The battery is constructed by plates,
separators, safety valves and container.
Since the electrolyte is held by a glassmat separator and plates, the battery
can be used in any direction and position
(but upside-down should be avoided)
without leakage.
PERFORMANCE SPECIFICATIONS
Nominal Voltage(V)....................................................................................................................12 volts(6cells in series)
Nominal Capacity(Ah)
20 hour rate F.V.(1.75V/cell) (600mA to 10.50volts) ........................................................................................12Ah
10 hour rate F.V.(1.75V/cell) (1140mA to10.50volts) ....................................................................................11.4Ah
5 hour rate F.V.(1.75V/cell) (2040mA to 10.50volts) .....................................................................................10.2Ah
1 hour rate F.V.(1.55V/cell) (7200mA to 9.30volts)..........................................................................................7.2Ah
Approximate Weight................................................................................................................................ 3940g(8.69lbs.)
Terminal
Standard..........................................................................................................................................................Type T2
Optional............................................................................................................................................................Type T1
Internal Resistance (Fully Charged Battery)......................................................................................................
18m
1.5mm..............................................................................................................................98/3.86
Container Height
1.5mm..............................................................................................................................94/3.70
Total Height
2mm.................................................................................................................................98/3.86
0.21
15.0
120
0.18
14.0
100
0.15
13.0
13.0
Charge voltage
2.04A 1.14A
0.6A
3A
10.0
7.2A
9.0
80
60
40
Charge voltage(V)
11.0
Charge current(CA)
Charge volume(%)
Terminal Voltage(V)
12.0
0.12
0.09
0.06
20
0.03
C ha rg e
vo lu m e
1 Discharge
100 %(0.05CA x 20h)
50 %(0.05CA x 10h)
2 Constant voltage charging
Charge voltage:2.275V/cell
Charge current:0.1CA
3 Temperature:20C(68F)
12.0
11.0
10.0
Charge current
8.0
36A 24A
12A
0
5
0
7.0
10
20
30
60
10
20
10
15
20
25
30
Hr
Min
Discharge time
Charging Procedure
Charging
method
Constant
For standby
voltage &
power Source
Constant
current
charging
For
(with current
cycle service restriction)
2.25~2.30
-3
Charging time
O
0.1CA, 20 C
(h)
Temp
O
( C)
100%
discharge
24
0.3
50%
discharge
20
0~40
O
(32~104 F)
2.40~2.50
0.3
-4
16
10
8
6
5
4
Life expectancy(year)
Application
Temperature
Charging
compensation Max. charging
Voltage
current
coefficient of
O
at 20 C
(CA)
voltage
(V/cell) charging
(mV/ OC/cell)
3
2
10
0.5
20
68
30
86
50 oC
122 oF
40
104
Battery temperature
TERMINAL TYPE
mm(inch)
Terminal T1
1.5(5.94
0.06)
98
1.5(3.86
0.8(0.03)
0.06)
6.35(0.25)
4.75(0.19)
98 2(3.86 0.08)
94 1.5(3.7 0 0.6)
151
Discharge time
3.4(0.13)
3.2(0.13)
6.35(0.25)
Terminal T2
7.85(0.31)
0.8(0.03)
OUTER DIMENSIONS
Final Voltage
5Min
10Min
15Min
30Min
10.80V
433.9
319.4
256.0
152.3
87.3
10.50V
502.2
346.0
267.7
158.1
90.0
10.20V
533.6
358.5
276.0
161.7
9.90V
557.5
367.1
282.4
9.60V
576.0
374.4
288.0
5Hr
10Hr
20Hr
35.0
24.1
13.48
7.09
35.7
24.5
13.68
7.20
91.6
36.0
24.6
13.75
7.24
164.0
92.7
36.3
24.7
13.79
7.26
165.6
93.6
36.5
24.8
13.79
7.26
1Hr
3Hr
TERMINAL
POSITION