You are on page 1of 6

MPPES

Proportional Valves

420 (mA) 010 (V DC)


012 (bar)
010 (bar) 06 (bar) , 02 (bar)

-M-P-L-

G1/2, G1/4, G1/8

230 8500 l/min


18 30 V DC
0 2 bar
0 6 bar
0 10 bar

General technical data


Pneumatic connection

Design

G8

Electrical
Via through-hole

Actuation type
Type of mounting
Mounting position

Pressurisation [mm]
[mm]

Standard nominal flow rate

[l/min]

Product weight

[g]

Operating and environmental conditions


Pressure regulation range [bar]

[bar]

Max. hysteresis

[mbar]

Ambient temperature

[C]

Temperature of medium

[C]

Corrosion resistance class CRC [CRC]

Directly actuated piston Pilot-actuated piston regulator



regulator

Soft

Sealing principle

Input pressure1

. 2

Operating medium

%0.5 40

Exhaust

Pressure Sensor

Proportional Pressure Regulator/ Type: MPPES


Directly Actuated Valve or Pilot Actuated
with Proportional Solenoid

Nominal size

Any

11

12


915


1,310

02

06

2,670


0 10

Filtered compressed air, lubricated or unlubricated


-
Neutral gases

34

78

11 12

10

50

50

050

060
2

Proportional Valves

VPPM
010 06 , 02 (bar)

1/8 010 (bar)

-M-P-L-

380 1,400 l/min


21.6 26.4 V DC
0.02 10 bar

LCD LED
CPX/MPA Ethernet/Fieldbus
% 0.5 40
PNP/NPN

Proportional Pressure Regulator/Type : VPPM


Pilot - Actuated Valve

420 (mA) 010 (V)

. 2

General technical data


G8
Pilot actuated diaphragm regulator

Constructional design

Soft

Sealing principle

Electrical
Pilot actuated via 2/2-way valves

Actuation type
Type of control

Via through-hole, via accessories

Type of mounting
Nominal size Pressurisation [mm]

Product weight

[g]


400

Operating and environmental conditions

Operating medium
Input pressure1

[bar]

Max. hysteresis

[mbar]

FS (full scale) linearity error

[%]

FS (full scale) repetition accuracy

[%]

Temprature coefficient

[%/C]

Ambient temperature

[C]

Temperature of medium

[C]

Corrosion resistance class CRC

[CRC]

4.5

[l/min]

[bar]

[mm]

Standard nominal flow rate

Pressure regulation range

2/2

Any

Mounting position
Exhaust

0.02 2

0.06 6

0.1 10

Filtered compressed air, lubricated or unlubricated


-
Neutral gases

24

28

211

10

30

50

0.5
0.5
0.04/1
060
1050

VPWP
Proportional Valves

)Soft Stop( 5/3


CPX - CMAX CPX - CMPX
1% 5

-M-P-L-

380 1,400 l/min


24 V DC
0 10 bar

30%

Nominal size

G1/8
[mm]

Standard nominal flow rate [l/min]

G1/4

350

700

1,400

5/3-way proportional directional control valve


Piston spool with integrated pressure sensors

Valve function
Constructional design

Hard
Electric

Sealing principle
Actuation type
Reset method

5/3

Magnetic spring

Direction of flow

[g]

Preferably horizontal (display elements facing upwards)


780
1,060
780

Repetition accuracy FS

[%]

< 1

Pressure resolution

[bar]

Linearity error FS2)

[%]

Assembly position1)
Product weight

Direct
Non-reversible

Type of control

Pressure sensors

0.01
< 1.5

Operating and environmental conditions


Operating medium
Operating presure

[bar]

Nominal Operating pressure [bar]


Ambient temperature

[C]

temperature of medium

[C]

Storage temperature

[C]

Protection Class

. 2

General technical data

Nominal size

Pneumatic connection

Filtered compressed air, or unlubricated

010

050
050

IP65

-20+70

VPPE

) 7 (bar )0.156 (bar

Proportional Valves

) 010 (V DC )420 (mA

600 l/min

) 11 (bar ) 02 (bar 0.066 0.110

1250 l/min
40 %0.5

2 .

310 1,250 l/min


21.6 26.4 V DC
0.15 6 bar

-M-P-L-

General technical data


G1/8

Pilot actuated 3-way proportional regulator


Soft

Electrical
Pilot actuated via 2/2-way valves

2/2

Actuation type
Type of control

Via through-hole
Any , preferably vertical

Type of mounting
Mounting position

][mm

Air supply

2.5

][mm

Exhaust

Nominal Size

][l/min

Standard nominal flow rate

][g

Product weight

390 445

Operating and environmental conditions


0 10

Design
Sealing principle

06

0 2.5

01

][bar

Filtered, unlubricated compressed air, grade of filtration 40 m


40 Neutral gases
78

0.1550
0.15

1050

1050

Pressure regulation range


Operating medium

][bar

Supply pressure

][bar

Pressure regulation range

][bar

Max. pressure hysteresis

][C

Ambient temperature

][C

Temperature of medium

][CRC

Corrosion resistance class CRC

Proportional Valves

MPYE

-M-P-L-

100 2,000 l/min


17 30 V DC
0 10 bar

420 (mA) 010 (V DC)


G3/8, G1/4, G1/8 ,M5

Proportional Directional Control Valve / Type : MPYE


Piston Spool, Directly Actuated, Controlled Piston
Spool Position

. 2

Pneumatic connection

M5

G1/8
Low flow

Constructional design
Sealing principle
Actuation type
Type of reset
Direction of flow
Type of mounting
Mounting position1)
Operating medium
Nominal size

[mm]

Standard nominal flow rate [l/min]


Product weight

[g]

G1/4
High flow

Electrical

Mechanical spring

Direct

Non-reversible

Via through-holes

Any
Compressed air, filtered (to 5 m), unlubricated
Hard

10

350

700

1400

2000

330

330

530

740

Electrical data
Pneumatic connection

M5

Power supply
[V DC]
Max. current consumption in mid-position [mA]
Setpoint value

at full stroke

[mA]

Voltage type

[V DC]

Current type

[mA]

Max. hysteresis
Valve mid-position
Duty cycle

[%]
Voltage type

Current type

Critical frequency
Safety setting
Protection class
Electrical connection

[V DC]
[%]

G1/8

G1/4

Low flow

High flow

100

100


G3/8

17 30
100

1100

010

420
0.4

5(0.1)

[mA]
[Hz]

G3/8

5/3
5/3-way, normally closed
Piston spool, directly actuated, controlled piston spool position






2
100
290

Type of pilot control

General technical data

Valve function

12 (0.16)

100
125

90

65

Active mid-position in the event of setpoint value cable break


IP65
4-pin plug socket, round design, M12x1

MPPE

Proportional Valves

G1/2, G1/4, G1/8


011 (bar)

-M-P-L-

010 (bar) 06 (bar) , 02.5 (bar) , 01 (bar)

350 8800 l/min


18 30 V DC
0 1 bar
0 2.5 bar
0 6 bar
0 10 bar

% 0.5 40
420 (mA) 010 (VDC)

Proportional Pressure Regulator/ Type: MPPE


Pilot - Actuated with Poppet Valve

. 2

General technical data


G1/4

G1/8

G1/2

Pilot actuated diaphragm regulator


Soft

Design
Sealing principle

Electrical

Actuation type

Pilot actuated via 2/2-way valves


Via through-hole, via accessories

Type of control
Type of mounting

2/2

Any

Mounting position
Nominal diameter Pressurisation
Exhaust

[mm]

11

[mm]

12

Standard nominal flow rate

[l/min]

Product weight

[g]

710

.
920

2,400

Operating and environmental conditions


Pressure regulation range

[bar]

Operating medium
Supply pressure

[bar]

Max. pressure hysteresis

[bar]

Ambient temperature

[C]

Temperature of medium

[C]

Corrosion resistance class CRC

[CRC]


01

0 2.5

06

0 10

Filtered compressed air, lubricated or unlubricated, grade of filtration 40


m Neutral gases -
1.52
3.54.5
78
1112

30

40

40

50

050

060

021-44524408 :u 021-44522409 :U :IinI qo oTj


021-88822162:u 021-88829225 :U
:xpA qo
0411-5241809 :u 0411-5234734:U
:qoLU Tv
0311-2357148 :uU
:IH Tv
0511-8537605 :u 0511-8537604:U
:kz Tv
www.festo.ir
:SIw J
mailroom@festo.ir
:oTH SvQ

You might also like