You are on page 1of 6
FREE Shipping on orders over $50 ater you signi Search by keyword of model Home / Resource Hub PVC Pipe Sizes: A Guide To Sizes and Dimensions Discover the essential information about PVC pipe sizes and dimensions in this guide Learn more about pipes and find the right fit for your project. 20/03/2021 - Zoro Staff ove Depending on the project at hand, you may need to buy new PVC pipes. PVC pipes vary in size and are broken down into three main categories: schedule 40, schedule 80, and schedule 120. To avoid misuse, plumbing ‘malfunctions, or pushing back a piping project i's helpful to do your research and find the right product fit. It could save you and your team time and money from reordering materials or fixing future pipe issues. PVC pipes are measured on a nominal system, This means all measurements are based on the types of structures versus specific measurements, For instance, 0.84 inches measured from one pipe's end to another is classified as a onednch pipe. There are also different uses for each type of pipe schedule. Keep reading to Understand each PVC pipes size and uses for your next job. How to Measure Your Current PVC Pipe Size Measure from one outside edge of _™ \ the pipe to the other outside edge. Your Measurement ‘Average Outer Diameter (00) Diameter Pvc Pi ose" w 10s" w & ‘Your Measurement ‘Average Outer Diameter (0D) Diameter PVC Pipe Size Translation ais r st te 1a 2378" x as" r . aw 4s * 5.563 s 6.628 ° 8.628 v0.75 w “Works for Schedule 40 and Schedule 80 PVC pipes. Pipe measurements are calculated on a nominal scale. This means their measurements reference structures at hand over true scale measurements, To help translate the correct size of pipes you need, we included a helpful guide above. Here's a step-by-step guide to using the chart: 1. Place your pipe on a hard surface and face one end towards you 2 Grab a tape measure or ruler to measure your pipe’s right outer edge to its left outer edge. Keep your ruler as level as possible while measuring 3. Now. pair “Your Measurement” with the “Average OD" referencing the chart above. 4. Pick out your pipes based on the Average OD your measurement paited with Keep in mind, these measurements refer to the outer edge of the pipe, not the inner. Depending on the schedule of pipe you need, your inner measurements may fluctuate Schedule 40 PVC Pipe Dimensions Nominal Pipe Size Outside Diameter Min. Wall Inside Diameter Linear Weight Density (anches) (00) Thickness () eset) 18 0.405 0.068 0249 0.051 14 0.540 0.086 0.344 0.086 38 0.675 0.091 0473 ons 12 0.840 0.109 0.802 0.170 34 1.050 ons 0.808 0.226 1318 0.133, 1.023 0.333, 1s 1.860 0.140 1.360, 0.450, ve 1.900 0.145: 1590 0.537 2 2375 0.154 2.047 0.720, 22 2875 0.203, 2.445; 1136 a 3.500 0216 3.042 1.488 312 4.000 0.226 3521 area 4 4.500 o2a7 3.998 ane 5 5.562 0.258 5.016 2074 Nominal Pipe Size Outside Diameter _ Min. Wall Inside Diameter Linear Weight Density (Anches) (oo) Thickness () were 6 6.625 0.280 6.031 3.733, 8 8.625 0322 7942 5619 10 10.750 0.365 9.976 7.965 2 12.750 0.406 11.889 10534 1“ 14.000 0.437 13.073 12.462 16 16.000 0.500 14940 16.286 18 18.000 0.562 16.809 20.587 20 20.000 0.593 yeas 20.183 2m 24.000 ose? 22.544 33,652 Schedule 40 pipes are typically white or silver but can be found in other colors. These pipes are thinner than schedule 80s and 120s. This allows fluids to pass through faster than other pipe schedules. This style upholds great ressure, even for cold water systems. In hot temperatures all three schedules are able to withstand up to 140 degrees. ‘Schedule 40 pipes are commonly used for drainage around buildings and for gas and water ines. The pressure ating for this pipe schedule is 120 to 810 pounds per second inch (PS). As a result, schedule 40 pines are commonly used for potable water systems, golf course construction or pools and spas. Schedule 80 PVC Pipe Dimensions Nominal Pipe Size Outside Diameter Min. Wal Inside Diameter Linear Weight Density (inches) (00) Thickness (o) erry) ve 0.405 0.095 0.195 0.068 va 0540 ons 0.288 0110 318 0.75 0.126 0.407 0.153 we 0.240 oar 0.546 0.225 3a 1.050 0.54 0.742 0.308 1 12315 0.179 0.957 0.450 14 1.560 nat vate 0621 12 1.900 0.200 1.500 0.754 2 2378 oz 1.939 1.043 212 2875 0276 2.280 1.598 a 3.500 0.300 2.064 2.132 4 4500 0337 3.786 316 6 6.625 0.432 5.709 5951 8 8.625 0.500 7.565 9.040 10 10.750 0.593 9.493 13413 2 12.750 0.687 v1.294 18.440 4 14.000 0.750 v2.10 zu9 6 16.000 0843 14213, 29.428 18 18.000 0937 re014 36.487 20 20.000 1.031 vane 44648 Nominal Pipe Size Outside Diameter Min. Wall Inside Diameter Linear Weight Density (Anches) (oo) Thickness () west 2% 24,000 1218 21.418 36341 ‘Schedule 80 pipes are thicker than schedule 40 pipes, but still not the thickest. These pipes are usualy dark gray in color but may vary. Schedule 80 PVC pipes are built thicker and stronger than schedule 40s, and can handle higher pressures with a rating of 210 to 1230 PSI, They'e often used for chemical processing, industrial platin, deionized water lines, and wastewater treatment management, Keep in mind, the thicker the pipe does not equal pipe security. Depending on the solutions you's be transporting and the flow rate you'd like, mishaps can happen if you don't choose the correct size and fit. For instance, ifyou use a heavy pipe for general solution purposes, you flow could be slower than needed. Schedule 120 PVC Pipe Dimensions Nominal Pipe Size Outside Diameter Min. Wall Inside Diameter Linear Weight Density (inches) (0D) Thickness 0) (weft) we 0.840 0.70 0.480 0.296 314 1.050 0.170 0.690 oan 1 1.320 0.200 0.891 0.484 ws 1.860 0.215 1.204 0.649 ie 1.900 0.225 1423, 0.787 2 2.380 0.250 184 wm 2ve 2.880, 0.300 2.239 1.615 3 3.500 0.350 2.758 2.306 4 4500 0.430 3574 19.000 6 6.025 osa2 5.434 36.390 a 2.625 ons 7389 60.440 10 10.750 oeaa : 98.290 2 12.750 1.000 : 128.490 “ 14.000 1.094 : 150.790 16 16.000 1219 : 192.420 18 12.000 1378 - 244,140 20 20.000 1.500 - 296,370 2 22,000 1.625 - 353.610 2 24,000 1.e12 - 429,390 Schedule 120 pipes are one ofthe thickest pipes on the market. With their density, they'e routinely used for non-corrosive of general corrosive projects with less reactive ingredients, Automotive and construction establishments frequently use these materials for maximum durability. Schedule 120's pipe thickness helps slow dovn mild to high-pressure systems with a rating of 380 to 1,010 PSI Depending on the construction site you're working on, contact your state for building code regulations. To avoid miscommunication, ensure you find out pipe schedules needed to properly meet local requirements, nce you have your pipe sizes figured out, you'll be able to move onto the next step: ordering pipe values. To help control your pipe flow, figure out which size valves you may need. When you're ready to install your pipes and valves, be sure to reference our guide. As your team needs more materials or installation information, be sure to reference Zoro's site for expert tips, ticks, and product needs. Sources: Hunker Product Compliance and Suitability ‘The product statements contained in this guide are intended for general informational purposes only. Such product statements do not constitute a product recommendation or representation as to the appropriateness, accuracy, completeness, correctness of currentness of the information provided. Information provided in this {guide does not replace the use by you of any manufacturer instructions, technical product manual, or ther professional resource or adviser available to you, Always read, understand and follow all manufacturer instructions. Related Articles How to install or Remove PVC Pipe Fittings There are two types of PYG pipe fitinge: Schedule 40 mostly utilized in eesidentil settings, whereas Schedule 0 is designed fr indus projects. How to Measure Pipe and Fitting Sizes ‘Conese guide that covers the key aspects of pipe anéfiting measurements. Iti an essential oo for anyone working with pipes ae fitings. Different Types of Pipe Threads Guide [Glossary of Various Pipe Treads, Their Acronyms, and the Uses and Standards That Define Them ‘The Differences Between PVC and CPVC oth PVC and CPVC pies are sturdy and less expensive than metal ping, but do you know the diferences between the two? From operating temperature o their intended application, get to know the key distinctions with ou helpful intographie. Sign Up & Save ‘Save 10% on your next order and get special offers when you signup for Zor emails! Email Address Email Address — Contact Us customer Service From Res! People Phone: (855) 289-9675 Ema astzoro@zoro.com (©2014-2023 Zaa Tale ne righeresred, ~ TemeACondione + PvacyPoksy + O2Net Sey Persoal oration

You might also like