Tech Sheet 127
Tech Sheet 127
This Tech Sheet was developed by the members of the Heat Exchange Institutes (HEI) Closed Feedwater Heater Section. HEI is a trade association comprising the leading manufacturers of heat exchange and vacuum equipment. HEI Tech Sheets are information tools and should not be used as substitutes for instructions from individual manufacturers. Always consult with individual manufacturers for specific instructions regarding their equipment. 9/12/07 Page 1 of 1
This sheet is reviewed periodically and may be updated. Visit www.heatexchange.org for the latest version.
#127
PRESSURE CLASSIFICATION Low Pressure Heater: A heater located (with regard to feedwater flow) between the condensate pump and either the boiler feed pump or, if present, an intermediate pressure (booster) pump. It normally extracts steam from the low pressure turbine. High Pressure Heater: A heater located downstream of the boiler feed pump. Typically, the tubeside design pressure is at least 1500 psig, and the steam source is the high pressure turbine. Intermediate Pressure Heater: (if present). A heater located between the booster pump and the boiler feed pump. Usually the tubeside pressure is within 200-300 psi of the low pressure heaters, and the steam is extracted from an intermediate pressure turbine. ORIENTATION Horizontal: Most heaters are of this configuration. These are the most stable in regard to level control, although they occupy more floor space. Disassembly is by means of either shell or bundle removal. Most are floor mounted, although some are mounted in the condenser exhaust neck. Vertical, Channel Down: Although these conserve floor space, the amount of control area available for liquid level fluctuation is less. Disassembly is by shell removal. Installation and removal may be more difficult than for horizontal heaters. Vertical, Channel Up. These are the least frequently used. Disassembly is by means of bundle removal. If a subcooling zone is present, it must extend the full length of the bundle, since the water must enter the bottom and exit at the top end of the heater. ZONES Zones are separate areas within the shell in a feedwater heater. Condensing Zone: All feedwaters have this zone. All of the steam is condensed in this area, and any remaining non condensable gases must be removed. A large percentage of the energy added by the heater occurs here. Subcooling Zone: (Optional) The condensed steam enters this zone at the saturation temperature and is cooled by convective heat transfer from the incoming feedwater. Desuperheating Zone: (Optional) The incoming steam enters this zone, giving up most of its superheat to the feedwater exiting from the heater.
This Tech Sheet was developed by the members of the Heat Exchange Institutes (HEI) Closed Feedwater Heater Section. HEI is a trade association comprising the leading manufacturers of heat exchange and vacuum equipment. HEI Tech Sheets are information tools and should not be used as substitutes for instructions from individual manufacturers. Always consult with individual manufacturers for specific instructions regarding their equipment. 9/12/07 Page 2 of 2
This sheet is reviewed periodically and may be updated. Visit www.heatexchange.org for the latest version.
#127
This Tech Sheet was developed by the members of the Heat Exchange Institutes (HEI) Closed Feedwater Heater Section. HEI is a trade association comprising the leading manufacturers of heat exchange and vacuum equipment. HEI Tech Sheets are information tools and should not be used as substitutes for instructions from individual manufacturers. Always consult with individual manufacturers for specific instructions regarding their equipment. 9/12/07 Page 3 of 3
This sheet is reviewed periodically and may be updated. Visit www.heatexchange.org for the latest version.