Finus 70

The document outlines the features and technologies of the Finus 70 Ultrasound Diagnostic System, highlighting its advanced imaging capabilities through the Harmony Imaging Platform, Micro Flow technology, and various applications such as elastography and tissue Doppler imaging. It emphasizes the system's performance improvements, including enhanced resolution and penetration, as well as ergonomic design elements for user convenience. Additionally, it mentions the integration of remote consultation features and premium in-house technologies for optimal clinical use.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
143 views7 pages

Finus 70

The document outlines the features and technologies of the Finus 70 Ultrasound Diagnostic System, highlighting its advanced imaging capabilities through the Harmony Imaging Platform, Micro Flow technology, and various applications such as elastography and tissue Doppler imaging. It emphasizes the system's performance improvements, including enhanced resolution and penetration, as well as ergonomic design elements for user convenience. Additionally, it mentions the integration of remote consultation features and premium in-house technologies for optimal clinical use.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

70

Ultrasound Diagnostic System


Elegance and Excellence
Advanced Platform

Hi Platform
“Harmony Imaging Platform”is the 2nd
generation beamforming technology.
Multiple frames are acquired on every
launch sequence for more detailed Traditional beam-former Multiple beam-former on Hi platform

information.

Micro Flow
Spatial Information

Detect blood flow based on time


information, spatial information, and
parameter information (speed/
Micro Flow off Micro Flow on
energy/ variance).
Parameter Information Time Information Multi-dimension Blood Testing

SNS+
Automatically detect and suppress the
speckle noise based on multi-dimen-
sion algorithm. Acquire and enhance
tissue details from different directions,
easily capture sub-millimeter level
lesion or large organ boarder.

OMG Original Mag Guard


The electromagnetic guard processing

70
Transmit power signal Transmit power signal
of whole system is to prevent the
ultrasonic signal from electromagnetic Adhesive layer

Voltage

Voltage
Resistive layer
interference during the transmission Magnetic layer
PI film

With 16x beamforming and single crystal transducers solution, Finus 70 provides excel- process, to ensure the stability of the
signal transmission, so as to obtain a Time Time

lent performance in both resolution and penetration. clearer image. Unfiltered Filtered power signal Aviation grade electromagnetic absorbing material
Diverse Applications

Elastography Curved AM
Real time elastography is a new noninvasive and painless technique that can Curved Anatomical M-Mode (CAM) technology can show all the spatial and
help determine the hardness of organs and other structures such as breast, temporal relationship of myocardial segment movements during the cardiac
thyroid. Elastic imaging provides users with dynamic visual information and cycle in the scanning sector, which provides a new measurement method to
displays the rigidity of organs, which is helpful for direct and quantitative quantitatively analyze the abnormalities of segmental myocardial motion
diagnosis and treatment. during systolic or diastolic period.

eBiopsy Auto Track


Based on the accurate ultrasonic beam steering and Quickly re-locating ROI box on blood vessel by one
image fusion technology, the needle body can be button.
enhanced to the greatest extent, which can effectively
guide doctors to perform puncture operations.

Tissue Doppler Imaging fAssist


Tissue Doppler Imaging (TDI) is a robust and reproducible echocardiographic Providing tutorial information regarding abdomen,
tool that employs the Doppler effect to assess muscle wall characteristics vascular, small parts, GYN, MSK, etc., including standard
throughout the cardiac cycle including velocity, displacement, deformation, ultrasound image, anatomical diagram, scanning
and event timings. It has permitted a quantitative assessment of both global technique and tips.
and regional function and timing of myocardial events.

Contrast Imaging fRemote/fShare


Pulse inversion contrast-enhanced ultrasound imaging technology can It's easy for doctors to conduct remote consultation by
accurately extract the second harmonic of contrast microbubbles, realize fRemote. And with fShare, users could send images via
contrast-enhanced imaging with high contrast-to-tissue ratio, and provide email, no need installing App on terminals.
more detailed diagnosis for clinic.
Outstanding Clinical Images
Single Crystal Probe

Efficiency improves 85%

Sensitivity increases 6db

Bandwidth increases 25%

In-house Premium Technology


Focus & Fusion provides multiple transducers for different clinical areas of your need
Traditional Piezoelectric Ceramic Single Crystal Probe Technology
Probe Technology

Bonding technique Triple matching layers Micro-elements cutting


By uniform bonding process, adhesive to interconnect ceramic High sensitivity and super bandwidth can be achieved through Byᅠmicro-elements cutting,ᅠone element is cut into several Using a new cutting process, effectively extending the service
life of probe.
and lead is well controlled (max thickness: 1μm) to improve triple matching layers. sub-elements to increase sensitivity and bandwidth of
performance uniformity among elements. transducer.

Sensitivity consistency Traditional

0
40 80 120
Center frequency consistency
Sensitivity increases 6db Conventional Cutting Process Micron Level Anti-chipping Cutting
Technology
0
40 80 120
Bandwidth increases 15%
Backing Layer
Bandwidth Consistency PZT
Triple Matching Layer
Lens

0
40 80 120
Transducers Enhanced Ergonomics

XDiamond

High Definition Monitor Magnesium Shell


15.6 inch high-definition monitor for better Equipped with magnesium alloy shell for
Convex C6-1s Micro-convex MC10-3 Intracavitary EC9-4 visualization better protection
Applications: Abdomen, Applications: Pediatrics, Applications: Obstetrics,
Obstetrics, Gynecology Cardiology Gynecology, Urology

Tilting Probe Holders


Equipped with tilting holders with angle to
avoid damaging when moving the trolley

3 Active Ports
Compact connectors for three active
transducers on trolley
Small Footprint
Linear L12-4 Linear L17-5 HD Linear L13-3 0.25m2 small footprint of trolley to better fit
Applications: Small parts, Applications: Small parts, Applications: Small parts, in narrow space
Vascular, MSK Vascular, MSK Vascular, MSK, Breast

Central Lock Storage Shelves


For locking the trolley’s height with one Storage shelves for users to place their
foot stepping daily-used objects

Phased Array P5-2 Phased Array P8-2 Convex C5-1


Applications: Cardiology, Applications: Abdomen, Applications: Abdomen,
Abdomen, TCD Pediatric cardiology Obstetrics, Gynecology

XDiamond

Phased Array P5-1s Intracavitary EC10-3 Linear L25-10


fAssist fShare fRemote DICOM 3.0 Auto Optimization
Applications: Cardiology, Applications: Obstetrics, Applications: Small parts,
Abdomen, TCD Gynecology, Urology Vascular, MSK
Segurança

Compulsório
KEMENKES RI AKL 21501220469