Intelligent Moulded Case Circuit Breaker

Description S(D)Z series intelligent moulded case circuit breakers are suitable for AC 50Hz, rated voltage up to 400V, rated insulation voltage 690V, rated current 16-800A. Mainly used to distributing power, protecting circuits and power supply equipment against overload and short circuit protection. Motor protection circuit breakers are used for the start/ stop control, overload and short circuit protection of squirrel-cage motor. Standards GB/T14048.1Low-voltage switchgear and controlgearGeneral rules GB14048.2 Low -voltage switchgear and controlgear Low-voltage circuit breaker GB14048.4 Low -voltage switchgear and controlgearLow-voltage mechanical breaker and motor starter GB14048.5 Low -voltage switchgear and controlgearControl circuit devices and switching elements-Section1- Electromechanical control circuit devices

Specification Short-circuit breaking capacity Rated current Inm(A) Pole Rated insulation voltage (V)/ Impulse withstand voltage (kV)

S(D)Z-100 Y J 32100

S(D)Z-225 Y 225 J

S(D)Z-400 Y 400 3 AC 690 / 8 J

S(D)Z-6 30 Y 630 J Y

S(D)Z-800 J 800

Ultimate short-circuit breaking capacity lcu (kA) Operation short-circuit breaking capacity lcs (kA)

AC 400V AC 400V

50

65

50

70

50

70

50

70

50

70

30

40

30

40

30

40

30

40

30

40

Rated short time connecting capacity lcw(kA)

4/0.3

8/0.3

8/0.3

Protection features

Tripping features

Long-time delay instantaneous delay two section features Long-time delay setting current lr instantaneous setting current >1.05 lr

Long-time delay short-time delayinstantaneous delay three section features

Three section features

Overload alarm Separation function Installation Arcing time (mm) a b c d Front connection Rare connection Plug connection Drawout co nnection
Accessory Undervoltage tripper

(0.6-1.05) lr overload display Separati on function

Vertical/Horizontal installation 50 90 155 82 103 105 165 83 11 0 10 0 12 7 140 257 103 144 70 210 257 103 145 210 257 103 145

Q H R C QT FT F

Installation

Shunt release Auxiliary

contact Alarm contact Electro-cont rol mechanism Rotation handle control mechanism B

CD

CZ

Auxiliary terminal Front connection jointing basbar Maximum wire connection section(mm2) life (times)

35 10000

95 8000

240 5000

2002 3000

2502 3000

5. Mini circuit breaker

Description SDX2-63 series mini circuit breakers are suitable for 50Hz, rated voltage 230V/400V, rated current 1A-63A and used for electrical equipment overload and short circuit protection. The mini circuit breakers are with highly safe, strong breaking capacity, fast movement, and good reliability, long service life, which are suitable for industrial, commercial, and residential buildings and other places. Standards

GB10963 IEC 60898

Rated current lnm(A)

Pole

Neutral

Frequency Hz

Rated voltage V

Rated current A

Rated operating short-circuit current (lcs) Breaking current (A)

instantan eous tripping

Rated current lnm(A)

cos

230 230/400 1 5 3 610 16 2025 3240

N 50

230

6000

0.650.7

C.D

2 3 4 1 50

230400

400

230 230/400 230 230400 5063 4500 0.750.8 C.D

2 3 4

400