You are on page 1of 9

VMax User Settings UU- Power up UD- Power down SO- Power on/off UC- Battery Check DS - display

information setting (- do- atomizer output voltage -du- battery output voltage -dR - atomizer ohm ) LO- LED on/off Power Adjust Up: 1. Press the button 3 times in a row until "UU" is shown on the display. 2. When UU is shown on the display, leave the button idle for 2 seconds. The display will change to show the last voltage selected. 3. Once the voltage is displayed, each time you press the button the voltage will advance to the next higher setting: 3.1,3.2,3.3 etc. When you reach 6.0, it will rotate back to 3.0 and go up again. 4. When you have reached the desired setting, leave the button idle for 2 seconds. The setting will be saved and VV will resume normal operation. Power Adjust Down: 1. Press the button 4 times in a row until "UD" is shown on the display . 2. When UD is shown on the display , leave the button idle for 2 seconds. The display will change to show the last voltage selected. 4. Once the voltage is displayed, each time you press the button the voltage will advance to the next lower setting: 5.9,5.8,5.7 etc. When you reach 3.0, it will rotate back to 6.0 and go up again. 4. when you have reached the desired setting, leave the button idle for 2 second. The setting will be saved and VV will resume normal operation. Power On/Off: 1. Press the button 5 times in a row until "SO" is shown on the display. 2. When UD is shown on the display, leave the button idle for 2 seconds. The display will show the last setting, on or off . 4. Each time you press the button the display will toggle between on/off. 4. When you have reached the desired setting, leave the button idle for 2 seconds. If you selected "OF" the VV will go into standby mode. Battery Check: 1. Press the button 6 times in a row until UC is shown on the display. 2. When UC is shown on the display, leave the button idle for 2 seconds, the digital display will show your battery voltage measurement.

3. The battery voltage will be displayed for 2 seconds, then the display will turn off. Display Information Setting During Vaping: 1. Press the button 7 times in a row until DS is shown on the display, 2. When DS is shown on the display, leave the button for 2 seconds, the display will show the current setting: DO, DU or DR. 3. Each time you press the button, the setting will toggle among "DO" "DU" or "DR" , 4. When "DO" is chosen, leave the button idle for 2 seconds, the setting will be saved and the display will show your atomizer working output voltage during your vaping; 5. When "DU" is chosen, leave the button idle for 2 second, the setting will be saved and the display will show your battery voltage during your vaping. 6. When "DR" is chosen, leave the button idle for 2 seconds, the setting will be saved and the display will show your atomizer resistance during your vaping. LED On/Off 1. Press the button 8 times in a row until "LO" is shown on the display. 2. When LO is shown on the display, leave the button idle for 2 seconds, the display will show the current setting: ON/OFF . 3. Each time you press the button, the setting will toggle between on/off. 4. When you have reached the desired setting, leave the button idle for 2 seconds. The setting will be saved and VV will resume normal operation. Short Circuit Protection: The display will show the below error code when there is a short circuit: 1. F1: resistance for the heating coil of cartomizer is bigger than 0.5R, or smaller than 1.3R 2. F2: resistance for the heating coil of cartomizer is smaller than 0.5R

USER Manual

You might also like