SAUDI ARAMCO ID/PID - 18-MAY-05 - REV 0 (Standards Cutoff - August 2004)

SAIC NUMBER DATE APPROVED QR NUMBER


SAUDI ARAMCO INSPECTION CHECKLIST
Pre-Cast Posts Receiving Inspection for SSD/1 Fence SAIC-O-1002 18-May-05 CIVIL-
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

EQUIPMENT ID NUMBER(S) EQUIPMENT DESCRIPTION EQPT CODE SYSTEM ID. PLANT NO.

LAYOUT DRAWING NUMBER REV. NO. PURCHASE ORDER NUMBER EC / PMCC / MCC NO.

SCHEDULED INSPECTION DATE & TIME ACTUAL INSPECTION DATE & TIME QUANTITY INSP. MH's SPENT TRAVEL TIME
SAUDI ARAMCO USE ONLY
SAUDI ARAMCO TIP NUMBER SAUDI ARAMCO ACTIVITY NUMBER WORK PERMIT REQUIRED?

SAUDI ARAMCO INSPECTION LEVEL CONTRACTOR INSPECTION LEVEL

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.

09-SAMSS-098
A1 The cement shall be Type I Ordinary Portland Cement.
Sec.4.2.1

Compressive strength of the concrete shall be a minimum of 28 MPa 09-SAMSS-098


A2
(4000 psi) at 28 days when tested in accordance with ASTM C39. Sec. 5.1

09-SAMSS-098
A3 Concrete slump shall not exceed 75 mm.
Sec. 5.2

09-SAMSS-098
A4 The surface shall be smooth and free from honey-combing or blemishes.
Sec. 5.6

The following tolerances shall apply to all the specified dimensions


09-SAMSS-098
A5 Cross Section: + 6 mm (¼ in), - 4 mm (3/16 in)
Sec. 5.7.1
Length: + 38 mm (1-½ in), - 12 mm (½ in)
09-SAMSS-098
A6 Chamfer all edges, 6 mm. Tops shall be rounded.
Sec. 5.7.2
Intermediate posts shall be nominally 125mm x 150mm x 3220mm to the
AA-036754
A7 tapered cranked tops which are another 400mm's in height to their top
Sht. No. 2
barbed wire holes; cranked 450 from vertical with rounded tops.
Straining posts shall be nominally 180mm x 180mm x 3260mm to the
AA-036754
A8 tapered cranked tops which add another 400mm's to their top barbed
Sht. No. 2
wire holes, are cranked at a 450 angle and have rounded tops.
Pre-Cast gate straining posts have the same cross section but no AA-036754
A9
cranked top with square ends and an overall length of 3710mm. Sht. No. 2

Struts are 125mm x 125mm x 3347mm to their short square cranked top, AA-036754
A10
100mm on the short side, cranked at 40 0 from vertical. Sht. No. 2

REMARKS:
Editorial changes for compressive strength & cement type was recommended by CSU/CSD on 11/30/04 to the relevant Standard Committee, to
delete the conflict on concrete issues between SAES-O-101 & 09-SAMSS-098/SAESQ-001.

REFERENCE DOCUMENTS:
1- 09-SAMSS-098 -- Precast Concrete Fence Posts, 30 May 2001
2- AA-036754, Sht. No. 2 -- Concrete Post Details, 3 March 1994

Contractor / Third-Party Saudi Aramco


Construction Representative* PMT Representative
Work is Complete and Ready for Inspection: T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Inspector PID Representative


Performed Inspection Work / Rework May Proceed T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Supervisor Proponent and Others


Quality Record Approved: T&I Witnessed QC Record Reviewed Work Verified
Name, Organization,
Name, Sign and Date:
Initials and Date:

*Person Responsible for Completion of Quality Work / Test Y = YES N = NO F = FAILED