P.O. Box 6098, Musaffah, Abu Dhabi - U.A.E.

Tel: +971-2-550-0767 Fax: +971-2-550-0838

ULTRASONIC TESTING REPORT


Date Client Project Job Location Job Description Date of Examination Weld ID Weld Type Material Surface Condition Area of Interest Welding Process Technique Calibration Blocks Equipment Model Manufacturer Serial No. Probe Angle 0 Frequency (MHz) 5 -----API 5L As Cleaned Ground -----Pulse echo V1,V2, STEPWEDGE EPOCH LT OLYMPUS 070152505 Size (mm) 10 02.04.11 CCIC / ADCO BAB THAMAMA G AND HABSHAN 2 DEVELOPMENT 1.8 MMBOPD PROJECT HABSHAN ULTRASONIC THICKNESS TESTING ON PIPELINE 02.04.11 Procedure No. Welder ID Diameter/Length Thickness Drg / Iso No / Line No. Heat Treatment Weld configuration Acceptance Criteria Couplant Probe Type Manufacturer Serial No. GB 61124-28 -----6 MM PLX (0) 419 65A Before ------API 1104 / DEP 61.40.20.30 Paste Twin Cristal Probe Method of Sizing Scanning Overlap RefferencedB 46 6 dB Drop method N/A dB Value Scanning dB + 6 dB T.C After N/A Job no. 1037 Report no. UT/CCC-0016

Sensitivity Setting

1st BWE SET TO 80% OF FSH

RECORDING AND EVALUATION


14.88 (1) 15.20 (8) 15.04 (5)

15.10(4)

15.30 (2)

14.30 (7) 15.00 (3)

15.20 (6)

Technician : Level-II : SANJAY KEDAR Signature :

Contractor QC : Signature:

ADCO : Signature :