SYSTEM DAGNOSIS 44
FI SYSTEM DIAGNOSIS
— CONTENTS
PRECAUTIONS IN SERVICIN
ELECTRICAL PARTS.
FusE.
ECM/VARIOUS SENSORS.
ELECTRICAL CIRCUIT INSPECTION PROCEDURE.
USING THE MULTI-CIRCUIT TESTER.
FISYSTEM TECHNICAL FEATURES.
INJECTION TIME (INJECTION VOLUME)
COMPENSATION OF INJECTION TIME (VOLUME).
INJECTION STOP CONTROL
FI SYSTEM PARTS LOCATION,
FI SYSTEM WIRING DIAGRAM.
ECM TERMINAL
SELF-DIAGNOSIS FUNCTION.
USER MODE:
DEALER MODE.
DIAGNOSTIC TROUBLE CODE TABLE.
| TPS ADJUSTMENT.
FAIL-SAFE FUNCTION.
F1SYSTEM TROUBLESHOOTING.
CUSTOMER COMPLAINT ANALYSIS.
VISUAL INSPECTION.
'SELF-DIAGNOSTIC PROCEDURES.
‘SELF-DIAGNOSIS RESET PROCEDURE.
USE OF SDS DIAGNOSTIC PROCEDURES.
USE OF SDS DIAGNOSIS RESET PROCEDURE
| SHOW DATA WHEN TROUBLE
| (DISPLAING DATA AT THE TIME OF DTC) 7
MALFUNCTION CODE AND DEFECTIVE CONDITION.
"C12" (P0395) CKP SENSOR CIRCUIT MALFUNCTION
“C13” (PO105-H/L) IAP SENSOR CIRCUIT MALFUNCTION.
14” (P0120-H/L) TP SENSOR CIRCUIT MALFUNCTION.
“C15” (PO115-H/L) ECT SENSOR CIRCUIT MALFUNCTION.
"C21" (PO110-H/L) IAT SENSOR CIRCUIT MALFUNCTION...
“C23” (P1651-H/L) TO SENSOR CIRCUIT MALFUNCTION,
"C24" (P0351) IGNITION SYSTEM MALFUNCTION.
“¢31” (P0705) GP SWITCH CIRCUIT MALFUNCTION.
‘€32" (P0201) FUEL INJECTOR CIRCUIT MALFUNCTION.
“G41” (P0230) FP RELAY CIRCUIT MALFUNCTION
“€60" (P0480) COOLING FAN RELAY CIRCUIT MALFUNCTION... 4-5942 SYSTEM DIAGNOSIS
Fl SYSTEM DIAGNOSIS
conreNTs —
SENSORS. 469
KP SENSOR INSPECTION re 460
CKP SENSOR REMOVAL AND INSTALLATION. 4-69
IAP SENSOR INSPECTION. 450
IAP SENSOR REMOVAL AND INSTALLATION. 460
TP SENSOR INSPECTION 460
TP SENSOR REMOVAL AND INSTALLATION. 460
TPS ADJUSTMENT. 460
ECT SENSOR INSPECTION. : 460
ECT SENSOR REMOVAL AND INSTALLATION. +0 |
IAT SENSOR INSPECTION. 461
IAT SENSOR REMOVAL AND INSTALLATION. von 461
TO SENSOR INSPECTION... 461
TO SENSOR REMOVAL AND INSTALLATION... 461FisYSTEMDAGNOSIS 43
risisren onc _o3
PRECAUTIONS IN SERVICING
\Wnen handling te component pats or servicing the Fl system,
‘observe the folowing points for the safety of the system.
ELECTRICAL PARTS
CONNECTOR/COUPLER
‘When connecting a connector, be sure to push it in until a
clicks ft,
+ With a lock type coupler, be sure to release the lock when dis-
connecting, and push in fully to engage the lock when con-
necting
+ When disconnecting the coupler. be sure to hold the coupler
body and do not pul the lead wires.
+ Inspect each tomminal onthe conneetoricoupler for looseness
or bending,
+ Inspect each terminal for corrosion and contamination
‘The terminals must be clean and tree of any foreign material
‘ich could imped proper terminal contac
+ Inspect each lead wie circuit for poor connection by shaking it
by hand light. If any abnormal condition is found, repair or
replace.
+ When taking measurements at electrical connectors using a
tester probe, be sure to insert the probe from the wire harness
side (backside) ofthe connectoricauplr,
‘Coupler
@ Probe