Q-TECH TESTING LABORATORY
36 St. Augustine St. Oranbo Pasig City
7-000-6850 • qtechlaboratory@gmail.com
Test Report No. TR/PR-25-258
TEST REPORT
The following sample(s) was/were submitted and identified by the client as:
Sample Description : Philcore S-1000 8”
Country of Origin : Philippines
Manufacturer / Client : Phildex Industries & Devt. Corp
Standard Specification : -
Test(s) Required : Burst Pressure Test
Date Sampled : -
Date Received : October 27, 2025
Date Test Started : November 7, 2025
Date Test Completed : November 7, 2025
Test Result : For further details, please refer to the following page(s)
PHOTOGRAPHS OF SAMPLE
SUMMARY OF TEST RESULTS
Test Results
Test Items Test Method
Specimen Failure Pressure
1 2.57 MPa
2 2.78 MPa
Burst Pressure Test ASTM D1599 3 2.97 MPa
4 2.91 MPa
5 2.88 Mpa
Page 1 of 4
Q-TECH TESTING LABORATORY
36 St. Augustine St. Oranbo Pasig City
7-000-6850 • qtechlaboratory@gmail.com
Test Report No. TR/PR-25-258
TEST REPORT
Burst Pressure Test
Number of Test Specimens : Five specimens were received and tested by the laboratory
Conditioning Time : 1 hour at 20°C
Test Conducted : 21°C in liquid bath
Test Results:
Specimens Failure Pressure, MPa Test Time Type of Failure
Specimen 1 2.57 60 to 70 seconds Bursting
Specimen 2 2.78 60 to 70 seconds Bursting
Specimen 3 2.97 60 to 70 seconds Bursting
Specimen 4 2.91 60 to 70 seconds Splitting
Specimen 5 2.88 60 to 70 seconds Bursting
Outside Diameter, mm
Specimens
1 2 3 4 Average
Specimen 1 200.14 199.73 199.45 199.80 199.78
Specimen 2 199.87 199.98 199.84 199.93 199.91
Specimen 3 199.24 199.72 199.94 200.16 199.77
Specimen 4 199.82 200.5 200.30 199.25 199.97
Specimen 5 200.32 200.41 199.53 199.01 199.82
Wall Thickness, mm
Specimens
1 2 3 4 Average
Specimen 1 6.754 6.458 6.500 6.507 6.555
Specimen 2 6.780 6.594 6.446 6.482 6.576
Specimen 3 7.082 6.984 6.885 6.994 6.986
Specimen 4 6.513 6.857 6.453 6.480 6.576
Specimen 5 6.516 6.796 6.509 6.506 6.582
REMARKS:
1. The results relate only to the sample(s) tested as received.
2. The sample description indicated above are quoted solely for the customer’s reference; significance of these codes and
words are not verified by the Laboratory.
3. The technician conducted the test to determine the pipe’s maximum burst pressure by applying pressure until it failed.
4. The graph is available for the four (4) specimens tested during the second day of witness testing. However, the graph for
the first specimen was corrupted and could not be retrieved by the laboratory.
5. The testing was witnessed by:
1. Euxil Askee Basto of SMC
2. Fernando Cabacang of PHILDEX
3. Lea Bianca Albay of MATSON BUILDERS
This Test Report shall not be reproduced except in full, without written approval from Q-Tech Testing Laboratory.
Any unauthorized amendment/correction will invalidate this report.
Approved Noted by :
:
Signatory CRISENCIO L. BORROMEO 10-Nov-2025 RAFFY CLINT S. IGNACIO 10-Nov-2025
Testing Services Head Assistant Lab Manager
Page 2 of 4
Q-TECH TESTING LABORATORY
36 St. Augustine St. Oranbo Pasig City
7-000-6850 • qtechlaboratory@gmail.com
Test Report No. TR/PR-25-258
TEST REPORT
Graphs
Specimen 1
Specimen 2
Specimen 3
Page 3 of 4
Q-TECH TESTING LABORATORY
36 St. Augustine St. Oranbo Pasig City
7-000-6850 • qtechlaboratory@gmail.com
Test Report No. TR/PR-25-258
TEST REPORT
Specimen 4
Specimen 5
Page 4 of 4