GENERAL KEY PLAN: N


4. ANCHOR BOLTS ARE TO CONFORM TO:
a. ASTM F1554 GRADE 105 HAVING A MINIMUM YIELD STRESS OF 724 N/mm2 WITH ASSOCIATED TWO NUTS AND WASHER, USED WHERE SPECIFIED ONLY. GALVANIZED A
L
QIB
A. GENERAL NOTES b.
ANCHORS ARE TO BE USED FOR EXPOSED APPLICATION.
HIGH-STRENGTH A490 ANCHOR ROD CONFORM TO ASTM F3125/F3125M, GRADE A490M. OR EN ISO 898-1 (BSEN 14399 WHERE REQUIRED) PROPERTY CLASS 10.9 G. COATING SYSTEMS
(GALVANIZED WHERE REQUIRED) USED WHERE SPECIFIED ONLY.
1. THE BUILDINGS STRUCTURES FOR THE SKI VILLAGE TROJENA PROJECT SHALL BE DESIGNED FOR A MINIMUM DESIGN LIFE OF 50 YEARS
HIGH-PERFORMANCE COATING
5. HIGH-STRENGTH BOLTS, NUTS, AND WASHERS: ASTM F3125M, GRADE A490M, TYPE 1, (OR TYPE 3 WHERE REQUIRED), ASTM A563M MATCHING HEAVY-HEX CARBON-STEEL NUTS (APPLICABLE WHERE FIRE PROTECTION IS NOT REQUIRED)
2. THE NOTES SHALL BE READ IN CONJUNCTION WITH THE SPECIFICATIONS. (TYPE 3 WHERE REQUIRED) AND ASTM F436M MATCHING WASHERS (TYPE 3 WHERE REQUIRED). COATING IN ACCORDANCE WITH ASTM F1136 OR ASTM F2833, AS APPLICABLE; OR
EN ISO 898-1 (BSEN 14399) PROPERTY CLASS 10.9 WITH MATCHING NUTS AND WASHERS. FOR FULL SPECIFICATION AND REQUIREMENTS OF COATING SYSTEM, REFER TO PROJECT SPECS (SECTION 099611: HIGH-PERFORMANCE COATINGS)
3. DO NOT SCALE FROM DRAWINGS, ALL DIMENSIONS SHALL BE READ OR COMPUTED.
6. HEADED STUDS TYPE SHEAR CONNECTORS ARE TO CONFORM TO AWS D1.1, TYPE B, HAVING A MINIMUM YIELD STRESS OF 350 N/mm2 [51000 PSI] AT 0.2% AND MINIMUM TENSILE 1. COATING SYSTEM SHALL COMPLY WITH ISO 12944 ALL PARTS GENERALLY AND ISO 12944-5 SPECIFICALLY FOR CORROSIVITY CATEGORY C4, VERY HIGH DURABILITY FOR ALL
4. UNLESS NOTED OTHERWISE ON THE DRAWINGS, DIMENSIONS ARE GIVEN IN MILLIMETRES AND LEVELS IN METERS. STRENGTH OF 450N/mm2 [65000 psi], MADE FROM STEEL TO ASTM A108, WITH MECHANICAL PROPERTIES TO ASTM A370, AND APPLIED IN ACCORDANCE WITH THE RECOMMENDED ENCLOSED STRUCTURE STEEL WITHIN THE WEATHERTIGHT BUILDING ENVELOPE AND CORROSIVITY CATEGORY C5, VERY HIGH DURABILITY FOR ALL EXTERNAL STRUCTURE
PRACTICES FOR STUD WELDING. STEEL OUTSIDE THE WEATHERTIGHT BUILDING ENVELOPE.
5. ALL STEEL DRAWINGS SHALL BE READ IN CONJUNCTION WITH ALL RELATED CONTRACT DRAWINGS.
E
7. WELDING MATERIALS: CONFORM TO AWS CODE AND AWS FILLER METAL SPECIFICATIONS. SELECT MATERIALS WHICH ARE SUITABLE FOR USE WITH TYPES OF STEEL/STAINLESS 2. WARRANTY: 20 YEARS TO FIRST MAJOR MAINTENANCE FROM DATE OF SUBSTANTIAL COMPLETION.
6. ALL LEVELS AND DIMENSIONS ARE TO BE VERIFIED BY SITE MEASUREMENTS PRIOR TO FABRICATION OF STEEL. STEEL TO BE JOINED.
• METAL-ARC WELDING ELECTRODES: E70XX OR E80XX SERIES OF THE SPECIFICATION FOR MILD STEEL COVERED ARC-WELDING ELECTRODES, AWS A5.1. OR THE 3. REGULAR MAINTENCE TO OCCUR ACCORDING TO SPECIFICATIONS AND ACCORDING TO SUPPLIER TECHNICAL DATA
7. ALL ANCHOR BOLTS INDICATED LENGTHS ARE THE DESIGN EMBEDDED LENGTH MEASURED FROM TOP OF WASHER PLATE TO TOP OF CONCRETE SURFACE, CONTRACTOR TO SPECIFICATION FOR LOW-ALLOY STEEL COVERED ARC-WELDING ELECTRODES, AWS A5.5, IN ADDITION TO OTHER RELEVANT SECTIONS OF AWS SPECIFICATIONS.
ASSESS PROTRUDED LENGTH TO FIT THE TIED BASE PLATES, GROUT, WASHERS & NUTS. • E80XX SERIES SHOULD BE USED FOR THE WELDING OF HIGH GRADE STEEL (GRADE 65 OR S460). 4. SYSTEM COATS:
• BARE ELECTRODES AND GRANULAR FLUX USED IN THE SUBMERGED-ARC PROCESS ARE TO CONFORM TO F7 X-EXXX AWS FLUX CLASSIFICATIONS OF THE A. CORROSION-RESISTANT PRIMING COAT: EPOXY ZINC RICH PRIMER AT DRY FILM THICKNESS OF 80 MICRONS.
8. ALL CONNECTION DETAILS NOT SHOWN IN DESIGN DRAWINGS SHALL BE DESIGNED AND DETAILED BY THE STEEL FABRICATOR BASED ON STRAINING ACTIONS PROVIDED BY THE SPECIFICATION FOR BASE MILD STEEL ELECTRODES AND FLUXES FOR SUBMERGED ARC WELDING, AWS A5.17, OR A5.23 OR THE OF AISC "SPECIFICATION FOR THE B. INTERMEDIATE COAT: EPOXY BASED INTERMEDIATE COATING, TWO COMPONENTS, HIGH BUILD NOT LESS THAN 80 % SOLIDS CONTENT: (C5 LOCATIONS: 200 MICRONS DRY
ENGINEER. RELEVANT DESIGN CALCULATIONS ARE TO BE SUBMITTED FOR ENGINEER'S APPROVAL. DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS". FILM THICKNESS) AND (C4 LOCATIONS: 140 MICRONS DRY FILM THICKNESS).
C. TOPCOAT: ACRYLIC/ALIPHATIC POLYURETHANE FINISH COATING.
9. ANY SECTION OR MATERIAL SUBSTITUTION DUE TO MARKET AVAILABILITY SHALL BE SUBMITTED TO ENGINEER FOR APPROVAL NOTING THAT THIS SUBSTITUTION SHALL NOT 8. FABRICATED SECTIONS SHALL HAVE A MINIMUM CHARPY V-NOTCH TOUGHNESS OF 27 JOULES @ -21 °C DETERMINED AS SPECIFIED IN AISC 360 : 2010.
RESULT IN ADDITIONAL COST OR DELAY.
5. TOUCH-UP PAINT SHOULD BE PROVIDED AFTER STEEL INSTALLATION TO REPAIR ANY PANTING DAMAGE OCCURRED DURING THE ERECTION.
9. CARRY OUT ULTRASONIC TESTING FOR LAMINATION ON ALL HEAD PLATES FOR MOMENT CONNECTIONS (15 MM THICK OR ABOVE) AND FOR ALL PLATES (25 MM THICK OR ABOVE)
10. ANY PROPOSED SUBSTITUTION TO A SELECTED CONNECTION SHOWN ON DESIGN DRAWINGS SHALL BE SUBSTANTIATED WITH DESIGN CALCULATIONS AND SUBMITTED FOR IN ACCORDANCE WITH ASTM E164, ASTM A435, BS EN10160, BS EN ISO 17640, BS EN ISO 2400. SPRAYED FIRE RESISTIVE SYSTEM (CEMENTITIOUS)
ENGINEER'S APPROVAL.
10. (Z-QUALITY) FOR PLATES SUBJECT TO TENSILE STRESSES THROUGH THICKNESS SHALL BE IN ACCORDANCE WITH ASTM A770/A770M OR BS EN 10164 WITH THE BELOW MINIMUM FOR FULL SPECIFICATION AND REQUIREMENTS, REFER TO PROJECT SPECS SECTION 078100 -APPLIED FIREPROOFING-. IN PARTICULAR:
11. THE STRUCTURAL DRAWINGS SHOW ONLY THE PRIMARY STRUCTURAL STEEL ELEMENTS. ALL ADDITIONAL METAL SUPPORTING SYSTEM FOR NON-STRUCTURAL WORKS (E.G. VALUES:
FACADE, CEILING, DUCTING, ETC,) SHALL BE DESIGNED/DETAILED BY CONTRACTOR IN ACCORDANCE TO THE DRAWINGS OF OTHER TRADES AND PROJECT SPECIFICATIONS. 1. EPOXY-ZINC-RICH PRIMER IN NUMBER AND THICKNESS OF COATS TO SATISFY THE WARRANTY PERIOD TO FIRST MAINTENANCE AS SPECIFIED. PRIMER COAT SHALL COMPLY WITH ISO12944 NOTES:
. ALL PARTS GENERALLY AND ISO 12944-5 SPECIFICALLY FOR CORROSIVITY CATEGORY C4, VERY HIGH DURABILITY FOR ALL ENCLOSED INTERNAL STRUCTURE STEEL WITHIN THE
12. STRUCTURAL DRAWINGS REFLECT THE ARCHITECTURAL COORDINATION LEVEL OCCURRED UP TO SUBMISSION DATE. PLATE THICKNESS MINIMUM Z VALUE WEATHERTIGHT BUILDING ENVELOPE AND CORROSIVITY CATEGORY C5, VERY HIGH DURABILITY FOR ALL EXTERNAL STRUCTURE STEEL OUTSIDE THE WEATHERTIGHT BUILDING ENVELOPE - FOR GENERAL NOTES REFER TO DRAWINGS 07-001100-4800000606-DAH-STR-DRG-010001 / 010002 / 010003 / 010011;

13. ANY MODIFICATION TO STAIR AND LIFT SHAFTS DIMENSIONS SHALL BE IMPLEMENTED AS A DRAWING REVISION 2. ADHESIVE FOR BONDING FIRE-RESISTIVE MATERIAL CERTIFIED AS COMPATIBLE WITH THE APPLIED PRIMER.
TH. 20 Z = 15
14. ANY MODIFICATION TO SLAB EDGES DIMENSIONS SHALL BE IMPLEMENTED AS A DRAWING REVISION TH. 40 Z = 25 3. SFRM IN THICKNESS REQUIRED TO OBTAIN THE INDICATED FIRE RESISTANCE RATING FOR EACH STRUCTURAL STEEL SECTION BASED ON THE RATIO HP/A OF THE SECTION AND THE
LOADING TABLES (COATING THICKNESS TABLES) CERTIFIED BY THE THIRD-PARTY TESTING AGENCY WHICH ACCREDITED THE FIRE RATING OF THE SFRM PRODUCT.
15. ANY ADDITIONAL STRUCTURAL MEMBER REQUIRED TO SUPPORT THE KNUCKLES CLADDING SHALL BE IMPLEMENTED AS A DRAWING REVISION TH. 40 Z = 35
4. TWO SEALER COATS WHERE THE SFRM IS USED WITHIN A CEILING AIR PLENUM.
16. ANY ADDITIONAL STRUCTURAL MEMBER REQUIRED TO SUPPORT LOCAL OPENINGS AND SHAFTS IN THE FLOORS SHALL BE IMPLEMENTED AS A DRAWING REVISION
11. IT IS CONTRACTOR SCOPE TO IDENTIFY TENSILE THROUGH THICKNESS PLATES. IN CASE SUCH ANALYSIS IS NOT COMPLETED AT THE TIME THE STEEL IS PURCHASED,ALL PLATES 5. WARRANTY PERIOD FOR SPRAYED FIRE-RESISTIVE MATERIALS CORROSION PROTECTION PERFORMANCE IS 20 YEARS TO FIRST MAJOR MAINTENANCE FROM DATE OF SUBSTANTIAL
17. CONTRACTOR SHALL ENGINEER ALL SECONDARY STEEL ELEMENTS REQUIRED BY THE CONTRACT DOCUMENTS TO WITHSTAND DESIGN LOADINGS INDICATED. SECONDARY SHALL COMPLY THE ABOVE REQUIREMENT. COMPLETION.
STEEL ELEMENTS INCLUDE BUT NOT LIMITED TO: CATWALKS, HANDRAILS, LADDERS, MOVABLE PARTITIONS, ELECTRO-MECHANICAL SUPPORTS, RAIN GUTTERS SUPPORTS, DOOR
FRAMES, ROOF OPENINGS, AND ANY SUBSTRUCTURE FOR CLADDING OR FAÇADE ELEMENTS.

D 18. CONTRACTOR SHALL ENGINEER THE EXTENT OF STRUCTURAL STEEL SHOWN IN ARCHITECTURAL, LANDSCAPE, AND TRANSPORTATION DRAWINGS REQUIRED BY THE CONTRACT
F. FABRICATION / ERECTION / COORDINATION INTUMESCENT PAINT SYSTEM

DOCUMENTS TO BE FULLY DESIGNED ACCORDING TO THE CODES, AND STANDARDS INDICATED IN THIS SECTION. FOR FULL SPECIFICATION AND REQUIREMENTS, REFER TO PROJECT SPECS SECTION 078123 - INTUMESCENT FIRE PROTECTION -. IN PARTICULAR:

19. CONTRACTOR SHALL ENGINEER STRUCTURAL STEEL CONNECTIONS REQUIRED BY THE CONTRACT DOCUMENTS TO BE SELECTED OR COMPLETED TO WITHSTAND DESIGN 1. FABRICATION, ERECTION, AND CONSTRUCTION SHALL COMPLY WITH AISC 303. AS A MINIMUM, STRUCTURAL ELEMENTS SHALL COMPLY WITH EXECUTION CLASS EXC3 ACCORDING 1. COATING SYSTEM SHALL COMPLY WITH ISO 12944 ALL PARTS GENERALLY AND ISO 12944-5 SPECIFICALLY FOR CORROSIVITY CATEGORY C4, VERY HIGH DURABILITY FOR ALL ENCLOSED
LOADINGS INDICATED. THE ENGINEERING TASK INCLUDES THE DESIGN OF ANY CONNECTION DETAILS NOT SHOWN IN DESIGN DRAWINGS TO WITHSTAND STRAINING ACTIONS TO EN1090-2-2018 STRUCTURE STEEL WITHIN THE WEATHERTIGHT BUILDING ENVELOPE AND CORROSIVITY CATEGORY C5, VERY HIGH DURABILITY FOR ALL EXTERNAL STRUCTURE STEEL OUTSIDE THE
SUPPLIED BY THE ENGINEER. DESIGN TASK INCLUDES BUT NOT LIMITED TO ANY STIFFENING OR STRENGTHENING REQUIRED LOCALLY TO MEMBERS DUE TO CONNECTION WEATHERTIGHT BUILDING ENVELOPE.
CONFIGURATION OR DESIGN FORCES IN THE CONNECTION ZONE (FLANGE THICKENING, WEB THICKENING, DOUBLER PLATES, STIFFENERS, MEMBER LOCAL THICKENING,...ETC.). 2. ALL DIMENSIONS GIVEN ON CONTRACT DRAWINGS ARE TO BE CHECKED BY THE STEEL FABRICATOR PRIOR TO FABRICATION.
2. CORROSION-PROTECTION PRIME COAT: COMPATIBLE WITH INTUMESCENT PAINT AND APPROVED BY FIREPROOFING MANUFACTURER AND COMPLYING WITH REQUIRED FIRE
20. MAXIMUM OFFSET OF 3D PRINTED CONCRETE IS 500mm FROM PRIMARY STEEL STRUCTURES 3. THE CONTRACTOR SHALL PROVIDE ALL HOLES IN THE STEELWORK REQUIRED BY OTHER TRADES, SUBJECT TO THE APPROVAL OF ENGINEER. RESISTANCE DESIGN WITH NUMBER AND THICKNESS OF COATS SATISFYING THE WARRANTY PERIOD TO FIRST MAINTENANCE AS SPECIFIED.

4. THE STRUCTURE IS DESIGNED TO FUNCTION AS ONE UNIT UPON COMPLETION. THE CONTRACTOR SHALL PROVIDE TEMPORARY BRACING AND SUPPORTS REQUIRED DURING
ERECTION FOR THE PROPER ALIGNMENT AND ALSO AS NECESSARY TO GIVE AND MAINTAIN THE PROPER STABILITY OF ALL STRUCTURE. 3. INTUMESCENT PAINT LAYER: THIN-FILM INTUMESCENT FIRE RESISTIVE COATING FOR LOAD-BEARING STRUCTURAL STEEL AND COMPLYING WITH INDICATED FIRE-RESISTANCE DESIGN
THAT SHALL BE COMPATIBLE WITH PRIMER SPECIFIED AND SHALL ACCEPT WIDE RANGE OF DECORATIVE FINISH COATINGS.
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE STABILITY OF THE STRUCTURE DURING ERECTION, I.E. ITS TEMPORARY CONDITION, INCLUDING THE EFFECTS FROM TOWER
B. LIST OF ABBREVIATIONS (U.N.O.) CRANES AND HOISTS WHERE THESE ARE SUPPORTED AND/OR RESTRAINED BY THE STRUCTURE. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY CALCULATIONS FOR THE 4. TOPCOAT: ACRYLIC/ALIPHATIC POLYURETHANE FINISH COATING SUITABLE FOR APPLICATION OVER APPLIED FIREPROOFING AND RECOMMENDED BY INTUMESCENT PAINT
TEMPORARY STRUCTURE WITH DETAILED MEMBER CHECKS WHERE REQUIRED. ALL ADDITIONAL STEEL REQUIRED FOR THE TEMPORARY STABILITY OF THE STRUCTURE SHALL BE MANUFACTURER.
1- "ADD." REFERS TO "ADDITIONAL" 13- "GA." REFERS TO "GAUGE" 25- "R" REFERS TO "RADIUS" 37- "VL." REFERS TO "VERTICAL" DEEMED TO BE INCLUDED BY THE CONTRACTOR AND REMOVED FROM THE SITE UPON COMPLETION OF THE PERMANENT STRUCTURE.
2- "AR" OR "ARCH." REFERS TO "ARCHITECTURAL" 14- "H" REFERS TO "HINGED CONNECTION" 26- "R.C." REFERS TO "REINFORCED CONCRETE" 38- "∅" REFERS TO "DIAMETER" 5. WARRANTY PERIOD FOR CORROSION RESISTANCE FOR THE WHOLE SYSTEM (INCLUDING PRIMER, INTUMESCENT PAINT, AND TOP FINISH COAT) IS 20 YEARS TO FIRST MAJOR
3- "CHQ." REFERS TO "CHEQUERED" 15- "HZ." REFERS TO "HORIZONTAL" 27- "S" REFERS TO "SLOTTED CONNECTION" 39- "<" REFERS TO "ANGLE IN DEGREES" 6. ERECTION METHOD STATEMENT IS UNDER THE SCOPE OF CONTRACTOR. RESIDUAL STRESSES DUE TO ERECTION METHODOLOGY (ALSO REFERRED TO AS LOCKED-IN-FORCES) MAINTENANCE FROM DATE OF SUBSTANTIAL COMPLETION.
4- "C.L" REFERS TO "CENTERLINE" 16- "L" REFERS TO "ANGLE PROFILE" 28- "SC." REFERS TO "SCALE" 40- "RHS" REFERS TO "RECTANGULAR HOLLOW SECTION" SHALL BE LIMITED TO 5% OF MEMBER CAPACITY. CONTRACTOR TO INTRODUCE ADEQUATE NUMBER OF TEMPORARY SUPPORTS TO FULLFILL THIS REQUIREMENT.
5- "CONC." REFERS TO "CONCRETE" 17- "M" REFERS TO "RIGID MOMENT CONNECTION" 29- "SECT." REFERS TO "SECTION" 41- "SHS" REFERS TO "SQUARE HOLLOW SECTION"
6- "DOCS." REFERS TO "DOCUMENTS" 18- "MAX." REFERS TO "MAXIMUM" 30- "SPECS." REFERS TO "SPECIFICATIONS" 42- "CHS" REFERS TO "CIRCULAR HOLLOW SECTION" 7. ERECTION METHOD STATEMENT ILLUSTRATING SEQUENCE OF ERECTION AND THE ADEQUATE PROTECTION OF WORKS DURING CONSTRUCTION SHALL BE SUBMITTED FOR
7- "DWGS." REFERS TO "DRAWINGS" 19- "ME" OR "MECH." REFERS TO "MECHANICAL" 31- "STIFF." REFERS TO "STIFFENER" 43- "CJP" OR "CP" REFERS TO COMPLETE JOINT PENETRATION. DESIGNER'S APPROVAL SUPPORTED BY CLEAR CALCULATIONS AND ANALYSIS MODELS "AS NEEDED" PRIOR TO COMMENCEMENT OF ERECTION WORKS. FABRICATION AND
8- "EL" OR "ELEC." REFERS TO "ELECTRICAL" 20- "MIN." REFERS TO "MINIMUM" 32- "T.O.C." REFERS TO "TOP OF CONCRETE" 44- "FP" REFER TO FULL PENETRATION. INSTALLATION LOADS SUCH AS LIFTING FORCES AND LOAD-OUT FORCES ARE TO BE EVALUATED BY THE CONTRACTOR AND SHOWN CLEARLY IN THE ERECTION METHOD
STATEMENT WITH ALL THE REQUIRED PRECAUTIONS TO ENSURE THE STRUCTURE, MEMBERS, AND CONNECTIONS SAFETY. EXTERNAL SKISLOPE C5
9- "EQ." REFERS TO "EQUAL" 21- "MISC." REFERS TO "MISCELLANEOUS" 33- "T.O.S." REFERS TO "TOP OF STEEL" 45- "SEC. BEAM" REFER TO SECONDARY BEAM.
10- "EXP." REFERS TO "EXPANSION" 22- "N.T.S." REFERS TO "NOT TO SCALE" 34- "TYP." REFERS TO "TYPICAL" 46- "MST" REFER TO MULTI STOREY TRUSS.
11- "FL." REFERS TO "FLANGE" 23- "P.P." REFERS TO "PARTIAL PENETRATION" 35- "U.N.O." REFERS TO "UNLESS NOTED OTHERWISE" 47- HCS HOLLOW CORE SLAB 8. AVOID SUBJECTING MEMBERS TO HIGH-STRAIN LEVELS DURING THE FABRICATION AND AVERT CHANGING MATERIAL PROPERTIES (YIELD STRESS, ULTIMATE STRESS, DUCTILITY,
12- "F.F.L." REFERS TO "FINISH FLOOR LEVEL" 24- "PL." REFERS TO "PLATE" 36- "VAR." REFERS TO "VARIABLE" TOUGHNESS, HARDNESS…).

1. THE SHOWN SYMBOLS ON DRAWINGS FOR COMPLETE AND PARTIAL JOINT PENETRATION WELDING DETAILS ARE INDICATIVE. THE CONTRACTOR IS RESPONSIBLE FOR
C. LOADS UTILIZING THE PROPER WELDING PROCEDURE, SEQUENCE, THROUGH-THICKNESS TENSION PROPERTIES (Z-QUALITY) MATERIAL TO RESPECT AND FULFIL THE DESIGN
INTENT.
C DESIGN LOADS ARE IN ACCORDANCE WITH THE FOLLOWING STANDARDS: 2. WHEN MEMBERS ARE SUBJECTED TO HIGH-STRAIN LEVELS, THE APPROPRIATE PREHEAT AND COOLING TREATMENT AND INTERPASS TEMPERATURE MUST BE SUFFICIENT
TO PREVENT CRACKING, AVOID OVERHEATING, ENSURE SLOW COOLING RATES, GUARANTEE WELDED JOINT DUCTILITY…ETC.
1. FOR DETAILED LOADING CRITERIA, REFER TO STRUCTURAL REPORT 07-001100-4800000606-DAH-STR-RPT-000001_B. 3. THE METHOD STATEMENT FOR THE USED PROCEDURES AND TECHNIQUES COMPLYING WITH THE RELEVANT STANDARD REGULATIONS (AWS, AISC, ASTM, AASHTO…ETC.)
MUST BE SUBMITTED FOR ENGINEER'S APPROVAL PRIOR TO FABRICATION.
2. LIVE LOADS ARE IN ACCORDANCE WITH SBC 301-18, "SAUDI LOADING CODE", AS MINIMUM.
9. ALL TEMPORARY ATTACHMENTS WELDED TO STEEL SHALL BE SHOWN ON THE SHOP DRAWINGS AND ULTIMATELY BE REMOVED. AN ULTRASONIC EXAMINATION FOR LAMINATION
3. WIND LOADS ARE ACCORDING TO SBC 301-18, THE 3-SEC GUST ULTIMATE WIND SPEED IS 50M/S FOR STRUCTURES, WITH RISK CATEGORY III. EXPOSURE CATEGORY C. 5m SHALL BE PERFORMED WHERE THE ATTACHMENT CAUSES TENSILE STRESSES IN THE THICKNESS DIRECTION. THE ATTACHMENT SHALL BE REMOVED BY CUTTING AT LEAST 3 MM EXTERNAL CANTILEVERS C5
OF ITS LENGTH MEASURED FROM THE PERMANENT STRUCTURE SURFACE. THE LAST 3 MM SHALL BE REMOVED BY GRINDING. AFTER THE REMOVAL OF THE ATTACHMENT, LIQUID
4. SEISMIC LOADS ARE IN ACCORDANCE WITH SBC 301-18, USING THE AVAILABLE SITE SPECIFIC STUDY WITH -CONSIDERING THE CODE LIMITS - WITH THE FOLLOWING PARAMETERS PENETRATION TEST SHALL BE CARRIED OUT TO ENSURE THAT THE SURFACE IS FREE OF CRACKS.
CONSIDERING STRUCTURAL RISK CATEGORY III : EXTERNAL CANTILEVERS C5
SHORT PERIOD DESIGN RESPONSE (SDS) = 0.385 10. FABRICATION, ERECTION AND QUALITY CONTROL (INCLUDING TOLERANCES) OF STEEL CONSTRUCTION TO BE AS INDICATED BY ASTM A6, AWS D1.1, AND AISC MANUAL OF STEEL REFERENCE NUMBER DESCRIPTION
5m

5m

1 SECOND DESIGN RESPONSE (SD1) = 0.096 CONSTRUCTION. 07-001100-4800000606-DAH-STR-MDL-110010 SHEETS - GENERAL ECI PACKAGE
IMPORTANCE FACTOR = 1.25
11. CONTRACTOR/STEEL DETAILER IS RESPONSIBLE FOR ALL MEMBERS SHOWN ON THESE DRAWINGS INCLUDING, BUT NOT LIMITED TO, OUTRIGGERS, STRUTS, ANGLES, PLATES,
5. TEMPERATURE VARIATION ± 30° C. 5m 5m FASTENERS, ETC.
5m 5m

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF NEOM. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT FROM NEOM.
6. MAXIMUM SNOW ACCUMULATION ALLOWED ON SKI SLOPE IS EQUAL TO AN EQUIVALENT DISTRIBUTED LOAD OF 7.2 KN/M2 OVER ONE THIRD OF THE SLOPE OR A PYRAMID OF 12. CONTRACTOR/STEEL DETAILER IS RESPONSIBLE FOR COORDINATING ALL MEMBERS AND STRUCTURAL GEOMETRY IN ALL DIRECTIONS (X, Y, Z) AND REVIEWING THE SAME
DIMENSIONS 5M X 5M X 5M EACH 5M ON THE SIDE OF THE SLOPE OR AN EQUIVALENT LOAD. AGAINST THE INFORMATION SHOWN ON THE ARCHITECTURAL DRAWINGS PRIOR TO FABRICATION. STEEL FRAMING SHALL BE COORDINATED THOROUGHLY WITH ARCHITECTURAL
STAGE:
WALL SECTIONS.
7. THE FOLLOWING CONCENTRATED LOADS CAN BE RESISTED BY THE RC SLAB ON METAL DECK OF THE SKI SLOPE: STAGE 3D TENDERING & IFC
- 40 KN ON AN AREA OF 0.3X0.3M DIRECTLY ON THE RC SLAB 13. ALL SECONDARY MEMBERS NOT SHOWN ON STRUCTURAL DRAWINGS ARE PART OF THE SKIN, FINISHES, MEP SUPPORTS, ETC., AND SHALL BE DESIGNED/PROVIDED BY THEIR
- 50 KN ON AN AREA OF 0.3X0.3M DIRECTLY ON THE GRAVEL LAYER RESPECTIVE SUPPLIERS AND SHALL BE SUBMITTED FOR ENGINEERS'S REVIEW AND APPROVAL.
- 150 KN ON AN AREA OF 4.5X6.5M (GROOMER FOOTPRINT) DIRECTLY ON THE TOP OF A MINIMUM OF 0.4M SNOW LAYER (MAXIMUM OF 5 KN/M2) INTERNAL BUILDING C4 02 ISSUED FOR CONSTRUCTION FV 24/12/2023
14. CONTRACTOR IS TO SUBMIT WORKSHOP DETAIL DRAWINGS FOR ENGINEER'S APPROVAL PRIOR TO EXECUTION.
01 STAGE 3D - TENDERING & IFC FV 18/09/2023
D. DESIGN 15. CONTRACTOR SHALL REVIEW AND COORDINATE SHOP DRAWINGS WITH ALL STEEL FRAMING ELEMENTS SHOWN HEREIN AND AS DETAILED ON OTHER TRADES DRAWINGS.
REV
PURPOSE OF ISSUE:
DESCRIPTION APP DATE

COORDINATION WITH EXISTING STRUCTURES AND SITE CONDITIONS IS ALSO REQUIRED. ANY CHANGES ARE TO BE REPORTED FOR ENGINEER PRIOR TO FABRICATION.
THE DESIGN IS IN ACCORDANCE WITH THE FOLLOWING STANDARDS: FIRST 0.5 METER FROM BASE PLATE C5
16. CUTS/OPENINGS OTHER THAN THOSE SHOWN ON DRAWINGS NEED TO OBTAIN THE ENGINEER'S APPROVAL.
1. SBC 306-18, SAUDI STEEL STRUCTURES CODE CLIENT: PROJECT MANAGEMENT CONSULTANT:

17. ALL BOLTED CONNECTIONS SHALL SUBJECT TO COORDINATION AND APPROVAL BY ARCHITECTURAL.
2. AISC 360-16, SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS
18. ALL HOLES FOR STEEL BOLTS ARE WITH STANDARD DIAMETER SIZE AS PER AISC 15TH EDITION, UNLESS NOTED OTHERWISE.
H. STRUCTURAL BEARING DEVICES
B 3. AISC 303, CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES.
19. ALL BOLTED MOMENT CONNECTIONS AND SPLICES TO BE SLIP RESISTANCE U.N.O. FOR SPECIFICATIONS AND REQUIREMENTS OF BEARINGS, REFER TO PROJECT SPECS (SECTION SECTION 348323 - BRIDGE BEARINGS). IN PARTICULAR:
4. AISC MANUAL OF STEEL CONSTRUCTION, 15TH EDITION.
20. ALL CONNECTIONS (OTHER THAN MOMENT CONNECTIONS) SHALL BE SLIP CRITICAL FOR DESIGN LOAD EQUALS TO ULS / 1.4, UNO. (ULS IS THE MOST CRITICAL FACTORED LOAD) 1. COMPLY WITH THE PROVISIONS OF FOLLOWING CODES: BS EN 1337-2, BS EN 1337-3, BS EN 1337-4, BS EN 1337-5, BS EN 1337-6, BS EN 1337-7 AND BS EN 1337-8.
5. AISC DESIGN GUIDE SERIES NUMBERS 1- 29.
21. ALL SLIP CRITICAL CONNECTIONS, HEAD PLATE CONNECTIONS, AND BOLTED SPLICE CONNECTIONS REQUIRE FULL BOLT PRE-TENSIONING AND CLASS "B" FAYING SURFACE (µ=0.5) 2. POT BEARING ACCORDING TO EN 1337-5 OR SPHERICAL BEARINGS ACCORDING TO EN 1337-7
6. AISI, “NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS”, MANUAL EDITION 2017. AS PER THE REQUIREMENTS OF RCSC SPECIFICATIONS FOR STRUCTURAL JOINTS. LEAD DESIGN CONSULTANT: MULTIDISCIPLINARY DESIGN CONSULTANTS:
3. CE MARK REQUIRED
7. ANSI/AWS D1.1/D1.1M, STRUCTURAL WELDING CODE: AMERICAN WELDING SOCIETY - LATEST EDITION. 22. CONTRACTOR SHALL USE DIRECT TENSION INDICATOR (DTI) WASHER FOR ALL PRE-TENSIONED BOLTS AS PER PROJECT SPECIFICATIONS 051200 TO CONTROL AND ENSURE
CORRECT BOLT TIGHTENING. 4. THE BEARINGS ARE DESIGNED TO PERMIT LIMITED ANGULAR ROTATIONS AROUND ANY AXIS. THE ROTATION CAN HAPPEN BY MEANS OF THE DEFORMABILITY OF THE
8. SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH STRENGTH BOLTS, RCSC ELASTOMERIC PAD
C:\Users\[Link]\Desktop\ECI GENERAL PACKAGE\[Link]

23. CONNECTIONS OF HORIZONTAL FLOOR TIES ARE TO BE DESIGNED FOR FACTORED NORMAL FORCE OF 250KN AS MINIMUM.
9. SBC 801-18, “FIRE PROTECTION” 5. FOR SLIDING SURFACES, PTFE MUST BE USED FOR PLAN SLIDING SURFACES AND PTFE OR CM1 FOR SIDE GUIDES ACCORDING TO EN1337-2
24. TIE PLATES ARE TO BE PROVIDED FOR ALL DOUBLE ANGLES WITH MAXIMUM SPACING EQUAL TO ONE THIRD OF THE MEMBER LENGTH.
6. FOR BEARING CAPACITY, MOVEMENT, ANGLE OF ROTATION, ETC, REFER TO LOAD DESIGN TABLES SHOWN ON THE RELEVANT DRAWING
E. MATERIAL 25. ALL WELDS TO BE CJP U.N.O. DESIGN CONSULTANT / CONTRACTOR: NEOM'S REVIEW:
DRAWN: PO 24/12/2023
1. STRUCTURAL STEEL MATERIAL SHALL CONFORM TO THE FOLLOWING STANDARDS: 26. MINIMUM SIZE OF FILLET WELDS IS S=1 OF MINIMUM WELDED THICKNESS OR 6 MM, WHICHEVER IS BIGGER U.N.O. ALL WELDS BETWEEN FLANGES AND WEBS OF BUILT-UP
CHECKED: EM 24/12/2023 CHECKED:
SECTIONS ARE CONTINUOUS FILLET WELDS FROM BOTH SIDES, U.N.O.
TYPICALLY USED USED WHERE SPECIFIED ONLY APPROVED: FV 24/12/2023 APPROVED:

ASTM STANDARD EN STANDARD ASTM STANDARD EN STANDARD 27. PREHEAT AND COOLING TREATMENT: THE PREHEAT AND INTERPASS TEMPERATURE MUST BE SUFFICIENT TO PREVENT CRACKING. FLANGES AT LOCATION OF WEB WELD SHALL
SECTION/PROFILE TYPE BE PREHEATED TO A TOTAL WIDTH OF 200MM. MAINTAIN SPECIFIED TEMPERATURE DURING WELDING. AVOID OVERHEATING. COOLING RATE SHALL BE SLOW TO AVOID CRACKING, SCALE: SHEET SIZE: A0
MAX thick. Fy Fu MAX thick. Fy Fu MAX thick. Fy Fu MAX thick. Fy Fu AND TO ENSURE WELDED JOINT DUCTILITY. THE CONTRACTOR SHALL SUBMIT A METHOD STATEMENT ON PREHEATING/COOLING PROCEDURES AND TECHNIQUES BASED ON AWS DISCIPLINE NAME:
(mm) (MPa) (MPa) (mm) (MPa) (MPa) (mm) (MPa) (MPa) (mm) (MPa) (MPa) D1.1 REGULATIONS FOR THE ENGINEER'S APPROVAL PRIOR TO FABRICATION.
STRUCTURE
ASTM A572/A992 GRADE 50 BS EN 10025 GRADE S355 ASTM A1066 GRADE 65 BS EN 10025 GRADE S460
STRUCTURAL STEEL HOT-ROLLED SECTIONS 28. ALL SITE WELDS ARE TO BE SUBJECT TO 100% NON DESTRUCTIVE TESTING (ULTRASONIC AND/OR X-RAY).
STRUCTURAL STEEL PLATES FOR BUILT-UP-SECTIONS AND
100 mm 345 MPa 450 MPa
40 mm 355 MPa 490 MPa
150 mm 450 MPa 550 MPa
40 mm 460 MPa 540 MPa ECI - GENERAL NOTES
CONNECTIONS 80 mm 335 MPa 470 MPa 80 mm 430 MPa 540 MPa 29. THE THREADING OF THE PRESET ANCHOR BOLTS IS TO BE TESTED TO GUARANTEE THAT NO SLIP OF NUTS OCCURS BEFORE THE FAILURE OF ANCHOR BOLTS MATERIAL.
A618 GRADE III BSEN 10210 GRADE S355 A618 GRADE IV BSEN 10210 GRADE S460 STEEL AND HOLLOW CORE SLAB - 01
STRUCTURAL STEEL PIPES "HOLLOW CIRCULAR SECTIONS" 30. CONTRACTOR/FABRICATOR SHALL INSPECT AND APPROVE THE FINAL ANCHOR BOLTS AND EMBEDDED PLATES LAYOUT PRIOR TO CONCRETE POURING.
40 mm 355 MPa 510 MPa 19 mm 460 MPa 550 MPa 40 mm 460 MPa 560 MPa PROJECT NAME:
65 345 MPa 450 MPa
31. NON-SHRINK GROUT TO HAVE A MINIMUM COMPRESSIVE STRENGTH OF 80 N/MM2 AT 28 DAYS HAVING A WORKING TIME OF 30 MINUTES.
A
80 mm 335 MPa 490 MPa 38 mm 440 MPa 540 MPa 80 mm 430 MPa 550 MPa TROJENA SKI VILLAGE
65 mm 430 MPa 540 MPa
32. ALL STEEL MEMBERS SHALL BE CORROSION PROTECTED IN ACCORDANCE WITH PROJECT SPECIFICATIONS.
ASTM A501 GRADE B BSEN 10210 GRADE S355 -- BSEN 10210 GRADE S460 TROJENA - FUN CLUSTER
STRUCTURAL STEEL SQUARE AND RECTANGULAR TUBES
33. THE STEEL ELEMENTS SHALL BE FIRE RATED PAINTED/SPRAYED ACCORDING TO THE FIRE PROTECTION REQUIREMENTS SHOWN ON THE DRAWINGS AND AS PER ARCHITECTURAL
"HOLLOW SQUARE AND RECTANGULAR SECTIONS 40 mm 355 MPa 510 MPa 40 mm 460 MPa 560 MPa
-- 345 MPa 483 MPa -- -- -- DRAWINGS/DOCUMENTS. NEOM
80 mm 335 MPa 490 MPa 80 mm 430 MPa 550 MPa

NOTE: HOT-FORMED CIRCULAR HOLLOW SECTIONS MAY BE CONVERTED TO EQUIVALENT COLD-FORMED SECTIONS ACCORDING TO MARKET AVAILABILITY, SUBJECT TO CONSULTANT APPROVAL AND TO BE
34. FOR CORROSION AND FIRE PROTECTION "RATING DURATION & MATERIAL" OF STEEL STRUCTURE, REFER TO ARCHITECTURAL DOCUMENTS. AS A MINMUM, REFER TO ITEMS G & K. KINGDOM OF SAUDI ARABIA
MANUFACTURED AND FABRICATED BASED ON AMERICAN OR INTERNATIONALLY RECOGNIZED REFERENCE / STANDARD. REGION ASSET CODE CONTRACT CODE
35. FOR THE ON GROUND STEEL AT LANDSCAPE, THE FIRST 50 cm FROM THE STEEL COLUMN AND BASE PLATE SHALL BE SPECIAL TREATED TO AVOID POSSIBILITY OF CORROSION AT
GRADE. THE SAME IS REQUIRED FOR THE EMBEDDED STEEL UNLESS IT IS EMBEDDED WITH GROUT OR CONCRETE.
2. CHEQUERED PLATES ARE TO CONFORM TO BSEN 10025 GRADE S235, OR ASTM A36 HAVING A MINIMUM YIELD STRESS OF 250 N/MM2 UNLESS NOTED OTHERWISE WITH THE REQUIRED LAYERS OF PROTECTIVE
07 001100 4800000606
05-Mar-24 [Link] PM

COATING (TOP SURFACE SHOULD BE PROTECTED WITH ANTI-ABRASION PAINTS-TO ENSURE THE SPECIFIED LIFE TO FIRST MAINTENANCE), AND PAINTED WITH INTUMESCENT PAINT FIRE PROTECTION (2 HOURS
36. SKIN SUPPLIER SHALL CONSIDER THE STRUCTURE DEFLECTION DUE TO THE DEAD LOAD TO AVOID PONDING ON THE ROOF.
FIRE RATING) AS SPECIFIED IN PROJECT SPECS. DRAWING NUMBER
37. IT IS CONTRACTOR RESPONSIBILITY TO VERIFY ALL SLAB EDGES AND SLAB OPENINGS WITH THE FINAL ARCHITECTURAL MODEL. ORIGINATOR DISCIPLINE DOCUMENT TYPE SEQUENTIAL NUMBER REV NO.
3. COLD ROLLED STEEL Z AND C SECTIONS ARE TO CONFORM TO (BSEN 101747 GRADE S450GD (450 N/MM2), OR ASTM A653M GRADE HSLAS, TYPE A, GRADE 70 (480) AND ASTM A924/A924M, HAVING A MINIMUM YIELD
STRESS 345 N/MM2 AND SHALL BE GALVANIZED IN ACCORDANCE WITH THE ASTM A653M WITH ZINC COATED TO ACHIEVE THE SPECIFIED LIFE TO THE FIRST MAINTENANCE.
DAH STR DRG 010002 02
NEOM-NEN-PRC-009_TMP12_02.00