HCFC-Free Ultra-Low Temperature Chest Freezers


Specifications
For MDF-1156/1156ATN Advanced Features Model No. MDF-1156/1156ATN MDF-793/793AT MDF-593/593AT MDF-393/393AT MDF-192/192AT
Temperature Range –125˚C to –152˚C –20˚C to –86˚C
Why Freeze to –152˚C? Specially designed compressor Self-diagnostic function
Exterior Dimensions 1,400 x 800 x 945 2,570 x 770 x 1,070 2,010 x 770 x 1,070 1,860 x 800 x 945 750 x 700 x 945
Recrystallization Mechanism (Artist’s Concept) and cascade refrigeration system The temperature sensor, filter sen- [W x D x H] mm (inch) (55.1 x 31.5 x 37.2) (101.2 x 30.3 x 42.1) (79.1 x 30.3 x 42.1) (73.2 x 31.5 x 37.2) (29.5 x 27.6 x 37.2)

Hexagonal crystal
Designed by sor and cascade sensor monitor op- Interior Dimensions 500 x 450 x 572 1,840 x 500 x 762 1,280 x 500 x 762 1,120 x 520 x 530 480 x 430 x 420
eration conditions continuously. [W x D x H] mm (inch) (19.7 x 17.7 x 22.5) (72.4 x 19.7 x 30) (50.3 x 19.7 x 30) (44.1 x 20.5 x 20.9) (18.9 x 16.9 x 16.5)
–80˚C SANYO specifi-
Effective Capacity 128 liters (4.5 cu.ft.) 701 liters (24.7 cu.ft.) 487 liters (17.1 cu.ft.) 309 liters (10.9 cu.ft.) 86 liters (3.0 cu.ft.)
cally for rugged Should abnormality be picked up,
Cubic crystal Exterior Cabinet Painted steel
an error code and the current tem-
–130˚C
ultra-low temper-
ature applications perature will be displayed in turn.
Interior Cabinet
Inner Lid
Aluminum plate
1 4
Stainless steel
3 1 HCFC-Free
in a laboratory Insulation Rigid polyurethane foamed-in place
Recrystallization point
–152˚C
Amorphous
ice crystal environment
Ring back function
The alarm buzzer can be silenced
Compressor
High stage side
Low stage side
Hermetic type, 1,100 W
Hermetic type, 1,100 W
Hermetic type, 1,100 W
Hermetic type, 1,100 W
Hermetic type, 750 W
Hermetic type, 750 W
Hermetic type, 400 W
Hermetic type, 400 W
Hermetic reciprocated type,
400 W
Ultra-Low Temperature
(HFC refrigerants
only).
by pressing the BUZZER key on the
control panel. (The remote alarm
Evaporator
High stage side
Low stage side
Cascade condenser
Tube on sheet (shared with interior)
Tube-on-sheet type Chest Freezers
High stage side Fin and tube type Fin and tube type
World’s lowest –152˚C freezer Micro-processor Temperature signal is not cancelled.) Should the Condenser Fin and tube type
Low stage side Cascade condenser Shell and tube type
ensures stable cell and tissue Control with LED Digital Display alarm condition continue after a Microprocessor Microprocessor: Keypad input
preservation certain suspension, the alarm buzz- Temperature Control control system, Temp. input range: –20˚C to –95˚C (1˚C increment)
Extremely accurate, easy-to-read Non-volatile memory Set value memory: non-volatile memory
An important factor to consider display. The temperature inside the er sound will resume. Temperature Display Digital display
when preserving cells or tissue at freezer can be set and monitored Sensor Platinum resistance (Pt. 100 Ω)
Filter check lamp
ultra-low temperatures is to pre- easily by means of a microproces- Alarm system Selectable high temp. alarm (+10˚C & +15˚C from set point), Power failure alarm, Filter check lamp, Remote alarm contact
and easy-to-
vent amorphous ice crystals from sor temperature control with an Net Weight (Approx.)
265 kg (584 lbs.) —1156 365 kg (805 lbs.) —793 305 kg (672 lbs.) —593 248 kg (547 lbs.) —393 121 kg (267 lbs.) —192
clean, front-acces- 272 kg (600 lbs.) —1156ATN 375 kg (827 lbs.) —793AT 315 kg (694 lbs.) —593AT 255 kg (562 lbs.) —393AT 127 kg (280 lbs.) —192AT
recrystallizing within and outside LED digital display. The thermostat sible air filter ATN: LN2 backup system, temperature recorder
the cells. Samples that are main- incorporates a platinum resistor AT: LCO2 backup system, temperature recorder
(Except MDF-192)
tained in an ultra-low temperature (Pt. 100Ω), precision and durability. Optional Accessories
freezer at –152˚C which is far lower Note: The position of the filter check lamp is shown
than the recrystallization point Integrated Cabinet Design on the control panel (see photo below).
Storage Racks (Aluminium) Temperature Recorder
Model No. MDF-19SC MDF-39SC MDF-49SC MDF-59SC Model No. MTR-85H MTR-155H
(–130˚C for pure water) can be pre- High-performance refrigeration sys-
tem with foamed-in-place cabinet Standard casters and levelling feet Case Dimensions 207 x 144 x 413mm 155 x 155 x 515mm 207 x 144 x 539mm 207 x 144 x 665mm Recording
served semi-permanently. Preser- (W x D x H) 8.1” x 5.7” x 16.3” 6.1” x 6.1” x 20.3” 8.1” x 5.7” x 21.2” 8.1” x 5.7” x 26.2” Range
–100 to +50˚C –170 to +30˚C
vation at ultra-low temperatures insulation maximizes interior tem- Standard-equipped heavy duty cas- Number of Drawers 3 4 4 5 MDF-192
maintains vitrification without perature uniformity and protects ters make it easy to move a freezer Applicable Model MDF-593/593AT (18)
Freezer MDF-393 MDF-1156

–86˚C
MDF-192/192AT (6) MDF-393/393AT (20) MDF-1156/1156ATN (6) Model MDF-593
crystallization occurring inside and against fluctuating ambient temper- when necessary. The levelling feet (Rack capacity) MDF-793/793AT (24) MDF-793
outside cells. atures. keep a freezer level and firm on the Inventory Racks (Stainless steel) ULT-Freezer Backup Kits
In contrast to conventional liquid floor. Box Type External Dimensions (mm)
Hot line for secure sealing Model No. Freezer Model (Rack capacity) CVK-UB2/UB2(I):

–86˚C
nitrogen preservation containers, (Capacity) Width Depth Height
LCO2 Backup Kit for MDF-793/593/393
Moisture condensation at the top Safety Device
freezer preservation has numerous IR-207C 2” (7) 144 142 405 MDF-192 (6) CVK-UBN2/UBN2(I):
edges of the cabinet due to differ- LN2 Backup Kit for MDF-793/593/393
advantages: no sample contamina- Built-In Temperature & Power IR-209C 2” (9) 144 142 518 MDF-393 (21), 1156 (9)
ences in temperature inside and CVK-A: Built-in LCO2 Backup Kit
tion, no sudden liquid eruptions, as Failure Alarms (Lamp/Buzzer) IR-213C 2” (13) 144 142 592 MDF-593 (24), 793 (36)
for MDF-793/593/393/192
out causes frost and icing problems
well as low operational costs. In case of power failure or an irreg-
IR-305C 3” (5) 144 142 405 MDF-192 (6) CVK-AT2: LCO2 Backup Kit for MDF-1156
that may reduce heat insulation
SANYO’s MDF-1156 and 1156ATN ular rise in temperature, a recharge-
IR-306C 3” (6) 144 142 518 MDF-393 (21), 1156 (9) CVK-ATN2: LN2 Backup Kit for MDF-1156
efficiency and obstruct door move-
make long-term storage below the able battery-operated indicator
IR-309C 3” (9) 144 142 747 MDF-593 (24), 793 (36) IR-209C IR-306C MDF-39SC MDF-59SC
(I) version for North America only
ments. These problems are preven-
recrystallization point easier and lamp and alarm will be activated. A
ted by the “hot line” by means of *Appearance and specifications are subject to change without notice.
more stable than ever before. compact recording unit which auto- *Cooling performance is indicated by the temperature reached at the center of the freezer (at ambient temperature of 30°C with no load).
which hot gas In order to use the freezer at a stable temperature for a long time, it is recommended that the temperature be set to at least 5°C higher
from the higher matically records the inside temper- than the indicated lowest temperature.
In addition, depending on the usage conditions, it may not be possible to reach the indicated lowest temperature.
temperature ature, and a backup system with
circuit is circu- liquefied CO2 or N2 which is self-
lated through activated when a power outage
the problem occurs are also available separately.
areas. This equipment helps insure that
Hot line
the contents will be protected in
the event of any power failure or MDF-593AT
Control panel
1 Alarm lamp and buzzer mechanical trouble. MDF-192
2 Filter check lamp We design and manufacture products in accordance with ISO9001 & 14001 requirements.
3 Buzzer key
1
4 Alarm test key

–152˚C
2 Distributed by:
5 Mode setting key
6 MDF-1156ATN
Digit shift key
3 4 5 6 7 8 7 Numerical value shift key
8 Enter key
10 12 9 Power switch
10 CO2 Back-up test swich (AT type only) SANYO Electric Co., Ltd.
9 11 13
14 11 CO2 Back-up swich (AT type only) SANYO Sales & Marketing Corporation
5-15, Hiyoshi-cho 2-chome, Moriguchi City, Osaka, 570-8634, Japan
12 Battery switch Telephone: +81-6-6992-0322 Fax: +81-6-6992-9291
13 Remote alarm switch URL http://www.sanyo.co.jp/cmg/biomedical
MDF-393AT 14 Temperature recorder ©2006 SANYO Printed in Japan 2006.7. MA. SHR095
0606-V1797-05-0706-M02-05-pdf 06.7.6 11:14 ページ 2

The Ideal –152˚C, –86˚C Freezing Environment –86˚C Ultra-Low Temperature Chest Freezers
in Capacities from 86 L to 701 L Ideal for large-capacity preservation
Low-profile design for easy access
to stored materials
Ideal for long term preservation of biologicals, blood components and various
cell line, SANYO preservation systems employ microprocessor control to
MDF-793/793AT MDF-393/393AT
TEMPERATURE EFFECTIVE CAPACITY TEMPERATURE EFFECTIVE CAPACITY
maintain a high-precision temperature environment. They are not affected by
ambient temperature, minimizing uneven temperature distribution within the
chamber, and a temperature rise during door opening.
–86˚C 701 L (24.7 cu.ft. ) –86˚C 309 L (10.9 cu.ft. )
Dimensions Unit: mm (inch) 861 (33.9) Dimensions Unit: mm (inch) 891 (35.1)
2570 (101.2) 770 (30.3) 1860 (73.2) 800 (31.5)
53 38 53 38 (1.5)

–152˚C Ultra-Low Temperature Chest Freezer 2110 (83.1) (2.1) (1.5)


MDF-793AT 1400 (55.1) (2.1)

530 (20.9)
MDF-393

1070 (42.1)

945 (37.2)
762 (30)
795 (31.3)

660 (26.0)
1120 (44.1)
1840 (72.4) 520 (20.5)
500 (19.7)

105 (4.1) 105 (4.1)

Performance Data Performance Data


For stable long-term storage Pull-down characteristics Pull-up characteristics Effect of ambient temp. Pull-down characteristics Pull-up characteristics Effect of ambient temp.
under no-load condition during power failure on holding time of liquefied gas under no-load condition during power failure on holding time of liquefied gas
MDF-1156/1156ATN 30
20
10
Central air temp. in cabinet
30
20
10
Central air temp. in cabinet
20
SV of backup system –70˚C
30
20
10 Central air temp. in cabinet
30
20
10
20
SV of backup system –70˚C
TEMPERATURE EFFECTIVE CAPACITY 0 Ambient temp. 30˚C, no load 0 Ambient temp. 30˚C, no load LCO2 30kg 0 Ambient temp. 30˚C, no load 0 LCO2 30kg

Temp. (˚C)

Temp. (˚C)

Temp. (˚C)

Temp. (˚C)
–10 –10 15 –10 –10 15

Time (hr.)

Time (hr.)
–152˚C 128 L (4.5 cu.ft. )
–20
–30
–40
–50
–60
–20
–30
–40
–50
–60
10
–20
–30
–40
–50
–60
–20
–30
–40
–50
–60
10
Central air temp. in cabinet
–70 –70 –70 –70
–80 –80 –80 –80 Ambient temp. 30˚C, no load
–90 –90 5 –90 –90 5
0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10 5 10 15 20 25 30 35 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10 5 10 15 20 25 30 35
Time (hr.) Time (hr.) Ambient temp. (˚C) Time (hr.) Time (hr.) Ambient temp. (˚C)

Compact, space-saving unit optimized


Dimensions Unit: mm (inch)
Ideal for middle-sized installation space for private use
905 (35.6)

1400 (55.1)
53
800 (31.5)
52
MDF-593/593AT MDF-192/192AT
(2.1) (2.0)
500 (19.7) 450 (17.7) TEMPERATURE EFFECTIVE CAPACITY TEMPERATURE EFFECTIVE CAPACITY

–86˚C 487 L (17.1 cu.ft. ) –86˚C 86 L (3.0 cu.ft. )


572 (22.5)

945 (37.2)
667 (26.3)

Dimensions Unit: mm (inch) 861 (33.9) Dimensions Unit: mm (inch)


791 (31.1)
105 2010 (79.1) 770 (30.3)
53 38 (1.5)
(4.1) (2.1) 750 (29.5) 700 (27.6)
1550 (61.0) 53 38 (1.5)
(2.1)
MDF-593AT

420 (16.5)
1070 (42.1)
762 (30)

945 (37.2)
MDF-192

795 (31.3)

658 (25.9)
1280 (50.4)
500 (19.7)
MDF-1156

105 (4.1) 480 (18.9) 430 (16.9)

Performance Data Performance Data Performance Data


Pull-down characteristics Pull-up characteristics Effect of ambient temp. Pull-down characteristics Pull-up characteristics Effect of ambient temp. Pull-down characteristics Pull-up characteristics Effect of ambient temp.
under no-load condition during power failure on holding time of liquefied gas under no-load condition during power failure on holding time of liquefied gas under no-load condition during power failure on holding time of liquefied gas
60 0 25 30 30 20 30 30 20
40 Central air temp. 20 Central air temp. in cabinet 20 Central air temp. in cabinet SV of backup system –70˚C 20 Central air temp. in cabinet 20
–20 LN2 injection at –135˚C 10 10 10 10
20 in cabinet Ambient temp. 30˚C, no load Ambient temp. 30˚C, no load LCO2 30kg Ambient temp. 30˚C, no load
0 –40 0 0 0
Ambient temp.

Time (hr.)
Temp. (˚C)

Temp. (˚C)

Temp. (˚C)

Temp. (˚C)

Temp. (˚C)

Temp. (˚C)
20 –10 –10 15 –10 –10 15
Time (hr.)

Time (hr.)
–20 30˚C, no load –60
–40 –20 –20 –20 –20
–80 –30 –30 –30 –30
–60 –40 –40 –40 –40
–80 –100 15 –50 –50 10 –50 –50 10
–100 –120 Central air temp. in cabinet SV of backup system –135˚C –60 –60 –60 –60
–120 –70 –70 –70 –70 Central air temp. in cabinet SV of backup system –70˚C
–140 –140 Ambient temp. 30˚C, no load LN2 50L –80 –80 –80 –80 Ambient temp. 30˚C, no load LCO2 30kg
–160 –160 0 –90 –90 5 –90 –90 5
0 5 10 15 20 25 0 1 2 3 4 5 6 7 8 9 0 10 20 30 40 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10 5 10 15 20 25 30 35 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10 5 10 15 20 25 30 35
Time (hr.) Time (hr.) Ambient temp. (˚C) Time (hr.) Time (hr.) Ambient temp. (˚C) Time (hr.) Time (hr.) Ambient temp. (˚C)

You might also like