TRIAL MIX PROPORTION FOR CONCRETE MIX DESIGN

NAME OF CLIENT : Lanco Infratech LETTER NO.: DATE :


Grade of Mix : M 15 (PCC) Intake Site Date of Casting : 13.01.2010 7 Days Tssting Due : 28 days Testing Due :
Brand & Grade of Cement : Ambuja PPC/01.01.2010 Specific Gravity of Cement : 3.05
Specific Gravity of F.A. : 2.67 Source: Kathjodi Specific Gravity of C.A. : 2.88 Source: Baghua Grading Zone of F.A. : III (Close to Zone II)
28 days/Accelerated Strength of Cement : 42.76 N/mm² Free Surface Moisture of F.A: 0.18 %
Proportion of C.A. : 50 % of 20 mm % + 50 % of 10 mm to get 20 mm full graded
CONCRETE CHARACTERISTICS

Admixture in ltr.
Water Cement

Cement in Kg.
Water in Ltr.

C.A. in kg.

F.A. in kg.
Reference
Specimen
Trial No.

Concrete
Compressive Strength N/mm2
Ratio

Slump in mm
7 days 28 days
20 mm.: kg
Calculated 10 mm: kg 612 kg
0.60 191.6 319.3 -
Value Total : 1310 kg P=33.5 %
1

2 0 mm. 654 kg
Corrected 613.1 kg Under Sanded
- 203.34 319.3 10 mm: 654 kg -
Value P=33.5 % Non Cohesive
Total : 1308 kg
mm.: kg
Calculated mm: kg 664 kg
0.60 187.2 312.0 -
Value Total : 1273 kg P=36 %
2
2 0 mm. 635.5 kg Initial: 93
Corrected 665.2 kg
- 200.31 312.0 10 mm: 635.5 kg - 15 Mins.: 78
Value P=35 %
Total : 1271 kg 30 Mins: 64
TRIALS ARE WITENESSED BY:
FOR O.I.C.& R (P) LTD, FOR LANCO INFRATECH FOR SPAN CONSULTANCY