R/3A
VANGUARD – Vandal proof steel cage for Hochiki detectors
DH-98-ASC - Hochiki conventional duct probe DFE-60B - Hochiki type ‘B’ thermal detector (previous model)
conventional Detectors
Conventional Detectors
• Rugged steel back box with clear cover • Compact design, only W185mm x H230mm x D50mm • Low standby current 30.0μA nominal • Rated voltage: 60V DC (working voltage 0-60V DC)
• Pre mounted detector base (YBO-R/4A) • Plug in photo optical or ionisation detector • SSL listing afp:660 • Compatible base YBF-RL/4AH4M or YBC-R/3A
• No screens or filter to clean • Complete with 1m aluminium sampling tubes
• SSL listing afp:1569 DCC-C - Hochiki type ‘C’ thermal detector (previous model)
• Low standby current 35.0μA nominal • Rated voltage: 24V DC (working voltage 15-30V DC)
SPC-AS – Hochiki projected beam detector • SSL listing afp:659 • Compatible base YBF-RL/4AH4M or YBC-R/3A
• Beam length of 5m – 100m • Compact design, only W86mm x H145mm x D100mm
• Microcomputer analysis of beam data • Automatic compensation for contamination of optics DFE-90D - Hochiki type ‘D’ thermal detector (previous model)
• Low standby current 250.0μA nominal • Ideal for large open spaces eg: warehouse & theatres
• Low standby current 30.0μA nominal • Rated voltage: 60V DC (working voltage 0-60V DC)
• Sensitivity setting of 35% to 50% / span • Rated voltage: 24V DC (working voltage 15-33V DC)
• SSL listing afp:663 • Compatible base YBF-RL/4AH4M or YBC-R/3A
• SSL listing afp:2186
HF-24AMK1 – Hochiki ultraviolet flame detector SIH-AS – Hochiki ionisation smoke detector (previous model)
• Detects flames by ultraviolet radiation • 120º detection angle • Low standby current 25.0μA nominal • Rated voltage: 24V DC (working voltage 15-30V DC)
• Low profile, only 70mm (with base) • Only 100mm diameter • Compatible base YBF-RL/4AH4M or YBC-R/3A • SSL listing afp:601
• Low standby current 200.0μA nominal • Rated voltage: 24V DC (working voltage 15-30V DC)
• SSL listing afp:57 • Compatible base YBO-R/3A or YBF-RL/4AH4M YBC-R/3A – Hochiki plain base (previous model)
• Compatible with (previous model detectors)
TYPE E PROBE – Type E thermal probe ~ SLK-A – Conventional photo optical ~ SIH-AS – Conventional ionisation
• Seamless machined AISI 316 stainless steel • Corrosion and shock resistant ~ DCC-A – Conventional A type thermal ~ DFE-60B – Conventional B type thermal
• Gold plated contacts • Factory set between 60°C to 240°C ~ DCC-C – Conventional C type thermal ~ DFE-90D – Conventional D type thermal
• IP67 rating • Operating current 0.5A maximum
~ HF-24AMK1 – Ultra violet detector
• Rated voltage: 24V DC • SSL listing afp:979
YBO-R/4A – Hochiki 24V conventional base YBF-RL/4AH4M – Hochiki conventional indicating base (previous model)
• Compatible with (previous model detectors)
• Compatible with
~ SLV-AS – Conventional photo optical ~ SIJ-AS – Conventional ionisation ~ SLK-A – Conventional photo optical ~ SIH-AS – Conventional ionisation
~ DCD-A – Conventional A type thermal ~ DFJ-60B – Conventional B type thermal ~ DCC-A – Conventional A type thermal ~ DFE-60B – Conventional B type thermal
~ DCD-C – Conventional C type thermal ~ DFJ-90D – Conventional D type thermal ~ DCC-C – Conventional C type thermal ~ DFE-90D – Conventional D type thermal
~ HF-24AMK1 – Ultra violet detector
06 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
07
C urrent M odel P revious M odel
D etectors D etectors
SIJ-ASN – Hochiki ionisation smoke detector SLK-AS – Hochiki photo optical smoke detector (previous model)
• Stable operation under extreme conditions • Resistant to strong vibrations & voltage fluctuation • Low standby current 35.0μA nominal • Rated voltage: 24V DC (working voltage 15-30V DC)
• Low profile, only 48mm (with base) • Reliable under conditions such as high humidity • Compatible base YBF-RL/4AH4M or YBC-R/3A • SSL listing afp:600
• Only 100mm diameter • Rated voltage: 24V DC (working voltage 15-30V DC)
• Nominal sensitivity – 0.4 MIC X • Compatible base YBO-R/4A
DCC-A - Hochiki type ‘A’ thermal detector (previous model)
• Low standby current 25.0μA nominal • SSL listing afp:1117
• Low standby current 30.0μA nominal • Rated voltage: 24V DC (working voltage 15-30V DC)
• SSL listing afp:658 • Compatible base YBF-RL/4AH4M or YBC-R/3A
VANGUARD – Vandal proof steel cage for Hochiki detectors
DH-98-ASC - Hochiki conventional duct probe DFE-60B - Hochiki type ‘B’ thermal detector (previous model)
conventional Detectors
Conventional Detectors
• Rugged steel back box with clear cover • Compact design, only W185mm x H230mm x D50mm • Low standby current 30.0μA nominal • Rated voltage: 60V DC (working voltage 0-60V DC)
• Pre mounted detector base (YBO-R/4A) • Plug in photo optical or ionisation detector • SSL listing afp:660 • Compatible base YBF-RL/4AH4M or YBC-R/3A
• No screens or filter to clean • Complete with 1m aluminium sampling tubes
• SSL listing afp:1569 DCC-C - Hochiki type ‘C’ thermal detector (previous model)
• Low standby current 35.0μA nominal • Rated voltage: 24V DC (working voltage 15-30V DC)
SPC-AS – Hochiki projected beam detector • SSL listing afp:659 • Compatible base YBF-RL/4AH4M or YBC-R/3A
• Beam length of 5m – 100m • Compact design, only W86mm x H145mm x D100mm
• Microcomputer analysis of beam data • Automatic compensation for contamination of optics DFE-90D - Hochiki type ‘D’ thermal detector (previous model)
• Low standby current 250.0μA nominal • Ideal for large open spaces eg: warehouse & theatres
• Low standby current 30.0μA nominal • Rated voltage: 60V DC (working voltage 0-60V DC)
• Sensitivity setting of 35% to 50% / span • Rated voltage: 24V DC (working voltage 15-33V DC)
• SSL listing afp:663 • Compatible base YBF-RL/4AH4M or YBC-R/3A
• SSL listing afp:2186
HF-24AMK1 – Hochiki ultraviolet flame detector SIH-AS – Hochiki ionisation smoke detector (previous model)
• Detects flames by ultraviolet radiation • 120º detection angle • Low standby current 25.0μA nominal • Rated voltage: 24V DC (working voltage 15-30V DC)
• Low profile, only 70mm (with base) • Only 100mm diameter • Compatible base YBF-RL/4AH4M or YBC-R/3A • SSL listing afp:601
• Low standby current 200.0μA nominal • Rated voltage: 24V DC (working voltage 15-30V DC)
• SSL listing afp:57 • Compatible base YBO-R/3A or YBF-RL/4AH4M YBC-R/3A – Hochiki plain base (previous model)
• Compatible with (previous model detectors)
TYPE E PROBE – Type E thermal probe ~ SLK-A – Conventional photo optical ~ SIH-AS – Conventional ionisation
• Seamless machined AISI 316 stainless steel • Corrosion and shock resistant ~ DCC-A – Conventional A type thermal ~ DFE-60B – Conventional B type thermal
• Gold plated contacts • Factory set between 60°C to 240°C ~ DCC-C – Conventional C type thermal ~ DFE-90D – Conventional D type thermal
• IP67 rating • Operating current 0.5A maximum
~ HF-24AMK1 – Ultra violet detector
• Rated voltage: 24V DC • SSL listing afp:979
YBO-R/4A – Hochiki 24V conventional base YBF-RL/4AH4M – Hochiki conventional indicating base (previous model)
• Compatible with (previous model detectors)
• Compatible with
~ SLV-AS – Conventional photo optical ~ SIJ-AS – Conventional ionisation ~ SLK-A – Conventional photo optical ~ SIH-AS – Conventional ionisation
~ DCD-A – Conventional A type thermal ~ DFJ-60B – Conventional B type thermal ~ DCC-A – Conventional A type thermal ~ DFE-60B – Conventional B type thermal
~ DCD-C – Conventional C type thermal ~ DFJ-90D – Conventional D type thermal ~ DCC-C – Conventional C type thermal ~ DFE-90D – Conventional D type thermal
~ HF-24AMK1 – Ultra violet detector
06 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
07
A nalogue P anels A nalogue P anels
- GTP P rotocol - GTP P rotocol
ANALOGUE PANELS
~ Voltage free solid state outputs which are fully programmable
~ Utilizes Hochiki programmable loop input/output devices
~ Each I/O and/or loop device has 40 characters of text for description
~ All input devices can be allocated to a specific zone with a 40 character text description
~ Up to 999 zones allowed in system
• Digifire
~ Graphical PC interface for the FireNet
~ Full monitoring and control from the graphical user interface (GUI)
• Simple operation
~ Menu driven with clear prompts for the user
~ Operator controls through touch keys and numeric keypad
~ Fire fighters controls clearly identified
~ Full system control can be replicated at any location using multiple displays
• Capacity (subject to configuration)
~ 1922 loops of 127 Hochiki analogue/addressable devices
~ High level interface to VesdaNET
~ 1000 events logged, comprising of alarms, faults, isolates & history
• Dimensions
~ Size 2 cabinet – 660H x 500W x 170D
- Optional battery box – 225H x 500W x 170D
~ Size 3 cabinet – 974H x 560W x 225D
- Optional battery box – 487H x 560W x 225D
•SSL Listing - afp: 1373
•AS compliance
~ Complies with AS 1603.4 & AS 4428.1
08 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
09
A nalogue P anels A nalogue P anels
- GTP P rotocol - GTP P rotocol
ANALOGUE PANELS
~ Voltage free solid state outputs which are fully programmable
~ Utilizes Hochiki programmable loop input/output devices
~ Each I/O and/or loop device has 40 characters of text for description
~ All input devices can be allocated to a specific zone with a 40 character text description
~ Up to 999 zones allowed in system
• Digifire
~ Graphical PC interface for the FireNet
~ Full monitoring and control from the graphical user interface (GUI)
• Simple operation
~ Menu driven with clear prompts for the user
~ Operator controls through touch keys and numeric keypad
~ Fire fighters controls clearly identified
~ Full system control can be replicated at any location using multiple displays
• Capacity (subject to configuration)
~ 1922 loops of 127 Hochiki analogue/addressable devices
~ High level interface to VesdaNET
~ 1000 events logged, comprising of alarms, faults, isolates & history
• Dimensions
~ Size 2 cabinet – 660H x 500W x 170D
- Optional battery box – 225H x 500W x 170D
~ Size 3 cabinet – 974H x 560W x 225D
- Optional battery box – 487H x 560W x 225D
•SSL Listing - afp: 1373
•AS compliance
~ Complies with AS 1603.4 & AS 4428.1
08 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
09
D etectors D etectors
- GTP P rotocol - GTP P rotocol
ALG-AS - Hochiki analogue photo optical smoke detector ACA-E – Hochiki analogue multi-sensor
• Very fast alarm response • Addressable using handheld programmer (TCH-B100) • Address stored in non volatile memory • Addressable using handheld programmer (TCH-B100)
• Address stored in non volatile memory • Dual LED’s for 360° viewing • Dual LED’s for 360° viewing • Combined photo optical & thermal elements
• Low profile, only 46mm (with base) • Only 100mm diameter • Low profile, only 52mm (with base) • Only 100mm diameter
• Low standby current 390.0μA typical • Sensitivity: variable • Sensitivity: variable • Low standby current 450.0μA typical
• Compatible base YBN-R/2NA, YBO-R/SCI • SSL listing afp:1089
• Compatible base YBN-R/2NA, YBO-R/SCI • SSL listing afp:1590
ANALOGUE Devices
• Low profile, only 46mm (with base) • Only 100mm diameter • Plug in photo optical or ionisation detector • No screens or filter to clean
• Sensitivity: variable • Low standby current 350.0μA typical • Complete with 1m aluminium sampling tubes • SSL listing afp:1569
• Compatible base YBN-R/2NA, YBO-R/SCI • SSL listing afp:1088 • Compact design, only W185mm x H230mm x D50mm
ACB-ASW - Hochiki multi-thermal detector (weatherproof) YBN-R/3 BLKANA – Hochiki black analogue base
• IP67 rating • Addressable using handheld programmer (TCH-B100)
• Dual LED’s for 360° viewing • Combination rate of rise & fixed temperature YBO-R/SCI – Hochiki analogue short circuit isolator base
• Low profile, only 46mm (with base) • Only 100mm diameter • Compatible with
• Sensitivity: variable • Low standby current 350.0μA typical ~ ALG-AS – Analogue photo optical smoke ~ ATG-AS – Analogue thermal
• Fixing base supplied • SSL listing afp: 1817 ~ AIE-AS – Analogue ionisation ~ ACA-E – Analogue multi-smoke/thermal
~ ACB-AS – Analogue multi-thermal
AIE-AS – Hochiki analogue ionisation detector
• Dual chamber for fast alarm response • Addressable using handheld programmer (TCH-B100)
• Address stored in non volatile memory • Dual LED’s for 360° viewing
• Low profile, only 52mm (with base) • Only 100mm diameter
• Sensitivity: variable • Low standby current 350.0μA typical
• Compatible base YBN-R/2NA, YBO-R/SCI • SSL listing afp:1087
10 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
11
D etectors D etectors
- GTP P rotocol - GTP P rotocol
ALG-AS - Hochiki analogue photo optical smoke detector ACA-E – Hochiki analogue multi-sensor
• Very fast alarm response • Addressable using handheld programmer (TCH-B100) • Address stored in non volatile memory • Addressable using handheld programmer (TCH-B100)
• Address stored in non volatile memory • Dual LED’s for 360° viewing • Dual LED’s for 360° viewing • Combined photo optical & thermal elements
• Low profile, only 46mm (with base) • Only 100mm diameter • Low profile, only 52mm (with base) • Only 100mm diameter
• Low standby current 390.0μA typical • Sensitivity: variable • Sensitivity: variable • Low standby current 450.0μA typical
• Compatible base YBN-R/2NA, YBO-R/SCI • SSL listing afp:1089
• Compatible base YBN-R/2NA, YBO-R/SCI • SSL listing afp:1590
ANALOGUE Devices
• Low profile, only 46mm (with base) • Only 100mm diameter • Plug in photo optical or ionisation detector • No screens or filter to clean
• Sensitivity: variable • Low standby current 350.0μA typical • Complete with 1m aluminium sampling tubes • SSL listing afp:1569
• Compatible base YBN-R/2NA, YBO-R/SCI • SSL listing afp:1088 • Compact design, only W185mm x H230mm x D50mm
ACB-ASW - Hochiki multi-thermal detector (weatherproof) YBN-R/3 BLKANA – Hochiki black analogue base
• IP67 rating • Addressable using handheld programmer (TCH-B100)
• Dual LED’s for 360° viewing • Combination rate of rise & fixed temperature YBO-R/SCI – Hochiki analogue short circuit isolator base
• Low profile, only 46mm (with base) • Only 100mm diameter • Compatible with
• Sensitivity: variable • Low standby current 350.0μA typical ~ ALG-AS – Analogue photo optical smoke ~ ATG-AS – Analogue thermal
• Fixing base supplied • SSL listing afp: 1817 ~ AIE-AS – Analogue ionisation ~ ACA-E – Analogue multi-smoke/thermal
~ ACB-AS – Analogue multi-thermal
AIE-AS – Hochiki analogue ionisation detector
• Dual chamber for fast alarm response • Addressable using handheld programmer (TCH-B100)
• Address stored in non volatile memory • Dual LED’s for 360° viewing
• Low profile, only 52mm (with base) • Only 100mm diameter
• Sensitivity: variable • Low standby current 350.0μA typical
• Compatible base YBN-R/2NA, YBO-R/SCI • SSL listing afp:1087
10 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
11
P rogrammer
M imics
D etectors S trobe
- GTP P rotocol S ounder
ANALOGUE Devices
~ DCD-C – Conventional C type thermal ~ DFG-60BLKJ – Conventional B type sealed thermal
~ DFJ-90D – Conventional D type thermal (Slave only)
A ddressable B eacon & S ounder B ase
NOTES
12 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
13
P rogrammer
M imics
D etectors S trobe
- GTP P rotocol S ounder
ANALOGUE Devices
~ DCD-C – Conventional C type thermal ~ DFG-60BLKJ – Conventional B type sealed thermal
~ DFJ-90D – Conventional D type thermal (Slave only)
A ddressable B eacon & S ounder B ase
NOTES
12 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
13
F ield D evices F ield D evices
– GTP P rotocol – GTP P rotocol
CHQ-B – Output module for bell / sounder / strobe CHQ-CP – Clean contact input module
• 2 monitored and fused outputs • Requires 24V supply •Loop powered •Non monitored general input module
• 1 monitored input • Addressed using DIP switches •Addressed using DIP switches •Low standby current 230.0μA typical
• Typical uses: • Supervised for O/C & S/C conditions
~ Bells, Sounders, Strobes MCP-E-ADD – Hochiki addressable manual call point
• Fast Response • Status LED
CHQ-Z – Conventional loops controller • Addressed using DIP switches • Complete with back box
• 2 conventional zones • Zones O/C and S/C monitored
• Requires 24V supply • 20 Hochiki conventional detectors per zone MCP-E-ADD-WP - Hochiki addressable manual call point (weatherproof)
• Addressed using DIP switches • Auxiliary output for remote fire indication • Addressed using DIP switches • Complete with back box
ANALOGUE Devices
ANALOGUE dEvices
• IP67 rating
CHQ-S – Dual input module
• Dual non monitored inputs • Individual selection of N/O or N/C contacts SQUASNIMICRO – Low current sounder
• Loop powered • Addressed using DIP switches • Ultra low 3mA current consumption • Powered from detector remote indicator output
• Colour matched to Hochiki detectors
CHQ-MZ – Mini zone module
• Loop powered • 1 conventional zone input – up to 6 conv. detectors
• Addressed using DIP switches • Zone O/C and S/C monitored S hort C ircuit I solators – GTP P rotocol
• Remote fire indication output • Supervised external power input
CHQ-SCI-S – Loop short circuit isolator
CHQ-R – Relay output module • Position at any point on loop • Short circuit isolator for signal transmission line
• 1 monitored input • 2 independent volt free relay output (N/O & N/C) • LED indication when S/C detected • Quick & reliable detection of short circuit
• Loop powered • Addressed using DIP switches
• Typical uses: YBO-R/SCI – Hochiki analogue short circuit isolator base
~ Fan controls, Fire Trips, Flow switch test solenoids • Compatible with
~ ALG-AS – Analogue photo optical smoke ~ ATG-AS – Analogue thermal
CHQ-SCI-S – Loop short circuit isolator ~ AIE-AS – Analogue ionisation ~ ACA-E – Analogue multi-smoke/thermal
• Position at any point on loop • Short circuit isolator for signal transmission line ~ ACB-AS – Analogue multi-thermal
• LED indication when S/C detected • Quick & reliable detection of short circuit
14 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
15
F ield D evices F ield D evices
– GTP P rotocol – GTP P rotocol
CHQ-B – Output module for bell / sounder / strobe CHQ-CP – Clean contact input module
• 2 monitored and fused outputs • Requires 24V supply •Loop powered •Non monitored general input module
• 1 monitored input • Addressed using DIP switches •Addressed using DIP switches •Low standby current 230.0μA typical
• Typical uses: • Supervised for O/C & S/C conditions
~ Bells, Sounders, Strobes MCP-E-ADD – Hochiki addressable manual call point
• Fast Response • Status LED
CHQ-Z – Conventional loops controller • Addressed using DIP switches • Complete with back box
• 2 conventional zones • Zones O/C and S/C monitored
• Requires 24V supply • 20 Hochiki conventional detectors per zone MCP-E-ADD-WP - Hochiki addressable manual call point (weatherproof)
• Addressed using DIP switches • Auxiliary output for remote fire indication • Addressed using DIP switches • Complete with back box
ANALOGUE Devices
ANALOGUE dEvices
• IP67 rating
CHQ-S – Dual input module
• Dual non monitored inputs • Individual selection of N/O or N/C contacts SQUASNIMICRO – Low current sounder
• Loop powered • Addressed using DIP switches • Ultra low 3mA current consumption • Powered from detector remote indicator output
• Colour matched to Hochiki detectors
CHQ-MZ – Mini zone module
• Loop powered • 1 conventional zone input – up to 6 conv. detectors
• Addressed using DIP switches • Zone O/C and S/C monitored S hort C ircuit I solators – GTP P rotocol
• Remote fire indication output • Supervised external power input
CHQ-SCI-S – Loop short circuit isolator
CHQ-R – Relay output module • Position at any point on loop • Short circuit isolator for signal transmission line
• 1 monitored input • 2 independent volt free relay output (N/O & N/C) • LED indication when S/C detected • Quick & reliable detection of short circuit
• Loop powered • Addressed using DIP switches
• Typical uses: YBO-R/SCI – Hochiki analogue short circuit isolator base
~ Fan controls, Fire Trips, Flow switch test solenoids • Compatible with
~ ALG-AS – Analogue photo optical smoke ~ ATG-AS – Analogue thermal
CHQ-SCI-S – Loop short circuit isolator ~ AIE-AS – Analogue ionisation ~ ACA-E – Analogue multi-smoke/thermal
• Position at any point on loop • Short circuit isolator for signal transmission line ~ ACB-AS – Analogue multi-thermal
• LED indication when S/C detected • Quick & reliable detection of short circuit
14 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
15
P revious D etectors
- HRE P rotocol
F ield D evices
comp a t i b l e
*HRE Protocol Devices & Detectors are NOW compatible with FireNet panel.
ALB-E - Hochiki analogue photo optical smoke detector (HRE protocol)* NOTES
• Low standby current 0.35mA nominal • Compatible base YBF-RL/2NBF
• SSL listing afp:597 • Rated voltage: 24V DC (working voltage 18-27V DC)
ANALOGUE dEvices
YBF-RL/2NBF – Hochiki analogue base (HRE protocol)*
• Compatible with
~ ATA-E – Analogue thermal (HRE protocol) ~ ALB-E – Analogue photo optical (HRE protocol)
~ AIA-E – Analogue ionisation (HRE protocol)
Field Devices
AMU-C2 – Output module for bell (HRE protocol)*
AMU-A2A – Input module for monitoring contacts (HRE protocol)*
*HRE Protocol Devices & Detectors are NOW compatible with FireNet panel.
16 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
17
P revious D etectors
- HRE P rotocol
F ield D evices
comp a t i b l e
*HRE Protocol Devices & Detectors are NOW compatible with FireNet panel.
ALB-E - Hochiki analogue photo optical smoke detector (HRE protocol)* NOTES
• Low standby current 0.35mA nominal • Compatible base YBF-RL/2NBF
• SSL listing afp:597 • Rated voltage: 24V DC (working voltage 18-27V DC)
ANALOGUE dEvices
YBF-RL/2NBF – Hochiki analogue base (HRE protocol)*
• Compatible with
~ ATA-E – Analogue thermal (HRE protocol) ~ ALB-E – Analogue photo optical (HRE protocol)
~ AIA-E – Analogue ionisation (HRE protocol)
Field Devices
AMU-C2 – Output module for bell (HRE protocol)*
AMU-A2A – Input module for monitoring contacts (HRE protocol)*
*HRE Protocol Devices & Detectors are NOW compatible with FireNet panel.
16 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
17
V esda A spirated V esda A spirated
S moke D etectors S moke D etectors
LaserFOCUS LaserSCANNER
• Ultrasonic airflow sensing • Out of the box installation & commissioning • Individual pipe detection • Laser based absolute smoke detection
• Auto learn smoke & flow • Laser-based absolute smoke detection • Adaptive scan threshold • Wide sensitivity range
• Event log up to 18000 events • Networkable with VIC-010 interface card • Up to 2,000m2 (across 4 sectors) * • VESDAnet communication
• VLF-250 up to 250m2* • 2 alarm and 1 programmable fault relays • 4 alarm levels per inlet pipe • High efficiency aspirator
• VLF-500 up to 500m2* • Offline/online configuration capability
• Dual stage air filter • 7 or 12 programmable relays option
• Programmable alarm thresholds • Multiple event logging in separate logs
• Auto learn & referencing • Event log
• SSL listing afp:1770
• Various configurations available • Recessed mounting kit available (VSP-011)
VLF-250 – Up to 250m2 coverage* VIC-010 – LaserFOCUS network card • SSL listing afp:1083
VLF-500 – Up to 500m2 coverage* VIC-020 – LaserFOCUS relay card *Dependent on exterior airflow & environmental conditions
*Dependent on exterior airflow & environmental conditions
VLS-200 – Blank, blank, blank, 7 relays fitted
LaserCOMPACT VLS-300 – Blank, blank, blank, 12 relays fitted
• Single pipe inlet • Optional remote display & relays (VLC-505 only) VLS-204 – Blank, blank, display, 7 relays fitted
• Up to 800m2 * • Laser based absolute smoke detection VLS-304 – Blank, blank, display, 12 relays fitted
• Five status LED’s • 3 Relays = Alert/Fault, Pre-alarm & Fire
VLS-210 – Blank, programmer, blank, 7 relays fitted
• Wide sensitivity range • VesdaNET communication (VLC-505 only)
VESDA
VESDA
• Dual stage dust filter • Referencing (VLC-505 only) VLS-310 – Blank, programmer, blank, 12 relays fitted
• Air flow monitoring • SSL listing afp:1083 VLS-214 – Blank, display, programmer, 7 relays fitted
• Auto learn VLS-314 – Blank, display, programmer, 12 relays fitted
*Dependent on exterior airflow & environmental conditions
VLS-600 – Blank, blank, blank with Fire 1 & OK LEDs, 7 relays fitted
VLC-500 – Relays only VLS-700 – Blank, blank, blank with Fire 1 & OK LEDs, 12 relays fitted
VLC-505 – VesdaNET
VESDA Ex d – Explosion proof VLC-505
LaserPLUS
• Ex d IIB T6 certified • Ex d cert. Flame arrestors on inlet & exhaust
• 4 configurable alarm levels • Laser based absolute smoke detection
• Single pipe inlet • Laser based absolute smoke detection
• 4 inlet pipes • Up to 2,000m2 *
• Up to 800m2 * • 3 Relays = Alert/Fault, Pre-alarm & Fire
• High efficiency aspirator • Airflow supervisor per inlet pipe
• Five status LED’s • Optional remote display and relays
• Dual stage air filter • 7 programmable relays
• VESDAnet communication • Auto learn & referencing • Wide sensitivity range • Dual stage dust filter
• Event log • Recessed mounting kit available (VSP-011) • Auto learn & referencing • Air flow monitoring
• Available in various configurations • SSL listing afp:1083 • VesdaNET communication • Simple mounting design
*Dependent on exterior airflow & environmental conditions • Hinged door
*Dependent on exterior airflow & environmental conditions
VLP-000 – Blank, blank, blank plates fitted
VLP-002 – Blank, blank, display fitted
VLP-012 – Blank, display, programmer fitted VLX-100 – VLC-505 in explosion proof housing with flame arrestors
VLP-400 – Blank, blank, blank with Fire 1 & OK LEDs fitted
18 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
19
V esda A spirated V esda A spirated
S moke D etectors S moke D etectors
LaserFOCUS LaserSCANNER
• Ultrasonic airflow sensing • Out of the box installation & commissioning • Individual pipe detection • Laser based absolute smoke detection
• Auto learn smoke & flow • Laser-based absolute smoke detection • Adaptive scan threshold • Wide sensitivity range
• Event log up to 18000 events • Networkable with VIC-010 interface card • Up to 2,000m2 (across 4 sectors) * • VESDAnet communication
• VLF-250 up to 250m2* • 2 alarm and 1 programmable fault relays • 4 alarm levels per inlet pipe • High efficiency aspirator
• VLF-500 up to 500m2* • Offline/online configuration capability
• Dual stage air filter • 7 or 12 programmable relays option
• Programmable alarm thresholds • Multiple event logging in separate logs
• Auto learn & referencing • Event log
• SSL listing afp:1770
• Various configurations available • Recessed mounting kit available (VSP-011)
VLF-250 – Up to 250m2 coverage* VIC-010 – LaserFOCUS network card • SSL listing afp:1083
VLF-500 – Up to 500m2 coverage* VIC-020 – LaserFOCUS relay card *Dependent on exterior airflow & environmental conditions
*Dependent on exterior airflow & environmental conditions
VLS-200 – Blank, blank, blank, 7 relays fitted
LaserCOMPACT VLS-300 – Blank, blank, blank, 12 relays fitted
• Single pipe inlet • Optional remote display & relays (VLC-505 only) VLS-204 – Blank, blank, display, 7 relays fitted
• Up to 800m2 * • Laser based absolute smoke detection VLS-304 – Blank, blank, display, 12 relays fitted
• Five status LED’s • 3 Relays = Alert/Fault, Pre-alarm & Fire
VLS-210 – Blank, programmer, blank, 7 relays fitted
• Wide sensitivity range • VesdaNET communication (VLC-505 only)
VESDA
VESDA
• Dual stage dust filter • Referencing (VLC-505 only) VLS-310 – Blank, programmer, blank, 12 relays fitted
• Air flow monitoring • SSL listing afp:1083 VLS-214 – Blank, display, programmer, 7 relays fitted
• Auto learn VLS-314 – Blank, display, programmer, 12 relays fitted
*Dependent on exterior airflow & environmental conditions
VLS-600 – Blank, blank, blank with Fire 1 & OK LEDs, 7 relays fitted
VLC-500 – Relays only VLS-700 – Blank, blank, blank with Fire 1 & OK LEDs, 12 relays fitted
VLC-505 – VesdaNET
VESDA Ex d – Explosion proof VLC-505
LaserPLUS
• Ex d IIB T6 certified • Ex d cert. Flame arrestors on inlet & exhaust
• 4 configurable alarm levels • Laser based absolute smoke detection
• Single pipe inlet • Laser based absolute smoke detection
• 4 inlet pipes • Up to 2,000m2 *
• Up to 800m2 * • 3 Relays = Alert/Fault, Pre-alarm & Fire
• High efficiency aspirator • Airflow supervisor per inlet pipe
• Five status LED’s • Optional remote display and relays
• Dual stage air filter • 7 programmable relays
• VESDAnet communication • Auto learn & referencing • Wide sensitivity range • Dual stage dust filter
• Event log • Recessed mounting kit available (VSP-011) • Auto learn & referencing • Air flow monitoring
• Available in various configurations • SSL listing afp:1083 • VesdaNET communication • Simple mounting design
*Dependent on exterior airflow & environmental conditions • Hinged door
*Dependent on exterior airflow & environmental conditions
VLP-000 – Blank, blank, blank plates fitted
VLP-002 – Blank, blank, display fitted
VLP-012 – Blank, display, programmer fitted VLX-100 – VLC-505 in explosion proof housing with flame arrestors
VLP-400 – Blank, blank, blank with Fire 1 & OK LEDs fitted
18 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
19
F ilters
R emote U nits P ower S upplies
19” R acks S oftware
LaserFOCUS Remote Units VSP-005 - Filter assembly (VLF, VLC, VLP & VLS)
VRT-V00 - Remote box fitted with VLF display and 7 relays
E700-FMK-2 - Filter for Vesda Mk2 system
LaserCOMPACT Remote Units
VRT-J00 - Remote box fitted with VLC-505 display and 7 relays E700-FMK-4 - Filter for E70D (scanner & Mini) & E700
VRT-K00 - Remote box fitted with VLC-505 display and no relays
E700-FILASSY - In line pre filter for any Vesda detector
LaserPLUS Remote Units
VRT-200 - Remote box fitted with VLP display and 7 relays
E700-FILFOAM - Foam filter only to suit E700-FMK-4 & E700-FILASSY
VRT-500 - Remote box fitted with blank plate DRP & 7 relay card
VRT-600 - Remote box fitted with VLP display and no relays
VRT-F00 - Remote box fitted with blank plate DRP &12 relay card
F ire N et HLI
LaserSCANNER Remote Units
VRT-400 - Remote box fitted with VLS display and 7 relays VHX-FIRENET - FireNet/VESDA high level interface
VRT-700 - Remote box fitted with VLS display and no relays
VESDA
VESDA
VRT-800 - Remote box fitted with VLS display and 12 relays Please contact us on 1300 INCITE for more information on the FireNet HLI
VRT-900 - Remote box fitted with blank plate DRP & 12 relay card
VRT-E00 - Remote box fitted with blank plate DRP & 7 relay card
V esda S oftware & A ccessories
General Remote Units
VRT-100 - Remote box fitted with programmer
VHH-100 - Hand held programmer & cable
VRT-300 - Remote box fitted with VesdaNET socket
VHX-0200 - VesdaNET PC link HLI
VRT-A10 - Remote box fitted with analogue output module
20 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
21
F ilters
R emote U nits P ower S upplies
19” R acks S oftware
LaserFOCUS Remote Units VSP-005 - Filter assembly (VLF, VLC, VLP & VLS)
VRT-V00 - Remote box fitted with VLF display and 7 relays
E700-FMK-2 - Filter for Vesda Mk2 system
LaserCOMPACT Remote Units
VRT-J00 - Remote box fitted with VLC-505 display and 7 relays E700-FMK-4 - Filter for E70D (scanner & Mini) & E700
VRT-K00 - Remote box fitted with VLC-505 display and no relays
E700-FILASSY - In line pre filter for any Vesda detector
LaserPLUS Remote Units
VRT-200 - Remote box fitted with VLP display and 7 relays
E700-FILFOAM - Foam filter only to suit E700-FMK-4 & E700-FILASSY
VRT-500 - Remote box fitted with blank plate DRP & 7 relay card
VRT-600 - Remote box fitted with VLP display and no relays
VRT-F00 - Remote box fitted with blank plate DRP &12 relay card
F ire N et HLI
LaserSCANNER Remote Units
VRT-400 - Remote box fitted with VLS display and 7 relays VHX-FIRENET - FireNet/VESDA high level interface
VRT-700 - Remote box fitted with VLS display and no relays
VESDA
VESDA
VRT-800 - Remote box fitted with VLS display and 12 relays Please contact us on 1300 INCITE for more information on the FireNet HLI
VRT-900 - Remote box fitted with blank plate DRP & 12 relay card
VRT-E00 - Remote box fitted with blank plate DRP & 7 relay card
V esda S oftware & A ccessories
General Remote Units
VRT-100 - Remote box fitted with programmer
VHH-100 - Hand held programmer & cable
VRT-300 - Remote box fitted with VesdaNET socket
VHX-0200 - VesdaNET PC link HLI
VRT-A10 - Remote box fitted with analogue output module
20 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
21
V esda S pare R epairs
P arts T raining
VSP-004 - Display Module for LaserSCANNER on 1300 INCITE for more information.
VSP-006 - Detector chassis & manifold assembly for LaserPLUS
VSP-007 - Remote termination card no relays
VSP-008 - Remote termination card with 7 relays
V esda T raining
Please contact us on 1300 INCITE for Vesda Accreditation training courses.
VSP-009 - Detector chassis & manifold assembly for LaserSCANNER
VSP-011 - Recess mounting kit (VLP & VLS)
VSP-012 - Remote recess mounting kit
VSP-013 - Cover assembly with EMC shields (VLP & VLS) NOTES
VSP-014 - Head termination card with 7 relays
VSP-015 - Detector aspirator assembly (VLP & VLS)
VSP-016 - Head termination card with 12 relays (VLS only)
VSP-018 - Filter switch assembly (VLP & VLS)
VESDA
VESDA
VSP-019 - Filter cover (VLP & VLS)
VSP-020 - Screw covers (2)
VSP-021 - Pipe adaptors 25mm to 27mm (4)
VSP-022 - Mounting box detector
VSP-023 - Front cover (VLC-505)
VSP-024 - Front cover (VLC-500)
VSP-100 - Blank plate non-EMC, Fire 1 & OK LEDs
VSP-102 - Remote relay processor without display
VSP-103 - Remote relay processor without display (VLS)
VSP-200 - Blank plate EMC painted, without VESDA logo
VSP-208 - Remote termination card with 12 relays (VLS only)
VSP-300 - Blank plate non EMC without VESDA logo
VSP-501 - VLC aspirator
VSP-502 - Remote Display (VLC)
VSP-509 - VESDAlink RS232 9P-9P cable
VSP-510 - Relays only termination card (VLC-500)
VSP-515 - VesdaNET termination card (VLC-505)
VSP-715 - Aspirator for VLF-250/500
22 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
23
V esda S pare R epairs
P arts T raining
VSP-004 - Display Module for LaserSCANNER on 1300 INCITE for more information.
VSP-006 - Detector chassis & manifold assembly for LaserPLUS
VSP-007 - Remote termination card no relays
VSP-008 - Remote termination card with 7 relays
V esda T raining
Please contact us on 1300 INCITE for Vesda Accreditation training courses.
VSP-009 - Detector chassis & manifold assembly for LaserSCANNER
VSP-011 - Recess mounting kit (VLP & VLS)
VSP-012 - Remote recess mounting kit
VSP-013 - Cover assembly with EMC shields (VLP & VLS) NOTES
VSP-014 - Head termination card with 7 relays
VSP-015 - Detector aspirator assembly (VLP & VLS)
VSP-016 - Head termination card with 12 relays (VLS only)
VSP-018 - Filter switch assembly (VLP & VLS)
VESDA
VESDA
VSP-019 - Filter cover (VLP & VLS)
VSP-020 - Screw covers (2)
VSP-021 - Pipe adaptors 25mm to 27mm (4)
VSP-022 - Mounting box detector
VSP-023 - Front cover (VLC-505)
VSP-024 - Front cover (VLC-500)
VSP-100 - Blank plate non-EMC, Fire 1 & OK LEDs
VSP-102 - Remote relay processor without display
VSP-103 - Remote relay processor without display (VLS)
VSP-200 - Blank plate EMC painted, without VESDA logo
VSP-208 - Remote termination card with 12 relays (VLS only)
VSP-300 - Blank plate non EMC without VESDA logo
VSP-501 - VLC aspirator
VSP-502 - Remote Display (VLC)
VSP-509 - VESDAlink RS232 9P-9P cable
VSP-510 - Relays only termination card (VLC-500)
VSP-515 - VesdaNET termination card (VLC-505)
VSP-715 - Aspirator for VLF-250/500
22 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
23
P ipes P ipes
F ittings F ittings
E700-CSC - Capillary tube E700-CT - Capillary tube for E700-EC - 25mm E700-SP - Sampling point E700-SP-DCL - Sample point E700-SPLR - Sampling
connector sample points End cap decal (200 roll) point label (red)
E700-HASP - Heat activated E700-J - 2 into 1 pipe joiner E700-LB - Long radius E700-SRB - Base for heat E700-T - Solid ‘T’ E700-TA - Trunk adaptor
VESDA
VESDA
sample point (parallel pipes) 90° bend activated sample point junction pipe for sample points
E700-P - 4 metre Vesda E700-PC - Pipe Clips E700-PJ - Straight E700-Y - 2 into 1 pipe E700-SP-KIT - Sample point kit, E700-HASP-KIT - Heat activated
pipe (25mm) coupling joiner (45°) contains: – * sample point kit, contains: - *
• 1 x E700-CSC • 1 x E700-HASP
• 1 x E700-SP • 1 x E700-SRB
• 1 x E700-TA • 1 x E700-TA
• 1 x E700-SPLR • 2 x E700-CSC
24 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
25
P ipes P ipes
F ittings F ittings
E700-CSC - Capillary tube E700-CT - Capillary tube for E700-EC - 25mm E700-SP - Sampling point E700-SP-DCL - Sample point E700-SPLR - Sampling
connector sample points End cap decal (200 roll) point label (red)
E700-HASP - Heat activated E700-J - 2 into 1 pipe joiner E700-LB - Long radius E700-SRB - Base for heat E700-T - Solid ‘T’ E700-TA - Trunk adaptor
VESDA
VESDA
sample point (parallel pipes) 90° bend activated sample point junction pipe for sample points
E700-P - 4 metre Vesda E700-PC - Pipe Clips E700-PJ - Straight E700-Y - 2 into 1 pipe E700-SP-KIT - Sample point kit, E700-HASP-KIT - Heat activated
pipe (25mm) coupling joiner (45°) contains: – * sample point kit, contains: - *
• 1 x E700-CSC • 1 x E700-HASP
• 1 x E700-SP • 1 x E700-SRB
• 1 x E700-TA • 1 x E700-TA
• 1 x E700-SPLR • 2 x E700-CSC
24 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
25
E wis OWS
OWS A ccessories
Warning Systems
Evac-40 - 40Watt Evacuation module • Dimensions 95L x 55W x 25H • End of line 4K7 ohms
• 40watt output • Operating voltage 23-30Vdc • Monitor and switch alert & evacuate strobe indicators
• Standby current 140mA • Maximum speaker impedance 250 ohms
• Loaded current 2.8A • Dimensions LMU-4 - 4 speaker circuit line monitoring card
~ Transformer 100L x 60W x 60H • 100V line voltage in & out • Maximum load output 250watts per card
~ Card 170L x 90W x 60H • Current draw 90mA • Dimensions 140L x 75W x 22H
• End of line 22K
Evac-60 - 60Watt Evacuation module
• 60watt output • Operating voltage 23-30Vdc
• Standby current 160mA • Dimensions 220L x 210W x 100H
• Loaded current 3.8A • Maximum speaker impedance 166 ohms
26 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
27
E wis OWS
OWS A ccessories
Warning Systems
Evac-40 - 40Watt Evacuation module • Dimensions 95L x 55W x 25H • End of line 4K7 ohms
• 40watt output • Operating voltage 23-30Vdc • Monitor and switch alert & evacuate strobe indicators
• Standby current 140mA • Maximum speaker impedance 250 ohms
• Loaded current 2.8A • Dimensions LMU-4 - 4 speaker circuit line monitoring card
~ Transformer 100L x 60W x 60H • 100V line voltage in & out • Maximum load output 250watts per card
~ Card 170L x 90W x 60H • Current draw 90mA • Dimensions 140L x 75W x 22H
• End of line 22K
Evac-60 - 60Watt Evacuation module
• 60watt output • Operating voltage 23-30Vdc
• Standby current 160mA • Dimensions 220L x 210W x 100H
• Loaded current 3.8A • Maximum speaker impedance 166 ohms
26 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
27
S peakers S peakers
H orns H orns
S trobes S trobes
SPG100 – 100mm Flush mount speaker SPSM – 100mm Surface mount speaker
• 5 tappings up to 5W •100V line dual cone fire / evac speaker • 5 tappings up to 5W • 100V line dual cone fire / evac speaker
• Transformer safety cover • Uses 100mm grill (SPGG) • Transformer safety cover • Back box with concealed internal fixings
Warning Systems
SPGG-B – 100mm black slimline grill HORN-SS – 10 Watt Marine horn speaker
• As above, stainless steel fitting for marine/outdoor use
SPQF100 – 100mm Quick fit speaker
• Quick to install • Snap fits to any 10-13mm thickness ceiling BEACON-R - 24VDC Red strobe
• 5 tappings up to 5W • Transformer safety cover • No start up current surge • Low current consumption - 90mA
• Flash rate 60/min • Only 75mm deep with shallow base
Also available • IP65 with deep base • Small diameter, only 93mm
SPQF100-B – as above in black • Operating voltage 20-30Vdc
SPQF200 – 200mm Quick fit speaker
SPQF200-B – 200mm black quick fit speaker BEACON-A - 24VDC Amber strobe
• As above with amber lens and base
SPQFTILEMT – Tile mount bracket for SPQF100
• Minimises sag of fibre ceiling tiles • Fits inside tile T-bars for maximum support BEACON-T3 - 24VDC Clear strobe
• Available for 100mm & 200mm ‘Quick fit’ speakers • “T3” temporal pattern as required by AS1670.4 - 2004
28 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
29
S peakers S peakers
H orns H orns
S trobes S trobes
SPG100 – 100mm Flush mount speaker SPSM – 100mm Surface mount speaker
• 5 tappings up to 5W •100V line dual cone fire / evac speaker • 5 tappings up to 5W • 100V line dual cone fire / evac speaker
• Transformer safety cover • Uses 100mm grill (SPGG) • Transformer safety cover • Back box with concealed internal fixings
Warning Systems
SPGG-B – 100mm black slimline grill HORN-SS – 10 Watt Marine horn speaker
• As above, stainless steel fitting for marine/outdoor use
SPQF100 – 100mm Quick fit speaker
• Quick to install • Snap fits to any 10-13mm thickness ceiling BEACON-R - 24VDC Red strobe
• 5 tappings up to 5W • Transformer safety cover • No start up current surge • Low current consumption - 90mA
• Flash rate 60/min • Only 75mm deep with shallow base
Also available • IP65 with deep base • Small diameter, only 93mm
SPQF100-B – as above in black • Operating voltage 20-30Vdc
SPQF200 – 200mm Quick fit speaker
SPQF200-B – 200mm black quick fit speaker BEACON-A - 24VDC Amber strobe
• As above with amber lens and base
SPQFTILEMT – Tile mount bracket for SPQF100
• Minimises sag of fibre ceiling tiles • Fits inside tile T-bars for maximum support BEACON-T3 - 24VDC Clear strobe
• Available for 100mm & 200mm ‘Quick fit’ speakers • “T3” temporal pattern as required by AS1670.4 - 2004
28 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
29
S trobe sets
MCP
WIP
Warning Systems
WIP – Red warden intercom phone
• Selectable line impedance 600Ω or 4.7KΩ • Separate speaker for call tone
• Simple two wire connection • Includes wall mounting bracket
• SSL approved, complies with AS 2220
Accessories
KAC-GLASS - Spare glass, pack of 5
KAC-FLAP - Clear anti-tamper cover
30 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
31
S trobe sets
MCP
WIP
Warning Systems
WIP – Red warden intercom phone
• Selectable line impedance 600Ω or 4.7KΩ • Separate speaker for call tone
• Simple two wire connection • Includes wall mounting bracket
• SSL approved, complies with AS 2220
Accessories
KAC-GLASS - Spare glass, pack of 5
KAC-FLAP - Clear anti-tamper cover
30 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
31
M anual S ounders
C all P oints S trobes
KAC-RED – Conventional red manual call point ROSHNI - 9-28VDC Electronic sounder
• Plug ‘n’ play installation • 470Ω resistor fitted • 32 selectable tones • Second tone for two stage alarms
• Maximum voltage 30VDC • Current rating 2 Amps • Low current consumption • Up to 111dB (tone dependent)
• Operating temperature -30° to +70° • Anti-tamper facility available • Volume control • Only 75mm deep with shallow base
• IP65 with deep base • Small diameter, only 93mm
• 9V – 28V operation without adjustment
KAC-RED-RP - Conventional red rainproof MCP (IP55)
• IP55 rating • Maximum voltage 30VDC
• Current rating 3 Amps • Operating temperature -30° to +70°
BEACON-R - 24VDC Red strobe
• Anti-tamper facility available
• No start up current surge • Operating voltage 20-30Vdc
• Flash rate 60/min • Low current consumption - 90mA
KAC-RED-WP - Conventional red waterproof MCP (IP67) • IP65 with deep base • Only 75mm deep with shallow base
• IP67 rating • Maximum voltage 30VDC • Small diameter, only 93mm
• Current rating 5 Amps • Operating temperature -30° to +70°
• Anti-tamper facility available BEACON-A - 24VDC Amber strobe
ANCILLARIES
ANCILLARIES
• As above with amber lens and base
Also available
KAC-WHITE – Conventional white manual call point STR-LAB - Strobe ‘FIRE’ label to suit BEACON-R
• Foam PVC label • Complies to AS1670.1 2004
KAC-WHITE-RP - Conventional white rainproof MCP (IP55)
• Pre drilled to suit BEACON-R • Red lettering on white background
KAC-WHITE-WP - Conventional white waterproof MCP (IP67)
KAC-GREEN - Conventional green manual call point
FLASHNI - Combined sounder strobe
• Volume control • IP65 with deep base
Accessories
• 2 preset tones • Compact design 92mm deep & 93mm dia.
KAC-GLASS - Spare glass, pack of 5 • Up to 101dB at 1 metre • Low current consumption - 68mA (average)
KAC-FLAP - Clear anti-tamper cover for all KAC BGA • Flash rate 60/min • Automatic sounder/strobe synchronisation
• Operating voltage 18-30Vdc
SQUASHNI – Sounder
• Fixing platform for Hochiki detector bases • Blank cover for use as stand alone sounder
• Colour matched to Hochiki detectors • Operating voltage 10-28Vdc
• Operating current 8-35mA • Ultra slim profile for unobtrusive installation
(Tone dependant) (30mm deep)
32 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
33
M anual S ounders
C all P oints S trobes
KAC-RED – Conventional red manual call point ROSHNI - 9-28VDC Electronic sounder
• Plug ‘n’ play installation • 470Ω resistor fitted • 32 selectable tones • Second tone for two stage alarms
• Maximum voltage 30VDC • Current rating 2 Amps • Low current consumption • Up to 111dB (tone dependent)
• Operating temperature -30° to +70° • Anti-tamper facility available • Volume control • Only 75mm deep with shallow base
• IP65 with deep base • Small diameter, only 93mm
• 9V – 28V operation without adjustment
KAC-RED-RP - Conventional red rainproof MCP (IP55)
• IP55 rating • Maximum voltage 30VDC
• Current rating 3 Amps • Operating temperature -30° to +70°
BEACON-R - 24VDC Red strobe
• Anti-tamper facility available
• No start up current surge • Operating voltage 20-30Vdc
• Flash rate 60/min • Low current consumption - 90mA
KAC-RED-WP - Conventional red waterproof MCP (IP67) • IP65 with deep base • Only 75mm deep with shallow base
• IP67 rating • Maximum voltage 30VDC • Small diameter, only 93mm
• Current rating 5 Amps • Operating temperature -30° to +70°
• Anti-tamper facility available BEACON-A - 24VDC Amber strobe
ANCILLARIES
ANCILLARIES
• As above with amber lens and base
Also available
KAC-WHITE – Conventional white manual call point STR-LAB - Strobe ‘FIRE’ label to suit BEACON-R
• Foam PVC label • Complies to AS1670.1 2004
KAC-WHITE-RP - Conventional white rainproof MCP (IP55)
• Pre drilled to suit BEACON-R • Red lettering on white background
KAC-WHITE-WP - Conventional white waterproof MCP (IP67)
KAC-GREEN - Conventional green manual call point
FLASHNI - Combined sounder strobe
• Volume control • IP65 with deep base
Accessories
• 2 preset tones • Compact design 92mm deep & 93mm dia.
KAC-GLASS - Spare glass, pack of 5 • Up to 101dB at 1 metre • Low current consumption - 68mA (average)
KAC-FLAP - Clear anti-tamper cover for all KAC BGA • Flash rate 60/min • Automatic sounder/strobe synchronisation
• Operating voltage 18-30Vdc
SQUASHNI – Sounder
• Fixing platform for Hochiki detector bases • Blank cover for use as stand alone sounder
• Colour matched to Hochiki detectors • Operating voltage 10-28Vdc
• Operating current 8-35mA • Ultra slim profile for unobtrusive installation
(Tone dependant) (30mm deep)
32 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
33
S peakers S peakers
H orns H orns
SPG100 – 100mm Flush mount speaker SPSM – 100mm Surface mount speaker
• 5 tappings up to 5W • 100V line dual cone fire / evac speaker • 5 tappings up to 5W • 100V line dual cone fire / evac speaker
• Transformer safety cover • Uses 100mm grill (SPGG) • Transformer safety cover • Back box with concealed internal fixings
ANCILLARIES
SPQF100 – 100mm Quick fit speaker
• Quick to install • Snap fits to any 10-13mm thickness ceiling NOTES
• 5 tappings up to 5W • Transformer safety cover
Also available
SPQF100-B – as above in black
SPQF200 – 200mm Quick fit speaker
SPQF200-B – 200mm black quick fit speaker
34 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
35
S peakers S peakers
H orns H orns
SPG100 – 100mm Flush mount speaker SPSM – 100mm Surface mount speaker
• 5 tappings up to 5W • 100V line dual cone fire / evac speaker • 5 tappings up to 5W • 100V line dual cone fire / evac speaker
• Transformer safety cover • Uses 100mm grill (SPGG) • Transformer safety cover • Back box with concealed internal fixings
ANCILLARIES
SPQF100 – 100mm Quick fit speaker
• Quick to install • Snap fits to any 10-13mm thickness ceiling NOTES
• 5 tappings up to 5W • Transformer safety cover
Also available
SPQF100-B – as above in black
SPQF200 – 200mm Quick fit speaker
SPQF200-B – 200mm black quick fit speaker
34 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
35
S trobe S ets M agnetic D oor
WIP H olders
STRRED-AMB-LP - Red & Amber strobe set on metal plate DM500 - Doormouse 50KG wall mount door holder
• Low current draw 100mA • Sturdy white powder coated steel chassis • 50Kg holding force • Compact white ABS plastic housing (wall mount)
• Simple bolt on installation • Conduit knockouts for cable entry • Rated voltage 24VDC • Operating current 43mA
• Operating voltage 24Vdc • Dimensions 285L x 122W x 85H • Zero residual magnetism
ANCILLARIES
• Simple two wire connection • SSL approved, complies with AS 2220 DP-200 – 200mm Universal mount door holder
• Includes wall mounting bracket • 200mm steel post (white) • Rated voltage 24VDC
• Floor, ceiling or wall mount • Operating current 43mA
• 50kg holding force • Zero residual magnetism
NOTES
DH-CHROME – Chrome finish door holder
• 11.5Kg holding force • Rated voltage 24VDC
• Operating Current 66mA • Chrome finish surface mount kit available
• High quality chrome finish c/w matching keeper plate, also available in brass finish
36 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
37
S trobe S ets M agnetic D oor
WIP H olders
STRRED-AMB-LP - Red & Amber strobe set on metal plate DM500 - Doormouse 50KG wall mount door holder
• Low current draw 100mA • Sturdy white powder coated steel chassis • 50Kg holding force • Compact white ABS plastic housing (wall mount)
• Simple bolt on installation • Conduit knockouts for cable entry • Rated voltage 24VDC • Operating current 43mA
• Operating voltage 24Vdc • Dimensions 285L x 122W x 85H • Zero residual magnetism
ANCILLARIES
• Simple two wire connection • SSL approved, complies with AS 2220 DP-200 – 200mm Universal mount door holder
• Includes wall mounting bracket • 200mm steel post (white) • Rated voltage 24VDC
• Floor, ceiling or wall mount • Operating current 43mA
• 50kg holding force • Zero residual magnetism
NOTES
DH-CHROME – Chrome finish door holder
• 11.5Kg holding force • Rated voltage 24VDC
• Operating Current 66mA • Chrome finish surface mount kit available
• High quality chrome finish c/w matching keeper plate, also available in brass finish
36 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
37
P ower S upplies
R emote I ndicators S igns
B atteries T est E quipment
Remote Indicators
P ower S upplies
“Fire alarm in…”
A range of Stand alone power supplies and batteries are available. Please contact us on
REM-CR - COOLROOM
1300 INCITE for a power supply to suit your requirements.
REM-CS - CONCEALED SPACE
REM-CU - CUPBOARD
REM-DC - DUCT
S igns
REM-RA - RETURN AIR
REM-LIFT - LIFT SHAFT A range of warning signs are available. Contact us on 1300 INCITE for more information.
REM-RF - ROOF SPACE
REM-RM - ROOM
REM-SB - SWITCHBOARD
REM-CL - CEILING T est E quipment
REM-UF - UNDER FLOOR
ANCILLARIES
ANCILLARIES
SMOKE-HSG – Canned smoke (70.5g)
A range of other size batteries are available. Please contact us on 1300 INCITE for a battery to Also available for hire
suit your requirements. Spectrex flame detector tester
Hochiki beam detector (SPC-AS) tester
38 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
39
P ower S upplies
R emote I ndicators S igns
B atteries T est E quipment
Remote Indicators
P ower S upplies
“Fire alarm in…”
A range of Stand alone power supplies and batteries are available. Please contact us on
REM-CR - COOLROOM
1300 INCITE for a power supply to suit your requirements.
REM-CS - CONCEALED SPACE
REM-CU - CUPBOARD
REM-DC - DUCT
S igns
REM-RA - RETURN AIR
REM-LIFT - LIFT SHAFT A range of warning signs are available. Contact us on 1300 INCITE for more information.
REM-RF - ROOF SPACE
REM-RM - ROOM
REM-SB - SWITCHBOARD
REM-CL - CEILING T est E quipment
REM-UF - UNDER FLOOR
ANCILLARIES
ANCILLARIES
SMOKE-HSG – Canned smoke (70.5g)
A range of other size batteries are available. Please contact us on 1300 INCITE for a battery to Also available for hire
suit your requirements. Spectrex flame detector tester
Hochiki beam detector (SPC-AS) tester
38 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
39
S pecial A pplication I ntrinsically S afe
D etection M arine
Intrinsically safe barriers & warning devices are also available. Please contact us on 1300 INCITE
Firewire (linear heat cable) for more information.
Please contact us on 1300 INCITE for information and specification on Firewire.
SPECIAL APPLICATIONS
SPECIAL APPLICATIONS
Aspirated M arine D etectors
Please refer to the Vesda section on page 18
SLR-EM – Hochiki marine conventional photo electric smoke detector
DCD-RE1EM - Hochiki marine conventional thermal detector
NOTES YBN-R/4M – Hochiki marine conventional base
Other
VANGUARD – Vandal proof steel cage for Hochiki detectors
NOTES
40 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
41
S pecial A pplication I ntrinsically S afe
D etection M arine
Intrinsically safe barriers & warning devices are also available. Please contact us on 1300 INCITE
Firewire (linear heat cable) for more information.
Please contact us on 1300 INCITE for information and specification on Firewire.
SPECIAL APPLICATIONS
SPECIAL APPLICATIONS
Aspirated M arine D etectors
Please refer to the Vesda section on page 18
SLR-EM – Hochiki marine conventional photo electric smoke detector
DCD-RE1EM - Hochiki marine conventional thermal detector
NOTES YBN-R/4M – Hochiki marine conventional base
Other
VANGUARD – Vandal proof steel cage for Hochiki detectors
NOTES
40 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
41
T ools T ools
S undries S undries
Tools Components
T2312A – 140mm Holesaw - to suit SPQF100 - 100mm quick fit speaker FP01 – Assorted fuse pack
GASSOLD – 100W gas soldering iron – auto ignition RP01 – Assorted resistor pack
SOLDER – Tube of 1mm resin core solder (3m) RELAY – 24V relay & mounting base 24V 10A DPDT
HEADLED – 3 LED torch c/w headband TERM01 – Terminal strip block (12)
CRIMPTL – Ratchet crimper, 0.25mm – 6.0mm range • Rated 400V @ 6A • 2.8mm cable entry with wire protection
WIREST – Automatic wire stripper
TERM02 - Terminal strip block (12)
Aerosols • Rated 400V @ 10A • 3.4mm cable entry with wire protection
DUSTOFF – Can compressed air – suits detector & internal panel cleaning
BUTANE – Can butane gas to suit GASSOLD CRIMPLG – Assorted crimp lugs pack
MISCELLANEOUS
MISCELLANEOUS
CLEANSOL – Electronic cleaning solvent
Interface Leads
Fixings LD/USB-DB9 – 35cm lead, USB A to DB9 serial
CT100 – 100mm cable ties (100 pack, natural color) • Not compatible with all laptops • For use in conjunction with FireNet download cable
Enclosures
JB-UB2 – ABS grey plastic box for field modules etc. Cable
• Dimensions – 197L x 112W x 62H
Please contact us on 1300 INCITE for an enclosure to suit your requirements. Also available
Fire rated cable. Please contact us on 1300 INCITE
42 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
43
T ools T ools
S undries S undries
Tools Components
T2312A – 140mm Holesaw - to suit SPQF100 - 100mm quick fit speaker FP01 – Assorted fuse pack
GASSOLD – 100W gas soldering iron – auto ignition RP01 – Assorted resistor pack
SOLDER – Tube of 1mm resin core solder (3m) RELAY – 24V relay & mounting base 24V 10A DPDT
HEADLED – 3 LED torch c/w headband TERM01 – Terminal strip block (12)
CRIMPTL – Ratchet crimper, 0.25mm – 6.0mm range • Rated 400V @ 6A • 2.8mm cable entry with wire protection
WIREST – Automatic wire stripper
TERM02 - Terminal strip block (12)
Aerosols • Rated 400V @ 10A • 3.4mm cable entry with wire protection
DUSTOFF – Can compressed air – suits detector & internal panel cleaning
BUTANE – Can butane gas to suit GASSOLD CRIMPLG – Assorted crimp lugs pack
MISCELLANEOUS
MISCELLANEOUS
CLEANSOL – Electronic cleaning solvent
Interface Leads
Fixings LD/USB-DB9 – 35cm lead, USB A to DB9 serial
CT100 – 100mm cable ties (100 pack, natural color) • Not compatible with all laptops • For use in conjunction with FireNet download cable
Enclosures
JB-UB2 – ABS grey plastic box for field modules etc. Cable
• Dimensions – 197L x 112W x 62H
Please contact us on 1300 INCITE for an enclosure to suit your requirements. Also available
Fire rated cable. Please contact us on 1300 INCITE
42 www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
43
INCITE FIRE PTY LIMITED (ACN 089 243 989)
STANDARD TERMS AND CONDITIONS OF SALE
RIGHTS IN RELATION TO GOODS
INTERPRETATION 18 Seller reserves the following rights in relation to the goods until all accounts owed by the Buyer to the Seller are fully paid:
1 In these conditions: 18.1 legal ownership of the goods;
1.1 ‘Buyer’ means the buyer of any goods including any specified overleaf. 18.2 to enter the Buyer’s premises (or the premises of any associated company or agent where the goods are located) without liability for trespass or
1.2 ‘Conditions’ or ‘these conditions’ means these Terms and Conditions of Sale. any resulting damage and retake possession of the goods irrespective of the manner of their attachment to any realty; and
1.3 ‘Costs’ includes Goods and Services Tax (GST) payable as a result of any taxable supply (including the release of any obligation arising under 18.3 to keep or resell any goods repossessed pursuant to (2) above.
these conditions by the Seller to the Buyer) or as a result of an order made in any proceedings between the Seller and the Buyer. TITLE TO GOODS
1.4 ‘Goods’ means any products and services specified including any overleaf. 19 Property in each unit of the goods shall remain with Seller until all monies owing to Seller on any account whatsoever have been paid (“the Debts”). The
1.5 ‘Seller’ means INCITE FIRE Pty Limited (ACN 089 243 989) and its assigns or successors and each corporation (within the meaning of that term in Buyer shall in the meantime take custody of the goods and retain them as Seller’s trustee, fiduciary agent and bailee and shall store the goods in such a
Section 9 of the Corporations Law) which now or hereafter is or shall be deemed to be related to manner that they are readily distinguishable from other goods owned by the Buyer or other persons (“the Other Goods”). Pending resale or utilisation in any
the Seller (within the meaning of Section 50 of the Corporations Law). manufacturing or other process, the goods are to be kept separate from the Other Goods and properly marked, stored, protected and insured.
1.6 Nothing in these conditions shall be read or applied so as to exclude, restrict or modify or have the effect of excluding, restricting or modifying 19.1 The Buyer may resell the goods, but only as fiduciary agent and trustee for the Seller, by way of bona fide sale at full market value and in the
any condition, warranty, guarantee, right or remedy implied by law (including the Trade Practices Act 1974) and which by law cannot be ordinary course of its business.
excluded, restricted or modified. 19.2 Until the Debts have been paid in full the Buyer shall hold such part of the money it receives from:-
GENERAL 19.2.1 any sub-sale of the goods under the immediately preceding subclause; and
2 These conditions (which shall only be waived or varied in writing signed by the Seller) shall prevail over all conditions of the Buyer’s order to the extent of 19.2.2 the proceeds of any sale of any products into which the goods have been mixed or converted by any process as equals the amount of the
any inconsistency. debts at the time the money is received (“the Proceeds”) as bailee and fiduciary agent and trustee for the Seller.
TERMS OF SALE 19.3 The Buyer expressly acknowledges that it is bound by such fiduciary obligation and acknowledges that:
3 The goods and all other products sold by the Seller are sold on these terms and conditions. 19.3.1 it must hold the Proceeds on trust for the Seller.
4 Where any payment from the Buyer to the Seller is overdue the Seller may without notice demand from the Buyer payment of all amounts due for any 19.3.2 it must place the whole of the Proceeds in an account separate from its own moneys (“the Proceeds Account”).
goods sold by the Seller to the Buyer. 19.3.3 it must maintain the Proceeds Account separate from its own moneys at all times.
SAMPLES, VARIANCES, ETC 19.3.4 it must maintain proper records for the Proceeds Account.
5 All samples, specifications, drawings, and particulars of dimensions, gauge, shade, colour or quality submitted to the Seller are approximate only and any 19.3.5 it must not assign or encumber the Proceeds or do any other act in derogation of the Seller’s legal or beneficial interests.
deviation shall not be taken to vitiate any contract with the Seller or form grounds for any claim against the Seller. 19.3.6 it must account to the Seller on demand for all moneys standing to the credit of such account;
DELIVERY 19.3.7 the Seller may appropriate payments to such goods and accounts as it thinks fit, notwithstanding any contrary appropriation by the Buyer;
6 Where the Seller arranges delivery it is as agent of the Buyer and at the Buyer’s risk and in that circumstance the sale is to be treated as if it had been made 19.3.8 for the purposes of identification of different consignments of goods purchased from Seller and receipt of Proceeds, the Buyer agrees that the
at the Seller’s premises. principle of “Last In, First Out” shall be applied to any items which cannot be distinguished.
7 The delivery times made known to the Buyer are estimates only and Seller shall not be liable for to late delivery or non-delivery and under no circumstances 19.3.9 receipt by the Buyer of payment for the sale of any products into which the goods have been mixed or converted by any process shall be
shall the Seller be liable for any loss, damage or delay occasioned to the Buyer or its customers arising from late or non-delivery of the goods. treated as evidence that it has received Proceeds; and
LOSS OR DAMAGE IN TRANSIT 19.3.10 the Seller may trace the Proceeds in equity.
8 The Seller is not responsible for any loss or damage to goods in transit. BUYER’S PROPERTY
SELLER’S LIABILITIES 20 Any property of the Buyer under the Seller’s custody or control shall be entirely at the Buyer’s risk as regards loss or damage caused to the property or by it.
9 The Seller shall not be liable for and the Buyer releases the Seller from any claims in respect of faulty or defective design of any goods supplied unless such The Buyer expressly grants to the Seller such rights of sale as would arise if the Seller had displayed a notice under the Disposal of Uncollected Goods Act,
design has been wholly prepared by the Seller and the responsibility for any claim has been specifically accepted by the Seller in writing and in any event whether or not the Seller had displayed such a notice.
the Seller’s liability hereunder shall be strictly limited to the replacement of defective goods in accordance with these conditions. STORAGE
10 Except as provided in these conditions, all express and implied warranties, guarantees and conditions under statute or general law as to merchantability, 21 The Seller reserves the right to make a reasonable charge for storage if delivery instructions are not provided by the Buyer within fourteen days after a
description, quality, suitability or fitness of the goods for any purpose or as to design, assembly, installation, materials or workmanship or otherwise are hereby request by the Seller for such information.
expressly excluded. The Seller shall not be liable for physical or financial injury, loss or damage or for consequential loss or damage of any kind arising out of GOODS SOLD
the supply, layout, assembly, installation, materials or workmanship or otherwise are hereby expressly excluded and the Seller shall not be liable for physical 22 All goods to be supplied by Seller shall be as described on the purchase order agreed by the Seller and the Buyer and the description on such purchase
or financial injury, loss or damage or for consequential loss or damage of any kind arising out of the supply, layout, assembly, installation or operation of the order modified as so agreed shall prevail over all other descriptions including any Buyer’s specification or enquiry. The goods supplied are not designed or
goods or arising out of the Seller’s negligence or in any way whatsoever. adapted for use in adverse industrial atmosphere or weather or abnormal operating conditions of any kind.
11 The Buyer acknowledges its duty to inspect the entire order to ensure its satisfaction with the order. CANCELLATION
12 The Seller’s liability for a breach of a condition or warranty implied by Division 2 of Pt V of the Trade Practices Act 1974 (other than s 69) is hereby limited to:- 23 No order may be cancelled except with consent in writing and on terms which will indemnify the Seller against all losses.
12.1 in the case of goods, any one or more of the following: PLACE OF CONTRACT
12.1.1 the replacement of the goods or the supply of equivalent goods; 24 The contract for the sale of the goods is made in the state inwhich the sale originates and the parties agree to submit all disputes arising between them to
12.1.2 the repair of the goods; the courts of such state at any court competent to hear appeals therefrom.
12.1.3 the payment of the cost of replacing the goods or of acquiring equivalent goods; NO WAIVER
12.1.4 the payment of the cost of having the goods repaired; or 25 The failure of any party to enforce the provisions of this agreement or to exercise any rights expressed in this agreement shall not be a waiver of such
12.2 in the case of services: provisions or rights and shall not affect the enforcement of this agreement. The exercise by any party of any of its rights expressed in this agreement shall not
12.2.1 the supplying of the services again; or preclude or prejudice such party from exercising the same or any other rights it may have irrespective of any previous action taken by that party.
12.2.2 the payment of the cost of having the services supplied again. FORCE MAJEURE
12.3 The Seller’s liability under s 74H of the Trade Practices Act 1975 is expressly limited to a liability to pay to the Buyer an amount equal to: 26 Where a party is unable, wholly or in part, by reason of an act of God, strike, lockout or other interference with work, war declared or undeclared,
12.3.1 the cost of replacing the goods; blockade, disturbance, lightning, fire, earthquake, storm, flood, explosion, governmental or quasi-governmental restraint, expropriation prohibition
12.3.2 the cost of obtaining equivalent goods; or intervention direct or embargo, unavailability or delay in availability of equipment or transport, inability or delay in obtaining governmental or quasi-gover
12.3.3 the cost of having the goods repaired, whichever is the lowest amount. mental approvals consents permits licences authorities or allocations, and any other cause whether of the kind specifically enumerated above or otherwise
PRICES which is not reasonably within the control of the party affect (`force majeure’), to carry out any obligation under this agreement and that party:
13 Unless otherwise stated all prices quoted by the Seller are exclusive of GST. Prices quoted are those ruling at the date of issue of quotation and are based 26.1 gives the other party prompt notice of that force majeure with reasonably full particulars thereof, and, insofar as known, the probable extent of
on rates of freight, insurance, customs duties, currency exchange, shipping expenses, sorting and stacking charges, cartage, rates of weights, cost of which it will be unable to perform or be delayed in performing that obligation; and
materials and other charges affecting the cost of supply ruling on the date the quotation is made and any alterations thereto either before acceptance of 26.2 uses all possible diligence to remove that force majeure as quickly as possible; that obligation is suspended so far as it is affected by force
or during the currency of the contract shall be to the Buyer’s account. Where no prices have been quoted by the Seller, the price to be charged is that majeure during the continuance thereof provided that;
ruling on the date of delivery of the goods. The Seller is at liberty to change its prices without notice to the Buyer. 26.3 an obligation to pay money is never excused by force majeure.
PAYMENT 26.4 the requirement that any force majeure shall be removed with all possible diligence shall not require the settlement of strikes, lockouts or other
14 The Buyer must pay the net invoice amount together with all Costs to the Seller at its address for payment, without demand, within 30 days after delivery of labour disputes, or claims or demands by any government on terms contrary to the wishes of the party affected.
the goods in respect of which an invoice was raised by the Seller. EXCLUSION OF NEGLIGENCE
15 By way of liquidated damages for breach of the payment obligation in these conditions, the Buyer agrees to pay compound interest on the net invoice 27 The Seller shall not be liable to the Buyer in contract or in tort arising out of, or in connection with, or relating to, the performance of the goods or any such
amount and all Costs calculated from the date of invoice at the rates set from time to time by section 94 of the Supreme Court Act, 1970 plus 1/8th of that rate. breach of these conditions or of any fact, matter or thing relating to the goods or error (whether negligent of a breach of contract or not) in information
16 Where the Buyer pays the purchase price in accordance with these conditions the Seller accepts that sum in full satisfaction of the Buyer’s obligation. supplied to the Buyer or a user before or after the date of the Buyer’s or user’s use of the goods.
The Buyer acknowledges that only payments which reach the Seller at its stated address for payment within the month following the month in which the SEVERANCE
goods were delivered or such other terms of payment specified in writing by the Seller shall be entitled to receive the benefit of this concession. 28 If any of the terms or conditions is deemed to be unlawful or unenforceable, such term or condition shall be severed and all other terms and conditions shall
17 The Buyer agrees to pay the Seller’s legal costs as between solicitor and own client for all legal actions between the Seller and the Buyer in regard to the remain in force.
failure of the Buyer to comply with these conditions.
www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
INCITE FIRE PTY LIMITED (ACN 089 243 989)
STANDARD TERMS AND CONDITIONS OF SALE
RIGHTS IN RELATION TO GOODS
INTERPRETATION 18 Seller reserves the following rights in relation to the goods until all accounts owed by the Buyer to the Seller are fully paid:
1 In these conditions: 18.1 legal ownership of the goods;
1.1 ‘Buyer’ means the buyer of any goods including any specified overleaf. 18.2 to enter the Buyer’s premises (or the premises of any associated company or agent where the goods are located) without liability for trespass or
1.2 ‘Conditions’ or ‘these conditions’ means these Terms and Conditions of Sale. any resulting damage and retake possession of the goods irrespective of the manner of their attachment to any realty; and
1.3 ‘Costs’ includes Goods and Services Tax (GST) payable as a result of any taxable supply (including the release of any obligation arising under 18.3 to keep or resell any goods repossessed pursuant to (2) above.
these conditions by the Seller to the Buyer) or as a result of an order made in any proceedings between the Seller and the Buyer. TITLE TO GOODS
1.4 ‘Goods’ means any products and services specified including any overleaf. 19 Property in each unit of the goods shall remain with Seller until all monies owing to Seller on any account whatsoever have been paid (“the Debts”). The
1.5 ‘Seller’ means INCITE FIRE Pty Limited (ACN 089 243 989) and its assigns or successors and each corporation (within the meaning of that term in Buyer shall in the meantime take custody of the goods and retain them as Seller’s trustee, fiduciary agent and bailee and shall store the goods in such a
Section 9 of the Corporations Law) which now or hereafter is or shall be deemed to be related to manner that they are readily distinguishable from other goods owned by the Buyer or other persons (“the Other Goods”). Pending resale or utilisation in any
the Seller (within the meaning of Section 50 of the Corporations Law). manufacturing or other process, the goods are to be kept separate from the Other Goods and properly marked, stored, protected and insured.
1.6 Nothing in these conditions shall be read or applied so as to exclude, restrict or modify or have the effect of excluding, restricting or modifying 19.1 The Buyer may resell the goods, but only as fiduciary agent and trustee for the Seller, by way of bona fide sale at full market value and in the
any condition, warranty, guarantee, right or remedy implied by law (including the Trade Practices Act 1974) and which by law cannot be ordinary course of its business.
excluded, restricted or modified. 19.2 Until the Debts have been paid in full the Buyer shall hold such part of the money it receives from:-
GENERAL 19.2.1 any sub-sale of the goods under the immediately preceding subclause; and
2 These conditions (which shall only be waived or varied in writing signed by the Seller) shall prevail over all conditions of the Buyer’s order to the extent of 19.2.2 the proceeds of any sale of any products into which the goods have been mixed or converted by any process as equals the amount of the
any inconsistency. debts at the time the money is received (“the Proceeds”) as bailee and fiduciary agent and trustee for the Seller.
TERMS OF SALE 19.3 The Buyer expressly acknowledges that it is bound by such fiduciary obligation and acknowledges that:
3 The goods and all other products sold by the Seller are sold on these terms and conditions. 19.3.1 it must hold the Proceeds on trust for the Seller.
4 Where any payment from the Buyer to the Seller is overdue the Seller may without notice demand from the Buyer payment of all amounts due for any 19.3.2 it must place the whole of the Proceeds in an account separate from its own moneys (“the Proceeds Account”).
goods sold by the Seller to the Buyer. 19.3.3 it must maintain the Proceeds Account separate from its own moneys at all times.
SAMPLES, VARIANCES, ETC 19.3.4 it must maintain proper records for the Proceeds Account.
5 All samples, specifications, drawings, and particulars of dimensions, gauge, shade, colour or quality submitted to the Seller are approximate only and any 19.3.5 it must not assign or encumber the Proceeds or do any other act in derogation of the Seller’s legal or beneficial interests.
deviation shall not be taken to vitiate any contract with the Seller or form grounds for any claim against the Seller. 19.3.6 it must account to the Seller on demand for all moneys standing to the credit of such account;
DELIVERY 19.3.7 the Seller may appropriate payments to such goods and accounts as it thinks fit, notwithstanding any contrary appropriation by the Buyer;
6 Where the Seller arranges delivery it is as agent of the Buyer and at the Buyer’s risk and in that circumstance the sale is to be treated as if it had been made 19.3.8 for the purposes of identification of different consignments of goods purchased from Seller and receipt of Proceeds, the Buyer agrees that the
at the Seller’s premises. principle of “Last In, First Out” shall be applied to any items which cannot be distinguished.
7 The delivery times made known to the Buyer are estimates only and Seller shall not be liable for to late delivery or non-delivery and under no circumstances 19.3.9 receipt by the Buyer of payment for the sale of any products into which the goods have been mixed or converted by any process shall be
shall the Seller be liable for any loss, damage or delay occasioned to the Buyer or its customers arising from late or non-delivery of the goods. treated as evidence that it has received Proceeds; and
LOSS OR DAMAGE IN TRANSIT 19.3.10 the Seller may trace the Proceeds in equity.
8 The Seller is not responsible for any loss or damage to goods in transit. BUYER’S PROPERTY
SELLER’S LIABILITIES 20 Any property of the Buyer under the Seller’s custody or control shall be entirely at the Buyer’s risk as regards loss or damage caused to the property or by it.
9 The Seller shall not be liable for and the Buyer releases the Seller from any claims in respect of faulty or defective design of any goods supplied unless such The Buyer expressly grants to the Seller such rights of sale as would arise if the Seller had displayed a notice under the Disposal of Uncollected Goods Act,
design has been wholly prepared by the Seller and the responsibility for any claim has been specifically accepted by the Seller in writing and in any event whether or not the Seller had displayed such a notice.
the Seller’s liability hereunder shall be strictly limited to the replacement of defective goods in accordance with these conditions. STORAGE
10 Except as provided in these conditions, all express and implied warranties, guarantees and conditions under statute or general law as to merchantability, 21 The Seller reserves the right to make a reasonable charge for storage if delivery instructions are not provided by the Buyer within fourteen days after a
description, quality, suitability or fitness of the goods for any purpose or as to design, assembly, installation, materials or workmanship or otherwise are hereby request by the Seller for such information.
expressly excluded. The Seller shall not be liable for physical or financial injury, loss or damage or for consequential loss or damage of any kind arising out of GOODS SOLD
the supply, layout, assembly, installation, materials or workmanship or otherwise are hereby expressly excluded and the Seller shall not be liable for physical 22 All goods to be supplied by Seller shall be as described on the purchase order agreed by the Seller and the Buyer and the description on such purchase
or financial injury, loss or damage or for consequential loss or damage of any kind arising out of the supply, layout, assembly, installation or operation of the order modified as so agreed shall prevail over all other descriptions including any Buyer’s specification or enquiry. The goods supplied are not designed or
goods or arising out of the Seller’s negligence or in any way whatsoever. adapted for use in adverse industrial atmosphere or weather or abnormal operating conditions of any kind.
11 The Buyer acknowledges its duty to inspect the entire order to ensure its satisfaction with the order. CANCELLATION
12 The Seller’s liability for a breach of a condition or warranty implied by Division 2 of Pt V of the Trade Practices Act 1974 (other than s 69) is hereby limited to:- 23 No order may be cancelled except with consent in writing and on terms which will indemnify the Seller against all losses.
12.1 in the case of goods, any one or more of the following: PLACE OF CONTRACT
12.1.1 the replacement of the goods or the supply of equivalent goods; 24 The contract for the sale of the goods is made in the state inwhich the sale originates and the parties agree to submit all disputes arising between them to
12.1.2 the repair of the goods; the courts of such state at any court competent to hear appeals therefrom.
12.1.3 the payment of the cost of replacing the goods or of acquiring equivalent goods; NO WAIVER
12.1.4 the payment of the cost of having the goods repaired; or 25 The failure of any party to enforce the provisions of this agreement or to exercise any rights expressed in this agreement shall not be a waiver of such
12.2 in the case of services: provisions or rights and shall not affect the enforcement of this agreement. The exercise by any party of any of its rights expressed in this agreement shall not
12.2.1 the supplying of the services again; or preclude or prejudice such party from exercising the same or any other rights it may have irrespective of any previous action taken by that party.
12.2.2 the payment of the cost of having the services supplied again. FORCE MAJEURE
12.3 The Seller’s liability under s 74H of the Trade Practices Act 1975 is expressly limited to a liability to pay to the Buyer an amount equal to: 26 Where a party is unable, wholly or in part, by reason of an act of God, strike, lockout or other interference with work, war declared or undeclared,
12.3.1 the cost of replacing the goods; blockade, disturbance, lightning, fire, earthquake, storm, flood, explosion, governmental or quasi-governmental restraint, expropriation prohibition
12.3.2 the cost of obtaining equivalent goods; or intervention direct or embargo, unavailability or delay in availability of equipment or transport, inability or delay in obtaining governmental or quasi-gover
12.3.3 the cost of having the goods repaired, whichever is the lowest amount. mental approvals consents permits licences authorities or allocations, and any other cause whether of the kind specifically enumerated above or otherwise
PRICES which is not reasonably within the control of the party affect (`force majeure’), to carry out any obligation under this agreement and that party:
13 Unless otherwise stated all prices quoted by the Seller are exclusive of GST. Prices quoted are those ruling at the date of issue of quotation and are based 26.1 gives the other party prompt notice of that force majeure with reasonably full particulars thereof, and, insofar as known, the probable extent of
on rates of freight, insurance, customs duties, currency exchange, shipping expenses, sorting and stacking charges, cartage, rates of weights, cost of which it will be unable to perform or be delayed in performing that obligation; and
materials and other charges affecting the cost of supply ruling on the date the quotation is made and any alterations thereto either before acceptance of 26.2 uses all possible diligence to remove that force majeure as quickly as possible; that obligation is suspended so far as it is affected by force
or during the currency of the contract shall be to the Buyer’s account. Where no prices have been quoted by the Seller, the price to be charged is that majeure during the continuance thereof provided that;
ruling on the date of delivery of the goods. The Seller is at liberty to change its prices without notice to the Buyer. 26.3 an obligation to pay money is never excused by force majeure.
PAYMENT 26.4 the requirement that any force majeure shall be removed with all possible diligence shall not require the settlement of strikes, lockouts or other
14 The Buyer must pay the net invoice amount together with all Costs to the Seller at its address for payment, without demand, within 30 days after delivery of labour disputes, or claims or demands by any government on terms contrary to the wishes of the party affected.
the goods in respect of which an invoice was raised by the Seller. EXCLUSION OF NEGLIGENCE
15 By way of liquidated damages for breach of the payment obligation in these conditions, the Buyer agrees to pay compound interest on the net invoice 27 The Seller shall not be liable to the Buyer in contract or in tort arising out of, or in connection with, or relating to, the performance of the goods or any such
amount and all Costs calculated from the date of invoice at the rates set from time to time by section 94 of the Supreme Court Act, 1970 plus 1/8th of that rate. breach of these conditions or of any fact, matter or thing relating to the goods or error (whether negligent of a breach of contract or not) in information
16 Where the Buyer pays the purchase price in accordance with these conditions the Seller accepts that sum in full satisfaction of the Buyer’s obligation. supplied to the Buyer or a user before or after the date of the Buyer’s or user’s use of the goods.
The Buyer acknowledges that only payments which reach the Seller at its stated address for payment within the month following the month in which the SEVERANCE
goods were delivered or such other terms of payment specified in writing by the Seller shall be entitled to receive the benefit of this concession. 28 If any of the terms or conditions is deemed to be unlawful or unenforceable, such term or condition shall be severed and all other terms and conditions shall
17 The Buyer agrees to pay the Seller’s legal costs as between solicitor and own client for all legal actions between the Seller and the Buyer in regard to the remain in force.
failure of the Buyer to comply with these conditions.
www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
vesda
®
Catalogue Disclaimer
1.1 The information contained in this catalogue is obtained from the various manufacturers of the products. We are merely passing the information to you.
We do not guarantee that the information is correct. Prior to making a decision to purchase you should confirm the details of the product with an
alternative source directly.
1.2 Product descriptions and specifications are subject to change at any time, without notice.
1.3 We do not guarantee that any particular product will be available for sale. The availability for sale of the products described in this catalogue depends on
the manufacturer and is beyond our control. This catalogue is not an offer of sale.
YBF-RL/2NBF
Analogue
Previous
Our Objective
Bases
“Quality fire detection and warning equipment,
independently supplied & supported”
YBN-R/2NA
YBO-R/SCI
Analogue
Bases
New
Conventional Fire Detection
We stock the complete range of current & past model Hochiki detectors, as well as a
selection of conventional panels which can be customised to suit your requirements.
Addressable
YBF-RL/3JM
AMU-MBM
AMU-B2M
Previous
Incite Fire is the NSW & ACT distributor of the FireNet analogue panel. We also stock the
Bases
complete range of Hochiki addressable detectors & field modules.
VESDA
Incite Fire is an authorised distributor for the complete range of VESDA aspirated detectors
YCA-RL/3H2M
YBF-RL/4AHAM YCA-RL/5H2M
as well as pipework & fittings. Spare parts are available & we can also arrange for
Addressable
the repair of all current model detectors.
Bases
New
Warning Systems
A range of OWS and accessories to suit your requirements, as well as EWIS panels
configurable to suit any site specifications.
Conventional Conventional
YBC-R/3A
Ancillary Equipment
Previous
Bases
A comprehensive range of ancillary devices including KAC manual call points, a selection
of speakers, sounders & strobes. We also stock a range of magnetic door retainers to suit
many different applications including the new brass & chrome finish door holders for a
more prestigious application.
YBO-R/4A
Special Applications
Bases
New
A selection of detection equipment for special applications including flame detectors,
firewire, VESDA. Also available is intrinsically safe equipment & detectors suitable
for marine applications.
Miscellaneous
SIH-AM – Ionization
AIE-AS – Ionization
ATG-AS – Thermal
AIA-E – Ionization
• Hochiki - Detectors Analogue & Conventional
ATA-E –Thermal
• VESDA - Range of Aspirated Detectors
• Simplex - Evacuation & Warning Systems
For further information
Call: 1300 INCITE (462483)
Or visit us at: www.incitefire.com.au
www.incitefire.com.au • For customer service call 1300 INCITE www.incitefire.com.au • For customer service call 1300 INCITE
“Quality fire detection and warning equipment,
independently supplied and supported”
Contact details
NSW/ACT VIC EMAIL
3/165 Rookwood Road
Yagoona NSW 2199
Axxess Corporate Park
120/45 Gilby Road
sales@incitefire.com.au
accounts@incitefire.com.au 1300 INCITE
Tel: 1300 INCITE Mount Waverley VIC info@incitefire.com.au
Fax: 02 9707 1900 Tel: 1300 INCITE