You are on page 1of 1

Commonapplications,usedasaguidetodetermineappropriateTripClass.

Application Standard Heavy HighTorque CentrifugalPump PositivedisplacementPump OffloadConveyor Heavyconveyor Highinertiafan OffloadCompressor LoadedCompressor OffloadMixer HeavyMixer

TripClass 5 10B 20 10 10 5 20 10 5 10 5 20

StartTime(s) Notes 5 12 12 10 12 5 12 23 5 12 5 12 SuitableforStar/Deltaapplicationswith<5sStartime,motor startsoffload SuitableforStar/Deltawithapplications<12sStartime RequiresmorestartingtorquethanaStar/Delta Generallyeasytostartwhenpumpingwater Canbedifficulttostart Unloadedatstart Loadedatstart Generallyfansgreaterorequalto45KW Specialcircuitsensuremotorstartsoffload Somecompressorsystemscanbedifficulttostart Nomaterialinbasin,offload Materialinbasin

GuideoriginallypublishedbyFairfordElectronicsandreproducedbyTheInverterDriveSupermarket.

You might also like