Professional Documents
Culture Documents
Process GCs, Continuous Analyzers- PID, FID, IR, TCD, Electrochemical, pH,ORP, T, O2
Model 201-A; Analyzers for total VOCs (total HC) or S Compounds in Air
PID, FID or FPD (S or P) models available; with 5 digit Smart Meter No H2 or air required for PID Fast response-PID- 1 sec. To 90%Rack (19), bench or wall mount enclosures available Class 1 Div. 1 or 2 available for hazardous areas; datalogger & alarms avail. New-Autocal, RS232, 4-20 mA, 2 or 4 pt. Multipoint, Alarm cont. for Power, Pump, PID, FID or FPD out ; Range 0.1 to 3000 ppm Carbon bed breakthrough Total hydrocarbons in air Area monitoring for total hydrocarbons, total S or P or selected inorganic cpds. Stack and incinerator monitoring- sampling systems available Total VOCs in water with optional Model 650 sparging system
-Measure- CO, SO2, H2S, Cl2, HCl, H2, NO, NO2, O2, HCN, CO2, NH3 for worker safety at ppm levels - single component only; Model 1004 for 2-4 Components -NEMA 4 enclosure with 4 digit bright LED digit meter & 4-20 mA output, calibration stored in software- no pots to set, built in pump provides a fast response; dual setpoint, alarms, RS232 for multiple sensors
Model 1000
Model 204
Model 202
VOCs, H2S, SO2, VCM, Cl2, O2, N2, CO, CO2, CH4, C2H2, C2H4, 1,3 BD, HCN, pH, ORP, T
Model 301B
-Automatic GC with self diagnostics and optional MODBUS protocol -Specific (ECD, FPD), Selective (FID, PID) and Universal detectors available -Gas or liquid (heated) valves available -Multipoint (1, 10, 20 ot 30 pt.) for area monitoring- programmable sequencing -2 alarms per channel- high level drivers -Remote control, chromatograms and data collection via bidirectional RS232 -NEMA 12 free standing enclosure with easy access -Class 1 Div. (1 or 2) for hazardous areas -weight 150 pounds -Pilot plants, laboratories, process, stack emissions from ppb to % levels Ambient area or fenceline monitoring from ppm to sub ppb levels Measurement of non-methane HC, chlorinated HC, sulfur compounds, aromatic HC, amines, NH3, H2S, water, etc.; range ppb to%
Model 501B
-A variety of systems are available from 1/8 to 1/2 DIN panel mounts -Measure and/or control pH, ORP, conductivity, T, dissolved O2 -4-20 mA output, dataloggersavailable - pH, conductivity, ion selective, & disssolved O2 electrodes available in industrial configurations -Easy to maintain- designed to reduce maintenance by plant personnel -Range pH- 0.0 to 14.00; -Clean Water Act compliance -pH , ORP ,T, conductivity, dissolved O2 transmitters or Controllers -Effluent monitoring -Municipal water treatment -Analysis of water for process input Monitoring cooling water
Model 600
Local Representative
25 Walpole Park S. Drive, Walpole, MA 02081 T 1 508 660 5001; 1 800 724 5600; F 1 508 660 5040 email sales@hnu.com web address: http/www.processanalyzers.net or www.photoionization.com Products are available for purchase on-line at the PID Store
http://www.hnu.com Stacks, incinerators, ambient air, non methane HC, carbon beds, water, food