The document discusses AB Dental's I-ON conical platform implant system. It was developed to simplify and optimize a dentist's work. The implant system features a hybrid conical platform combining internal and external connections for stability and sealing. It offers advantages like bacterial sealing and platform switching for esthetic results.

Uploaded by

Yair
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
195 views29 pages

Conical Platform Implant

The document discusses AB Dental's I-ON conical platform implant system. It was developed to simplify and optimize a dentist's work. The implant system features a hybrid conical platform combining internal and external connections for stability and sealing. It offers advantages like bacterial sealing and platform switching for esthetic results.

Uploaded by

Yair
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Conical platform

implant
Superior Implant Technology
4

CONTENT AB Dental’s vision


AB DENTAL’S VISION ............................................................................................................ 05 AB Dental’s Implants have been in clinical use for 25 years. That’s 25 years of holding
up to the highest standards of production quality, 25 years of life-changing dental
I-ON CONICAL PLATFORM IMPLANT ............................................................................ 06
treatment for patients all around the world.
I-ON VIRTUES .......................................................................................................................... 07
The choices of dentists around the world are what move us, at AB Dental, to continue
HYBRID CONICAL PLATFORM............................................................................................ 08 to passionately innovate for you. New, high quality solutions to address all your
professional needs, while maintaining the company values.
I-ON ADVANTAGES.................................................................................................................. 10
The I-ON conical platform implant system has been developed especially for you, to
SOFT TISSUE MANAGEMENT............................................................................................. 12 simplify and optimize your work.
NOVEL BIOMIMETIC SURFACE TREATMENT ............................................................. 14 I-ON implants, as all AB Dental products, are held up to quality management systems
I-ON SIZES ................................................................................................................................ 16 ISO & MDSAP, quality management for medical devices and Medical Device Directive.

DRILL PROTOCOL .................................................................................................................. 18

TOOLS: ........................................................................................................................................ 19 The products’ availability may vary between countries according to each local regulatory
approval.
Drills ........................................................................................................................................... 20
Tools ........................................................................................................................................... 22 Our instructions for use are available at: [Link]/ifu
TKS-SD-CP Surgical Kit ............................................................................................................. 23 This content is available for free download and view using Adobe Acrobat Reader
application, download here.
TKM-T8C-SD-CP Surgical Kit .................................................................................................... 24

PROSTHETIC PARTS: ............................................................................................................ 26


Index chart ................................................................................................................................. 28
Healing cap matching ................................................................................................................ 30
Healing cap ................................................................................................................................ 32
Impression ................................................................................................................................. 33
Cement Retained Restoration .................................................................................................... 35
Screw Retained Restoration ...................................................................................................... 41
Overdenture Restoration ............................................................................................................ 49
CAD/CAM ...........................................................................................................................39,43,46

INDEX .......................................................................................................................................... 52

AB Dental Devices' products are cleared for marketing by the FDA and are CE-marked in accordance with the Council Directive 93/42/EEC and Amendment 2007/47/EC.
The products availability may vary between countries according to each local regulatory approval.
AB Dental Devices complies with EN ISO 13485:2016 and Australia - Therapeutic Goods (MD) Regulations, the Canadian Medical Devices Regulations - SOR 98/282, USA -
21 CFR 820, 21 CFR 806, 21 CFR 807 (A-D).

© All rights reserved


6 7

Conical
platform
implant
For long-term
successful, I-on implant packages
stable and will be identified by
dark blue color
esthetic
results
VIRTUES
+ Perfect design, for optimal esthetic results

+ Excellent bacteria sealed implant-abutment interface

+ Stable and strong implant-abutment connection

+ Unified physical platform-shifting for all diameters

+ Comprehensive prosthetic line for all diameters 3.5-5 mm

+ Top class design for the professional high-end user


8 9

14º internal cone

HYBRID CONICAL PLATFORM


The hybrid conical platform combines
2.1mm Internal Hexagon
internal and external connections.
The internal connection is comprised
of a 14° conical platform,
and a 2.1 mm HEX. 14°
The platform angle Flat surface
allows optimal
bacterial seal between
implant and abutment,
keeping the interface
area distant from the
tissues.
Small angle chamfer
Precise implant-
abutment fit provides
high mechanical stability and stress
distribution. The external most coronal portion of the implant is comprised of a flat
surface and a small angle chamfer, to allow external connection of rotational
(non-engage) products.
2.1mm HEX
Prosthetic products were developed so that they engage all the implant’s
inner cone, to assure interface seal and optimal load distribution.

The narrow emergence profile leaves space for soft tissues, allowing for
greater platform switching and better gingival sealing.

However, temporary restoration parts (such as healing caps, transfers, etc.)


are designed to attach to the implant cone or to the external features, for fast
and easy removal.
10 11

advantages Anatomical design:


All I-ON abutments are
designed to continue the
Excellent Bacterial inner cone, giving the
seal:
Platform switching: rehabilitation a more
The inner incline cone of the natural look and a natural
Restoration of implants implant platform provides emergence profile.
with diameter- super-tight implant-abutment
reduced interface.
abutments,
for improved Gingiva Abutment
preservation
of crestal bone
levels and
Bone Implant
increasing
the soft
tissue volume
Back-taper concave
contributes
neck design:
to long-term To reduce pressure on the
esthetic outcomes. cortical bone, to enable good
blood supply and reduce
bone absorption.
Neck Rings:
Increase surface
area, thus enabling
large BIC (Bone-to-
implant connection)
and provide easy
Blue anodization: identification.
For easy identification
of the I-ON implants.

variable thread:
Apically sharp treads Hybrid Coonical Connection:
that transform and The internal connection is designed
increase coronally with a 14° internal cone and a 2.1 mm
into flat threads, thus hexagon.
enabling 3D strong The external face connection is
initial stability. comprised of a flat surface
surrounded by a small-angle
chamfer.
12 13

Soft tissue management


I-ON implants were developed with
esthetic outcome in mind.

Esthetic results can be achieved by


successful soft tissue management.
I-ON design allows for natural,
esthetic soft tissue forming and
maintenance.

A wide range of temporary


solutions is available for soft tissue
shaping, with emergence profile
identical to the final restorations,
to ensure a consistent process
and maximum predictability of the
esthetic outcome.
14 15

Novel Biomimetic Surface Treatment


AB Dental’s new surface treatment enhances AB Dental has developed a new surface treatment to enhance bone
formation around Ti based implants and improve implant osseointegration.
bone formation around implants and improves This novel surface uses physical and chemical modification methods to
osseointegration. Our physical and chemical create a highly consistent microroughened surface needed to stimulate
modifications create a highly consistent bone formation around the implant.
AB Dental implants undergo a special treatment starting with RBM
microroughened surface needed to stimulate (Resorbable Blast Media) blasting with Biological Calcium-Phosphate
bone formation around the implant. particles for surface roughening and followed by several thermal acid
etching treatments to enhance the implant surface and provide it the
perfect roughness and microstructure. The final highly clean, free of
contaminates, biological surface with high surface area provides direct
attachment of the bone to the implant and promotes fast and optimal
Osseointegration is a tightly Osseointegration.
regulated biological process that Next, the implants are sterilized by Gamma irradiation to ensure optimal
occurs immediately after implant clinical success for patients.
placement. The cells are sensitive to
implant surface properties including A Morphological scanning electron microscopy of the novel biomimetic surface
topography, chemistry, and wettability at macro, micro, and nanoscale show complex roughness at all different level
and respond to these properties by including a Nano roughness (Figure 1).
either creating bone on and around
the inserted implant or by creating a
fibrous collagen tissue resulting in pain
and implant failure. Not all implants
are created equally. Scientific research
has shown that Titanium and Ti alloy
(Ti-6Al-4V ELI) implants that match the
physical topography of bone increase Figure 1: Morphological scanning electron microscopy of the novel biomimetic surface atmacro,
implant integration and reduce healing micro, and nanoscale. 20Kx and 50Kx images show osteoclast like pits on the surface of the
time compared to smooth or machined Ti6Al4V implant surface. 100Kx image shows nanoscale topography like that of collagen fibrils
implants. on a native bone surface.

Reference: Berger MB, Bosh KB, Cohen DJ, Boyan BD, Schwartz Z. Benchtop plasma treatment of titanium surfaces enhances
cell response. Dent Mater. 2021 Apr;37(4):690-700. doi: 10.1016/[Link].2021.01.026. Epub 2021 Feb 13. PMID: 33589272; PMCID:
PMC7981249.
16 17

Sizes
D L Order by
I-ON DIAMETERS (mm) (mm) Cat. No

3.5 10 I10C-3.5,10

11.5 I10C-3.5,11.5

13 I10C-3.5,13

16 I10C-3.5,16

3.75 8 I10C-3.75,8

10 I10C-3.75,10

11.5 I10C-3.75,11.5

13 I10C-3.75,13

16 I10C-3.75,16

4.2 6 I10C-4.2,6 *

8 I10C-4.2,8
3.5 mm 3.75 mm 4.2 mm 5.0 mm
10 I10C-4.2,10

11.5 I10C-4.2,11.5

13 I10C-4.2,13

16 I10C-4.2,16

5.0 6 I10C-5.0,6 *

8 I10C-5.0,8 *

10 I10C-5.0,10

11.5 I10C-5.0,11.5

13 I10C-5.0,13
The inner diameter and design is the same for all implant diameters.
* Coming soon
18 | implant drill protocol Implant drill protocol | 19

IMPLANT DRILL PROTOCOL


I-ON DRILL PROTOCOL
RECOMMENDED DRILL PROTOCOL FOR STRAIGHT OR STEP DRILLS

Drill Diameter (mm)


Drill Speed (RPM)
TMD
Ø 1.9
TPDD
Ø 2.0
1200-1500 900-1200
TDSD
Ø 2.5
800-1000
TDSD
Ø 2.8
500-700
TDSD
Ø 3.2
400-700
TDSD
Ø 3.65
400-600
TDSD
Ø 4.0
400-600
tools
TMD Marker drill bit
TPD Pilot drill bit
TDSD Step drill bit

Implant Bone
Diameter Type

Soft Bone
Ø3.5
Hard Bone
Optional
Soft Bone
Ø3.75
Hard Bone
Optional
Soft Bone
Ø4.2
Hard Bone

Ø5.0 Soft Bone


Hard Bone

Mark drill site


Drill throughout entire implant’s length
Optional – In case TDSD step drill is used
Drill through cortical plate in case
c Drill through cortical plate with Counter Sink drill in case needed

16 mm _
13 mm _
11.5 mm _
10 mm _
8 mm _
6 mm _
20 | Drills drills | 21

PROSTHETIC PARTS INDEX - STANDARD PLATFORM


TOOLS
DRILLS

COATED STEP DRILLS STRAIGHT DRILLS

TDSD-2.5 TD-2.5
ø 2.5 Step Drill Bit ø 2.5 Drill Bit

TDSD-2.8 TD-2.8
ø 2.8 Step Drill Bit ø 2.8 Drill Bit

TDSD-3.2 TD-3.2
TDSD-2.5 ø 3.2 Step Drill Bit TPD-2.0 ø 3.2 Drill Bit
Coated Pilot
Step Drill Bit TD-3.65
TDSD-3.65
Drill Bit ø 3.65 Drill Bit
ø 3.65 Step Drill Bit

TD-4.0
TDSD-4.0 ø 4.0 Drill Bit
16mm ø 4.0 Step Drill Bit 16mm
TD-4.5
13mm
TDSD-4.5 13mm ø 4.5 Drill Bit
11.5mm 11.5mm
ø 4.5 Step Drill Bit
10mm 10mm

8mm 8mm
TDSD-5.0
6mm ø 5.0 Step Drill Bit 6mm

TDSD-5.5
ø 5.5 Step Drill Bit

ADDITIONAL DRILLS

TMD-1.9 TPDD-2.0 TDCS-3.75-4.2


ø 1.9 Marker ø 2.0 Pilot Counter Sink
Drill Bit Drill Bit
22 | TOOLs Surgical kits | 23

PROSTHETIC PARTS INDEX - STANDARD PLATFORM


TOOLS
TOOLS TKS-SD-CP
COMPACT ORGANIZED KIT

IMPLANT DRIVERS RETRIEVAL SCREW


‫‏‬Step drill small Kit

‫ ‏‬idth: 10cm
W
‫‏‬Length: 14.5cm
‫‏‬Height: 6.5cm

T3C-4,9 T3C-4,18 T4C-4


Implant Ratchet Hex Conical Implant
Driver Conical Platform Retrieval Screw

CONTRA ANGLE DRIVERS

T3-2,18
Implant Ratchet Hex Driver TMD-1.9
Narrow Platform ø 1.9 Marker Drill Bit
Implant
T3C-4,9 Ratchet Hex TPDD-2.0
Driver Conical ø 2.0 Pilot Drill Bit
T3C-4,18
T5C-4,25 T5-1.2,21 T5-1.2,26 Platform
Implant Motor Contra Angle Driver for TDSD-2.5
Driver L25mm Abutment Ratchet Hex ø 2.5 Step Drill Bit
T1-1.2,9
Conical Platform Driver for
T1-1.2,15 Abutment TDSD-2.8
ø 2.8 Step Drill Bit
ABUTMENT DRIVERS T2-1.2,9 Hand Hex
Driver for TDSD-3.2
T2-1.2,15 Abutment ø 3.2 Step Drill Bit

T5C-4,25 TDSD-3.65
Implant Motor Driver L25mm ø 3.65 Step Drill Bit
Conical Platform
TDSD-4.0
T8
ø 4.0 Step Drill Bit
T1-1.2,9 T1-1.2,15 T2-1.2,9 T2-1.2,15 Ratchet Wrench
Ratchet Hex Driver for Abutment Hand Hex Driver for Abutment -
TP-23 TDSD-4.5
with friction
Parallel Pin (x2) ø 4.5 Step Drill Bit
24 | Surgical kits Surgical kits | 25

PROSTHETIC PARTS INDEX - STANDARD PLATFORM


TOOLS
TKM-T8C-SD-CP
MEDIUM ORGANIZED KIT WITH STEP DRILLS

‫‏‬Step drill medium Kit DEFAULT CONTENT OPTIONAL PRODUCTS


Max. products within the kit - 34
‫ ‏‬idth: 17.5cm
W TMD-1.9
‫‏‬Length: 19.5cm TDCS-3.75-4.2
ø 1.9 Marker Drill Bit
‫‏‬Height: 6cm Counter Sink

TPDD-2.0 T5-1.2,26
ø 2.0 Pilot Drill Bit
Contra Angle Driver for
Abutment
TDSD-2.5
ø 2.5 Step Drill Bit
TP-17
Parallel Pin
TDSD-2.8
ø 2.8 Step Drill Bit TP-23
Parallel Pin
TDSD-3.2
ø 3.2 Step Drill Bit
T9
Depth Gauge
TDSD-3.65
ø 3.65 Step Drill Bit
T10
Handle
TDSD-4.0
DEFAULT CONTENT ø 4.0 Step Drill Bit
T5-1.2,21
T3-2,9 Implant Ratchet
Contra Angle Driver for TDSD-4.5
Hex Driver Narrow
T3-2,18 Abutment
Platform ø 4.5 Step Drill Bit

Implant T5C-4,25
T3C-4,9 TDSD-5.0
Ratchet Hex Implant Motor Driver L25mm
Driver Conical Conical Platform ø 5.0 Step Drill Bit
T3C-4,18
Platform
TDSD-5.5
T8C-10-40
T1-1.2,9 Ratchet Hex ø 5.5 Step Drill Bit
Ratchet-Torque Combination
Driver for
T1-1.2,15 Abutment TDE
TP-23
Drilling Extension bit
Parallel Pin (x4)
T2-1.2,9 Hand Hex
Driver for
T2-1.2,15 Abutment T5-2,20
Contra Angle Implant Driver
Narrow Platform
PROSTHETIC PARTS CONICAL PLATFORM
28 | PROSTHETIC PARTS INDEX PROSTHETIC PARTS INDEX | 29

PROSTHETIC PARTS INDEX - CONICAL PLATFORM


CONICAL PLATFORM
The order and presentation of these products is based on impressions taken from the implant. Abutment closure torque 30Ncm.
There is also an option to take an impression after connecting the abutment to the implant. Screw retained sleeve closure torque 25Ncm.

Healing caps Transfers / Scan Bodies / Analogs Abutments Abutments / Sleeves / Attachments

Impressions CAD/CAM Temporary Straight Angular Casting CAD/CAM


Cement-Retained
Restoration

D2C-4 P3LC-4,SC P4C-4 P9HRC-4 P3NC-4


Page 33 Page 39 Page 37 Page 38 Page 40

P0C-4 D1C-4 P3SC-4


Page 32 Page 34 Page 36

D2OC-4 D1C-4,MA P4LC-4 P9RC-4 P3NC-4,R


Page 33 Page 39 Page 37 Page 38 Page 40

P0NC-4
Page 32

D2-P14C-4 P14C,SC P14C-4,17 P14C-bT-AR P14C-bTs-C


Screw-retained
Restoration

Page 48 Page 46 Page 42 Page 43 Page 43

POWC-4 P0-P14C D1-P14C-4 P14C-b P16C-4


Page 32 Page 47 Page 45 Page 43 Page 44

D4-P14C D1-P14C,MA P14C-4,30 P14C-bT P14-bTs-AR


Page 48 Page 46 Page 42 Page 43 Page 43

PONNC-4
Page 32
Overdenture
Restoration

P55C-4
Page 50
30 | Healing Cap Matching Healing Cap Matching | 31

PROSTHETIC PARTS INDEX - CONICAL PLATFORM


Healing Cap Matching
Conical platform healing cap emergence profile selection, according to the final abutment:

P0NC-4 P0C-4 P0WC-4 P0NNC-4


CP Healing Cap

CP Healing Cap
4.8 mm 5.3 mm 5.5 mm 5.8 mm 4.4 mm

P0NC-4,1 P0NC-4,2 P0NC-4,3 P0NC-4,4 P0NC-4,5 P0C-4,1 P0C-4,2 P0C-4,3 P0C-4,4 P0NNC-4,2.5 P0NNC-4,3.5 P0NNC-4,2.5 P0NNC-4,3.5 P0NNC-4,2.5 P0NNC-4,3.5

P16C-4,1 P16C-4,2 P16C-4,3 P16C-4,4 P16C-4,5 P3SC-4,1 P3SC-4,2 P3SC-4,3 P3SC-4,4


P4C-4,25 P4LC-4,25 P4LC-4,15 P3NC-4,1.5,R P3NC-4,2.5,R P3NC-4,3.5,R
CP Abutment

CP Abutment
P9HRC-4 P4C-4,15 P14C-4,17-1 P14C-4,17-3
P4C-4,15 P14C-4,17-3 P9RC-4

P4C-4,25 P4LC-4,25 P4LC-4,15 P14C-4,17-2 P14C-4,30-2 P14C-4,17-2 P14C-4,30-2 P9HRC-4

P3NC-4,1.5 P3NC-4,2.5 P3NC-4,3.5 P14C-4,30-1 P14C-4,30-3 P14C-4,30-1 P14C-4,30-3 P3NC-4,1.5 P3NC-4,2.5 P3NC-4,3.5

* CP = Conical Platform
32 | HEALING CAP IMPRESSION TRANSFER | 33
1 2 3 4 5
4 P0C-4 HEALING CAP 5 6 7 D2C-4 IMPRESSION TRANSFER D
D
D
A
Closure on the
A ‫ ‏‬olished Titanium
P
implant most surface for excellent
coronal flat surface, tissue acceptance
AH to seal the implant
connection during
healing period 1 2 3 4 5 6 7
1 2 3 4 5 6 7
Designed for
GH
AB D

D AB accurate open
D

B A A and decisive
A B closed tray A
‫ ‏‬aintains tissue
M
impression
‫‏‏‬Available in opening for
taking

L
various diameters preparing the L
and Gingival heights site for placing
for maximum soft prosthetic device
tissue management, L

L
for perfect and most
accurate emergence B B
VIEW B
B VIEW B B
profile for the final
abutment Slot for easy
C release

SECTION I-I
C

P0C-4
Tolerances:
Linear +- 0.05 P0NC-4
The information contained in this drawing
is the sole property of AB Dental Devices. P0WC-4 P0NNC-4 C C
[Link] Devices LTD. C C
Angular +- 1* Any reproduction in part or as a whole without
Dimensions are the written permission
in millimeters of AB Dental Devices is prohibited.
Healing Cap Narrow Wide Narrow Healing
D D2C-4 D2OC-4
SIGNATURE DATE SPESIFICATION: TITLE:

SECTION A-A
NAME

DRAWN Czeisler A. 08/03/18


A A
SECTION A-A
CHK'D Betzalel M.
Healing cap Healing
Healing Cap GH2mm
Cap D4.8mm
Cap Wider Closure
SECTION D-D
d. AH3mm Conical Platform
D
APPV'D Gur bar-shalom Tolerances: The information containe
is the sole property of AB
x45 PROJ. METHOD:
Surface Impression Impression
Linear +- 0.05
Angular +- 1* Any reproduction in part or
SCALE:
15:1 MATERIAL: DWG NO. Dimensions are the written per
REV. A SCALE 7 : 1
in millimeters of AB Dental Devices
Transfer Transfer
The information contained in this drawing
P0NC-4,2
Tolerances:
WEIGHT: Ti-6Al-4V ELI Tolerances: The information contained in this drawingLinear +- 0.05 is the sole property of AB Dental Devices.
0.37
[Link] Devices LTD.
Linear +- 0.05 is the sole property of AB Dental [Link] +- 1* Any reproduction in part or as a whole without NAME SIGNATURE DATE SP

[Link] Devices LTD.


Angular +- 1* Any reproduction in part or as a whole without
Dimensions are the written permission

4 5 6 7 D Tray
Closed NOTES: Open Tray Dimensions are
in millimeters
the written permission
of AB Dental Devices is prohibited.
in millimeters

D
NAME
of AB Dental Devices is prohibited.
SIGNATURE DATE SPESIFICATION: TITLE:
DRAWN

CHK'D
06/05/2020

D NOTES: 1. Angular, phases and radius are REF unless otherwise stated. D
NAME SIGNATURE DATE SPESIFICATION: DRAWN
TITLE: 06/05/2020

D NOTES:
DRAWN

1. Angular, phases and radius are REF unless otherwiseCHK'D stated.


06/05/2020 CHK'D APPV'D Gur Bar-Shalom

1. Angular, phases and radius are REF unless


2. otherwise
Remove all stated. 2. Remove all burrs 0.03 and
burrs and shrap edges - R0.03 0.02 /APPV'D
shrap edges - R0.03 0.02
0.02 x45
Gur Bar-Shalom / 0.03
APPV'D Gur Bar-Shalom
0.02 x45
PROJ. METHOD:
PROJ. METHOD:

2. Remove all burrs and shrap edges - R0.03


3. 0.02 / 0.03 0.02
Unspecified 3. should
x45
corneres Unspecified
be R0.1 max. corneres should be R0.1 max.
PROJ. METHOD:
SCALE:
20:1 MATERIAL: DWG NO. SCALE:
20:1 MA
3. Unspecified corneres should be R0.1 max.
4. Milling and Hex surfaces
4. oriented
Millingasand
shown.
Hex surfaces oriented 20:1
as shown. [Link]:
SCALE: MATERIAL: DWG NO.
WEIGHT:

4. Milling and Hex surfaces oriented as shown. WEIGHT: REV.


1 2 3 4 5 6 7
SHEET 1 OF 2
Order by Cat. No

1 2 3 1 4 2 5 6 3 7 4 5

Order by Cat. No
SHEET 1 OF 2
SHEET 1 OF 2

P0C-4,1 P0NC-4,1 P0WC-4,2 P0NNC-4,1.5

P0C-4,2 P0NC-4,2 P0WC-4,3 P0NNC-4,2.5

P0C-4,3 P0NC-4,3 P0WC-4,4 P0NNC-4,3.5


D2C-4,9 D2OC-4,9
P0C-4,4 P0NC-4,4
D2C-4,15 D2OC-4,15
P0C-4,5 P0NC-4,5
D1 (mm) = 4.5 D1 (mm) = 4.8
D1 (mm) = 5.3 D1 (mm) = 4.8 D1 (mm) = 5.5, 5.8, 5.8 D1 (mm) = 4.4
L (mm) = 9, 15 L (mm) = 9, 15
AH (mm) = 3 AH (mm) = 3 AH (mm) = 3 AH (mm) = 2.5
GH (mm) = 0.75, 1.75, GH (mm) = 0.75, 1.75, GH (mm) = 1.5, 2.5, 3.5 GH (mm) = 1.3, 2.3, 3.3
2.75, 3.75, 4.75 2.75, 3.75, 4.75
D2 transfers are available with D2a-4 or D2OCal-4 screws.
A short screw for a closed tray and a long screw for an open tray.
D2Ca-4 D2Cal-4 D2OCal-4
34 | ANALOG 35

cement-retained RESTORATION
3 D1C-4
4 ANALOG
5 6 7

A
Cement-Retained RESTORATION
D

Made of Titanium
alloy to allow
preparation of
L laboratory models

D1C-4
Implant Analog
C
Order by Cat. No

SECTION AN-AN

Tolerances: The information contained in this drawing


Linear +- 0.05 is the sole property of AB Dental Devices.

[Link] Devices LTD.


Angular +- 1* Any reproduction in part or as a whole without
Dimensions are the written permission
in millimeters of AB Dental Devices is prohibited.
D1C-4
D
NAME SIGNATURE DATE SPESIFICATION: TITLE:

DRAWN Czeisler A. 08/03/18

D1 (mm) = 3.75
CHK'D Betzalel M. Implant Analog Conical
ed. APPV'D Gur bar-shalom Platfom
02 x45 L (mm) = 12 PROJ. METHOD:

SCALE:
15:1 MATERIAL: DWG NO.

WEIGHT: Ti-6Al-4V ELI D1C-4 REV. A


0.08

3 4 5 6 7
36 | ANTI-ROTATION ABUTMENT ANGULAR ABUTMENTS | 37

cement-retained RESTORATION
1
P3SC-42 3 4 1 1
1 2 2
2 5 3 3
3 6 4 44
1 P4C-47 ANGULAR ABUTMENT 52 5
5 6 6
3 6 7 47
7 5 6 7

ANTI-ROTATION ABUTMENT AA
A
X X
X
A A
A A
AA
X
A A A
A
D
D
D
Also available in
15° and 25°
long abutment
The anatomic anti-
rotation abutment
B
follows the shape of
B gingival
B B B B

LL
B

L
L
the line
L
B

L
B

Straight Titanium
abutment with Hex
Platform switching
by design, allowing
perfect environment
CC D2 D2 C
X D1 D1
D1X D2 D1
C X X D2 for soft-tissue Designed for
growth and helps CC
C restoration on
to prevent bone tilted implants
resorption
SECTION SECTION X-X
D SECTION D-D SECTION X-X X-X
SECTION X-X
C
C
P3SC-4 PK-D2 P4C-4Tolerances: The information
Tolerances:
Tolerances:
Linear +- 0.05
The information
is the contained
contained
sole property of inP4LC-4
The information contained in this drawing
ABthisindrawing
this Devices.
Dental drawing
Tolerances:
Linear +- 0.05
The information contained in this drawing
is the sole property of AB Dental Devices.
1* is the
Anyissole
[Link] Devices LTD. [Link] Device
LinearLinear
+- 0.05+-+-
Angular 0.05 theproperty
sole property
reproduction of
in AB of
Dental
part AB Dental
or as Devices.
Devices.
a whole without Angular +- 1* Any reproduction in part or as a whole without

[Link]
[Link]
Devices
Devices
LTD.
LTD.
Angular +- 1* +-Any
Angular
Dimensions 1* reproduction
are Any reproduction in part
the in or
part
writtenaspermission
or
a whole
as a whole
without
without Dimensions are the written permission
Dimensions
Dimensions
are are in millimeters
in millimeters ofthe
ABwritten
the written
Dental permission
permission
Devices is prohibited. of AB Dental Devices is prohibited.
Anti-rotation Plastic Transfer Long
in millimeters
in millimeters of ABof Dental
AB Dental
Devices
Devices
is prohibited.
is prohibited.
Angular
DD
NAME SIGNATURE DATE SPESIFICATION: TITLE:
NAME SIGNATURE DATE SPESIFICATION: TITLE:

DD D D
NAME NAME SIGNATURE SIGNATUREDATE DATE SPESIFICATION:
SPESIFICATION: TITLE: TITLE:
Czeisler A. 08/03/18
NOTES:
DRAWN

D Angular
Czeisler A. 08/03/18
Abutment NOTES: Angular Abutment 15º C
DRAWN

NOTES:
NOTES: Abutment
1. Angular, phases
DRAWN DRAWN CzeislerCzeisler
A.
Betzalel M.
A.
Angular
Angular
Angular
and radius are REF unless otherwise stated.
CHK'D Abutment
Abutment
Abutment15º15º
08/03/18
08/03/18
15º Conical
Conical
Conical
CHK'D Betzalel M.
Platform
1. 1. Angular, phases
andand radius
areareREF REF unless otherwise stated. BetzalelBetzalel
M. M.
Platform
CHK'D CHK'D APPV'D Gur bar-shalom
[Link],
Angular,
phases
phases and
radius
radius are REF
unlessunless
otherwise
otherwisestated.
stated. Abutment
APPV'D Gur bar-shalom
2. Remove all burrs and shrap edges - R0.03
APPV'D APPV'D
0.02 / 0.03 0.02 x45
Gur bar-shalom
Gur bar-shalom Platform
Platform
2. 2. Remove all
all burrs
andand shrap edges -- R0.030.020.02 // 0.03
0.020.02
x45 x45
PROJ. METHOD:
[Link]
Remove all burrs
burrs and
shrapshrap
edgesedges- R0.03 R0.03 0.02
/ 0.03 0.03 0.02 x45
PROJ. METHOD:

3. Unspecified corneres should be R0.2 max.


PROJ. METHOD:
PROJ. METHOD:

3. 3. Unspecified corneres should be


be R0.2 max. SCALE:
15:1 MATERIAL: DWG NO.
[Link]
Unspecifiedcorneres
corneres
should
should
be R0.2 R0.2
max.
Themax. 4. Milling and Hex surfaces
SCALE:
15:1
oriented
15:1 15:1 as
MATERIAL:

shown.
DWG NO.
information contained in this drawing P4C-4,15
SCALE: SCALE: MATERIAL:
MATERIAL: DWG NO.
DWG NO.
Material <not specified>
[Link].
Tolerances:
4. 4. Milling
andandHexHex surfaces oriented as shown. Material
<not<not specified> P4C-4,15 B B
WEIGHT:
[Link]
Milling and Hex
surfaces
surfaces
oriented
Linearoriented
+- 0.05 as shown.
as shown.
is the sole property of AB Dental Devices. WEIGHT:
WEIGHT:WEIGHT: Material
0.08 Material <not
specified>
specified> P4C-4,15
P4C-4,15 REV. B 0.08

[Link] Devices
2 5LTD.
Angular +- 1* Any reproduction in part or as a whole without 0.08 0.08
14
1 1 2 2 3 3 63 6 747 5 6
Dimensions are the written permission
1 2
in millimeters
3
of AB Dental Devices is prohibited.
4 4 5 5 6 7
D

Order by Cat. No
Order by Cat. No

NAME SIGNATURE DATE SPESIFICATION: TITLE:

D NOTES:
DRAWN

CHK'D
Czeisler A.
Betzalal M.
08/03/18
Anti-rotation Abutment
1. Angular, phases and radius are REF unless otherwise stated. APPV'D Gur bar-shalom Conical Platform
2. Remove all burrs and shrap edges - R0.03 0.02 / 0.03 0.02 x45 PROJ. METHOD:

3. Unspecified corneres should be R0.2 max.


P3SC-4,1 PK-D2 SCALE:
15:1 MATERIAL: DWG NO.

4. Milling and Hex surfaces oriented as shown. WEIGHT: Ti-6Al-4V ELI P3SC-4,2 REV. B
0.23
P3SC-4,2
1 2 3 4 5 6 P4C-4,15
7 P4LC-4,15
P3SC-4,3
P4C-4,25 P4LC-4,25
P3SC-4,4
D1 (mm) = 4.6, 4.2 D1 (mm) = 5.1, 6
D1 (mm) = 5.17 D=7.4 D2 = 4.9, 5.3 D2 = 4.9, 5.6
L (mm) = 5.16 L=10 L (mm) = 9.2, 10 L (mm) = 14, 12.6
LS (mm) = 1, 2, 3, 4

All abutments include P3ac screw. All abutments include P3ac screw.
P3aC P3aC
38 | composed ABUTMENT CAD/CAM products | 39

cement-retained RESTORATION
P9C-4 COMPOSED ABUTMENT CAD/CAM SCAN ABUTMENT
3 4 5 6 7 1 2 3 4 5 6 7

A A
A
These 3D libraries enable Scan portion
Designed for various precise computerized form PEEK
customized lab restorations, planning of the future - high
Allows precise such as screw-retained, restoration performance
location on the cement-retained and biocompatible
implant and easy telescopic crowns or bridges thermoplastic

L
carving
B
L

B
The scanning information Also for intra-
B is used to produce precise oral scanning
restoration on AB implants designed for
using CAD/CAM re-sterilization
Biocompatible
Composed Cobalt-Chrome alloy,
Hex/non-Hex precisely prepared
abutment base to fit the implant
Ls

CAD/CAM technology Titanium alloy


simplifies the work flow, base for visibility
ensuring accuracy, speed on x-rays, to
and patient comfort assure accurate
C D closure to the
implant C
D
C
P3LC-4,SC D1C-4,MA
Long Scan Abutment Digital Model
Tolerances:Analog
The information contained in this drawing
P9HRC P9RC is the sole property of AB Dental Devices.
Linear +- 0.05
Angular +- 1* Any reproduction in part or as a whole without
Dimensions are the written permission [Link] Devices LTD.
SECTION A-A
in millimeters of AB Dental Devices is prohibited.

Cobalt-Chrome Cobalt-Chrome D
NAME SIGNATURE DATE SPESIFICATION: TITLE:

SCALE 10Hex
Tolerances:
: 1 Abutment
The information contained in this drawing
is the sole property of AB Dental Devices. D NOTES:
DRAWN 08/03/18
Long Scan Abutment Conical
Composed Angular +-Composed
Linear +- 0.05
Abutment
[Link] Devices LTD.
CHK'D
1* Any reproduction in part or as a whole without 1. Angular, phases and radius are REF unless otherwise stated.
Dimensions are the written permission
APPV'D Gur bar-shalom Platform
for Crown for Bridge

Order by Cat. No
in millimeters of AB Dental Devices is prohibited. 2. Remove all burrs and shrap edges - R0.03 0.02 / 0.03 0.02 x45 PROJ. METHOD:

D
3. Unspecified corneres should be R0.2 max.
NAME SIGNATURE DATE SPESIFICATION: TITLE: SCALE:
15:1 MATERIAL: DWG NO.
DRAWN

CHK'D
06/05/2020
4. Milling and Hex surfaces oriented as shown. WEIGHT: P3LC-4,SC REV. A
F unless otherwise stated. APPV'D Gur Bar-Shalom

- R0.03 0.02 / 0.03 0.02 x45 1 2 3 4 5 6 7


Order by Cat. No

PROJ. METHOD:

1 max. SCALE:
20:1 MATERIAL: DWG NO.

s shown. WEIGHT: REV.


SHEET 1 OF 1

3 4 5 6 7
P3LC-4,SC D1C-4,MA

SHEET 1 OF 1 D (mm) = 3.7 D (mm) = 3.8


P9HRC-4,11 P9RC-4,11
L (mm) = 10 L (mm) = 11
D1 (mm) = 4.3 D1 (mm) = 4.3 * Includes screw
L (mm) = 11.5 L (mm) = 11.5
LS (mm) = 1.5 LS (mm) = 1.5 The CAD/CAM libraries were validated in the following system: 3Shape, ZirkonZhan, Exocad, DentalWings.
The most updated CAD/CAM products libraries can be downloaded from AB Dental website.

All abutments include P3ac screw. All abutments include P3ac screw.
P3aC P3aC
40 | CAD/CAM products 41

cement-retained RESTORATION
CAD/CAM TITANIUM BASE
1 2 3 4 5 6 7

A A

Screw-retained RESTORATION
These 3D libraries enable AB Dental
precise computerized products have
planning of the future been added to
restoration by scanning the libraries of
the implants and/or a wide range of
abutments of all types companies
L

B The scanning information B


is used to produce precise
restoration on AB implants
Ls

using CAD/CAM

CAD/CAM technology Titanium base


simplifies the work flow, for cementing
ensuring accuracy, speed crowns and
C and patient comfort bridges made
by CAD/CAM C

P3NC P3NC-R Tolerances:


Linear +- 0.05
The information contained in this drawing
is the sole property of AB Dental Devices.

[Link] Devices LTD.


Angular +- 1* Any reproduction in part or as a whole without
Dimensions are the written permission

Ti Base Abutment Ti Base Abutment in millimeters of AB Dental Devices is prohibited.

D
NAME SIGNATURE DATE SPESIFICATION: TITLE:

D NOTES: for Single Crown for Bridge DRAWN

CHK'D
Czeisler A.
Betzalel M.
08/03/18
Ti Base Slim H2.5mm Conical
1. Angular, phases and radius are REF unless otherwise stated. APPV'D Gur bar-shalom Platform
2. Remove all burrs and shrap edges - R0.03 0.02 / 0.03 0.02 x45 PROJ. METHOD:

3. Unspecified corneres should be R0.2 max. SCALE:


15:1 MATERIAL: DWG NO.

4. Milling and Hex surfaces oriented as shown. WEIGHT: Ti-6Al-4V ELI P3NC-4,2.5 REV. A
0.19

1 2 3 4 5 6 7
Order by Cat. No

P3NC-4,1.5 P3NC-4,1.5,R

P3NC-4,2.5 P3NC-4,2.5,R

P3NC-4,3.5 P3NC-4,3.5,R

D (mm) = 4.3 D (mm) = 4.3


L (mm) = 6.2, 7.2, 8.2 L (mm) = 5.6, 6.6, 7.6
LS (mm) = 1.5, 2.5, 3.5 L S (mm) = 1.5, 2.5, 3.5

All abutments include P3ac screw.


P3aC
42 | multi-unit ABUTMENT multi-unit ABUTMENT | 43

PROSTHETIC PARTSRESTORATION
screw-retained
P14C-4 MULTI-UNIT
5
ANGULAR ABUTMENT 6 7

D
A
A

INDEX - STANDARD PLATFORM


Path of Temporary Casting CAD/CAM
insertion is
especially
wide P14C-bT-AR P14C-bT P14Cb P14C-bTs-AR P14C-bTs-C
P14C-4 Anti- P14C-4 P14C-4 Plastic P14C-4 Conical P14C-4 Conical
Anti-Rotation square
design for single crown Rotational Sleeve Bridge Sleeve Adhesive Sleeve Adhesive Sleeve
Available in
restoration SleeveCrown Restoration Crown Restoration Anti-Rotational
B of 17°, 30°
Restoration
Ls

angles Bridge Restoration

Enables restoration on
non-parallel implants
by correcting extreme

Order by Cat. No
angles of implants

C
SECTION J-J
SCALE 15 : 1

Tolerances: The information contained in this drawing


P14C-4,17 P14C-4,30 P14C-4 components
Linear +- 0.05 is the sole property of AB Dental Devices.

[Link]
RetainedDevices
AngularLTD.
Angular +- 1* Any reproduction in part or as a whole without
Dimensions are
in millimeters
the written permission
of AB Dental Devices is prohibited. Angular Screw Screw Retained P14C-bT-AR P14C-bT P14Cb P14C-bTs-AR P14C-bTs-C
Abutment Abutment D
NAME SIGNATURE DATE SPESIFICATION: TITLE:

DRAWN Czeisler A. 08/03/18


CHK'D Betzalel M. Angular Adaptor Conical D (mm) = 5.1 D (mm) = 5.1 D (mm) = 5.1 D (mm) = 5.1 D (mm) = 5.1
APPV'D Gur bar-shalom Platform 17°-2
PROJ. METHOD:
L (mm) = 11 L (mm) = 11 L (mm) = 11 L (mm) = 5.2 L (mm) = 4.9
SCALE:
15:1 MATERIAL: DWG NO.

WEIGHT: Ti-6AL-4V ELI P14C-4,17-2 REV. B


0.16
P64c
Order by Cat. No

5 6 7

P14C-4,17-1 P14C-4,30-1 P14C-4e

P14C-4,17-2 P14C-4,30-2

P14C-4,17-3 P14C-4,30-3
170 300
P14C-4
D1 (mm) = 4.6 D1 (mm) = 4.6
Ls (mm) = 1, 2.1, 3.2 LS (mm) = 0.9, 2, 3.2

P14C-4 angular abutment includes P64c screw. All sleeves include a P14C-4a screw.
P14C-4e P64c P14C-4-D2a P14C-4a
44
2 | multi-unit ABUTMENT
3 4 5 6 7 ANALOG | 45

PROSTHETIC PARTSRESTORATION
screw-retained
P16C-4 MULTI-UNIT D1-P14C MULTI-UNIT ANALOG
1 2 3 41 52 63 7 4 5 6
STRAIGHT ABUTMENT E
D
A
E
D

A A A A
D D

INDEX - STANDARD PLATFORM


The upper cone The impression-taking
solves the lack of is performed over the
parallelism installed adaptors
Made of Titanium
L alloy to allow
B preparation of

Ls
B B laboratory models
B
The new product design
The over denture allows for a greater space

L
system is screwed for the gums
to the cone.
Available in
different heights

Facilitates the installation


of an over denture system
on nonparallel implants
C C
C

C
A
P16C-4 SECTION A-A P16C-4 components E
Tolerances:
Linear +- 0.05
The information contained in this drawing
SECTION E-Eis the sole property of AB Dental Devices. E
Tolerances:
Linear +- 0.05
The information contained in this drawing
SECTION E-E
is the sole property of AB Dental Devices.

D1-P14C [Link] Devices LTD. [Link] Devi


Angular +- 1* Any reproduction in part or as a whole without Angular +- 1* Any reproduction in part or as a whole without
Dimensions are the written permission Dimensions are the written permission
in millimeters of AB Dental Devices is prohibited. in millimeters of AB Dental Devices is prohibited.

Straight Screw Retained NAME SIGNATURE DATE SPESIFICATION: TITLE:

D
NAME SIGNATURE DATE SPESIFICATION: TITLE:

D NOTES: D NOTES: DRAWN Czeisler A. 08/03/18


P14C-4 Analog
DRAWN Czeisler A. 08/03/18
P14C-4 Ana
Abutment 1. Tolerances:
Angular, phases and radius contained
The information are REF unless
in thisotherwise
drawing stated.
Implant
CHK'D
1. Angular,
Betzalel M.
phases
APPV'D Gur bar-shalom
Analog
and radius are REF unless otherwise stated.
CHK'D

APPV'D
Betzalel M.
Gur bar-shalom

Remove
2. Linear +- 0.05 all burrs
is theand
soleshrap edges
property of AB- R0.03 0.02 / 0.03 0.02 x45
Dental Devices. 2. Remove all burrsPROJ. and shrap edges - R0.03 0.02 / 0.03 0.02 x45
P14C-4a METHOD: PROJ. METHOD:

[Link] Devices LTD.


Angular
[Link] +- 1*
Unspecified Any reproduction in part
corneres should be R0.2 [Link] as a whole without 3. Unspecified corneres should be R0.2
MATERIAL: max.
are
SCALE:
15:1 DWG NO. SCALE:
15:1 MATERIAL: DWG NO.
the written permission
4. in millimeters
Milling and Hex surfaces oriented asisshown. 4. Milling and Hex surfaces oriented Ti-6AL
as shown.4V ELI D1-P14C REV. A Ti-6AL 4V ELI D1-P14C

Order by Cat. No
of AB Dental Devices prohibited. WEIGHT:
0.16
WEIGHT:
0.16

D
NAME SIGNATURE DATE SPESIFICATION: TITLE:

DRAWNCzeisler1 A. 2
06/05/2020 3 4 1 5 2 6 3 7 4 5 6
CHK'D Betzalel M. Straight Adaptor H3
phases and radius are REF unless otherwise stated. Conical Platform
Order by Cat. No

APPV'D Gur Bar-Shalom

all burrs and shrap edges - R0.03 0.02 / 0.03 0.02 x45 PROJ. METHOD:

ed corneres should be R0.1 max. SCALE:


20:1
P14C-a
MATERIAL: DWG NO.

nd Hex surfaces orientedP16C-4,1


as shown. WEIGHT: Ti-6Al-4V ELI P16C-4,X REV. B
D1-P14C
0.24 SHEET 1 OF 1
P16C-4,2
2 3 4 5 6 7
D1 (mm) = 4.6
P16C-4,3 L (mm) = 14.2

P16C-4,4 P16C-4 SHEET 1 OF 1

P16C-4,5
D1 (mm) = 4.6
LS (mm) = 1, 2, 3, 4, 5

P16C-4 straight abutment is provided with P14C-a


carrier and P14a screw.
P14C-4a P16Ca-4
A
46 | CAD/CAM products Healing Cap | 47

PROSTHETIC PARTSRESTORATION
screw-retained
3
CAD/CAM COMPONENTS 4
Transfer to production
approval
5 6 7 F
P0-P14C-4 HEALING CAP F

Sign: ___________ Date: ________


A
D B
These 3D libraries enable Scan portion
precise computerized form PEEK ‫ ‏‬olished Titanium
P

INDEX - STANDARD PLATFORM


planning of the future - high ‫‏‏‬Available in surface for excellent
restoration performance three diameters: tissue acceptance
biocompatible standard, narrow
thermoplastic and wide
B
L

The scanning information Also for intra-

L
is used to produce precise oral scanning
restoration on AB implants designed for
using CAD/CAM re-sterilization C ‫ ‏‬aintains tissue
M
opening for
preparing the
site for placing
CAD/CAM technology Titanium alloy prosthetic device
simplifies the work flow, base for visibility
ensuring accuracy, speed Cx-rays, to
on
D
and patient comfort assure accurate
closure to the Tolerances: The information contained in this drawing
implant Linear +- 0.05 is the sole property of AB Dental Devices.

[Link]
Angular +- 1* Any reproduction in part or as a whole without
SECTION F-F Dimensions are
in millimeters
the written permission
SCALE 15 : 1 of AB Dental Devices is prohibited.
NAME SIGNATURE DATE SPESIFICATION: TITLE:

P14C,SC D1-P14C,MA
Tolerances:
Linear +- 0.05
The information contained in this drawing
is the sole property of AB Dental Devices.
D DRAWN

CHK'D
Czeisler A.
Betzalel M.
29/07/2021
P14
[Link] Devices LTD.
Angular +- 1* Any reproduction in part or as a whole without
Dimensions are the written permission ITEM NO. PART NUMBER DESCRIPTION Specification QTY. APPV'D Gur Bar-Shalom

Scan Body
in millimeters of AB Dental Devices is prohibited.

Digital Model Analog


NAME SIGNATURE DATE SPESIFICATION: TITLE:

D 1 P0-P14C-4 Body P0-P14C-4 P14C Healing Cap Body Blue Anodize Color 1
PROJ. METHOD:

DRAWN Czeisler A. 12/05/2021 SCALE:


12:1 MATERIAL: DWG NO.
P14C-4 Scan Body Healing Cap Screw for Angular
P0
Betzalel M.
2 P0-P64a Screw N/A 1
CHK'D

Adaptor
WEIGHT:
P14C-4
APPV'D Gur Bar-Shalom

PROJ. METHOD:
or 100% of quantity.
Healing Cap
ed in relation to base rectangular reference plane as shown.
SCALE:

WEIGHT:
10:1

0.29
Model analog
MATERIAL:

for digital
DWG NO.

P14C,SC REV. A 1 2 3 4 5 6
printed model
Order by Cat. No

3 4 5 6 7

Order by Cat. No
manufacturing

Two-Piece
design for
precise
positioning P0-P14C-4
D1 (mm) = 4.6
P14C,SC D1-P14C,MA
L (mm) = 4.75
D (mm) = 5.1 D (mm) = 4.6
L (mm) = 9 L (mm) = 14.9
* Includes screw

The CAD/CAM libraries were validated in the following system: 3Shape, ZirkonZhan, Exocad, DentalWings.
The most updated CAD/CAM products libraries can be downloaded from AB Dental website.

All abutments include P3ac screw.


Model Analog includes screw.
P3aC P14C-4a
48 | IMPRESSION TRANSFER 49

overdenture RESTORATION
D2-P14C
T
24 23 22

IMPRESSION TRANSFER
21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

Overdenture RESTORATION
R R

P P

N N

M M

Available for open tray


L - sharp edges & long L

screw, and closed tray


K
- round edges & short K

screw
L

J J

H H

G G

Suitable for bridges


and crowns
F F

E
D E

D D

D2-P14C D4-P14C C

A view to the inner


B
Impression Plastic Snap connection area B

Transfer Open Transfer Kit UNLESS OTHERWISE SPECIFIED:


DIMENSIONS ARE IN MILLIMETERS
SURFACE FINISH:
TOLERANCES:
LINEAR:
FINISH: DEBURR AND
BREAK SHARP
EDGES
DO NOT SCALE DRAWING REVISION

Tray P14C-4 for P14C-4


ANGULAR:

NAME SIGNATURE DATE TITLE:

A A
DRAWN

CHK'D

APPV'D

MFG
MATERIAL: DWG NO.

Assem1
Q.A
A0

WEIGHT: SCAL[Link] SHEET 1 OF 1

24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
Order by Cat. No

D2-P14C-4 D4-P14C
D1 (mm) = 3.8 D1 (mm) = 3.8
L (mm) = 9 L (mm) = 15

The D2-P14C set contains : PK-D2 Transfer (3 units),


and a P14C-4 screw-retained abutment (Multi-Unit).

D2-P14C transfers is available with D2a-P14a screw.


D2-P14a
50 | straight ABUTMENT 51

overdenture RESTORATION
5 P55C-4 AB LOC ATTACHMENT 6 7

An innovative
extremely wide
overdenture
attachment system
for easy connection
L

between the denture Assembled with the


B
and the implants regular abutment
driver

The reduced height


enables the dentist to
place an overdenture
even in cases of reduced
interocclusal space
C

Tolerances:
Linear +- 0.05
The information contained in this drawing
is the sole property of AB Dental Devices.
P55C-4
SECTION I-I
SCALE 15 : 1
P25b/10set P25b/20set Related Parts
[Link] Devices LTD.
Angular +- 1* Any reproduction in part or as a whole without
Dimensions are the written permission
in millimeters of AB Dental Devices is prohibited.

AB LOC (sold Silicon Cap D Silicon Cap


NAME SIGNATURE DATE SPESIFICATION: TITLE:

DRAWN Czeisler A. 08/03/18


Betzalel M. AB LOC H4mm Conical
with transparent Platform(sold as a set of 5) (sold as a set of 5)
CHK'D

APPV'D Gur bar-shalom

silicon cap)
PROJ. METHOD:

SCALE:
15:1 MATERIAL: DWG NO.

WEIGHT: Ti-6Al-4V ELI P55C-4,4 REV. B


0.27

5 6 Yellow
7 Yellow P25a
P55C-4,1
Eextra soft Eextra soft Metal Cap

Pink Pink D = 5.4


P55C-4,2
Soft Soft H=2
Order by Cat. No

Purple Purple
P55C-4,3
Strong Strong

Transparent Transparent P25d


P55C-4,4
Standard Standard Protective Disk

Black Black D = 14
P55C-4,5
For lab For lab

P55C-4,6

D1 (mm) = 3.9
L (mm) = 1,2,3,4,5, 6
52 | Index Index | 53

PROSTHETIC PARTS INDEX - STANDARD PLATFORM


index
INDEX - ORDER BY CAT. NO.
P0C-4,1 32 P16C-4,4 44 T2-1.2,9 22 TP-17 25
CAT No. Page
P0C-4,2 32 P16C-4,5 44 T3-2,18 22 TP-23 23

D1C-4 34 P0C-4,3 32 P3LC-4,SC 39 T3-2,9 22 TPDD-2.0 21

D1C-4,MA 39 P0C-4,4 32 P25-a,b/10 50 T3C-4,18 22

D1-P14C 45 P0C-4,5 32 P25-a,b/20 50 T3C-4,9 22

D1-P14C,MA 46 P0NC-4,1 32 P3NC-4,1.5 40 T4C-4 22

D2C-4,15 33 P0NC-4,2 32 P3NC-4,1.5,R 40 T5-1.2,21 22

D2C-4,9 33 P0NC-4,3 32 P3NC-4,2.5 40 T5-1.2,26 22

D2OC-4,15 33 P0NC-4,4 32 P3NC-4,2.5,R 40 T5-2,20 22

D2OC-4,9 33 P0NC-4,5 32 P3NC-4,3.5 40 T5C-4,25 22

D2-P14C-4 48 P0NNC-4,1.5 32 P3NC-4,3.5,R 40 T8 23

D4-P14C 48 P0NNC-4,2.5 32 P3SC-4,1 36 T8C-10-40 24

I10C-3.5,10 17 P0NNC-4,3.5 32 P3SC-4,2 36 T9 25

I10C-3.5,11.5 17 P0-P14C-4 47 P3SC-4,3 36 TD-2.5 21

I10C-3.5,13 17 P0WC-4,2 32 P3SC-4,4 36 TD-2.8 21

I10C-3.5,16 17 P0WC-4,3 32 P4C-4,15 37 TD-3.2 21

I10C-3.75,10 17 P0WC-4,4 32 P4C-4,25 37 TD-3.65 21

I10C-3.75,11.5 17 P14C,SC 46 P4LC-4,15 37 TD-4.0 21

I10C-3.75,13 17 P14C-4,17-1 42 P4LC-4,25 37 TD-4.5 21

I10C-3.75,16 17 P14C-4,17-2 42 P55C-4,1 50 TDCS-3.75-4.2 21

I10C-3.75,8 17 P14C-4,17-3 42 P55C-4,2 50 TDE 25

I10C-4.2,10 17 P14C-4,30-1 42 P55C-4,3 50 TDSD-2.5 20

I10C-4.2,11.5 17 P14C-4,30-2 42 P55C-4,4 50 TDSD-2.8 20

I10C-4.2,13 17 P14C-4,30-3 42 P55C-4,5 50 TDSD-3.2 20

I10C-4.2,16 17 P14C-b 43 P55C-4,6 50 TDSD-3.65 20

I10C-4.2,6 17 P14C-bT 43 P9HRC-4,11 38 TDSD-4.0 20

I10C-4.2,8 17 P14C-bT-AR 43 P9RC-4,11 38 TDSD-4.5 20

I10C-5.0,10 17 P14C-bTs-AR 43 PK-D2 36 TDSD-5.0 20

I10C-5.0,11.5 17 P14C-bTs-C 43 T10 25 TDSD-5.5 20

I10C-5.0,13 17 P16C-4,1 44 T1-1.2,15 22 TKS-SD-CP 23

I10C-5.0,6 17 P16C-4,2 44 T1-1.2,9 22 TKM-T8C-SD-CP 24


DMS-28752
I10C-5.0,8 17 P16C-4,3 44 T2-1.2,15 22 TMD-1.9 21
Rev-A Date-0921
Superior Implant Technology
TEL +972-8-8531388 | FAX +972-8-8522562 | [Link]

You might also like