STN for double and
triple pendulum
configurations
Paola Puppo
10/11/2023
Scenario for payload design in post-O5 Low
All large test masses with a
monolithic intermediate
mass
triple pendulum The use of a
penultimate mass allows the losses
coming from the marionette to be
filtered.
Relevant gain in the low frequency
range
• A full triple pendulum model has
been developed analytically for a
better evaluation of the
suspension thermal noise;
- Sinergy with 3G detectors
cryogenic suspensions for
mechanical point of view Dashed blue line:
Large masses: with a monolithic intermediate mass
2
Suspension thermal of the Triple pendulum
L1=1125mm Maraging (Qmario=50000)
L2=700 mm Silica
L3=700 mm Silica (opt)
m1=185 kg
DoubleP with losses
m2=105 kg
on marionette
m3=105 kg
DoubleP without TripleP with losses on
losses on marionette marionette
Thermals comparison (bouncing
modes and four suspensions)