You are on page 1of 109

-

)(**
:)=(c )( )=( x ) /(
:

)/(

M13

M14

M15

M16

M17

M18

-
: = x ) ( x ) (
x)(= /
:

)/(

M13

M14

M15

M16

M17
M18

-
)(x
:)M=PxL 6=(KG.CM
I=B4 12=104 12=833.33 CM4
Y=D
/ 2=10/ 2=5 CM
b=MxY I
:

)/(
,
M13
,
,
M14

,
M15
,

M16
,

M17
,
,
M18
,


CORROSION




.
Wear
.


:
. :

) ( Corrosion Allowance

) (Plastic Deformation Elastic Deformation

) ( Fatigue Strength
)(Cracks ) . (Fast Fracture
. :
.



.
.

. :

.

.

.

. :

.

.




.
. :

. ) ( Stress Corrosion


) ( Hip Joints .


:
:








.






.

.
.

.



.


.


.

.





.

Sunday 04 March 2001 -


Examples Preventive Maintenance

-
Plan of Preventive Maintenance
- Equipments Inventory of
- Equipments Identification of
- Association of Equipments
- Categories Check Lists of Equipments
- Frequencies
- Cafds Preventive Maintenace
- Programm Preventive Maintenance

-

:

.

.
.

.

.

.
.

.

Continous Oparartion Intermimittent Oparation


.
.


.
.

.

Plan of Preventive Maintenance


. .
.
.

.
:
- . Equipments Inventory of
- . Equipments Identification of
- . Association of Equipments

- . Categories Check Lists of Equipments

- . Frequencies

- . Cafds Preventive Maintenace

- . Programm Preventive Maintenance


:

-
.
:
Mechanical Systems
. Air Conditioning Systems & Heating Ventilation
. Sprikler System
Reels System Hose Halon System
. Cold Water System Hot Water
System
. Hydraulic Lifts
Electrical Lifts Elevators Cranes
:
. .
. Substations
Stations Switch . Power Generation System

. . Lightening Protection System


:
. . Fire Alarm System
. . Audio -Visual -System
. . Control System & Automatic Monetoring
. . Telephon System
:
.
.
.
.
.
.
.
:
.
.
. Sewage System .
.
.
Categories :
. . Window Units
. . Packaged Units
. . Split Units
. . Air handling Units

.
.
Record Card
.
.
.


.
.
.

.

-

.
.
.
..
:

PI



-- A-01-7
.
.
:
. ...
. :



.

--
) (
:
-- - -- A-01-7-B-2-19
Identification Card

. .
.

01

19

-


.

Detectors
.
- Association of Equipments
Associated

Items .
Split Unit
:
. Hermetic Compressor Condenser Fan
. Coil Fan Evaporator Fan
Air Filter
. .

. Control .
.
.
.

.


.

.
- Check Lists

Inspection ...

.
.
- Check Lists of Car
.i

Maintenance & Dail Inspection

.ii

.iii

.iv

.v

.vi

.vii

.viii

.ix

-
.i

.ii

.iii

.iv

.v

.vi

.vii

.viii

.ix

.x

.xi

-
.i

.ii

.iii

.iv

.v

.vi

. .

.vii

.viii

.ix

.x

.xi

.xii

.xiii

.xiv

.xv

.xvi

.xvii


.......

:
.i

el. Motor & Compressor

.iii


Motor & Condenser

.iv

.ii

:
.i

.ii

.iii

.iv

.v

.vi

.vii

.viii

.ix

.x

.xi

.xii

:
Maint & Monthly Inspection
. Differential Pressure Gauge
.
.
Maintenance Quartarly Inspection and
. :

. .
. .
. .
Manienance & Semi Annual Inspection
:
. .
. .
Maint & Annual Inspection
. :
. .

. Supply Fan .
. Bearing .
Vibrations .
. .
. .
. .
.
.

. .
.
. Pulley .
. Comprrssor .
.
. .
. .
. { .
.

.
.
. .
. . .
. .
. .
. Evaporator .
. .

:
. Low Pressure Switch & High
.
. Oil Failure SWITCH
.
. Fire Damper Controller
.
. Freeze Start Controller
.
. Motorized Damper .
. Gravity Damper .

. Supply Air Outlets


.
. .

Category .

Packaged Unit
.


. .
.
.



.


.
.


.


.

.


.
.

.
.
.



. Besring Air Handling
Unit

.

.
- Frequencies Definition of Checking



.
:

.

.
.


Production Mass .

.


.
.


.
:

Daily Quarterly

Weekly Semi Annualy

Monthly Semi Annualy

Monthly tow Years Every


- Card Preventive Maintenace

.
:

) (

) (......

.

...... .

......

-
--
.

..... .
:


Power Generator

. .
:

Cliller Water

cooling Tower Water

Chilled Water Pump

Condenser Water Pump

Air Handling Unit



.

.
.

.

.

Over Time
.
Frequencies .
.


.

.

.
--
Scheule Preventie Maintenance

. Week Calendar Msintenance

.

.

-
. .
.
.


.
) (
.

)(

) ( . )
( ) ( .
. ) (
.


.

.

.
.
.
.
Air Handling Units
.

.

-
. Work Load
.



.
-

. Scheduler
.

..... .



. :

....




.
.

.


.

.
.


.
.
.
Mainteance Work Order for Corrective


.
.


-:



.

.

:


.

.


.

.
) (

.

:

.
.
.
) (

) ( .



.

.

:




)(
) (

) (
)
( .

.
.


) (
:

- :
: ) (
: )
(
- -:
) -
(

.

:

.
:

programming
preliminary design
final design
working drawings
construction supervision
:
) ( .
) ( .

)( .
)
( .
.

.
.

.
) ( schematic

-:
.



) (.
.

concept
-:
. plan
. section
elevations
. perspective
.


.

-:


) (
.parcel building site
. main frontage
.
.
-:



.
-:



.

-:


.
.
-:building site
)( parcel
.
-: parcel

. parcel


.

:

. )
( :
.
%

) ( %

.
-:



) ) ( :
.
.

.
.




:



.





.



) (
.


) (

technical

) infrastructure
(

.

:
.
.
.
.
.
) (

.

-:
) (
.

) & (
: ))
) ( (( .

:
:

.
) (
) (
.
)
( .

.

.
:
.
.
)
( .
:
) ( .

.
:


.

:


) ( .
)
(
.
) (

)) ((
.
) (
)
( .

:




.



" " ISO )

(.




.

.
:
:
) ( 4 S
Simplification

.
Standardization

.
Specification

.
Suitability for use.

.
:
:
) (I.S.O " :


"





.
:
) (I.S.O " :
" .



.

.
:

) (I.S.O " :

" .







.


.
:

.
.
.

.

_ .
:

.
:
-

:
.
.
.
- :



.
- :


.
.
- :

:
.
.
- :
.


.

.
- :


.

Reengineering


)(Business Reengineering
) (


.


.


)(Out Box




.


) (

)
:
(.
:

. ) (Fundamental Rethinking
.
. :

. :
.
. ) : (Processes



) (








.


.

" "
) ( .

.


..



.

.

.

* " " SAFE
International
) (American Value Engineers Society of
.

..

.

.

:

..
..
.


*

.
.
.()
.


.
.
.


.
//
.
" "
.
* :
.
.
.
.
.

.
.


*






*


.



.


.


!
.
:

.

.

.
.

.

.

.

.
.

:


.


.

.


.

.


.

.



.



.

umrandsl@nesma.net.sa



.
.
.
.

.
.

.


. .

.
.
.

.

.
.

)(
.

.


.

.
.

.

) ( .


.
. .
.
. )
( .

.
.


.

.

. .
.


)(
.
.
.


.




.
. .

.
.

.
.
. .

.
.


.

.
.

. .
.
.



. :
.
)(.
.
)(

.
.
.
. .

.

. .
.
.
.

. .



.

.







.

":

") . (





.
.
) ( -
,

,
. .


.



. " "

.
" "
.




.




) (

,
) (
,
) (




.


330 cm
H=330 \ 2 = 165 cm
H = 16.5 cm
n = H \ h = 165 \ 16.5 = 10
30 cm
b + 2 * h = 30 + 2 * 16.5 = 63

9 : = L = 9 * 30
270 cm

) ( :
l
2 .7
ht
= 10 . 8 cm
25
25

= 16 cm

ht

l
160
=
10
10

ht

ht=16 cm

:
:

0 .16
* 2500 = 456 .51 Kg \ m 2
cos

1
1
* = 0.5 * 0.3 * 0.165 * 2500
= 206.25Kg \ m2
b
0.3

P = 400 Kg\ m :
) 200 Kg \ m : ( cover
50 Kg \ m :

g = 912.76Kg \ m2
P = 400Kg \ m2
:

* 0.5 * b * h * 2500

0.16 * 2500 = 400 Kg \ m


P = 400 Kg \ m :
) 200 Kg\ m : ( cover
330 * ( 3.3 - 0.16 ) * 3 = :
3108.6 Kg
:

3108 .6
= 647 .625 Kg \ m 2
3 * 1 .6
:

g = 1247.625Kg \ m2
P = 400Kg \ m2



:

ht =16cmd =14cm
b =100cm
M = 61100Kg.cm
X=
d=

6*n*M.
6*15*61100
=
= 2.44cm

(
3
*
1980
+
2
*
15
*
110
)
*
100
(3*s + 2*n*c ) *b

2*M x
+ = 5.36 14

b* x*c 3

x = 1.5 * d 0.5 * 9 * d 2
As =

x
s * (d )
3
use512

24 * M
= 0.8cm
b * c

= 2.24cm2

0.2
cm2
*
100
*
5
.
36
=
1
.
072
100

2
Asmin= max
ASmin=1.68cm \ m
0.12*100*1.4 = 1.68 2
cm
100

M = 210900 Kg .cm
x = 2 . 94 cm
As = 8 . 2 cm 2
use 8 12 mm

:
: B6
: CD ) : ( :
280
L
ht
=
= 20 Cm
14
14
h = 55 cm
:

b = 20 cm

2500*0.5*0.2=250Kg\m :
:
R1=R2=5227Kg\m
:

M=536700
Kg.cm

b=20cm&c =110x=16.17cmd =35.5650cm


x = 10 . 49 cm
2

As = 5 . 82 cm
use 5 14

Q
7608
=
=
=8.95s = 6.9715.84Kg\ cm2
0.85*b*d 0.85*20*50

S = 25cm
use 310mm \ 25 cm
use 28mm \ 25 cm :



_
: -:
) ( .
)( .
)(
) ( .
) ( .
) ( .
. -:
) ( .
)( .
)( .
) ( .
) ( .
) ( .
)( .

- -:
.
.
. .
.

.
.
. -:
-
.

-

.
.

.




.
-


.









.
-
.

- -:



.
- -:



.
- -:
- ....






- .......


.
- :



.
- - :

:



.
.
-:




.
-:
-
.
- :

.

.

.
.
.
. ....

.

. .....

.
. - :
....
- .
- .
. -:
.



.

:
-
.

-

.
. - :
......
. -:
- .
- .
. -:
- .
- .
-

-:



.
- -:

%


.
-:


.


- -:


-:
- .
- .




.
- -:






- -:
- .
- .
-

-
.
-:



....
....



...

-:



.

-:
( .
( .
- .
-


) (
)( ) (



.



.

-:
-:
.
- :



.
.
- -:

.
-:
Strctural analysis of larg panel system

- -:
- -:


- -: :
.
) +
(

) (



) ( -:


) ( -: ) (stairflght ) (
landing
.
) ( -: )
(


.
) ( -:

- -:
)(VL Load
) ( -: :
- .
- :
( finscing (( load)) ) .
.
L.L
.
) ( -: )(Wind
.
) ( -:
-:


.
)
(

)
(twesting moment

.


-:


.
-:
. .
. .
.
. .
. .
.
.
-:


. -:




) ( .
:
.
:

:


)) ((
.
:

:
:

.
....
:
)
(

.
... .


-:
-

.
-

-
) (
.
:



.

. -:



.
. -:
: .
: .

: .
: :
: .
:
.
: .
:
.
:

: . . .
. :
:
))
.

.

.

-:



.




.

.
- :
.
- :

:
- + .
- + .
- + +
.



:


.
- -:




. :



: .


-:

.







.

- :




- :


)


.
- :

.
:
:
)
, : ( )
(



) (
:



) (

:


.

.

- ) (

= =
= =
.

.
- .
= = ) (
= =

.
- :



.
- .

- :

.



)


.


.

) ( .
:



) (


.
:

l
L ...

) (


:
-:
- :
.
- :


:
) (


:




) (
.

.


- :


-


.
- :
.
- .

...


.

) ( :


.





.





.

) : ( :
. .
. .
.
.
. .

) ( :
. .
. .
. .
: :
.




.


) (
:
. .
.

.
.
.


.
.

.
:

.



.
:

:
. .
. .
:

- : .
- .
- :
. .
.
.

. .
. .
. .
. .
. .
. : .
. .
. .


.
.

.
.

) (
.
.


.

MAINTENANCE

:
.


.
:
-

-
.

- .
-
.

:
-

: PREVENTIVE MAINTENANCE

)
(
.


.
-

: CORRECTIVE MAINTENANCE

)
( :
.- )
(.

- .

:

. )
( .

- :
.


.
) (
- . :

.

.
:
.

- :


.

.
: .
- :

) ( .
.
.

.
- :

. )
- (
:
-

.
) . (.

- :





.

.

.

.
:



.
.

) (
.
- -:


) ....... (
.

.
:
- :
:

- .

- :



) ( .

:

): X ( /

:
) ( Shaft Bearing
.
:
= . = / *
- :



.


.

.
.

- :

.

).
) (

.
) - - .
( .
- :

.

.
:

.
). (

- .
- .
- .
- .
- .

:
) ( .
- .


.
.
- :
:

) ( .

:
. .

. .
. .
. .
. .

.
:
.
.
.
.
... .

.
:
:
-

.
- :

)
( .
- :

.
.

/ .................................................... :
.....................................................................:
...................................:
/ ........................: / ................... : ..........:
:
-
-
-
-
-
-
-

-
-
-:
:
:
:

:
:
/ :
.......................... :


. .

. .
. ................. :

:
. .

. .

. .

. ..............:

. .

. .
. ................. :

.:

) )

3

.
) (Average Consumption
) (Instantaneous Consumption
(Peak Factor).

) ...(

) .....).
:

.

:
.
- :
) (
:

/

.
- :



.
(
...( .
- :
.
.
- :

.

:
P = (P1+P2+P3+Pav)/24

P1 :
%.
P2 :
.
P3 :
.
P4 :
.

Pav : .


/
-
-:

. .

.
.



.


.

) ( %
.


.



.

!!!


) (.

) ( Pit Formation
.
.
.


!!..

.


.

.
:


.

. Galvanized Bar
.
.

. Steel Stainless

.
)
membrane

Concrete Joint

.
Concrete Joint :
1. Construction Joint

.
Minimum Shear
.
2. Expansion Joint

.

Horizontal stress


..
2
.
.
3. Settlement Joint
Vertical Displacement


.
4. Isolation Joints

.
5. Control Joint


6. Pressure Reliving Joint
.