0% found this document useful (0 votes)
369 views2 pages

Plamixx 200

Uploaded by

AFSAL
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
369 views2 pages

Plamixx 200

Uploaded by

AFSAL
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
oct 2020 plamixX Technical Data Sheet Description ‘Composition PLAMIXX 200 is o dry mix plaster for internal and external wall. It Ordinary Portland cement, hydrated lime, processed mineral on be applied by suitable plastering machine or by hand. tt is o ‘aggregates and special additives. facry produced dey mix marty, which reques onl adton of wotr jst before use Advantages 1 Frtry med consistent quay product 1 facet bonding and other echnical propetis = bcelet woiaiity 1 Reduces wastage an labour ost 1 Plstaing machine wih slo system Increases out put /coeage Technical data Physical state Premixed granular mortar Binder Ornary Portand cement Colour Grey Size ofthe aggregate 0-14 mm Densiy Dry-1.854g/L, _Wet=1.80Kg/L Walter requirement 140% Approximate yl coverage 30. ton, 42m: Iton @15 mm bckness Working time Approx, 60 minutes. Curing T2hrs wth plable water (3-4 mes a day) Compressive strength >AON mm at 28 ays Flexural svengih > AON mm at 28 days Packing Sib & 5g paperbag Storage & Shel fe ‘?2monts fom he date of manufacturing when stored under dry conditions Applicable standards ‘BS 5262, 5492, 4551, DIN 18550 / 1, 18550 2, ASTM C 926, C897, C 348, 349, C 108/CM01 ‘= The above technicel data are based on controlled laboratory conditions. However, there may be some variation in yield and coverage depending on the ambient weather and ste conditions. Method of application Surface preparation Remove ll the dus, lose patie, cil and grease fom the sufce to be plstred /rendered, Spay suifent amount of eon potable wate to neutalze the sucion ofthe background. low the fee water to completely evaporate before the oplcaion of cement tend Fang of a atochments such spin, elec fitngs, comer beods etc should be cried out befor the rendering is begun For rendering the normal concrete surfoce PLAMDX 100 must be applies keycoo to achive mechanical key on concte surface prior to rendering. On smooth concete, whch is modified with inico sic, cing compound ond any ether typeof organic o inorganic edits PAMBO. 140 must be apa os o kayo, Curing ofthe keycoat wth potable water must be done 3-4 ine @ day for ast 2 dys I the event of dso bckrounds fic sel wie mash across the pint to event the fmatin of cack due to diferent movement of the backgrounds, For stight vertical joins of masonry bckgound 0 "V" groove cat shoud be made in the tendxng when isin wet condition Mixing When oppled with plasting machine the woter is manually adjusted with the flow meter once inthe begining But inthe case af aval eplation, mix one bog of $0 kg mata with 7 L of clon potable water. The mixing shouldbe done with sutole elecicl stv. Maal, which has begun to hacen shuld tbe used Application PIAADX 200 can be oped too thickness of 15-20 mm in one ‘oat on inal wal of once block wit pay machine, For extra ending o spotter dash coo of the same mate Sheu be ppd in 8 - 10 mm thickness withthe help of spay machine. After ot lost wo days of water cng, final coat of render should be opplied on spotter dsh to acieve o taal then of 20mm, Aoatied render must be fished wth wooden flat or plasic owl Use of steel rowel should be vee forthe final irish, Where the thickness is exacted to exceed 20 mm it should be aplid in mule coos with ceeding ticks. In mukile coot application the revious coot of plaster should be card for at lost two dys nd the surface must be scotched in nde to receive th futher aos of later fimly on it Note: On al kindof extemal surfaces the ending must be trted 15 am above the ground level in oder to prevent the vgwad mignon of wate/ sas du othe capillary aon of nde Curing The set lostr/tender shoul be kept mos by curing for minimum Lh with agente sproy of potable water. Precautions Agplain of PAMDO 200 maybe affected by the combined acin of wid un anda, hence all posible protetne moosues, should be adopted during aplication. PANDO shuld nat beheld responsible fr any cam oring out of ronpetfomance of the product due to wrong opplication or usage of product for natecammended purpose, Please contact PLAMDA technical fam for moe det on oppain of PLNMB 200 fr purpose eter thon mentioned oboe Health & Safety The product concins Poond cement, which ofter mixing with water becomes stongly dane ond may couse skin ination if exposed to such contin fra long tne. Avid ination of ust and incase af contact wih eyes and skin, wash wit pleny of clean water and toke medical help if required. Wark in wal venileted condition ond use protective ks suchas mos, gloves and spats. Kap the matralout ofthe reach of cin Note The information conoined in this Techical dota sheet i te, accurate ond represents our best knowledge and experiance, Nevertheless, the coverage of he product ison approximate figure, which depends on vus fcr such as thickness of matt, vwastoge, ombint weather conto, defects of the background andthe kil of he apliatar. Uses must check the coverage ofthe martracording to ther site conditions, PLAMIK wil not entetin any cai elated to such mats. PLAMIXX FACTORY W.L.L P.O.BOX : 82925, DOHA, QATAR, PH: 00974 44641889, FAX : 00974 44641913

You might also like