PCU re-homing Procedure:

Expansion from 10 to 30 TS: disp_eq pcu gbl 0 disp_nsvc pcu gbl 0 modify_value pcu end_ts 30 gbl 0 y add_nsvc PCU 111 0 111 1920 1920 0 del_nsvc pcu <PCU_NSVC_ID> ; modifying end TS to 30 TS

;This is a dummy NSVC

; deleting existing NSVC ; Adding the NSVC with modified parameters

add_nsvc PCU <PCU_NSVC_ID> 0 <PCU_NSVC_ID> 1920 1920 0 del_nsvc pcu 111 disp_eq pcu gbl 0 disp_nsvc pcu gbl 0 ; Deleting the Dummy NSVC

Example of Expansion: <PCU_NSVC_ID>=22 disp_eq pcu gbl 0 disp_nsvc pcu gbl 0 Device ID for the GBL: 0 The PCU MMS ID: 2 0 The starting timeslot is[start_ts]: 1 The ending timeslot is[end_ts]: 10 The T391 timer is[T391]: 10 The T392 timer is[T392]: 15 The N391 counter is[N391]: 6 The N392 counter is[N392]: 3 The N393 counter is[N393]: 4 The NS access rate (ns_access_rate) is: 640 Site: PCU_0 NS Access Rate: 640 GBL NS-VCI STATUS DLCI BC BE CIR --- ------ ---------- ---- ---- ---- ---0 22 Unblocked 22 640 0 640 modify_value pcu end_ts 30 gbl 0 y COMMAND ACCEPTED add_nsvc PCU 111 0 111 1920 1920 0 COMMAND ACCEPTED

del_nsvc pcu 22

COMMAND ACCEPTED

add_nsvc PCU 22 0 22 1920 1920 0 COMMAND ACCEPTED del_nsvc pcu 111 COMMAND ACCEPTED disp_eq pcu gbl 0 disp_nsvc pcu gbl 0 Device ID for the GBL: 0 The PCU MMS ID: 2 0 The starting timeslot is[start_ts]: 1 The ending timeslot is[end_ts]: 30 The T391 timer is[T391]: 10 The T392 timer is[T392]: 15 The N391 counter is[N391]: 6 The N392 counter is[N392]: 3 The N393 counter is[N393]: 4 The NS access rate (ns_access_rate) is: 1920 [15/09/11 18:03:11] MMI-RAM 0316 [Mohammed] -> Start of Report: Site: PCU_0 NS Access Rate: 1920 GBL NS-VCI STATUS DLCI BC BE CIR --- ------ ---------- ---- ---- ---- ---0 22 Unblocked 22 1920 0 1920

You might also like