0% found this document useful (0 votes)
26 views1 page

Coupling Parameters Control Guide

This document provides specifications for coupling parameters for casing and tubing. It lists the required dimensions for internal diameter, width, taper, lead, height and stand-off for different size couplings. Frequency of inspection is specified as inspecting the first two pieces per shift, then every 20 pieces for full parameter inspection. Stand-off must be inspected every 5 pieces. If a rejection occurs, all parameters must be recorded along with the reason for rejection and inspection frequency increased until stable.

Uploaded by

jmezap
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
26 views1 page

Coupling Parameters Control Guide

This document provides specifications for coupling parameters for casing and tubing. It lists the required dimensions for internal diameter, width, taper, lead, height and stand-off for different size couplings. Frequency of inspection is specified as inspecting the first two pieces per shift, then every 20 pieces for full parameter inspection. Stand-off must be inspected every 5 pieces. If a rejection occurs, all parameters must be recorded along with the reason for rejection and inspection frequency increased until stable.

Uploaded by

jmezap
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Coupling Parameters Control of Casing

Coupling

Threads

Diameter of recess
(mm)

Width of
Bearing face
(mm)

Taper
(mm/M)

Lead
mm/Tooth

Height
(mm)

Stand-off
(mm)

Size

O.D.
(mm)

Length
(mm)

4-1/2" BC

1271%

225.42

117.86

3.18

60-67

25.40.0508

1.5750.025

0-2.54

5-1/2" BC

153.671%

234.95

143.26

3.97

60-67

25.40.0508

1.5750.025

2.54-5.08

7" BC

200.031%

254.0

181.36

5.56

60-67

25.40.0508

1.5750.025

2.54-5.08

Note1. Inspect first 2 pieces per shift and record, then every 20 pieces per full parameters and record;
2. Height shall be inspected 100% and stand-off shall be inspected 1pcs per 5pcs;
3. When rejected one was found, recording all parameters and noting the reason rejected, and increasing the frequency of such inspection item until qualified and
stable;
A+(S1 S).
4. Value of Stand off =A+(S1-S).

Coupling Parameters Control of Tubing


Coupling
Si
Size

Diameter of
recess
(mm)

Boring
D th
Depth
(mm)

Width of
B
Bearing
i face
f
(mm)

Threads
Taper
(mm/M)

Lead
mm/Tooth

Height
(mm)

Stand-off
(mm)

3.97

59.9-67.7

25.40.076

1.71-1.861

6.5253.175

9.53+0.79

5.56

59.9-67.7

25.40.076

1.71-1.861

6.5253.175

96.85+0.79

9.53+0.79

6.35

59.9-67.7

25.40.076

1.71-1.861

6.5253.175

122.25+0.79

9.53+0.79

6.35

59.9-67.7

25.40.076

1.71-1.861

6.5253.175

O.D.
(mm)

Length
(mm)

2-3/8" EU

77.81%

123.82

67.46+0.79

9.53+0.79

2-7/8" EU

93.21%

133.35

80.16+0.79

3-1/2" EU

114.31%

146.05

4-1/2" EU

141.31%

158.75

Note1. Inspect first 2 pieces per shift and record, then every 20 pieces per full parameters and record;
2. Stand-off shall be inspected 1pcs per 5pcs;
3. When rejected one was found, recording all parameters and noting the reason rejected, and increasing the frequency of such inspection item until qualified and
stable;
4. Value of Stand off =A+(S1-S).