0% found this document useful (0 votes)
129 views1 page

Building Plan Details

This architectural drawing shows the north elevation of a building. It displays the exterior walls and notes their various thicknesses and materials. Dimension lines and callouts provide precise measurements of the walls, windows, and other structural elements. Notes indicate that all dimensions should be verified on site and written dimensions take precedence over scaled measurements.

Uploaded by

Asiimwe Kasirika
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
129 views1 page

Building Plan Details

This architectural drawing shows the north elevation of a building. It displays the exterior walls and notes their various thicknesses and materials. Dimension lines and callouts provide precise measurements of the walls, windows, and other structural elements. Notes indicate that all dimensions should be verified on site and written dimensions take precedence over scaled measurements.

Uploaded by

Asiimwe Kasirika
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

GENERAL

NORTH ELEVATION NOTES


12.993 1.All dimensions to be checked
0.200 2.000
0.200
1.500
0.200
1.000 0.200
12.993
3.293 0.200 4.000 0.200
on site, written dimensions to
4.322 0.700 1.521 1.200 2.670 1.200 1.380 be followed
A B C D in preference to scaled

A
dimensions
0.200
0.267

ROOF NOTES MPO


NDW 2. All dimensions are in meters
1 1 E-C
UST
OM
S RD
unless stated otherwise.

0.200
W3 W2 W2
Corrugated roofing sheets
0.2000.7000.2000.7000.2000.700
1.500 0.6131.0000.5111.0000.5741.000

W3

D1
100x50mm Purlins at 1175 c/c 3. All Reinforced concrete
BEDROOM 100x50mm Rafters work is to be done in

3.400
BEDROOM
W3

D1 accordance with

4.242
100x50mm Ties & Struts
150x50mm Tie beam structural Engineers details.

5.500
4. All Sanitary work to be done

0.200
W3

D1

D1 D1 D1 100x75mm wall plate


225x25mm Facia boards in accordance with the M.O.H

0.700
D2 D2 rules and

D1
0.900

1.500
WC 0.200 WC
D4

0.200 0.200

W3
0.200 1.300 1.793 2.500 1.300 0.200 Regulations
5 4 3 2 1

0.558
W3 W3
2 2 CEILING NOTES 5.All waste pipes and soil

0.156
pipes are to be in ducts and
0.200

0.200 2.600 0.200


EAST ELEVATION

100X50mm Ceiling Joists at site


W2

600mm c/c on the bends to have


66 expanded metal lathe nailed
13.700
13.700

13.700
2.278

2.600
3.8 all cleaning eyes accessible
using roundwire nails on joists
LIVINGROOM
4.701
3.700

Apply one coat universal undercoat, from outside.


D2

WEST ELEVATION
2 coats PVA based emulsion paint
(white) 6.All drainage passing under
3 3

0.800
SITE LOCATON

0.166
the building and the drive
STORE

W3 0.200 3.500 0.200 1.500 0.200 2.600 0.200 1.500 0.200 3.400 0.200 NOT ON SCALE

0.200
PORCH 0.200 WC

1.500
Area to be of
D1

0.200 3.700 0.200 1.300 0.200 2.993 0.200 1.807 1.993 0.200
FOOTING NOTES
D2 D1 PVC pipe & encased in
0.200

D1 200X600mm concrete
4 4
D1

concrete.
W3

2.400
strip foundations

0.200
W2 W2
(mix:1:3:6) to receive
7.All inspection chambers in
0.700

D1

5.600

5.600
200mm plinth walls.
Foundatuion depth to drive way Area to have heavy

0.100
4.100

0.200
be determined at site

0.050
BEDROOM LIVINGROOM

3.500
duty covers.
BEDROOM but not less than
3.334

0.200
750mm 8.All the work to carried out in
0.600 accordance with council

0.200

0.200
0.600 0.600 0.600 0.600 0.600
Regulations
5 5 3.700 1.700 2.800 5.300
9. Provide damp proof course
0.200

0.200
W1
5 4 3 2 1 ROOF PLAN under all walls
A B C D
A

FOUNDATION NOTES 10. All internal plaster to be


1.023 2.000 9.969
0.200 3.700 0.200 4.493 0.200 4.000 0.200 300X300 mm Ceramic tiles on two coats steel float finished
12.993 25mm cement screed on INTERNAL DIMENSIONS CAPACITY NO. OF
12.993 200mm Reinforced concrete slab (1:3:6) mix 20 grade USERS
11. All painting to be three
L1 L2 H1 H2 B
on Cu. M
3.2
coats
1540mm 760mm 1600mm 1750mm 760mm 10
SOUTH ELEVATION 50mm binding layer(dry moist sand) on
200mm well levelled hardcore on 1900mm 900mm 1800mm 2000mm 900mm 4.5 20 12. All doors to be rebated &
well compacted murrum layer 2000mm 1000mm 1800mm 2100mm 1100mm 5.9 30 moulded & full width of wall
2400mm 1100mm 1800mm 2100mm 1150mm 7.24
A-A SECTION
40 with moulded
2500mm 1200mm 1800mm 2100mm 1300mm 8.6 50
A B C 1300mm 1800mm 2100mm 1400mm
& full width of wall with
D 2700mm 10 60
5 4 3 2 1 2900mm 1400mm 1800mm 2100mm 1450mm 11.3 70 moulded architrave to detail,
3000mm 1500mm 1800mm 2100mm 1560mm 12.7 80 provide rubber
1600mm 1800mm 2100mm 1600mm 14
3200mm 90 stop to all doors.
1700mm 1800mm 2100mm 1700mm 15.4 100
3300mm 13. These Architectural
4000mm 2200mm 1800mm 2100mm 2190mm 24 150
2700mm 1800mm 2100mm 2650mm 34.3 200
drawings shall be read in
4500mm
conjunction with
SEPTIC TANK DETAILS: Scale: 1:50
structural, electrical,
WATER PROOF RENDERING IN
200 mechanical drawings, BOQ &
TWO 100mm LAYERS EACH technical
LAYER BRASHED WITH
VANDEX
20
specifications
75 175
PICTORIAL VIEW 14. The Architect shall not

20

50
175 50
Y12 10 - 200 C/C
75 accept any liability, for which
CONC. WEIR
Y12 06 - 200 C/ he has not been
BLOCK DETAIL INTERNAL WATER PROOF TO expressively instructed to
A B C D 750x600mm
Scale 1:25 WALLS AND SLABS Scale 1:
surpvise in writing, or for any
5 4 3 2 1 OPENNING AND
CAST IRON MEDIUM DUTY CAST IRON MEDIUM DUTY COVER AND ommission or
SOUTH ELEVATION COVER AND FRAME FOR FRAME FOR CLEAR 600x450mm OPENNING

WEST ELEVATION
CAST IRON
MEDIUM DUTY COVER
CLEAR 600x450mm OPENING
AND BEDDED INTO
AND BEDDED INTO CEMENT MORTAR
Y12 02-150 C/C both ways (BOT) deviation from his
FRAME FOR CEMENT
MORTAR
CEMENT MORTAR Y12 02 - 150 C/C both ways (BOT)
GROUND LEVEL
drawing/technical
INLET PIPE specification.

450
150mm dia. 50
1100
1 2 3 4 5

1800
C.I dip pipeTOP WATER LEVEL

375
D C B A

375
Y12 10 -
45o FILLET 100mm DIA. OUTLET PIPE 200 C/C
TO DRAINAGE SOAK PIT/

1800
PERCOLATION TRENCHES

2100
3Y12 05-175C/C
Revision History
12Y12 04-175C/C Y12 06 - 200 C/C 50mm blinding
2000 1000 RevID ChID Change Name Date
SECTION B - B Scale 1:50
Y12 10 - 200 C/C

50mm BLINDING
10Y12 08 - 200 C/C
Y12 06 - 200 C/C 900
GROUND LEVEL
SECTION A - A Scale 1:50

3400

300
200
B 200
Invert level

2000 1000 Selected stone

750
200
A A
H
00T
LA B2 600

3,000

1100
S ES
D C B A RC
BA CROSS SECTION THRU DRAIN PIPE
1 2 3 4 5 TRENCH

200
NORTH ELEVATION
B
EAST ELEVATION BASE SLAB PLAN Scale 1:50 MUROK LINK AGENCIES LIMITED
Selected filling well compacted and
consolidated. DRAWN BY:
TECH: ASIIMWE MOSES
Window Schedule
CONTACT:0702209060/0783453648
Door Schedule
Element ID W1 W2 W3 Email: asiimwemoses075@gmail.com
DOO - 024 D2 D1 D2 D3 D5 D4
1 1 12 1 1 1 1 Quantity 1 5 9 Signature: ...................................
INLET PIPE 0TH NAME OF SURPERVISOR:
2,278×2,000 1,300×2,400 900×2,400 1,300×2,400 900×2,400 900×2,400 900×2,400 W x H Size 2,000×1,800 1,200×1,500 700×700
B 15

5000 min
L A ENG. BWAMBALE JORAM
1,900 2,400 2,400 2,400 2,400 2,400 2,400 Orientation
O FS
RO Inlet pipe SIGNATURE: .............................
RC
PROJECT NAME:
2D Symbol Selected PROPOSED COMMERCIAL BUILDING
CONCRETE
BENCHING 10mm DIA. OUTLET PIPE stone profile. OF
RETURNED TO MR. MBALE HARBERT
AT SOFFIT HEIGHT OF DRAINAGE SOAK PIT/
PIPE AT PERCOLATION PROJECT LOCATION:
1:12 SLOPE TRENCHES SECTION THRU SOAK PIT OR NYABUGANDO
ROOF SLAB PLAN scale 1:50 PERCOLATION TRENCH I VILLAGE, NYABUGANDO WARD,
2,400

2,400

2,400

2,400

2,400

2,400

3D Back View MPONDWE LHUBIRIHA TOWN


2,000

COUNCIL,
SEPTIC TANK DETAILS: Scale: KASESE DISTRICT.
1,300 900 1,300 900 900 900 1:50 Modified by Date
2,278 ASIIMWE MOSES
N.T.S On A1paper
Checked by Date
BWAMBALE JORAM

Drawing Scale
1:100

GSPublisherVersion 0.5.100.100

You might also like