5-52 INDUSTRIAL VENTILATION
ee
Slots -size for 1000 tom
Moximum plenum velocity
Ye slot velocity
Q = 350 cfn/lineal ft of hood
Hood length = required working space
Bench width= 24" maximum
Duet velocity = 1000 - 3000 tpm
Entry loss=1.78 slot VP 1026 a duct VP
GENERAL VENTILATION, where local exhaust cannot be used:
(Roa, diam |
(3/6 [4500 ~ |
*For toxic materials higher airflows are necessary and operator
may require respiratory protection equipment.
OTHER TYPES OF HOODS
Locol exhaust: See VS- 416.
Booth: For design See VS-45,VS-604
95100 ctm/sq ft of face opening
‘AMERICAN CONFERENCE OF
GOVERNMENTAL INDUSTRIAL HYGIENISTS
WELDING BENCH
406SPECIFIC OPERATIONS 5-53
Flexible duct
PORTABLE _ EXHAUST
Plain duct |Flange or cone)
laches cfm cfm
250
560
1000
Entry lossz 025 duct VE,
Also see "Granite Cutting" VS-909
GENERAL VENTILATION, where local exhaust cannot be used:
(Rod, diam | cim/welder.
52 1000.
SAE 1500.
W4 3500
EZ 4500
For toxic materials higher airflows ore necessary and operator
may require respiratory protection equipment.
OTHER TYPES OF HOODS ‘AMERICAN CONFERENCE OF
Bench: See VS-416 GOVERNMENTAL INDUSTRIAL HYGIENISTS:
Booth: For design See VS-415,VS-604
Q=100 cfm/sq ft of face opening
WELDING BENCH
tox5-54 INDUSTRIAL VENTILATION
Flexible duct
Grinding whee!
Q= 220 cfm for wheels up to 5" diam
300 ctm for wheels 5" to 10" diam
Entry loss = 0.25 VP
Duct velocity = 3500 fom minimum
AMERICAN CONFERENCE OF
GOVERNMENTAL INDUSTRIAL HYGIENISTS.
SURFACE GRINDER
108