You are on page 1of 3

Fluid Data

Inlet Gas Pressure P1 Down stream Pressure P2 DP ( P2-P1) Chocked Flow or Non Chocked Flow SP MW
0 NonChockedFlow FP N2 Cv d

Piping Data

Piping Data
Piping Geometric Factor 0.002
Valve Sizing Coefficient at 100%travel for the Assumed valve size

Velocity head
Ek K1 K2 Kb1 Kb2 d D

head
Sigma K is Velocity head losses Resistance Coefficinet of Upstream Fittings Resistance Coefficinet of Upstream Fittings Inlet Bernouli coefficient Outlet Bernouli coefficient Nominal Valve size Internal Diameter of Piping

You might also like