50047
SPECIFICATION

No. Date Description Drawn Approved


DATE 10.09.06 No. F-5015-3
Approved Drawn

Leland Limited Incorporated LS (SOF) IF (SOF)

SOF: Signature On File

1/5
Valid on date of printing only. 50047-F5015-3.doc 12/14/2006
Gas Technologies Since 1965.
1 Name
50047

2 Application
This specification applies to the “50047” regulator.

3 Function
The “50047” regulator supplies gas by inserting the Leland gas cylinder in the inlet port.
The “50047” regulator supplies gas from 0 to 19 [psi] by adjusting the dial. (from 0 to 0.13 [MPa])
Secondary pressure is read from the built-in pressure gauge.

4 Technical data

Cylinder Leland gas cylinder

Inlet port Female 5/8-18UNF

Outlet port Female 1/8-27NPT

Outlet pressure range 7 to 19 [psi] (0.05 to 0.13 [MPa])

Pressure gauge scale 0 to 30 [psi] (0 to 0.2 [MPa])


+/-1.5 [psi] (+/-0.01 [MPa])
Pressure gauge precision
(+/-5 [%] (FS: full-scale))
Flow rate 15 [NL/min] or more

Proof pressure (Primary) 7687 [psi] or more (53 [MPa])

Proof pressure (Secondary) 218 or more [psi] (1.5 [MPa])

Safety device (Primary) 5512 +/-580 [psi] (38+/-4 [MPa])

Safety device (Secondary) up to 131 [psi] (0.9 [MPa])

Operating temperature 32 to 104 [Degrees F.] (0 to 40 [Degrees C.])


145 to 2756 (The max filling pressure) [psi]
Operating inlet pressure
(1 to 19 [MPa])
Carbon dioxide gas use flow rate less than
Operating flow rate
12 [NL/min]
Mass Approx. 0.992 [lbs.] (450 [g])

2/5
Valid on date of printing only. 50047-F5015-3.doc 12/14/2006
Gas Technologies Since 1965.
Air, Carbon dioxide (CO2), Nitrogen (N2),
Gas
Helium (He)
Lubrication oil White Vaseline
Standard pressure
(Figure 1)
Characteristic
Standard flow
(Figure 2)
characteristic

5 Style and appearance


As per drawings provided separately; free of scratches and stains.

6 Lot numbers
The lot number is the Die-Marking on the Body.

7 Packaging
As per our standard specification

8 Inspection items
- Pressure characteristics
- Flow characteristics
- Leakage at operating pressure.
- Safety device characteristics
- Strength
- Appearance, measurement

9 Notes
A Use a specified gas cartridge.
B Store the regulator and cylinder, between 32 and 104 degrees F. (0, 40 C)
C Do not remove the gas cylinder until the gas has been completely expelled.
D Gas cylinders get cold after use. Do not remove the gas cylinder with your bare hand. In
case of carbon dioxide, wrap cylinder with cloth, and remove it from regulator.
E Do not drop, and do not hit.
F Regulator is adjusted precisely. Do not do disassemble or alter regulator.
G The regulator is not waterproof. If it gets wet, dry completely and use as normal.

3/5
Valid on date of printing only. 50047-F5015-3.doc 12/14/2006
Gas Technologies Since 1965.
H Protect the outlet of the regulator with a check valve when
using a substance such as corrosive or adhesive fluid that
may adversely affect the regulator function.
I If using carbon dioxide, use the regulator in a range as
shown.
Liquid carbon dioxide entering the valve body may cause
inaccurate results or secondary safety device to release.
J To set the regulator pressure, make sure the gas is flowing.
(Setting the pressure without releasing gas will provide
inaccurate results.)

10 Warranty
A One year from date of delivery.
B Regulator used for purposes other than those described in this specification or altered in any
way is not covered by this warranty.
C Problems arising from using cylinders other than described in this specification are not
covered by this warranty.

4/5
Valid on date of printing only. 50047-F5015-3.doc 12/14/2006
Gas Technologies Since 1965.
Reference characteristic (N2)
Fig.1 Standard pressure characteristic
Conditions: Secondary pressure is 14.5 [psi] at no flow. (Primary pressure 1450 [psi])

30
Secondary pressure [psi]

20

10

0
3000 2000 1000 0
Primary pressure [psi]

Fig.2 Standard flow characteristic


Conditions: Secondary pressure is 14.5 [psi] at no flow.

30
Primary pressure 1450 [psi]
870 [psi]
290 [psi]
Secondary pressure [psi]

20

10

0
0 50 100
Primary pressure [psi]

5/5