9.

Feed rate control

One of the most important factor in the control of the feed into the kiln is the accuracy of the kiln raw meal feed weigh-feeder i.e the dosing system is reliable and working properly.

The factors which are determine the kiln feed rate are
Kiln speed Kiln cross-sectional feed loading or volumetric load Kiln cross sectional thermal loading What is the relation between kiln speed and the kiln feed rate? 1- If the feed rate changed but kiln speed is kept constant, the burning zone conditions is remains unchanged from 25 to30 minutes until the different feed rate

arrives to this zone. After a short time, the kiln inlet temperature will start to
change making it necessary to readjust the I.D. fan speed and fuel rate