You are on page 1of 2

Infeed Modules Technical Data

Technical data
Table 2-1: Technical data, I/R modules
Internal cooling External cooling Hose cooling Infeed: Rated power (S1) Infeed power (S640%) Infeed peak power Regenerative feed-back: Continuous regenerative feedback power Regenerative feedback peak power Connection data Voltage Frequency Rated current (400V/480V) Input current at 360 VAC Input current for (480V; S640%) Peak current (400V/480V) Connection crosssection, max. Output voltage Output current at 600 VDC Rated current Output current (480V; S6-40%) Peak current Module width Cooling type Internal cooling 6SN 1145 6SN 1146 6SN 1145 KW KW KW KW KW 1BA0.0BA1 1BB0.0BA1 16 21 35 16 35 1BA0.0CA1 1BB0.0CA1 36 47 70 36 70 1BA0.0DA1 1BB0.0DA1 1BB0.0DA1 55 71 91 55 91 1BB0.0EA1 1BB0.0EA1 1BB0.0EA1 80 104 131 80 131 1BB0.0FA1 1BB0.0FA1 1BB0.0FA1 120 156 175 120 175

V Hz A A A A mm2 V A A A mm

3ph. 400 V AC 10 % to 3ph. 480 V AC +6 % 50 to 60 10 % 27/22.5 30 29.6 59/49.2 60.5/50.4 67.3 65.8 117.5/97.9 92.5/77.1 103 99.2 153/127.5 134/111.7 149 145.8 220/183.3 202/168.3 224.5 218.3 294/245

16 600 / 625 / 680 22.1 29.2 48.3 100 Internal separately driven fan Integrated separately driven fan

50

95

95

150

50 65 96.7 200 Internal separately driven fan Integrated separately driven fan

75.8 98.3 125.8 300 Internal separatelydriven fan

110.8 144.2 181.7 300 Mounted fan

166.7 216.7 242.5 300 Mounted fan

External cooling Hose cooling

Fan assembly and mounted fan required Kit for hosing cooling with fan

Cooling type Internal cooling External cooling Hose cooling Efficiency Weights Internal cooling External cooling Hose cooling

W W (int./ext.) W (int./ext.)

320 50/270 0.97

585 50/535 0.975

745 115/630 115/630 0.977

1280 190/1090 190/1090 0.977

1950 290/1660 290/1660 0.978

kg kg kg

10.5 10.5

15.5 15.5

26 26 26

26 26 26

29 29 29

Table 6-4 Technical data, UI modules

Internal cooling External cooling Hose cooling Infeed: Rated power (S1) Infeed power (S640%)

6SN 1145 6SN 1146 6SN 1145

1AA0.0AA1

1AA0.0CA0 1AB0.0CA0

1AA0.0CA0 1AB0.0CA0

KW KW

5 6.5

10 13

28 36

Infeed Modules Technical Data


Infeed peak power Continuous/peak power of the integrated pulsed resistor Connection data: Voltage Frequency V Hz 3ph. 400 V AC 10 % up to 3ph. 480 V AC +6 % 50 to 60 10 % KW KW 10 0.2/10 25 0.3/25 50

Rated current Input current for 360 VAC Peak current Connection cross section, max. Output voltage Output current for 650 VDC Rated current Output current (S640%) Peak current Module width Cooling type Internal cooling External cooling Hose cooling

A A

9.4 12.3

18.2 23.8

48.8 62.5

A mm2

18.8 6 490 to 680 +6 %

38.8 16

87.1 50

A A

7.8 10

15.4 20

43.3 55.8

A mm

15.5 50

38.8 100

77.5 200

Nonventilated Nonventilated

Universal cooling internal/external

Internal separately driven fan Integrated separately driven fan

Cooling type Internal cooling External cooling Hose cooling Efficiency Weights Internal cooling External cooling Hose cooling Kg kg kg 6.5 6.5 9.5 9.5 15.5 15.5 W W (int./ext.) W (int./ext.) 270 270/ 0.985 450 119/331 0.985 745 90/160 0.985

You might also like