You are on page 1of 6

QUI TRNH TH LC KO BCH TU DCH V

I. CHUN B 1. Thit b o Thit b Load cell ca Cng ty Elion Engineering, sn xut nm 2006, c cc thng s sau: STT 1 2 3 4 5 Catalog No. 2501-S-200 DL Clock RS-232 Cable M t RON 2501 S 200T cap dynamiometer Data logger with 3000 load value memory Real time clock RS-232 Interface cable Standard Thng s k thut 200 tn 3000 point

Test report km theo.

2. a im th: a im th c chn l Cng Ci mp (Cng ty c phn du kh Vng tu). Khu vc th c ng knh 300m, su trn 20m. Bch th t trn b c lc ko ngang cc i 120 tn. 3. S b tr 6 1 111 2 3a
3b

SHORE

300M

(1) Ma-n 150 tn, ni vo bch (2) Cp thp D = mm (150 tn)

(3) Ma-n 150 tn (4) Load-cell 200 tn ( 5 ) Cp tu (t ti cng ngh (6))

II. QUI TRNH TH: 1. Chun b cp, ma-n, load-cell, lp rp theo s th trn. 2. Tu iu ng cch b 10m, tu lai ko cp tu vo b, dng xe cu ko cp tu vo v tr ni vi man (3b). 3. Th t t cp ti, iu ng tu ra khu vc th (cch b 300m). 4. Neo tu vo v tr th, ko ti cho cp cng va , b cht phanh ti. 5. Khi ng v gia tc my theo qui trnh k thut n tc nh mc, tng ti bng cch tng bc chn vt theo tun t sau: - 55% - 1 pht. - 60% - 1 pht. - 70% - 1 pht. - 80% - 3 pht. - 85% - 5 pht. - 90% - 2 pht - 85% - 10 pht. - Gim ti t t v zero. - Tho cp tu, dng ti thu cp, kt thc qu trnh th. III. CC YU CU KHI TH 1. Trong sut qu trnh th ko lin tc vi lc ko khng i BPconst , my chnh s chy tc lin tc cc i theo (NSX). 2. Trong sut qu trnh th lc ko qu ti, my chnh s chy vi tc cc i v duy tr t nht 1 gi. Vic th qu ti ny khng bt buc (c th b qua). 3. Khi th phi tin hnh vi cc chn vt lm vic khi tu hot ng. 4. Tt c cc thit b ph nh bm, my pht, c lai bi my chnh hoc trc chn vt trong iu kin lm vic bnh thng ca tu s c a vo trong qu trnh th. 5. Chiu di ca dy ti t nht l 300m, o gia ui tu v b. 6. su khu vc th t nht l 20m trong vng bn knh 100m quanh tu. 7. Vic th c thc hin khi tu y nc dn (full ballast) v cc kt nhin liu cn mt na (haft fuel capacity). 8. Vic th thc hin khi tu cn bng hoc chi li khng qu 2% chiu di tu. 9. Tu s c duy tr hng khng i trong qu trnh th. 10. Khi th tc gi khng c vt qu 5m/s. 11. Dng chy khu vc th khng vt qu 1 l mi hng. 12. Load cell s dng th c chng ch ng kim (VIRES hoc cc nc) v c cn chnh t nht 1 ln trong nm (load cell mi th c php s dng 3 nm mi a i cn chnh). chnh xc ca load cell trong vng 2% trong thang nhit -100C n 400C trong vng 25 n 200 tn. 13. Thit b ch th phi c kh nng ch th lin tc v ghi li d liu trong qu trnh th c th biu din ha quan h gia lc ko theo thi gian th. 14. Load cell c gn gia dy ti v cc bch. 15. Hnh v xc nhn lc ko bch lin tc c ghi li trong mt chu trnh ti thiu 10 pht. (T) 16. Vic xc nhn lc ko bch ghi li khi my chy trng thi qu ti, gim tc hoc bc chn vt sau ghi ch trn chng ch. 17. H thng thng tin lien lc s c thit lp gia tu v b (ngi c load cell) bng VHF hoc in thoi trong sut qu trnh th.

18. Qu trnh th s c gim st bi VIRES v kt qu th s c VIRES xc nhn v cp chng ch.

( ngh ch tu cung c p cc thng s

Form sau, n dng g ch ngang) (FORM)

CERTIFICATE OF BOLLARD PULL


Name: Signal letters: Owners: M/S AN BANG __________ PTSC MARINE _______________ Type: SUPPLY VESSEL/TUG GRT: __________ Register: VIRES Length: ________

Number of Engines, Make & type Number of Propeller, Make & type Number of Nozzles, Make & type Number of Rudders, Make & type Total BHP

_______________

_______________

_______________

_______________

Max. continuous RPM: ______________

Test location: THI VAI RIVER, CAI MEP AREA Test date: 15/10/2007 Water depth at test site about 20 metres VIRES after having surveyed and examined the relevant data according to our recommendations for the testing of bollard pull, hereby declare that the above named vessel and its towing gear have been giving these results: CONTINUOUS BOLLARD PULL: BOLLARD PULL AT % OVERLOAD: Metric tons Metric tons

N.A.

TEST DATA Vessel heading: Length of towing wire: Draught: _______ ______ _____ m over stern ________

Max. allowed draught (load line): Ballast onboard: Fuel onboard: ______ ______ Total capacity: Total capacity: ______ ______

Stores. Freshwater, Lub. Oil: Wind direction: Current setting: Air temp.: ______ ______ ______ Force: Speed: Sea water temp.: ______ ______ ______

CONTINUOUS BOLLARD PULL: BPmax = _____ tonnes BPi = _____ tonnes t= BPcont = _____ tonnes T = _____ min

BOLLARD PULL AT BPmax = _____ tonnes BPi = _____ tonnes t=

% OVERLOAD:

N.A.

Metric tons

BPoverload = _____ tonnes T = _____ min

REMARKS:

READING P R.P.M S PITCH PULL (TON)

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

You might also like