UPS con Protección y Auto Prueba

The document describes the characteristics of an uninterruptible power supply (UPS) unit, including that it allows for autonomous operation when the main power fails, protects connected devices from power issues, and provides stable current even when the voltage fluctuates through its interactive linear UPS system with automatic voltage regulation. It also details protections for batteries, automatic shutdown during overloads, audible and software alarms, interfaces, and battery monitoring functions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
75 views1 page

UPS con Protección y Auto Prueba

The document describes the characteristics of an uninterruptible power supply (UPS) unit, including that it allows for autonomous operation when the main power fails, protects connected devices from power issues, and provides stable current even when the voltage fluctuates through its interactive linear UPS system with automatic voltage regulation. It also details protections for batteries, automatic shutdown during overloads, audible and software alarms, interfaces, and battery monitoring functions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

CA

RACT
ERÍ
STI
CAS
1.
A UTOP RUE BA:Autop r
u ebac a davezen cendi
da .
Cua ndoUPSe sencendi
da,haceq u
ee l
autopruebaprov
e eu n
ao pe
raci
ón
dec onfi
anzaei mpidea l
gú nd añ ocausado .
PROT ECCIÓNDEBA TE RÍA: Autop r
uebayp rot
ecciónded escar
ga.
2.ARRA NQUEDCCA PA CIDA D:E lUPSp ued eseract
ivadosincor
ri
e nt
egen e
ral
.
3.UPSSA L
IDA SCONCORRI ENTESUMI NISTRADA S:Li
nea r
-I
nter
acti
vaUPS+A VRPermit
e75%a125%c ampod ee nt
rada
dev ol
tajelame jo
rp r
o tecciónp a raequiposinf
ormá t
icos.Confunci
ónA V
R( c
onvert
idorel
evador/reduct
or)
,
UP Sproveec or
rie
ntee s t
a bleal ascargasc uandoflu
ctuélae n
tra
d adevolt
aje.
4.PROT ECCIÓNE LECTRI CA :Co rteautomá t
icoconc o
rtescir
cuit
osoI n
ter
ruptord
eCi r
cui
todeE n
trada.SiUPSs esobr
ecar
ga,
esteinter
ruptordecircu i
tos ea ctiva
ráp a
rad esconect
a rl
au ni
dadd ecor
rie
ntegeneral
.Luegoelbot
ó nnegr
os alt
ará
,yning
unas
delass ali
dasd eprotec ci
ó nd es ubi
dasp roveer
ác or
ri
ente.Desenchufa
rp o
rlomeno sunapiez
ad el
e qui
po,yrepongaeli
nt
err
upt
or
dec i
rcuit
ov ol
viendoaa preta relbotónens ulugarori
ginal.
5.PROT ECCIÓNDEMODE M/ RED: RJ45JA CK;Protecc
ións i
mu l

n eaparare
d,tel
éfono,f
ax&mo dem.
6.ALARMAA UDIBLE:Ba ck-upp a raBater
ía :p
it
idoslentos(10segundos)Bat
erí
aBa j
aySo br
ecargaoSo br
ecargaCA:
Pi
tidosrá p
idos(1Se gu nd o)
7.
INT ERFASEYSOF TWA RE :USBI nter
fase.Soft
wa r
eP ar
aMS- Windows98/ NT/ME/ 2000RS-232I n
terf
ase.
SoftwareP ar
aMS- Wi nd ows98/ NT/ME/ 2000, Novel
l,Linux
8.CPUCONT ROLMI CROP ROCE SO,USA RCONE STABILI
DA D.
9.FUNCIÓNV ERDE:Si lab ateríae st
ád es
c argan
d obajoningúnti
pod ecarg
a,secortar
áa u
tomátic
ame nt
epa rama n
tener
l
av idaútil
d elabatería.
10.FALLAd eb at