LOBBY

2m

6m

LY/LX = 6/3 = 2 2 (2 WAYS SLAB)


Beam size = 250mm x 250 mm
Slab Thickness = 150 mm
All column size = 300 mm x 300mm
Concrete Grade =C 30
112.5 mm Thickness Brickwall = 2.6 k N/ m2
Finishes = 1.0 k N/m2
Density of concrete = 24 k N/m3
EC 2 :
Intensity of imposed load ,qk = 1.5 k N/m2
Table NH 2 page 5 (NH to BS EN 1991 -1-1-1 :2002 )
Slab Selfweight = (24 x 0.15) = 3.6 k N/ m2
q = 3.6 + 1.5+ 1.0+ = 6.1 k N/ m2

LOBBY

PANEL 1

1 unit

= 1/x
= 1/x(1/3 x) = 1/3
IW = mL
= m (3) (1/2)

= 6.1 (1/2 x3xX) (1/3)

= 3m /x

= 3.05 x

PANEL 2

EW= q A

=1/1.5

IW = mL
= m1 L11
= m(6) (1/1.5) ( + m(6) (1/1.5) = 8m

LOBBY

= (1/1.5) (1/3 x 1.5)


= 0.333 @ 1/3

= (1/1.5) (1/2 x 1.5)


= @ 0.5

= (1/1.5)(1/3 x1.5) = 1/3


= 1/3

EW = q A
= 6.1 (1/2 x1.5x X) (1/3) + 6.1 (1.5 x X)(1/2) +6.1 (1/2 x 1.5 x X) (1/3)
= 1.525 x + 4.575x + 1.525x
= 7.625 x

LOBBY
PANEL 1 = PANEL 4
PANEL 2 = PANEL 3

IW = (3m/x +8m)(2)
= (6m/x +16m )
EW = 3.05 +7.625x

IW = EW
6 m/x + 16m = 3.05 x +7.625 x
6m/x +16m = 3.05x2 + 7.625 x2
m( 6 +16x) = 3.05x2 + 7.625 x2
m = 10.675 x2 / (6 +16 x)

dm/dx =0
u =10.6 + 5x2

v= 6+16 x

u1 = 10.675 x

v1 = 16

dm/dx = (UV1 U1V) / V2


=[ (10.675 x2)(16) (21.35x)(6+16x) ] / (6+ 16x)
= 170.8 x3 -128.1 x 341.6
x = 1.84 or -1.08
: USE x = 1.84 m
m = 10.675 x2/ (6+ 16x)
= 10.675 (1.84)2 / (6+ 16 (1.84))
= 35.464 k N/m