Professional Documents
Culture Documents
Technical Details Relating To TMT Bars As Per BIS Specifications
Technical Details Relating To TMT Bars As Per BIS Specifications
ABOUT
JSW Neosteel- An Overview
Read about the best TMT Bars in the country that conform to Indian, American, British and Australian Standards.
Learn about what makes JSW Neosteel TMT Bars the preferred choice of millions of customers all over India
Landmark Projects
Discover some of the major projects that have been reinforced by JSW Neosteel TMT Bars
Read about the certifications received for JSW Neosteel and the results for various tests conducted on JSW Neosteel
PRODUCTS
JSW Neosteel 500 D
Read about our Super premium high strength and high ductility TMT re-bars
Read about our Ultra premium & ultra high strength TMT re-bars
BUY
Locate Distributor / Retailer
Consumer Price
TMT Calculator
BUILD
Home Owner Zone
Explore all the relevant information that you need to know to build your home
Engineer Zone
Explore a collection of all technical details you require while designing an RCC structure
Contractor Zone
FAQ
Contact
Locate JSW Steel Offices
Find the address and contact details for all our branches
https://www.jswneosteel.in/build/tmt-bars-bis-specifications.aspx 1/4
5/20/2018 Technical Details Relating To TMT Bars As Per BIS Specifications
Leave your message
and we will get back to you
Register as a Contractor
Fill in your details to become a JSW authorized contractor and experience a world of privileges
Fill in your details to become an authorized distributor/ retailer and become a part of the JSW family
Engineer Zone
Technical Details Relating To TMT Bars As Per BIS Specifications
Build Build
https://www.jswneosteel.in/build/tmt-bars-bis-specifications.aspx 2/4
5/20/2018 Technical Details Relating To TMT Bars As Per BIS Specifications
Reinforcing steel of same type and grade is to be used as main reinforcement in a structural member. However, simultaneous use of two different types or grades of
steel for main and secondary reinforcement respectively is permissible.
Bars may be arranged singly. or in pairs in contact, or in groups of three or four bars bundled in contact. Bundled bars shall be enclosed within stirrups or ties.
Bundled bars shall be tied together to ensure the bars remaining together. Bars larger than 32 mm diameter shall not be bundled. except in columns
The calculated tension or compression in any bar at any section shall be developed on each side of the section by an appropriate development length or end
anchorage or by a combination thereof.
Ld = φσs/4τbd
where
NOTES:
For deformed bars, conforming to IS 1786 these values shall be increased by 60 per cent.
For bars in compression, the values of bond stress for bars in tension shall be increased by 25 per cent.
Bars bundled in contact, The development length of each bar of bundled bars shall be that for the individual bar, increased by 0 percent for two bars in contact, 20
percent for three bars in contact and 33 percent for four bars in contact.
Deformed bars may be used without end anchorages provided development length requirement is satisfied. Hooks should normally he provided for plain bars
in tension.
Bends and hooks: Bends and hooks shall conform to IS 2502
Bends: The anchorage value of bend shall be taken as 4 times the diameter of the bar for each 45t' bend subject to a maximum of 16 times the diameter of the
bar.
Hooks: The anchorage value of a standard U-type hook shall be equal to J6 times the diamet.er of the bar.
The anchorage length of straight bar in compression shall be equal to the development length of bars in compression as specified in. The projected length of hooks,
bends and straight lengths beyond bends if provided for a bar in compression, shall only be considered for development length.
4.Spacing of Reinforcement
NOTE:
The spacing given in the table are not applicable to members subjected to particularly aggressive environments unless in the calculation of 'the moment of resistance,
fs, has been limited to300N/mm2 in limit state design and σs limited to 16'N/mm2 in working stress design
https://www.jswneosteel.in/build/tmt-bars-bis-specifications.aspx 3/4
5/20/2018 Technical Details Relating To TMT Bars As Per BIS Specifications
Extreme 70
NOTE:
For main reinforcement up to 12 nn diameter bar for mild exposure the nominal cover may be reduced by 5 mm.
Unless specified otherwise. actual concrete cover should not deviate from the required nominal cover by + I0 mm
For exposure condition 'severe' and 'very severe'. reduction of 5 mm may be made where concrete grade is M35and above.
Nominal Cover
Fire Resistance
Beams Slabs Ribs Column
Simply Supported Continuous Simply Supported Continuous Simply Supported Continuous
h mm mm mm mm mm mm mm
0.5 20 20 20 20 20 20 40
1 20 20 20 20 20 20 40
1.5 20 20 25 20 35 20 40
2 40 30 35 25 45 35 40
3 60 40 45 35 55 45 40
4 70 50 55 45 65 55 40
Source: IS 1786 (2008), IS 456 (2000)