CONTENTS
2.1 COMMAND HANDLER APPLICATION (CHA).............................................................................................. ...................- 0 2.1.1 2.1.2 2.1.3 2.2 2.3 2.4 SOME COMMOM MML COMMANDS:...............................................................................................................- 0 EXAMPLE OF EACH:............................................................................................................................................- 0 MORE DETAILED LIST OF MML COMMANDS (CATEGORIZED)................................................................- 0 -
CELLULAR NETWORK ADMINISTRATOR (CNA) .........................................................................................................- 0 ERICSSONS PMR................................................................................................................. ...............................................- 0 ERICSSONS RNO ......................................................................................................... ......................................................- 0 2.4.1 2.4.2 2.4.3 2.4.4 2.5.5 FAS ..........................................................................................................................................................................- 0 FOX .........................................................................................................................................................................- 0 NCS..........................................................................................................................................................................- 0 NOX.........................................................................................................................................................................- 0 MRR.........................................................................................................................................................................- 0 -
3. 3.1 3.2 4.
EXERT/ OSSS ACTIVITY MANAGER...............................................................................................................................- 0 HOW TO SCHEDULE THE DUMP FILE PROCESS: ......................................................................................... ..............- 0 HOW TO LOAD THE COMMAND FILES DIRECTLY (EASIER): ............................................................................... ..- 0 HOW TO DOWNLOAD/USE ALEX
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
1.
INTRODUCTION
This document was compiled with the intent of providing a few working tips and hints for the various radio optimisation tools currently in use by the BCI engineers, working on Ericsson projects. It is not intended to be an operating manual for the tools discussed, although reference is made to other documents, which may provide further information regarding the operating procedures. Please refer to ALEX for further information on the topics discussed here.
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
2. ERICSSONS OSS
This section provides a brief overview of Ericssons Operational Support System (OSS) and is written using OSS R9.1 version. There are some screen-prints and basic procedure descriptions for OSSs Command Handler Application (CHA), Cellular Network Administrator (CNA), and also the Radio Network Optimization (RNO) tools. Remember that all operators have slightly different menu structures for these OSS tools, but that the below procedures will be largely similar. Once the applications are open, the commands etc. are common.
You will need to connect to the parent object of the managed object you wish to interrogate. For example, if you wish to interrogate cell-site 310S4_BRIDGE_VASCO_DA_GAMA, you will need to connect to the BSC called MOI01. Do this by clicking on the Network Element arrow, and selecting your object from the list provided.
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
Using MML Commands: Click in the Input Area of the window, and simply type the command you require. CHA is not case sensitive, and remember to end each command line with a semicolon [;], indicating execute. See the below list for some commonly used MML commands.
What can we do/cant we do? You may or may not have Operator logon status. Care should be taken that if you have Operator logon status you DO NOT EXECUTE ANY SERVICE AFFECTING COMMANDS if you do not have the correct authority or know-how. If you are unsure, only execute commands that PRINT or output information regarding managed objects. (This is indicated by a P at the end of the MML command, e.g. [ALLIP;]).
10. RXMOP:MO=RXOTG-5; 11. RXMOP:MO=RXOCF-5; 12. RLDEP:CELL=202S1_1; 13. RLCFP:CELL=202S1_1; 14. HGSDP:MSISDN=351930109437;
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
___________________________________________________________________________________
___________________________________________________________________________________
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
___________________________________________________________________________________
__________________________________________________________________________________
__________________________________________________________________________________
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
___________________________________________________________________________________
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
___________________________________________________________________________________
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
_________________________________________________________________________________
----------------------------------------------------------------------------------------------------------------------------
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
RLCPP:CELL=xxxx1;
RLNCP:CELL=XXXX1; RLNRP:CELL=XXXX1,CELLR=all; RLSTC:CELL=XXXX1,STATE=halted; RLSTC:CELL=XXXX1,STATE=active; RLSTP:CELL=XXXX1; RLVAP; RLSBP:CELL=XXXX1; RLSBC:CELL=XXXX1,ACC=CLEAR; RXAPE:MO=RXOTG-X,DCP=ALL; RXAPI:MO=RXOTG-X,DEV=RBLT24-XX&&XX,DCP=XX&&-XX; RXAPP:MO=RXOTG-X; RXASP:MO=RXOTG-XX;
RXBLE:MO=RXOTS-XX-X-0&&-7; RXBLI:MO=RXOTS-XX-X-0&&-7; RXELP:MO=RXOTRX-XX-X; RXESE:MO=RXOTS-XX-X-0&&-7; RXESI:MO=RXOTS-XX-X-0&&-7; RXMOP:MO=RXOTG-XX; RXMSP:MO=RXOTG-XX; RXOCF-XX; RXOTF-XX; RXOIS-XX; RXOTRX-XX-X; RXORX-XX-X;
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
RXOTX-XX-X; RXOTS-xx-x-0&&-7; RXMFP:MO=RXOCF-XX,FAULTY; RXTCE:MO=RXOTG-XX,CELL=XXXX1; RXTCI:MO=RXOTG-XX,CELL=XXXX1,CHGR=0; RXTCP:MOTY=RXOTG,CELL=XXXX1; RXTCP:MO=RXOTG-XX; RXTEI:MO=RXOCF-XX; RXALP:MO=RXOTG-XXX,DETAILS; RXALC:MO=RXOTGXXX,MOC=CF,ALSIT=MAINS,ALCLASS=A1; RXLTI:MO=RXOTS-X-0-0&&-7; RXELP:MO=ALL,LOG=ALL; RXMDP:MO=RXOTRX-X-0; RXMDP:MO=RXOTS-X-0-0&&-7; RLSSP:CELL=XXXX1; IMLCT:SPG=0; INFIP:VOL=BTSVOLUMSW; INFIP:FILE=XXXXXXXXX; END; RXMOP:MO=RXOCF-XX; RXPLI;
Print fault information for MO Disconnect TG to cell Connect TG to cell Get TG number for the cell Get cell number for a known TG Test DIP to site. If BTS communication is not possible, DXU is in local Details of BTS alarms Chg MAINS fail alm to A1 MOTY=RXOTG, Loop test of timeslot Transceiver admin error log MO device info:TRH and TRA MO device info:TRH and RBLT Cell system info Check the software being loaded into the the BTS from the IOG. Check that there are subfiles in it. Compare with the DT RXMOI command switch the software version replacement to active
DIP/SNT INFORMATION
DTBLE:DIP=XRBLT; DTBLI:DIP=XRBLT; DTSTP:DIP=XRBLT; DTDIP:DIP=XRBLT; DTQUP:DIP=XRBLT; DTQSP:DIP=XRBLT; DTQSR:DIP=XRBLT,UNACC; ,DEGR; ,BFF or SF or DF; NTBLE:SNT=RTTF1S2-XX; NTBLI:SNT=RTTF1S2-XX; NTCOP:SNT=ETRBLT4-XX,DIPINF; NTTEI:SNT=ETRBLT4-XX; RAPTI:DEV=RALT24-XX; RASAP; Deblock the DIP Block the DIP Status of the DIP Get SNT Number of the DIP Print qual supervn counters for the DIP Print qual supervn parameters for the DIP Clears Unacceptable quality perf ES,SES,DM & T1 Clear degraded quality perf ES2,SES2,DM2&T2 Clears BITFAULTS, SLIPS and DISTURBANCES Deblock the SNT Block the SNT Print dev on that SNT, for all DIP's Test the SNT Initiate call trace on specified device If "Seizure Supervision of Devices in BSC" alarm of RALT24 devices, this command will print those device that have never been used, or are continuously busy Clear the "Seizure Supn of Dev in BSC" alarm Print data on Seizure supervision alarm Print device information for the MO (CF, etc.) This tells what transcoder device and RADIO HANDLER device the MO is connected to, along with RBLT24s Deblock individual transcoder devices
RXTBE:DEV=RTTF1S2-XX;
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
Block individual transcoder devices (actually blocks 5 devices-the one specified and the next 4. The one specified is a MUX and the next 4 are DEMUX) Status of the indiv devices on the DIP Block devices Deblock the devices Print current s/w ver of the SNT Load the software into the SNT Print device data.
TRU FAULT, SPLIT RP: (CF must be Operl, TRX NOOP, BLO=0440 or 0040)
1 2 3 4 5 6 7 RXMSP:MO=RXOTRX-XX-X; RXMDP:MO=RXOTRX-XX-X; RARDP:DEV=RHDEV-XX; FCRWS:RP=X,WS=SEP; BLRPI:RP=X; BLRPE:RP=X; RLCRP:CELL=XXXX1; Status of the TRX Print dev connected to the TRX Print the RP# conn to the RHDEV Split the RP Block the RP Deblock the RP Check to see if sector is back-up
ADDING 2nd TRU: for a regular, or expansion cabinet. Example shows the sector
separation for an expansion. 1 2 3 4 5 RXMOE:MO=RXOTS-XX-X-0&&-7; RXMOE:MO=RXORX-XX-X; RXMOE:MO=RXOTX-XX-X; RXMOE:MO=RXOTRX-XX-X; RXMOI:MO=RXOTRX-XX-X,TEI=tru#, DCP1=XXX,DCP2=XXX&XXX; Delete Delete Delete Delete DEFINE DCP1 & exsisting MO exsisting MO exsisting MO exsisting MO THE TRX, use the following values for DCp2:
TRU# TEI# DCP1 DCP2 0 0 128 129&130 1 1 131 132&133 2 2 134 135&136 3 3 137 138&139 ______________________________________________ Sector A
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
Sector B
4 4 140 141&142 5 5 143 144&145 6 6 160 161&162 7 7 163 164&165 ______________________________________________ Sector C 8 8 166 167&168 9 9 169 170&171 10 10 172 173&174 11 11 175 176&177 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 RXMOC:MO=RXOTRX-XX-X,CELL=XXXX1; RXMOI:MO=RXOTRX-XX-X, BAND=GSM1900,ANT=BETAw,MPWR=45; RXMOC:Mo=RXOTX-XX-X,CELL=XXXX1; RXMOI:MO=RXORX-XX-X,RXD=AB,BAND= GSM1900,ANTA=BETAw,ANTB=ALPHAw; RXMOI:MO=RXORX-XX-X,RXD=B,BAND= GSM1900,ANTA=BETAw; RXMOI:MO=RXOTS-XX-X-0&&7; RXMOP:MO=RXOTRX-XX-X&RXOTX-XX-X& RXORX-XX-X RXAPP:MO=RXOTG-XX; STDEP:DEV=RBLT24-XX&&-XX; RXESI:MO=RXOTRX-XX-X; RXESI:MO=RXOTX-XX-X&RXORX-XXX&RXOTS-XX-X-0&&-7; RXBLE:MO=RXOTX-XX-X&RXORX-XXX&RXOTS-XX-X-0&&-7; RXMSP:MO=RXOTX-XX-X&RXOTX-XXX&RXORX-XX-X&RXOTS-XX-X-0&&-7; RLCRP:CELL=XXXX1; RLCFI:CELL=XXXX1,CHGR=0, DCHNO=channel#; RLCRP:CELL=XXXX1; RLCCC:CELL=XXXX1,SDCCH=1,CHGR=0; RLCRP:CELL=XXXX1; RLSLP:CELL=XXXX1; Assign TRX to cell Define the TX. "w"=A,B or C, depending on the sector!!If MICROCELL use MPWR=33 Assign the TX to the sector Define the RX with diversity. As before "w" = sector FOR MICROCELL ONLY !!Define the RX without diversity Define the timeslots for the TRU Check the definition of TRX, TX & RX Check the devices that support the TRUs, Must have 3 RBLT24 devices for each TRU Check the status of the devices range= 1st RBLT24 from RXAPP + 24) Load the TRX, will come back ORDERED release the terminal Load the rest of the TRU, will come back COM Deblock the MO's in the TRU Check the status of all the MO's in the sector, all must be OPER Check cell resources, must be 1-0-4-7 Define the channel number (from planned works), wait for 10 sec Check the cell resources, must be 1-0-4-15 Increases the SDCCH from 4 to 12, wait for 10sec., then Check cell resource again, must be 1-0-12-14 Check the status of the sector
UNDEFINING TRU
1 2 3 4 5 6 7 8 RXBLI:MO=RXOTS-XX-X-0&&-7; RXBLI:MO=RXORX-XX-X; RXBLI:MO=RXOTX-XX-X; RXBLI:MO=RXOTRX-XX-X; RXESE:MO=RXOTS-XX-X-0&&-7; RXESE:MO=RXORX-XX-X; RXESE:MO=RXOTX-XX-X; RXESE:MO=RXOTRX-XX-X; Block timeslots Block RX Block TX Block TRX Take timeslot out of service Take RX out of service Take TX out of service Take TRX out of service
BCI/RF/03:0014
Date Rev Reference
15/09/2003
R1A
Opt
timeslot RX TX TRX
DELETING A SECTOR
1 2 RLSTC:CELL=cell,STATE=HALTED; RXBLI:MO=RXOTS-XX-XXX-0&&-7; RXBLI:MO=RXOTX-XX-XXX&RXORX-XXXXX&RXOTRX-XX-XXX; RXESE:MO=RXOTS-XX-XXX-0&&-7; RXESE:MO=RXOTX-XX-XXX&RXORX-XXXXX&RXOTRX-XX-XXX; RXMOE:MO=RXOTS-XX-XXX-0&&-7; RXMOE:MO=RXOTX-XX-XXX&RXORX-XXXXX&RXOTRX-XX-XXX; RXTCE:MO=RXOTG-XX,CELL=XXXX1, CHGR=0; RLVLE:CELL=XXXX1,CHTYPE=SDCCH; RLVLE:CELL=XXXX1,CHTYPE=TCH; RLSLE:CELL=XXXX1,PERM; RLDEE:CELL=XXXX1; Change the sector state to HALTED: Disconnect the Transceiver Group:
3 4 5
Disconnect sector from the seizure supervision: Disconnect the supervision of logical channel availability: Delete the sector:
RASAR:DETY=RALT24;
BTS HIERARCHY
1 2 3 4 5 6 7 8 DXU LOAD OR DEBLOCK TG - TRANSCEIVER GROUP CF - CENTRAL FUNCTION TF - TIMING FUNCTION IS - INTERCONNECT SWITCH TRX - TRANSCEIVER CONTROLLER TX - TRANSMITTER RX - RECEIVER TS - TIMESLOTS 1 2 3 4 5 6 7 8 TXU UNLOAD OR BLOCK TS - TIMESLOT RX - RECEIVER TX - TRANSMITTER TRX - TRANSCEIVER CONTROLLER IS - INTERCONNECT SWITCH TF - TIMING FUNCTION CF - CENTRAL FUNCTION TG - TRANSCEIVER GROUP
TXU
DXU
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
The important thing to realize with this tool is that you have the ability to make changes to a PLANNED AREA (i.e. not the live network) and then run consistency checks on this PLANNED AREA before completing an UPDATE JOB, which will write your changes to the BSS network. It is therefore very important to be absolutely clear which AREA you are working in (as showed by the Current Selection button above). The advantage of using CNA over MML commands (in either WinFIOL or CHA), is that if you change a BCCH in CNA for example, the application updates internal and external neighbours, and Measurement Frequency lists (Idle and Active) automatically. In the Command Handler CHA you have to remember to write commands for all of these changes manually.
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
OPEN NEW PLANNED AREA: To ensure that the tool is updated with the live network, always start by right-clicking on menu options File -> New Job -> Adjustment Job. Give your job a name, ensure the other settings are as in the below window, and select the New button:
Then select menu option File -> New Area -> Planned Area, give your new Planned Area a name, and hit the New button. To view the cells and their parameters select your BSC by clicking on the BSC button, then select menu option View -> Cells -> Internal -> All. MAKE YOUR CHANGES: Select the individual cell you want to change, or right-click on any and Select All. Then select menu option View -> Objects in Table -> select either one of the predefined views, or a custom
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
view as in the below screen-print. Hint: In any view, you can view the parameter you are looking for by selecting menu option Column -> Unhide and selecting your parameter.
Data can be edited directly on the table, or to select an entire row, change the first cell, select the entire column by clicking in the parameter name at the top of the column, and then double (left) click the cell below your change. In the below example, the MFRMS parameter for all cells in BSC0 has been changed from 5 to 4 for all cells.
Dont forget to select menu option Edit -> Apply your changes.
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
INCONSISTANCY CHECKER: You should always run a consistency check of your new planned area to identify any inconsistencies. This is done by clicking the menu options File -> New Job -> Consistency Check Job. (You have the option of selecting a consistency check file, or you can edit your own by first selecting menu option Options -> Consistency Check Preferences.)
UPDATE JOB: Once you are happy that are changes are correct, you can update the BSC with your planned area. This is done by selecting menu options File -> Open -> Planned Area -> My Own. Select your Planned Area. Now select File -> New Job -> Update Job (Schedule) or Update Job (Immediate), depending on whether your changes are service affecting or not.
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
2.4.1
FAS
Right-click on the OSS Menu option -> Right click on Configuration management -> Radio Network Optimization (RNO) and you will be presented with the following screen:
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
From here you can select menu option File -> New Recording -> FAS/FOX/NCS/NOX or MRR. Select FAS. Again, you will be presented with the following screen, in which you can enter a Recording Name, select to create a new ICDM, select the Uplink Frequencies and the Cell Sets, and schedule a time to run the recording.
The results can be viewed by clicking on the file name in RNOs Recording Results window, or exported using menu option File > Export Tab Separated Files.
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
2.4.2 FOX
From the RNO screen you can select menu option File -> New Recording -> FAS/FOX/NCS/NOX or MRR. Select FOX. Again, you will be presented with the following screen, in which you can enter a Recording Name, select to create a new ICDM, select the Uplink Frequencies and the Cell Sets, and schedule a time to run the recording.
The results can be viewed by clicking on the file name in RNOs Recording Results window, selecting menu option Reports >FOX -> FOX Change Order Recommendation. The window below shows an example of a change-recommendation.
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
2.4.3 NCS
From the RNO screen you can select menu option File -> New Recording -> FAS/FOX/NCS/NOX or MRR. Select NCS. Again, you will be presented with the following screen, in which you can enter a Recording Name, select a Relative SS or Absolute SS, select the Uplink Frequencies and the Cell Sets, and schedule a time to run the recording.
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
The results can be viewed by clicking on the file name in RNOs Recording Results window, selecting menu option Reports >NCS -> NCS Overview Report or NCS Probable Neighbouring Cell Report, as seen in the below window:
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
2.4.4 NOX
From the RNO screen you can select menu option File -> New Recording -> FAS/FOX/NCS/NOX or MRR. Select NOX. Again, you will be presented with the following screen, in which you can enter a Recording Name, select a Relative SS or Absolute SS, select the Uplink Frequencies and the Cell Sets, and schedule a time to run the recording. Also, the NOX Recommendation selection allows NOX to recommend some neighbour additions/deletions; where as the NOX Automatic actually deletes and adds these neighbour relations automatically.
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
The results can be viewed by clicking on the file name in RNOs Recording Results window, selecting menu option Reports >NOX -> NOX Change Order Recommendation or NOX Change Order Evaluation, as seen in the below window:
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
2.5.5MRR
Select menu option File -> New Recording -> FAS/FOX/NCS/NOX or MRR. Select MRR. Again, you will be presented with the MRR screen, in which you can enter a Recording Name, select the Uplink Frequencies and the Cell Sets, and schedule a time to run the recording. The results can be viewed by clicking on the file name in RNOs Recording Results window, selecting menu option Reports >MRR -> MRR Overview Report/MRR Top Ten Chart/MRR Overview Histogram, as seen in the 3 below windows respectively:
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
A new operational order can be scheduled by right-clicking menu option Order -> New -> OPS, which brings up the following window:
By Clicking on the Browse buttons, you can select your Command Files in your home-directory to execute. In the same way select your Network Element, the Time and Date and of course Repetition Period. In the Output window, select the Filename you would like the results sent to.
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
Again, select your Network Element, your Command file, set Function Busy Retry Period to 2 minutes (in case someone else is trying to execute the same command class on the NE when you are), de-select the Not Accepted and Partly Executed as well as the Execution Result options, leave Delayed Response set to asynchronous, and set Immediate Responses to File, adding the name you wish the dump file to be saved under. When you are done, hit Send, and you should see your dump file running on the Command Handler window. Note that the above process can also be used to execute your correction files, after you have processed the dump files using EXERT.
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
4.1
DOWNLOAD DATA-LIBRARY
ALEX can be accessed at http://cpi.al.sw.ericsson.se/alex . After setting your User Preferences (if not sure, select Display All), you will be taken to the main CPI page. Select folder WCDMA Systems R2 and GSM R9.1 -> GSM Radio Network -> Base Station System BSS R9.1 . At this stage you can either access this data directly off the website (Slow!!!) or better still click on the small box to select the latest release of BSS R9.1 and then click on the Download an Icon on the menu bar. You will be prompted to save this, so create a new directory called DATA on your hard-drive to place this file in.
4.2
Secondly, you will need to download the actual engine. This can be done as follows: In the CPI Store webpage listed above (http://cpi.al.sw.ericsson.se/alex) select menu options Tools -> Active Library Explorer -> Explorer Server (Windows), version 6.1 . Save this application to your local drive, and execute.
4.3
Lastly, open the Application, and click on menu option Show User Preferences. In this pop-up window, you can select your browser type, and point the application to your data store, where you have downloaded your library (above)
BCI/RF/03:0014
Date Rev Reference
15/09/2003
15/09/2003
R1A
Opt
4. CONSOLIDATION EXERCISE
After going through the above document, you should be in a position to complete the below tasks. These tasks require access to an OSS server, and the Ericsson Intranet. Refer to ALEX for further information on the below. After going through this list of tasks, you should be more than able to operate effectively on an Ericsson Network Performance Improvement, optimization team, where you will no doubt add value due to your experience with other vendors and tools! 4.1 Download ALEX, and install the application. 4.2 Open CHA and connect to a live NE. Run the MML commands to view (NB only Print commands ending in <P>) Cell Resources Neighbours Cell Description Data Measurement Frequency Lists for both Active and Idle lists Status of all sub-ordinate Managed Objects (MOs) (hint: RLCRP) (hint: RLNRP) (hint: RLDEP) (hint: RLMFP) (hint: RXMSP)
4.3 Open CNA, open a new Planned Area, and add a few internal neighbour relations. Then run a consistency check using CNAs consistency checker. NB DO NOT DO AN UPDATE JOB WITH YOUR CHANGES!!! 4.4 Open and edit your Consistency Check preferences. Save your file for future us. 4.5 Initiate a PMR on your own phone, and set up a few calls. Open this PMR to display your phones specific events and measurement report data. 4.6 Open RNO and initiate a FAS recording. Create a new ICDM and export this to EXCEL format. 4.7 Open a new FOX recording, in Recommendation mode. Check that the recommended changes make sense by referring to the ICDM created in step 4.6 above. 4.8 Create a new NOX recording. Select a small cell set, and enter the correct frequency set. 4.9 Create a new MRR recording on your phone, make a few calls and view the results in Overview Histogram and Overview Report. 4.10 Download EXERT. Apply for the license key and install. Create a command file, execute this by directly sending a Command File to OSS in CHA. Transfer your dumps back to the EXERT application, and process these. Check for inconsistencies, and ensure that the correction files are correct.