You are on page 1of 34

NTC thermistors for

temperature measurement
Miniature sensors
with bendable wires

Series/Type:
Date:

B57861
March 2006

EPCOS AG 2006. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without EPCOS' prior express consent is prohibited.

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

Applications
Heating systems
Industrial electronics
Automotive electronics

Dimensional drawing

Features
Fast response
High measuring accuracy
Different tolerances available
Epoxy resin encapsulation
PTFE-insulated leads of silver-plated
nickel wire, AWG 30
UL approval (E69802)
Options
Non-standard lead lengths.
Also available with close B value tolerance.
Delivery mode
Bulk

Dimensions in mm
Approx. weight 60 mg

General technical data


Climatic category
(IEC 60068-1)
For types with close B value tolerance 0.3%
Max. power
(at 25 C)
Resistance tolerance
Rated temperature
Dissipation factor
(in air)
Thermal cooling time constant
(in air)
Heat capacity

Please read Important notes and


Cautions and warnings at the end of this document.

P25
RR/RR
TR
th
c
Cth

Page 2 of 34

55/155/56
40/100/56
60
1, 3, 5
25
approx. 1.5
approx. 15
approx. 22.5

mW
%
C
mW/K
s
mJ/K

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

Electrical specification and ordering codes


R25

No. of R/T
characteristic

B25/100
K

B value tolerance = 0.3%, resistance tolerance = 1%


8016
3988 0.3%
5k
8016
3988 0.3%
10 k
8018
3964 0.3%
30 k
B value tolerance = 1.0%, resistance tolerance = 1%, 3% or 5%
1008
3560 1%
2k
8016
3988 1%
3k
8016
3988 1%
5k
8016
3988 1%
10 k
8018
3964 1%
30 k
2901
3760 1%
50 k
2014
4540 1%
100 k

Ordering code

B57861S0502F045
B57861S0103F045
B57861S0303F045
B57861S0202+040
B57861S0302+040
B57861S0502+040
B57861S0103+040
B57861S0303+040
B57861S0503+040
B57861S0104+040

+ = Resistance tolerance
F = 1%
H = 3%
J = 5%

Reliability data
Test

Standard

Storage in
dry heat

IEC
60068-2-2

Storage in damp
heat, steady state
Rapid temperature
cycling
Long-term stability
(empirical value)

Test conditions

Storage at upper
category temperature
T: 155 C
t: 1000 h
IEC
Temperature of air: 40 C
60068-2-78 Relative humidity of air: 93%
Duration: 56 days
IEC
Lower test temperature: 55 C
60068-2-14 Upper test temperature: 155 C
Number of cycles: 100
Temperature: 70 C
t: 10000 h

Please read Important notes and


Cautions and warnings at the end of this document.

Page 3 of 34

R25/R25
(typical)
< 2%

Remarks

< 1%

No visible
damage

< 1%

No visible
damage

< 2%

No visible
damage

No visible
damage

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

R/T characteristics
B57861S0502F045
R/T No.
T (C)

8016
B25/100 = 3988 K, R25 = 5000 , TR = 25 C, RR/RR = 1%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]

(%/K)

40.0
35.0
30.0
25.0
20.0

168250
121300
88500
65185
48535

164600
118800
86767
63973
47679

171900
123790
90232
66396
49391

2.2
2.1
2.0
1.9
1.8

0.3
0.3
0.3
0.3
0.3

6.7
6.4
6.2
6.0
5.8

15.0
10.0
5.0
0.0
5.0

36465
27665
21158
16325
12694

35855
27227
20840
16094
12524

37074
28103
21475
16556
12864

1.7
1.6
1.5
1.4
1.3

0.3
0.3
0.3
0.3
0.3

5.6
5.4
5.3
5.1
5.0

10.0
15.0
20.0
25.0
30.0

9950
7854
6245
5000
4029

9824
7760
6175
4950
3984

10076
7947
6315
5050
4073

1.3
1.2
1.1
1.0
1.1

0.3
0.3
0.2
0.2
0.3

4.8
4.7
4.5
4.4
4.3

35.0
40.0
45.0
50.0
55.0

3266
2664
2184
1802
1493

3227
2630
2156
1777
1472

3304
2697
2213
1826
1514

1.2
1.2
1.3
1.4
1.4

0.3
0.3
0.3
0.4
0.4

4.1
4.0
3.9
3.8
3.7

60.0
65.0
70.0
75.0
80.0

1244
1042
876.0
740.7
629.0

1226
1026
862.2
728.6
618.5

1262
1057
889.8
752.7
639.5

1.5
1.5
1.6
1.6
1.7

0.4
0.4
0.5
0.5
0.5

3.6
3.5
3.4
3.3
3.2

85.0
90.0
95.0
100.0

536.2
458.8
394.3
340.0

526.9
450.7
387.1
333.7

545.4
467.0
401.4
346.3

1.7
1.8
1.8
1.9

0.5
0.6
0.6
0.6

3.2
3.1
3.0
2.9

B57861S0103F045
R/T No.
T (C)
40.0
35.0
30.0
25.0

8016
B25/100 = 3988 K, R25 = 10000 , TR = 25 C, RR/RR = 1%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]
336500
242590
177000
130370

329200
237590
173540
127950

Please read Important notes and


Cautions and warnings at the end of this document.

343800
247590
180470
132790

2.2
2.1
2.0
1.9

Page 4 of 34

0.3
0.3
0.3
0.3

(%/K)
6.7
6.4
6.2
6.0

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

B57861S0103F045
R/T No.
T (C)
20.0

8016
B25/100 = 3988 K, R25 = 10000 , TR = 25 C, RR/RR = 1%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]
1.8
0.3
98782
97070
95358

(%/K)
5.8

15.0
10.0
5.0
0.0
5.0

72929
55330
42315
32650
25388

71710
54454
41681
32187
25048

74148
56206
42949
33113
25727

1.7
1.6
1.5
1.4
1.3

0.3
0.3
0.3
0.3
0.3

5.6
5.4
5.3
5.1
5.0

10.0
15.0
20.0
25.0
30.0

19900
15708
12490
10000
8057

19649
15521
12350
9900
7967

20151
15895
12630
10100
8147

1.3
1.2
1.1
1.0
1.1

0.3
0.3
0.2
0.2
0.3

4.8
4.7
4.5
4.4
4.3

35.0
40.0
45.0
50.0
55.0

6531
5327
4369
3603
2986

6454
5261
4312
3554
2944

6608
5393
4426
3652
3029

1.2
1.2
1.3
1.4
1.4

0.3
0.3
0.3
0.4
0.4

4.1
4.0
3.9
3.8
3.7

60.0
65.0
70.0
75.0
80.0

2488
2083
1752
1481
1258

2451
2051
1724
1457
1237

2525
2115
1780
1505
1279

1.5
1.5
1.6
1.6
1.7

0.4
0.4
0.5
0.5
0.5

3.6
3.5
3.4
3.3
3.2

1072
917.7
788.5
680.0

1054
901.5
774.2
667.4

1091
933.9
802.8
692.6

1.7
1.8
1.8
1.9

0.5
0.6
0.6
0.6

3.2
3.1
3.0
2.9

85.0
90.0
95.0
100.0

B57861S0303F045
R/T No.
T (C)

8018
B25/100 = 3964 K, R25 = 30000 , TR = 25 C, RR/RR = 1%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]

(%/K)

40.0
35.0
30.0
25.0
20.0

907060
663280
489810
365130
274640

887450
649650
480250
358360
269810

926670
676910
499370
371900
279480

2.2
2.1
2.0
1.9
1.8

0.3
0.3
0.3
0.3
0.3

6.4
6.2
6.0
5.8
5.6

15.0
10.0
5.0
0.0

208370
159410
122920
95501

204900
156890
121080
94149

211850
161920
124750
96852

1.7
1.6
1.5
1.4

0.3
0.3
0.3
0.3

5.4
5.3
5.1
5.0

Please read Important notes and


Cautions and warnings at the end of this document.

Page 5 of 34

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

B57861S0303F045
R/T No.
T (C)
5.0

8018
B25/100 = 3964 K, R25 = 30000 , TR = 25 C, RR/RR = 1%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]
1.3
0.3
75744
74745
73745

(%/K)
4.8

10.0
15.0
20.0
25.0
30.0

58911
46745
37332
30000
24253

58168
46189
36914
29700
23982

59654
47300
37749
30300
24523

1.3
1.2
1.1
1.0
1.1

0.3
0.3
0.3
0.2
0.3

4.7
4.6
4.4
4.3
4.2

35.0
40.0
45.0
50.0
55.0

19720
16123
13252
10949
9091

19487
15923
13080
10800
8962

19952
16323
13425
11098
9219

1.2
1.2
1.3
1.4
1.4

0.3
0.3
0.3
0.4
0.4

4.1
4.0
3.9
3.8
3.7

60.0
65.0
70.0
75.0
80.0

7584
6356
5351
4524
3840

7473
6259
5267
4450
3776

7696
6453
5435
4597
3904

1.5
1.5
1.6
1.6
1.7

0.4
0.4
0.5
0.5
0.5

3.6
3.5
3.4
3.3
3.2

85.0
90.0
95.0
100.0

3273
2800
2405
2073

3217
2751
2361
2034

3329
2850
2448
2111

1.7
1.8
1.8
1.9

0.5
0.6
0.6
0.6

3.2
3.1
3.0
2.9

B57861S0202F040
R/T No.
T (C)

1008
B25/100 = 3560 K, R25 = 2000 , TR = 25 C, RR/RR = 1%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]

(%/K)

55.0
50.0
45.0
40.0
35.0

106210
78635
58650
44060
33333

100440
74654
55886
42131
31980

111970
82616
61415
45989
34686

5.4
5.1
4.7
4.4
4.1

0.9
0.8
0.8
0.8
0.7

6.1
6.0
5.8
5.7
5.5

30.0
25.0
20.0
15.0
10.0

25392
19450
15034
11671
9137

24439
18778
14557
11332
8896

26344
20122
15511
12009
9378

3.8
3.5
3.2
2.9
2.6

0.7
0.7
0.6
0.6
0.5

5.4
5.2
5.1
4.9
4.8

5.0
0.0
5.0
10.0

7210
5733
4581
3688

7038
5610
4494
3625

7382
5856
4669
3750

2.4
2.1
1.9
1.7

0.5
0.5
0.4
0.4

4.7
4.5
4.4
4.3

Please read Important notes and


Cautions and warnings at the end of this document.

Page 6 of 34

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

B57861S0202F040
R/T No.
T (C)
15.0
20.0
25.0
30.0
35.0
40.0

1008
B25/100 = 3560 K, R25 = 2000 , TR = 25 C, RR/RR = 1%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]
1.5
0.4
3028
2984
2940
2431
2000
1660
1373
1142

2400
1980
1639
1353
1124

2461
2020
1680
1392
1161

(%/K)
4.1

1.3
1.0
1.2
1.4
1.6

0.3
0.3
0.3
0.4
0.5

4.0
3.9
3.8
3.7
3.6

45.0
50.0
55.0
60.0
65.0

960.3
810.9
683.4
579.0
494.3

943.0
794.9
668.8
565.7
482.1

977.6
826.9
698.0
592.4
506.5

1.8
2.0
2.1
2.3
2.5

0.5
0.6
0.6
0.7
0.8

3.5
3.4
3.3
3.2
3.1

70.0
75.0
80.0
85.0
90.0

423.7
363.9
313.6
271.8
236.4

412.6
353.8
304.5
263.5
228.9

434.7
373.9
322.7
280.1
244.0

2.6
2.8
2.9
3.1
3.2

0.9
0.9
1.0
1.1
1.2

3.1
3.0
2.9
2.8
2.8

95.0
100.0
105.0
110.0
115.0

206.8
181.5
159.3
140.2
123.8

199.9
175.2
153.6
135.0
119.1

213.7
187.7
165.0
145.4
128.5

3.3
3.4
3.6
3.7
3.8

1.2
1.3
1.4
1.5
1.6

2.7
2.6
2.6
2.5
2.4

120.0
125.0
130.0
135.0
140.0

109.6
97.41
86.83
77.44
69.23

105.3
93.47
83.22
74.14
66.20

113.9
101.4
90.44
80.75
72.26

3.9
4.0
4.2
4.3
4.4

1.6
1.7
1.8
1.9
2.0

2.4
2.3
2.3
2.2
2.2

145.0
150.0
155.0

62.10
55.82
50.39

59.32
53.26
48.03

64.88
58.37
52.74

4.5
4.6
4.7

2.1
2.2
2.3

2.1
2.1
2.0

B57861S0202H040
R/T No.
T (C)
55.0
50.0
45.0
40.0
35.0

1008
B25/100 = 3560 K, R25 = 2000 , TR = 25 C, RR/RR = 3%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]
106210
78635
58650
44060
33333

98317
73081
54713
41250
31313

Please read Important notes and


Cautions and warnings at the end of this document.

114100
84189
62588
46871
35352

7.4
7.1
6.7
6.4
6.1

Page 7 of 34

1.2
1.2
1.2
1.1
1.1

(%/K)
6.1
6.0
5.8
5.7
5.5

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

B57861S0202H040
R/T No.
T (C)
30.0
25.0
20.0
15.0
10.0

1008
B25/100 = 3560 K, R25 = 2000 , TR = 25 C, RR/RR = 3%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]
5.8
1.1
26852
25392
23931
5.5
1.0
20511
19450
18389
5.2
1.0
15812
15034
14256
4.9
1.0
12242
11671
11099
4.6
1.0
9561
9137
8713

(%/K)
5.4
5.2
5.1
4.9
4.8

5.0
0.0
5.0
10.0
15.0

7210
5733
4581
3688
2984

6894
5495
4402
3552
2881

7526
5970
4761
3823
3087

4.4
4.1
3.9
3.7
3.5

0.9
0.9
0.9
0.9
0.8

4.7
4.5
4.4
4.3
4.1

20.0
25.0
30.0
35.0
40.0

2431
2000
1660
1373
1142

2352
1940
1606
1326
1101

2510
2060
1713
1420
1183

3.3
3.0
3.2
3.4
3.6

0.8
0.8
0.9
0.9
1.0

4.0
3.9
3.8
3.7
3.6

45.0
50.0
55.0
60.0
65.0

960.3
810.9
683.4
579.0
494.3

923.8
778.7
655.1
554.1
472.2

996.8
843.1
711.7
604.0
516.3

3.8
4.0
4.1
4.3
4.5

1.1
1.2
1.2
1.3
1.4

3.5
3.4
3.3
3.2
3.1

70.0
75.0
80.0
85.0
90.0

423.7
363.9
313.6
271.8
236.4

404.1
346.5
298.2
258.1
224.2

443.2
381.2
329.0
285.6
248.7

4.6
4.8
4.9
5.1
5.2

1.5
1.6
1.7
1.8
1.9

3.1
3.0
2.9
2.8
2.8

95.0
100.0
105.0
110.0
115.0

206.8
181.5
159.3
140.2
123.8

195.8
171.6
150.4
132.2
116.6

217.8
191.4
168.2
148.2
131.0

5.3
5.4
5.6
5.7
5.8

2.0
2.1
2.2
2.3
2.4

2.7
2.6
2.6
2.5
2.4

120.0
125.0
130.0
135.0
140.0

109.6
97.41
86.83
77.44
69.23

103.1
91.52
81.48
72.59
64.82

116.1
103.3
92.18
82.30
73.64

5.9
6.0
6.2
6.3
6.4

2.5
2.6
2.7
2.8
2.9

2.4
2.3
2.3
2.2
2.2

145.0
150.0
155.0

62.10
55.82
50.39

58.07
52.15
47.02

66.12
59.49
53.75

6.5
6.6
6.7

3.0
3.2
3.3

2.1
2.1
2.0

Please read Important notes and


Cautions and warnings at the end of this document.

Page 8 of 34

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

B57861S0202J040
R/T No.
T (C)

1008
B25/100 = 3560 K, R25 = 2000 , TR = 25 C, RR/RR = 5%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]

(%/K)

55.0
50.0
45.0
40.0
35.0

106210
78635
58650
44060
33333

96193
71508
53540
40368
30647

116220
85762
63761
47752
36019

9.4
9.1
8.7
8.4
8.1

1.5
1.5
1.5
1.5
1.5

6.1
6.0
5.8
5.7
5.5

30.0
25.0
20.0
15.0
10.0

25392
19450
15034
11671
9137

23424
18000
13956
10865
8531

27360
20900
16112
12476
9744

7.8
7.5
7.2
6.9
6.6

1.4
1.4
1.4
1.4
1.4

5.4
5.2
5.1
4.9
4.8

5.0
0.0
5.0
10.0
15.0

7210
5733
4581
3688
2984

6750
5381
4311
3478
2821

7670
6085
4852
3897
3147

6.4
6.1
5.9
5.7
5.5

1.4
1.4
1.3
1.3
1.3

4.7
4.5
4.4
4.3
4.1

20.0
25.0
30.0
35.0
40.0

2431
2000
1660
1373
1142

2303
1900
1572
1298
1078

2559
2100
1747
1447
1206

5.3
5.0
5.2
5.4
5.6

1.3
1.3
1.4
1.5
1.6

4.0
3.9
3.8
3.7
3.6

45.0
50.0
55.0
60.0
65.0

960.3
810.9
683.4
579.0
494.3

904.6
762.5
641.4
542.5
462.3

1016
859.3
725.4
615.5
526.2

5.8
6.0
6.1
6.3
6.5

1.7
1.8
1.9
2.0
2.1

3.5
3.4
3.3
3.2
3.1

70.0
75.0
80.0
85.0
90.0

423.7
363.9
313.6
271.8
236.4

395.6
339.3
291.9
252.7
219.5

451.7
388.5
335.3
291.0
253.4

6.6
6.8
6.9
7.1
7.2

2.2
2.3
2.4
2.5
2.6

3.1
3.0
2.9
2.8
2.8

95.0
100.0
105.0
110.0
115.0

206.8
181.5
159.3
140.2
123.8

191.7
168.0
147.2
129.4
114.1

221.9
195.0
171.4
151.0
133.5

7.3
7.4
7.6
7.7
7.8

2.7
2.8
3.0
3.1
3.2

2.7
2.6
2.6
2.5
2.4

120.0
125.0
130.0
135.0

109.6
97.41
86.83
77.44

100.9
89.57
79.74
71.04

118.3
105.3
93.91
83.85

7.9
8.0
8.2
8.3

3.3
3.4
3.6
3.7

2.4
2.3
2.3
2.2

Please read Important notes and


Cautions and warnings at the end of this document.

Page 9 of 34

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

B57861S0202J040
R/T No.
T (C)
140.0
145.0
150.0
155.0

1008
B25/100 = 3560 K, R25 = 2000 , TR = 25 C, RR/RR = 5%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]
69.23
63.43
75.03
8.4
3.8
62.10
55.82
50.39

56.83
51.03
46.02

67.36
60.61
54.76

8.5
8.6
8.7

4.0
4.1
4.3

(%/K)
2.2
2.1
2.1
2.0

B57861S0302F040
R/T No.
T (C)

8016
B25/100 = 3988 K, R25 = 3000 , TR = 25 C, RR/RR = 1%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]

(%/K)

55.0
50.0
45.0
40.0
35.0

288910
201030
141510
100950
72777

271710
189880
134210
96126
69560

306120
212180
148800
105770
75993

6.0
5.5
5.2
4.8
4.4

0.8
0.8
0.7
0.7
0.7

7.4
7.1
6.9
6.7
6.4

30.0
25.0
20.0
15.0
10.0

53100
39111
29121
21879
16599

50936
37646
28123
21196
16129

55264
40576
30119
22562
17069

4.1
3.7
3.4
3.1
2.8

0.7
0.6
0.6
0.6
0.5

6.2
6.0
5.8
5.6
5.4

5.0
0.0
5.0
10.0
15.0

12695
9795
7616
5970
4712

12371
9572
7463
5865
4641

13018
10018
7769
6075
4784

2.5
2.3
2.0
1.8
1.5

0.5
0.4
0.4
0.4
0.3

5.3
5.1
5.0
4.8
4.7

20.0
25.0
30.0
35.0
40.0

3747
3000
2417
1959
1598

3699
2970
2386
1930
1571

3795
3030
2448
1988
1625

1.3
1.0
1.3
1.5
1.7

0.3
0.2
0.3
0.4
0.4

4.5
4.4
4.3
4.1
4.0

45.0
50.0
55.0
60.0
65.0

1311
1081
895.9
746.4
624.9

1286
1058
875.5
728.1
608.5

1335
1103
916.2
764.7
641.4

1.9
2.1
2.3
2.5
2.6

0.5
0.5
0.6
0.7
0.8

3.9
3.8
3.7
3.6
3.5

70.0
75.0
80.0
85.0
90.0

525.6
444.4
377.4
321.7
275.3

510.9
431.2
365.6
311.1
265.8

540.3
457.6
389.2
332.3
284.8

2.8
3.0
3.1
3.3
3.4

0.8
0.9
1.0
1.0
1.1

3.4
3.3
3.2
3.2
3.1

Please read Important notes and


Cautions and warnings at the end of this document.

Page 10 of 34

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

B57861S0302F040
R/T No.
T (C)
95.0
100.0
105.0
110.0
115.0

8016
B25/100 = 3988 K, R25 = 3000 , TR = 25 C, RR/RR = 1%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]
236.6
228.1
245.1
3.6
1.2
204.0
196.4
211.6
3.7
1.3
176.6
169.7
183.4
3.9
1.4
153.4
147.2
159.5
4.0
1.4
133.6
128.1
139.2
4.2
1.5

(%/K)
3.0
2.9
2.9
2.8
2.7

120.0
125.0
130.0
135.0
140.0

116.8
102.5
90.27
79.63
70.44

111.8
97.99
86.18
75.93
67.08

121.8
107.0
94.36
83.34
73.80

4.3
4.4
4.5
4.7
4.8

1.6
1.7
1.8
1.9
2.0

2.7
2.6
2.5
2.5
2.4

145.0
150.0
155.0

62.50
55.59
49.60

59.44
52.81
47.07

65.55
58.37
52.14

4.9
5.0
5.1

2.1
2.2
2.3

2.4
2.3
2.3

B57861S0302H040
R/T No.
T (C)

8016
B25/100 = 3988 K, R25 = 3000 , TR = 25 C, RR/RR = 3%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]

(%/K)

55.0
50.0
45.0
40.0
35.0

288910
201030
141510
100950
72777

265930
185860
131380
94107
68105

311900
216200
151630
107790
77449

8.0
7.5
7.2
6.8
6.4

1.1
1.1
1.0
1.0
1.0

7.4
7.1
6.9
6.7
6.4

30.0
25.0
20.0
15.0
10.0

53100
39111
29121
21879
16599

49874
36864
27540
20758
15797

56326
41358
30702
22999
17401

6.1
5.7
5.4
5.1
4.8

1.0
1.0
0.9
0.9
0.9

6.2
6.0
5.8
5.6
5.4

5.0
0.0
5.0
10.0
15.0

12695
9795
7616
5970
4712

12117
9376
7311
5746
4547

13272
10214
7922
6194
4878

4.5
4.3
4.0
3.8
3.5

0.9
0.8
0.8
0.8
0.8

5.3
5.1
5.0
4.8
4.7

20.0
25.0
30.0
35.0
40.0

3747
3000
2417
1959
1598

3624
2910
2338
1891
1539

3870
3090
2496
2028
1657

3.3
3.0
3.3
3.5
3.7

0.7
0.7
0.8
0.8
0.9

4.5
4.4
4.3
4.1
4.0

45.0

1311

1260

1362

3.9

1.0

3.9

Please read Important notes and


Cautions and warnings at the end of this document.

Page 11 of 34

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

B57861S0302H040
R/T No.
T (C)
50.0
55.0
60.0
65.0

8016
B25/100 = 3988 K, R25 = 3000 , TR = 25 C, RR/RR = 3%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]
4.1
1.1
1125
1081
1037
895.9
857.6
934.1
4.3
1.2
746.4
713.1
779.7
4.5
1.2
624.9
596.0
653.9
4.6
1.3

(%/K)
3.8
3.7
3.6
3.5

70.0
75.0
80.0
85.0
90.0

525.6
444.4
377.4
321.7
275.3

500.3
422.3
358.0
304.7
260.3

550.9
466.5
396.8
338.7
290.3

4.8
5.0
5.1
5.3
5.4

1.4
1.5
1.6
1.7
1.8

3.4
3.3
3.2
3.2
3.1

95.0
100.0
105.0
110.0
115.0

236.6
204.0
176.6
153.4
133.6

223.3
192.3
166.2
144.1
125.4

249.8
215.7
187.0
162.6
141.8

5.6
5.7
5.9
6.0
6.2

1.9
2.0
2.1
2.2
2.3

3.0
2.9
2.9
2.8
2.7

120.0
125.0
130.0
135.0
140.0

116.8
102.5
90.27
79.63
70.44

109.5
95.94
84.37
74.33
65.67

124.1
109.1
96.17
84.93
75.21

6.3
6.4
6.5
6.7
6.8

2.4
2.5
2.6
2.7
2.8

2.7
2.6
2.5
2.5
2.4

145.0
150.0
155.0

62.50
55.59
49.60

58.19
51.70
46.08

66.80
59.48
53.13

6.9
7.0
7.1

2.9
3.0
3.1

2.4
2.3
2.3

B57861S0302J040
R/T No.
T (C)

8016
B25/100 = 3988 K, R25 = 3000 , TR = 25 C, RR/RR = 5%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]

(%/K)

55.0
50.0
45.0
40.0
35.0

288910
201030
141510
100950
72777

260150
181840
128550
92088
66649

317680
220220
154460
109810
78905

10.0
9.5
9.2
8.8
8.4

1.3
1.3
1.3
1.3
1.3

7.4
7.1
6.9
6.7
6.4

30.0
25.0
20.0
15.0
10.0

53100
39111
29121
21879
16599

48812
36082
26958
20320
15465

57388
42140
31284
23437
17733

8.1
7.7
7.4
7.1
6.8

1.3
1.3
1.3
1.3
1.3

6.2
6.0
5.8
5.6
5.4

5.0
0.0

12695
9795

11863
9180

13526
10410

6.5
6.3

1.2
1.2

5.3
5.1

Please read Important notes and


Cautions and warnings at the end of this document.

Page 12 of 34

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

B57861S0302J040
R/T No.
T (C)
5.0
10.0
15.0

8016
B25/100 = 3988 K, R25 = 3000 , TR = 25 C, RR/RR = 5%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]
6.0
1.2
8074
7616
7158
5.8
1.2
6314
5970
5626
5.5
1.2
4972
4712
4452

(%/K)
5.0
4.8
4.7

20.0
25.0
30.0
35.0
40.0

3747
3000
2417
1959
1598

3549
2850
2290
1852
1507

3945
3150
2544
2067
1689

5.3
5.0
5.3
5.5
5.7

1.2
1.1
1.2
1.3
1.4

4.5
4.4
4.3
4.1
4.0

45.0
50.0
55.0
60.0
65.0

1311
1081
895.9
746.4
624.9

1233
1015
839.7
698.2
583.5

1388
1147
952.1
794.6
666.4

5.9
6.1
6.3
6.5
6.6

1.5
1.6
1.7
1.8
1.9

3.9
3.8
3.7
3.6
3.5

70.0
75.0
80.0
85.0
90.0

525.6
444.4
377.4
321.7
275.3

489.8
413.4
350.5
298.2
254.8

561.4
475.4
404.3
345.2
295.8

6.8
7.0
7.1
7.3
7.4

2.0
2.1
2.2
2.3
2.4

3.4
3.3
3.2
3.2
3.1

95.0
100.0
105.0
110.0
115.0

236.6
204.0
176.6
153.4
133.6

218.6
188.2
162.7
141.1
122.7

254.5
219.8
190.5
165.7
144.5

7.6
7.7
7.9
8.0
8.2

2.5
2.6
2.8
2.9
3.0

3.0
2.9
2.9
2.8
2.7

120.0
125.0
130.0
135.0
140.0

116.8
102.5
90.27
79.63
70.44

107.1
93.89
82.57
72.74
64.26

126.5
111.1
97.97
86.52
76.62

8.3
8.4
8.5
8.7
8.8

3.1
3.2
3.4
3.5
3.6

2.7
2.6
2.5
2.5
2.4

145.0
150.0
155.0

62.50
55.59
49.60

56.94
50.59
45.08

68.05
60.59
54.12

8.9
9.0
9.1

3.8
3.9
4.0

2.4
2.3
2.3

B57861S0502F040
R/T No.
T (C)
55.0
50.0
45.0

8016
B25/100 = 3988 K, R25 = 5000 , TR = 25 C, RR/RR = 1%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]
481520
335050
235840

452850
316470
223690

Please read Important notes and


Cautions and warnings at the end of this document.

510200
353630
248000

6.0
5.5
5.2

Page 13 of 34

0.8
0.8
0.7

(%/K)
7.4
7.1
6.9

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

B57861S0502F040
R/T No.
T (C)
40.0
35.0

8016
B25/100 = 3988 K, R25 = 5000 , TR = 25 C, RR/RR = 1%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]
4.8
0.7
176290
168250
160210
4.4
0.7
126660
121300
115930

(%/K)
6.7
6.4

30.0
25.0
20.0
15.0
10.0

88500
65185
48535
36465
27665

84893
62744
46871
35326
26882

92107
67626
50199
37603
28448

4.1
3.7
3.4
3.1
2.8

0.7
0.6
0.6
0.6
0.5

6.2
6.0
5.8
5.6
5.4

5.0
0.0
5.0
10.0
15.0

21158
16325
12694
9950
7854

20619
15954
12438
9775
7735

21696
16696
12949
10125
7973

2.5
2.3
2.0
1.8
1.5

0.5
0.4
0.4
0.4
0.3

5.3
5.1
5.0
4.8
4.7

20.0
25.0
30.0
35.0
40.0

6245
5000
4029
3266
2664

6165
4950
3977
3217
2618

6325
5050
4080
3314
2709

1.3
1.0
1.3
1.5
1.7

0.3
0.2
0.3
0.4
0.4

4.5
4.4
4.3
4.1
4.0

45.0
50.0
55.0
60.0
65.0

2184
1802
1493
1244
1042

2143
1764
1459
1213
1014

2226
1839
1527
1275
1069

1.9
2.1
2.3
2.5
2.6

0.5
0.5
0.6
0.7
0.8

3.9
3.8
3.7
3.6
3.5

70.0
75.0
80.0
85.0
90.0

876.0
740.7
629.0
536.2
458.8

851.4
718.7
609.3
518.5
443.0

900.6
762.7
648.7
553.8
474.7

2.8
3.0
3.1
3.3
3.4

0.8
0.9
1.0
1.0
1.1

3.4
3.3
3.2
3.2
3.1

95.0
100.0
105.0
110.0
115.0

394.3
340.0
294.3
255.6
222.7

380.1
327.3
282.9
245.3
213.5

408.4
352.7
305.7
265.9
231.9

3.6
3.7
3.9
4.0
4.2

1.2
1.3
1.4
1.4
1.5

3.0
2.9
2.9
2.8
2.7

120.0
125.0
130.0
135.0
140.0

194.7
170.9
150.5
132.7
117.4

186.3
163.3
143.6
126.5
111.8

203.0
178.4
157.3
138.9
123.0

4.3
4.4
4.5
4.7
4.8

1.6
1.7
1.8
1.9
2.0

2.7
2.6
2.5
2.5
2.4

145.0
150.0
155.0

104.2
92.65
82.67

109.3
97.28
86.90

4.9
5.0
5.1

2.1
2.2
2.3

2.4
2.3
2.3

99.07
88.02
78.45

Please read Important notes and


Cautions and warnings at the end of this document.

Page 14 of 34

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

B57861S0502H040
R/T No.
T (C)

8016
B25/100 = 3988 K, R25 = 5000 , TR = 25 C, RR/RR = 3%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]

(%/K)

55.0
50.0
45.0
40.0
35.0

481520
335050
235840
168250
121300

443220
309770
218970
156840
113510

519830
360330
252720
179660
129080

8.0
7.5
7.2
6.8
6.4

1.1
1.1
1.0
1.0
1.0

7.4
7.1
6.9
6.7
6.4

30.0
25.0
20.0
15.0
10.0

88500
65185
48535
36465
27665

83123
61440
45901
34597
26329

93877
68930
51169
38332
29001

6.1
5.7
5.4
5.1
4.8

1.0
1.0
0.9
0.9
0.9

6.2
6.0
5.8
5.6
5.4

5.0
0.0
5.0
10.0
15.0

21158
16325
12694
9950
7854

20196
15627
12185
9576
7578

22119
17023
13203
10324
8130

4.5
4.3
4.0
3.8
3.5

0.9
0.8
0.8
0.8
0.8

5.3
5.1
5.0
4.8
4.7

20.0
25.0
30.0
35.0
40.0

6245
5000
4029
3266
2664

6040
4850
3897
3152
2565

6450
5150
4160
3379
2762

3.3
3.0
3.3
3.5
3.7

0.7
0.7
0.8
0.8
0.9

4.5
4.4
4.3
4.1
4.0

45.0
50.0
55.0
60.0
65.0

2184
1802
1493
1244
1042

2099
1728
1429
1189
993.3

2269
1875
1557
1299
1090

3.9
4.1
4.3
4.5
4.6

1.0
1.1
1.2
1.2
1.3

3.9
3.8
3.7
3.6
3.5

70.0
75.0
80.0
85.0
90.0

876.0
740.7
629.0
536.2
458.8

833.9
703.9
596.7
507.8
433.9

918.1
777.5
661.3
564.5
483.8

4.8
5.0
5.1
5.3
5.4

1.4
1.5
1.6
1.7
1.8

3.4
3.3
3.2
3.2
3.1

95.0
100.0
105.0
110.0
115.0

394.3
340.0
294.3
255.6
222.7

372.2
320.5
277.0
240.2
209.0

416.3
359.5
311.6
271.0
236.4

5.6
5.7
5.9
6.0
6.2

1.9
2.0
2.1
2.2
2.3

3.0
2.9
2.9
2.8
2.7

120.0
125.0
130.0
135.0

194.7
170.9
150.5
132.7

182.4
159.9
140.6
123.9

206.9
181.8
160.3
141.6

6.3
6.4
6.5
6.7

2.4
2.5
2.6
2.7

2.7
2.6
2.5
2.5

Please read Important notes and


Cautions and warnings at the end of this document.

Page 15 of 34

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

B57861S0502H040
R/T No.
T (C)
140.0
145.0
150.0
155.0

8016
B25/100 = 3988 K, R25 = 5000 , TR = 25 C, RR/RR = 3%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]
117.4
109.4
125.4
6.8
2.8
104.2
92.65
82.67

96.99
86.16
76.79

111.3
99.14
88.55

6.9
7.0
7.1

2.9
3.0
3.1

(%/K)
2.4
2.4
2.3
2.3

B57861S0502J040
R/T No.
T (C)

8016
B25/100 = 3988 K, R25 = 5000 , TR = 25 C, RR/RR = 5%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]

(%/K)

55.0
50.0
45.0
40.0
35.0

481520
335050
235840
168250
121300

433590
303070
214260
153480
111080

529460
367030
257430
183020
131510

10.0
9.5
9.2
8.8
8.4

1.3
1.3
1.3
1.3
1.3

7.4
7.1
6.9
6.7
6.4

30.0
25.0
20.0
15.0
10.0

88500
65185
48535
36465
27665

81353
60136
44930
33867
25776

95647
70234
52140
39062
29554

8.1
7.7
7.4
7.1
6.8

1.3
1.3
1.3
1.3
1.3

6.2
6.0
5.8
5.6
5.4

5.0
0.0
5.0
10.0
15.0

21158
16325
12694
9950
7854

19772
15301
11931
9377
7421

22543
17349
13457
10523
8287

6.5
6.3
6.0
5.8
5.5

1.2
1.2
1.2
1.2
1.2

5.3
5.1
5.0
4.8
4.7

20.0
25.0
30.0
35.0
40.0

6245
5000
4029
3266
2664

5915
4750
3816
3087
2512

6575
5250
4241
3445
2815

5.3
5.0
5.3
5.5
5.7

1.2
1.1
1.2
1.3
1.4

4.5
4.4
4.3
4.1
4.0

45.0
50.0
55.0
60.0
65.0

2184
1802
1493
1244
1042

2056
1692
1399
1164
972.4

2313
1911
1587
1324
1111

5.9
6.1
6.3
6.5
6.6

1.5
1.6
1.7
1.8
1.9

3.9
3.8
3.7
3.6
3.5

6.8
7.0
7.1
7.3
7.4

2.0
2.1
2.2
2.3
2.4

3.4
3.3
3.2
3.2
3.1

70.0
75.0
80.0
85.0
90.0

876.0
740.7
629.0
536.2
458.8

816.4
689.1
584.1
497.1
424.7

Please read Important notes and


Cautions and warnings at the end of this document.

935.6
792.3
673.9
575.3
493.0

Page 16 of 34

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

B57861S0502J040
R/T No.
T (C)
95.0
100.0
105.0
110.0
115.0

8016
B25/100 = 3988 K, R25 = 5000 , TR = 25 C, RR/RR = 5%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]
394.3
364.3
424.2
7.6
2.5
340.0
313.7
366.3
7.7
2.6
294.3
271.1
317.5
7.9
2.8
255.6
235.1
276.1
8.0
2.9
222.7
204.6
240.9
8.2
3.0

120.0
125.0
130.0
135.0
140.0

194.7
170.9
150.5
132.7
117.4

145.0
150.0
155.0

104.2
92.65
82.67

178.5
156.5
137.6
121.2
107.1
94.90
84.31
75.14

(%/K)
3.0
2.9
2.9
2.8
2.7

210.8
185.2
163.3
144.2
127.7

8.3
8.4
8.5
8.7
8.8

3.1
3.2
3.4
3.5
3.6

2.7
2.6
2.5
2.5
2.4

113.4
101.0
90.21

8.9
9.0
9.1

3.8
3.9
4.0

2.4
2.3
2.3

B57861S0103F040
R/T No.
T (C)

8016
B25/100 = 3988 K, R25 = 10000 , TR = 25 C, RR/RR = 1%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]

(%/K)

55.0
50.0
45.0
40.0
35.0

963050
670100
471690
336500
242590

905700
632940
447380
320420
231870

1020400
707260
496000
352580
253310

6.0
5.5
5.2
4.8
4.4

0.8
0.8
0.7
0.7
0.7

7.4
7.1
6.9
6.7
6.4

30.0
25.0
20.0
15.0
10.0

177000
130370
97070
72929
55330

169790
125490
93743
70652
53765

184210
135250
100400
75206
56895

4.1
3.7
3.4
3.1
2.8

0.7
0.6
0.6
0.6
0.5

6.2
6.0
5.8
5.6
5.4

5.0
0.0
5.0
10.0
15.0

42315
32650
25388
19900
15708

41237
31907
24877
19550
15470

43393
33393
25898
20250
15946

2.5
2.3
2.0
1.8
1.5

0.5
0.4
0.4
0.4
0.3

5.3
5.1
5.0
4.8
4.7

20.0
25.0
30.0
35.0
40.0

12490
10000
8057
6531
5327

12330
9900
7955
6434
5237

12650
10100
8159
6628
5417

1.3
1.0
1.3
1.5
1.7

0.3
0.2
0.3
0.4
0.4

4.5
4.4
4.3
4.1
4.0

45.0

4369

4286

4451

1.9

0.5

3.9

Please read Important notes and


Cautions and warnings at the end of this document.

Page 17 of 34

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

B57861S0103F040
R/T No.
T (C)
50.0
55.0
60.0
65.0

8016
B25/100 = 3988 K, R25 = 10000 , TR = 25 C, RR/RR = 1%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]
2.1
0.5
3678
3603
3528
2.3
0.6
3054
2986
2918
2.5
0.7
2549
2488
2427
2.6
0.8
2138
2083
2028

(%/K)
3.8
3.7
3.6
3.5

70.0
75.0
80.0
85.0
90.0

1752
1481
1258
1072
917.7

1703
1437
1219
1037
886.1

1801
1525
1297
1108
949.3

2.8
3.0
3.1
3.3
3.4

0.8
0.9
1.0
1.0
1.1

3.4
3.3
3.2
3.2
3.1

95.0
100.0
105.0
110.0
115.0

788.5
680.0
588.6
511.2
445.4

760.2
654.6
565.8
490.7
426.9

816.9
705.4
611.4
531.7
463.9

3.6
3.7
3.9
4.0
4.2

1.2
1.3
1.4
1.4
1.5

3.0
2.9
2.9
2.8
2.7

120.0
125.0
130.0
135.0
140.0

389.3
341.7
300.9
265.4
234.8

372.6
326.6
287.3
253.1
223.6

406.0
356.8
314.5
277.8
246.0

4.3
4.4
4.5
4.7
4.8

1.6
1.7
1.8
1.9
2.0

2.7
2.6
2.5
2.5
2.4

145.0
150.0
155.0

208.3
185.3
165.3

198.1
176.0
156.9

218.5
194.6
173.8

4.9
5.0
5.1

2.1
2.2
2.3

2.4
2.3
2.3

B57861S0103H040
R/T No.
T (C)

8016
B25/100 = 3988 K, R25 = 10000 , TR = 25 C, RR/RR = 3%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]

(%/K)

55.0
50.0
45.0
40.0
35.0

963050
670100
471690
336500
242590

886440
619540
437940
313690
227020

1039700
720660
505430
359310
258160

8.0
7.5
7.2
6.8
6.4

1.1
1.1
1.0
1.0
1.0

7.4
7.1
6.9
6.7
6.4

30.0
25.0
20.0
15.0
10.0

177000
130370
97070
72929
55330

166250
122880
91801
69193
52658

187750
137860
102340
76665
58002

6.1
5.7
5.4
5.1
4.8

1.0
1.0
0.9
0.9
0.9

6.2
6.0
5.8
5.6
5.4

5.0
0.0

42315
32650

40391
31254

44239
34046

4.5
4.3

0.9
0.8

5.3
5.1

Please read Important notes and


Cautions and warnings at the end of this document.

Page 18 of 34

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

B57861S0103H040
R/T No.
T (C)
5.0
10.0
15.0

8016
B25/100 = 3988 K, R25 = 10000 , TR = 25 C, RR/RR = 3%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]
4.0
0.8
26406
25388
24369
3.8
0.8
20648
19900
19152
3.5
0.8
16260
15708
15156

(%/K)
5.0
4.8
4.7

20.0
25.0
30.0
35.0
40.0

12490
10000
8057
6531
5327

12081
9700
7793
6304
5130

12899
10300
8321
6759
5524

3.3
3.0
3.3
3.5
3.7

0.7
0.7
0.8
0.8
0.9

4.5
4.4
4.3
4.1
4.0

45.0
50.0
55.0
60.0
65.0

4369
3603
2986
2488
2083

4199
3456
2859
2377
1987

4539
3750
3114
2599
2180

3.9
4.1
4.3
4.5
4.6

1.0
1.1
1.2
1.2
1.3

3.9
3.8
3.7
3.6
3.5

70.0
75.0
80.0
85.0
90.0

1752
1481
1258
1072
917.7

1668
1408
1193
1016
867.7

1836
1555
1323
1129
967.7

4.8
5.0
5.1
5.3
5.4

1.4
1.5
1.6
1.7
1.8

3.4
3.3
3.2
3.2
3.1

95.0
100.0
105.0
110.0
115.0

788.5
680.0
588.6
511.2
445.4

744.4
641.0
554.0
480.4
418.0

832.6
719.0
623.2
542.0
472.8

5.6
5.7
5.9
6.0
6.2

1.9
2.0
2.1
2.2
2.3

3.0
2.9
2.9
2.8
2.7

120.0
125.0
130.0
135.0
140.0

389.3
341.7
300.9
265.4
234.8

364.8
319.8
281.2
247.8
218.9

413.8
363.6
320.6
283.1
250.7

6.3
6.4
6.5
6.7
6.8

2.4
2.5
2.6
2.7
2.8

2.7
2.6
2.5
2.5
2.4

145.0
150.0
155.0

208.3
185.3
165.3

194.0
172.3
153.6

222.7
198.3
177.1

6.9
7.0
7.1

2.9
3.0
3.1

2.4
2.3
2.3

B57861S0103J040
R/T No.
T (C)
55.0
50.0
45.0

8016
B25/100 = 3988 K, R25 = 10000 , TR = 25 C, RR/RR = 5%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]
963050
670100
471690

867180
606140
428510

Please read Important notes and


Cautions and warnings at the end of this document.

1058900
734070
514870

10.0
9.5
9.2

Page 19 of 34

1.3
1.3
1.3

(%/K)
7.4
7.1
6.9

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

B57861S0103J040
R/T No.
T (C)
40.0
35.0

8016
B25/100 = 3988 K, R25 = 10000 , TR = 25 C, RR/RR = 5%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]
8.8
1.3
366040
336500
306960
8.4
1.3
263020
242590
222160

30.0
25.0
20.0
15.0
10.0

177000
130370
97070
72929
55330

162710
120270
89860
67735
51551

191290
140470
104280
78124
59108

8.1
7.7
7.4
7.1
6.8

1.3
1.3
1.3
1.3
1.3

6.2
6.0
5.8
5.6
5.4

5.0
0.0
5.0
10.0
15.0

42315
32650
25388
19900
15708

39545
30601
23861
18754
14842

45085
34699
26914
21046
16574

6.5
6.3
6.0
5.8
5.5

1.2
1.2
1.2
1.2
1.2

5.3
5.1
5.0
4.8
4.7

20.0
25.0
30.0
35.0
40.0

12490
10000
8057
6531
5327

11831
9500
7632
6173
5024

13149
10500
8482
6889
5630

5.3
5.0
5.3
5.5
5.7

1.2
1.1
1.2
1.3
1.4

4.5
4.4
4.3
4.1
4.0

45.0
50.0
55.0
60.0
65.0

4369
3603
2986
2488
2083

4111
3384
2799
2327
1945

4626
3822
3174
2649
2221

5.9
6.1
6.3
6.5
6.6

1.5
1.6
1.7
1.8
1.9

3.9
3.8
3.7
3.6
3.5

70.0
75.0
80.0
85.0
90.0

1752
1481
1258
1072
917.7

1633
1378
1168
994.2
849.4

1871
1585
1348
1151
986.0

6.8
7.0
7.1
7.3
7.4

2.0
2.1
2.2
2.3
2.4

3.4
3.3
3.2
3.2
3.1

95.0
100.0
105.0
110.0
115.0

788.5
680.0
588.6
511.2
445.4

728.6
627.4
542.2
470.2
409.1

848.4
732.6
635.0
552.2
481.7

7.6
7.7
7.9
8.0
8.2

2.5
2.6
2.8
2.9
3.0

3.0
2.9
2.9
2.8
2.7

120.0
125.0
130.0
135.0
140.0

389.3
341.7
300.9
265.4
234.8

357.1
313.0
275.2
242.5
214.2

421.5
370.4
326.6
288.4
255.4

8.3
8.4
8.5
8.7
8.8

3.1
3.2
3.4
3.5
3.6

2.7
2.6
2.5
2.5
2.4

145.0
150.0
155.0

208.3
185.3
165.3

189.8
168.6
150.3

226.8
202.0
180.4

8.9
9.0
9.1

3.8
3.9
4.0

2.4
2.3
2.3

Please read Important notes and


Cautions and warnings at the end of this document.

Page 20 of 34

(%/K)
6.7
6.4

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

B57861S0303F040
R/T No.
T (C)

8018
B25/100 = 3964 K, R25 = 30000 , TR = 25 C, RR/RR = 1%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]

(%/K)

55.0
50.0
45.0
40.0
35.0

2472200
1750300
1253200
907060
663280

2325700
1653700
1189000
863910
634100

2618700
1846900
1317500
950200
692460

5.9
5.5
5.1
4.8
4.4

0.8
0.8
0.8
0.7
0.7

7.0
6.8
6.6
6.4
6.2

30.0
25.0
20.0
15.0
10.0

489810
365130
274640
208370
159410

469940
351510
265270
201890
154910

509680
378740
284020
214850
163900

4.1
3.7
3.4
3.1
2.8

0.7
0.6
0.6
0.6
0.5

6.0
5.8
5.6
5.4
5.3

5.0
0.0
5.0
10.0
15.0

122920
95501
74745
58911
46745

119800
93336
73245
57877
46038

126030
97666
76244
59944
47451

2.5
2.3
2.0
1.8
1.5

0.5
0.5
0.4
0.4
0.3

5.1
5.0
4.8
4.7
4.6

20.0
25.0
30.0
35.0
40.0

37332
30000
24253
19720
16123

36855
29700
23945
19428
15851

37808
30300
24561
20012
16395

1.3
1.0
1.3
1.5
1.7

0.3
0.2
0.3
0.4
0.4

4.4
4.3
4.2
4.1
4.0

45.0
50.0
55.0
60.0
65.0

13252
10949
9091
7584
6356

13002
10721
8885
7399
6189

13502
11177
9297
7770
6523

1.9
2.1
2.3
2.4
2.6

0.5
0.6
0.6
0.7
0.8

3.9
3.8
3.7
3.6
3.5

70.0
75.0
80.0
85.0
90.0

5351
4524
3840
3273
2800

5201
4390
3720
3166
2704

5500
4657
3960
3380
2896

2.8
3.0
3.1
3.3
3.4

0.8
0.9
1.0
1.0
1.1

3.4
3.3
3.2
3.2
3.1

95.0
100.0
105.0
110.0
115.0

2405
2073
1792
1555
1354

2319
1995
1723
1493
1298

2491
2150
1862
1618
1410

3.6
3.7
3.9
4.0
4.1

1.2
1.3
1.3
1.4
1.5

3.0
2.9
2.9
2.8
2.7

120.0
125.0
130.0
135.0

1182
1036
910.0
801.7

1132
990.3
868.9
764.6

1233
1081
951.0
838.9

4.3
4.4
4.5
4.6

1.6
1.7
1.8
1.8

2.7
2.6
2.6
2.5

Please read Important notes and


Cautions and warnings at the end of this document.

Page 21 of 34

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

B57861S0303F040
R/T No.
T (C)
140.0
145.0
150.0
155.0

8018
B25/100 = 3964 K, R25 = 30000 , TR = 25 C, RR/RR = 1%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]
708.3
674.6
741.9
4.8
1.9
627.4
557.2
496.1

596.9
529.5
470.9

658.0
585.0
521.4

4.9
5.0
5.1

2.0
2.1
2.2

(%/K)
2.5
2.4
2.3
2.3

B57861S0303H040
R/T No.
T (C)

8018
B25/100 = 3964 K, R25 = 30000 , TR = 25 C, RR/RR = 3%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]

(%/K)

55.0
50.0
45.0
40.0
35.0

2472200
1750300
1253200
907060
663280

2276300
1618700
1163900
845770
620830

2668200
1881900
1342600
968340
705730

7.9
7.5
7.1
6.8
6.4

1.1
1.1
1.1
1.1
1.0

7.0
6.8
6.6
6.4
6.2

30.0
25.0
20.0
15.0
10.0

489810
365130
274640
208370
159410

460140
344210
259780
197730
151720

519480
386040
289510
219020
167090

6.1
5.7
5.4
5.1
4.8

1.0
1.0
1.0
0.9
0.9

6.0
5.8
5.6
5.4
5.3

5.0
0.0
5.0
10.0
15.0

122920
95501
74745
58911
46745

117340
91426
71750
56699
45103

128490
99576
77739
61122
48386

4.5
4.3
4.0
3.8
3.5

0.9
0.9
0.8
0.8
0.8

5.1
5.0
4.8
4.7
4.6

20.0
25.0
30.0
35.0
40.0

37332
30000
24253
19720
16123

36108
29100
23460
19033
15528

38555
30900
25046
20406
16717

3.3
3.0
3.3
3.5
3.7

0.7
0.7
0.8
0.9
0.9

4.4
4.3
4.2
4.1
4.0

45.0
50.0
55.0
60.0
65.0

13252
10949
9091
7584
6356

12737
10503
8703
7247
6062

13767
11396
9479
7921
6650

3.9
4.1
4.3
4.4
4.6

1.0
1.1
1.2
1.2
1.3

3.9
3.8
3.7
3.6
3.5

70.0
75.0
80.0
85.0
90.0

5351
4524
3840
3273
2800

5094
4299
3643
3100
2648

5607
4748
4037
3446
2952

4.8
5.0
5.1
5.3
5.4

1.4
1.5
1.6
1.7
1.8

3.4
3.3
3.2
3.2
3.1

Please read Important notes and


Cautions and warnings at the end of this document.

Page 22 of 34

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

B57861S0303H040
R/T No.
T (C)
95.0
100.0
105.0
110.0
115.0

8018
B25/100 = 3964 K, R25 = 30000 , TR = 25 C, RR/RR = 3%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]
5.6
1.9
2539
2405
2271
5.7
1.9
2191
2073
1954
5.9
2.0
1897
1792
1687
6.0
2.1
1649
1555
1462
6.1
2.2
1437
1354
1271

(%/K)
3.0
2.9
2.9
2.8
2.7

120.0
125.0
130.0
135.0
140.0

1182
1036
910.0
801.7
708.3

1108
969.6
850.7
748.5
660.5

1257
1102
969.2
854.9
756.1

6.3
6.4
6.5
6.6
6.8

2.3
2.4
2.5
2.6
2.8

2.7
2.6
2.6
2.5
2.5

145.0
150.0
155.0

627.4
557.2
496.1

584.4
518.4
461.0

670.5
596.1
531.3

6.9
7.0
7.1

2.9
3.0
3.1

2.4
2.3
2.3

B57861S0303J040
R/T No.
T (C)

8018
B25/100 = 3964 K, R25 = 30000 , TR = 25 C, RR/RR = 5%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]

(%/K)

55.0
50.0
45.0
40.0
35.0

2472200
1750300
1253200
907060
663280

2226900
1583700
1138800
827630
607570

2717600
1916900
1367700
986480
718990

9.9
9.5
9.1
8.8
8.4

1.4
1.4
1.4
1.4
1.4

7.0
6.8
6.6
6.4
6.2

30.0
25.0
20.0
15.0
10.0

489810
365130
274640
208370
159410

450340
336910
254280
193560
148540

529280
393350
295000
223190
170270

8.1
7.7
7.4
7.1
6.8

1.4
1.3
1.3
1.3
1.3

6.0
5.8
5.6
5.4
5.3

5.0
0.0
5.0
10.0
15.0

122920
95501
74745
58911
46745

114880
89516
70255
55521
44168

130950
101490
79234
62301
49321

6.5
6.3
6.0
5.8
5.5

1.3
1.3
1.2
1.2
1.2

5.1
5.0
4.8
4.7
4.6

20.0
25.0
30.0
35.0
40.0

37332
30000
24253
19720
16123

35362
28500
22975
18639
15206

39302
31500
25531
20801
17040

5.3
5.0
5.3
5.5
5.7

1.2
1.2
1.3
1.3
1.4

4.4
4.3
4.2
4.1
4.0

45.0

13252

12472

14032

5.9

1.5

3.9

Please read Important notes and


Cautions and warnings at the end of this document.

Page 23 of 34

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

B57861S0303J040
R/T No.
T (C)
50.0
55.0
60.0
65.0

8018
B25/100 = 3964 K, R25 = 30000 , TR = 25 C, RR/RR = 5%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]
6.1
1.6
11615
10949
10284
6.3
1.7
9660
9091
8521
6.4
1.8
8073
7584
7095
6.6
1.9
6777
6356
5935

(%/K)
3.8
3.7
3.6
3.5

70.0
75.0
80.0
85.0
90.0

5351
4524
3840
3273
2800

4987
4209
3567
3035
2592

5714
4838
4114
3511
3008

6.8
7.0
7.1
7.3
7.4

2.0
2.1
2.2
2.3
2.4

3.4
3.3
3.2
3.2
3.1

95.0
100.0
105.0
110.0
115.0

2405
2073
1792
1555
1354

2223
1912
1651
1431
1244

2587
2233
1933
1680
1464

7.6
7.7
7.9
8.0
8.1

2.5
2.6
2.7
2.9
3.0

3.0
2.9
2.9
2.8
2.7

120.0
125.0
130.0
135.0
140.0

1182
1036
910.0
801.7
708.3

1085
948.9
832.5
732.5
646.3

1280
1123
987.4
870.9
770.3

8.3
8.4
8.5
8.6
8.8

3.1
3.2
3.3
3.4
3.6

2.7
2.6
2.6
2.5
2.5

145.0
150.0
155.0

627.4
557.2
496.1

571.8
507.2
451.1

683.1
607.3
541.2

8.9
9.0
9.1

3.7
3.8
4.0

2.4
2.3
2.3

B57861S0503F040
R/T No.
T (C)

2901
B25/100 = 3760 K, R25 = 50000 , TR = 25 C, RR/RR = 1%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]

(%/K)

55.0
50.0
45.0
40.0
35.0

3198400
2308900
1686900
1246300
930550

3016900
2186800
1603900
1189400
891210

3379900
2431000
1769900
1303200
969890

5.7
5.3
4.9
4.6
4.2

0.9
0.8
0.8
0.8
0.7

6.4
6.3
6.1
6.0
5.8

30.0
25.0
20.0
15.0
10.0

701670
533960
409900
315620
245070

674280
514780
396410
306130
238390

729050
553130
423390
325100
251750

3.9
3.6
3.3
3.0
2.7

0.7
0.7
0.6
0.6
0.5

5.6
5.5
5.3
5.1
5.0

5.0
0.0

191050
150140

186350
146830

195750
153450

2.5
2.2

0.5
0.5

4.9
4.7

Please read Important notes and


Cautions and warnings at the end of this document.

Page 24 of 34

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

B57861S0503F040
R/T No.
T (C)
5.0
10.0
15.0

2901
B25/100 = 3760 K, R25 = 50000 , TR = 25 C, RR/RR = 1%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]
2.0
0.4
121340
119010
116680
1.7
0.4
96630
94998
93366
1.5
0.3
77418
76284
75149

(%/K)
4.6
4.5
4.3

20.0
25.0
30.0
35.0
40.0

61651
50000
40839
33583
27764

60871
49500
40326
33093
27304

62431
50500
41353
34073
28223

1.3
1.0
1.3
1.5
1.7

0.3
0.2
0.3
0.4
0.4

4.2
4.1
4.0
3.9
3.8

45.0
50.0
55.0
60.0
65.0

23048
19229
16092
13534
11453

22623
18840
15737
13213
11162

23472
19619
16446
13856
11745

1.8
2.0
2.2
2.4
2.5

0.5
0.6
0.6
0.7
0.8

3.7
3.6
3.5
3.4
3.3

70.0
75.0
80.0
85.0
90.0

9734
8304
7111
6109
5267

9471
8066
6896
5916
5092

9997
8541
7325
6302
5441

2.7
2.9
3.0
3.2
3.3

0.8
0.9
1.0
1.1
1.1

3.2
3.2
3.1
3.0
2.9

95.0
100.0
105.0
110.0
115.0

4562
3964
3453
3017
2644

4404
3822
3325
2901
2539

4719
4106
3582
3133
2749

3.4
3.6
3.7
3.8
4.0

1.2
1.3
1.4
1.4
1.5

2.9
2.8
2.7
2.7
2.6

120.0
125.0
130.0
135.0
140.0

2324
2049
1812
1605
1425

2229
1963
1733
1534
1360

2419
2136
1890
1676
1490

4.1
4.2
4.3
4.4
4.6

1.6
1.7
1.8
1.9
1.9

2.6
2.5
2.4
2.4
2.3

145.0
150.0
155.0

1269
1132
1012

1209
1078
962.2

1328
1186
1061

4.7
4.8
4.9

2.0
2.1
2.2

2.3
2.3
2.2

B57861S0503H040
R/T No.
T (C)
55.0
50.0
45.0

2901
B25/100 = 3760 K, R25 = 50000 , TR = 25 C, RR/RR = 3%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]
3198400
2308900
1686900

2953000
2140600
1570200

Please read Important notes and


Cautions and warnings at the end of this document.

3443900
2477200
1803600

7.7
7.3
6.9

Page 25 of 34

1.2
1.2
1.1

(%/K)
6.4
6.3
6.1

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

B57861S0503H040
R/T No.
T (C)
40.0
35.0

2901
B25/100 = 3760 K, R25 = 50000 , TR = 25 C, RR/RR = 3%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]
6.6
1.1
1328200
1246300
1164500
6.2
1.1
988500
930550
872600

(%/K)
6.0
5.8

30.0
25.0
20.0
15.0
10.0

701670
533960
409900
315620
245070

660250
504110
388210
299820
233480

743080
563810
431590
331410
256650

5.9
5.6
5.3
5.0
4.7

1.1
1.0
1.0
1.0
0.9

5.6
5.5
5.3
5.1
5.0

5.0
0.0
5.0
10.0
15.0

191050
150140
119010
94998
76284

182530
143820
114300
91466
73623

199570
156450
123720
98530
78944

4.5
4.2
4.0
3.7
3.5

0.9
0.9
0.9
0.8
0.8

4.9
4.7
4.6
4.5
4.3

20.0
25.0
30.0
35.0
40.0

61651
50000
40839
33583
27764

59638
48500
39509
32421
26749

63664
51500
42170
34745
28778

3.3
3.0
3.3
3.5
3.7

0.8
0.7
0.8
0.9
1.0

4.2
4.1
4.0
3.9
3.8

45.0
50.0
55.0
60.0
65.0

23048
19229
16092
13534
11453

22162
18455
15416
12942
10933

23933
20003
16768
14126
11974

3.8
4.0
4.2
4.4
4.5

1.0
1.1
1.2
1.3
1.4

3.7
3.6
3.5
3.4
3.3

70.0
75.0
80.0
85.0
90.0

9734
8304
7111
6109
5267

9276
7900
6754
5793
4987

10192
8707
7467
6424
5546

4.7
4.9
5.0
5.2
5.3

1.5
1.5
1.6
1.7
1.8

3.2
3.2
3.1
3.0
2.9

95.0
100.0
105.0
110.0
115.0

4562
3964
3453
3017
2644

4313
3743
3256
2841
2486

4810
4186
3651
3193
2802

5.4
5.6
5.7
5.8
6.0

1.9
2.0
2.1
2.2
2.3

2.9
2.8
2.7
2.7
2.6

120.0
125.0
130.0
135.0
140.0

2324
2049
1812
1605
1425

2182
1922
1697
1502
1332

2466
2177
1926
1709
1519

6.1
6.2
6.3
6.4
6.6

2.4
2.5
2.6
2.7
2.8

2.6
2.5
2.4
2.4
2.3

145.0
150.0
155.0

1269
1132
1012

1184
1055
942.0

1353
1208
1081

6.7
6.8
6.9

2.9
3.0
3.1

2.3
2.3
2.2

Please read Important notes and


Cautions and warnings at the end of this document.

Page 26 of 34

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

B57861S0503J040
R/T No.
T (C)

2901
B25/100 = 3760 K, R25 = 50000 , TR = 25 C, RR/RR = 5%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]

(%/K)

55.0
50.0
45.0
40.0
35.0

3198400
2308900
1686900
1246300
930550

2889000
2094500
1536400
1139600
853990

3507900
2523400
1837300
1353100
1007100

9.7
9.3
8.9
8.6
8.2

1.5
1.5
1.5
1.4
1.4

6.4
6.3
6.1
6.0
5.8

30.0
25.0
20.0
15.0
10.0

701670
533960
409900
315620
245070

646220
493430
380010
293510
228580

757120
574490
439790
337720
261560

7.9
7.6
7.3
7.0
6.7

1.4
1.4
1.4
1.4
1.3

5.6
5.5
5.3
5.1
5.0

5.0
0.0
5.0
10.0
15.0

191050
150140
119010
94998
76284

178710
140820
111920
89566
72097

203390
159450
126100
100430
80470

6.5
6.2
6.0
5.7
5.5

1.3
1.3
1.3
1.3
1.3

4.9
4.7
4.6
4.5
4.3

20.0
25.0
30.0
35.0
40.0

61651
50000
40839
33583
27764

58405
47500
38692
31750
26194

64897
52500
42987
35417
29333

5.3
5.0
5.3
5.5
5.7

1.3
1.2
1.3
1.4
1.5

4.2
4.1
4.0
3.9
3.8

45.0
50.0
55.0
60.0
65.0

23048
19229
16092
13534
11453

21701
18071
15094
12671
10704

24394
20388
17090
14397
12203

5.8
6.0
6.2
6.4
6.5

1.6
1.7
1.8
1.9
2.0

3.7
3.6
3.5
3.4
3.3

70.0
75.0
80.0
85.0
90.0

9734
8304
7111
6109
5267

9082
7734
6612
5671
4882

10387
8873
7609
6546
5651

6.7
6.9
7.0
7.2
7.3

2.1
2.2
2.3
2.4
2.5

3.2
3.2
3.1
3.0
2.9

95.0
100.0
105.0
110.0
115.0

4562
3964
3453
3017
2644

4222
3664
3187
2780
2433

4901
4265
3720
3254
2855

7.4
7.6
7.7
7.8
8.0

2.6
2.7
2.8
2.9
3.0

2.9
2.8
2.7
2.7
2.6

120.0
125.0
130.0
135.0

2324
2049
1812
1605

2136
1881
1661
1469

2512
2218
1963
1741

8.1
8.2
8.3
8.4

3.2
3.3
3.4
3.5

2.6
2.5
2.4
2.4

Please read Important notes and


Cautions and warnings at the end of this document.

Page 27 of 34

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

B57861S0503J040
R/T No.
T (C)
140.0
145.0
150.0
155.0

2901
B25/100 = 3760 K, R25 = 50000 , TR = 25 C, RR/RR = 5%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]
8.6
3.6
1548
1425
1303
1269
1132
1012

1159
1032
921.7

1379
1231
1101

8.7
8.8
8.9

3.8
3.9
4.0

(%/K)
2.3
2.3
2.3
2.2

B57861S0104F040
R/T No.
T (C)

2014
B25/100 = 4540 K, R25 = 100000 , TR = 25 C, RR/RR = 1%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]

(%/K)

55.0
50.0
45.0
40.0
35.0

14200000
9661500
6656200
4640000
3270800

13258000
9065600
6275300
4394300
3111000

15142000
10257000
7037000
4885700
3430600

6.6
6.2
5.7
5.3
4.9

0.8
0.8
0.8
0.7
0.7

7.8
7.6
7.3
7.1
6.9

30.0
25.0
20.0
15.0
10.0

2330200
1677000
1218600
893700
661250

2225500
1607900
1172800
863230
640920

2435000
1746100
1264400
924170
681590

4.5
4.1
3.8
3.4
3.1

0.7
0.6
0.6
0.6
0.5

6.7
6.5
6.3
6.1
5.9

5.0
0.0
5.0
10.0
15.0

493420
371200
281450
215000
165440

479840
362130
275410
211010
162830

507010
380270
287480
219000
168050

2.8
2.4
2.1
1.9
1.6

0.5
0.4
0.4
0.3
0.3

5.8
5.6
5.5
5.3
5.2

20.0
25.0
30.0
35.0
40.0

128190
100000
78514
62031
49304

126510
99000
77493
61073
48427

129870
101000
79536
62989
50181

1.3
1.0
1.3
1.5
1.8

0.3
0.2
0.3
0.3
0.4

5.0
4.9
4.8
4.7
4.5

45.0
50.0
55.0
60.0
65.0

39417
31690
25616
20815
17000

38626
30984
24990
20263
16515

40208
32396
26242
21367
17484

2.0
2.2
2.4
2.6
2.9

0.5
0.5
0.6
0.6
0.7

4.4
4.3
4.2
4.1
4.0

70.0
75.0
80.0
85.0
90.0

13952
11505
9530
7930
6626

13527
11132
9204
7644
6376

14377
11877
9856
8215
6876

3.0
3.2
3.4
3.6
3.8

0.8
0.8
0.9
1.0
1.1

3.9
3.8
3.7
3.6
3.5

Please read Important notes and


Cautions and warnings at the end of this document.

Page 28 of 34

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

B57861S0104F040
R/T No.
T (C)
95.0
100.0
105.0
110.0
115.0

2014
B25/100 = 4540 K, R25 = 100000 , TR = 25 C, RR/RR = 1%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]
3.9
1.1
5779
5560
5341
4.1
1.2
4877
4684
4492
4.3
1.3
4131
3962
3793
4.4
1.4
3512
3363
3214
4.6
1.4
2997
2866
2735

(%/K)
3.5
3.4
3.3
3.2
3.2

120.0
125.0
130.0
135.0
140.0

2451
2103
1810
1563
1354

2335
2000
1719
1483
1283

2566
2205
1901
1644
1426

4.7
4.9
5.0
5.2
5.3

1.5
1.6
1.7
1.8
1.9

3.1
3.0
3.0
2.9
2.8

145.0
150.0
155.0

1177
1026
896.6

1113
968.9
845.7

1241
1083
947.5

5.4
5.5
5.7

2.0
2.0
2.1

2.8
2.7
2.7

B57861S0104H040
R/T No.
T (C)

2014
B25/100 = 4540 K, R25 = 100000 , TR = 25 C, RR/RR = 3%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]

(%/K)

55.0
50.0
45.0
40.0
35.0

14200000
9661500
6656200
4640000
3270800

12974000
8872400
6142200
4301500
3045600

15426000
10451000
7170200
4978500
3496000

8.6
8.2
7.7
7.3
6.9

1.1
1.1
1.1
1.0
1.0

7.8
7.6
7.3
7.1
6.9

30.0
25.0
20.0
15.0
10.0

2330200
1677000
1218600
893700
661250

2178900
1574400
1148400
845360
627690

2481600
1779600
1288700
942050
694810

6.5
6.1
5.8
5.4
5.1

1.0
0.9
0.9
0.9
0.9

6.7
6.5
6.3
6.1
5.9

5.0
0.0
5.0
10.0
15.0

493420
371200
281450
215000
165440

469970
354710
269780
206710
159520

516880
387700
293110
223300
171360

4.8
4.4
4.1
3.9
3.6

0.8
0.8
0.8
0.7
0.7

5.8
5.6
5.5
5.3
5.2

20.0
25.0
30.0
35.0
40.0

128190
100000
78514
62031
49304

123950
97000
75922
59832
47441

132440
103000
81106
64229
51168

3.3
3.0
3.3
3.5
3.8

0.7
0.6
0.7
0.8
0.8

5.0
4.9
4.8
4.7
4.5

45.0

39417

37837

40996

4.0

0.9

4.4

Please read Important notes and


Cautions and warnings at the end of this document.

Page 29 of 34

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

B57861S0104H040
R/T No.
T (C)
50.0
55.0
60.0
65.0

2014
B25/100 = 4540 K, R25 = 100000 , TR = 25 C, RR/RR = 3%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]
4.2
1.0
33030
31690
30350
4.4
1.1
26754
25616
24478
4.6
1.1
21783
20815
19847
4.9
1.2
17824
17000
16175

(%/K)
4.3
4.2
4.1
4.0

70.0
75.0
80.0
85.0
90.0

13952
11505
9530
7930
6626

13248
10902
9013
7486
6244

14656
12107
10047
8374
7009

5.0
5.2
5.4
5.6
5.8

1.3
1.4
1.5
1.5
1.6

3.9
3.8
3.7
3.6
3.5

95.0
100.0
105.0
110.0
115.0

5560
4684
3962
3363
2866

5230
4398
3713
3147
2677

5891
4971
4210
3580
3054

5.9
6.1
6.3
6.4
6.6

1.7
1.8
1.9
2.0
2.1

3.5
3.4
3.3
3.2
3.2

120.0
125.0
130.0
135.0
140.0

2451
2103
1810
1563
1354

2286
1958
1683
1451
1256

2615
2247
1937
1675
1453

6.7
6.9
7.0
7.2
7.3

2.2
2.3
2.4
2.5
2.6

3.1
3.0
3.0
2.9
2.8

145.0
150.0
155.0

1177
1026
896.6

1090
948.4
827.8

1264
1103
965.4

7.4
7.5
7.7

2.7
2.8
2.9

2.8
2.7
2.7

B57861S0104J040
R/T No.
T (C)

2014
B25/100 = 4540 K, R25 = 100000 , TR = 25 C, RR/RR = 5%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]

(%/K)

55.0
50.0
45.0
40.0
35.0

14200000
9661500
6656200
4640000
3270800

12690000
8679100
6009100
4208700
2980100

15710000
10644000
7303300
5071300
3561500

10.6
10.2
9.7
9.3
8.9

1.4
1.3
1.3
1.3
1.3

7.8
7.6
7.3
7.1
6.9

30.0
25.0
20.0
15.0
10.0

2330200
1677000
1218600
893700
661250

2132300
1540900
1124100
827490
614470

2528200
1813100
1313100
959920
708040

8.5
8.1
7.8
7.4
7.1

1.3
1.3
1.2
1.2
1.2

6.7
6.5
6.3
6.1
5.9

5.0
0.0

493420
371200

460100
347280

526750
395120

6.8
6.4

1.2
1.1

5.8
5.6

Please read Important notes and


Cautions and warnings at the end of this document.

Page 30 of 34

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

B57861S0104J040
R/T No.
T (C)
5.0
10.0
15.0

2014
B25/100 = 4540 K, R25 = 100000 , TR = 25 C, RR/RR = 5%
Rnom[]
Rmin[]
Rmax[]
RR/RR[%] T[C]
6.1
1.1
298740
281450
264150
5.9
1.1
227600
215000
202410
5.6
1.1
174670
165440
156210

(%/K)
5.5
5.3
5.2

20.0
25.0
30.0
35.0
40.0

128190
100000
78514
62031
49304

121390
95000
74352
58592
46455

135000
105000
82676
65470
52154

5.3
5.0
5.3
5.5
5.8

1.1
1.0
1.1
1.2
1.3

5.0
4.9
4.8
4.7
4.5

45.0
50.0
55.0
60.0
65.0

39417
31690
25616
20815
17000

37049
29716
23966
19431
15835

41785
33663
27266
22199
18164

6.0
6.2
6.4
6.6
6.9

1.4
1.4
1.5
1.6
1.7

4.4
4.3
4.2
4.1
4.0

70.0
75.0
80.0
85.0
90.0

13952
11505
9530
7930
6626

12969
10672
8823
7327
6111

14935
12337
10237
8532
7141

7.0
7.2
7.4
7.6
7.8

1.8
1.9
2.0
2.1
2.2

3.9
3.8
3.7
3.6
3.5

95.0
100.0
105.0
110.0
115.0

5560
4684
3962
3363
2866

5118
4304
3634
3080
2620

6002
5064
4289
3647
3112

7.9
8.1
8.3
8.4
8.6

2.3
2.4
2.5
2.6
2.7

3.5
3.4
3.3
3.2
3.2

120.0
125.0
130.0
135.0
140.0

2451
2103
1810
1563
1354

2237
1916
1647
1420
1229

2664
2289
1973
1706
1480

8.7
8.9
9.0
9.2
9.3

2.8
2.9
3.0
3.2
3.3

3.1
3.0
3.0
2.9
2.8

145.0
150.0
155.0

1177
1026
896.6

1066
927.8
809.9

1288
1124
983.3

9.4
9.5
9.7

3.4
3.5
3.6

2.8
2.7
2.7

Please read Important notes and


Cautions and warnings at the end of this document.

Page 31 of 34

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

Cautions and warnings


General
See "Important notes" at the end of this document.
Storage
Store thermistors only in original packaging. Do not open the package before storage.
Storage conditions in original packaging: storage temperature 25 C ... +45 C, relative
humidity 75% annual mean, maximum 95%, dew precipitation is inadmissible.
Do not store SMDs where they are exposed to heat or direct sunlight. Otherwise, the packing
material may be deformed or SMDs may stick together, causing problems during mounting.
Avoid contamination of thermistors surface during storage, handling and processing.
Avoid storage of thermistor in harmful environments like corrosive gases (SOx, Cl etc).
After opening the factory seals, such as polyvinyl-sealed packages, use the SMDs as soon as
possible.
Solder thermistors after shipment from EPCOS within the time specified:
SMDs: 12 months
Leaded components: 24 months
Handling
NTC thermistors must not be dropped. Chip-offs must not be caused during handling of NTCs.
Components must not be touched with bare hands. Gloves are recommended.
Avoid contamination of thermistor surface during handling.
Soldering
Use resin-type flux or non-activated flux.
Insufficient preheating may cause ceramic cracks.
Rapid cooling by dipping in solvent is not recommended.
Complete removal of flux is recommended.
Mounting
When NTC thermistors are encapsulated with sealing material or overmolded with plastic
material, the precautions given in chapter Mounting instructions, Sealing, potting and
overmolding must be observed.
Electrode must not be scratched before/during/after the mounting process.
Contacts and housings used for assembly with thermistor have to be clean before mounting.
During operation, the thermistors surface temperature can be very high (ICL). Ensure that
adjacent components are placed at a sufficient distance from the thermistor to allow for proper
cooling ot the thermistors.
Ensure that adjacent materials are designed for operation at temperatures comparable to the
surface temperature of the thermistor. Be sure that surrounding parts and materials can
withstand this temperature.
Make sure that thermistors (ICLs) are adequately ventilated to avoid overheating.
Avoid contamination of thermistor surface during processing.
Please read Important notes and
Cautions and warnings at the end of this document.

Page 32 of 34

Temperature measurement

B57861

Miniature sensors with bendable wires

S861

Operation
Use thermistors only within the specified operating temperature range.
Use thermistors only within the specified voltage and current ranges (ICLs).
Environmental conditions must not harm the thermistors. Use thermistors only in normal
atmospheric conditions.
Contact of NTC thermistors with any liquids and solvents should be prevented. It must be
ensured that no water enters the NTC thermistor (e.g. through plug terminals). For
measurement purposes (checking the specified resistance vs. temperature), the component
must not be immersed in water but in suitable liquids (e.g. Galden).
Avoid dewing and condensation.
Be sure to provide an appropriate fail-safe function to prevent secondary product damage
caused by malfunction (e.g. use VDR for limitation of overvoltage condition).

Please read Important notes and


Cautions and warnings at the end of this document.

Page 33 of 34

Important notes

The following applies to all products named in this publication:


1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application.
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar
with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of passive electronic components or failure before the end of their usual service life cannot be completely ruled out
in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications
in which the malfunction or failure of a passive electronic component could endanger human
life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured
by means of suitable design of the customer application or other action taken by the customer
(e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by
third parties in the event of malfunction or failure of a passive electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous). Useful information on this will be found in our
Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more
detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order.
We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be
available.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the General Terms of Delivery for Products and Services in the Electrical Industry published by the German Electrical and Electronics Industry Association
(ZVEI).
7. The trade names EPCOS, EPCOS-JONES, Baoke, CeraDiode, CSSP, MLSC, PhaseCap,
PhaseMod, SIFI, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, UltraCap, WindCap are
trademarks registered or pending in Europe and in other countries. Further information will
be found on the Internet at www.epcos.com/trademarks.

Page 34 of 34

You might also like