0% found this document useful (0 votes)
36 views6 pages

Flow Rate and Temperature Measurement Data

1. Instrumentation data was collected over time including totalizer, flow rate, temperature, and error readings. 2. Key parameters measured include the standard and measured totalizer, flow rate, inlet and outlet temperatures, and error percentages. 3. The data appears to be from testing a flow instrument as it was found, and then testing it again after adjustments or calibrations were made as indicated by the "As Left" section of data.

Uploaded by

bima rama dunas
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
36 views6 pages

Flow Rate and Temperature Measurement Data

1. Instrumentation data was collected over time including totalizer, flow rate, temperature, and error readings. 2. Key parameters measured include the standard and measured totalizer, flow rate, inlet and outlet temperatures, and error percentages. 3. The data appears to be from testing a flow instrument as it was found, and then testing it again after adjustments or calibrations were made as indicated by the "As Left" section of data.

Uploaded by

bima rama dunas
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd

Instrumentation

As Found
Totalizer Flow Rate
Time (min) Err
Std meas Std Meas
1 93.3789 92.3685 5602.734 5542.11 -60.624
1 267.1389 266.9001 10425.6 10471.896 46.296
1 546.6575 545.9690 16771.116 16744.134 -26.982
1 -32799.45 -32758.14 41.31

DUT K In Temp -°C


DUT Z 10 Out Temp -°C
Std.Z
Std

11
K 1.940300 20
Z +11 29.5
Pre-Print As Left
Err (% of Std (kg/h) Meas (kh/h) Err of rdg Totalizer
Time (min)
Rdg) Std meas
-1.0820432 1 93.2131 93.3391
0.4440608 1 267.2413 267.3413
-0.1608837 1 535.6237 535.7566
-0.1259472 1
Std 16771.1
Meas 16744.1 DUT K
Old K 1.9403 DUT Z
New K 1.9434 Std.Z -
Std
Pre-Print
Flow Rate Err (% of Std (kg/h) Meas (kh/h)
Err
Std Meas Rdg)
5592.786 5600.346 7.56 0.1351741
10441.692 10440.132 -1.56 -0.0149401
16102.944 16104.918 1.974 0.0122586
-32137.422 -32145.396 -7.974 0.0248122

In Temp -°C
Out Temp -°C

Z - 55
K 0.6670
Err of rdg
A
As Found
Totalizer Flow Rate Err (% of
Time (min) Err
Std meas Std Meas Rdg)
1 0 0 0 #DIV/0!
1 0 0 0 #DIV/0!
1 0 0 0 #DIV/0!

DUT K - In Temp -°C


DUT Z - Out Temp -°C
Std.Z -
Std F50/R60ACB02000 ©
Pre-Print
Std (kg/h) Meas (kh/h)Err of rdg

You might also like