PROTOCONVERT PTY LTD.

9 Saffron Place,
Point Cook , Vic 3030
Australia

BACnet, Modbus, LonWorks, SNMP, JCI Metasys N2, and many other industry
standard protocols are best in class options for connecting devices. Also, we can
make custom interface solutions for the integration of hardware that use proprietary
protocols.

Our media converters use fibre optics technology to enable long-distance data
transmission. Long distance data transmissions from RS-485, RS-232, LonWorks, or
CAN networks are possible without running the danger of electrical interference-
related data corruption.

Moreover, we provide a variety of IIoT solutions. We have the ideal option if you wish
to monitor or control your field equipment online or store data from them in the
cloud.

We offer entire solutions for data transfer, remote monitoring, and integration.
Achieving data exchange across devices with various communication interfaces is
something we can assist you with. Furthermore, you may use our solutions to
remotely monitor your equipment and log data. Technology specialists from various
areas of data communication make up our team. We provide consulting, software,
and hardware solutions that allow for the transfer of data over a variety of media
and using different technologies.

We are dealing in gateway/ converter, media converts, IIoT solutions.

+61 424 706 701


www.protoconvert.com.au
Gateway/Converter

BACnet Gateways
Modbus Gateways
SNMP Gateways
JCI Metasys N2 Gateways
LonWorks Gateways
KNX Gateway
OPC UA/DA Gateway
Agilent Gateway
CAN Gateway
Veeder root/OPW gateways
Vaisala Weather
Fire alarm panel Solutions
Siemens Fire Alarm Pan
SIEMENS XLS/MXL
SIEMENS FC92X/FC72X
EST fire alarm panel
EST ECP
EST QuickStart
Schneider Electric's fire alarm panel
Simplex Fire Alarm Panel
Simplex 4100
Simplex Minerva
Hochiki Fire alarm Panel
Hochiki EN
Hochiki UL
Hochiki MCE
Fike cheetah Fire Alarm Panel
Farenhyt Fire Alarm Panel

+61 424 706 701


www.protoconvert.com.au
Honeywell
Notifier Series
Notifier 1010-2020
Notifier AFP 200-300-400
NOTIFIER CEI-ABI
Notifier INA
Notifier Italia AM6000
Notifier NCA
Notifier NFS-3030
Notifier NCA2-NFS2-3030
Notifier Onyx-640
Notifier Onyx-NFS-640
Gamewell Series
Gamewell
Gamewell FCI 7100
Gamewell FCI 7200
Gamewell FCI E3
Silent Knight

Media Converter

Fiber optics to LonWorks


Fiber optics to RS485
Fiber optics to RS232
Fiber optics to Can
Fiber optics to DeviceNet
Fiber optics to ProfiBus DP
RS485 to 4 Port RS485 HUB
RS232 to 4 port RS485 HUB
RS485 to RS232 converter
10 Differential/ 20 Single-ended Analog Inputs to Modbus RTU
Converter
16 Channel Isolated Digital Input to Modbus RTU Converter
16 Channel Non-Isolated Digital Output to Modbus Converter
12 Channel Power Relay output from Modbus RTU
M-bus to RS-232 / RS - 485 Master
+61 424 706 701
www.protoconvert.com.au
IIoT Solutions

Modbus/BACnet/SNMP Datalogger
Modbus/BACnet/SNMP to MQTT (Bi-directional)
Modbus/BACnet/SNMP to REST API (JSON & XML) (Bi-directional)
Modbus/BACnet/SNMP to ASCII (Bi-directional)
Modbus/BACnet/SNMP to Email/SMS
Modbus/BACnet/SNMP to SQL (My SQL & MS SQL)

Monitoring and Controlling Solution

PROSOFT
PROBOARD
PROBOARD+

+61 424 706 701


www.protoconvert.com.au
BACnet Converter

BACnet is becoming the most commonly used protocol for building automation
networks. The most popular flavors of BACnet in use today are BACnet MSTP and
BACnet IP. We have solution for both the flavors of BACnet.
Please refer the table below for part numbers of popular combinations of BACnet
Gateways.

BACnet Modbus Metasys


BACnet IP Modbus TCP LonWorks SNMP
MSTP RTU N2

FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0-


BACnet IP
0285 0237 0104 0122 0131 0333
BACnet FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0-
MSTP 0285 0419 0367 0309 0345 0694

Hardware Specifications

Ability to interface from 250 to 5000 points.


Non-LonWorks model has 2xRS485 ports,
1xEthernet port.
Protonode series model has 1xRS485 port,
1xLonworks port and 1xEthernet port.
BTL Mark – FS-QS Series
Lon Mark Certified – FS-QS Series
Supports BACnet COV
Power Supply: 24VAC 0.125A
9-30VDC 0.25A @12 VDC

+61 424 706 701


www.protoconvert.com.au
BACnet Modbus
BACnet IP Modbus TCP SNMP
MSTP RTU

BACnet IP PG-702x-102-103 PG-702x-101-103 PG-702x-103-100 PG-702x-103-104

BACnet
PG-702x-102-103 PG-702x-102-101 PG-702x-102-100 PG-702x-102-104
MSTP

Hardware Specifications

Ability to interface from 1000 to 10000


points.
Attractive Tabular dashboard for
Monitoring / controlling live data
Gateway has 1/2/3/4 x RS485 ports,
1xRS232 port, and 1 Ethernet port.
Log up to 200,000 values
Supports BACnet COV

*Email/SMS/REST API drivers available.


*Driver availability depends on hardware selection. for
more information please contact us.

+61 424 706 701


www.protoconvert.com.au
Modbus Converter

Modbus protocol is widely acceptable and use as a communication interface for


devices. The most popular flavors of Modbus are Modbus RTU(Remote Terminal Unit)
and Modbus TCP/IP.
Please refer the table below for part numbers of popular combinations of Modbus
Gateways.

BACnet Modbus Metasys


BACnet IP Modbus TCP LonWorks SNMP
MSTP RTU N2
FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-1011- FS-QS-2xx0-
Modbus TCP
0237 0419 0030 0117 0154 0248
FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-1011- FS-QS-2xx0-
Modbus RTU
0104 0367 0030 0038 0085 0334

Hardware Specifications

Ability to interface from 250 to 5000 points.


Non-LonWorks model has 2xRS485 ports,
1xEthernet port.
Protonode series model has 1xRS485 port,
1xLonworks port and 1xEthernet port.
BTL Mark – FS-QS Series
Lon Mark Certified – FS-QS Series
Supports BACnet COV
Power Supply: 24VAC 0.125A
9-30VDC 0.25A @12 VDC

+61 424 706 701


www.protoconvert.com.au
BACnet Modbus
BACnet IP Modbus TCP SNMP
MSTP RTU

Modbus TCP PG-702x-101-103 PG-702x-101-102 PG-702x-100-101 PG-702x-101-104

Modbus RTU PG-702x-100-103 PG-702x-100-102 PG-702x-100-101 PG-702x-100-104

Hardware Specifications

Ability to interface from 1000 to 10000


points.
Attractive Tabular dashboard for
Monitoring / controlling live data
Gateway has 1/2/3/4 x RS485 ports,
1xRS232 port, and 1 Ethernet port.
Log up to 200,000 values
Supports BACnet COV

*Email/SMS/REST API drivers available.


*Driver availability depends on hardware selection. for
more information please contact us.

+61 424 706 701


www.protoconvert.com.au
SNMP Converter

Simple Network Management Protocol (SNMP) is a popular standard for management


of IT networks and related devices.
Please refer the table below for part numbers of popular combinations of SNMP
Gateways.

BACnet Modbus Metasys


BACnet IP Modbus TCP LonWorks SNMP
MSTP RTU N2

FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-1011-


SNMP
0333 0694 0248 0334 0150 0337

Hardware Specifications

Ability to interface from 250 to 5000 points.


Non-LonWorks model has 2xRS485 ports,
1xEthernet port.
Protonode series model has 1xRS485 port,
1xLonworks port and 1xEthernet port.
BTL Mark – FS-QS Series
Lon Mark Certified – FS-QS Series
Supports BACnet COV
Power Supply: 24VAC 0.125A
9-30VDC 0.25A @12 VDC

+61 424 706 701


www.protoconvert.com.au
BACnet Modbus
BACnet IP Modbus TCP SNMP
MSTP RTU

SNMP PG-702x-104-103 PG-702x-102-104 PG-702x-101-104 PG-702x-100-104

Hardware Specifications

Ability to interface from 1000 to 10000


points.
Attractive Tabular dashboard for
Monitoring / controlling live data
Gateway has 1/2/3/4 x RS485 ports,
1xRS232 port, and 1 Ethernet port.
Log up to 200,000 values
Supports BACnet COV

*Email/SMS/REST API drivers available.


*Driver availability depends on hardware selection. for
more information please contact us.

+61 424 706 701


www.protoconvert.com.au
JCI Metasys N2 Converter

JCI Metasys N2 is an extremely popular protocol used in Building Automation.


ProtoConvert offers excellent solutions to integrate your JCI Metasys N2 devices on
other communication protocols like Modbus RTU, Modbus TCP/IP, SNMP, BACnet
MSTP, BACnet IP, LonWorks and many others.
Please refer the table below for part numbers of popular combinations of JCI Metasys
N2 Gateways

BACnet Modbus Metasys


BACnet IP Modbus TCP LonWorks SNMP
MSTP RTU N2

JCI Metasys FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-1011- FS-QS-2xx0-


N2 0122 0309 0117 0038 0097 0150

Hardware Specifications

Ability to interface from 250 to 5000 points.


Non-LonWorks model has 2xRS485 ports,
1xEthernet port.
Protonode series model has 1xRS485 port,
1xLonworks port and 1xEthernet port.
BTL Mark – FS-QS Series
Lon Mark Certified – FS-QS Series
Supports BACnet COV
Power Supply: 24VAC 0.125A
9-30VDC 0.25A @12 VDC

+61 424 706 701


www.protoconvert.com.au
M-Bus Converter

M-Bus Quick Server Gateway easily enables data access between M-Bus networks and
devices and other networks that utilize open and proprietary protocols such as
BACnet, Modbus, LonWorks, Metasys N2 by JCI, SNMP and more. With over 100
protocols available in the extensive Field Server Driver Library, no other product can
connect M-Bus to more products!

The EZ Gateway M-Bus to Modbus & BACnet (FS-EZX-MBUS-MD-BAC) is an easy to


use, high performance building and industrial automation protocol gateway for
integrators to interface M-Bus products to Modbus and BACnet management systems
in commercial buildings, campuses and industrial facilities over Modbus RTU, Modbus
TCP/IP, BACnet MS/TP or BACnet/IP protocols.
M-Bus products encompass a wide range of applications such as energy, gas, heating,
water, VFD drives and PLCs.

BACnet Modbus Metasys


BACnet IP Modbus TCP LonWorks SNMP
MSTP RTU N2

FS-QS-1x50- FS-QS-1x50- FS-QS-1x50- FS-QS-1x50- FS-QS-1x50- FS-QS-1x51- FS-QS-1x50-


Mbus
106-108 102-108 101-108 100-108 106-108 105-108 104-108

Hardware Specifications

Ability to interface from 250 to 5000 points.


Non-LonWorks model has 2xRS485 ports,
1xEthernet port.
Protonode series model has 1xRS485 port,
1xMBus port and 1xEthernet port.
BTL Mark – FS-QS Series
Lon Mark Certified – FS-QS Series
Supports BACnet COV
Power Supply: 24VAC 0.125A
9-30VDC 0.25A @12 VDC
+61 424 706 701
www.protoconvert.com.au
KNX Converter

With the Quick Server KNX Gateway, Field Server enables data access from KNX
networks to devices and networks utilizing open and proprietary protocols such as
BACnet, Modbus, LonWorks, Metasys N2 by JCI, SNMP and more. With over 100
protocols available in the extensive Field Server Driver Library, no other product can
connect KNX to more products!

Field Server is in thousands of installations with over 700 translation paths. These
gateways are LonMark certified, BACnet compliant, Metasys N2 compatible and
mission-critical tested.

BACnet Modbus Metasys


BACnet IP Modbus TCP SNMP
MSTP RTU N2

FS-QS-1x40- FS-QS-1x40- FS-QS-1x40- FS-QS-1x40- FS-QS-1x40- FS-QS-1x40-


KNX
103-107 102-107 101-107 100-107 106-107 104-107

Hardware Specifications

Ability to interface up to 1000 points.


Non-LonWorks model has 2xRS485 ports,
1xEthernet port.
Protonode series model has 1xRS485 port,
1xKNX port and 1xEthernet port.
BTL Mark – FS-QS Series
Lon Mark Certified – FS-QS Series
Supports BACnet COV
Power Supply: 24VAC 0.125A
9-30VDC 0.25A @12 VDC

+61 424 706 701


www.protoconvert.com.au
OPC DA Converter

Using OPC DA software applications can retrieve real-time data to enable them to
monitor a given process. In that scenario, OPC DA is used for data acquisition. OPC
DA can also be used to enable a software application to write data to a control
system. This enables OPC DA applications to handle supervisory control. Thus, OPC
DA is well suited for Supervisory Control and Data Acquisition (SCADA) scenarios. OPC
DA is typically used by almost all process control applications that are used as an HMI,
Historian, Advanced Process Control (APC), Maintenance, ERP (Enterprise Resource
Planning), Analysis, Optimization, etc

BACnet Modbus
BACnet IP Modbus TCP SNMP
MSTP RTU

OPC DA PG-702x-103-125 PG-702x-102-125 PG-702x-101-125 PG-702x-100-125 PG-702x-104-125

OPC UA Converter

OPC UA client driver allows connection with a remote OPC UA server and exchange
information. It is possible to poll for tags or subscribe for updates.

• Connects to the OPC UA Server using the IP Address of the host computer and the
name of the OPC Server instance.
• Tags can be configured using the tag names.
• Integer, real and Boolean values are currently supported.

BACnet Modbus
BACnet IP Modbus TCP SNMP
MSTP RTU

OPC UA PG-702x-103-119 PG-702x-102-119 PG-702x-101-119 PG-702x-100-119 PG-702x-104-119

+61 424 706 701


www.protoconvert.com.au
Hardware Specifications

Ability to interface from 1000 to 10000


points.
Attractive Tabular dashboard for
Monitoring / controlling live data
Gateway has 1/2/3/4 x RS485 ports,
1xRS232 port, and 1 Ethernet port.
Log up to 200,000 values
Supports BACnet COV

*Email/SMS/REST API drivers available.


*Driver availability depends on hardware selection. for
more information please contact us.

Agilent Converter

ProtoConvert SCPI driver is designed to connect and read data from an Agilent data
logger. Usability of this driver can be extended to other devices that support SCPI
protocol.
The ProtoConvert SCPI driver is a poll response driver. Only one command can be
processed at a time.
A limited set of the queries and commands defined in the protocol specification have
been implemented. More commands can be implemented based on project
requirements. The ProtoConvert Gateway can emulate Client.

BACnet Modbus
BACnet IP Modbus TCP SNMP
MSTP RTU

Agilent PG-702x-103-142 PG-702x-102-142 PG-702x-101-142 PG-702x-100-142 PG-702x-104-142

+61 424 706 701


www.protoconvert.com.au
Hardware Specifications

Ability to interface from 1000 to 10000


points.
Attractive Tabular dashboard for
Monitoring / controlling live data
Gateway has 1/2/3/4 x RS485 ports,
1xRS232 port, and 1 Ethernet port.
Log up to 200,000 values
Supports BACnet COV

*Email/SMS/REST API drivers available.


*Driver availability depends on hardware selection. for
more information please contact us.

Veeder-Root Converter

The Veeder-Root Serial Driver allows ProtoConvert Gateway to transfer data to and
from devices over either RS- 232 or RS-485 ports using Veeder-Root protocol as
defined in Veeder Root Document 576013-635 Revision J. The Veeder-Root Driver
supports TLS350 as per Veeder-Root Document 576013-635 Revision Y, and TLS450 as
per Veeder-Root Document 577013-950 Revision G. Since the data protocol is
the same for the TLS-350+ as for TL-S350, it is assumed that the driver will support
the TLS350+ but this has not been tested. The Driver also successfully communicates
with the TLS-450 as it has the same data protocol.

BACnet Modbus
BACnet IP Modbus TCP SNMP
MSTP RTU

Veeder-Root PG-702x-103-116 PG-702x-102-116 PG-702x-101-116 PG-702x-100-116 PG-702x-104-116

+61 424 706 701


www.protoconvert.com.au
Hardware Specifications

Ability to interface from 1000 to 10000


points.
Attractive Tabular dashboard for
Monitoring / controlling live data
Gateway has 1/2/3/4 x RS485 ports,
1xRS232 port, and 1 Ethernet port.
Log up to 200,000 values
Supports BACnet COV

*Email/SMS/REST API drivers available.


*Driver availability depends on hardware selection. for
more information please contact us.

Veeder-Root Converter

The Veeder-Root Serial Driver is a poll response driver. Only one query or command
can be processed at a time.
A limited set of the queries and commands defined in the protocol specification have
been implemented. The reason for the limitation
is two-fold. Firstly, not all commands/queries will have any meaning to a Server device
as they are principally defined to
configure the Veeder-Root Device. Secondly, some commands return very complex
data sets which cannot be processed in a
method suitable for loading into the FieldServer’s Data Arrays.
The driver can show communications statistics, which can be monitored using a
Server device.

BACnet Modbus Metasys


BACnet IP Modbus TCP SNMP
MSTP RTU N2

FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0-


Veeder-Root
103-116 101-116 101-116 100-116 106-116 104-116

+61 424 706 701


www.protoconvert.com.au
Hardware Specifications

Ability to interface from 250 to 5000 points.


Non-LonWorks model has 2xRS485 ports,
1xEthernet port.
Protonode series model has 1xRS485 port,
1xLonworks port and 1xEthernet port.
BTL Mark – FS-QS Series
Lon Mark Certified – FS-QS Series
Supports BACnet COV
Power Supply: 24VAC 0.125A
9-30VDC 0.25A @12 VDC

CAN Protocol

Using the CAN Protocol driver it is possible to configure the ProtoConvert gateway as
a CAN passive client and listen for incoming CAN messages. The messages can be
filtered based on their CAN message Ids and the incoming bytes of data can be read
and presented as is.
We can create custom functions to manipulate the data. Please get in touch with our
sales or support team in case such a customization is required.

BACnet Modbus
BACnet IP Modbus TCP SNMP
MSTP RTU

CAN PG-702x-103-194 PG-702x-102-194 PG-702x-101-194 PG-702x-100-194 PG-702x-104-194

+61 424 706 701


www.protoconvert.com.au
Hardware Specifications

Ability to interface from 1000 to 10000


points.
Attractive Tabular dashboard for
Monitoring / controlling live data
Gateway has 1/2/3/4 x RS485 ports,
1xRS232 port, and 1 Ethernet port.
Log up to 200,000 values
Supports BACnet COV

*Email/SMS/REST API drivers available.


*Driver availability depends on hardware selection. for
more information please contact us.

Vaisala Weather

The Vaisala WXT530 Series Weather Transmitter is a versatile and reliable device used
for monitoring weather conditions. Its compact design, low power consumption, and
robust construction make it suitable for a wide range of applications, including
meteorology, aviation, road weather, and marine applications. Integration of the
WXT530 Series into a weather monitoring system is straightforward, thanks to its
compatibility with a range of data communication protocols, including RS232, RS485,
SDI-12, and Modbus. With its advanced sensor technology and ease of integration,
the Vaisala WXT530 Series Weather Transmitter is an ideal solution for accurate and
reliable weather monitoring.

ProtoConvert is a leading provider of gateway solutions that enable the integration of


Vaisala Weather Transmitters with other building automation systems. By publishing
data from these sensors on open protocols like BACnet, Modbus, and SNMP,
ProtoConvert can offer excellent gateways that allow for seamless integration of
weather data into your building automation system. With these solutions, you can
monitor weather conditions in real-time and use the data to control HVAC systems,
lighting, and other building systems to optimize energy usage and enhance occupant
comfort. ProtoConvert's expertise in gateway technology ensures reliable and
efficient integration, making it the ideal choice for Vaisala Weather Transmitter
integration.
+61 424 706 701
www.protoconvert.com.au
BACnet Modbus
BACnet IP Modbus TCP SNMP
MSTP RTU

Vaisala Weather PG-702x-103-274 PG-702x-102-274 PG-702x-101-274 PG-702x-100-274 PG-702x-104-274

Hardware Specifications

Ability to interface from 1000 to 10000


points.
Attractive Tabular dashboard for
Monitoring / controlling live data
Gateway has 1/2/3/4 x RS485 ports,
1xRS232 port, and 1 Ethernet port.
Log up to 200,000 values
Supports BACnet COV

*Email/SMS/REST API drivers available.


*Driver availability depends on hardware selection. for
more information please contact us.

Siemens XLS/MXL

This Field Server driver can be used to poll a Siemens Fire Safety MXL or XLS system
or to emulate a Siemens Fire Safety MXL or XLS system with attached modules. Either
configuration supports remote monitoring as well as selected command and control
functions.

BACnet Modbus Metasys


BACnet IP Modbus TCP SNMP
MSTP RTU N2

Siemens FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0-


XLS/MXL 103-124 102-124 101-124 100-124 106-124 104-124

+61 424 706 701


www.protoconvert.com.au
Hardware Specifications

Ability to interface from 250 to 5000 points.


Non-LonWorks model has 2xRS485 ports,
1xEthernet port.
Protonode series model has 1xRS485 port,
1xLonworks port and 1xEthernet port.
BTL Mark – FS-QS Series
Lon Mark Certified – FS-QS Series
Supports BACnet COV
Power Supply: 24VAC 0.125A
9-30VDC 0.25A @12 VDC

Device Tested

MXL Tested

MXL-Q Tested

XLS Tested

Cerberus Pro Modular Tested

+61 424 706 701


www.protoconvert.com.au
Siemens FC92x/FC72x

The Siemens FC92x driver allows communication with the Siemens FC92X series
panels supplied by Siemens. The Siemens Master Panel, on one side can
communicate with a single or a network of panels and on the other side exposes the
panel alarms, Trouble and Alerts information using its own proprietory protocol.
ProtoConvert gateway helps you to echange information from Panel to BMS/SCADA.

Hardware Specifications

Ability to interface from 1000 to 10000


points.
Attractive Tabular dashboard for
Monitoring / controlling live data
Gateway has 1/2/3/4 x RS485 ports,
1xRS232 port, and 1 Ethernet port.
Log up to 200,000 values
Supports BACnet COV

*Email/SMS/REST API drivers available.


*Driver availability depends on hardware selection. for
more information please contact us.

EST-3

The EST-3 External Communications Protocol (ECP) driver allows the Field Server to
transfer data to and from EST devices over RS-232 or RS-485 (with converter) serial
ports using the EST-3 protocol. In the EST application the Field Server always emulates
a Client. Gateway Type II and Type III formats are supported.

EST QuickStart

The QuickStart Serial driver allows the FieldServer to record data from Edwards
System Technology QS1-2/4-8 and QSC Fire Panels over the RS-232 printer port. The
FieldServer acts as a Passive Client receiving messages and updating its internal data
arrays which records the status of devices connected to the QuickStart fire alarm
control panel. The QuickStart panels currently do not support duplexed
communications; therefore, this driver has only been designed to listen for messages
passively and not to respond or to generate polls +61 424 706 701
www.protoconvert.com.au
BACnet Modbus Metasys
BACnet IP Modbus TCP SNMP
MSTP RTU N2

FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0-


EST3 ECP
103-132 102-132 101-132 100-132 106-132 104-132
FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0-
EST QuickStart
103-138 102-138 101-138 100-138 106-138 104-138

Hardware Specifications

Ability to interface from 250 to 5000 points.


Non-LonWorks model has 2xRS485 ports,
1xEthernet port.
Protonode series model has 1xRS485 port,
1xLonworks port and 1xEthernet port.
BTL Mark – FS-QS Series
Lon Mark Certified – FS-QS Series
Supports BACnet COV
Power Supply: 24VAC 0.125A
9-30VDC 0.25A @12 VDC

Schneider Electric Taktis

The Schneider Electric Taktis driver allows communication with the Taktis module
supplied by Schneider Electric. The Taktis module on one side can communicate with
a single or a network of panels and on the other side exposes the panel alarms and
information using the Taktis protocol. ProtoConvert gateways support the Taktis
protocol and hence can exchange information with the Taktis module.

+61 424 706 701


www.protoconvert.com.au
BACnet Modbus
BACnet IP Modbus TCP SNMP
MSTP RTU

Schneider
PG-702x-103-128 PG-702x-102-128 PG-702x-101-128 PG-702x-100-128 PG-702x-104-128
Electric Taktis

Hardware Specifications

Ability to interface from 1000 to 10000


points.
Attractive Tabular dashboard for
Monitoring / controlling live data
Gateway has 1/2/3/4 x RS485 ports,
1xRS232 port, and 1 Ethernet port.
Log up to 200,000 values
Supports BACnet COV

*Email/SMS/REST API drivers available.


*Driver availability depends on hardware selection. for
more information please contact us.

Simplex 4100

The Simplex Time Recorder Company – 4100 Computer Port Protocol driver allows
the Converter to transfer data to and from devices over RS-232 using Simplex Time
Recorder Company – 4100 Computer Port Protocol.

This driver is designed to connect to a Simplex 4100 panel equipped to support the
“4100 Computer Port Protocol” as defined in Simplex’s document 950-004 Revision E
dated 28 July 2000. The implementation provides a selected subset of protocol
functions and subset of functionality for each of these selected functions. It is
important to note the exclusions and limitations described in this document

+61 424 706 701


www.protoconvert.com.au
BACnet Modbus
BACnet IP Modbus TCP SNMP
MSTP RTU

Simplex 4100 PG-702x-103-130 PG-702x-102-130 PG-702x-101-130 PG-702x-100-130 PG-702x-104-130

Hardware Specifications

Ability to interface from 1000 to 10000


points.
Attractive Tabular dashboard for
Monitoring / controlling live data
Gateway has 1/2/3/4 x RS485 ports,
1xRS232 port, and 1 Ethernet port.
Log up to 200,000 values
Supports BACnet COV

*Email/SMS/REST API drivers available.


*Driver availability depends on hardware selection. for
more information please contact us.

Simplex Minerva

The driver decodes the printer-style output sent form the panel. Only recognised
events are decoded and made available as objects. All alarms from the configured
panel will be routed onwards. The driver is unable to request the current state of the
panel at start-up, therefore the panel should be clear of all events when starting or
resetting the driver.

The driver connects to the panel’s third-party serial port interface. This printer-style
output port provides limited monitoring only, no commands can be sent to the panel.

+61 424 706 701


www.protoconvert.com.au
BACnet Modbus
BACnet IP Modbus TCP SNMP
MSTP RTU

Simplex
PG-702x-103-182 PG-702x-102-182 PG-702x-101-182 PG-702x-100-182 PG-702x-104-182
Minerva

Hardware Specifications

Ability to interface from 1000 to 10000


points.
Attractive Tabular dashboard for
Monitoring / controlling live data
Gateway has 1/2/3/4 x RS485 ports,
1xRS232 port, and 1 Ethernet port.
Log up to 200,000 values
Supports BACnet COV

*Email/SMS/REST API drivers available.


*Driver availability depends on hardware selection. for
more information please contact us.

Hochiki EN

The Hochiki Serial driver allows the ProtoConvert Gateway to record data from
Hochiki EN panels over RS-232. There is no active polling by this driver; the
communications are one-way through the panel's PC port (J5). The ProtoConvert
Gateway acts as a Client; receives messages and records the status of a Panel. The
panel MUST output messages in ASCII format in English.

Hochiki MCE

The Hochiki MCE driver allows communication with the MCE module supplied by
Hochiki. The MCE module on one side can communicate with a single or a network of
panels and on the other side exposes the panel alarms and information using the
MCE protocol.
ProtoConvert gateways support the MCE protocol and hence can exchange
information with the MCE module +61 424 706 701
www.protoconvert.com.au
BACnet Modbus
BACnet IP Modbus TCP SNMP
MSTP RTU

PG-702x- PG-702x- PG-702x- PG-702x- PG702x-


Hochiki EN
103-112 102-112 101-112 100-112 104-112
PG-702x- PG-702x- PG-702x- PG-702x- PG702x-
Hochiki MCE
103-128 102-128 101-128 100-128 104-128

Hardware Specifications

Ability to interface from 1000 to 10000


points.
Attractive Tabular dashboard for
Monitoring / controlling live data
Gateway has 1/2/3/4 x RS485 ports,
1xRS232 port, and 1 Ethernet port.
Log up to 200,000 values
Supports BACnet COV

*Email/SMS/REST API drivers available.


*Driver availability depends on hardware selection. for
more information please contact us.

Hochiki UL

The Hochiki Serial driver allows the Field Server to record data from Hochiki Fire NET
panels over RS 232. There is no active polling by this driver; the communications are
one-way through the panel's PC port (J5). The Field Server acts as a Client; receives
messages and records the status of a Panel. The panel MUST output messages in
ASCII format in English.
This driver is not capable of emulating a Hochiki panel.
The Hochiki Fire NET panel can be a standalone panel or can be part of network. Each
Fire Alarm Panel on Network is considered as a Node. 64 Nodes can exist on one
network.

+61 424 706 701


www.protoconvert.com.au
BACnet Modbus Metasys
BACnet IP Modbus TCP SNMP
MSTP RTU N2

FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0-


Hochiki UL
103-133 102-133 101-133 100-133 106-133 104-133

Hardware Specifications

Ability to interface from 250 to 5000 points.


Non-LonWorks model has 2xRS485 ports,
1xEthernet port.
Protonode series model has 1xRS485 port,
1xLonworks port and 1xEthernet port.
BTL Mark – FS-QS Series
Lon Mark Certified – FS-QS Series
Supports BACnet COV
Power Supply: 24VAC 0.125A
9-30VDC 0.25A @12 VDC

Device Tested

4020 Panel Firmware Revision 9.02 Tested

4100U Panel Firmware Revision 11.03 Tested

4100ES Tested

4010ES Tested

NDU (Network Display Unit) Tested

+61 424 706 701


www.protoconvert.com.au
Fike Cheetah

The Cheetah Protocol driver allows the Field Server to transfer data to and from
devices over either RS-232 or RS-485 using the Cheetah device protocols (Legacy
Cheetah Classic, Cheetah Xi and Cheetah MIM).
The driver supports messages sent from the Cybercat panel. Specifically, the driver
supports message 1.02 which reports panel, zone and device states.
The FieldServer can emulate either a Server or Client but it should be noted that it can
only process unsolicited messages from the Cheetah devices. Thus, it does not
provide an active Client driver. It is best to consider this driver as a consumer only
driver with the data being produced by a Cheetah controller.

BACnet Modbus Metasys


BACnet IP Modbus TCP SNMP
MSTP RTU N2

FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0-


Fike Cheetah
103-139 102-139 101-139 100-139 106-139 104-139

Hardware Specifications

Ability to interface from 250 to 5000 points.


Non-LonWorks model has 2xRS485 ports,
1xEthernet port.
Protonode series model has 1xRS485 port,
1xLonworks port and 1xEthernet port.
BTL Mark – FS-QS Series
Lon Mark Certified – FS-QS Series
Supports BACnet COV
Power Supply: 24VAC 0.125A
9-30VDC 0.25A @12 VDC

+61 424 706 701


www.protoconvert.com.au
Farenhyt

This serial driver connects via RS-232 to the printer port of a Farenhyt Series Black
FACP.
The driver is a passive client driver. It does not poll for data. It waits passively for the
panel to transmit data. When an event is sent to the gateway it evaluates the event
and turns data points on/off. These points are mapped onto BACnet / Modbus etc.
objects so the BMS can read them,
The driver cannot be used to simulate a Farenhyt FACP. Because only the passive
client side of the protocol is implemented.

BACnet Modbus Metasys


BACnet IP Modbus TCP SNMP
MSTP RTU N2

FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0- FS-QS-2xx0-


Farenhyt
103-196 102-196 101-196 100-196 106-196 104-196

Hardware Specifications

Ability to interface from 250 to 5000 points.


Non-LonWorks model has 2xRS485 ports,
1xEthernet port.
Protonode series model has 1xRS485 port,
1xLonworks port and 1xEthernet port.
BTL Mark – FS-QS Series
Lon Mark Certified – FS-QS Series
Supports BACnet COV
Power Supply: 24VAC 0.125A
9-30VDC 0.25A @12 VDC

+61 424 706 701


www.protoconvert.com.au
Notifier 1010-2020
The Notifier driver always functions as a Client, meaning the Notifier Fire Alarm Panel
writes information to the Field Server to be passed on to another device. Three pre-
configured Data Arrays are provided with this driver. The Field Server automatically
assigns the device internal Node ID of station 257.

Notifier Onyx 640


The NFS-640 Serial driver allows the Field Server to record data from Notifier Onyx
Series NFS-640, NFS2-640 and NFS-320 Fire Panels over RS-232. The Field Server
primarily acts as a Passive Client receiving unsolicited messages and updating the
status of a Notifier Fire Alarm Panel.

Notifier NFS-3030
The Field Server acts as a Passive Client receiving messages and recording the status
of a Notifier 3030 Fire Alarm Panel. There is no active polling by this driver; the
communications are one-way through the panel's printer port.

Notifier Italia AM6000


Notifier AM6000 serial driver is a passive client only driver. This means that the driver
is capable of processing and storing data from unsolicited messages sent from a
Notifier panel. It is not capable of polling for data or sending data to a panel. As the
driver does not provide server side functionality it is not capable of emulating a
Notifier panel.

Notifier NCA2-NFS2-3030
The NCA2/NFS2-3030 Serial driver allows the Field Server to record data from Notifier
NCA2 or NFS2-3030 panels over RS-232 as per NFS2-3030/NCA-2 EIA-232 Protocol &
Data Formats 53219 Rev A 1/3/2008. There is no active polling by this driver; the
communications are one-way through the panel's printer or CRT port.

Notifier NCA
The NCA (Network Control Annunciator) Serial driver allows the Field Server to record
data from Notifier NCA over RS-232. The Field Server acts as a Passive Client receiving
messages and recording the status of a Notifier NCA Panel.

+61 424 706 701


www.protoconvert.com.au
Notifier INA
Configuration of the Notifier side of the Field Server is straight forward. The Notifier
driver always functions as a Server, meaning the Notifier Fire Alarm Panel writes
information to the Field Server to be passed on to another device. When the Field
Server is used with the Notifier INA, additional Data Arrays need to be configured for
each Panel connected to the INA. The operator must configure the Data Arrays with
Node ID’s with addresses of station 1, 2, etc.

Notifier CEI-ABI
The driver starts up in a configuration mode during which configuration data is
fetched from the exchanges to determine the zone labels and point to zone
mappings. After finishing configuration mode, the driver proceeds to normally poll
the exchanges for alarm, trouble or event data on points and zones. The driver also
supports the special event code 138 from exchanges which is used to indicate that a
programming change has taken place on the exchange.

Notifier AFP-200-300-400
The Notifier AFP200/300/400 driver allows the Field Server to transfer data to and
from the Notifier AFP200, AFP300 and AFP400 Automatic Fire Alarm Panels over RS-
232 using Notifier AFP200/300/400 protocol. The panel MUST output messages in
English. The Field Server functions as a Client with this driver.

Notifier Onyx-640 (Spanish)


This driver is for use with Notifier 640 Panels equipped with Spanish Firmware as sold
in Mexico. Check with your vendor if your panel has the same firmware. There are
features of this driver that differ from the FS-8700-90 driver and there are limitations.
The NFS-640 (SPANISH) Serial driver allows the Field Server to record data from
Notifier Onyx Series NFS-640 (SPANISH) Fire Panels over RS-232. The Field Server
primarily acts as a Passive Client receiving unsolicited messages and updating the
status of a Notifier Fire Alarm Panel. The Field Server can actively request that the
NFS-640 (SPANISH) send the status of all points, devices and zones on a periodic
basis.

+61 424 706 701


www.protoconvert.com.au
BACnet Modbus
BACnet IP Modbus TCP SNMP
MSTP RTU
Notifier 1010- FS-QS-2xx0-103- FS-QS-2xx0-102- FS-QS-2xx0-101- FS-QS-2xx0-100- FS-QS-2xx0-104-
2020 178 178 178 178 178
Notifier Onyx FS-QS-2xx0-103- FS-QS-2xx0-102- FS-QS-2xx0-101- FS-QS-2xx0-100- FS-QS-2xx0-104-
640 144 144 144 144 144
Notifier NFS- FS-QS-2xx0-103- FS-QS-2xx0-102- FS-QS-2xx0-101- FS-QS-2xx0-100- FS-QS-2xx0-104-
3030 141 141 141 141 141
Notifier Italia FS-QS-2xx0-103- FS-QS-2xx0-102- FS-QS-2xx0-101- FS-QS-2xx0-100- FS-QS-2xx0-104-
AM6000 242 242 242 242 242
Notifier NCA2- FS-QS-2xx0-103- FS-QS-2xx0-102- FS-QS-2xx0-101- FS-QS-2xx0-100- FS-QS-2xx0-104-
NFS2-3030 155 155 155 155 155
FS-QS-2xx0-103- FS-QS-2xx0-102- FS-QS-2xx0-101- FS-QS-2xx0-100- FS-QS-2xx0-104-
Notifier NCA
244 244 244 244 244
FS-QS-2xx0-103- FS-QS-2xx0-102- FS-QS-2xx0-101- FS-QS-2xx0-100- FS-QS-2xx0-104-
Notifier INA
174 174 174 174 174
FS-QS-2xx0-103- FS-QS-2xx0-102- FS-QS-2xx0-101- FS-QS-2xx0-100- FS-QS-2xx0-104-
Notifier CEI-ABI
158 158 158 158 158
Notifier AFP 200- FS-QS-2xx0-103- FS-QS-2xx0-102- FS-QS-2xx0-101- FS-QS-2xx0-100- FS-QS-2xx0-104-
300-400 240 240 240 240 240

Hardware Specifications

Ability to interface from 250 to 5000 points.


Non-LonWorks model has 2xRS485 ports,
1xEthernet port.
Protonode series model has 1xRS485 port,
1xLonworks port and 1xEthernet port.
BTL Mark – FS-QS Series
Lon Mark Certified – FS-QS Series
Supports BACnet COV
Power Supply: 24VAC 0.125A
9-30VDC 0.25A @12 VDC

+61 424 706 701


www.protoconvert.com.au
Gamewell
All Gamewell Fire Alarm panels are equipped with a serial port which produces panel,
circuit or device status messages. This driver is designed to process these messages
and store this status information in numeric form. The numeric value will indicate the
type of event being reported and the storage location in the Field Server’s data arrays
is (configurable &) dependent on the origin of the message (panel / circuit / device).
Additional information such as event date and time and descriptions are ignored.

Gamewell FCI7100
A 7100 with an enabled serial port can transmit data to a Field Server, making the
data available to other devices, including those using different protocols (e.g. BACnet).
This passive Client driver does not poll for data or send data/commands to the 7100.
Messages received from the 7100 are ignored or stored on the Field Server
depending on the status of the panel. The method of message processing and
location on the Field Server is determined in the Field Server configuration file. Once
stored in the Field Server, the data is available to be read or written using other
protocols (e.g. BACnet).

Gamewell FCI7200
The FCI 7200 Series System Control Units (SCU’s) are manufactured by Fire Control
Instruments. A SCU with an enabled serial port can transmit data to a Field Server
which can, in turn, make the data available to other devices including those which
communicate using different protocols (e.g. BACnet). This passive Client driver does
not poll for data, nor does it send data or commands to the SCU. Messages received
from the SCU are ignored or stored on the Field Server depending on the status of
the panel. The method of message processing and location on the Field Server is
determined in the Field Server configuration file.

Gamewell FCI E3
The Gamewell FCI E3 Series System Control Units are manufactured by Fire Control
Instruments. A Gamewell FCI-E3 Panel with an enabled serial port can transmit data
to a Field Server which can, in turn, make the data available to other devices
including those which communicate using different protocols. Messages received
from the E3 are analyzed and are then either discarded or used to update the Field
Server’s internal Data Arrays depending on the configuration of the Field Server. Once
stored in the Field Server the data is available to be read or written using other
protocols.
+61 424 706 701
www.protoconvert.com.au
BACnet Modbus
BACnet IP Modbus TCP SNMP
MSTP RTU

FS-QS-2xx0-103- FS-QS-2xx0-102- FS-QS-2xx0-101- FS-QS-2xx0-100- FS-QS-2xx0-104-


Gamewell
207 207 207 207 207
Gamewell FIC FS-QS-2xx0-103- FS-QS-2xx0-102- FS-QS-2xx0-101- FS-QS-2xx0-100- FS-QS-2xx0-104-
7100 208 208 208 208 208
Gamewell FIC FS-QS-2xx0-103- FS-QS-2xx0-102- FS-QS-2xx0-101- FS-QS-2xx0-100- FS-QS-2xx0-104-
7200 195 195 195 195 195
FS-QS-2xx0-103- FS-QS-2xx0-102- FS-QS-2xx0-101- FS-QS-2xx0-100- FS-QS-2xx0-104-
Gamewell FIC 7E3
131 131 131 131 131

Hardware Specifications

Ability to interface from 250 to 5000 points.


Non-LonWorks model has 2xRS485 ports,
1xEthernet port.
Protonode series model has 1xRS485 port,
1xLonworks port and 1xEthernet port.
BTL Mark – FS-QS Series
Lon Mark Certified – FS-QS Series
Supports BACnet COV
Power Supply: 24VAC 0.125A
9-30VDC 0.25A @12 VDC

+61 424 706 701


www.protoconvert.com.au
Silent Knight

The Silent Knight Gateway Command (SKgwcmd) Driver allows the Field Server to
transfer data to and from devices over either RS-232 or RS-485 using Silent Knight
Gateway Command (SKgwcmd) Driver protocol. The Silent Knight Gateway Command
(SKgwcmd) Driver is based on the protocol specification “Gateway Command Set
Specification 5820 Intellinight System rev D.2 dated 11 July 2000”.
The Silent Knight Gateway Command driver can serve as an active Client as well as
emulate a Silent Knight 5820 device in Server mode.
The Silent Knight unit’s serial port settings are configurable. The Field Server device
can be configured to match all Silent Knight port settings.

BACnet Modbus
BACnet IP Modbus TCP SNMP
MSTP RTU

FS-QS-2xx0-103- FS-QS-2xx0-102- FS-QS-2xx0-101- FS-QS-2xx0-100- FS-QS-2xx0-104-


Silent Knight
167 167 167 167 167

Hardware Specifications

Ability to interface from 250 to 5000 points.


Non-LonWorks model has 2xRS485 ports,
1xEthernet port.
Protonode series model has 1xRS485 port,
1xLonworks port and 1xEthernet port.
BTL Mark – FS-QS Series
Lon Mark Certified – FS-QS Series
Supports BACnet COV
Power Supply: 24VAC 0.125A
9-30VDC 0.25A @12 VDC

+61 424 706 701


www.protoconvert.com.au
Media Converter

Fiber Optics to Lonworks


Our LonWorks to Fiber optic converters can be used to interconnect two LonWorks
FT-T10 networks or devices over a long distance. Our converters can be used as peer-
peer modems or in a multi drop type network architecture. Depending on the type of
Fiber (multi-mode or single mode), distance and network topology we have the
following models available.

No Of Max Distance Connection


Model Description Fiber Type
Fibers Between FO Nodes Topology

Point to point Link,


HFB-FO-LON-P2S Single Mode 2 20 Kms Peer To Peer
Dual Fiber, 20km

Point to point Link,


HFB-FO-LON-P2M Multi-Mode 2 2 Kms Peer To Peer
Dual Fiber, 2km

Multi point Bus Link,4


HFB-FO-LON-R4S Single Mode 4 20 Kms Multi Drop Bus/
Fiber, 20km
Ring Topology

Multi point Bus Link,4


HFB-FO-LON-R4M Multi-Mode 4 2 Kms Multi Drop Bus/
Fiber, 2km
Ring Topology

Fiber Optics to RS485


Our RS-485 to Fiber optic converters can be used to interconnect two RS-485
networks or devices over a 485 distance.

No Of Max Distance Connection


Model Description Fiber Type
Fibers Between FO Nodes Topology

Point to point Link,


HFB-FO-485-P2S Single Mode 2 20 Kms Peer To Peer
Dual Fiber, 20km

Point to point Link,


HFB-FO-485-P2M Multi-Mode 2 2 Kms Peer To Peer
Dual Fiber, 2km

Multi point Bus Link,4 Multi Drop Bus/


HFB-FO-485-R4S Single Mode 4 20 Kms
Fiber, 20km Ring Topology

Multi point Bus Link,4 Multi Drop Bus/


HFB-FO-485-R4M Multi-Mode 4 2 Kms
Fiber, 2km Ring Topology

+61 424 706 701


www.protoconvert.com.au
Fiber Optics to RS232
Our RS-232 to Fiber optic converters can be used to interconnect two RS-232
networks or devices over a 232 distance.

Max Distance
Connection
Model Description Fiber Type No Of Fibers Between FO
Topology
Nodes

Point to point Link,


HFB-FO-232-P2S Single Mode 2(Tx And Rx) 20 Kms Peer To Peer
Dual Fiber, 20km

Point to point Link,


HFB-FO-232-P2M Multi-Mode 2 (Tx And Rx) 2 Kms Peer To Peer
Dual Fiber, 2km

4(Tx Rx From
Multi point Bus Link,4 Previous Node and Multi Drop Bus/
HFB-FO-232-R4S Single Mode 20 Kms
Fiber, 20km Tx Rx Going to Ring Topology
Following Node)
4(Tx Rx From
Multi point Bus Link,4 Previous Node and Multi Drop Bus/
HFB-FO-232-R4M Multi-Mode 2 Kms
Fiber, 2km Tx Rx Going To Ring Topology
Following Node)

Fiber Optics to CAN and Device net


We have CAN to Fiber Optics converter with model no: FO-FIB-100PT point to point
dual Fiber, single or multi-mode.
The units support CAN 1.0 and CAN 2.0 CAN standards and Device Net

Model Description Port No. Fiber Mode Fiber Connector

Configurable Fiber Optic


FO-FIB-100PT Converter, Point to Point 1CAN+2 or 4 FO Single/Multi Mode ST/SC/FC
Link, Wall Mount
Configurable Fiber Optic
FO-FIB-100BT Converter, Multi Drop Link, 1CAN+4 or 8 FO Single/Multi Mode ST/SC/FC
Wall Mount

+61 424 706 701


www.protoconvert.com.au
Fiber Optics to Profibus DP

Our Profibus DP to Fiber optic converters can be used to interconnect Profibus Serial
Interfaces over a long distance.

Our converters can be used as peer-peer modems or in a multi drop type network
architecture.

Depending on the type of Fiber (multi-mode or single mode), distance and network
topology we have the following models available.

Max Distance
Connection
Model Description Fiber Type No Of Fibers Between FO
Topology
Nodes

Point to point Link,


HFB-FO-PRO-P2S Single Mode 2(Tx And Rx) 20 Kms Peer To Peer
Dual Fiber, 20km

HFB-FO-PRO- Point to point Link,


Multi-Mode 2 (Tx And Rx) 2 Kms Peer To Peer
P2M Dual Fiber, 2km

4(Tx Rx From
Multi point Bus Link,4 Previous Node and Multi Drop Bus/
HFB-FO-PRO-R4S Single Mode 20 Kms
Fiber, 20km Tx Rx Going to Ring Topology
Following Node)
4(Tx Rx From
HFB-FO-PRO- Multi point Bus Link,4 Previous Node and Multi Drop Bus/
Multi-Mode 2 Kms
R4M Fiber, 2km Tx Rx Going To Ring Topology
Following Node)

+61 424 706 701


www.protoconvert.com.au
RS-485 HUB (Model No: I7514U-G CR)

The I-7514U is a 4-ch RS-485 active star wiring hub, it has 4 independent RS-485
output channels and one RS-485 input channel. Each output channel is equipped with
an individual driver. The data from a master to the input channel will simultaneously
be forwarded to all the four output channels.
Supports
Auto Switching baud rate, 300 ~ 115200 bps and fixed baud rate setting via rotary
switch, 1200 ~ 115200 bps
120Ω termination resistor for each channel
Power Input, +10 ~ +30 VDC
DIN Rail
RS-485 HUB (Model No: I7520U4-G CR)

The I-7520U4 is isolated RS-232 to 4-ch RS-485 active star wiring hub, it has 4
independent RS-485 output channels and one RS-232 input channel.

Self-Tuner baud rate, 300 ~ 115200 bps and fixed baud rate setting
LEDs for indicating Tx D/Rx D activity.
via rotary switch, 1200 ~ 115200 bps
120Ω termination resistor for each channel
Power Input, +10 ~ +30 VDC
Operating Temperatures, -25 °C ~ +75 °C
DIN-Rail
Individual Channel Configuration

Isolated RS-232 to RS-485 Converter (RoHS) (Model No: I-7520 CR)

Transmission Speed of up to 115200 bps


ESD Protection for the RS-232/422/485 Data Line
Power Input of +10 ~ +30 VDC
Supports Operating Temperatures from -25 °C ~ +75 °C
DIN-Rail

+61 424 706 701


www.protoconvert.com.au
16 Channel Isolated Digital Input to Modbus RTU Converter (Model No: M-7051-G CR)

The M-7051 offers 16 channels for digital input, catering for both dry and wet contact,
with an effective distance for dry contact of up to 500 meters.
Interface: RS-485
Protocol Supports: Modbus RTU
Baud Rate: 1200 to 115200 bps

10 Differential/ 20 Single-ended Analog Inputs to Modbus RTU Converter (model No: M-


7017Z)

The I-7017Z is an Analog Input module that includes 10 differentials or 20 single-ended


Analog Input channels. The module provides a programmable input range on all
Analog Input channels.

Features:
10-channel Differential or 20-channel Single-ended
inputs
Jumper Selectable Voltage or Current Input
240 Vrms Overvoltage Protection
Supports Fast and Normal Mode Sampling
4 kV ESD and EFT Protection
3000 VDC Intra-module Isolation
Overcurrent Protection
Dual Watchdog
Wide Operating Temperature Range: -25 to +75°C

+61 424 706 701


www.protoconvert.com.au
·

16 Channel Non-Isolated Digital Output to Modbus Converter (Model No: M-7043 CR)

The M-7043 offers 16 digital output channels, each of which are non-isolated and
support sink-type output using an open collector. There are also options to enable
both power-on and safe values. It supports Modbus RTU protocol.

Mbus Master (RS232 or RS485)


M-Bus Master is dedicated to convert M-Bus signal to RS232/RS485 and vice versa. Up
to 250 M-Bus slave devices can be connected to M-Bus Master.

Features
RS485: Automatic chose of direction, max 32 transvers, speed up to 9600 bods
RS232: Up to 15m, speed up to 9600 bods
MAX amount of Mbus devices: 250 (375ma)
Mbus short connection protection: yes
Power supplier: 90-250V ~, 50-60Hz
Mounting type: on DIN rail

+61 424 706 701


www.protoconvert.com.au
IIoT Solutions

Modbus/BACnet Datalogger

Our datalogger is an embedded remote monitoring and control solution for Modbus
RTU /Modbus TCP/BACnet MSTP/BACnet IP devices. This unit can connect with
Modbus RTU /Modbus TCP/BACnet MSTP/BACnet IP based field slave devices (on
RS232 or RS485) and present their data on a tabular dashboard for monitoring. It is
also possible to send back commands from the dashboard to control the field
devices.
The device has an onboard MySQL data base, and it is possible to store up to 100,000
values. The stored values can be retrieved in .csv file format.

Model Number:
Modbus RTU Datalogger: PG702X-100 with DL
Modbus TCP Datalogger: PG702X-101 with DL
BACnet MSTP Datalogger: PG702X-102 with DL
BACnet IP Datalogger: PG702X-103 with DL

Modbus-BACnet-SNMP to MQTT Gateway

This gateway enables exchange of data between a BACnet MSTP/BACnet IP/Modbus


RTU/Modbus TCP/SNMP system and an MQTT based system. This gateway can be
configured to read data from a BACnet IP device and then publish it on MQTT.

Model Number:
Modbus RTU - MQTT: PG702X-100-121
Modbus TCP - MQTT: PG702x-101-121
BACnet MSTP - MQTT: PG702x-102-121
BACnet IP - MQTT: PG702x-103-121
SNMP - MQTT: PG702x-104-121

+61 424 706 701


www.protoconvert.com.au
Modbus to XML, CSV, HTTP, JSON

Supports Modbus RTU on RS485 and RS232, Modbus TCP. This gateway acts as a
Modbus Master and can be configured to gather Modbus data from field devices and
publish it as XML, CSV, HTTP, JSON format which you can use for your any API.

BACnet to XML, CSV, HTTP, JSON

Supports BACnet MSTP on RS485, BACnet IP. Gateway acts as a BACnet Master and
can be configured to gather BACnet data from field devices and publish it as XML,
CSV, HTTP, JSON format which you can use for your any API.

SNMP to XML, CSV, HTTP, JSON

Gateway acts as a SNMP Master and can be configured to gather SNMP data from
field devices and publish it as XML, CSV, HTTP, JSON format which you can use for
your any API.

Modbus to Email/SMS

Supports Modbus RTU on RS485 or RS232 and Modbus TCP. Gateway can be
configured as a Modbus Master to collect data from Field Devices using Modbus RTU
or Modbus TCP protocols. SMS and Email alerts can be set on the configured Modbus
data points.

BACnet to Email/SMS

Supports BACnet MSTP on RS485 and BACnet IP. This gateway can be configured as a
BACnet Master to collect data from Field Devices using BACnet MSTP or BACnet IP
protocols. SMS and Email alerts can be set on the configured BACnet data points.

SNMP to Email/SMS

This gateway can be configured as a SNMP Master to collect data from Field Devices
using SNMP protocols. SMS and Email alerts can be set on the configured SNMP data
points.
+61 424 706 701
www.protoconvert.com.au
ProBoard

ProtoConvert Web SCADA software enables you to visualize and record data from
your assets. It is also possible to send control commands back to your assets.
The software is feature rich allowing creating of users, assets and dashboards.

The software can run on Windows or Linux based operating systems. And unless
specified otherwise it generally relies on ProtoConvert IoT gateways for data.

+61 424 706 701


www.protoconvert.com.au
ProBoard+

ProtoConvert Web SCADA software enables you to visualize and record data from
your assets. It is also possible to send control commands back to your assets.

The software is feature rich allowing creating of users, assets and dashboards.

The software can run on Windows or Linux based operating systems. And unless
specified otherwise it generally relies on ProtoConvert IoT gateways for data.

+61 424 706 701


www.protoconvert.com.au
ProtoSoft

ProtoConvert 'ProtoSoft' is a solution for remote monitoring and controlling of field


equipment that use to communicate on either BACnet IP or Modbus TCP/IP.
The objective of this solution is to enable remote monitoring and control of field
equipment from any location using a web browser.
This SCADA can connect with filed devices through the Converter and present their
data on a tabular dashboard for monitoring.
Web-SCADA uses a combination of hardware and software to achieve objectives.

Solution Availability

ProtoSoft PG-702x

Pro Board PG-702x,


Local Server and
Pro Board+ on Cloud

+61 424 706 701


www.protoconvert.com.au
Our Presence

AUSTRALIA
Suite 15 C4 Level 1, sales@protoconvert.com
2 Main Street, +61 (0) 424 706 701
Point Cook protoconvert-sales
Victoria 3030

INDIA
"KEDAR" sales@protoconvert.com
Royal Park street no. 8
+91 95102 38954
University Road,
Rajkot - 360005 protoconvert-sales

USA
3028 sales@protoconvert.com
Greenmount Ave#2065 +1 888 793 0418
Baltimore, protoconvert-sales
MD 21218

+61 424 706 701


www.protoconvert.com.au