ShiKag's Engineering Labs Pvt. Ltd.
(Formerly known as Hyderabad Engineering Labs)
( NABL Accredited Lab, An ISO : 9001 & ISO : 45001 Certified Lab)
EE
Reg. Off. & Laboratory : #5-9-16/10, Prashanthi Nagar, Indl Estate, Kuketpally, Hyderabad - 600 072. India
Phone : 401-72 07 077870 Telatax :040-23075850 E-mail : shikags.enga@amail com | sbinydlabs @amaicom
TENSILE TEST REPORT ara ip nee
Work OrderNo : SEL/N/23/3320
Test ReportNo:_M-N23-786
‘Customer Name & Address:
‘AL-HAMID CONSTRUCTION AND ENGINEERS 2 Universal Testing
PLOT NOK 30, SAMTAL VIHAR GHAZIABAD Machine
:FIE/UTN-40
+ 10/90-1346
Calibrated Date 127.07:2023
Next Due Date 26.07.2024
‘Sample Recieved As: TEST PIECE
Ref. No: REQUEST FORM Ref. Date : 06.09.2073
Identification: PIPE - 12 NB,SCH-40 (10 MM) ‘Sample No ry
Test Procedure + ASTM A370:2020
Material Specification: ASTM AS3/AS3M GRB
‘Stamped Ast
Results Specified values |
Specimen Type at Uutimate Load 59.350
‘Speamen width 2 12.56 Utimate Tensile Strenath 471.593 415 (HIN)
Specimen Thickness 5 10.02 Elongation 30.640 28 (MIN)
Cis Wea 125851 Weld Load 41.520
Orignal Gauge Lenath 2 50 Yielo Stress 329.917 240 (IN)
Final Gauge Length + 65.32
Remarks: TEST RESULTS CONFORMS TO THE ABOVE SPECIFICATION
{these Results petaine othe samples reed a oa
[Lins hecanme os eroded fall or part tout our writen pormicon
Witnessed ByShikag's Engineering Labs Pvt. Ltd.
(Formerly known as Hyderabad Engineering Labs)
(NABL Accredited Lab, An ISO : 9001 & ISO : 45001 Certified Lab)
Reg. Off. & Laboratory : #5-9-16/10, Prashanthi Nagar, indi, Estate, Kukatpally, Hyderabad - 500 072. India
Phone : +91-72 07 077870 Teletax : 040-23075850 E- shikags.engg@ gmail.com / sbkhydiabs @ gmail com
CHEMICAL ANALYSIS TEST REPORT.
01, Customer M/s. AL-HAMID CONSTRUCTION AND ENGINEERS
PLOT NO# 30, SAMTAL VIHAR GHAZIABAD.
02, Work Order No & Date : SEL/N/23/3320 Di: 06.09.2023
03. GP.No. & Date = Letter Dt: 06.09.2023
Sample received Date Dt: 06.00.2023
Tested Date De: 06.09.2028
04. T.C.No. & Date = C1950 De: 06.09.2023
05. Sample Description 12NB SCH 40 PPE
06. Specification/ Grade ASTM AS3/A53M GRB
07. Equipment Used Optical Emission Spectrometer
08. Test Reference __ ASTM A751
Sample Identification __| C¥%
Mi fe
Max | 030 | 120 | 0.045 0.050
Specification requirements
12NB SCH 40 PIPE 0.21 | 080 | 0.030 | 0.038
So ran | L
Remarks: The elements tested are within the limits of the above specification
Lab Lest No.C25-1950,
‘Note: 1)This result pertains to the samples received at our lab
2) This TC, cannot be reproduced except in full without our written permission
Tested By
FORMAT No‘SEt/F/008/00 Page 1 of 1