Internal floater should be decided by process. Tank diameter should considered as distance from top angle shall be; - 0.5m for Standard roof - 1.1m for External floater - 1.4m for Internal floater Loading data should be empty weight x 1.1 Description name to be changed Bottom plate to follow API 650 Table 5.1 Roof plate to be change to Cone Roof type or remain Dome roof Cone roof structure/rafter 36.3 x Ar - X 1.05 Walkway weight either - 64kg or only handrail -16kg For external floating roof, roof plate is 0mm Internal floater checked by add up 2 column (or add up 2 weights) Total loading data for Civil & Construction should be X 1.05 for Total weight only. Other change accordingly A573-70 > 13 Do PWHT, if <13 NO A283 GR C > 25 Do PWHT, if <25 NO Area for cone roof is PixDxl 2cos@ Vent size, Foam size & heater to be given by process for tankage. Painting to be consider follow spec. Heating Coil length have to be fit to tank area. Anchor bolt should be consider only if really required. Seismic will caused annular plate become extra thicker.

15 16 17 18 19