Professional Documents
Culture Documents
GXR, GXV
Single-impeller submersible pumps in chrome-nickel stainless steel, with vertical delivery port. GXR: with open impeller. GXV: with free-flow (vortex) impeller. Motor cooled by the pumped water passing between the motor jacket and the external jacket. Double shaft seal with oil chamber. Minimum dimension and high levels of performance, for use in many different applications, head up to 12,7 m and flow rates up to 220 liters/min.
Applications
GXR: - For clean water containing solids up to 10 mm grain size. - For draining rooms or or emptying tanks. - Extraction of water from ponds, streams or pits and for rainwater collection. - For irrigation purposes. GXV: - For clean or slightly dirty water, containing solids up to 25 mm grain size. - Particularly suitable for liquids with a high solid content. For outdoor use a power supply cable of not less than 10 m should be used in accordance with: EN 60 335-2-41.
Component Pump casing Strainer Impeller Motor jacket Pump jacket Handle Shaft Mechanical seal Seal lubrication oil
Material Chrome-nickel steel AISI 304 Chrome-nickel steel AISI 304 Chrome-nickel steel AISI 304 Chrome-nickel steel AISI 304 Chrome-nickel steel AISI 304 Polypropylene Chrome-nickel steel AISI 303 Ceramic alumina/Carbon/NBR Oil for food/pharmaceutical machinery
Liquid temperature up to 50 C. Maximum immersion depth: 5 m. Minimum water level with float: GXR = 70 mm, GXV = 130 mm. Minimum water level manual operation: GXR = 15 mm, GXV = 30 mm. Continuous duty. 2-pole induction motor, 50 Hz (n = 2900 rpm). GXR, GXV: three-phase 230 V 10%; three-phase 400 V 10%; GXRM, GXVM: single-phase 230 V, with float switch and thermal protector. Incorporated capacitor. Insulation class F. Protection IP X8 (for continuous immersion) Double impregnation humidity-proof dry winding. Constructed in accordance with: EN 60034-1; EN 60335-1, EN 60335-2-41.
Motor
- Other voltages. - Frequency 60 Hz. - Other mechanical seal. - Cable length 10 m. - Vertical magnetic float switch.
GXR
GX R R 13 11
14 12 10
30
GXV
GX GX
H
m 6 4 2 0
H
m 6 4 2 0
GX GX
V2
5-1
V2
5-8 5-6
GX
V2
0 0
m3/h l/min 50
5 100 150
10 200
15 250
0 0
m3/h l/min 50
5 100 150
10 200
15 250
181
GXR, GXV
Performance n = 2900 rpm
3~
GXR 9 GXR 11 GXR 13
1~
GXRM 9 GXRM 11 GXRM 13
P1 kW 0,5 0,7 kW
m3/h l/min
0 0 9 11
3 50 7 9,5
10,2 170 1,7 4,2 5,2 10,2 170 1,5 3,6 4,9
13,2 220
Hm
12,7 11,7 10,7 m3/h l/min 0 0 6 8,2 10 1,2 20 5,7 7,8 9,5 3 50 5,2 7,2 8,7
2 13,2 220
3~
GXV 25-6 GXV 25-8 GXV 25-10
1~
GXVM 25-6 GXVM 25-8 GXVM 25-10
HP 0,5 0,6
0,25 0,33
Hm
2,6
Power supply cable Cable material H05RN-F H07RN-F H05RN-F H07RN-F Section 3G0,75 mm2 3G1 mm2 4G0,75 mm2 4G1 mm2 Length 5m 5m 5m 5m
CEE 7(VII)
Plug
Float switch Cable material H07RN-F H07RN-F NO NO Section 3G1 mm2 3G1 mm2 -
YES YES NO NO
H1
10
4.93.388
25
4.93.411
176
G 1 1/4
ISO 228
G 1 1/4
ISO 228
56 Dimensions mm H H1 - GXRM 9 265 230 300 265 300 265 5 6,2 6,7 (1) kg GXR GXRM 5,2 6,5 7,2
56 Dimensions mm H H1 302 267 337 302 5,1 6,3 6,8 (1) kg GXV GXVM 5,3 6,6 7,3
TYPE GXR 9
GXR 11 - GXRM 11
(1) With cable length: 5 m
GXR 13 - GXRM 13
182
176
H1
GXR, GXV
Installation examples
G 1 1/4
ISO 228
G 1 1/4
ISO 228
On
On
340
375 Off 70
3.93.037/3
Off 130
3.93.037/3
30
3.93.037/3
h min
h max
3.93.037/3
TYPE
TYPE H GXVM 25-6 GF GXVM 25-8 GF GXVM 25-10 GF 302 337 337
183
GXR, GXV
Features
PATENTED
G 1 1/4 vertical, upward delivery port for installation in small pits, without the need for an elbow on the pump.
Handle in polypropylene.
Shaft in chrome-nickel stainless steel. Easy adjustment of the float switch: to allow the adjustement of start/stop pump levels
Motor cooled by the pumped water passing between the motor jacket and the external jacket.
Oil chamber
GXR GXV
Suction strainer with a double row of holes, for extra safety against clogging. GXR: it allows the passage of solids up to 10 mm. Impeller in chrome-nickel stainless steel.
Suction strainer with a double row of holes, for extra safety against clogging. GXV: it allows the passage of solids up to 25 mm.
The double shaft seal with oil chamber separates the motor from the water and provides further protection against accidental operation when dry.
184