You are on page 1of 95

tyco Fire & Tyco Electronic

Security Product Group


Introduction
Welcome to the Second Edition of Tyco Electronic Product Group’s Fire Product Catalogue of product available from our Letchworth
UK Distribution Centre. We aim to make your product range as comprehensive as possible to ensure you never need go anywhere
else. To meet this goal, our product specialists, with your help, have selected the most appropriate, cost effective product range all
available for next day delivery.

In line with our ISO 9000 accreditation, only those products that meet the highest quality criteria have been included.

NEW - Look out for the new products now available from the UK Letchworth warehouse including the range of newly CE marked,
UL/FM Approved, TFX range of addressable fire panels. Other new products include I.S. Barriers, Water Leak Detection equipment,
Callpoint STOPPERS and much more. A separate catalogue for Tyco MX Technology will be available shortly.

Our warehouse is one of the largest Fire & Security product distribution centres in
Europe. Our goal is to despatch product on the same day as we receive your order.
Our warranty and service returns policy is second to none. We recognise that your
business is highly dependant on excellence in customer service and to help achieve
this we offer extended warranty from many of our suppliers. Full credit is also
available on a “No Question – No Fuss” basis for any new in-warranty product
returned to the distribution centre.

Our training department offers comprehensive sales, design and engineering training on
our complete range of products. We recommend you take advantage of this free of charge
service. As always, training can be undertaken any time, anywhere to suit your business
needs. Contact our telephone Help Line for further information.

Tyco Electronic Product Group’s Web site contains an endless supply of


product related information. It is regularly updated and features many aids to
the selling process including presentation material, independent product test
results and detailed technical information.

Our web site can be found at www.tycofire.com/tycoepg

NEW - The website now includes a whole section for CAD Operators
including Standard Symbols, Drawings and Schematics for products in this
catalogue.

To enhance customer specifications and quotations we also provide a series of product


datasheets which can give our clients an opportunity to read more about the product.
We are positive that together we can help grow your business and we look forward to
working with you in the future.

For further details on this catalogue, contact our customer telephone Help Line on
+44 1932 74 3327.

NEW - Now including Product Code Index, Cross Reference to Approvals, Cross
Reference to Technical Publications and Datasheets, CAD Symbol Index and much more.

Page 1
tyco Fire & Tyco Electronic
Security Product Group
Table of Contents

3 Addressable Fire Systems - LPCB Approved


15 Addressable Fire Systems - UL/FM Approved
24 Conventional Fire Alarm Panels - BS5839 & EN54
36 Conventional Marine Panels
39 Batteries, PSU & Door Release Units
41 Addressable 900 Series Detectors
44 Conventional 600 Series Detectors
47 Standard Detector Bases
48 Functional Detector Bases
50 M600/900 Detector Ancillaries
51 Duct Probe Air Sampling
52 Aspirating Smoke
Detectors VESDA -
Visions Systems
56 Special Hazard
Detectors
59 Intrinsically Safe Point
Detectors
63 Intrinsically Safe
Barriers & Housings
65 Beam & Linear Heat
Detectors
67 Detector Test
Equipment
69 CP Series Callpoints
75 MINERVA Range of Sounders
78 Fulleon Range of Sounders
80 MINERVA Firecryer - Voice
Enhanced Sounders
81 Visual Indicators
82 Auxiliary Interface Relays/Miscellaneous Fire
Equipment
84 Water Leak Detection Alarms
85 Wire Free Product Range
89 Approvals Listing of Company Equipment

Page 2
tyco Fire & Tyco Electronic
Security Product Group
Addressable Fire Systems - LPCB Approved
ThornGraph
reduces configuration time, increases the integrity ThornNet will support up to a maximum of 3
of information and enables simple updates to the ThornGraph user interfaces on the network.
system in the future. ThornGraph consists of a standard personal
Features computer, that is linked onto the ThornNet via a
TLK-530 network interface module. ThornGraph is
• Combined text and graphics display on a single
primarily operated by either mouse or touch
P.C.
screen, with three monitor options available 17",
• Connected to ThornNet, a single system can
20" or 21" touch screen.
be used to monitor up to 62 MINERVA fire
controllers. For an up to date specification of the latest
• Designed for touch screen operation approved PC platform contact the Fire Product
• Simple operator controls, no Qwerty keypad Manager.
• High resolution colour SVGA display Product Codes
• Windows NT TM multi-tasking operating system 508.020.001
• Four level automatic zoom sequence available
Introduction Compatibility tested PC for ThornGraph graphics
for each point
terminal preloaded and configured with default
ThornGraph is a combined text and graphics • Overview map maintains a view of wider areas
passwords
system which provides a window through which whilst zooming into detail in the graphics
the status of all MINERVA fire controllers window 508.020.006
connected to ThornNet can be monitored and • Procedure window provides additional text and Thorngraph 22” touchscreen - Liyama touch pro
controlled. operator instructions for each event 510 complete with 5 year warranty
ThornGraph has been designed with clear displays • Classification of events helps to maintain a 508.020.003
and simple controls which can be quickly and record of activation and the causes
ThornGraph 17 inch standard monitor
easily understood by an operator rather than an • Browse icons placed on maps can be used to
pan across an installation in a logical sequence 508.020.004
engineer. The system is designed to be used with
a touch screen or mouse and does not require the • Control icons placed on maps can be used to ThornGraph 20 inch standard monitor
use of a Qwerty keyboard. P.C. based ThornGraph initiate actions at the MINERVA fire controller, 508.020.101
uses the latest in operating system software. used to operate ancillaries such as HVAC. Software package A for 1 network node
Windows NT TM is a multi-tasking operating system • Automatic configuration using the GRAB-IT
tool, including Cad drawings, text messages, 508.020.102
providing a truly reliable platform for a real time
monitoring system using a P.C. Using the secure locations, flood fills and zoom areas Software package B for 2-5 network node 5
acknowledged transfer of events, up to three • Full password protection and multiple operator 508.020.103
ThornGraph systems can be used to monitor up to levels Software package C for 6 or more network nodes
62 MINERVA controllers connected to ThornNet. • Remote control of MINERVA fire controller
across the network using VFP, Virtual Front 508.020.104
ThornGraph uses a unique configuration tool
Panel Software package D for additional graphics nodes
GRAB-IT, (Graphical, AutoCad, Bitmap,
• Real time on line event management and on the same ThornNet
Information, Transfer) to automatically configure
the system. Installation plans, device type and historic information system
location, flood fill areas, flood fill locations, zoom • User designed search keys can be used to Datasheet - Product Code PSF80 “Thorngraph”
areas and zoom magnifications are all imported generate specific and useful reports
Manual - Vol011B “Software Operating Manual”
from AutoCad. This configuration tool significantly ThornGraph provides a graphical user interface to
the ThornNet, network communications system.
ThornGraph Typical Arrangement

Page 3
tyco Fire & Tyco Electronic
Security Product Group
ThornNet
ThornNet provides a true peer to peer processing of other panels to co-ordinate and single "seamless" system.
communications interface for up to 62, MINERVA distribute systems control. • ThornGraph, a P.C. based graphical user
8, MINERVA 16E or MINERVA 80 fire controllers • System can be configured in the field using interface, connects directly on to the network.
in any combination and the ThornGraph, graphical Consys software. • ThornNet supports combinations of MICC,
user interface. The units can be inter-connected
• Failure of one node does not affect any other twisted/shielded pair cabling, fibre optic
into a large network without the need for a host or
node or communications between nodes. In cabling, and dedicated telephone line.
master controller. ThornNet is based upon a
the event of multiple failures, nodes will • Multiple communication topologies bus or ring.
combination of hardware and software that allows
automatically re-generate into independent
MINERVA fire controllers (Nodes) to be linked The MINERVA ThornNet communications network
fully functional networks.
together. The ThornNet supports up to 61,380 is a collection of network interface modules and
analogue/addressable points, 4,960 zones and • Automatic network re-configuration when a peripheral equipment that together form a
over 7,000 digital I/0 points. The network co- previously failed node is restored to the network.
ordinates and distributes alarm annunciation and network.
Product Codes
supervises system operation. When connected to • Up to 3,000 meters between nodes with
557.180.219
the network, each MINERVA controller maintains twisted/shielded cable.
its full stand-alone features, functions and ThornGraph PC to TLK-530-G connection cable
• System will operate on standard 2 core MICC.
capabilities. 557.180.148.A
• MINERVA controllers may be grouped into
Features sub-nets where each panel is programmed to TLO/TLD housing for a combination of 2 x
• LPCB approved inter-act only with other selected controllers. TLO530 or TLD530 Communication interfaces
(ADT branded)
• A peer to peer network that does not use a • Plug-in module (TLK-530) easily connects a
host or master controller. MINERVA fire controller to the network. 557.180.148.T
• 62 nodes, 61,380 points, 4,960 zone capacity. • Data is re-generated at each MINERVA TLO/TLD housing for a combination of 2 x
controller and is sent out over the ThornNet as TLO530 or TLD530 Communication interfaces
• Virtual Front Panel (VFP) enables an operator
new clean data. All degradation in received (available Thorn branded)
to interrogate and control any MINERVA
controller from the keypad/display of any other data due to noise on a line, line attenuation, or 557.180.147
MINERVA controller. phase shifting is eliminated when the data is Spare TLK -530 firmware Version 2.36
re-generated.
• Bi-directional signaling.
• The ThornNet uses a token-passing, non
• Open/short circuit isolation. Datasheet - Product Code PSF81 “ThornNet”
collision communication protocol for data
• Open/short circuit location. transmission. Manual - Vol07A-04-D1 “Communications
• Events originating at any MINERVA controller Systems Manual”
• "Network zones" and "sectors" allow the
can be used as an input to event/action network controllers to be configured as a

TLK-530
The key hardware component that makes the
network possible is the TLK-530 module. The
TLK-530 provides the electrical/mechanical means
to connect the components of the network to local
and remote network signalling circuits. Installation
of the TLK-530 is simplified with an edge
connector that plugs onto the main processor
board of the MINERVA controller. The TLK-530
provides RS-485 communications over a twisted
shielded pair as a standard configuration. The
distance between controllers can reach 3,000 557.180.215 557.180.218
meters at a speed of 38.4 Kbs using 18AWG
TLK530 ThornNet network node interface module TLK 530G ThornNet interface for ThornGraph PC
twisted shielded cable.
(Note: Functionally the same as TFX-TLI530) c/w 240V PSU and housing
Fits within the MINERVA housing.
TLO-530
The Fibre Optics Module (TLO-530) is used to at 38.4 Kbs at distances as high as 4,000 meters
interface one fibre optic channel to the TLK-530 between controllers.
module. The TLO - 530 fibre optic interface Up to two units can be fitted into a TLO/TLD
module converts RS-485 digital data current Housing which has a chassis plate to
pulses from the TLK-530 network interface accommodate the units.
module to light pulses. The light pulses are then Technical Specification
carried over fibre optic cabling to another TLO- Dimensions: 210H x 130W x 30D mm
530 where the pulses are converted back to RS- Product Codes
485 digital data current pulses. Two TLK-530
557.180.698
modules are required per panel for redundant
TLO 530 ThornNet fibre optics interface assembly
path star connections and when using fibre optics
in both directions of ring and bus connections. 557.180.148.A
Two (2) type 62.5/125 fibres between controllers TLO/TLD Housing - ADT branded
(4 fibres when using redundant path star 557.180.148.T
connections) allow the interface to transmit signals TLO/TLD Housing - Thorn branded

TLD-530
The Telephone Line Drive Module (TLD-530) is Technical Specification
used to interface two (2) dedicated telephone line Dimensions: 170H x 120W x 20D mm
circuits to the TLK-530 module. The TLD-530 line
Product Codes
driver module converts the RS-485 signals
received from the TLK-530 network interface 557.180.699
module to signals capable of being transmitted TLD 530 ThornNet direct line driver PCB
over the telephone line circuits.One TLK-530 557.180.148.A
supports two channels so only one module is
TLO/TLD Housing - ADT branded
required per controller for both single path and
redundant path star connections. The interface 557.180.148.T
allows for field configured baud rates and TLO/TLD Housing - Thorn branded
supports distances of up 3,000 meters. Up to two
units can be fitted into a TLO/TLD Housing

Page 4
tyco Fire & Tyco Electronic
Security Product Group
MINERVA Analogue Addressable Fire Controllers
Features
• 8, 16 & 80 Zone networkable controllers
• Seamless peer to peer networking
• Full function repeaters
• LPCB Approved
• T890/891 Marine Approved variants
• NEW Mandarin option
• Loop power sounder options
• Wide range of addressable devices
• Conventional system upgrade path
• Twin microprocessor watchdog function
• Continuous and pulsing sounders
• Programmable mapping of signals for
controlled evacuation
• On-site software configuration
• Powerful cause and effect software
programming
• Remote printer, mimic and VDU options
• 500 event memory
MINERVA is a comprehensive and reliable range The controllers and ancillaries are LPCB and • Pre-alarm capability
of networkable analogue addressable fire Marine approved with various other international
• Threshold compensation for optimum detector
controllers with over 10,000 installations cross listings.
performance
worldwide. MINERVA complies with BS5839 Pt 4
and can be installed to BS5839 Pt. 1. • Detector condition monitoring advises when
detector servicing is required
Technical Specification • Weekly test reminder and walk test facility
LPCB Approved MINERVA 8 MINERVA 16E MINERVA 80 • Addressable intrinsically safe System 602
Marine Approved (Note4) - T891M T890M • Surface and flush mount options
Zones 8 16 80 Technical Specification (Excludes Marine)
Points 99 198 990 Dimensions: 320H x 440W x 140D mm
Zonal LED Display 8 16 80 Approx. Weight: 7Kg
LCD Display 80 Character 80 Character 80 Character Colour: Dawn Grey BS4800 10-A-03
Sounder Circuits (2 off) 500mA each 500mA each 500mA each Installation: Surface or Semi-flush
Alarm Relay (1 off) 30Vd.c. @1.5A 30Vd.c. @1.5A 30Vd.c. @1.5A Operating Temp: -10°C to + 55°C
Fault Relay (1 off) 30Vd.c. @1.5A 30Vd.c. @1.5A 30Vd.c. @1.5A Storage Temp: -20°C to + 65°C
Product Codes Humidity: Up to 95% RH (Non-
condensing)
Control Panel Surface Mounting 557.180.564 557.180.550 557.180.556
Housing Protection: IP43
Control Panel Flush Mounting 557.180.565 557.180.553 557.180.557
Mains Supply: 110V-120V/220V-240V a.c.
Marine Panel - 557.180.402 557.180.401
± 10% at 50/60HZ ± 5%
Repeater Panel Surface Mounting 557.180.566 557.180.554 557.180.558
Secondary Supply: 24V d.c. Nominal
Repeater Panel Flush Mounting - 557.180.555 557.180.559
NOTE: A self contained 3 amp switch mode
Marine Repeaters (T290/291) - 557.180.404 557.180.403 power supply together with 2 x 6 AH 12V or 2 x
10 AH 12V batteries may be fitted inside the main
Special Control Panel Variants - housing of the MINERVA 8 or MINERVA 16E -
Loop Powered Surface Mnt Panel Note 3 Note 3 557.180.569 (See Note 1 for battery fixing kits). The MINERVA
80 requires a separate housing for its power
Loop Powered Flush Mnt Panel Note 3 Note 3 557.180.570
supply. Batteries up to 2 x 15 AH 12V may also be
Panel with Arabic overlay - 557.180.568 557.180.567 fitted in this housing. See AC Power Module.
Panel with Dutch overlay 557.180.701 557.180.703 557.180.702
Panel with Mandarin graphics display - 557.180.575 557.180.576 Datasheet - Product Code PB56 “Minerva 8, 16,
16E, 80 Panels”
Additional Components
Manual - Vol015A-02-D1 “Minerva Range of
Note 1 : 557.180.055 MINERVA 8 and 16E battery fixing kit.
Analogue Addressable Fire Controllers”
557.180.065 MINERVA 80 battery fixing kit
557.180.410 T890 battery fitting kit
Note 2 : 557.180.203 Loop Powered MINERVA 80 panels come complete with a special Loop
Powered ALXM (loop card) . An additional loop power ALXM card
(MINERVA-557.180.203) is required for each additional 2 loops.
557.180.014 ALXM (2 loop) expansion card for standard MINERVA 80
557.180.424 ALXM (2 loop) expansion card for T890
Note 3 : 557.180.092 MINERVA Loop powered insertion module converts MINERVA 8 and 16E
to Loop Powered panels.
Note 4: 557.180.454 T890/891 Bulkhead mounting kit
557.180.405 T690M Marine Power Unit

Page 5
tyco Fire & Tyco Electronic
Security Product Group
MINERVA 8-16E-T891 - Functional Schematic

MINERVA 80- T890 - Functional Schematic

Page 6
tyco Fire & Tyco Electronic
Security Product Group
MINERVA Repeaters
The MINERVA fully functional repeaters are
available for all models of the MINERVA series
controllers. The repeaters are LPCB approved
and offer the same control and monitoring
facilities as the main panel. Each repeater
includes one MPIM Module and up to seven
repeaters can be attached to the remote bus of
the main panel.
The technical specification for the repeater is the
same as the main panel shown on the previous
page, product codes are also shown there.

MINERVA - Auxiliary Expansion Outputs


Datasheet - Product Code PB56 “Minerva 8, 16, 16E, 80 Panels”
Manual - Vol015A-02-D1 “Minerva Range of Analogue Addressable Fire Controllers”

Multi Purpose Interface Module (MPIM)


The Multi-Purpose Interface Module [MPIM] is All MPIMs come fitted with a PROM
mounted on the rear of the front cover assembly (557.180.052) which enables an MPIM to be used
and is used to provide interface facilities between with a serial printer. If retrofitting a MPIM without
the main processor card [MP] and a number of this PROM, for use with a remote printer, this chip
different peripherals. An MPIM must have its is required.
'Personality' [configuration] set by means of plug- Product Codes
in headers to suit the particular application and set
557.180.012
the device address. The board can perform a
number of functions, each 'Personality' being a MINERVA Multi Purpose Interface Module [MPIM]
different combination of these functions. 557.180.052
All MPIMs come fitted with Version 3.2 firmware MINERVA serial printer driver kit (Spare)
and a separate product code is available for 557.180.231
upgrades - refer to TIB 0360 if necessary.
Spare MPIM EPROM Version 3.2

Input/Output Expansion Cards (XIOM)


The I/O on the XIOM can be set in banks of 8 to
operate as follows:
• LED driver outputs (10mA source)
• Relay Driver Outputs (100mA sink)
• Voltage Monitor Input (8 - 30Vd.c. Normal)
• Volt Free Contact inputs
Technical Specification
Dimensions: 144H x 85W x 15D mm
Operating Temp: -10 to +65°C
Storage Temp: -20 to +65°C
The XIOM is a 16 universal input/output Relative Humidity: 95% RH (Non-Condensing)
expansion board. Up to 5 x XIOM cards can be
Product Code
driven from each MPIM subject to its personality
settings. 557.180.016
XIOM MINERVA Input/Output Expansion Module
16 Way

Remote Mimics
MINERVA addressable system. It is supplied as a Mimic is the local control facility which is not
single PCB, which may be mounted in an featured in a Mimic. Both Repeater and Mimic
expansion box or on the rear of a free-standing include audible and visible warning facilities.
panel, as required. It may be used to drive up to Technical Specification
80 zonal LED indicators, arranged in any
Dimensions: 235H x 190W mm
configuration, together with two FIRE LEDs, one
FAULT LED and one ISOLATE LED. These Operating Temp: -10°C to +55°C
indicators operate in the same manner as the Storage Temp: -20°C to +65°C
corresponding indicators on the panel. Relative Humidity: Up to 95% RH Non
A remote Mimic can be connected to the MPIM’s Condensing
configured as remote Mimic drivers via the remote Product Code
bus. Up to 16 MPIMs may be connected on to the
The 80-Way Mimic allows custom-made display 557.180.005
remote bus, each with a unique address [set on-
and presentation panels to be incorporated in the board]. The difference between a Repeater and a MINERVA 80 way mimic driver module

DC/DC Converter (DCCM)


The DC/DC Converter produces regulated d.c. Product Codes
supplies from the ACPM outputs for use by the 557.180.051
panel logic circuits. The DC/DC Converter is
MINERVA DC/DC converter module
normally supplied only with MINERVA 80 and is
fitted into the panel housing. A special version is 557.180.205
available for loop powered MINERVA systems. An MINERVA loop power DC/DC converter module
additional DC/DC converter may be used to
supply power to two additional MPIM cards.
Page 7
tyco Fire & Tyco Electronic
Security Product Group
AC Power Module (ACPM)
Humidity: Up to 95% RH non-
condensing
Housing Protection: IP43
Mains Supply: 110-120/220-240Va.c. ±10%
50/60Hz ±5%
Charger Current: 2.7A @27.6Vd.c.
Product Codes
557.180.001
MINERVA power module - non addressable
ACPM
Addressable versions of the ACPM are available. 557.180.561
The AC Power Module [ACPM] is common to all This unit reports fault conditions to the control MINERVA surface mounting power box complete
MINERVA addressable models and supplies panel via the addressable loop. with non addressable ACPM
power to all the PCBs and other devices fitted. It Technical Specification 557.180.002
contains an integral battery charger which Dimensions: 320H x 400W x 140D mm MINERVA power module - addressable ACPM
continuously charges back-up batteries. These Colour: Dawn Grey 557.180.560
are required to supply the system in the event of a
Operating Temp: -10 to +55°C MINERVA surface mounting box complete with
mains failure, in order to comply with the
requirements of BS 5839 Part 1 [1988]. Storage Temp: -20 to +65°C addressable ACPM

Remote LCD Displays


• Provides an internal log of up to 150 events condensing
• Provides internal audible warning of an event Power Supply: 200mA @24Vd.c.
• Allows the event log to be scrolled
Ext. Sounder relay: 500mA @24Vd.c.
• Local internal buzzer silence
• Connects to host panel's RS232 port EMC: BS EN50081-1 and 50082-1
(maximum cable length between panel and Product Codes
first repeater of 15m) 557.180.035.A
• Provides an external sounder to mimic the
Remote LCD Repeater - ADT branded
internal buzzer
• Can be connected to an unlimited number of 557.180.035.T
other LCD Repeaters by using the Remote LCD Repeater - Thorn branded
RS232/RS422 converter (up to 1200m 557.180.062
The Remote LCD Repeater Module is designed to between repeaters) MINERVA MPIM to printer lead (D type 25 way
provide an independent scrolling log of system The LCD repeater must not be used in the male)
status at numerous points within a building or site. primary fire path. It must not be used as the sole
warning that a fire exists. 557.180.667
The module interfaces directly to a serial printer
Technical Specification: MINERVA MPIM to printer/PC lead (D type 9 way
port of the MINERVA addressable fire panel. If a
female)
local printer is already connected to the Panel's Dimensions: 200H x 150W x 75D mm
MPIM serial port, a second MPIM must be used. 557.180.152
Material: Bayblend
Features polycarbonate/ABS alloy 9 way gender changer for 557.180.667
· Uses a back-lit 4x20 character alphanumeric Operating Temp: -10°C to +55°C 557.180.151
display Relative Humidity: Up to 95% RH non- RS232/422 converter for LCD Repeaters

MINERVA Printer Options


WALL MOUNTED PRINTER 557.180.076.T
The unit is designed to provide a wall-mounted MINERVA Wall Mounted Printer (Thorn branded)
printing facility for the MINERVA analogue 557.180.202
addressable fire control panels. The unit is
MINERVA MPIM to printer (wall mounted) lead
powered from 240V a.c. 50Hz and uses a 42
(right angled D type 25 way male)
column printer with an RS232 serial input. It is
designed primarily as a hard copy alarm/fault 557.180.079
logging facility. A serial printer cable is used to Bezel for flush wall mounted printer
connect the printer to an MPIM configured as a 557.180.223
printer driver.
MINERVA wall mounting printing ribbon (Spare)
Technical Specification
557.180.052
Dimensions: 320H x 170W x 140D mm
MINERVA Serial Printer driver kit
LOCAL PRINTER Colour: Dawn Grey
509.022.008
A serial port is also available from the controller's Operating Temp: 0°C to 40°C
Spare printer paper
MPIM, which may be used to drive a serial printer Storage Temp: -15°C to 40°C
or a terminal/computer. In cases where more than
one printer is required locally, it is possible to Relative Humidity: 10% to 90% RH
"piggy-back" an additional MPIM onto the MPIM [non-condensing]
on the front panel and this will, when connected to EMC: BS EN 50081-1 and BS EN 50082-1
the local bus, provide the interfaces (up to a max Operating Voltage: 180V to 264V a.c.
of 8) for additional (printer) equipment. Protection: External 2 Amp fuse
REMOTE PRINTER Power: 20W
If it is required to have printers positioned at a WARNING:The mains supply must be from the
remote location, an MPIM must be used. This same source as the MINERVA control panel and
MPIM has its address set on-board and is be isolated by the same device. The serial printer
connected to the controller's remote bus. The cable must be run in metal conduit to comply with
connections between a MINERVA controller and the EU EMC Directive (89/336/EEC).
remote printers are shown in the diagram below.
Product Codes
An additional DC/DC converter module would
typically be required to power the MPIM (the 557.180.076.A
DC/DC converter can power two MPIM cards). MINERVA Wall Mounted Printer (ADT branded)

Page 8
tyco Fire & Tyco Electronic
Security Product Group
Desktop Printer
performance with paper handling flexibility and Weight: 4.3kg
quiet operation. Operating Temperature: 0°C to 40°C
Features Storage Temperature: -15°C to 40°C
• 240 cps draft/ 80 cps LQ. Relative Humidity: 10% to 90% RH
• Quiet operation [non-condensing]
• Lightweight and compact design
Operating Voltage: 180V to 264Va.c.
• 9 LQ fonts
• 2 paper feed paths EMC: BS EN 50081-1 and BS EN 50082-1
• Convertible push/pull tractor Product Codes
• Paper guide 557.180.214
• Auto loading
MINERVA printer LQ-300
• Paper park
• Cable feed recess 557.180.220
• Epson LQ standard terminal emulation LQ80 ribbon black (spare) for use with desktop
available printer.
The printer is designed as a low cost business • Parallel and serial interface 557.180.062
printer ideally suited for mounting adjacent to the Technical Specification MINERVA MPIM to printer lead (D type 25 way
fire control panel.The LQ-300 combines high Dimensions: 141H x 366W x 275D mm male)
Pager Interface
be used. The pager system requires a +12V d.c. Technical Specification
connection (from the MINERVA) and a serial port Dimensions: 328H x 190W x 75D mm
connection. If the transmitter needs to be located
System operating voltage: 12 to 13.8 Vd.c.
further than 2 m from the MINERVA, then a non-
standard serial printer cable may be used, up to a Effective radiated power: 500mW
maximum distance of 14m. Frequency range: 50-470 MHz
CAUTION: Before any installation is carried out, Channel spacing: 25KHz
an on site radio paging license must be obtained TX baud rate: 512 or 1200
by the customer. Care should be taken when
Type approval ETS 300 224, MPT1383 Cert No
designing pager systems. Normal practice
13249, EC type approved to ETS 300 682
indicates that a site survey should be done.
Approval No. 13331
Contact Product Management for additional advise
on site surveys. Product Codes
The Type A alarm pager can display alarm/fault 577.002.001
messages. The Type A maintenance pager Pager Transmitter
displays all messages sent by MINERVA. 577.002.002
The pagers:- Type A alarm pager
• Display messages sent out by the MINERVA 577.002.003
as displayed on the panel on the 4x20 LCD Type A maintenance pager
• Internal log of up to 40 events
• Audible and/or vibrate warning of event 577.002.006
• Allows the event log to be displayed. Pager aerial standard up to 500 metres
The transmitter:- 577.002.007
• Connects using a 9way D type MINERVA Pager aerial 60 db gain up to 1km
The MINERVA pager system is designed to
interface lead
provide a facility to signal all text messages or 577.002.008
• Can be setup for transmission to Type A
alarm/fault messages from a local transmitter to Optional feeder cable
• Using standard aerial, provides a 500 metre
the pagers.
sphere of transmission in open air
The transmitter connects to the serial printer port
of an MPIM, if a local printer is connected to the Manual - Vol08A-05-D1 “Ancillaries Manual”
controllers MPIM serial port, a second MPIM must

MINERVA CONSYS and Firmware


The function of the Consys configuration software dongle. Additionally variants also exist which Product Codes
is to customise a MINERVA addressable panel restrict access to Consys features i.e. customer 557.180.063
system to the requirements of the customer. and distributor variants. MINERVA MPIM to PC (D25) serial lead assembly
Configuration is performed on the basis of data A number of Consys variants are available e.g.
obtained from the customer. This data should 557.180.667
UK (non-dongled), UK dongled, UK Customer, UK
have been documented by the system designer MINERVA MPIM to PC (D9) serial lead
distributor, US (non-dongled), Dutch (non-
using the form 180s (available from the website) dongled), Marine (dongled). 557.180.105
and includes the following information: MINERVA full CONSYS software key (dongle)
Registered copies of the Consys configuration
• The number and location of detectors and software are available from the technical 557.180.106
other ancillaries. distribution department, TEPG Walthamstow, MINERVA customer/distributor software key
• The addresses of the above devices London E17 Tel +44 (0) 208 919 4004. (dongle)
• The 'zoning' requirements
Datasheet - Product Code PB56 “Minerva 8, 16, 557.180.225
• The number and location of any interface 16E, 80 Panels”
boards Customer CONSYS pack vers 12.0
• The addresses of the above boards Manual - Vol015A-02-D1 “Minerva Range of
Analogue Addressable Fire Controllers” and
• Bell mapping options
Vol011A-01-XX “Software Operating Manual”
• Co-Incidence grouping
• System fire options Firmware
• Network configuration
Upgrade M8 M16E M80 ALXM
This information is fed into 'CONSYS' and stored
on a floppy disk. This disk can be used with a Ver 10.1 557.180.127 557.180.128 557.180.129 557.180.130
laptop computer and downloaded into the panel Ver 11.0 557.180.134 557.180.135 557.180.136 557.180.137
via a download lead. Most laptop computers have
Ver 11.1 557.180.138 557.180.139 557.180.140 557.180.141
9 way serial comms ports, but sometimes one
may require a 25 way serial download lead. A Ver 12.0 557.180.830 557.180.831 557.180.832 557.180.833
"dongled" variant of Consys exists which only Ver 12.1 557.180.154 557.180.155 557.180.156 557.180.157
permits Consys to be installed on PCs with a Ver 12.2 557.180.158 557.180.159 557.180.160 557.180.161
Page 9
tyco Fire & Tyco Electronic
Security Product Group
Housings
MINERVA panels are supplied with a housing.
Matching dawn grey housings are available for
housing other equipment along side the MINERVA
panel. The general purpose housing is available
in surface and flush models with matching diecast
door.
Other housing options include the terminal
chamber PCB which provides neat terminations
for addressable loop field wiring.
The optional gland cover provides a neat
installation for the surface mount installations and
the 19ý rack mount kit allows the surface mount
MINERVA panel or general purpose housing to be 557.180.452 557.180.032
fitted in a 19ý rack. MINERVA general purpose housing surface
MINERVA Marine 19"rack mounting kit for use with
Product Codes surface mounting housings
557.180.033
MINERVA general purpose housing flush

557.180.021 557.180.034
557.180.022
MINERVA plain cover assembly for use with MINERVA expansion housing surface
MINERVA terminal chamber PCB assembly
general purpose housings - see below

Datasheet - Product Code PB56 “Minerva 8, 16,


Marine Housing Options
16E, 80 Panels”
557.180.406 MINERVA Marine Terminal Chamber
Manual - Vol015A-02-D1 “Minerva Range of
557.180.410 MINERVA Marine Battery Fitting Kit Analogue Addressable Fire Controllers”
557.180.212 557.180.454 MINERVA Marine Bulkhead Mount
Gland cover to hide cable entry for use with
surface mounting housings

MINERVA Spares
The following additional items are available as 557.180.426 557.180.208
standard spares. Other components can be T890/891 marine applications unit MINERVA spare keys (used on MINERVA
supplied as specials. controllers mid '94 Onwards)
557.180.054
Product Codes 557.180.721
MINERVA 16 mounting plate kit
555.180.002 MINERVA 16E cover assembly dutch (spare)
557.180.200
MINERVA 16E front cover assembly 557.180.722
MINERVA main processor PCB no software fitted
557.180.408 (Available on BSO) MINERVA 80 cover assembly dutch (spare)
557.180.204
T890 Front cover assembly
Motherboard loop powered for use with MINERVA
555.180.003 80 (spare) Datasheet - Product Code PB56 “Minerva 8, 16,
MINERVA 80 front cover assembly 557.180.209 16E, 80 Panels”
557.180.407 (Available on BSO) Keyswitch assembly for use with MINERVA Manual - Vol015A-02-D1 “Minerva Range of
T891 Front cover assembly controllers (spare) Analogue Addressable Fire Controllers”
557.180.010
MINERVA 80 motherboard PCB

Page 10
tyco Fire & Tyco Electronic
Security Product Group
MINERVA Addressable Modules
An extensive range of ancillary modules has been dampers to be controlled, provide an interface to • Allows loop powering of sounders and/or beam
specifically designed for use with the MINERVA 8, shut down HVAC equipment. Other applications detector units
16E and 80 range of Fire Control panels. The include an interface between shopping centre • Monitoring of external equipment, e.g. smoke
M520 range of ancillary modules provide the tenants' premises and the landlords' central dampers
MINERVA Panel with a wide degree of systems control system. • Reduced installation cost
application flexibility. This allows the field With the high systems integrity offered on the • Removes the need for separate plant control
addressable loop from the control panel to both MINERVA Panel the command modules can also circuits
receive inputs to the system and control outputs be used to control a public address based building
from it. evacuation system. Datasheet - Product Code PSF86 “520 Series
This broad range of modules allows the scope of Ancillary Equipment” (unless otherwise indicated).
Features
the fire detection system to be significantly Manual - Vol08A-02-D* “Ancillaries Manual”
• Communications and control interface to
extended beyond a simple fire detector - alarm * Design section indicated next to product code.
MINERVA Fire Panels
sounder based alarm system. The command
• High Systems Integrity
modules enable fire doors to be closed, fire
• Allows remote sounder circuits

LI520 MK2- Line Isolator Module


loop. Line isolators should be used at the Technical Specification
boundary of each zone so that no more than a Powered: Loop
single zone is made inoperative during a short
Temperature Range: -10°C to 70°C
circuit condition. This feature is a requirement of
BS5839 Part 1 1988. The LI520 Mk2 is also fitted Operating Humidity: up to 95% RH non-
with a red LED to indicate locally when the condensing
isolator has been tripped. Dimensions: 60H x 84W x 14D mm
The maximum number of line isolators per Product Codes
MINERVA loop is 12. There are also two isolator 545.001.007
circuits built into the MINERVA control panel loop
MINERVA LI520 Mk2 line Isolator module
drivers (one for each end of the loop).
545.001.009
The LI520 Mk2 line isolator is used to ensure that The LI520 Mk2 takes its operating power from the
LI520/M520 line isolator and cover assembled
a short circuit fault on the addressable loop will MINERVA loop.
not cause a total systems failure. LI520 Mk2's The module is not addressable and will therefore
effectively contain the fault to specific areas of the not take an address on the loop. Manual - Vol08A-02-D2 “Ancillaries Manual

CM520 - Contact Monitoring Module


The CM520 module provides the facility to monitor Technical Specification
an external contact, e.g. fire door monitor. This Powered: Loop
monitored point can then be used as a control Temperature Range: -10°C to 70°C
input for the MINERVA panel which is activated Operating Humidity: up to 95% RH non-
when the monitored contact is either open or condensing
closed. A delay between the monitored contact Dimensions: 60H x 84W x 14D mm
opening/closing and the activation of the control
Product Codes (Vol08A-02-D3)
input can be specified within the control panel
555.180.021
settings. The CM520 takes its operating power
CM520 contact monitor module (1 input)
from the MINERVA loop. The module is
addressable and will therefore take one address 555.180.026
on the loop. CM520/M520 contact module and cover
assembled

TM520 - Timer Module


The TM520 provides an output that can be The TM520 requires a separate 24Vd.c. supply to
activated based on a delay time. If either the key- operate. The module is not addressable and will
switch on the module is activated, or a predefined therefore not take an address on the loop.
event within the control panel occurs then a timed Technical Specification
delay (set between 10 minutes and 21 hours 10 Powered: 24Vd.c.
minutes) is started. When the delay reaches zero Temperature Range: -10°C to 70°C
the TM520 output is activated. The unit sounds an
Operating Humidity: up to 95% RH non-
internal buzzer and shows a red LED when the
condensing
output is active, and shows a yellow LED when
Dimensions: 87H x148W x 14D mm
the timer is counting down. To provide a warning
that the delay is nearly over, the red LED and the Product Code (Vol08A-02-D16)
buzzer will pulse 5 minutes before the end of the 557.180.423
delay . TM520 timer module - non addressable

RM520 - Relay Module


The RM520 provides one volt-free change-over Technical Specification
relay contact rated at 1A @ 24Vd.c. Command Powered: Loop
signals to drive the relay are configured in the
Temperature Range: -10°C to 70°C
MINERVA control panel software with the trigger
point being defined as a detector or other event Operating Humidity: up to 95% RH non-
programmed into the system. The relay contacts condensing
are monitored and the state (activated/de- Dimensions: 60H x 84W x 14D mm
activated) is reported back to the control panel. Product Codes (Vol08A-02-D1)
The RM520 is also fitted with a red LED to
568.001.011
indicate locally when the relay is operated.
RM520 relay module (1 x 24Vd.c. rated relay)
Typical applications for the RM520 include fire
door control or lift control. The RM520 takes its 568.001.017
operating power from the MINERVA loop. The RM520/M520 relay module and cover assembly
module is addressable and will therefore take one
address on the loop.

Page 11
tyco Fire & Tyco Electronic
Security Product Group
DM520 - Conventional Detector Module
The DM520 is used to interface a single zone of Technical Specification
conventional detectors onto the MINERVA Powered: 24V d.c.
analogue addressable loop. This provides a cost
Temperature Range: -10°C to 70°C
effective and easy method of extending existing
conventional systems or a future upgrade path for Operating Humidity: up to 95% RH non-
new conventional systems. The DM520 is also condensing
fitted with a red LED to indicate locally when the Dimensions: 60H x 84W x 14D mm
associated conventional zone has entered an Product Codes (Vol08A-02-D2)
alarm condition. The DM520 requires a separate
517.035.012
24V d.c. supply to operate. The module is
addressable and will therefore take one address DM520 conventional detector module
on the loop. 517.035.018
DM520/M520 detector module and cover
assembled

MDM521 - Multi-DM Module


The MDM521 module is used to interface to operate. The module is addressable and will
conventional detection zones onto the MINERVA take as many addresses as there are zones being
analogue addressable loop in a similar way to the monitored (i.e. between 1 and 8).
DM520. The MDM521, however, can be Technical Specification
configured to interface up to 8 zones of Powered: 24Vd.c.
conventional detectors rather than the DM520's Temperature Range: -10°C to 70°C
single zone. The module has an LED for each of Operating Humidity: up to 95% RH non-
the 8 zones which will show red when the zone is condensing
in alarm and yellow if the zone is in fault. This Dimensions: 290H x 88W x 30D mm
module provides a cost effective method of Product Code (Vol08A-02-D25)
interfacing several conventional zones onto an 517.035.017
addressable loop.
MDM521 Multi circuit conventional detector
The MDM521 requires a separate 24Vd.c. supply module

SM520 - Sounder Driver Module


The SM520 module is used to provide an output Technical Specification
to alarm sounders or visual warning devices in Powered 24Vd.c.
response to a control signal from the control Temperature Range -10°C to 70°C
panel. The devices are controlled directly from the
Operating Humidity up to 95% RH non-
SM520 on the addressable loop rather than from
condensing
outputs on the control panel, thereby significantly
reducing wiring costs. The output wiring to the Dimensions 60H x 84W x 14D mm
alarm devices is fully monitored and the module Alarm load max: 24Vd.c. @500mA
has the capability to drive up to a maximum of Product Codes (Vol08A-02-D6)
500mA alarm device load. If higher alarm device 577.001.022
loads are required then an SB520 sounder SM520 sounder driver module
booster module must be used in conjunction with 577.001.032
the SM520. The SM520 requires a separate
SM520/M520 sounder module and cover
24Vd.c. supply to operate. The module is
assembled
addressable and will therefore take one address
on the loop.

SB520 - Sounder Booster Module


The SB520 sounder booster module is used in Technical Specification
conjunction with the standard SM520 to drive one Powered: 24Vd.c.
or more alarm sounder devices from the Temperature Range: -10°C to 70°C
addressable loop rather than directly from control
Operating Humidity: up to 95% RH non-
panel outputs. The SB520 is required when the
condensing
alarm sounder load to be driven from the SM520
is greater than 500mA. Using the SB520 Dimensions: 60H x 84W x 14D mm
increases the sounder load capacity to 15A. Alarm load max: 24Vd.c. 15A
The SB520 requires a separate 24Vd.c. supply to Product Codes (Vol08A-02-D7)
operate. The module is not addressable and will 577.001.023
therefore not take an address on the loop. SB520 sounder booster module
577.001.033
SB520/M520 booster module and cover
assembled

LPS520 - Loop Powered Sounder Module


The LPS520 module provides control outputs for Technical Specification
alarm sounders in the same way as the SM520 Powered: Loop
module, except that no external power supply is
Temperature Range: -10°C to 70°C
required as the sounders draw their power directly
from the addressable loop. A maximum of 4 Operating Humidity: up to 95% RH non-
LPS520 modules can be used per loop, each condensing
driving a maximum of 6 Banshee sounders each. Dimensions: 60H x 84W x 14D mm
The LPS520 takes its operating power from the Product Code (Vol08A-02-D19)
MINERVA loop. 577.001.027
The module is addressable and will therefore take LPS520 line power sounder module
one address on the loop.

Page 12
tyco Fire & Tyco Electronic
Security Product Group
LPBD521 - Loop Powered Beam Detectors
power the analyser unit, the beam receiver unit Product Code
and the transmitter unit. Alternatively, two 557.180.217
separate LPBD521's can be used with one to
LPBD521 loop powered beam detector interface
power the analyser unit and receiver units and the
module for use with FireRay 2000
second to drive the transmitter separately, either
from the same loop or a different loop. Up to 8
LPBD521's can be used per loop. Datasheet - Product Code PSF85 “Fireray 2000
The module is addressable and will therefore take Optical Beam Smoke Detector”
one address on the loop. Manual - Vol08A-02-D22 “520 Series Ancillary
Technical Specification Equipment”
Powered Loop
Temperature Range -10°C to 70°C
The LPBD521 module is used to drive the FireRay Operating Humidity up to 95% RH non-
2000 beam detector units directly from the condensing
MINERVA loop. A single LPBD521 can be used to
Dimensions: 60H x 84W x 14D mm

AM521 & AM921 Addressable Aspirating Interface


The AM921 module is used as an interface Technical Specification
between the MINERVA control panel and the Powered: Loop
LaserPLUS and scanner aspirating detectors. The
Temperature Range: -10°C to 70°C
module is fitted inside the aspirating detectors
housing at the relay output location and also takes Operating Humidity: up to 95% RH non-
its power from the detector unit. condensing
The AM521 module is used as an interface Dimensions 921: Fits in VLS/VLP
between the MINERVA control panel and an Dimensions 521: 77H x 100W x 15D mm
aspirating detector of types like the E70D or Hart Product Codes (Vol08A-02-D13)
Unilazer. The module is fitted inside the aspirating
546.017.001
detector housing and also takes its power from
the detector unit. AM521 aspirating interface module
The AM521 will provide alarm, pre-alarm, and 546.004.007
fault status signals for use in the MINERVA panel. AM921 aspirating interface module
The module is addressable and will therefore take
one address on the loop.

PI521 - Plant Interface Module


The Plant Interface module is an addressable, addresses on the loop; max per loop is 8)
multi input/output device that is used to interface All outputs are rated at 240V 5A. The PI521
plant equipment to the MINERVA control panel. requires a separate 24Vd.c. supply to operate.
Inputs can be used for plant monitoring whilst the
Technical Specification
outputs can be driven from the MINERVA control
panel as required. Powered: 24Vd.c.
Temperature Range: -10°C to 70°C
The module is configured in one of three Modes:
Operating Humidity: up to 95% RH non-
PI521/2 2 inputs and 2 outputs (Takes 4 condensing
addresses on the loop; max per loop is 24)
Dimensions: 72H x 245W x 23D mm
PI521/4 4 inputs and 4 outputs (Takes 8 Product Code (Vol08A-02-D18)
addresses on the loop; max per loop is 12)
546.004.006
PI521/6 6 inputs and 6 outputs (Takes 12 PI521 MINERVA plant interface

SD520 - Smoke Damper Interface Module


The SD520 provides two monitored inputs and Technical Specification
one relay output rated at 240V @ 5A. The SD520 Powered 24Vd.c.
is ideally suited to driving smoke damper units Temperature Range -10°C to 70°C
directly from the MINERVA loop. One of the inputs
Operating Humidity up to 95% RH non-
can optionally be used to monitor the action of the
condensing
module relay externally, i.e. at the smoke damper
unit. The SD520 is fitted with a red LED to Dimensions: 60H x 84W x 14D mm
indicate locally when the relay is operated. Relay output rating: 240Va.c. @ 5A
The SD520 requires a separate 24V d.c. supply to Product Codes (Vol08A-02-D17)
operate. The module is addressable and will 568.001.014
therefore take one address on the loop. SD520 smoke damper interface module ( 2 inputs
and 1 output)
547.004.001
DIN rail mounting kit for use with PI521 or SU521

Page 13
tyco Fire & Tyco Electronic
Security Product Group
SU521 - Shop Interface Module
The SU251 is an addressable, multi input/output All outputs are change-over contacts rated at 24V
device that is used to interface other fire or 1A. The SU521 takes its operating power from
security systems into the MINERVA control panel. the MINERVA loop.
Inputs can be used for taking signals from other Technical Specification
systems (e.g. taking individual shop security
Powered: Loop (0.54mA)
systems into the central shopping centre system)
whilst the outputs can be used to send control Temperature Range: -10°C to 70°C
signals from the MINERVA back to the individual Operating Humidity: up to 95% RH non-
tenant's system. The SU521 can be configured in condensing
one of three formats: Dimensions: 72H x 245W x 17D mm
SU521/2 2 inputs and 2 outputs (Takes 4 Product Codes (Vol08A-02-D15)
addresses on the loop; max per loop is 24)
568.001.013
SU521/4 4 inputs and 4 outputs (Takes 8
SU521 shop unit interface
addresses on the loop; max per loop is 12)
547.004.001
SU521/6 6 inputs and 6 outputs (Takes 12
addresses on the loop; max per loop is 8) Din rail mounting kit

Ancillary Covers and Housings


557.180.096.T
ANC-8 MINERVA ancillary housing Thorn
Branded
557.180.095
STK-8 MINERVA ancillary stacking kit for use with
ancillary housing 557.180.096
557.180.097.A (Vol08A-02-I1)
ANC-3 MINERVA ancillary housing ADT Branded
557.180.097.T (Vol08A-02-I1)
ANC-3 MINERVA ancillary housing Thorn
Most M520 modules can be fitted to a double Branded (See picture)
gang MK style backbox using the M520 ancillary
cover. Where several devices are mounted in one Product Codes
place the ANC3 houses 3 x M520 modules and 517.035.007
the ANC8 houses 8 modules, expandable to 16
M520 Ancillary cover for use with M520 modules
using the STK8 stacking kit.
557.180.096.A
ANC-8 MINERVA ancillary housing ADT Branded

Minerva Loop and Zone Labelling


599.047.004 Zone labels are affixed to address labels to
Label loop D green produce a combined address/zone label.
599.047.005 Product Codes
Label-loop E grey Zone Labels
599.047.006 599.047.011
Label-loop F blue Label zones 1-16
599.047.007 599.047.012
Label loop G orange Label zones 17-32
599.047.008 599.047.013
Label loop H red Label-zones 33-48
599.047.009 599.047.014
Label loop I dark blue Label-zones 49-64
599.047.010 599.047.015
Round address labels are used for fixing to Label loop J black Label-zones 65-80
addressable devices and are provided in 10
different colours to allow differentiation between
loop wiring.
Product Codes
Round Labels
599.047.001
Label loop A white
599.047.002
Label loop B yellow
599.047.003
Label loop C purple

Page 14
tyco Fire & Tyco Electronic
Security Product Group
Addressable Fire Systems - UL/FM Approved
Analogue Addressable TFX-400 Series
AUTOCALL TFX-400 meets the needs of any Technical Specification
small-to-mid size building or building complex; Note: AUTOCALL TFX-400 is intended for use
networking capability allows the TFX-400 to be within a building interior, free from exposure to
used in larger buildings or building complexes. moisture, condensation and excessive dust.
Features Operating Temp.: 0 to +49oC
. 198 Analogue addressable points Humidity: 85% Non-Condensing
. Fully upgradable Loop Styles: NFPA 72 Style 4 & 6. Line
. Ideal for retrofit applications isolators optional for short
. System status information at a glance circuit isolation
. One panel size with many features of larger Max. Add Per Loop: 99
TFX panels Max Loops per Sys: 2
. Compact cabinet fits between wall studs Operating Voltage: 26Vd.c., 300mA
. Cabinet space for up to 17 Amp hours of Supervisory Current: 20mA per loop (plus load)
battery 24mA per loop (plus load)
. Semiflush or surface mount flexibility Resistance: Max. 75Ohms
. Low cost Capacitance: Max. 0.5 microfarad (mutual)
Features - Options Inductance: Max. 1.5 millihenry (total)
. Remote OCP and virtual front panel Product Codes
. Networking capability 557.180.625
. Graphical user interface TFX400 Two loop UL/FM approved fire control
TFX400 Listings & Approvals panel. Supplied in grey with Thorn Security
. UL Listed, File S2561 branding.
The AUTOCALL TFX-400 is a self contained, - Local 976422
small addressable panel in a single cabinet. The - Local with Releasing Device Service TXF400 Two loop UL/FM approved fire control
AUTOCALL TFX-400 includes 2 analogue, - Auxiliary panel. Supplied in red with Grinnell branding.
addressable signalling line circuits that provide 99 - Remote Station (Protected Premises Unit)
points each. Proprietary (Protected Premises Unit)
The AUTOCALL TFX-400 uses proven technology, - Central Station (Protected Premises Unit)
used in the TFX-500M and TFX-800M fire alarm - Fire Alarm Control Unit
and detection systems. The AUTOCALL TFX-400 - Proprietary Receiving Unit
control is designed to be used with conventional or - Central Station Receiving Unit
analogue, addressable fire detection devices, in . CSFM No. 7165-1493:147
any combination. As a stand alone panel, the 7170-1493:167

Analogue Addressable TFX-500/800 Series


. Alarm resound by zone or device
. Modular, expandable
. Single, dual and multi-channel voice systems,
25 and 70 VRMS
. Networking capability to the graphical user
interface from any TFX panel.
Listings & Approvals
. UL 864 Listed for Local, Auxiliary, Remote
Station and Proprietary Receiving Station
Service; File S2561
. CSFM No. 7165-0062:161
. MEA No. 415-92-E
. FM ID No. OX2A8.AY
NOTE: AUTOCALL TFX-500M and TFX-800M are
intended for use within a building interior, free from
exposure to moisture, condensation and excessive
557.180.623 dust.
Features Technical Specification
. Conventional and analogue addressable fire Temperature Range: 0oC to 49oC
detection Relative Humidity: 85% Non Condensing
557.180.624 . 198 Analogue addressable initiating and output
devices plus 1600 discrete inputs or outputs Loop Styles: NFPA 72 Style 4 and 6. Line
The AUTOCALL TFX-500M, TFX-800M, TFX- isolators optional for short circuit isolation
(TFX-500M)
500MV and TFX-800MV comprise the AUTOCALL . 990 Analogue addressable initiating and output Max. Add. Per Loop: 99
TFX family of self contained controls for fire alarm devices plus 1100 discrete inputs or outputs Max. Loops Per Sys: 2 (TFX-500M)
and detection from Grinnell Fire Protection (TFX-800M)
Systems Company. 10 (TFX-800M
. TFX-500M may be expanded to TFX-800M on
The AUTOCALL TFX-500M provides up to 198 site Voltage: 26Vd.c., 300mA
analogue addressable initiating and output . 80 Character LCD display; 40 user defined Supervisory Current: 20mA per loop (plus load)
devices, while the AUTOCALL TFX-800M expands message characters Alarm Current: 24mA per loop (plus load)
the capacity to 990 devices. The basic system . Power limited, all circuits
Resistance: Max 75 Ohms
hardware and software is common for both . Integral LED zonal or group annunciator
. Degrade mode in TFX-800M operates Capacitance: Max. 0.5 microfarad (mutual)
AUTOCALL TFX-500M and TFX-800M, therefore
the 500M can be expanded to 800M on site. evacuation signals if CPU failure occurs before Inductance: Max. 1.5 millihenry (total)
or during an alarm Max. Continuous Dis: 6500 feet
AUTOCALL TFX controls are designed to be used
. Smoke detector condition monitoring with
with conventional or analogue addressable fire Product Codes
automatic environmental compensation
detection devices, in any combination thereof. 557.180.623
. Individual smoke detector sensitivity selectable
Engineered with advanced microprocessor TFX-500M 2 loop fire control panel with red
from the operator interface
technology, these fire control panels provide a architectural door. Grinnell branded in 3 tier
. Historical event log for view or print
dynamic level of applications flexibility. Grinnell’s housing with FCM/OCM and 16 LED indicator.
. Fully site programmable
Supplied complete with 4” shallow backbox. Other
exclusive CONSYS software configuration tool for . Solo test and alarm verification per group or
colours and branding available on request.
site specific user programming easily guides the point
557.180.624
trained installer through a menu prompted decision . Automatic time control functions with holiday
TFX-800M Fire detection panel with red
process. exceptions
architectural door and Grinnell branding in 7 tier
. Six access levels with unique 0911 Fire
housing with FCM/ODM and 80 LED indicator.
Department Access
Supplied rebuilt complete with 6” backbox. Other
. Automatic and manual detector sensitivity
colours and branding available on request.
adjustment
Page 15
tyco Fire & Tyco Electronic
Security Product Group
Remote Operator Control Panel
as well. All control functions are password . No/Delete button
protected. . Scroll up button
Functions available at the ODM include: . Scroll down button
. Per point annunciation of alarm and trouble . Yes/Enter button
events . Quit button
. View and acknowledge events which have not . Fast access button
been restored to normal Features - Optional 16-Indicator Module
. Force outputs on . Zone alarm LEDs - red
. View smoke detector analogue values in % . Zone trouble LEDs - yellow
obscuration per foot, and perform sensitivity Listings & Approvals
checks, NFPA 72 requirements . UL File No. S374
The Remote Operator Control Panel (remote
. View event history log . CSFM No. 7165-1493:147
OCP) is designed for use with the AUTOCALL
. Isolate zones and points 7170-1493:167
TFX series systems to provide system operating
. Enable Solo test mode . MEA 415-92-E, Vol. IX
controls at a remote location. The unit is suitable
. Enable maintenance mode . FM 3001053
for mounting in lobbies, vestibules or anywhere
. Print status and maintenance reports Technical Specification
were space is a premium. Three configurations are
. Change smoke detector sensitivity Operating Temp.: 0 to +50oC
available and each are housed in small, attractive
The optional 16-indicator module provides field Operating Humidity: 85% Non-Condensing
units, finished in red with a black faceplate. Each
configurable LEDs for annunciation by zone, Current Draw:
configuration is suitable for indoor semiflush or
group, device type or point. Since LEDs are bi- Standby Current: 50mA (FCM)
indoor surface mounting.
coloured (red and yellow), each LED may be 32mA (ODM)
All remote OCP configurations contain a fire
configured to annunciate alarm and trouble. Label 9mA (16-IM)
control module (FCM) to duplicate basic fire alarm
space is provided with each LED for custom Alarm Current: 65mA (FCM)
functions at a remote location. Control buttons with
identification. 32mA (ODM)
LEDs for panel silence, alarm silence, system
Features 34mA (16-IM)
reset, and drill are furnished. Labels for each Product Codes
. LEDs Fire alarm - red
control button may be field customised in 976401
Supervisory - yellow
languages other than English, or to meet on site
Fault - yellow TFX Remote operator control module
requirements. A lamp test button is also provided.
Isolate - yellow incorporating the fire control module (FCM) only.
LEDs for fire alarm, supervisory, fault and isolate 976402
Power-on - green
annunciation are furnished. A separate LED for
. Enable key switch TFX Remote operator control panel with fire
power on indication is also provided. In addition,
. Panel silence button and LED - yellow control module (FCM) and operator display
three programmable LEDs are available for
. Alarm Silence button and LED - yellow module (ODM).
annunciation of programmed actions. 976403
. System reset button and LED - yellow
The Remote OCP is also available with either an
. Drill button and LED - red TFX Remote operator control panel with fire
operator display module (ODM) or a 16 indicator
. Three programmable LEDs - yellow control module and 16 indicator LED module
module.
. Lamp Test (FCM/16IND).
The optional DM provides an 80 character, backlit 976404
. Internal buzzer
alpha-numeric, LCD operator display. The LCD
Features - Optional Fire Control Module TFX Semi flush backbox for use with all remote
provides user defined text messages of event type
. 7 Sockets accept red, yellow or green LEDs for operator control panels.
and precise location. An operator’s keypad allows 976416
special requirements
the user to acknowledge events, make inquiries,
Features - Optional Operator Display Module TFX Surface mount backbox for use with any
and view system status. The real time clock and
. Alphanumeric display remote operator control panel.
date settings are set and changed from the keypad
. Numeric touch pad

TFX Additional User Interface Module

9976130 9976132 9976134


Product Codes 9976136
9976130 TFX 80 Indicator module with one integral MPIM
TFX 40X2 Indicator with MPIM board. Provides an card for use on TFX-800M
additional 40X2 zone indicators for use with TFX- 9976137
500M or TFX-800M TFX 80 Way indicator module with 2 MPIM
9976132 modules built in
TFX 40 Way status control module and MPIM 976399
module for adding to TFX-500M or TFX-800M TFX MDM Mounting plate
9976134
TFX 16 Way status control module with MPIM for
use with TFX-500M or TFX-800M 9976136/997137

TFX Panel Components & Spares


Product Codes 940577 976262
19240410 TFX/CONSYS Programming cable with DB9 TFX SIM Serial interface module provides isolation
TFX PAM-2 EOL Relay female connector CONSYS software available on to serial printers
850509 document control. Contact Peter Cooke - TEPG 976399
TFX500 & 800M Field wiring guide Singapore or Nick Wright - TEPG Walthamstow TFX MDM Mounting plate
850515 976041
TFX500 & 800M Operator and installation manuals TFX PIM-550 printer interface module
850516 976076
TFX500 & 800M operators manual TFX CDM-800 Universal I/O expansion for use
with MPIM
976254
TFX Spare keys for use on TFX OCM and door

Page 16
tyco Fire & Tyco Electronic
Security Product Group
Power Supplies (See Note)

976122 976123 976040


The AUTOCALL Power supplies (models RPS-424 Features - DCPM . MEA No.: 415-92-E, Vol. VI (models
and DCPM) are solid state electronic power . Converts 24Vd.c. to voltages required by the RPS-424, 500PSM and
supplies which provide filtered regulated DC power TFX family DCPM)
to the AUTOCALL TFX series fire alarm system. . FM ID No.: OY9A3.AY (models RPS-
The RPS-424 converts 120Va.c. primary power to Features - 500PSM/PSM 424, 500PSM and PSM)
24Vd.c., 5Vd.c. and 15Vd.c. The DCPM converts . Provides visual indicators for RPS-424 power OX2A8.AY (model DCPM)
24Vd.c. power from the RPS-424 to the supply supply faults Product Codes
voltages necessary for the TFX family. . Mounts directly to RPS-424 power supply 910683
The power supply monitor modules (modules . 500PSM provides addressable interface to TFX TFX Spare dual voltage RPS-424 power
500PSM and PSM) monitor the RPS-424 and data circuits supply/charger used on all TFX panels
provide visual trouble indicators of faults. Listings & Approvals 976040
Features - RPS-424 . UL 864 Listed, File No. S2561 TFX DCPM DC/DC convertor for use as a spare or
. Converts 120Va.c. input power to d.c. . CSFM No.: with additional MPIM modules
operating power 7165-1493:147 & 7170-1493:167 976122
. Charges and supervises batteries (models RPS-424, 500PSM and PSM) TFX 500PSM Power supply monitor module
. Automatic transfer to battery during a.c. power 7165-1493:162 (model RPS-424) 976123
failure or brownout 7170-1493:168 (models DCPM, TFX PSM Power supply monitor module
. Unique voltage booster feature for notification 500SPM and PSM)
purposes
Technical Specification
RPS-424 DCPM 500PSM/PSM
Dimensions 112.5H x 187.5W x 50D mm 90H x 135W x 52.5D mm 123.5H x 56.25W x 25D mm
Input Voltage 120/240Va.c., 50/60Hz 24Vd.c. 24Vd.c.
Input Current 1.5A RMS 1.5A (approx) 62mA
Output Circuits +24Vd.c.@4A (non resettable)* +26Vd.c.@300mA N/A
(for panel connections only) +24Vd.c.@2A (resettable)* +12Vd.c.@100mA N/A
+15Vd.c.@100mA* -12Vd.c.@100mA N/A
+5Vd.c.@4A* +5Vd.c.@2A N/A
Output Circuits +24Vd.c.@2A (non resettable)* N/A +24Vd.c.@4A
(for field connections only) +24Vd.c.@2A (resettable)* N/A +12Vd.c.@100mA
N/A N/A +5Vd.c.@4A
Output Voltage 24Vd.c. regulated (+10%/-5%) N/A N/A
Supervisory Current Draw 100mA (unloaded) 50mA (unloaded) 62mA
Alarm Current Draw 100mA (unloaded) 50mA (unloaded) 62mA

* Total of output circuits must not exceed 5A alarm, 2.5A supervisory


NOTE: The RPS-424 will shortly be replaced by the
PSM800 for use with TFX panels. The PSM800
uses the APM500 addressable power supply
monitor module for use on TFX systems.

910683

Page 17
tyco Fire & Tyco Electronic
Security Product Group
Multi Purpose Interface Module
Features Operating Voltage: +5Vd.c., +12Vd.c., -12Vd.c.
. Remote (RS-485) and local bus communication Operating Current:
module Normal: 19mA
. Interface to annunciators, printers and Alarm: 24mA
Input/Output points Maximum distance from MP-500 (Main Processor
. Interface to remote operator display and control Board):
panels Local Bus: 60cm
. Up to 80 input/output points per MPIM Remote Bus: 2500m
. Up to 16 MPIMs on the remote bus Communications Method:
. Up to 16 MPIMs on the AUTOCALL TFX-500 Local Bus: Synchronous 1
series local bus MBit/sec
. Up to 11 MPIMs on the AUTOCALL TFX-800 Remote Bus: RS485, 4800
The AUTOCALL Multi Purpose Interface Module series local bus baud
(MPIM) is the communication interface between . May be installed up to 4000 feet remotely from Expansion Bus: Mulitplexed
the AUTOCALL TFX control panel and certain panel Serial Port: RS232, 4800
remote system functions. MPIMs communicate Listings & Approvals Baud
with the main processor module through the . UL Listed; File No. S2561 Product Code
system’s local or remote (RS485) bus. Each MPIM . CSFM No. 7165-1493:147 976015
module is assigned a unique bus address by 7170-1493:167 TFX-MPIM Multi purpose interface module for
means of programming jumpers. . MEA No. 415-92-E Vol. VI driving additional LED indicators, status control
The MPIM mounts in the AUTOCALL TFX panel . FM ID No. OX2A8.AY modules, I/O expansion and printers. Refer to
enclosure, a local or remote AUTOCALL TFX Technical Specification manual for limitations
display panel enclosure, or a suitable listed Dimensions: 165H x 91W x 25D mm
enclosure. It connects to the local or remote bus of Operating Temp.: 0oC to +50oC
an AUTOCALL TFX system. Operating Humidity: 85% (Non Condensing)

Loop Expansion Board


Features
. Two signalling line circuits
. 99 Addressable analogue devices per circuit
. Degrade mode operation in the event of main
processor board failure
Listings & Approvals
. UL File No. S2561
. CSFM No. 7165-1493:147
7170-1493:167
. NY MEA No. 415-92-E, Vol. II
976062 . FM ID No. JI OX2A8.AY
AUTOCALL’s ALXM Loop Expansion Board Technical Specification
(model IIB-800) is used to expand the capacity of Dimensions: 216H x 153W x 12.5D mm
the AUTOCALL TFX-800 system. Each board Operating Temp.: 0 to +50oC
provides two signalling line circuits, each with a Operating Humidity: 85% Non-Condensing
capacity of 99 addressable analogue devices, 976063 Input voltage: 5Vd.c., 24Vd.c.
such as smoke detectors, water flow switches, pull circuits. In the event of a failure of the AUTOCALL (from IAM-800)
stations and supervisory devices. Up to 5 IIB-800 TFX-800 series main processor board, the IIB-800 Operating Current: 50mA
boards may be installed in an AUTOCALL TFX is capable of operating indicating appliance Product Codes
series system, for a total of 990 devices. modules on the same signalling circuit in which an 976062
The IIB-800 is an intelligent module. It has its own alarm has occurred, and will signal a common TFX IIB-800 Two loop addressable expansion
microprocessor and uses distributed processing alarm or trouble condition by operating common module for use as a spare or expanding the TFX-
techniques for signal processing and analysis. On alarm and trouble relays on the IAM-800 800M to a maximum of 10 loops
board non-volatile memory stores the addresses of Expansion Motherboard. 976063
the devices on each of the two signalling line TFX IAM-800 Additional/spare motherboard for
TFX-800M

Discrete I/O Modules


custom graphic or zonal annunciator and wired to Listings & Approvals
indicating LEDs. The input events which relate to . UL File No. S2561, all models 1/A
the LED outputs are completely field IAA-16
programmable. . CSFM No. 7165-1493:147
These inputs may be alarms, supervisory . NY MEA No. 415-92-E, Vol. VI
conditions, general trouble conditions, special . FM ID No. JI OX2A8.AY
trouble conditions such as missing devices or AC OAA-16
power failure, and non-alarm/non-trouble inputs. . CSFM No. 7165-1493:147
The XAA-16 provides 8 inputs/8 outputs. Outputs . NY MEA No. 415-92-E, Vol VI
are rated for 6mA at 24Vd.c. (suitable for relays . FM ID No. JI OX2A8.AY
and other 24Vd.c. devices). Total current of all 8 OMA-80
AUTOCALL’s discrete I/O modules are used with
outputs must not exceed 500mA. . CSFM No. 7300-1493:152
the AUTOCALL TFX series systems. The modules
Features . NY MEA No. 415-92-E, Vol. VI
include the following model numbers: IAA-16
. 16 Contact closure inputs (IAA-16) Product Codes
(XIOM 16 Input Module)), OAA-16 (XIOM 16
. Programmable LED driver outputs (OAA-16 976067
Output Module), OMA-80 (Custom Graphic Driver
and OMA-80) TFX IAA-16 Digital input expansion board for use
Board) and the XAA-16 (8 Input/8 Output Contact
. 8 Contact closure inputs and 8 programmable with MPIM
Monitor/Relay Driver Module - XIOM).
outputs 976066
The IAA-16 XIOM 16 Input Module is used to
. LED Outputs user configurable for TFX OAA-16 Digital output expansion unit for use
interface with normally open contact devices such
annunciation by zone, point or user-defined with MPIM
as HVAC fan controls and speaker zone select
group 976077
switches.
. 4 System condition LED driver outputs TFX OMA-80 Mimic driver PCB for use with MPIM
The OAA-16 and the OMA-80 modules are used in
. Up to 4000 feet (2500m) remote from panel 976098
AUTOCALL TFX series systems to annunciate
TFX XAA-16 8 Input and 8 output expansion board
events by a single device or by user defined
for use with MPIM
groups or zones. They are typically installed in a
Page 18
tyco Fire & Tyco Electronic
Security Product Group
Technical Specification

IAA-16 OAA-16 OMA-80 XAA-16


Dimensions 141H x 84W x 18.5D mm 141H x 84W x 18.5D mm 231H x 188W x 12.5D mm 141H x 84W x 18.5D mm
Operating Temperature 0 to +50oC 0 to +50oC 0 to +50oC 0 to +50oC
Operating Humidity 85% Non-Condensing 85% Non-Condensing 85% Non-Condensing 85% Non-Condensing
Input Voltage from MPIM 5Vd.c. 5Vd.c. 5Vd.c. 5Vd.c.
Input Current 11mA plus 5mA 11mA plus 10mA 11mA plus 10mA 9mA plus 5mA (per configured
(per active input) (per active output) (per active input) input plus 50mA per active o/p)
Output Current per LED - 10mA 10mA -
Output Current per output - - - 100mA
(not current limited)

TFX Fire Alarm System Network


Features . Up to 3 panels can be configured to provide full
. Half duplex, token passing protocol system annunciation, control and logging;
. Peer-to-peer operation configuring two panels as identical receiving
. Automatic fault recovery units provides hot-backup of central monitoring
. Field configured baud rates up to 38.4K baud equipment
. Asynchronous, 1 stop bit, 8 data bits, no parity . ‘Virtual Front Panel’ (VFP) feature allows
. Deterministic performance operator interrogation and control of any panel
. Self-configuring from any other panel
. Error detection and recovery . All TFX-500 and TFX-800 features and
. Short circuit isolation at each node capabilities are retained
. Open/short circuit detection identifies the . TFX Panels can be configured with integrated
TFXnet is a collection of network interface
location of the fault single and multiple channel voice and audio
modules and peripheral equipment that together
. Nodes automatically disconnect from the evacuation equipment as well as integrated
form a robust, fault resilient and flexible peer-to-
network at loss of power and when addressable firefighters telephone system
peer communications network.
experiencing a catastrophic failure Features - Optional Equipment
Operation
Features - TFXnet Communications . PC Based graphical user interface (Firegraph)
TFXnet employs a token passing communications
. True peer-to-peer communications, no host or connects directly to the TFX network
protocol that treats each node equally. Loss of one
master controller Listings & Approvals
or more nodes does not affect operation of the
. Node failure does not affect remainder of . Rind and redundant path star topologies meet
remainder of the network. The network will
network NFPA 72 Class A, Style 7 signalling circuit
automatically re-configure when a node is inserted
. Groups of nodes isolated due to circuit faults standards
or removed.
continue to communicate within the group . Bus and single path star topologies meet NFPA
Data is regenerated at each node with a minimum
. Supported communication media - 72 Class B, Style 4 signalling circuit standards
delay (1/2 bit time). This provides maximum
combinations of fibre optic, twisted/shielded . All equipment is UL listed (864) (UOJZ) for
distance between nodes and isolation of signalling
pair and twisted/unshielded pair NFPA 72 local, auxiliary, remote and propriety
circuits between nodes without impacting data
. Supported topologies - combinations of star, signalling services (UL File No. S2561)
throughput. Isolation ensures that a short/open
bus and ring connections . CSFM No. 7170-1493:167
condition on a circuit between any two nodes does
. Token passing non collision (deterministic) . MEA No. 415-92-E, Vol. VI
not affect other circuits.
communications protocol Product Codes
In the event that groups of nodes are isolated from
. Plug-in module (model TLI-530) connects 976165
the remainder of the network, due to one or more
equipment anywhere on the network TLI-530 Module kit for use on TFX-Net only
circuit faults, each group will automatically re-
Features - TFX Panel Operation 976166
configure communications and continue to inter-
. Up to 62 AUTOCALL TFX Series fire panels TLO-530 Board kit for use with TFX-Net
operate. When the fault condition is restored, the
connect to a single TFXnet network; Supports 976167
network will re-configure and total communications
up to 61,380 analogue addressable points; TLD-530 Board kit for use with TFX-Net
will commence.
4960 zones; over 7000 digital I/O points 976168
. Panels maintain full stand-alone functionality TLB-530 Baseboard for use with TFX-Net
. Each panel can be configured to respond to (Interconnecting cables are included)
events from all or any other sub-set (referred to
as sub-net) of other panels

End of Line Assembly


This unit is used with alarm signal circuits of main
processor.
Product Code
976016
TFX IAS-500 End of line (EOL) assembly

Page 19
tyco Fire & Tyco Electronic
Security Product Group
AUTOCALL CAA-500LI Module
6 circuit, this causes a shorted section between Listings & Approvals
two CAA-500LI modules to be isolated from the . UL File Number S374
rest of the loop. The AUTOCALL TFX panel . CSFM No. 7300-1493:152
indicates which devices in the loop have been . MEA No. 415-92-E Vol. VI
isolated, to assist in locating and correcting the . FM ID No. OX2A8.AY
short circuit condition. Once the short circuit has Technical Specification
been cleared, the CAA-500LI automatically resets, Dimensions: 112.5H x 112.5W x 25D mm
and communication with the isolated devices is Operating Temp.: 0oC to 50oC
restored. Operating Humidity: 85% (Non Condensing)
Features Operating Voltage: 28Vd.c. maximum
. Isolates short circuits on signalling circuit to Signalling Circuit Current:
The AUTOCALL CAA-500LI module is used only
prevent failure of entire circuit Standby Current: 0.7mA
with the AUTOCALL TFX fire control panels to
. Automatically resets on correction of short Alarm Current: 0.7mA
detect and isolate short circuits. This module
circuit Cover Material: Polycarbonate ABS Alloy
should be installed between groups of addressable
. Status LED indicates short circuit detection Product Code
devices to prevent failure of the entire signalling
. No external power required 976026
circuit loop in the event of a short circuit. Upon
. High EMF/RFI noise immunity TFX CAA-500LI Line isolator module complete
detection of a short circuit, this module opens up
. May be configured to meet NFPA style 7 with 2 gang mounting plate
the positive leg of the signalling circuit. On a Style
requirements

Addressable Contact Monitor Modules


status of its initiating circuit. The LED latches Features
steady on alarm. . Supervises and monitors dry contact devices
These modules may be programmed to report . Normally open and normally closed
inputs as either alarm or supervisory conditions. programmable options (IXA-500CMA)
Another programming option invokes a special . IXA-501CM Fits inside standard electrical box
polling interrupt routing, resulting in quicker alarm . IXA-500CMA Mounts on standard 2 gang
response than systems which rely on simple electrical box
polling techniques to detect an alarm. . High EMF/RFI noise immunity
IXA-500CMA . Powered directly by signalling circuit (no
The IXA-500CMA provides a Style B or D initiating additional power required)
circuit and mounts on a standard 2-gang electrical . Programmable for normal or fast (polling
The AUTOCALL contact monitor modules IXA-
box. An attractive plastic cover with eggshell finish interrupt) alarm reporting
500CMA (Style B & D)and IXA-501CM (mini
is included. An LED is visible through an opening Listings & Approvals
module) provide an initiating zone suitable for
in the plastic cover and illuminates steadily during . UL File No. S374
contact devices such as pull stations, waterflow
alarm. . CSFM No. 7300-1493:152
switches and sprinkler supervisory devices. Each
The IXA-500CMA may be programmed to monitor . MEA No. 415-92-E Vol. VI
module reports and input from any contact device
normally open or normally closed contact devices. . FM ID No. OX2A8.AY
in its zone as a single address to the AUTOCALL
IXA-501CM Product Codes
TFX series systems.
The IXA-501CM mini module provides a Style B 976081
Each contact monitor module uses one of 126
initiating circuit. Its compact size makes it ideal for TFX IXA-501CM Addressable mini contact module
available addresses on an AUTOCALL TFX
placement inside a standard electrical box behind 976092
signalling circuit. It responds to regular polls from
the monitored contact device, such as a TFX IXA-500CMA Addressable contact module
the control panel and reports its type and the
pullstation. complete with US double gang mounting plate
Technical Specification
IXA-500CMA IXA-501CM
Dimensions 122.5H x 122.5W x 25D mm 37.5H x 35W x 12.5D mm
Operating Temperature 0oC to 50oC 0oC to 50oC
Operating Humidity 85% (Non condensing) 85% (Non condensing)
Operating Voltage 28Vd.c. 28Vd.c.
Signalling Circuit Current:
Standby Current 0.18mA maximum 0.18mA maximum
Alarm Current 0.18mA maximum 0.18mA maximum
Initiating Circuit Wiring Resistance 10 Ohms maximum 10 Ohms maximum
Cover Material Polycarbonate ABS Alloy N/A

Addressable Detector Monitor Module


of its initiating circuit. This module contains bi- Operating Voltage:
coloured LEDs (red for alarm and yellow for fault). Signalling Circuit: 28Vd.c. Max.
Features External Power: 24Vd.c.
. Supervises and monitors two wire smoke and Signalling Circuit Current:
heat detectors Stand-by Current: 0.18mA
. Supervises 24Vd.c. detector power on two wire Alarm Current: 0.18mA
loop External 24Vd.c. Power:
. Resets detectors on command from control Stand-by Current: 18mA
panel Trouble Current: 26mA
. Style B and D initiating circuits Alarm Current: 74mA Max.
. Contains Bi-coloured LEDs to display alarm Initiating Current Voltage: 16.9 to 22.2Vd.c.
The AUTOCALL Addressable detector monitor
fault status Initiating Circuit Ripple Voltage: 500mV p-p Max.
module IXA-500DMA, provides an initiating zone
. High EMF/RFI noise immunity Initiating Circuit Wiring Resistance: 25 Ohms
suitable for compatible two wire smoke and heat
Listings & Approvals Cover Material: Polycarbonate ABS Alloy
detectors. Each module reports an input from any
. UL File No. S374 Product Code
detector in its initiating circuit as a single address
. CSFM No. 7300-1493:152 976093
to the AUTOCALL TFX series system. Up to 20
. MEA No. 415-92-E, Vol. 6 TFX IXA-500DMA Addressable detector zone
detectors can be connected to the initiating circuit,
. FM ID No. OX2A8.AY interface module complete with double gang. US
depending on the specific detectors used.
Technical Specification mounting plate
Each detector monitor module uses one of 126
Dimensions: 112.5H x 112.5W x 25D mm
available addresses on an AUTOCALL TFX
Operating Temp.: 0 to +50oC
signalling circuit. It responds to regular polls from Operating Humidity: 85% Non-Condensing
the control panel and reports its type and the state
Page 20
tyco Fire & Tyco Electronic
Security Product Group
OXA-502RM - Addressable Relay Module
Each relay monitor module uses one of 126 Listings & Approvals
available addresses on the AUTOCALL TFX . UL Listed: File No. S2561
signalling circuit. It responds to regular polls from . CSFM No. 7300-1493:152
the control panel and reports its type and status. A . MEA No. 415-92-E Vol. VI
flashing LED indicates that the module is in . FM ID No. OB2A9.AY
communication with the control panel. Up to 99 Technical Specification
modules can be placed on an individual circuit. Dimensions: 113H x 113W x 33D mm
The OXA-502RM is an addressable field module Operating Temp.: 0oC to +50oC
and is provided with an attractive plastic cover with Operating Humidity: 85% (Non Condensing)
eggshell finish. The status LED is visible through Relay Contact Rating: 2A @ 24Vd.c, 0.6A @
the plastic cover. 120Va.c.
The AUTOCALL OXA-502RM module provides a Features Addressable Loop Current:
form C relay contact for annunciation and auxiliary . Provides one Form C programmable relay Standby Current: 0.18mA
control purposes with the AUTOCALL TFX series contact Alarm Current: 0.18mA
fire alarm systems. Both are monitored and . Monitored and controlled from a signalling line Cover Material: Polycarbonate ABS alloy
controlled as an addressable device on an circuit (addressable loop) Product Code
AUTOCALL TFX system signalling line circuit. The . Powered by signalling line circuit. No external 976258
relay contact may be programmed to operate in power TFX OXA-502RM Addressable relay module
conjunction with any single or group of input . LED indicates relay operation complete with US double gang mounting plate
events. . High EMF/RFI noise immunity

Multi Detector Monitor Module


individually addressable. Listings & Approvals
The module is compatible with 2-wire or 4-wire, UL . UL Listed; File No. S2561
listed, low voltage, conventional, point type . CSFM No. 7165-1493:147
detectors or normally open contact initiating 7170-1493:167
devices. Up to 30 detectors may be connected to 7300-1493:152
each initiating circuit, depending upon the specific . MEA No. 415-92-E, Vol. IX
detector used. Product Codes
The Multi Detector Monitor Module (MDM521) Each zone on the MDM521 has a latching, red 976375
connects zones of conventional 24Vd.c. detectors LED to provide indication of an alarm condition. TFX MDM/521 Addressable multi way
and interfaces them to the AUTOCALL TFX series Resettable 24Vd.c. is provided for using four wire conventional detection zone interface for 1-8
fire alarm systems. The MDM521 provides eight detectors. zones
Style B, Class B zones. Features 976399
The Multi Detector Monitor Module fully monitors . Supervises and monitors two-wire or 4-wire TFX MDM Mounting plate
each initiating circuit of conventional 24Vd.c. smoke detectors
detectors and signals the control panel upon . Resets detectors on command from control
alarm, open circuit fault, or power supply fault. panel
Each zone reports as a single address to the . Eight Style B initiating circuits
AUTOCALL TFX series control panel, however, . Contains LEDs to display alarm status
the detectors in these conventional zones are not . Mounting plate accommodates two MDM521s
and one mini module

Notification Appliance Module


The 506SDA is an addressable field module and is Addressable Loop Current:
provided with an attractive plastic cover with egg- Standby Current: 0.35mA
shell finish. An LED is visible through an opening Alarm Current: 0.35mA
in the plastic cover. External 24Vd.c. Power: Any UL listed supply,
Features compatible with the connected notification
. Provides a Style Y or Style Z, audio or d.c., appliances
notification appliance circuit Standby Current: 0.08mA
. LED annunciation at each device for normal, Alarm Current: 0.08mA
activated and trouble conditions (Plus current used by connected
. Supervises 24Vd.c. appliance power without notification appliances)
976378 the need for a supervisory relay Cover Material: Polycarbonate ABS Alloy
. 2 Amp output rating Product Codes
The AUTOCALL 506SDA notification appliance . Silenceable and non-silenceable operation 976378
modules are used to activate notification . High EMF/RFI noise immunity TFX 506SDA Addressable sounder/notification
appliances in response to a command sent from . Will not operate into a short circuit fault device output module complete with US double
the fire control panel. . Plug-in power limiting option gang mounting plate. Used for switching sounder
The 506SDA works in conjunction with the Listing & Approvals and speaker circuits
AUTOCALL TFX series fire alarm systems, and . UL Category UOXX, File No. S374 976250
CONSYS Issue 3.0 and above. . CSFM No. 7165-1493:147 Spare TFX 27K 1W Resistors for use with
The notification appliance circuit is supervised and 7300-1493:152 505/6SDA
may be configured as an NFPA 72 Style Z or Style 7170-1493:167 910683
Y circuit. The AUTOCALL 506SDA may be . MEA No. 415-92-E Vol. XI TFX Spare dual voltage RPS-424 power
powered from either an audio source or a separate Technical Specification supply/charger used on all TFX panels
power supply that is UL listed for fire signalling Dimensions: 112.5H x 112.5W x 31D mm
applications. Operating Temp.: 0 to +50oC
When the 506SDA is used with the UL listed RPS- Operating Humidity: 85% Non-Condensing
424 power supply (910683), or any other power Notification Circuit Rating:
limited input source that is UL listed for fire 2.0Amp Max., 24Vd.c.
signalling applications, the output is power limited. 50 Watts, 25VRMS audio
The 506SDA will not operate into a short circuit 50 Watts, 70VRMS audio
fault condition. This ensures the operation of all
other devices during an alarm condition including
other 506SDAs.

Page 21
tyco Fire & Tyco Electronic
Security Product Group
Pullstations & Ancillaries
Hazardous Locations Technical Specification
The RMS series explosion proof, weather proof Dimensions: 118H x 83W x 37D mm
pull stations are constructed of high strength metal (RMS-1T)
die cast alloy. 118H x 81W x 43D mm
The UL rating of Class I Group B (Hydrogen) C & (RMS-1T WP-LP)
D, Class II Groups E, F, G, Class III and outdoor Weight: 560g (RMS-1T)
rating of type 4X, allows these stations to offer 909g (RMS-1T WP-LP)
unmatched placement flexibility. The terminal Contact: Single pole, single throw
block connections, D.P.D.T contacts @ 10 amps (double pole, single throw
meet most electrical requirements indoors and out. optional)
Having a ‘conventional’ pull station design the Contact Rating: 10 Amps @ 125/250Va.c.
RMS series stations offer easy identification. Wire AWG: 12 to 22 AWG
Features Wiring: Terminal block connections
The RMS series manual pull stations are of high . Die cast metal construction (6-32 w/sem plate)
quality non-toxic die-cast construction. . Low profile functional design Switch: 10 Amp @ 120Va.c.
Low profile and smooth edges offer an attractive . Dual action option Key Switch: (pre-signal) 0.5 Amp 30Vd.c.
yet functional design. All components are pre- . Institutional (Key operated) option Product Codes
painted or have plated surfaces to inhibit . Explosion proof option 960673
corrosion. . Break glass option TFX RMS-1T Single action non addressable pull
The RMS series manual pullstations have a 10 . Weatherproof option station
amp snap action switch. They can be used with or . Hex screw or key lock reset options 960678
without a break glass rod for positive indication . UL Listed TFX RMS-1T WP-LP Dual action weatherproof
that the unit has been operated. pullstation

Addressable Manual Stations


painted or have plated surfaces to inhibit reporting
corrosion. . Optional dual action
The RMS series manual pull stations have a 10A . Optional break glass
snap action switch. All stations can be used with or . Optional hex screw or key lock reset
without a breakglass rod (included) for positive Listings & Approvals
indication that the unit has been operated. . UL Listed; File No. S165
AUTOCALL TFX series programming with . CSFM No. 7150-1493-156
CONSYS allows an addressable manual station to Technical Specification
be automatically programmed for “fast response” Dimensions: 118.75H x 80W x 22D mm
that invokes a special polling interrupt routine. This Wire AWG: 12 to 22 AWG
results in a one second alarm response. Systems Wiring: Terminal block connections
The AUTOCALL IXA-RMS series manual
which rely on simple polling techniques to detect Product Codes
pullstations are of high quality, non toxic, diecast
an alarm can take longer to report manual alarms. 976277
construction and connect directly to AUTOCALL
Features TFX IXA-RMS Addressable indoor pullstation for
TFX series systems. Using one of 126 available
. Die cast metal construction use on TFX panels
addresses on the loop, each station responds to
. Low profile functional design 960687
regular polls from the control panel and reports its
. Terminals for field wiring TFX Surface mount backbox for use with RMS
type and status.
. Powered directly by signalling circuit (no pullstations
Low profile and smooth edges offer an attractive
additional power required) 960684
yet functional design. All components are pre
. Programmable for normal or fast alarm TFX Spare glass rod for use with RMS pullstations

Notification Appliances - Motor Types


steel gongs. These alarm bells can be mounted in Product Codes
standard outlet boxes or 4” x 4” junction boxes. All 508722
are specifically designed for use with fire alarm K-MP-6P 6” UL Bell 30mA 85dB
systems and are UL listed. 508723
UL Spherical dB Measurement K-MB-8P 8” UL Bell 30mA 85dB
Sound level measurements are made in 508724
accordance with UL Test Standard 464. The K-MB-10P 10” UL Bell 30mA 85dB
audible device is wall mounted in a reverberant
room and sound power output is measured at
508722 various points along a 10’ radium from the wall
(i.e. the spherical dB measurement represents an
These alarm bells are ideal warning devices for
average of several readings taken along a 180 arc,
schools, stores, public buildings and any other
10 feet from the bell.
location with low to moderate ambient noise levels.
Indoor Measurement
These alarm bells come in six, eight and ten inch
Sound level in the indoor installation may vary
sizes and are all completely enclosed in an
depending upon room size and acoustical loading.
aluminium die cast housing with red enamelled
Technical Specification
Product Code Vibrating Type Rated Size (Inches) Rated Current Starting Voltage UL Spherical dB Indoor Measurement
Voltage Polarised Measurement
508722 24Vd.c. 6 0.03A 12V 84 86-89
508723 24Vd.c. 8 0.03A 12V 87 90-93
508724 24Vd.c. 10 0.03A 12V 87 92-94

Page 22
tyco Fire & Tyco Electronic
Security Product Group
Releasing Equipment
Technical Specification
Dimensions:
GARA-1: 128H x 175W x 51.5D mm
GAR-1 118.75H x 84W x 51.5D mm
Operating Temp.: 0 to +50oC
Operating Humidity: 85% Non-Condensing
Terminal Block Wiring:No. 12AWG shielded (Max.)
Current Requirements:
GARA-1: 0.0mA Supervisory;13mA
Alarm
GAR-1: 0.0mA Supervisory; 0mA
GARA-1 GAR-1 Alarm
Product Codes
The AUTOCALL GARA-1 and GAR-1 fire Features 976376
suppression agent releasing stations are suited for . Releasing station constructed of die-cast metal TFX GARA-1 Addressable gas agent releasing
use wherever releasing or pre-action deluge . Low profile functional design and abort module
applications are required. . Dual action 976381
The GARA-1 and GAR-1 fire suppression agent GARA-1 Additional Features TFX GAR-1 Addressable gas agent releasing
releasing stations use normally open contacts. The . Abort switch station
stations operate and reset easily, and may be . System activated indication 976413
semi-flush or surface mounted. . System normal indication TFX505SDA/RM Panel mounting addressable gas
The GARA-1 includes an abort switch as well as a Listings & Approvals release solenoid control kit
“system normal” LED. . UL Category UOXX, File No. S374. UL Listed 976414
Both fire suppression agent releasing stations are for fire alarm and releasing service TFX 506SDA/RM Addressable gas release
compatible with the AUTOCALL TFX series fire . MEA No. 415-92-E, Vol. IX solenoid control kit for installation remote from the
alarm systems. The stations are also compatible . CSFM No. 7165-1493:147 panel
for use with all UL listed solenoids used in 7300-1493:152
sprinkler systems, when used in conjunction with 7170-1493:167
the 505SDA/RM (976414) or 506SDA/RM
(976413) agent releasing kits and the RPS-424
power supply/ battery charger (910683).

Page 23
tyco Fire & Tyco Electronic
Security Product Group
Conventional Fire Alarm Panels - BS5839 and EN54
MINERVA 1-4 Conventional Fire Controllers
performance and minimum lifetime costs. Quiescent Current: 90mA plus 10mA per zone
Particular attention has been paid to the Alarm Current: 150mA plus 100mA per
appearance of this unit, recognising that in many zone
installations the control panel may be on display in
Operating Temp.: -10ºC to +55ºC
a reception area.
Relative Humidity: up to 95% non-condensing
The controller has been designed to prEN54 pt 2
& 4 and approved to BS 5839 part 4. IP Rating: IP33
The design and manufacturing facilities of ADT Material: Polycarbonate/ABS Alloy
Fire & Security are ISO9001/BS 5750 accredited. Branding: Supplied with multiple Tyco
Features branding
. Available in 1, 2 or 4 zones Product Code Language Zones
. LPCB approved to BS 5839 Pt 4 -1988 508.018.001 ADT(UK) 1
. Integral charger and batteries 508.018.002 ADT(UK) 2
. Simple LED display and push-button operator
508.018.004 ADT(UK) 4
controls
. One man walk test facility enables easy 508.018.012 Dutch 2
commissioning and maintenance with 508.018.014 Dutch 4
minimum disruption 508.018.021 English 1
. Zone disable function for each zone via front 508.018.022 English 2
panel
. May be used with BASEEFA Approved 508.018.024 English 4
Intrinsically Safe System 601 508.018.031 Arabic 1
. Two sounder circuits with sounder delay 508.018.032 Arabic 2
options 508.018.034 Arabic 4
. Non-latching alarm input
. Remote fault input, class change input
. Earth fault monitoring MINERVA 1-4 Ancillaries
. Cross-zoning facility available 509.018.001
. Optional alert/evacuate facility enables
Conventional MINERVA Battery Clamp For Use
callpoints to generate an evacuate alarm and
With All 1-4 Zone Controllers
The MINERVA 1,2 and 4 zone conventional detectors an alert warning
509.018.002
controller has been engineered to bring a high
quality, low cost, LPCB Approved unit to the Technical Specification Conventional MINERVA Semi-Recessed Mounting
market-place without compromising the features Bezel Kit For Use With All 1-4 Zone Controllers
Dimensions: 290H x 340W x 90D mm
offered to the client. 509.018.010
Weight: 3.7Kg (without batteries)
Ideally suited to offices, shop units, small guest Gland Cover To Hide Cable Entry To 1-4 Zone
Power Supply: 220/240Va.c. +/- 10%
houses and manufacturing/warehouse units, it Controller
may also be used as a local controller as part of 50/60Hz
509.018.006
an integrated system in areas such as shopping Maximum Battery: 7Ah
Active EOL Device
malls or computer suites. Sounder Circuits: 2 x 500mA @ 24Vd.c.
517.050.007
Advanced design and manufacturing techniques, Alarm/Fault/Zone relays: 1A @ 24Vd.c.
M600D Continuity diode base
including a powerful custom ASIC microchip and Zone Voltage: 21.3V nominal
surface-mount printed circuit boards combine to Minerva 1-4 Spares
Internal Charger: 3.3A @ 32.5V
offer a simple and reliable controller with optimum 509.018.101
PSU for 1 zone (spare)
MINERVA Conventional Schematic 509.018.102
PSU for 2 zone (spare)
509.018.104
Non PSU for 4 zone (spare)
Remote latching Class
alarm change 509.018.105
fault
Control PCB 1 Zone (spare)
509.018.106
2 monitored
sounder circuits Control PCB 2 Zone (spare)
509.018.103
Alarm Control PCB 4 Zone (spare)
output MINERVA
Fault CONVENTIONAL Datasheet - Product Code PSF72 “Minerva 1, 2 &
output 4 Zone Panel”
CONTROL
Field supply Manual - Vol04A-01-D1 “Minerva 1-4 Zone
Zonal UNIT
Conventional Fire Controller Manual”
output(s)

EOL Device (509.018.006)

1, 2 or 4
detector
M300/600 Series Detector circuits

Page 24
tyco Fire & Tyco Electronic
Security Product Group
XL100 Fire Detection Control Panels
General Wiring Diagram

The range of XL100 Fire Detection Control Panels


provide an excellent low cost solution for
conventional fire detection systems with up to 2,4
or 8 zones of detection. Each detection zone can
support up to 24 conventional detectors or an
unlimited number of callpoints. The XL100 panel
supports many manufacturers conventional
detectors and has been fully tested with the M601
LPCB approved and M613 VdS approved ranges
of Tyco low profile detectors.
Each version of the panel provides detection zone
monitoring and sounder output monitoring.
Detection zones are monitored for detector
removal as well as open and short circuit fault
conditions.
Zone 1 can be configured as a non-latching shop
interface to allow adjacent panels to override the
panel into Alert or Evacuate mode. A non-latching
normally open auxiliary input allows a remote
evacuate or remote sounder activation (class Features Product Codes
change) to be signalled to the panel. • Low cost 2, 4 or 8 zone system 508.021.002
• State of the art aesthetic design
The panel also provides common fault and XL102 2 Zone Conventional Controller
• Compatible with Vds & LPCB Approved Lo-Pro
common fire, single pole changeover relay outputs 508.021.004
detector range
rated 1A @ 24Vd.c.The common fault relay is
• Compatible with MU601 CO Fire detectors XL104 4 Zone Conventional Controller
normally energised and de-energises to signal any
• Class change, remote evacuation and shop 508.021.008
zone fault, processor fault, mains failure, battery
interface options
fault, earth fault and supervised output fault. The XL108 8 Zone Conventional Controller
• Detector removal monitoring
common fire relay is normally de-energised and XL100 Spares & Ancillaries
• One man walk test facility
energises to signal any zone fire or evacuation
• Zone isolate capability 509.021.001
alarm condition.
• Up to 7 Ah internal battery capacity XL100 Spare Commissioning Kit
Each XL100 panel has an integral 24Vd.c. 2A • Designed to comply with BS5839 Pt. 4
rated power supply. The panels have 2 x 750mA (Included with all XL Panels)
• EMC Compliant to EN50082-1, prEN50093,
rated separately fused sounder circuits and a 24V IEC801-3 & EN550022 509.021.011
500mA rated fused auxiliary supply. The total XL100 Spare PSU for XL102/4/8
power available for sounder circuits and the
Technical Specification 509.021.012
auxiliary supply is 1.5A. The remaining 500mA is
sufficient to provide power to 8 fully loaded M600 Mains Supply: 198 to 264Va.c.45 to 66Hz XL100 Spare Main PCB for XL102/4/8
detection circuits and the panel electronics when 250mA Maximum
in alarm condition. Charger Output: 24Vd.c. 2A Maximum Datasheet - Product Code PSF93 “XL100 Fire
The XL100 panel has sufficient space internally Sounder Outputs: 24Vd.c. @ 750mA (x2) Control Panels”
for two 12V 7Ah batteries which can provide up to Auxiliary Supply: 24Vd.c. @ 500mA
72 hours standby power and 30 minutes in alarm,
Maximum Output: Sounder Outputs + Aux.
even on a fully loaded 8 zone XL108. In order to
Supply not to exceed 1.5A
comply with BS5839Pt1 the XL100 charger can
recharge the batteries sufficiently with 24 hours to Battery Rating: 7Ah maximum
provide a further 72 hours standby and 30 Recharge time: 24 hrs recharge 7Ah to 85%
minutes alarm current. Dimensions: 240 H x 322 W x 115 D mm
The XL100 panel fully complies with BS5839pt4 Weight: 2Kg excluding batteries
including zone isolate and sounder disable
Operating Temp: 0 to +40°C
functions.
Humidity: 0 to 90% RH (non
The panel is designed to facilitate a quick and
condensing)
neat installation. Premoulded 20mm cable gland
entries are provided from the top, bottom and rear EMC/RFI: Tested to EN50082-1,
and a removable hinged lid provides easy access prEN50093, IEC801-3 Level
during installation. The panel can be surface or 2 & BS EN550022
semi-flush mounted. Branding: Supplied with multiple Tyco
branding labels

Page 25
tyco Fire & Tyco Electronic
Security Product Group
System 1700
A uniquely flexible series of basic fire controllers. Conventional style monitored detector zones, • Selective sounder operation
Covering 4 or more zones of fire detection and each consisting of up to 20 standard smoke heat • All circuits fault monitored
suitable for cost effective protection in a wide detectors or callpoints. • Remote signalling output
range of building types. Detection, display, alarm, Remote display or control are driven by a • Designed for fire alarm systems specified to
and extinguishing control, can be tailored to meet multiplex transmitter/receiver system on a single BS5839: Part 1:1988
any need. pair cable. Each transmitter can feed up to 4 • Proven exceptionally reliable world-wide
Technical Information receivers, at a distance of up to 1Km. Display
legends are replaceable. Standard legend is Datasheet - Product Code PSF41 “System 1700
System 1700 consists of 14 standard modules,
English or on the reverse Arabic/English, but Conventional Fire Controller”
selectively assembled in one of 5 housings which
can be flush mounted using the appropriate kit - to blanks are available to suit other customer Manual - FD-1.1.31.02 “Fire Detection Manual”
meet any specific customer requirement within the requirements.
designed capacity. These units can be configured Features
to provide fire detection with local display, remote • Expandable in four zone increments
display, extinguishing control or any combination • Customised by module selection - uniquely
of these functions with integral power units and flexible
secondary batteries or from separate 24Vd.c. • Integral battery and charger
power supplies. Alarm sounder outputs can be • Simple controls
commoned or pre-programmed for specific • Local and remote displays
building sectors. • Easy installation and extension

Alarm Module with Display


Alarm Module with Display is the central control
unit driving the sounders and auxiliaries. The
display indicates Power On, Fire or Fault, and has
push-button switches for Evacuate, Silence, Reset
and Lamp Test enabled by a key-switch. The
module also has the integral sounder.
Product Codes
508.014.020
1700 Alarm PCB & Display (see picture)
508.014.050
1700 Alarm Unit Display Dutch TNO
508.014.055
System 1700 Spare Key

Integral Power Modules


There are two versions available:- 1.5A or 3.0A Product Codes
suitable for powering the system and recharging 508.014.032
integral sealed lead-acid batteries. The power
1700 1.5 Amp 240V PSU
modules are available to suit 110Va.c. or 240Va.c.
mains supply. 508.014.033
1700 3 Amp 240V PSU
508.014.036
1700 1.5 Amp 115V PSU
508.014.037
1700 3 Amp 115V PSU

External Power Interface Module


Fitted internally and monitors a suitable 24Vd.c.
supply. The module monitors the external power
supply for any fault condition signalled. The
module should be used with an external power
supply when Nickel-Cadmium batteries are
specified.
Product Code
508.014.031
1700 External Power Interface PCB

Page 26
tyco Fire & Tyco Electronic
Security Product Group
Four or Eight Zone Module with Display
Provides the power to each detection zone which
respond to four conditions, open-circuit fault,
quiescent, alarm or short-circuit fault. Individual
indication is given for either Alarm or Fault. Each
zone has a corresponding output which is
energised in an alarm condition and is suitable for
driving zonal relays and/or auxiliary modules i.e.
multiplexed repeater.

508.014.023 508.014.024
1700 4 Zone PCB & Display 1700 8 Zone PCB & Display

Multiple Output Module


Allows a single output or groups of outputs to be
activated in response to a single input. The
module provides up to 16 outputs with 8 inputs, or
conversely each module can provide up to 8
outputs with 16 inputs.
Product Code
508.014.049
1700 Multiple Output Module PCB

Relay Module
Mounted internally and has 4 heavy duty relays
each with a single changeover contact (rated 5A
@ 30Vd.c.). The relays are normally energised
from the individual zone outputs of the zone
module.
Product Code
508.014.028
1700 Relay PCB

Sector Sounder Module


Allows up to 4 groups of sounders to be activated
in a pre-programmed response from up to 10
zones of detection. Each group can be
programmed to respond in either pulsing or
continuous output. Each output is fused 1A
@24Vd.c.
Product Code
508.014.026
1700 Sector Sounder PCB

Sounder Booster Module


Allows for extra power to be supplied to a sounder
circuit. It is normally used when large numbers of
sounders are required in one circuit or where long
distances create volt-drop problems. Additional
current is 1.5A.
Product Code
508.014.027
1700 Sounder Extension PCB

Page 27
tyco Fire & Tyco Electronic
Security Product Group
Multiplex Transmitter Module
Transmits up to 16 independent signals plus
common alarm or fault to up to 4 multiplex
receiver modules at remote locations over a pair
of signal wires (max. length 1 Km).
Product Code
508.014.029
1700 Multiplex TX PCB

Multiplex Receiver Module


Receives and encodes the signals from a
multiplex transmitter module. The outputs can be
used to drive either a Repeater display module,
Mimic indicators etc.
Product Code
508.014.030
1700 Multiplex RX PCB

Repeater Display Module


Displays the information from the Multiplex
receiver module. The Remote Alarm display
provides indication of Fire, Fault, and Power On
together with Silence and Lamp Test facilities. The
Repeater Display module provides up to 16 Fire
indications.
Product Codes
508.014.021
1700 Alarm Repeater Display
508.014.022
1700 16 Zone Repeater Display

Extinguishing Module and Display


Provides for complete control of a gaseous
extinguishing system. The input commands are
taken from the coincident zonal outputs. The
module also has an independent Manual Release
facility and has indicators for Manual-Automatic
mode, Gas Released and Disabled conditions
together with a key switch for mode selection. The
module has facilities for extensive electrical fault
monitoring, cylinder pressure monitoring, and an
adjustable time-delay before gas release.

508.014.043.A 508.014.025
1700 Extinguishing Module Mounted In A Single 1700 Extinguishing Control PCB and Display
Aperture Housing ADT Branded (shown)
508.014.043.T
1700 Extinguishing Module Mounted In A Single
Aperture Housing Thorn Security Branded

Page 28
tyco Fire & Tyco Electronic
Security Product Group
Coincidence Module
Designed to activate one or both relays in
response to an alarm condition from up to eight
zonal outputs. This module is primarily used in
conjunction with the extinguishing module, but
may also be used for other applications.
Product Code
508.014.048
1700 Coincidence Module PCB

Housings
Technical Specification
Dimensions (mm) Weight Display
ADT Thorn Bezel Kit Housing Height Width Depth (Kg) Capacity Module Space
508.014.011.A 508.014.011.T 508.014.012 2 Aperture 354 336 133 5 2H 2
508.014.013.A 508.014.013.T 508.014.014 3 Aperture 354 420 193 7 1V + 2H 4
508.014.015.A 508.014.015.T 508.014.016 5 Aperture 354 637 193 9.5 1V + 4H 6
508.014.039.A 508.014.039.T 508.014.040 8 Aperture 760 531 233 14.5 8H 10
508.014.041.A 508.014.041.T 508.014.042 12 Aperture 1050 700 235 30 12H 18
H = Horizontal V= Vertical
As standard the System 1700 enclosures are Housing Accessories 1700 Battery Clamp Kits
available with Thorn or ADT Branding. A bezel kit 508.014.019 508.014.052
is available for flush mounting the panels
1700 Aperture Blanking Plate 1700 Battery Clamp Kit For 17Ah Batteries
Product Codes
508.014.034 508.014.053
508.014.047
1700 Custom Legend Strips Zones 33-64 1700 Battery Clamp Kit For 10Ah Batteries
1700 Installation Kit For 3 Aperture Housing English/Arabic 508.014.054
508.014.038 508.014.035 1700 Battery Clamp Kit For 7Ah Batteries
1700 Installation Kit For 5 Aperture Housing 1700 Custom Legend Strips, Blank System See Also Extinguishing Options

508.014.011.A 508.014.013.A 508.014.015.A


1700 2 Aperture 1700 3 Aperture 1700 5 Aperture

508.014.039.A 508.014.041.A
1700 8 Aperture 1700 12 Aperture

Page 29
tyco Fire & Tyco Electronic
Security Product Group
NT100 Conventional Controllers
Standard Fire Control PanelStandard Fire Repeater Panel
Country NT108 NT116 NT116R
U.K. 508.022.008 508.022.016 508.022.038
Spain 508.022.007 508.022.019 508.022.039
Belgium 508.022.009 508.022.017 508.022.044
Holland 508.022.010 508.022.018 508.022.045
Fire Panels with Integral Fireman’s Interface
Country NTF08 NTF16
Finland 508.022.011 508.022.029
Denmark 508.022.014 508.022.032
Norway 508.022.012 508.022.030
Sweden 508.022.013 508.022.031
Holland 508.022.042 508.022.043
The range of NT100 panels are state-of-the-art Product Codes Anciliaries
intelligent fire panels, which provide many of the
The following product codes include all the 509.022.014
features normally only found on more expensive
optional extras which can be included as part of NT 3 Metre -Cable Assembly For Connection Of
analogue addressable panels. The range of
your customer's requirements. Additional spare NTX-01 To NTX-02/3/4 Typically Used For
control panels are LPCB approved to EN54Pt. 2
parts are also included. Connection To Remote NTX-02 Relay Unit
and 4 and include many local approval authorities
around the world. The panels are supplied in 8 509.022.001 509.022.XXX (See Note 1)
and 16 zone versions. Each detection zone can NT100 Series Spare Commissioning Kit NT/NTR/NTF CPU Board V1.7 Spare
support up to 32 conventional detectors. The user Included With All Panels 509.022.031
interface is provided through a combination of
509.022.008 NTF Fireman’s Interface PCB Spare
LEDs and a 2 x 40 character LCD display. The
LCD display provides a full customer definable PRN-02 Spare Printer Paper For PRN-01 509.022.032
text display of the alarm or fault condition whilst (Supplied In Packs Of 5 Rolls)
NTR Release User Interface PCB Spare
also displaying zones in alarm, fault or isolate 509.022.009
509.022.033
status. The display also indicates the outputs that PRN-03 Spare Printer Ribbon For PRN-01
have been activated. Each control panel can have NT/NTR/NTF Display PCB Spare
509.022.011
up to a maximum of 3 repeaters. 509.022.034
NT100 Spare PSU For NT,NTR & NTF Variants
Features NT PSU Plug In Fuse 2 (Pack Of 10)
509.022.012
• LPCB & ANPI (BOSEC) approved to EN54
Parts 2 and 4 Bulkhead Mounting Kit
NOTE 1: All NT Panels now use one version of
• Customer friendly, multi language information 509.022.013 main CPU core software (V1.7). Product Code not
on LCD display NT Flush Mount Bezel NT-I/O Expansion available at time of going to press.
• Comprehensive fault diagnostics
• 8 and 16 zone Panels General Wiring Diagram
• Can be used with a wide range of approved
detectors
• Detector removal monitoring
• 4 monitored Sounder outputs up to 4A
• 4 monitored Relay outputs
• 3 programmable auxiliary inputs
• 3 levels of alarm discriminations per zone
• One common fault relay
• Internal batteries (up to 12Ah)
• Programmable cause and effect
• Programmable user access levels
• Can interface to intrinsically safe System 601
• Manned/ unmanned mode
• Optional fireman's interface
• Optional printer
• Optional repeater units
• Optional I/O expansion board
• 16 digital outputs or 16 relay output options
Technical Specification
Dimensions 320H x 430W x150D mm
Weight 6.3kg
Power Supply 198 -264Va.c.
Quiescent Current 50mA @ 24Vd.c.
Alarm Current 1Amp @ 24Vd.c.
Operating Temp 0 to +40°C
Operating Humidity 0-90% RH non-condensing

Datasheet - Product Code PSF95 “NT Fire Control


Panels”

Page 30
tyco Fire & Tyco Electronic
Security Product Group

509.022.004 509.022.005
509.022.007
NTX-02 16 Way Relay Output Board NTX-03 16 Way Digital Output Driver Board -
PRN-01 Optional Integral Printer for use with NT &
(24Vd.c.@1A) Requires NTX-01 Expansion Board Requires NTX-01 Expansion Board
NTF Controller Variants

509.022.003 509.022.006
NTX-01 4 Way Expansion Board - Supplied Fitted NTX-04 16 Way Digital Input Board for use on
to the NTF And NTR Controllers. Also Supports Special NT Controller Variants only
NTX-02,03,04 Expansion Boards

NTR100 Conventional Extinguishing Controllers


definable text display of the alarm or fault Technical Specification
condition whilst also displaying zones in alarm, Dimensions 320H x 430W x 150D mm
fault or isolate status. The display also indicates
Weight 6.3kg
the outputs that have been activated.
Power Supply 198 -264Va.c.
Features
Quiescent Current 50mA @ 24Vd.c.
• ANPI (BOSEC) Approved
• Customer friendly, multi language information Alarm Current 1Amp @ 24Vd.c.
on LCD display Operating Temp 0 to +40°C
• Comprehensive fault diagnostics Operating Humidity 0-90% RH non-condensing
• Manual release zone - direct to stage 2
Note: The NTR is compatible with the T500 range
• Can be used with a wide range of approved
of ancillaries.
detectors
• Detector removal monitoring
• 2 monitored Sounder outputs up to 4A Product Codes
• 2 monitored Solenoid circuits NTR-08 NTR-16
The range of NTR gas release panels are state- • 4 monitored Relay outputs Single Area Dual Area
of-the-art intelligent panels, which enables a wide • 3 programmable auxiliary inputs UK 508.022.003 -
variety of gas release applications to be • 3 levels of alarm discriminations per zone Belgian 508.022.004 -
implemented. The panel is provided with default • One common fault relay
settings to suit most INERGEN®, FM200™ and • Internal batteries (up to 12Ah) Dutch 508.022.005 508.022.021
CO2 applications and can be programmed to suit • Programmable cause and effect Danish - 508.022.025
most other gas releasing applications. For • Programmable user access levels Finnish 508.022.001 508.022.022
compatibility with latest standards the panel • Can interface to intrinsically safe System 601 Norwegian - 508.022.023
complies with all relevant parts of EN54 part 2 • High and Low pressure monitoring
• Initial/Reserve changeover facility Swedish 508.022.002 508.022.024
and 4. The NTR panel is designed to comply with
BS7273 and can be installed to fully comply with • Optional Door Interlock
• Optional remote hold and abort Datasheet - Product Code PSF106 “NTR
BS5839 Pt 1 and BS6266.
• Optional Auto/Manual key switches Intelligent Release Panels”
System Operation (Default UK Operation)
• Optional I/O expansion board
Stage 1 - The panel stays in Stage1 Fire Alarm
• 16 digital outputs or 16 relay output options
until the fire or false alarm source is removed and
the panel is reset or Stage 2 ensues. Product Codes 509.022.009
Stage 2 - The panel stays in Stage 2 for 30 The following product codes include all the PRN-03 Spare Printer Ribbon For PRN-01
seconds (adjustable) to provide a Pre-release optional extras which can be included as part of 509.022.011
Warning during which time the HOLD or ABORT your customer's requirements. Additional spare
NT100 Spare PSU For NT,NTR & NTF Variants
sequences can be initiated. parts are also included.
509.022.012
Stage 3 - The panel remains in Stage 3 Gas 509.022.001
Release for the solenoid firing time or until the Bulkhead Mounting Kit
NT100 Series Spare Commissioning Kit Included
release confirmation is received from the High With All Panels 509.022.013
Pressure Switch. 509.022.007 NT Flush Mount Bezel
Stage 4 - The panel remains in Fire Alarm PRN-01 Optional Integral Printer For Use With All 509.022.032
condition and indicates the gas released message NT Controller Variants NTR Release User Interface PCB Spare
until the system is silenced and reset. Failure to
509.022.008 509.022.033
receive a release confirmation will initiate a fault.
PRN-02 Spare Printer Paper For PRN-01 NT/NTR/NTF Display PCB Spare
The user interface is provided through a
combination of LEDs and a 2 x 40 character LCD supplied in Packs of 5 Rolls 509.022.034
display. The LCD display provides a full customer NT PSU Plug In Fuse 2 (Pack of 10)

Page 31
tyco Fire & Tyco Electronic
Security Product Group
NTR - Typical Wiring Schematic for Single Area Panels

Typical Extinguishing Gas Release Applications


Extinguishant Schematic Configuration with Extinguishant Solenoid Extinguishant Schematic Configuration with Pilot Container Solenoid

Extinguishant Initial/Reserve Schematic with Pilot Container Solenoid Extinguishant Initial/Reserve Schematic with Extinguishant Solenoid

Page 32
tyco Fire & Tyco Electronic
Security Product Group
T530 Extinguishing Release & Detection Panel
and monitoring of all output relays, lamps and Alarm Current: 420mA plus 70mA per zone
externally connected devices. Detectors can be in alarm and 150mA when
installed to give either a gated (delayed) or extinguishing control active
immediate response. Coincident operation in the Dimensions: 270H x 400W x 190D mm
automatic mode will initiate the gas release cycle;
Weight: 11.5kg
distinctive sounders give a pre-discharge warning
and any air-handling plant can be automatically Operating Temp: -10 to +55oC (Storage -20
switched off. After a time delay the gas release to +65oC)
mechanism is operated. Humidity: up to 95% RH non-
Features condensing
• Dual path circuitry to prevent a single fault dis- EMC/RFI: CE marked
charging gas Product Codes
• Microprocessor controlled for system integrity 508.013.036.A
The T530 is designed to control an automatic fire • Bright, clear display provides vital status infor-
T530 4 Zone Fire Detection and Extinguishing
detection system and in conjunction with its mation
Control Panel - ADT branded
associated range of ancillary equipment, will • Simple user controls reduce operator error
provide complete control of a gaseous • Detector gating and two-stage sounder options 508.013.036.T
extinguishing system. The micro-processor based • Extinguishing 'hold' and 'abort' facilities T530 4 Zone Fire Detection and Extinguishing
T530 provides four fire detection zones, two of • Zone test and sounder test facilities Control Panel - Thorn branded
which are dedicated to the extinguishing area • Integral power supply 599.001.020
(coincident operation) and two for the protection of • Can be installed to meet the requirements Spare lamp - 36V 30mA bi-pin
the peripheral areas. The T530 monitors the BS5839 Part 1 & BS6266
connections to the external sounders, pressure • Designed to comply with BS7273 527.001.013
switches, actuators, etc. and initiates the • One man walk test Spare Frangible Washers (Pack of 25)
appropriate actions in response to signals from • 4 zone capacity 509.013.145
either the detection zones or manual release • Zone Isolate T530 Programmed EPROM Version 4.0
units. The T530 also incorporates facilities for Technical Specification
'hold' or 'abort' of the gas discharge (prior to Datasheet - Product Code PSF30 “T530 Fire
Mains Supply: 240V a.c. 50Hz Detection & Extinguishing Systems Control Unit”
release) and remote status indication.
Charger Output: 24V d.c. 2.5A continuous Manual - FSSD-1.1.30.1 “Fire Detection Manual”
The microprocessor enables a high level of
Quiescent Current: 24V d.c. 220mA
integrity to be achieved, including self-checking

T520 Extinguishing Coincidence Control Panel


has 2 inputs from an external detection system. Product Codes
The T520 carries the extinguishing coincidence 508.013.035.A
functionality on these inputs before implementing
T520 Extinguishing Coincidence Control Panel -
the extinguishing release procedure. The T520
ADT branded
does not include a mains power supply and
requires an external 24Vd.c. supply. 508.013.035.T
Technical Specification T520 Extinguishing Coincidence Control Panel -
Thorn branded
Power Supply: 24Vd.c.
599.001.020
Quiescent Current: 172mA
Spare lamp - 36V 30mA bi-pin
Alarm Current: 320mA +Sounders
527.001.013
Dimensions: 268H x 397W x 98Dmm
Spare Frangible Washers (Pack of 25)
Weight: 5Kg
Operating Temp: -10 to +55oC
Datasheet - Product Code PSF30 “T530 Fire
Storage Temp: -20 to +65oC
Detection & Extinguishing Systems Control Unit”
Humidity: up to 95% RH non-
The T520 provides similar functionality to the Manual - FSSD-1.1.29.1 “Fire Detection Manual”
condensing
T530 without the detection capability. The T520 EMC/RFI: CE marked

T510 Extinguishant Changeover Unit


The T510 is a manual keyswitch operated unit for Weight: 2 Kg
use with T530, T520, System 1700 or System 750 Operating Temp: -10 to +55oC
extinguishing systems. The unit allows manual
Humidity: up to 95% RH non-
changeover between MAIN and RESERVE
condensing
cylinder banks and includes an OFF position that
disables the operation of the solenoids. The T510 EMC/RFI: CE marked
also provides a fault relay, which monitors the Product Codes
solenoid and solenoid wiring. The T510 is 526.001.016.A
provided with 2 keys.
T510 Extinguishing - Main To Reserve
Technical Specification Changeover Unit - ADT branded
Input power supply: 24Vd.c. nominal 526.001.016.T
Current consumption:Standby - 50mA T510 Extinguishing - Main To Reserve
Fault - 15mA Changeover Unit - Thorn branded
Release - 65mA (excluding
solenoid)
Datasheet - Product Code PSF30 “T530 Fire
Fault relay: Changeover contact 1A @
Detection & Extinguishing Systems Control Unit”
30V d.c.
Manual - FSSD-4.1.8.1 “Fire Detection Manual”
Solenoids: Switched positive for 24V
Dimensions: 196 H x 196 W x 90 D mm

Page 33
tyco Fire & Tyco Electronic
Security Product Group
T525 Extinguishing Mode Select Switch
up to 8 units can be connected to an NTR, T520 Humidity: up to 95% RH non-
or T530 system alternatively two T525 units can condensing
be configured in a "tunnel" mode for entry and exit IP rating: IP54
routes on a watchman's tour.
EMC/RFI: CE marked
The T525 incorporates dual long life / high
Product Codes
brightness lamps to indicate system status as
follows: 526.001.021.A
Gas Release: Red T525 Extinguishing System Auto/Manual Mode
Select - Unbranded
Automatic Mode: Yellow
526.001.021.T
Manual Mode: Green
T525 Extinguishing System Auto/Manual Mode
Mode Select operated: Green
Select - Thorn branded
Technical Specification
599.001.012
Input power supply: 24Vd.c. nominal
Spare lamp 28V 60mA for use on T525
Current consumption:Standby - 212mA max.
The T525 is a remote mode select and indication Alarm - 318mA max.
Datasheet - Product Code PSF30 “T530 Fire
unit for use with NTR, T530, T520 and System Lamps rating: 28Vd.c. @ 60mA rated for
Detection & Extinguishing Systems Control Unit”
1700 extinguishing systems. Normally sited at the 8000 hours
entrance to the hazardous area, this allows Manual - FSSD-4.1.8.1 “Fire Detection Manual”
Dimensions: 138 H x 178 W x 52 D mm
personnel to enter or leave without risk of being Weight: 1 kg
caught in an automatic gas discharge. Typically
Operating Temp: -20 to +55oC

T526 HOLD & T529 ABORT Switch Unit


The T526 and T529 are large mushroom head Product Codes
robust push buttons for use on any extinguishing 526.001.019.A
release system, though integral resistors are fitted
T526 Extinguishing Release Hold Button Unit -
to suit T520, T530 and NTR panels. The switch is
Unbranded
double pole for maximum reliability. These
switches can be surface or flush mounted using 526.001.019.T
standard UK style single gang electrical back T526 Extinguishing Release Hold Button Unit -
boxes. Thorn branded
Operation will vary according to the panel used. 526.001.020.A
Typically on the T520 and T530 release of gas is T529 Extinguishing Abort Button Unit -
held for as long as the T526 HOLD switch is Unbranded
depressed. If the switch remains depressed for
526.001.020.T
more than 4 minutes in the quiescent mode then
a fault condition is raised. The T529 ABORT T529 Extinguishing Abort Button Unit - Thorn
switch will typically revert the system back to branded
Manual mode.
Technical Specification Datasheet - Product Code PSF30 “T530 Fire
Dimensions: 71H x 71W x 64D (max) mm Detection & Extinguishing Systems Control Unit”
Manual - FSSD-4.1.8.1 “Fire Detection Manual”
Weight: 100g
Environmental: Designed for indoor use

T527 Electrical / T528 Mechanical Manual Release Units


These manual release units provide a robust 526.001.017.T
module with a hinged flap retained by frangible T527 Electrical Manual Extinguishing Release
washers which ensures that there is an audit trail Push Button Unit - Thorn branded
following a manual release.
526.001.018.A
The T527 provides a reliable double pole
T528 Mechanical Manual Extinguishing Release
pushbutton switch, whilst the T528 provides
Unit - Unbranded
access to a pull handle which can be connected
to the release levers on the gas containers using 526.001.018.T
wire rope. T528 Mechanical Manual Extinguishing Release
Technical Specification: Unit - Thorn branded
Dimensions: 71H x 71W x 64D (max) mm 527.001.013
Weight: 100g Spare Frangible Washers (Pack of 25)
Environmental: IP54
Product Codes Datasheet - Product Code PSF30 “T530 Fire
Detection & Extinguishing Systems Control Unit”
526.001.017.A
Manual - FSSD-4.1.8.1 “Fire Detection Manual”
T527 Electrical Manual Extinguishing Release
Push Button Unit - Unbranded

Page 34
tyco Fire & Tyco Electronic
Security Product Group
Weatherproof Extinguishing Indicator Units

540.007.001
E1 Single Red lamp unit
Heavy Duty IP67 Cast Aluminium Surface Mount
Lamp Unit. Single 24V d.c. red lamp labelled 540.007.006
'Extinguishing System Operated' 540.007.002
I3 Red/Amber/Green lamp unit
E3 Red/Amber/Green lamp unit
Technical Specification Sealed IP67 ABS Surface Mount Lamp Unit
Heavy Duty IP67 Cast Aluminium Surface Mount
Dimensions: Three 24V d.c. lamps:
Lamp Unit Three 24Vd.c. lamps:
H(mm) W(mm) D(mm) Red labelled 'Gas Released'
Red labelled 'Extinguishing System Operated'
E1 100 100 115 Amber labelled 'Auto'
Amber labelled ' Extinguishing System Automatic
E3 300 100 115 Control' Green labelled 'Manual'
I3 230 75 75 Green labelled 'Extinguishing System Manual 540.007.007
I4 230 75 75 Control' I4 lamp unit as I3 including auto/manual keyswitch

Extinguishing Door Interlock Ancillaries & T500 Series Spares


The UNION Mortice Escape Deadlock can be Product Codes 599.001.011
used with a handle on the inside of the door to 527.001.001 (Temporarily Unavailable) Lamp 28V 40mA Midget Used On T505/515
ensure that exit is possible even if the door is UNION 21972 Mortice Escape Deadlock 599.001.012
locked. A microswitch lock keep can be used with
527.001.028 Lamp 28V 60mA Used On T525
the deadlock to provide a signal to the T525 mode
select unit or direct to the panel to ensure that the Micro-switch Lock Keep & Back-plate For 599.001.020
extinguishing system is only put into Automatic Deadlock
Lamp 36V 30mA Bi-Pin Used On T520 & T530
mode when the door is locked shut. 527.001.003
Top Hat Frangible Insert (Spare)
Datasheet - Product Code PSF30 “T530 Fire 527.001.013
Detection & Extinguishing Systems Control Unit” Frangible Washers (Spare)
Manual - FSSD-4.1.8.1 “Fire Detection Manual”

Typical Schematic for T550/530 Controlling an FM200 System

Peripheral area detection Discharge area detection

Pre-discharge sounders
Alarm sounders

Pressure Switch

Container
Remote Signalling Fault Input
Solenoid
Valve

Power FM200
AC Container
Supply
T526
T525 T527 /T529

Page 35
tyco Fire & Tyco Electronic
Security Product Group
Conventional Marine Panels (See also MINERVA Section)
T1000
• 4 monitored Relay outputs Product Codes
• 3 programmable auxiliary inputs 508.022.035
• 3 levels of alarm discriminations per zone
• One common fault relay T1008 8 zone marine NT conventional fire
• Programmable cause and effect Controller
• Can interface to intrinsically safe System 601 508.022.036
• Manned/ unmanned mode T1016 16 zone marine NT conventional fire
Technical Specification
Controller
Dimensions: 320H x 430W x 150D mm
508.022.037
Weight: 6.3kg
T1016R repeater for use with T1008 & T1016
Power Supply: 198 -264Va.c.
Quiescent Current: 50mA @ 24Vd.c.
Alarm Current: 1Amp @ 24Vd.c. Datasheet - Product Code PSF96 “T1000
The range of T1000 panels are state-of-the-art Operating Temp: 0 to +40°C Intelligent Control Panels”
intelligent fire panels, which provide many of the
Operating Humidity: 0-90% RH non-condensing
features normally only found on more expensive
analogue addressable panels. The panels are Optional Product Codes 509.022.012
supplied in 8 and 16 zone versions. Each The following product codes include all the Bulkhead Mounting Kit
detection zone can support up to 32 conventional optional extras which can be included as part of
detectors. The user interface is provided through 509.022.013
your customer's requirements. Additional spare
a combination of LEDs and a 2 x 40 character Flush Mount Bezel
parts are also included.
LCD display. The LCD display provides a full 509.022.014
509.022.001
customer definable text display of the alarm or NT 3 Metre -Cable Assembly For Connection Of
fault condition whilst also displaying zones in NT100 Series Spare Commissioning Kit Included
NTX-01 To NTX-02/3/4 Typically Used For
alarm, fault or isolate status. The display also With All Panels
Connection To Remote NTX-02 Relay Unit
indicates the outputs that have been activated. 509.022.003
509.022.015
Features NT100 4 Way Expansion Board - Support NTX-
T1000 Display PCB Spare
• Developed for Vessels with less than 300 02,03,04 Expansion Boards
509.022.016
Detectors 509.022.004
• Approved by all Major Marine Authorities T1000 CPU board V1.6 spare
NT100 16 Way Relay Output Board (24Vd.c.@1A)
• Customer friendly, multi language information Requires NTX-01 Expansion Board 509.022.024
on LCD display T1000R CPU board V1.6R spare
509.022.005
• Comprehensive fault diagnostics
NT100 16 Way Digital Output Driver Board - 509.022.034
• 8 and 16 zone Panels
• Can be used with a wide range of Minerva Requires NTX-01 Expansion Board NT PSU Plug In Fuse 2 (Pack Of 10)
Marine approved Detectors 509.022.010
• 4 monitored Sounder outputs up to 4A Spare PSU For T1000

T882 Four Zone Marine Fire Controller


Features Size With Power Without Power
• Approved by a variety of marine authorities Unit Unit
• Up to 4 fire detection zones Height 267mm 267mm
• Two alarm levels per detection zone (except
Width 398mm 398mm
I.S. zones)
• Two monitored bell circuits selectable as con- Depth 187mm 102mm
tinuous or intermittent Weight: 10Kg 8.5Kg
• Secondary alarm output delay (up to 3 mins)
• Integral power changeover or battery charger
option Product Codes
• Panel test mode 508.013.030
• Faults can be set to either latching or non- T882 Control Panel c/w Power Unit
latching
508.013.031
The T882 control unit is intended for marine use • Can interface to intrinsically safe System 601
• Lamp dim feature T882 Control Panel 24Vd.c. only
throughout the world. The T882 has two sounder
circuits. In the event of an alarm the primary bell • Replaceable legend 509.013.064
circuit will operate the sounders in selected areas. Other Input/Output facilities (rated 1A at 30Vd.c. T882 Power Unit
If the alarm is not accepted ("Silenced") within resistive):-
400.007.002 (Available from Thorn Marine)
three minutes, the secondary circuit will operate • Two monitored sounder circuits rated at
T882 Handbook
all the other sounders in the system. Any manual 24Vd.c. 1A each.
Alarm callpoint will override the sounder delay. A • One silenceable and one non-silenceable 560.001.013
manual Alert callpoint will not override the delay of Common Alarm contact Battery 6V 10Ah
the secondary circuit. The T882 can be powered • One latching/non-latching fault contact 509.013.081
using one of three options: • Four zonal alarm auxiliary contacts Long voyage spares kit
1/ with internal power unit • Repeater outputs switched to common
• One fused 24Vd.c. 1A output 509.013.080
The ship's 110/240V a.c. supply is the primary
• One external fault monitoring input Short voyage spares kit
supply, switching to a monitored ship's 24V d.c.
Technical Specification
supply in the event of primary supply failure.
Operating temp.: -25°C to +55°C Manual - UHM2 “Marine Fire Manual”
2/ with internal power unit
Storage temp.: -25°C to +70°C
The ship's 110/240V a.c. supply is the primary
supply, switching to an internal monitored and Humidity: 95% RH non-condensing
charged 24V d.c.-battery supply (Four off, 6V 10Ah The T882 control panel is fitted directly to the
lead acids) in the event of primary supply failure. bulkhead. Housing is zinc plated 1.6mm thick mild
3/ without internal power unit steel.
The ship's 24V d.c. supply is the only supply
connected.
Page 36
tyco Fire & Tyco Electronic
Security Product Group
T881 8 Zone Marine Fire Controller
@ 30Vd.c. resistive Product Codes
• One latching common fault contact rated 3A @ 508.013.018
30Vd.c.
T881Control Unit shallow
Terminal Field B:-
• 8 zonal relay contacts rated 1A @ 30Vd.c. 508.013.020
resistive. T281Repeater unit
Options:- 401.006.012 (Available from Thorn Marine)
• Optional lamp dim module used to provide a
Sounder pulsing module
variable output to the controller lamp supply for
dimming purposes. This is normally only 400.007.001 (Available from Thorn Marine)
required if the system does not use a T680 T881Handbook
power changeover unit. 401.011.008 (Available from Thorn Marine)
• Optional sounder pulsing module to permit pre- Bezel for deep housing
defined sounder circuit pulsing configurations.
• Optional Earth leakage monitor 401.011.009 (Available from Thorn Marine)
Technical Specification Bezel for shallow housing
Operating temp.: -25°C to +70°C 509.013.001
The T881 control unit forms the heart of a
sophisticated and flexible marine fire detection Storage temp.: -25°C to +70°C Nicad battery for total power fail warning (included
system. The T881 provides control of up to 8 Humidity: 95% RH non-condensing with new control panel)
conventional zones of fire detection. The unit The control panel is normally mounted onto a 509.013.051
comprises, display and electronics PCB assembly, bulkhead using the H frame bracket. Bezels for T881 front cover
terminal field A and terminal field B in either a both deep and shallow housings are available. 509.013.052 (price on application)
deep or shallow housing. The deep housing The deep housing has two removable gland
permits the convenient installation of additional T281 front cover
plates (top and bottom) for cable access. The
optional circuit boards in the same housing. The shallow housing has eight 20mm knock outs, both 509.013.059
control panel normally receives its power from the top and bottom. Zone output/ mimic drive pcb
T680 power changeover unit, or alternatively, the 509.013.062
Housing is zinc plated 1.6mm thick mild steel.
C2440, if ship's 24Vd.c. supply is not available.
Finish is grey epoxy powder paint 9-094, to Zone output PCB c/w ribbon connector
Features
BS2660. 509.013.048
• Approved by a variety of marine authorities
Front cover assembly moulded from a flame Terminal Field A
• Up to 8 fire detection zones
retardant polyester glass filled compound, finished 509.013.061
• Two alarm levels per detection zone (except
in blue-grey 9-098, to BS2660
I.S. zones) Terminal Field E
• 2 monitored bell circuits selectable as continu- 509.013.108
T881 T881 T281
ous or intermittent
Deep Shallow Shallow Lamp dim module
• Secondary alarm output delay (up to 3 mins)
• Multiplexed data I/O Size (mm) 509.013.056
• Interfaces directly with up to four T281 8 zone Height 385 385 390 T881 Spares kit
repeater unit or zonal mimic drive pcbs Width 398 398 398 509.013.057
• Panel test and isolate mode
Depth 171 95 95 T281 Spares kit
• Can interface to intrinsically safe System 601
• Lamp dim feature Weight Kg
• Replaceable legend With H frame 15 10 13.5 Datasheet - Product Code PSF16 “System 1600
Other input/output facilities:- Conventional Fire Controller”
Without H frame 11.5 6.5 10.5
Terminal Field A:- Manual - UHM1 “Marine Fire Manual”
IP rating 53 53 53
• Zone terminals 1-8
• Two monitored sounder circuits rated at 4Vd.c.
2.5A each.
• One latching common alarm contact rated 3A

Page 37
tyco Fire & Tyco Electronic
Security Product Group
T880 Thirty-Two Zone Conventional Marine Fire Controller
• One latching common alarm contact rated 3A Product Codes
@ 30Vd.c. resistive 508.013.012
• One latching common fault contact rated 3A @
T880 Control Unit Deep
30Vd.c.
Terminal Field E:- 508.013.013
• Zone terminals 9 to 32 T880 Control Unit shallow
• 4 relays rated 1A @ 30Vd.c. resistive. The 508.013.002
relays can be programmed to activate by
T280 Repeater Unit
zone(s) with an additional zonal mimic drive
PCB, 401.006.012 (Available from Thorn Marine)
Options:- Sounder pulsing module
• Optional lamp dim module used to provide a 400.007.003 (Available from Thorn Marine)
variable output to the controller lamp supply for T880 Handbook
dimming purposes. This is normally only
required if the system does not use a T680 401.011.008 (Available from Thorn Marine)
power unit. Bezel for deep housing
The T880 control unit forms the heart of a • Optional sounder pulsing module to permit 401.011.009 (Available from Thorn Marine)
sophisticated and flexible marine fire detection predefined sounder circuit pulsing Bezel for shallow housing
system. The T880 provides control of up to 32 configurations.
• Optional Earth leakage monitor 509.013.001
conventional zones of fire detection. For
Technical Specification Nicad battery for total power fail warning (included
exceptionally large vessels, up to three controllers
Operating temp.: -25°C to +70°C with new control panel)
may be linked together to give 96 zones of fire
detection. The T880 unit comprises, display and Storage temp.: -25°C to +70°C 509.013.002
electronics PCB assembly, terminal field A and T880 front cover
Humidity: 95% RH non-condensing
terminal field E in either a deep or shallow 509.013.059
housing. The deep housing permits the The control panel is normally mounted onto a
bulkhead using the H frame bracket. Bezels for Zone output/ mimic drive PCB
convenient installation of additional optional circuit
boards in the same housing. The control panel both deep and shallow housings are available. 509.013.062
normally receives its power from the T680 power The deep housing has two removable gland Zone output PCB c/w ribbon connector
changeover unit, or alternatively, the C2440, if plates (top and bottom) for cable access. The
509.013.048
ship's 24Vd.c. supply is not available. shallow housing has eight 20mm knock outs, both
top and bottom. Terminal Field A
Features
Housing is zinc plated 1.6mm thick mild steel. 509.013.061
• Approved by a variety of marine authorities
Finish is grey epoxy powder paint 9-094, to Terminal Field E
• Up to 32 fire detection zones
• Two alarm levels per detection zone (except BS2660. 509.013.108
I.S. zones) Front cover assembly moulded from a flame Lamp dim module
• 2 monitored bell circuits selectable as retardant polyester glass filled compound, finished 509.013.055
continuous or intermittent in blue-grey 9-098, to BS2660.
T880 Spares kit
• Secondary alarm output delay (up to 3 mins)
T880 T880 T280 509.013.028
• Multiplexed data I/O
• Interfaces directly with up to four T280 32 zone Deep Shallow Shallow T280 Spares kit
repeater unit or zonal mimic drive PCB’s Size (mm) 509.013.121
• Panel test and isolate mode Height 385 385 390 T880 variable legend kit
• Can interface to intrinsically safe System 601
Width 398 398 398
• Lamp dim feature
• Replaceable legend Depth 171 95 95 Datasheet - Product Code PSF16 “System 1600
Other input/output facilities:- Weight Kg Conventional Fire Controller”
Terminal Field A:- With H frame 15 10 13.5 Manual - UHM3 “Marine Fire Manual”
• Zone terminals 1-8 Without H frame 11.5 6.5 10.5
• Two monitored sounder circuits rated at IP rating 53 53 53
24Vd.c. 2.5A each.

T680 Marine Power Change Over Unit


The T680 power changeover unit derives power Technical Specification Dimensions: 267H x 398W x 150D mm
for the T880 and T881 control panels. The unit Operating temp.: -25°C to +70°C Ingress Protection: IP53
takes primary power from the ship's AC supply
Storage temp.: -25°C to +70°C Weight: 17Kg (with bracket)
and provides a standby supply from the ship's
24Vd.c. system i.e. the unit does not charge any Humidity: 95% RH non-condensing 13.5Kg (without bracket)
internal batteries. The T680 unit provides a Mains Supply: 120/240Va.c. ± 20% Product Codes
smooth changeover from primary to secondary at 50/60Hz 508.013.016
supply and vice-versa. It signals main and
Standby Supply: 24Vd.c. (must not exceed T680 Power changeover unit
standby supply failure signals to the T88x control
32Vd.c.) 509.013.026
equipment. It also incorporates a dimming circuit
for the lamps of the controller. The T680 unit is normally mounted onto a T680 Spares kit
bulkhead using the H frame bracket. A bezel for
The interface to the control panel is made with
19" rack mounting is available. The housing has
over a six core connection. The unit is approved Manual - UHM3 “Marine Fire Manual”
two removable gland plates (top and bottom) for
by a variety of marine authorities
cable access.
Housing is zinc plated 1.6mm thick mild steel to
BS 1706 ZN3.
Finish is zinc plated and painted to P.S.
121.121.022.

Page 38
tyco Fire & Tyco Electronic
Security Product Group
Batteries, PSU and Door Release
Batteries
Product Codes 3071 560.001.015
660.001.003 Battery sealed L-A replaces 660.001.009 and 30- Battery sealed L-A also replaces 3148, SLA17
Battery sealed L-A 105 and 30-109
560.001.013 660.002.010 660.001.004
Battery sealed L-A also replaces parts 3145 and Battery sealed L-A also replaces 3146, SLA04 Battery sealed L-A (Bolt terminal) also replaces
30-102 and 30-112 3014, SLA24 and 30-106
3085 3072 560.001.012
Battery sealed L-A also replaces 660.001.014 and Battery sealed L-A also replaces 660.001.005, Battery sealed L-A also replaces 3149, SLA38
SLA07 and 30-101 and 30-107
30-111
660.002.012 3150
3010
Battery sealed L-A also replaces 3147, SLA012 Battery sealed L-A also replaces SLA65 and 30-
Battery sealed L-A also replaces 660.001.007,
and 30-110 108
SLA21 and 30-103

Product Codes Model No. Voltage (V) Ah Dimensions (mm)


Length Width Height
660.001.003 NP1.2-6 6 1.2 97 25 54.5
560.001.013 NP10-6 6 10 151 50 97.5
3085 NP1.2-12 12 1.2 97 48 54.5
3010 NP2.1-12 12 2.1 178 34 64
3071 NP2.8-12 12 2.8 151 50 97.5
660.002.010 NP4-12 12 4 90 70 106
3072 NP7-12 12 7 151 65 97.5
660.002.012 NP12-12 12 12 151 98 97
560.001.015 NP17-12 12 17 76 180 165
660.001.004 NP24-12B 12 24 175 166 125
560.001.012 NP38-12 12 38 179 165 170
3150 NP65-12 12 65 350 166 174

Door Release Equipment


Cable Release & Release Button
The 77CR19 cable release unit is used for
automatically closing roller shutter doors in the
event of a fire.
Technical Specification
Dimensions: 130H x 17W x 65D mm
Weight: 2.5Kg
Voltage: 240Va.c. / 24Vd.c.
Current: Negligible / 500mA
Temp.: -20oC to +45oC

518.003.003 519.001.007 Holding Force: 50Kg


77CR19 Cable release 24Vd.c. Door release button UK single gang mounting IP Rating: IP40
518.003.004
77CR19 Cable release 240Va.c.

Door Release Magnet


High quality Tyco Electronic Product Group door
release magnet sets complete with keeper plate.
Technical Specification
Power Supply: 24Vd.c. 240Va.c.
Dimensions: 100H x 100W x 64D mm
Weight: 0.51Kg
Holding Force: 18Kg
IP Rating: IP40
Temp.: -10oC to +55oC
Current: 60mA 25mA
518.004.004 518.004.005
Door Release Magnet Set 240Va.c. Door Release Magnet Set 24Vd.c.

Page 39
tyco Fire & Tyco Electronic
Security Product Group
Door Release Units
Technical Specification - Door Release Units

40-103 40-104
Dimensions: 85H x 85W x 46D mm
Armature Dims: Dia 72mm x 21mm deep
Voltage: 24Vd.c. 230Va.c.
Hold Force: 17Kg 20Kg
Current: 60mA 20mA
Product Codes Product Code Residual Magnetism: 5% 5%
40-103 40-105
Door release unit 24Vd.c. with keeper plate Floor mounting brackets for 40-103/104
40-104 Dimensions: 100H x 85W x 55D mm
Door release unit 240Va.c. with keeper plate
Cable Entry: 20mm
Door Release Power Supply
The Transformer Rectifier is a dual purpose, Technical Specification
smoothed power supply providing either an Input: 240Va.c.
energised or de-energised output upon activation. Output: 24Vd.c. 3A
The output may be activated by utilising a set of
volt free contacts from a fire or security panel, or Dimensions: 230H x 320W x 75D mm
by providing a 12/24Vd.c. trigger voltage from Product Code
other apparatus. The transformer rectifier units are 558.004.007
normally used to control the operation of other TRR-243 3A Door Release PSU
24Vd.c. equipment such as the magnetic door
retainers. The units are ideal for applications
where the supply is to be energised from a remote
source.

General Power Supply Units


Datasheet - Product Code PSF25 “C2400 Series Power Supply Unit”
Manual - FSSD-4.1.4.1 “Fire Detection Manual”

C Range Chargers
lead-acid battery and an attractive housing. Under • Automatic protection for short-circuit conditions
normal conditions, the charger provides all the is designed to prevent damage
system power and maintains the battery in the
charged condition. When the AC supply fails, the • Optional voltmeter and ammeter
stand-by battery takes over. Technical Specification
Features Operating Temp: -20oC to 55oC
Storage Temp.: -20oC to +70oC
• A range of chargers and housings to suit
different system configurations Relative Humidity: 95% RH non-condensing
Output Voltage: 27Vd.c.
• May be used with both conventional and
Product Codes
analogue addressable fire systems
558.004.006
The C2400 series power supply equipment • Large aluminium heatsink eliminates need for
C Range charger 24V 4 Amp
provides primary and secondary power for fire unsightly ventilation grills
558.004.003
alarm systems. The power supply consist of an • Temperature compensated output ensures C Range charger 12V 4Amp
AC supply operated charger, a stand-by sealed correct charging voltage at all times

Housing Type D
The housings are designed to match the current Product Codes
range of fire alarm controllers. The housings are 558.004.013
available in two sizes and can be supplied with an
Housing Type D complete with metres
ammeter and voltmeter if required. An ‘AC supply
on’ indicator is fitted. 558.004.014
Technical Specification Housing Type D
Type D: 420H x 436W x 210D mm
Holds charger and up to 2 x 38Ah sealed batteries
at 24V d.c.

Housing Type C
The housings are designed to match the current Product Codes
range of fire alarm controllers. The housings are 558.004.015
available in two sizes and can be supplied with an Housing Type C complete with metres
ammeter and voltmeter if required. An ‘AC supply
558.004.016
on’ indicator is fitted.
Housing Type C
Technical Specification
Type C: 290H x 416W x 160D mm
Holds charger and up to 2 x 12Ah sealed batteries
at 24V dc

Page 40
tyco Fire & Tyco Electronic
Security Product Group
Addressable 900 Series Detectors
Body Optical Ionisation HPO R of R Heat CO Features
LPCB MR901 MF901 MR901T MD901 MU901 • Unique early detection CO fire detector
NSTC MF901 MR901T • Intelligent Universal HPO Smoke Detector
• Low profile, discreet and unobtrusive
UL/FM* 912P 912I 912HP 912H
• Superior performance and reliability
ULC 912P/C 912I/C 912PH/C 912H/C • Unique ‘Smart Key’ feature
Marine MR901M MF901M MD901 • Designed for fast, easy installation
The M900 series are a range of low profile The M900 series includes the unique Carbon • Optional Locking Kit
addressable fire detectors. These unobtrusively Monoxide CO fire detector, which provides a • Integral and remote alarm LED
styled detectors have a number of unique design general purpose fire detector with unprecedented • Series of Product Approvals
features to improve their operation, installation early detection capability and excellent false alarm
and ease of servicing. immunity. The CO fire detectors are the first The M900 Low Profile detectors can be custom
Through innovative design the M900 Series choice for sleeping risks. made in several colours, please contact the
detectors have reduced the installation and Also included within the range is the intelligent Walthamstow office for details.
servicing time to a minimum, needing only one high performance optical smoke (H.P.O.) detector.
visit to complete the installation. The detectors The use of the patented optical sensing chamber,
also have a park position, which eases detector together with refined signal processing, has
servicing. enabled the introduction of a smoke detector
The unique smart key feature ensures that the suitable for fast, reliable smoke detection of both
address is transferred to the base after slow and fast developing fires. The H.P.O. can be
installation. This ensures that the detector seen as a truly universal smoke detector, suitable
addresses are not accidentally confused during for most applications.
* FM Approval pending at time of going to press
service visits.

Carbon Monoxide Fire


The CO fire detector is a unique Product Codes Approval Branded Model
general purpose fire detector which 516.059.001.A LPCB ADT MU901
provides very early warning of slow
516.059.001.T LPCB Thorn MU901
smouldering fires. Ideal for
sleeping risks the CO fire detector 516.059.001.Y LPCB Tyco MU901
is also well suited to many
applications where heat detection is insufficient
but smoke detection causes false alarms. Datasheet - Product Code PSF94 “Carbon
As CO travels more freely than smoke the Monoxide Fire Detector”
positioning of CO fire detectors is more flexible. Manual - Vol01B-03-D7 “Detectors Fire Manual”
This feature is particularly useful in large complex
structures such as atria and warehouses, where
positioning of smoke detectors is difficult. The
MU901 is LPCB approved in normal and high
sensitivity settings.

High Performance Optical Smoke


These detectors react to the whole Product Codes Approval Branded Model
range of fire products from slow 516.055.001.A LPCB ADT MR901T
smouldering fires, producing visible
516.055.001.T LPCB Thorn MR901T
particles to open flaming fires
producing large numbers of very 516.055.001.Y LPCB Tyco MR901T
hot smaller sized aerosols. It 516.055.031 UL Thorn 912HP
combines optical and heat detector technology to 516.055.032 ULC Thorn 912HP/C
detect clear burning fire products which hitherto
515464 UL Grinnell 912HP
could only be easily detected by ion-chamber
alarm level. The HPO will not operate on a rate of
detectors.
rise of temperature alone.
For normal ambient conditions, the high
performance optical detector behaves as a normal
optical detector. When a rapid rise in temperature Datasheet - Product Code PSF84 “M600/900 Low
is detected the sensitivity of the detector Profile Fire Detector Range”
increases and the presence of smoke will confirm Manual - Vol01B-03-D4 “Detectors Fire Manual”
a fire condition which will be transmitted as an

Optical Smoke
These detectors are capable of Product Codes Approval Branded Model
detecting the visible smoke
516.057.001.A LPCB ADT MR901
produced by materials which
smoulder or burn slowly, i.e. soft 516.057.001.T LPCB Thorn MR901
furnishings, plastic foam etc;. or 516.057.001.Y LPCB Tyco MR901
'smoke' produced by overheated 515463 UL Grinnell 912P
but unburnt PVC. These detectors are particularly
suitable for general applications and areas where 516.057.031 UL Thorn 912P
cable overheating may occur e.g. electrical 516.057.032 ULC Thorn 912P-C
services areas. The novel design of the 516.057.401 Marine Thorn MR901M
asymmetrical sampling chamber and signal
processing techniques stop unwanted alarms
caused by very small insects. i.e. thrips. Smoke Datasheet - Product Code PSF84 “M600/900 Low
entering the sampling chamber scatters the infra- Profile Fire Detector Range”
red light pulses onto a photodiode These pulses Manual - Vol01B-03-D6 “Detectors Fire Manual”
are converted to an electrical signal which is
transmitted as an analogue value.
Page 41
tyco Fire & Tyco Electronic
Security Product Group
Heat
These detectors use two Product Code Approval Branded Model
networked thermistors in a bridge 516.053.001.A LPCB ADT MD901
configuration to provide a fast
516.053.001.T LPCB Thorn MD901
response, that depends both on
absolute temperature and notes 516.053.001.Y LPCB Tyco MD901
the change of temperature. The 516.053.002 UL Thorn 912H
rate of rise/fixed temperature heat detectors can 515461 UL Grinnell 912H
be used in areas where smoke sensors are
unsuitable due to environmental conditions
(smoke, dust etc,). Such areas include kitchens, Datasheet - Product Code PSF84 “M600/900 Low
locker rooms, canteens, garages, loading bays Profile Fire Detector Range”
etc.
Manual - Vol01B-03-D5 “Detectors Fire Manual”
The integral electronics emulate conventional fire
detector's response curves and transmit the state
to a controller as an analogue representation of
the ambient temperature conditions.

Ion Chamber Smoke


These detectors react to the visible Product Code Approval Branded Model
and invisible fire aerosols 516.051.001.A LPCB ADT MF901
(products of combustion) and are
516.051.001.T LPCB Thorn MF901
therefore capable of detecting the
early presence of hot smouldering 516.051.001.Y LPCB Tyco MF901
and flaming fires, such as wood, 516.051.031 UL Thorn 912I
paper etc. 516.051.032 ULC Thorn 912I-C
They are particularly suitable for general 515462 UL Grinnell 912I
applications in all areas and use a dual ionisation
516.051.401 Marine Thorn MF901M
chamber in which the air is ionised by a single
radioactive source (33k Bq Americium 241). The
presence of smoke in the sampling chamber Datasheet - Product Code PSF84 “M600/900 Low
causes a change in the balance voltage, between Profile Fire Detector Range”
the two chambers. This is then converted to a
Manual - Vol01B-03-D3 “Detectors Fire Manual”
current level and transmitted as an analogue
value.

Technical Specification
Typical Dimensions of Standard 4” Detector

Technical Specification - M901 Series


MD/MR MF MU
Weight 112g 137g 137g
Material FR 110 Bayblend
Operating Temp. -20 to +70oC -20 to +70oC 0 to +50oC
Storage Temp. -25 to +80oC -25 to +80oC -20 to +50oC
Relative Humidity 95% Non-Condensing
Quiescent Current(typ) 240µA 120µA 120µA

Page 42
tyco Fire & Tyco Electronic
Security Product Group

Page 43
tyco Fire & Tyco Electronic
Security Product Group
Conventional 600 Series Detectors
Body Optical Ionisation HPO R of R Heat FT CO Features
LPCB MR601 MF601 MR601T MD601 MD611 60°C MU601 • Unique early detection CO fire detector
NSTC MF601 MR601T • Intelligent Universal HPO Smoke Detector
• Low profile, discreet and unobtrusive
SSL/NZ* MR614 MF614 MR614T MD614 MU614
• Superior performance and reliability
UL/FM# 612P 612I 612HP 612H 622H 135°F • Attractive new design
632H 200°F • Designed for fast, easy installation
VdS MR613 MF613 MR613T MD613 MD623 • Optional Locking Kit
• Integral and remote alarm LED
Marine MR601M MF601M MD601 MD611
• Series of Product Approvals
*Available from Grinnell Detection Products in Melbourne & Grinnell Supply Sales N.Z. The M600 low Profile detectors can be custom
The M600 series are a range of low profile general purpose fire detector with unprecedented made in several colours, please contact the
conventional fire detectors. These unobtrusively early detection capability and excellent false alarm Walthamstow office for details
styled detectors have a number of unique design immunity. The CO fire detectors are the first
features to improve their operation, installation choice for sleeping risks.
and ease of servicing. Also included within the range is the intelligent
Through innovative design the M600 series high performance optical smoke (H.P.O.) detector.
detectors have reduced the installation and The use of the patented optical sensing chamber,
servicing time to a minimum, needing only one together with refined signal processing, has
visit to complete the installation and having a Park enabled the introduction of a smoke detector
position for the detector to ease the servicing. suitable for fast, reliable smoke detection of both
The M600 series includes the unique Carbon slow and fast developing fires. The H.P.O. can be
seen as a truly universal smoke detector, suitable # FM Approval pending at time of going to press
Monoxide CO fire detector, which provides a
for most applications.

Carbon Monoxide Fire


The CO fire detector is a unique Product Codes Approval Branded Model
general purpose fire detector which 516.058.001.A LPCB ADT MU601
provides very early warning of slow
516.058.001.T LPCB Thorn MU601
smouldering fires. Ideal for
sleeping risks the CO fire detector 516.058.001.Y LPCB Tyco MU601
is also well suited to many 516.058.001.W LPCB Wormald MU601
applications where heat detection is insufficient 561.0130 None Zettler MU601
but smoke detection causes false alarms.
As CO travels more freely than smoke the
Datasheet - Product Code PSF94 “Carbon
positions of CO fire detectors is more flexible.
Monoxide Fire Detector”
This feature is particularly useful in large complex
Manual - Vol01B-04-D7 “Detectors Fire Manual”
structures such as atria and warehouses, where
positioning of smoke detectors is difficult. The
MU601 is LPCB Approved.

High Performance Optical Smoke


These detectors react to the whole Product Codes Approval Branded Model
range of fire products from slow 516.054.001.A LPCB ADT MR601T
smouldering fires, producing visible
particles to open flaming fires 516.054.001.T LPCB Thorn MR601T
producing large numbers of very 516.054.001.Y LPCB Tyco MR601T
hot smaller sized aerosols. It 561.0320 VdS Zettler MR613T
combines optical and heat detector technology to
detect clear burning fire products which hitherto 516.054.042 VdS Thorn MR613T
could only be easily detected by ion-chamber 516.054.001.W VdS Wormald MR613T
detectors. 515458 UL Grinnell 612HP
For normal ambient conditions, the high 516.054.031 UL Thorn 612HP
performance optical detector behaves as a normal
optical detector. Only when a rapid rise in
temperature is detected does the sensitivity of the Datasheet - Product Code PSF84 “M600/900 Low
detector increase and the presence of smoke will Profile Fire Detector Range”
confirm a fire condition. The HPO will not operate Manual - Vol01B-04-D4 “Detectors Fire Manual”
on a rate of rise of temperature alone.

Optical Smoke
These detectors are capable of Product Codes Approval Branded Model
detecting the visible smoke 516.056.001.A LPCB ADT MR601
produced by materials which
516.056.001.T LPCB Thorn MR601
smoulder or burn slowly, i.e. soft
furnishings, plastic foam etc;. or 516.056.001.Y LPCB Tyco MR601
'smoke' produced by overheated 561.0310 VdS Zettler MR613
but unburnt PVC. These detectors are particularly 516.054.041 VdS Thorn MR613
suitable for general applications and areas where
516.054.041.W VdS Wormald MR613
cable overheating may occur e.g. electrical
services areas. The novel design of the 515457 UL Grinnell 612P
asymmetrical sampling chamber and signal 516.056.031 UL Thorn 612P
processing techniques stop unwanted alarms 516.056.401 Marine Thorn MR601M
caused by very small insects. i.e. thrips. Smoke
entering the sampling chamber scatters the infra-
red light pulses onto a photodiode These pulses Datasheet - Product Code PSF84 “M600/900 Low
are converted to an electrical signal which is Profile Fire Detector Range”
compared against a preset alarm level. Manual - Vol01B-04-D6 “Detectors Fire Manual”

Page 44
tyco Fire & Tyco Electronic
Security Product Group
Heat
These detectors use two Rate of Rise
networked thermistors in a bridge Product Codes Approval Branded Model
configuration to provide a fast
516.052.001.A LPCB ADT MD601
response, that depends both on
absolute temperature and notes 516.052.001.T LPCB Thorn MD601
the change of temperature. The 516.052.001.Y LPCB Tyco MD601
rate of rise/fixed temperature heat 561.0340 VdS Zettler MD613
detectors can be used in areas
516.052.013 VdS Thorn MD613
where smoke sensors are
unsuitable due to environmental 516.052.013.W VdS Wormald MD613
conditions (smoke, dust etc,). Such 515453 UL Grinnell 612H
areas include kitchens, locker 516.052.031 UL Thorn 612H
rooms, canteens, garages, loading bays etc.
Fixed Temperature 60°C
The integral electronics emulate conventional fire
Product Codes Approval Branded Model
detector's response curves and transmit the state
to a controller as an alarm condition. 516.052.011.A LPCB ADT MD611
516.052.011.T LPCB Thorn MD611
Datasheet - Product Code PSF84 “M600/900 Low 516.052.011.Y LPCB Tyco MD611
Fixed Temperature 90°C Profile Fire Detector Range” 516.052.033 VdS Thorn MD623
Product Codes Approval Branded Model Manual - Vol01B-04-D5 “Detectors Fire Manual” 516.052.033.W VdS Wormald MD623
515455 UL Grinnell 632H 515454 UL Grinnell 622H
516.052.022 UL Thorn 632H 516.052.032 UL Thorn 622H

Ion Chamber Smoke


These detectors react to the visible Product Codes Approval Branded Model
and invisible fire aerosols 516.050.001.A LPCB ADT MF601
(products of combustion) and are
516.050.001.T LPCB Thorn MF601
therefore capable of detecting the
early presence of hot smouldering 516.050.001.Y LPCB Tyco MF601
and flaming fires, such as wood, 561.0330 VdS Zettler MF613
paper etc. 516.050.041 VdS Thorn MF613
They are particularly suitable for general 516.050.041.W VdS Wormald MF613
applications in all areas and use a dual ionisation 516.050.031 UL Thorn 612I
chamber in which the air is ionised by a single
radioactive source (33k Bq Americium 241). The 515456 UL Grinnell 612I
presence of smoke in the sampling chamber 516.050.401 Marine Thorn MF601M
causes a change in the balance voltage, between
the two chambers. This is then compared against Datasheet - Product Code PSF84 “M600/900 Low
an alarm level. Profile Fire Detector Range”
Manual - Vol01B-02-D1/D3 “Detectors Fire
Manual”
Technical Specification
Typical Dimensions of Standard 4” Detector

Technical Specification - M601 Series


MF MR MD MU
Weight 134g 122g 114g 137g
Material FR 110 Bayblend
Operating Temp. -20 to +70oC -20 to +70oC -20 to +70oC* -20 to +50oC
Storage Temp. -25 to +80oC -25 to +80oC -20 to +70oC -25 to +70oC
Relative Humidity 95% Non-Condensing
Quiescent Current(typ) 70µA 60µA 50µA 50µA
Alarm Current(typ) 40mA 36mA 40mA 40mA
Operating Voltage 18-32Vd.c. 18-32Vd.c. 18-32Vd.c. 18-32Vd.c.
*Short Term (<3min) -40 to +120oC

Page 45
tyco Fire & Tyco Electronic
Security Product Group

Page 46
tyco Fire & Tyco Electronic
Security Product Group
Standard Detector Bases
The Standard Universal detector bases are compatible with both conventional (M600) and analogue (M900) addressable detectors. The bases have no
electronics and even when the detectors are connected to the bases, they can be electrically disconnected and left in a “park” position. This enables wiring
integrity tests to take place without any damage to electronics. When used with addressable detectors, the smart card access key automatically transfers to
the base, thus the address remains with the base even if the detector is changed or replaced. An optional, tool removable locking pin allows the detector to be
fixed in place to prevent tampering.

M600/900 and 4B - 4 Inch Universal Base


Features 517.050.601
• Variety of fixing options 4B - 4” Universal mounting base for UL Approved
• Remote LED connections Detectors - Thorn Branded.
• Available with continuity diode fitted
• Anti-tamper facility
Datasheet - Product Code PSF64 “Series
• LPCB, Vds, Marine approved (M600/900)
300/400/500 Fire and Smoke Detectors”
• UL approved (4B)
Product Codes Manual - Vol01B-02-D2 “Detectors Fire Manual”
517.050.001
M600/900 4” Universal mounting base for LPCB,
Vds approved detectors
571.0700 - (K07226456)
M600/900 4” Universal mounting base for LPCB,
Vds approved detectors - Zettler Branded
The 4 inch base is designed to fit directly to the
ceiling or various common backboxes. This base 515467
allows a detector to be fitted indirectly or a 4B - 4” Universal mounting base for UL Approved
functional base to be plugged in between the base Detectors - Grinnell Branded.
and detector.

M600D Continuity Base


ensure that the conventional system meets the
requirements of BS5839 Pt: 4 for call-points
placed after detectors. The M600D works with XL,
NT, System 1700, MINERVA 1 to 4, MINERVA
DM520 and MDM520 Modules.
Product Codes
517.050.007
M600D Diode continuity mounting base. Datasheet - Product Code PSF84 “M600/900 Low
509.018.006 Profile Fire Detector Range”
Active End of Line Unit for use with M600 Manual - Vol01B-03-D2 “Detectors Fire Manual”
conventional detectors (not required on NT and
The M600D Continuity base is a standard 4 inch XL panels which are supplied with special EOL
base fitted with a continuity diode, for use with all devices)
M601 Series detectors. The Base is designed to

6” Universal Base
The 6” base is specially designed for applications Product Codes
using the US style single gang backbox. The 6” 515468
base provides an alternative to the 4” base in 6B Lo Pro detector base (6”) Grinnell branded.
most applications and is particularly useful where 517.050.606
large holes in the ceiling need covering or where UL 6B Lo Pro detector base (6”) Thorn Security
ceilings suffer from condensation. branded. Suitable for use with LPC and Vds
Features approved detectors
• Variety of fixing options
• Sealed back and cable entry
• Remote LED connections
• Anti-tamper facility
• UL approved (6B)

Page 47
tyco Fire & Tyco Electronic
Security Product Group
Functional Detector Bases
Functional detector bases use a common moulding which incorporates a double side circuit board which enables electrical connections to be made on the top
and bottom of the functional base. This allows the functional bases to be retrofitted into new and existing universal bases or alternatively the depth and cost of
the installed detector can be reduced by using the functional base instead of the universal base. This feature enables additional line isolators and sounders to
be easily added during commissioning. In addition, changes to the building during it’s life can be easily adapted to, by retrofitting sounders and relay outputs to
existing detection points.
When functional bases are fitted to universal bases, they automatically lock into position. Removal is then achieved using the detector removal tool. This
feature ensures that the detector and functional bases are removed separately.
When used on addressable systems, the MC900 and MB900 take the same address as the detector. This increases the number of devices on a loop and
significantly improves fault monitoring. Any attempt to remove the functional base will generate a fault on the system.
Datasheet - Product Code PSF101 “M600/900 Low Profile Detector Bases”
Manual - Vol01B-06-D1 “Detectors Fire Manual”

MB600 Conventional Sounder Base


single point sound source is used to provide Vibration: Exceeds requirements of
complete audio coverage without obtrusive holes prEN54-3 Marine & UL268
in the moulding. Power Supply: 28Vd.c.
Features Volume Setting 1: 70dbA
• 3 Selectable tones (slow, fast and continuous) Volume Setting 2: 80dbA
• 3 Volume settings (90, 80 and 70dB @ 1m)
Volume Setting 3: 90dbA
• Power consumption from 10mA
• Single point sound source Product Codes
• Frequency compatible with all other MINERVA 577.001.030
Banshees MB600 Conventional sounder base compatible
• Can be used in place of a standard base with any M600 and M900 low profile detector
• Complies with pr EN54 pt3
577.001.034
Technical Specification
The MB600 sounder provides a conventional MB600D Conventional sounder base with diode
Operating Temp.: -25 to 70oC
sounder which blends easily with the detector, fitted for use in place of M600D
providing the same tone as the rest of the range Humidity: Up to 96% RH
of MINERVA electronic sounders. A unique design (non-condensing)

MB900 Loop Powered Addressable Sounder Base


loop. The MB900 is controlled by the powerful Technical Specification
event action of the addressable MINERVA fire Operating Temp.: -25 to 70oC
panel. This allows the MB900 to sound when its
Humidity: Up to 96% RH (non-
own detector is in alarm or as a zonal sounder. By
condensing)
using the same address as the detector, the
sounder increases the number of devices per Vibration: Exceeds requirements of
loop. prEN54-3 Marine & UL268
Features Power Supply: Loop
• From 24 (90dbA) to 48 (70dbA) sounders per Volume Setting 1: 70dbA
loop (plus 99 detectors) Volume Setting 2: 80dbA
• 3 Selectable tones (slow, fast and continuous) Volume Setting 3: 90dbA
• 3 Volume settings (90, 80 and 70dB @ 1m)
Product Code
• Single point sound source
• Frequency compatible with other MINERVA 577.001.031
The MB900 sounder includes the same features banshees MB900 Loop powered sounder for use with M901
as the MB600 with the added benefit of being • Easily retrofitted addressable detectors on loop powered MINERVA
powered from the two wire MINERVA addressable • Can be used in place of a standard base systems
• Complies with pr EN54 pt3

mA MB600 MB900

25 50 48
20
20 40 36
15
15 30 24
10
10 20

5 10

70dbA 80dbA 90dbA 70dbA 80dbA 90dbA


(1/2 LPU) (3/4 LPU) (1 LPU)

Page 48
tyco Fire & Tyco Electronic
Security Product Group
MC900 & 900RBA Functional Relay Base
even when the relay is energised, enable the relay Vibration: Exceeds requirements of
base to be used without any additional power. On prEN54-3 Marine & UL268
addressable systems, the dual contacts operate Power Supply: Loop/Circuit
when the detector is in alarm OR when
Product Codes
commanded to do so by the panel.
568.001.016
Features
MC900 Relay base (BS 5839)
• Dual pole 24V d.c. relay contacts (60VA)
• Status indication LED 568.001.019
• Very low power consumption (<20µA except 900 RBA Relay base (UL -Thorn)
start up)
• Can be used in place of a standard base 515591
Technical Specification 900 RBA Relay base (UL - Grinnell)
Operating Temp.: -25 to 70°C
The 900 Series relay base provides dual relay
Humidity: Up to 96% RH (non-
contacts for signalling external devices on
condensing)
addressable systems. Very low operating current

MC600 & 600RBA Functional Relay Base


operating current even when the relay is Technical Specification
energised, enable the relay base to be used Operating Temp.: -25°C to +70°C
without additional power. The relay contacts
Humidity: Up to 95% RH (non
operate when the detector enters alarm condition.
condensing)
Features
Vibration: Exceeds requirements of
• Dual pole 24Vd.c. relay contact (60VA) prEN54-3, Marine & UL268
• Status indicator LED
Product Codes
• Low power consumption (<20µA except start
up) 568.001.018
• Latching operation MC600 Relay base (BS5839)
• Can be used instead of a standard base 568.001.020
• Requires diode fitting if used in place of an
600 RBA Relay base (UL - Thorn)
M600D diode base. Not compatible with
The 600 Series relay base provide dual relay System 1600 or T880 panels 515590
contacts for signalling external devices on 600 RBA Relay base (UL - Grinnell)
conventional detection systems. Very low
MI900 Analogue Addressable Loop Line Isolator
The MI900 incorporates the same circuitry as the Technical Specification
LI520 MKII line isolator to provide a flexible and Operating Temp.: -25 to 70°C
easily installed line isolation protection on Humidity: Up to 96% RH (non-
MINERVA analogue addressable systems. As the condensing)
line isolator is easily inserted or removed, future
Vibration: Exceeds requirements of
system changes can be implemented to suit
prEN54-3 Marine & UL268
changes in building use with minimum disruption.
Power Supply: Loop
Features
Product Code
• Up to 12 isolators per loop
• Status indication LED 545.001.008
• Easily retrofitted MI900 Line isolator base for use with M900
• Complies with BS5839 detectors on MINERVA systems (also compatible
with TFX systems but not UL approved)

Detector Locking Pin Kit


Product Codes Datasheet - Product Code PSF64 “Series
517.050.005 300/400/500 Fire and Smoke Detectors”
M69 Detector locking pin kit (Pack of 100) Manual - Vol01B-03-D2 “Detectors Fire Manual”
571.0710
Zettler Detector locking pin kit (Pack of 100)
(K07226458)
515476
Grinnell detector locking pin kit (Pack of 100)

Page 49
tyco Fire & Tyco Electronic
Security Product Group
M600/900 Detector Anciliaries
M600/900 Anciliaries

Product Code Product Codes Product Codes


517.050.010 517.051.002 (Supplied in 10’s) 515473
M600/900 Base Dust Cover (Pack of 10) M900 Smart card address key SA6/900 Line Shorting Adaptor (Grinnell)
515472 (Supplied in 10’s) 517.050.002.A
900 Smart card address key (Grinnell) Low profile line shorting adaptor commissioning
517.051.402 (Supplied in 10’s) tool - ADT Branded
M900M Smart card address key (Marine) 517.050.002.T
Low profile line shorting adaptor commissioning
tool - Thorn Branded

Product Codes Product Codes Product Codes


517.050.003.A 517.051.007 517.051.008
CA600 Low profile line continuity adaptor M900F Smart card address key programmer M900C Smart card address key programmer for
commissioning tool - ADT branded freestanding use with Consys
517.050.003.T 515474 515475
CA600 Low profile line continuity adaptor M900F Address key programmer (Grinnell) M900C Smart Card Address key programmer for
commissioning tool - Thorn branded TFX (Grinnell)

Product Code Product Codes Product Code


540.003.006.T 517.001.231 517.050.011
Remote Indicator LED square UK single gang DHM69 Deckhead mounting for M600/900 series W500 White powder coated steel protective cage
mounting (Thorn Branded) for use with 517.001.181 for M6/900 series detectors also suitable for most
conventional detectors. other smoke detectors. 120mm dia x 80mm deep
DHM7 Earthing strip

Page 50
tyco Fire & Tyco Electronic
Security Product Group
Duct Probe Air Sampling
MP/SMP Duct Probe Units withstand the more demanding environments of MP69 SMP69 MP35 SMP35
The MP/SMP Duct Probe Units are designed to the offshore oil and gas industries. Height 90mm 90mm 116mm 116mm
be installed in air conditioning supply and exhaust The units are designed to operate in airspeeds of Width 145mm 150mm 145mm 150mm
ducts for the purpose of monitoring the airflow for 1.5 to 25 metres per second. A range of sampling
Length 220mm 225mm 220mm 225mm
smoke and combustion products. tubes from 525mm to 1575mm is available
Weight 0.58Kg 1.2Kg 0.35Kg 1Kg
The MP69 and SMP69 probe units are designed Technical Specification
to accept and operate with the M600 and M900 Operating temperature: -20°C to +70°C
series detectors. MP35 and SMP35 duct probe
Storage temperature: -25°C to +80°C
units are available for use with M300 and M500
intrinsically safe series detectors and bases. For Relative Humidity: 0 to 95%
general applications it is recommended that MP## "Bayblend" housing with transparent
photoelectric smoke detectors rather than polycarbonate cover
ionisation smoke detectors are used. SMP## Stainless steel 316 housing with
The SMP stainless steel probe unit is designed to transparent polycarbonate cover

Warning Siting
Duct probe units sited in the common duct work to Duct probe units should always be sited as near to the point of extraction from the room as possible and
several extract grills may fail to respond to smoke in lengthy duct work runs, at intervals along the run. Probes should be mounted at the least turbulent
from any one extract due to the effect of dilution. sections of the ducting. Avoid installation immediately behind fans, bends or work sections.
The MP/SMP units will not respond to airflow of
less than 1.5m/sec.

MP69 & MP35 Duct Probe Air Sampling


Product Codes 517.001.038
517.025.036 DP900 Probe Tube 900mm and exhaust
MP69 Duct Probe unit and base for M600/900 517.001.039
Series DP1200 Probe Tube 1200mm and exhaust
517.025.021 (PSF64) 517.001.040
MP35 duct probe unit for M300/500 series DP1500 Probe Tube 1500mm and exhaust
517.001.035
DP450 Probe Tube 450mm and exhaust
Datasheet - Product Code PSF91 “MP69 Duct
517.001.036 Probe Unit” and PSF64 “Series 300/400/500 Fire
DP600 Probe Tube 600mm and exhaust & Smoke Detectors”
517.001.037 Manual - Vol01B-06-D1 “Detectors Fire Manual”
DP750 Probe Tube 750mm and exhaust

SMP69 & SMP35 Duct Probe Air Sampling - Stainless Steel


517.025.027 (PSF64) 517.025.032
SMP35 duct probe unit stainless steel for DPS1200 Probe tube stainless steel 1200mm and
M300/500 series exhaust
517.025.028 517.025.033
DPS450 Probe tube stainless steel 450mm and DPS1500 Probe tube stainless steel 1500mm and
exhaust exhaust
517.025.029
DPS600 Probe tube stainless steel 600mm and Datasheet - Product Code PSF92 “SMP69 Duct
exhaust Probe Unit” and PSF64 “Series 300/400/500 Fire
517.025.030 & Smoke Detectors”
DPS750 Probe tube stainless steel 750mm and Manual - Vol01B-06-D1 “Detectors Fire Manual”
Product Codes exhaust
517.025.035 517.025.031
SMP69 Stainless Steel Duct Probe unit and DPS900 Probe tube stainless steel 900mm and
universal detector base for M600/900 series exhaust
(available from July 1998)

Page 51
tyco Fire & Tyco Electronic
Security Product Group
Aspirating Smoke Detectors VESDA - Vision Systems
VESDA LaserPLUSTM, is a high sensitivity aspirating smoke detector. It provides both an early warning to facilitate intervention, and a suppression (Fire 2)
signal to initiate release at an appropriate level, eliminating the need for a separate detection system. The system is modular, displays and programmers can
be installed only where needed. Many VESDA products are also available from stock in German. German product codes are shown in brackets where they
exist.
Datasheet - Product Code PSF105 “VESDA LaserPLUS”

VESDA LaserCOMPACTTM
achieved through the combination of approved • Optional remote display and relay capability
LaserPLUS detection technology, dual stage • Simple mounting design
filtration technology and a modified aspirator • AutoLearnTM
design incorporated in a smaller enclosure with
simplified display. LaserCOMPACT is available in Technical Specification
two versions, one that interfaces via relays only Supply Voltage: 18 to 30Vd.c.
(RO) or across either the relays or VESDAnetTM Current Consumption:170mA quiescent,
(VN). 190mA in alarm
Features Dimensions: 225H 225W x x 85Dmm
• Reduced size Weight: 1.9Kg
• Absolute smoke detection Operating Temp.: -10oC to 39oC
• Wide sensitivity range Sampled Air: -20oC to 60oC
• Single pipe inlet Product Codes
• Simple display 516.018.010 (561.043)
• Referencing VLC-505 VESDAnet Version (VN)
• VESDAnet communication (VN) 516.018.011 (561.042)
The LaserCOMPACT detector has been
• Dual stage dust filter VLC-500 Relays Only Version (RO)
specifically designed to provide all the benefits of
• Three alarm levels See also Remote Displays
aspirating smoke detection, including very early
• Configurable relays
warning, in single environment small areas and
• Air flow monitoring
where space is a premium. This has been

LaserPLUS Standard Modular Range - LaserPLUS Detectors


The detector assembly contains the laser Features Technical Specification
detection chamber, high efficiency aspirator, • Wide sensitivity range Supply Voltage: 18 to 30Vd.c.
monitored filter cartridge, control electronics, and • Laser-based light source Current Consumption: (No display or programmer)
relay interface. The detector assembly can be • 4 Configurable alarm levels 240mA quiescent plus 50mA
used as a “distributed” system, with the display, • Purpose built Aspirator alarm (24Vd.c. & 3000 rpm)
programmer and VESDAnet socket modules • 4 In-line Inlet pipes Dimensions: 225H x 350W x 125D mm
mounted in a remote location. Alternatively, the • Flow sensor for each inlet pipe Weight: 4.0Kg (including display and
detector assembly can be configured as a “self- • Wide range DC power programmer modules)
contained” system by replacing the detector’s • Low-cost maintenance Operating Temp.: 0oC to 39oC
blank panels with the display and/or programming • Dual stage filter Humidity: 0-95% RH, non condensing
modules. • Easy access to filter cartridge
• 7 Software configurable relays
• Recessed mounting
• Multiple exhausts

516.018.001 (561.036) 516.018.002 (561.037) 516.018.003


VLP-012 LaserPLUS Detector, programmer and VLP-002 LaserPLUS Detector and display VLP-000 LaserPLUS Detector
display

516.018.013 (561.038)
VLP-400 LaserPLUS Detector with fire OK LED

Page 52
tyco Fire & Tyco Electronic
Security Product Group
LaserPLUS Scanners - 7 & 12 Relay Output Variants
VESDA LaserPLUS is also available in a Scanner Features Technical Specification
configuration, which allows the system to • Individual pipe annunciation Supply Voltage: 18 to 30Vd.c.
distinguish and identify the pipe carrying smoke, • Adaptive scan threshold Current consumption: (No display or programmer)
while sampling multiple sectors. • Wide sensitivity range (0.005 to 20% obs/m) 240mA quiescent plus 70mA
The VESDA LaserPLUS will continue to sample • Laser based light source alarm (24Vd.c. & 3000 rpm)
from all sectors to monitor the fire growth and • Configurable alarm levels Dimensions: 225H x 350W x 125D mm
maintain full protection. • Purpose built Aspirator Weight: 4.0Kg including display and
• 4 In-Line inlet pipes programmer modules
• Flow sensor for each pipe inlet Operating Temp.: 0oC to 39oC
• Low-cost maintenance Humidity: 10-95% RH, non condensing
• Dual stage filter Relay Outputs: 7 or 12
• Easy access to filter cartridge
• Recessed mounting

516.018.004 (561.044) 516.018.005 (561.045) 516.018.006


VLS-214 FD7 Scanner, programmer and display VLS-204 FD7 Scanner and display VLS-200 FD7 Scanner
516.018.007 (561.039) 516.018.008 (561.040) 516.018.016 (561.046)
VLS-314 FD12 Scanner, programmer and display VLS-304 FD12 Scanner and display with 12 VLS-600 FD7 Scanner with Fire OK LED
with 12 relays relays 516.018.009
VLS-300 FD12 Scanner
516.018.019 (561.041)
VLS-700 FD12 Scanner with Fire OK LED

Optional Remote Displays


has been reached, or a fault has occurred. obscuration)
It has a 20 segment vertical bargraph, a 2-digit • Acknowledged push-button presses
numerical display, an audible sounder and clear • Multiple language supported
alarm and fault indicators. It also has 4 push • Addressable to any detector
buttons to control the detector and the mode of Technical Specification
the display. Supply Voltage: 18-30Vd.c. (when used in
Displays can be located at a convenient location - detector unit, Remote unit or
either within the detector module, or remotely on 19” rack)
the VESDAnet. For monitoring convenience, Current Consumption: 60mA quiescent plus 20mA
multiple displays can be associated with a single alarm @24Vd.c. - (module
detector. only)/90mA quiescent plus
Features 20mA alarm @24Vd.c. (in
516.018.101 (571.084) • Four alarm levels (Alert/Action, Fire 1 & Fire 2) remote mounting box)
VRT-100 Remote programmer • 20 segment vertical bargraph Dimensions: 150H x 140W x 90D mm
• Alarm threshold indicators Operating Temp.: 0°C to 39°C
A display module monitors the VESDA (Alert, Action & Fire 1) Humidity: 10-95% RH, non condensing
LaserPLUS detector. It reports a visual • Audio and visual indication
representation of smoke levels, and all alarm and • Alarm indicators
fault conditions. The internal sounder warns • Informative fault indicators
personnel in the local area that an alarm threshold • Multi-mode numeric display(defaults to smoke
Scanner Displays Detector Displays Other Remote Modules

516.018.104 516.018.102 516.018.103 (571.104)


VRT-400 Remote scan display including 7 relays VRT-200 Remote display including 7 relays VRT-300 Remote VESDAnet socket
516.018.107 (571.083) 516.018.106 (571.082) 516.018.105
VRT-700 Remote scanner display - no relays VRT-600 Remote detector display- no relays VRT-500 Blank detector remote unit with 7 relays
516.018.108 516.018.119 516.018.109
VRT-800 Remote scanner display with 12 relays VRT-J00 Compact Display c/w 7 relays VRT-900 Blank scanner remote unit with 12 relays
516.018.120 516.018.110
VRT-K00 Compact Display no relays VRT-000 Spare remote housing
516.018.114
VRT-E00 Blank scanner remote unit with 7 relays

Page 53
tyco Fire & Tyco Electronic
Security Product Group
LaserPLUS Standard 19 Inch Sub-Rack Remote Display Assemblies
Product Codes 516.018.251
516.018.201 VSR-4000 19” Sub-rack with 1 scanner display
VSR-2000 19” Sub-rack with 1 detector display and 3 blank
and 3 blanks 516.018.252
516.018.202 VSR-4100 19” Sub-rack with 1 scanner display,
VSR-2100 19” Sub-rack, 1 detector display, programmer and 2 blanks
programmer and 2 blanks 516.018.253
516.018.203 VSR-4410 19” Sub-rack with 2 scanner displays,
VSR-2210 19” Sub-rack, 2 detector displays, programmer and 1 blank
programmer and 1 blank 516.018.254
516.018.204 VSR-4441 19” Sub-rack with 3 scanner displays
VSR-2221 19” Sub-rack with 3 detector displays and programmer
and programmer 516.018.255
The 19” sub-rack is available as a mounting
516.018.205 VSR-4443 19” Sub-rack with 3 scanner displays
option, with 4 mounting slots for display or
VSR-2223 19” Sub-rack with 3 detector displays and VESDAnet socket
programming modules.
and VESDAnet socket 516.018.256
Technical Specification
516.018.206 VSR-4444 19” Sub-rack with 4 scanner displays
Dimensions: 128H x 482W x 120D mm
VSR-2222 19” Sub-rack with 4 detector displays

LaserPLUS Components for Ordering Custom Built Remote Display Sub-racks


x VSU-2 configured as VSR-0022) 516.018.214
Note: The order of the numbers (e.g. 0022) VSU-E Blank scanner sub-unit with 7 relays
indicates the order in which the sub-units will be 516.018.266
mounted in the sub-rack housing when looking VSU-6 Detector display sub-unit no relays
from the front of the unit - from left to right 516.018.267
Product Codes VSU-7 Scanner display sub-unit no relays
516.018.260 516.018.268
VSU-0 Blank Sub-unit VSU-8 Scanner display sub-unit with 12 relays
516.018.261 516.018.269
VSU-1 Programmer sub-unit VSU-9 Blank display sub-unit with 12 relays
516.018.262 516.018.219
Sub-rack configurations other than those available VSU-2 Detector display sub-unit plus 7 relays VSU-J Compact display sub-unit plus 7 relays
as standard can be supplied as custom built units. 516.018.263 516.018.220
The sub-rack and cost of assembly are included in VSU-3 VESDAnet socket sub-unit VSU-K Compact Display sub-unit no relays
the VSR-CUSTOM. 516.018.564 516.018.210
The configuration of the custom built unit must be VSU-4 Scanner display sub-unit plus 7 relays VSR-CUSTOM Custom sub-rack housing includes
specified at time of ordering (e.g. 2 x VSU-0 and 2 516.018.265 cost of custom building 4 VSU sub-rack units.
VSU-5 Blank sub-unit with 7 relays

LaserPLUS Standard 19 Inch Rack Remote Display Assemblies


Standard rack enclosures are available to fit 2 Product Codes
(see picture) or 5 sub-rack assemblies. 516.018.301
Technical Specification 020-052 19” Rack enclosure (2 rows)
Dimensions: 516.018.302
020-052 400H x 600W x 220D mm 020-055 19” Rack enclosure (5 rows)
020-055 800H x 600W x 220D mm 516.018.303
020-050 300H x 400W x 140D mm 020-050 IP65 Enclosure

LaserPLUS Ancillaries & Power Supply Unit


A variety of other ancillaries are available. Tyco Product Codes
Electronic Product Group do not stock pipe and 517.017.005
sampling points but can source these, on behalf of Sampling point label
our customers, with next day delivery from our 517.017.006
suppliers. Aspirating pipe label
516.018.402 (571.086)
VHX-0200 PC link HLI plus leads (MK2)
516.018.403 (571.089)
VSW-004 VConfig Basic software
Available on request
VSW-005 VConfig Pro software
516.018.404 (571.090)
VSW-002 Aspire Windows software
516.018.401 (571.085) 516.018.407
VHH-100 Hand held programmer plus leads VESDA 24Vd.c., 2A Power supply and charger

Page 54
tyco Fire & Tyco Electronic
Security Product Group
LaserPLUS Spares
Product Codes 516.018.515
516.018.501 VSP-015 Spare aspirator fan
VSP-002 Display (spare) 516.018.516
516.018.502 VSP-016 Spare header termination card 12 relays
VSP-004 Scanner display (spare) 516.018.520
516.018.503 VSP-020 Set of spare plastic screw covers
VSP-001 Programmer (spare) 516.018.530
516.018.505 VSP-100 Spare blank plate for Fire OK models
VSP-019 Filter cover door (spare) 516.018.532
516.018.506 VSP-102 Spare detector relay processor
VSP-006 Spare detector chassis and manifold 516.018.533
516.018.508 VSP-103 Spare scanner relay processor
516.018.504 VSP-008 Spare remote termination card 7 relays 516.018.534
VSP-005 Filter cartridge (spare) 516.018.509 VSP-200 Spare blank cover
VSP-009 Spare scanner chassis and manifold 516.018.535
The following common VESDA LaserPLUS spares 516.018.513 VSP-003 Spare VESDAnet kit
are kept in stock by Tyco Electronic Product VSP-013 Spare plastic detector cover 516.018.536
Group. Other spares can be supplied if required. 516.018.514 VSP-208 Spare remote termination card - 12 relay
VSP-014 Spare header termination card 7 relays

VESDA International Language Decals


All VESDA LaserPLUS products are currently
supplied from stock in Tyco grey with English
labels and software. Labels can be easily
changed to any of the languages below.
Alternatively, where large quantities are involved
Tyco Electronic Product Group can arrange for
special delivery of pre-labelled products - extra
delivery time must be allowed.

Language VESDA Scanner VESDA Detector VESDA Remote Terminal VESDA Laser Compact
Swedish 516.018.270 516.018.280 516.018.290 516.018.310
French 516.018.271 516.018.281 516.018.291 516.018.311
Spanish 516.018.272 516.018.282 516.018.292 516.018.312
German 516.018.273 (571.088) 516.018.283 (571.087) 516.018.293 516.018.313
Italian 516.018.274 516.018.284 516.018.294 516.018.314
Flemish 516.018.275 516.018.285 516.018.295 516.018.315
Dutch 516.018.276 516.018.286 516.018.296 516.018.316
Finnish 516.018.277 516.018.287 516.018.297 516.018.317
Danish 516.018.278 516.018.288 516.018.298 516.018.318

Page 55
tyco Fire & Tyco Electronic
Security Product Group
Special Hazards Detectors
S200 Plus Triple IR Solar Blind Flame Detector
• True window test in detection area (i.e. not in Technical Specification
the edge of the window) Detector Material: Stainless Steel 316L
• Terminals provided for Remote LED
Dimensions: 167H x 167W x 89D MM
connection
• BASEEFA (CENELEC) certified with other Weight: 4.5Kg
approvals in process Gland Entry: 3 x 20mm
• Meets the requirements of EN54 Pt10 Metal Parts: Bright Stainless Steel 316 to
• Submitted for FM, DNV and LRS
(external & internal) to BS
• Very low power consumption (0.35mA)
1449 Pt 2
• Models available with Conventional or
Analogue Addressable interface (requires 2 Tag Label: Stainless Steel 316
core cable only) Range: 0.1m2 petrol at 50m
The new MINERVA S200 PLUS flame detectors • Models also available with relay or 4-20mA 0.4m2 petrol at 60m
are the latest Infrared solar blind and multi- outputs
channel infra-red flame detectors with low power Response Time: Field Selectable 3,6 and 12s
• Patented dual filter solar blindness for
consumption and high false alarm immunity. complete solar blindness Sensitivity: 3 range settings
The MINERVA S200 PLUS range of advanced • 100°field of view on IS versions Relative Humidity: 95% (100% intermittent)
flame detectors is the most comprehensive range • 90° field of view on Flameproof versions Enclosure to: IP 66 and IP 67
available.
For information on flame detector test equipment,
Features Unlike other flame detectors on the market the please refer to the detector test equipment
• Triple waveband infrared solar blind flame MINERVA S200PLUS is available in both section.
detection for optimum false alarm immunity Intrinsically Safe (EEx ia) and Flameproof (EEx d)
models. Approvals
• Unrivalled black body rejection over a wide
The intrinsically safe models are suffixed by the BASEEFA Approved models are suffixed ‘1’. At
range of source temperatures
letter " i " and meet the requirements of EN50020 the time of going to print approval status is as
• Range adjustable to 50 metres for a 0.1m-2
part 7 and are BASEEFA certified EEx ia IIC T5. follows:
petrol pan fire
• Discrimination of optical faults (dirty windows) As part of an intrinsically safe circuit, it is suitable NSTC: Approved
from other faults in the built-in self test for zones 0,1 and 2 where group IIC gases or LPCB: Approved
• Housing designed for easy installation of lesser hazards can be continuously present in LRS: Pending
cabling explosive concentrations.
DNV: Pending
• Flexible mounting and angular adjustment The flameproof models are suffixed by the letter
• 3 x 20mm field cable entries FM Approved models are suffixed ‘2’. At the time
"f" and meet the requirements of EN50018 and
• IP66/67 housing designed for external use of going to print FM Approvals are imminent.
are BASEEFA certified EEx d IIC T6. The
• Rugged stainless steel ANC4 LM25 alloy detectors are suitable for zones 1 and 2 where
housing and mounting bracket group IIC gases or lesser hazards can be Product Code
• Operating temperature range of -40 to 80°C intermittently present in explosive concentrations. 517.001.249
• Variable response times and sensitivity
Weidmuller Q500-4A00 for S241f+
settings
• Remote self test and range setting Datasheet - Product Code PSF102 “Minerva S200
Plus Series”
Approvals
Interface BASEEFA FM Product Codes
Conventional 4-20mA Addressable Relay Ex ‘ia’ Ex ‘d’ Ex ‘d’
S231i+ ✔ ✔ 516.037.004
S231f+ ✔ ✔ 516.037.003
S232f+ ✔ ✔ 516.037.015
S241i+ ✔ ✔ 516.038.004
S241f+ ✔ ✔ 516.038.003
S251i+ ✔ ✔ 516.039.004
S251f+ ✔ ✔ 516.039.003
S252f+ ✔ ✔ 516.039.015
S261f+ ✔ ✔ 516.040.002
S262f+ ✔ ✔ 516.040.012

S200 Series Test Equipment


Product Codes Datasheet - Product Code PSF60 “T110/T210 Test
592.001.013 Source”
T210 Test source for use with (517.001.224) Solo Manual - Vol01A-01-G1 “Detectors Fire Manual”
704 Adaptor Tube B and Solo 100/101 Poles
(517.001.230/226)
592.001.014
T210 Adaptor required for the T210 to be used
with S200 and S200 Plus Flame detectors

Page 56
tyco Fire & Tyco Electronic
Security Product Group
S111 and S121 Series Flame Detectors
• Built in response indicator Connections
• High immunity to smoke, dust and grime S111 Milspec plug sealed into body
Technical Specification
Milspec mating socket with 2m of 4 core PVC
Material: Impact resistant moulded
insulated, braid screened PVC sheathed cable
plastic (light grey)
to DEF Std 61-12 Pts 4
Dimensions: 160H x 80W x 60D mm
(without bracket) S121 One 4 way, 2.5 mm heavy duty terminal
block
Weight: 0.6Kg
Product Codes
Gland Entry (S121): 1 x 20mm
516.009.006
Range: 0.1m2 petrol at 20m
S111 Infra-red Flame detector solar blind plug and
0.4m petrol at 40m
socket connection
Field of View: 85° min inclusive
516.009.008
The S111 and S121 (and variants thereof) are Response Time: 3 secs min, 5-10 secs typical
S121 Infra-red Flame detector solar blind screw
single sensor infra-red flame detectors with optical Supply Voltage: 15.5 to 25.5Vd.c. terminal connections
filtering, suitable for use outdoors in a wide range
Quiescent Current: 100µA max. at 20Vd.c. 516.009.014
of applications.
Alarm Current: 60 mA max S121 Infra-red Flame detector solar blind screw
Specifically designed for use in the demanding
environments of the onshore petro-chemical Operating Temp.: -30°C (-40°C with reduced terminal connections (Pyrotronics) FM Approved
industry, the S111 and S121 detectors incorporate range) to + 70°C 516.009.007
an abrasion resistant sapphire window in a Storage Temp.: -40°C to + 80°C S112 Infra-red Flame detector non solar blind plug
protective housing to meet IP65. Relative Humidity: 95% (100% intermittent) and socket connection
Features Enclosure to: IP65 516.009.015
• No false alarms from welding, sunlight or high Classification: BASEEFA EEx ia IIC T5 S122 Infra-red flame detector non solar blind
intensity lamps Suitable for use in zones 0,1 screw terminal connections
• Low maintenance costs and 2 where group IIC 516.009.019
• Quick response to carbon fires gasses or lesser hazards
• Good performance (20m) S122 Infra-red Flame detector non solar blind
are present in explosive
• Completely solar-blind for use outdoors screw terminal connections (Pyrotronics)
concentrations.
• High sensitivity with exceptional interference
BASEEFA Cert No.: Ex 812333
rejection Datasheet - Product Code PSF22 “S111/121 Infra
• BASEEFA approved EEx ia IIC T5 Red Flame Detector”
• Housing protection to IP65 Manual - Vol01A-04-D1/D2/D3 “Detectors Fire
• Integral stainless steel 316 mounting bracket Manual”
• 2 core interface to conventional fire systems

S131 Flame Detectors


conditions. The S131 Infra-red Flame Detector Response Time: 3 secs min
uses the same optical and electronic module as 5-10 secs typical
the S111 and S121 detectors. It therefore has
Product Codes
near identical performance characteristics making
it completely blind to solar radiation whether 516.009.023
direct, reflected or modulated. S131 Infra-red Flame detector solar blind
Technical Specification 516.009.028
Material: G.R.P. Anti-static, black S131 Infra-red Flame detector solar blind
Dimension: 160H x 160W x 90D mm Pyrotronics
(without bracket)
Weight: 2.85 Kg (including bracket) Datasheet - Product Code PSF58 “S131 Flame
Gland Entry: 2 x 20mm Detector”
The S131 has been specially packaged in a tough Manual - Vol01A-04-D4 “Detectors Fire Manual”
Range: 0.1m2 petrol at 20m
GRP anti-static housing with abrasion resistant
sapphire windows and protection against water 0.4m petrol at 40m
ingress under sustained, high wind driven Field of View: 90° min inclusive

S161 Flame Detector


completely blind to solar radiation whether direct, Alarm Indication: Red LED
reflected or modulated. In order to meet the Connections: Two 4 way 2.5mm heavy
demands of arduous environments, such as duty terminal blocks
chemical plants and off-shore oil and gas
Hazardous Area: BASEEFA Ex e s ib IIC T5.
platforms, the S161 detector has been packaged
Suitable for use in zones 1
in a tough G.R.P. anti-static housing, which makes
and 2 where group IIC
it mechanically similar to the S131 detector.
gases or lesser hazards are
Two 20mm cable entries and two 4-way terminal sometimes present in
blocks are provided, which eliminate the need for explosive concentrations.
a local junction box, reducing installation costs.
BASEEFA Cert. No: EX87Y 3550
When using the existing Ex‘d’ wiring associated
with UV detectors, the use of BASEEFA certified Product Code
glands rated Ex‘e’ is mandatory. 516.009.022
Technical Specification S161 Infra-red Flame detector solar blind
The S161 Infra-Red Flame Detector is specifically Supply Voltage: 18.0V to 24.0 V d.c. (polarity complete with built in intrinsically safe isolation
designed to replace installed UV units using conscious) area
existing Ex d wiring, making replacement highly
cost effective. Quiescent Current: 100µ A max. at 20V d.c.
Alarm Current: 2-wire, latching. Datasheet - Product Code PSF59 “S161 Flame
The S161 Infra-Red Flame Detector uses the Detector”
same optical and electronic module as the S111, 720 ohm in series with
S121 and S131 detectors. It therefore, has typically 4V switched across Manual - Vol01A-04-D5 “Detectors Fire Manual”
identical performance characteristics making it supply
Page 57
tyco Fire & Tyco Electronic
Security Product Group
S100 Series Test Equipment
Product Codes 592.001.010
592.001.012 T110 PP9 Battery and Charger kit
T110 Test Source for use with (517.001.224) Solo 592.001.011
704 adaptor tube B and Solo 100/101 poles T110 Carrying case (not suitable for T210)
(517.001.230/226)
592.001.004
Datasheet - Product Code PSF60 “T110/T210 Test
T110 Adaptor plate for S111/112/121/122 Source”
592.001.005 Manual - Vol01A-01-G2 “Detectors Fire Manual”
T110 Adaptor for S131/161
592.001.007
T110 Adaptor for M300/500

S100/200 Series Flame Detectors Mounting Bracket


Technical Specification Product Code
Weight: 1.1Kg 517.001.184
Dimensions: 202H x 130W x 72D mm Flame detector bracket assembly (Stainless Steel)
Construction: SS316 to BS1449 Pt. 2 for use with all S100/200 Series detectors

Axial Rotation: 360o


Datasheet - Product Code PSF76 “S200 Series
Elevation: 80o
Intrinsically Safe Flame Detectors”
Fixing: M8 bolts

Omniguard 860 UV/IR and 660 UV Flame Detectors


The S660 and S860 Series Flame Detectors are Product Codes
suitable for use in Class I, Division 1, Groups B, C 516.060.021
and D (explosion-proof) areas and Class II,
Meggitt Avionics Omniguard 860 UV/IR flame
Division 1, Groups E, F, and G (dust-ignition-
detector with self test. Stainless Steel construction
proof) areas. The housings are NEMA 4, dust-
and 3/4" standard connection
tight and watertight. The detectors are approved
for both indoor and outdoor installations. 516.060.022
Features Meggitt Avionics Omniguard 860 UV/IR flame
detector with self test. Aluminium construction and
• Microprocessor Based.
3/4" standard connection. Yellow finish
• 0 to 60 seconds user adjustable time delays.
• User adjustable latching or non-latching fire 516.060.025
relays. Meggitt Avionics Omniguard 660 UV flame
These detectors allow UV and UV/IR flame • User adjustable sensitivity & NO or NC relay detector with self test. Stainless Steel construction
detection to be offered where specifically specified outputs. and 3/4" standard connection
or in the few applications where the S200Plus • LED indication: fire (red), fault (amber). 516.060.026
Triple IR flame detector is not suitable, such as • Transient voltage (surge) protection.
Meggitt Avionics Omniguard 660 UV flame
metal fires. The 860 UV/IR flame detector • RS485 addressable user interface.
detector with self test. Aluminium construction and
replaces the existing S850 UV/IR flame detector. • Two seconds or less to a 2 ft. x 2 ft. fire of JP-
3/4" standard connection. Yellow finish
All aluminium detectors are now available in 4, JP-8, Jet A, Jet B, AVTUR and AVGAS at
100 feet. 517.060.001
MINERVA yellow.
• Three seconds or less to a 10 ft. x 10 ft. fire of 4651027 Meggitt Avionics swivel bracket in black.
Stocklisted Omniguard sensors are available with
JP-4, JP-8, Jet A, Jet B, AVTUR and AVGAS For use with Aluminium body detectors
automatic self-test, latching fire relays and 3/4"
at 250 feet. 517.060.002
NPT gland conduit entries.
• 120 degree horizontal field-of-view 70991 Meggitt Avionics swivel bracket in stainless
The Omniguard 660 and 860 Series Flame • 0 to 20 mA output & Relay contacts rated at 2
Detectors are optically based, self-contained, steel. For use with Stainless Steel body detectors
Amps @ 30 Vd.c. (Resistive).
microprocessor controlled, ultraviolet/infrared Technical Specification 517.060.003
(UV/IR) and high-speed ultraviolet (UV) flame Operating Temperature: -40°F to 185°F 540 Model 540 hand held UV/IR test gun for use
detectors. The S860 Flame Detector utilises the (-40°C to 85°C) with 860 Series detectors
patented Fire Event Analysis (FEA)™
Storage Temperature: -85°F to 212°F 517.060.005
discrimination technology. All electronics are
(-65°C to 100°C). Airshield for Omniguard S660 and S860 Flame
housed within a copper-free aluminum, high
temperature, TGIC-Polyester coated enclosure detectors
with a 3/4-14NPT entry. A stainless steel Datasheet - Product Code PSF103 “S860 UV IR
enclosure is also available. Flame Detector” and PSF104 “S660 UV IR Flame
Detector”

Page 58
tyco Fire & Tyco Electronic
Security Product Group
Intrinsically Safe Point Detectors
Features Technical Specification - M300/500Ex (Including base)
• Conventional and addressable I.S. systems
• Suitable for worst case (EEx ia IIC T5) MF300/MF500 MR300/MR500 MD300/MD500 MS300/MS500
• Tyco High Performance Optical (HPO) smoke
detector Dimensions 102.6Dia x 90H 102.6Dia x 96H 102.6Dia x 89H 102.6Dia x 74.5H
• Compatible with S231i+ plus flame detector Weight 0.3Kg/0.33Kg 0.3Kg/0.33Kg 0.28Kg/0.30Kg 0.275Kg
• Compatible range of I.S. callpoints Temperature -20oC to +70oC -20oC to +70oC -20oC to +70oC -10oC to +60oC
The System Designer must be familiar with Humidity 95% Non-condensing
BS5345, EN50 and BASEEFA certification and
have successfully completed an Appropriate M300 BASEEFA Cert. No.: EX88B2168X
recognised course in Intrinsic Safety. Design of M500 BASEEFA Cert. No.: EX89C2200X
the system requires that the designer has all the
MR301Ex, MR301TEx, MR300Ex base are CSA Approved Certificate No.: 2017002500004454
information concerning the installation correctly
documented. The nature of the Hazard must be BASEEFA certification designated for each There are two I.S. systems used by Tyco
defined by the customer and a survey carried out system it is essential that the certified devices are Electronic Product Group,
to determine the proximity of the safe area to connected with cables of the specified limits. System 601 and System 602
establish cable runs. These limits have been certified for specific
System 601 is for use in conventional fire
classifications of hazard in order that energy
The probability of a flammable mixture being detection circuits, and System 602 is for use with
storage is limited.
present is defined by a Zone Number. Flammable MINERVA analogue addressable circuits. Two
gases are classified in Groups and their minimum The number of devices connected to the barrier Sounder Systems, (one earthed and one isolated),
spontaneous ignition temperature is categorised and located in the Hazardous Area must always are available and either can be used with System
by Class. TEPG supplied equipment marked EEx be limited to not more than the listed maximum. 601 or System 602.
ia IIc T5 would be suitable for use in worst case When a mixture of devices is connected to any
conditions. Eg. Zone 0 (ia), Hydrogen (IIc), T5 one zone the numbers must be reduced in
Datasheet - Product Code PSF64 “Series
(100 deg C). The Fire Alarm Equipment and proportion to the ratio of the load presented to the
300/400/500 Fire and Smoke Detectors”
Safety Barriers should be placed as near as barrier. When a System includes the use of either
possible to the containment wall of the Hazardous IF500Ex, S231i+ or S251i+, it must be Manual - Vol01A* “Detectors Fire Manual”
Area. This minimises the cable lengths between remembered that the load they present to the * Section is indicated next to the product code.
the barrier and the Hazardous Area and thus the circuit is twice that of a detector. A mixture of
capacity to store energy. large and small load devices connected to a zone
In order that an Installation will comply with the will require a calculation for the number of allowed
detectors.

Ion Chamber Smoke Detectors


The ion chamber detector [type MF301Ex. Product Codes
MF501Ex] will respond very quickly to smoke 516.020.003 (Vol01A-02-D3)
composed of very small particles - even those
MF301Ex Ion Chamber smoke detector
invisible to the naked eye but may respond
appreciably slower to dense smoke composed of 516.030.002 (Vol01A-03-D3)
large particles. MF501Ex Analogue Addressable Ion Chamber
smoke detector

High Performance Optical Smoke Detectors


The MR301TEx and MR501TEx have been Product Codes
developed to overcome the slower response of 516.021.008 (Vol01A-02-D5)
the optical detectors to hot burning fires, by
MR301TEX High Performance Optical smoke
increasing the sensitivity of the optical detector
detector
when it is associated with a rapid change in
temperature. In this way it is intended to become 516.031.005 (Vol01A-03-D4)
a detector which can cover some of the risks MR501TEx Analogue Addressable High
currently covered by ion chamber detectors. Performance Optical smoke detector
Smoke detectors will not detect burning alcohol or
other clean-burning liquids which do not generate
smoke particles.

Optical Smoke Detectors


The photoelectric scatter type of detector Product Codes
[MR301Ex, MR501Ex] will respond quickly to 516.021.003 (Vol01A-02-D4)
large particle smoke and possibly ignore the small
MR301Ex Optical smoke detector
particle smoke. In the majority of cases, however,
the particle sizes are such as to permit the use of 516.031.002 (Vol01A-03-D4)
either type of detector. MR501Ex Analogue Addressable Optical Smoke
Detector

Page 59
tyco Fire & Tyco Electronic
Security Product Group
Heat Detectors
though less sensitive,alternative. For general use, the optimum response can be chosen for each
and particularly where the ambient temperature application.
may be low, a 'Rate-of-Rise' heat sensor is to be Product Codes
preferred. This type of sensor reacts to
516.023.002 (Vol01A-02-D7)
abnormally high rates of change of temperature
and provides the fastest response over a wide MD301Ex Grade 1 Rate of rise heat detector
range of ambient temperatures. A fixed 516.023.004 (Vol01A-02-D7)
temperature limit is also incorporated in these MD303Ex Grade 3 Rate of rise heat detector
detectors.
516.023.006 (Vol01A-02-D7)
In many environments, e.g. kitchens and boiler
MD305Ex Temperature range 2 heat detector
rooms, sudden, large changes in temperature are
considered 'normal'. Rate-of-rise detectors are 516.033.002 (Vol01A-03-D6)
generally not suitable in these cases and fixed MD501Ex Analogue Addressable Heat detector
If environmental conditions rule out the use of temperature [static] types should be used. Within
smoke detectors, then a heat detector of the type the broad classifications of 'rate-of-rise' and 'static'
MD300Ex Range may provide an acceptable, the MD300 range offers several versions so that

Flame Detectors
without sacrificing speed of response to flaming Product Codes
fires. In order to ensure full coverage, however, 516.022.001 (Vol01A-02-D6)
flame detectors do require direct line of sight to all
MS302Ex Infra-red flame detector
parts of the protected area.
(See S100 Flame detector test equipment)
Infra-red flame detectors such as the MS302Ex
and MS501Ex are designed to respond rapidly to 516.032.001 (Vol01A-03-D5)
fires which involve clean-burning fuels such as MS502Ex Addressable Infra-red flame detector
alcohol or methane, i.e. fires which would not be (See S100 flame detector test equipment)
detected by smoke detectors. The MS302Ex and
MS501Ex Flame Sensor, by virtue of its operating
wavelength and flicker discrimination, are
insensitive to normal environmental influences.
For outdoor use however, or in the presence of
Flame detectors, unlike smoke and heat
very strong infra-red sources, a solar-blind
detectors, do not rely on convection to transport
detector [e.g. the type S200Plus] should be used.
the fire products to the detector nor do they rely
The MS302Ex and MS502Ex Flame detectors
on a ceiling to trap the products. They can,
should, normally, only be used inside buildings to
therefore, be used to protect large open areas
supplement heat and smoke detectors.

M3/500Ex Detector Bases and Ancillaries


Product Codes 517.035.006
517.025.002 M500 Protective cover
M300Ex Mounting base 517.001.231
517.035.002 DHM69 Deckhead mounting kit. This deckhead
M500Ex Mounting base mounting is also suitable for 300/500 series
detectors.
517.025.010
517.001.120
M300/M500 Base lock kit
System 601 EOL Unit (P-10)
517.025.022
MB35 Flush mounting kit for M300/400/500 series

Olsen T54B - Point Type Heat Detector


Classified as a simple device, the T54B can be Product Codes
used in Zone 0 areas when connected to a 516.033.011
suitable intrinsically safe barrier. For reliable
T4E60X T54B Point Type heat detector - 60oC
operation, it is recommended that T54B detectors
have set points 20oC or 20% (whichever is higher) 516.033.012
above the maximum temperature they will be T4E90X T54B Point Type heat detector - 90oC
exposed to in normal operation. 516.033.013
Preferred factory preset temperatures are: T4E100X T54B Point Type heat detector - 100oC
60, 90, 100, 145oC; normally with open contacts. 516.033.014
Technical Specification T4E145X T54B Point Type heat detector - 145oC
Operating voltage @ 0.5A: 240Va.c. to Other temperatures and normally closed contacts
Constructed from stainless steel, the T54B is an 24Vd.c. are available by request.
extremely rugged heat detector that can be used
Switching Current: 5 to 500mA 514.001.017
to detect fires in the harshest of environments.
The T54B can be used in environments with Contact Resistance: <1 ohm IF500Ex Intrinsically safe addressable interface
ambient temperatures up to 200oC and, being Actuating Temp.:(factory set) 60 to 240oC suitable for T54B probes
hermetically sealed, is impervious to most Fixed Temp. Only: *Type E
contaminants. Datasheet - Product Code PSF24 “System
Accuracy: + or - 5%
The T54B is suitable for use in areas with 601/602 for Hazardous Areas”
Ambient Temp.: -40 to +270oC
explosive atmospheres. Certified as a flameproof
(Ex d) device, it can be used in Zone 1 and Zone Relative Humidity: 100% RH
2 hazardous areas when installed using Protection Category: IP67
flameproof mounting enclosures and conduit. Thread Size: M20 x 1.5mm

Page 60
tyco Fire & Tyco Electronic
Security Product Group
H Series Heat Detectors
• Special versions can be used in any Zone 1 or 516.014.021
Zone 2 environment H601 60oC Fixed temp. Grade 1 (Remote LED
• Grade 3 to European Standard EN54 Part 5 Ind.)
1977
516.014.019
Technical Specification
H602 60oC Fixed temp. Grade 1 (Integral LED
Operating Voltage: up to 24V d.c.
Ind.)
Quiescent Current: zero
516.014.025
Alarm Current: Limited by internal 390 ohm
H604 60oC Fixed temp. Grade 1 (Integral LED
or 50 ohm resistor
Ind.) Intrinsically Safe - Simple Apparatus
Dimensions: 82mm dia x 41mm
516.014.018
Weight: 73gm
The and H900 range of fixed temperature heat H900 90oC Fixed temp. Grade 1
detectors are designed to operate at 60oC and Material: Cycolac ABS
516.014.020
90oC respectively. They are particularly suited to Operating temp. range: -20oC to +100oC
H902 90oC Fixed temp. Grade 1 (Integral LED
areas where rapid changes in temperature and/or Relative Humidity: up to 100% RH (Non Ind.)
high ambient temperature exist, together with Condensing)
unsuitable environmental conditions for smoke 516.014.025
Alarm Temp: H6XX: 60oC
detectors. This makes the detectors ideally suited H904 90oC Fixed temp. Grade 1 (Integral LED
for galleys, laundries etc. H9XX: 90oC Ind.) Intrinsically safe - Simple Apparatus
Features Product Codes
• Approved by Marine classification authorities 517.001.130 Datasheet - Product Code PSF108 “H Series
• Two wire supervised circuit DHM8 (including 2 x 20mm glands) Fixed Temperature Detectors”
• Draws no quiescent current 516.014.017
• Self re-setting H600 60oC Fixed temp. Grade 1

SM87BG/CP530 Explosion Proof Addressable Callpoint


The SM87BG/CP530 is based on the popular Entries: 1 x M20 ISO right hand side
MEDC SM87BG explosion proof EEx ‘d’ callpoint plus 1 x M20 ISO left hand
break glass and is BASEEFA approved under the side
Tyco brand name with an integral CP530 Text: FIRE - BREAK GLASS
addressable callpoint module suitable for use on
Finish: Red Epoxy Paint
all MINERVA 8,16E and 80 analogue addressable
systems. Tag label: None fitted as standard
Technical Specification NOTE: Stainless steel option available, contact
Product Management Department, Sunbury for
MEDC Reference: SM87BGLAD1R1L0NR
more details.
Material: LM25TF Marine Grade Alloy
Product Code
Certification: EExd IIC T6
514.001.055
IP rating: IP67 EExd MEDC SM87BG heavy duty alloy
BASEEFA No.: SM87 ADDRESSABLE breakglass with integral CP530 potted
UNIT C (A) Ex85B1037 addressable module
Weight: 2.7kg 514.001.056
Spare glass and ‘O’ ring assembly for SM87BG
Dimensions: 122H x 122W x 105D mm
Mounting Holes: 4 x 9mm diameter (105 x
105mm centres)

Page 61
tyco Fire & Tyco Electronic
Security Product Group
Intrinsically Safe Callpoints
A variety of Ex ‘ia’ Intrinsically safe callpoints are The IF500Ex is an Intrinsically safe addressable the CP540Ex is specifically designed for use with
available as standard using KAC and MEDC interface module. the IF500Ex. The IF500Ex is fitted inside the
callpoint housings. It can be used to interface simple apparatus to CP950Ex and the IF520Ex and BASEEFA
The CP220Ex is a conventional callpoint for use MINERVA analogue addressable systems, Certified as integrated units.
on BASEEFA Certified System 601. System 601 designed to BASEEFA Certified System 602.
is compatible with MINERVA 1 to 4, System 1700, The IF500Ex can interface to devices such as ‘H’
NT & MINERVA Addressable DM modules. Series detectors & T54B heat probes. In addition

CP220Ex CP540Ex CP950Ex IF520Ex IF500Ex


Dimensions(H x W x Dmm) 87 x 87 x 51.5 87 x 87 x 51.5 126 x 120 x 118 122 x 122 x 118 122 x 120 90
Weight 200g 200g 1.2Kg 4.1Kg 900g
Material Polycarbonate Polycarbonate Polyester Stainless Steel Polyester
Conventional Yes No No No No
Addressable No Requires IF500Ex Yes Yes Yes
Colour Red Red Red Red Grey
BASEEFA Cert. Simple Apparatus Simple Apparatus 89C2202 89C2202 89C2202
IP Rating IP67 IP67 IP66 & 67 IP66 & 67 IP67
Note: Variants are available on request
Datasheet - Product Code PSF24 “System 601/602 for Hazardous Areas”
Manual - Vol08A-02-D11/D31/D32 “Ancillaries Manual”

514.001.009 514.001.023 514.001.017


CP220Ex Red Callpoint intrinsically safe for use CP540Ex Red callpoint intrinsically safe for use IF500Ex Intrinsically safe addressable interface
with BASEEFA certified conventional system 601. with IF500Ex. English ‘Fire’ marking and Thorn module. May be used to interface simple
English ‘Fire’ marking and Thorn Security branded Security branded lid. Simple apparatus marking apparatus switch callpoint to MINERVA analogue
lid. Simple apparatus marking addressable system. For use on BASEEFA
certified System 602

Product Code
515.001.041
Spare key for IF520Ex callpoint and other
SM87PB models
517.001.120
System 601 EOL Unit (P-10)

514.001.052 514.001.053
CP950Ex MEDC weatherproof intrinsically safe IF520Ex EExia MEDC SM87PB Stainless steel
callpoint with integral analogue addressable heavy duty intrinsically safe callpoint push button
module with integral IF500Ex analogue addressable
module

Page 62
tyco Fire & Tyco Electronic
Security Product Group
Intrinsically Safe Barriers and Housings
The following section relates to a range of intrinsically safe barrier and isolator equipment for use with Tyco Electronic Product Group manufactured fire
detection systems. It essentially encompasses the relevant MTL 5000 and MTL 7000 series barriers plus the associated housing options as an alternative to
existing MTL 700 and MTL 3000 series equipment.
On all issues of intrinsically safe systems design, please refer to Manual 26A for guidance.
Datasheet - Product Code PSF24 “System 601/602 for Hazardous Areas”
Manual - Vol026A-02-D1 “Intrinsically Safe Systems 601 & 602 Manual”

Galvanic Barriers
MTL 5000
The MTL 5061 is a two channel interface for use When designing new systems or upgrading
with conventional fire and smoke detectors existing MTL 3000 series systems to MTL 5000
located in hazardous areas. This galvanic isolator series, please use the appropriate MTL “DX”
is CE marked, and replaces the MTL 3043 barrier series enclosure equipment.
option. It is suitable for connecting loads in Zone Product Codes
0, IIC, T4-6 hazardous areas if suitably certified.
517.001.244
The MTL 5021 Isolating sounder driver enables
MTL 5061 2 channel galvanic isolator for
an intrinsically safe sounder device located in the
conventional detector zone - used on BASEEFA
hazardous area, to be controlled from the safe
Approved System 601
area. The MTL 5021 barrier is designed as a CE
marked replacement for the existing MTL 3021 517.001.245
barrier. It has one channel and is suitable for MTL 5021 I.S. Sounder driver
connecting loads in Zone 0, IIC, T4-6 hazardous
area if suitably certified.

MTL 3000
The MTL3000 series interface units offer a S100 series, S231i+ ) automatic fire detectors and
compact and easy-to-use means for the CP220Ex intrinsically safe callpoints. The
communicating safely with conventional fire MTL3043 is not suitable for use with addressable
detectors and output devices in the hazardous fire detectors. For application guidance, refer to
area. The MTL3000 solution provides an the relevant documentation for system 601 and
alternative to the shunt-diode safety barrier where system 602.
isolation is essential or preferred or a high Product Codes
integrity earth is not readily available.
517.001.204
The MTL 3021 enables the intrinsically safe
SYS.601/602 MTL3043 Galvanic Isolation safety
sounder type IS28 (576.501.013) to be activated
barrier
from the safe area. An absolute maximum of 4 off
I.S28 sounders may be connected to each 517.001.203
MTL3021 unit. SYS.601/602 MTL3021 Galvanic Isolation safety
The MTL 3043 is used primarily with intrinsically barrier
safe conventional type (M300 series, H600 series,

Zener Barriers
MTL 7100
The MTL 7100 Series intrinsically safe shunt- during commissioning, maintenance and fault
diode safety barriers are innovative devices finding, thus avoiding the need for additional
designed to provide exceptionally high packing disconnect terminals.
densities, straightforward installation and Please note that this barrier is a direct alternative
simplified connection, commissioning and for the MTL 728+ barrier. Currently, there is no
maintenance facilities. The MTL 7100 Series direct alternative for the MTL 788+ barrier used
include secondary replaceable fuses. These are with the MINERVA addressable system. So
useful where there is the possibility of faults addressable MINERVA systems must use the
occurring during commissioning, which would existing MTL 788+ barrier and associated housing
otherwise blow the barriers’ internal safety fuses. option.
One secondary replaceable fuse for each barrier Product Code
channel is provided and is lower in value than the
517.001.246
safety related fuse. Fuses are packaged in small
mouldings which can be latched in a disconnect MTL 7128+ Zener safety barrier for conventional
position to break the safe and hazardous areas detection circuits designed in accordance with
System 601

MTL 700
The MTL700 series are 1 or 2 channel devices Product Codes
which pass the electrical signal from fire detectors 517.001.201
to the control panel or from the control panel to
SYS.601/602 MTL728 Single Channel Zener
the output device. The barriers limit the amount of
Safety Barrier.
energy to a level that cannot ignite explosive
atmospheres. The over-voltage protection 517.001.202
provided by a Shunt-Diode Safety Barrier is with SYS.601/602 MTL788 Dual Channel Zener Safety
reference to the safety barrier earth connection. It Barrier.
is therefore imperative that a HIGH INTEGRITY 546.004.005
EARTH is used for this type of barrier.
SYS601/602 Intrinsically safe sounder circuit
interface module

Page 63
tyco Fire & Tyco Electronic
Security Product Group
Safety Enclosures
DX Series Enclosures
The MTL ‘DX’ Series enclosure equipment is Product Codes
designed to house MTL 5000 isolating interfaces 517.001.248
and MTL 7000 series shunt diode safety barriers.
DX070 Enclosure MTL 5000/7000 series barriers
Enclosures are usually selected on the number of
units they will accommodate. The following table 517.001.247
shows the capacity of each of the enclosure DX170 Enclosure for MTL5000/7000 series
types. barriers
Enclosure MTL5000 Isolators 16mm Pitch MTL7000 Barriers 7.5mm Pitch
DX070 4 (2*) 9 (5*)
DX170 10 (8*) 22 (18*)

* Use these figures when two IMB57 mounting brackets for tagging/earth rail accessories are included

UC Series Enclosures
The UC series of enclosures provides a simple Product Code
but effective means of mounting and protecting 517.001.196
the MTL3000 series units, in safe areas. Two
SYS.601/602 UC2 4, Way Barrier housing
standard lightweight enclosures with transparent
lid are available, which can accommodate either 4
or 8 units. The polycarbonate enclosures are
impact resistant, flame retardant, and dustproof to
IP65.

MT Series Enclosures
The MT series of enclosures provides a simple, Product Codes
effective means of mounting and protecting 517.001.198
MTL700 Series barriers in safe areas or low-risk
SYS.601/602 MT2 2,Way Zener Barrier Housing.
hazardous areas. Three lightweight polycarbonate
enclosures with see through lids accommodate up 517.001.199
to 2, 5 and 12 barriers in the safe area. All the SYS.601/602 MT5 5,Way Zener Barrier Housing.
enclosures are supplied ready fitted with a nickel 517.001.200
plated brass busbar mount, so barriers can be
SYS.601/602 MT12 12,Way Zener Barrier
installed and wired up immediately without special
Housing
tools.

Ancillaries
The ERL7 earth rail is a nickel plated 3 x 10mm Product Codes
rail (1 metre long), suitable for a do-it-your self 517.001.205
mounting arrangement. It will accommodate up to
SY.601/602 ERL7 Earth rail I.S. systems
2.5 ETM7 earth terminals per barrier location for
terminating earth returns and cable screens from 517.001.206
the hazardous area. SY.601/602 ETM7 Earth termination connection
The EBB7 earth busbar is nickle plated brass, and system
ready drilled for MTL700 series devices, and in 1 517.001.207
metre lengths. The IMB7 mounts on a flat surface SY.601/602 IMB7 Insulating mounting block
or top hat rail (35mm) or G-profile rail and acts as
517.001.216
a convenient method for mounting the earth
busbar. SY.601/602 EBB7 Earth bus bar
517.001.120
System 601 EOL Unit (P-10)

Page 64
tyco Fire & Tyco Electronic
Security Product Group
Beam and Linear Heat Detectors
Technical Specification Voltage Range- Fireray 2000 +11.5 to +28Vd.c.
Dimensions(mm) Weight LPBD521 28V Loop Power
Height Width Depth (Kg) Fireray 2000 Quiescent Current <13mA
Transmitter/Receiver 95 75 115 0.4 Fireray 2000 Alarm Current <20mA
Control Unit 260 210 80 2.25 Operating Temp. Range - Fireray -10oC to +55oC
LPBD521 (with M520 encl.) 87 148 14 0.1 LPBD521 -20oC to +70oC
Humidity up to 95% RH
(Fireray 2000 & LPBD521) (Non-condensing)
Fireray 2000 Enclosure IP54

Optical Beam Smoke Detectors


• Selectable sensitivity 920450
• Self-check and automatic compensation FireRay2000 -UL Fireray 2000 Optical beam
• Manual or automatic reset smoke detector complete- UL approved
• Optional MINERVA loop powered interface
516.015.007
module (LPBD520)
• Suitable for both conventional and addressable FireRay2000 Retro-Reflector 100 x100mm
fire systems 516.015.008
• Fire/fault interface to MINERVA controller FireRay2000 Alignment tool
• Low current consumption
Spares
• Flexible system design options
• Robust metal construction 515484
• Designed to conform to BS5839 Part 5 FireRay2000 Spare Transmitter
The FIRE-RAY 2000 is an active infra-red smoke Product Codes 515485
detector. The system comprises of three base 516.015.006.A FireRay2000 Spare Receiver
elements i.e. a transmitter, receiver and Control
FireRay2000 optical beam smoke detector 515487
Unit. Analysis of the modulated infra-red beam by
the Control Unit determines whether smoke is VdS approved, ADT Branded FireRay2000 Spare Main PCB
present, and if so generates an alarm signal. 516.015.006.T
Features FireRay2000 optical beam smoke detector Datasheet - Product Code PSF85 “Fireray 2000
• Range 5 metres up to 100 metres VdS approved, Thorn Branded Optical Beam Smoke Detectors”
• Area coverage up to 1400m2 Manual - Vol08A-02-D26 “Ancillaries Manual”

LPBD521 - Loop Powered Beam Detectors


MINERVA loop. A single LPBD521 can be used to Operating Humidity up to 95% RH non-
power the analyser unit, the beam receiver unit condensing
and the transmitter unit. Alternatively, two Dimensions (PCB): 60H x 84W x 14D mm
separate LPBD521's can be used with one to
Product Code
power the analyser unit and receiver units and the
second to drive the transmitter separately, either 557.180.217
from the same loop or a different loop. Up to 8 LPBD521 loop powered beam detector interface
LPBD521's can be used per loop. module for use with FireRay 2000
The module is addressable and will therefore take
one address on the loop. Datasheet - Product Code PSF85 “Fireray 2000
Technical Specification Optical Beam Smoke Detectors”
Powered: Loop Manual - Vol08A-02-D22 “Ancillaries Manual”
The LPBD521 module is used to drive the FireRay Temperature Range: -20oC to 70oC
2000 beam detector units directly from the

Linear Heat Detection


Features Product Codes
• Easy and cost effective installation 516.016.005
• Good sensitivity with adjustable alarm LD40 High resistance sensor cable blue - 200M
threshold reel
• Open and short circuit monitoring 516.016.006
• Suited for outdoor and indoor applications
LD40 High resistance sensor cable black - 200M
• Can be used in hazardous areas reel (Nylon sheath suitable for petrochemical
• Mechanical protection is provided for cables in exposure)
areas where damage may occur
516.016.007
• Chemical resistance sheathing is available for
areas where petro-chemical corrosion may LD40 High resistance sensor cable bronze
occur. braided - 200M reel - suitable for situations where
Technical Specification the cable is exposed to friction
Dimensions: 170H x 105W x 111D mm 516.016.010
The LD40 linear heat detection system is used to
Weight: 0.55Kg LD40 EOL Termination kit
monitor fire (or overheat) conditions in confined or
Operating Temp.: -25oC to +70oC 516.016.011
polluted areas or where there are adverse or
Relative humidity: Up to 98% RH non- LD40 In-line jointing kit
unusually variable environmental conditions. The
condensing
sensor cable is unaffected by dust, moisture or 516.016.012
Rating: IP55
vibration and requires little maintenance. LD40 Analyser module with conventional
Operating Voltage: +8 to 30Vd.c.
Quiescent Current: 60-80µA detection zone interface. Requires a DM520 or
similar zone module interface to MINERVA/TFX
addressable loops

Datasheet - Product Code PSF42 “LD40 Linear


Heat Detection System”

Page 65
tyco Fire & Tyco Electronic
Security Product Group
MXF Optical Fibre Temperature Sensing
Features Technical Specification
The MXF100 system complies with:
• Fibre optic sensor loop up to 2km • EMC Directive 89/336/EEC
• Continuous temperature profiles of • Low Voltage Directive 72/2/EEC
temperature on a PC The MXF100 contains a Class 3a Laser product
• Programmable functions and complies with:
• BS7192 (1989)
• Programmable number of fire detection zones • American National Standard Z136.2 (1988)
• Multiple and programmable Alarm levels per • International Electrotechnical Commission
fire detection zone Standard 825 (1990)
• Variable rate of rise function Dimensions: 260H x 427W x 95D mm
Weight: 4.0Kg
• Unrivalled response times
This new technology uses a laser light source to Supply Voltage: 24V d.c. (-6/+12V d.c.)
launch light signals into the optical fibre. As • Optional outputs Power Consumption: 20W max
pulses travel down the fibre, energy is lost through • Modbus Serial Data Supply Current: <1A
scattering. A fraction of the scattered signal is Fuse Rating: <2A (anti-surge)
retained within the fibre. A portion of this is • Direct to PC
Fibre: 62.5/125 graded index multi-
directed back along the fibre towards the laser mode
• Volt free contacts
source - this signal is called backscatter. Part of
Operating Temp.: 0oC to +40oC
the back scatter signal (Raman Scattering) is • Insensitive to EMI
used to provide accurate remote temperature Storage Temp.: -40oC to +65oC
• Intrinsically safe sensor Humidity: 0 to 95% RH (non-
measurements at hundreds of points along the
fibre. • Uses standard communications grade optical condensing)
The MXF100 uses standard communications fibre Product Codes
grade optical fibre of the 62.5/125 graded index 516.016.101
• Choice of cable construction
multimode type. The temperature range is MXF100 Fibre Optic Linear Heat Detection control
predominantly a function of the coating used to • Cable construction for extreme environments unit
protect the optical fibre as the fibre itself is well 516.016.102
• High System Integrity
behaved over a temperature range from -50oC to MXF-ACS 62.5/125 single strand acrylate coated
approximately 300oC. Coatings have been tested • Automatic failure mode analysis multi-mode fibre 1Km reel
down to -190oC (acrylate) and up to 460oC
• Loop break recovery operation 516.016.103
(metallic).
MXF-ACS 62.5/125 single strand ribbon/dog-bone
Optical fibre itself offers several advantages as a • Diagnostic capability acrylate coated multi-mode fibre 1Km reel
sensing medium. The signals are immune to
• Fire progression monitoring Stainless steel clad fibre also available.
electromagnetic interference thereby ensuring
integrity of readings from electrically noisy areas. • No cable maintenance 516.016.104
As no electrical current is used in the sensing MXF-SSS 62.5/125 Single strand, stainless steel,
fibre and the fibre is relatively inert and dielectric • Modem for remote communications 316L sheath, multimode fibre 1Km reel
(non-conducting) medium, it is safe technology to
use in hazardous environments. Datasheet - Product Code PSF111 “MXF100
Optical Fibre Temperature Sensing Technology”

MXF100 FUNCTIONAL BLOCK DIAGRAM

INTERNAL FIBRE LASER &


REFERENCE SWITCH RECEIVER

OPTICS
CONTROL

OPTICS

SIGNAL CONTROL

RELAY PCB1
POWER DATA
SUPPLY ACQUISITION
RELAY PCB2

RELAY PCB3
POWER SIGNAL

DATA
PROCESSOR

ELECTRONICS

RS232 PORT 1 RS232 PORT 2 MODBUS


24Vd.c. RELAY CONNECTORS TO PC OR SERIAL DATA

Page 66
tyco Fire & Tyco Electronic
Security Product Group
Detector Test Equipment
Point Detector Testing/Commissioning Equipment
Manual - Vol01A & Vol01B “Detectors Manual”

Product Codes
517.001.230
SOLO100 Telescopic pole 1.26M to 4.5M long
517.001.226
SOLO101 Extension tube 1.3M long for use with
517.001.230 telescopic pole Product Code Product Codes
517.001.228 517.001.225 517.001.241
SOLO600 Carry all bag for detector test kit SOLO302 Aerosol dispenser for use with all SOLO451 Cordless heat detector tester kit
detector ranges. Connects directly to including SOLO450 tester, SOLO720 battery
SOLO100/101 poles batons and SOLO721 charger. Connects directly
to SOLO100/101 poles
517.001.242
SOLO720 Spare battery baton for use with
SOLO450 tester
517.001.243
SOLO721 Spare mains/car battery charger for
SOLO720 battery baton

Product Code Product Codes Product Codes


517.001.229 517.050.004 517.001.233
Suretest Solo aerosol tester can. For use with M69 Detector changer for use with M600/M900 MU TEST CO Detector field test kit with 24
Solo 302 dispenser. Non-flammable, ozone and series. Requires Adaptor B and Solo 100 pole brickets for use with Solo 302
environment friendly. Approx 200 tests per can 515478 517.001.234
M69 Detector changer (Grinnell) CO Fire detector field test kit spare bricks
(Pack of 24)

Product Code Product Code Product Code


517.025.026 517.001.224 517.001.240
T35 Skirt changer tool for use with M300/400/500 SOLO704 Adaptor tube B - Adapts SOLO100/101 SOLO200 Universal detector changer for use with
series requires Adaptor B and SOLO100 pole pole sets for TYCO detector changers and testers various manufacturers detectors - not suitable for
M600/900 series low profile. Connects directly to
SOLO100/101 poles

Page 67
tyco Fire & Tyco Electronic
Security Product Group
SOLO TEST EQUIPMENT FOR POINT & FLAME DETECTORS

S111/112/121/122
S131/161 MS300/500 S200+
517.001.233
TEST CO & SMOKE DETECTORS
517.001.229
592.001.014
FPA18 AEROSOL
592.001.007 592.001.004 592.001.005 T210 517.025.026 DISPENSER
ADAPTOR TYPE 35 SKIRT 517.130.007
T110 TRS SURVEY CUP
ADAPTORS CHANGER HEAD
517.130.008
592.001.013 517.050.004 DETECTOR CHANGER HEAD
T210 M69 DETECTOR
CHANGER 517.001.225 517.001.032
592.001.012
T110 SOLO302 SOLO704
AEROSOL ADAPTOR TUBE D
DISPENSER

517.001.224
SOLO704
ADAPTOR TUBE B

517.001.226
SOLO101 EXTENSION
POLE 1.13m

517.001.230
SOLO100 TELESCOPIC
EXTENSION POLE SET
1.26m TO 1.45m

517.001.228
SOLO600 CARRYALL BAG

S200 Series Test Equipment


Intrinsically safe calibrated test sources for
M300/M500, S100 & S200 Series Flame detectors
in hazardous areas.

592.001.013 592.001.014
T210 Test source for use with (517.001.224) T210 Adaptor S200
SOLO 704 Adaptor Tube B and SOLO100/101
poles (517.001.230/226)

S100 Series Test Equipment

592.001.012 592.001.004 592.001.005


T110 Test Source for use with (517.001.224) T110 Adaptor plate for S111/112/121/122 (shown) T110 Adaptor for S131/161
SOLO704 adaptor tube B and SOLO100/101 592.001.007
poles (517.001.230/226)
T110 Adaptor for M300/500
592.001.010
T110 PP9 Battery and Charger kit
592.001.011
T110 Carrying case (not suitable for T210)

Page 68
tyco Fire & Tyco Electronic
Security Product Group
CP Series Callpoints
A comprehensive range of callpoints for use with addressable callpoints Datasheet - Product Code PSF36 “CP200 Series
both conventional and addressable systems. All • Test key facility, speed maintenance visits Break Glass Detectors”
the callpoints are designed to enable an alarm • Optional transparent hinged cover Manual - Vol08A-02-D9/D10/D27 “Ancillaries
signal to be given by breaking a glass element, • Hazardous areas models available (See Manual”
this operates a switch and is indicated by an LED Special Hazards Section)
indicator. If required, an optional transparent • IP66 Waterproof models for external
hinged cover may be installed to guard against applications
accidental operation. Technical Specification - (Indoor & Outdoor)
Features Housing: Modified Polyphenylene
• Integral LED indicator for easy identification of Oxide[Noryl SE100]
operation Operating Temp.: -20oC to +70oC
• Surface or flush mounting Relative Humidity: up to 95% RH (non-
• Extensive range of conventional and analogue condensing)
Commonly Used Callpoints
Model Colour Function Marking Type IP Range R1/R2 Ohms
CP200 Red Fire Conventional Alert 44 120/470
CP210 Red Fire Evacuate Conventional Evacuate 44 49/39
CP230 Red Fire Conventional Alert 66 120/470
CP270 Yellow Evacuate Conventional Evacuate 44 47/39
CP920 Red Fire Addressable 44 Not Applicable
CP930 Red Fire Addressable 66 Not Applicable
CP937 Red Fire Addressable 55 Not Applicable
Keyswitch White Bomb Alarm Conventional 44 Not Applicable

Callpoint Dimensions
Indoor Callpoint Outdoor Callpoint (IP66)
Weight: 200g Weight: 400g

87mm 51.5mm 124mm


87mm
Although the callpoint can 15mm
be fitted on a 16mm deep
box this leaves little room
for the conductors: A
25mm deep box minimum
is recommended.

Note: Contacts rated at 32Vdc @ 100mA 39mm


Red

59mm

Conventional Callpoints
Typical Conventional Wiring
Typically the conventional callpoint devices draw
no current in the ‘off’ state, but when activated, will
R2 R1 R2 R1 present an alarm load to the fire detection control
panel. The alarm load is defined by the internal
+ resistance arrangement for the device.
IN OUT

Addressable Callpoints Outdoor Callpoint (IP55)

Typical Addressable Wiring


Addressable callpoints contain an address unit
Loop enabling connection to the MINERVA Addressable
IN OUT range of fire controllers. The address unit includes
a custom chip and a 7-way DIL Switch which is
used to define the address of the callpoint.

- + - +

Black Red

Flying Leads
Callpoint

Page 69
tyco Fire & Tyco Electronic
Security Product Group
Conventional CP200 Callpoint
The CP200 is a red indoor callpoint with ‘alert’
resistors and LED indicator. The CP200 is LPCB
approved.
Product Codes
514.001.042.T
CP200 without backbox, English ‘Fire’ marking
and Thorn Security branded lid
514.001.042.Y
CP200 with backbox, English ‘Fire’ marking and
Tyco branded lid
514.001.057
CP200E without backbox, European ‘Fire’ marking
and glass, unbranded lid
90-110
Standard KAC KR-1 Flush Callpoint (No resistors
fitted)
514.001.042.A 514.001.006 70-133
CP200 without backbox, English ‘Fire’ marking CP200A complete with surface backbox. Arabic Standard KAC KR72-680 Flush Callpoint
and ADT branded lid English ‘Fire’ marking. Thorn Security branded (680 Ohms resistance)

Conventional CP210 Callpoint


The CP210 is a red indoor callpoint with ‘Fire
Evacuate’ marking, LED indicator and evacuate
resistors. The CP210 is LPCB approved and
supplied without backbox.
Product Codes
514.001.043.A
CP210 ADT branded
514.001.043.T
CP210 Thorn Security branded
514.001.043.Y
CP210 Tyco branded

Conventional CP230 Callpoint


The CP230 is an IP67 red weatherproof callpoint
with LED indicator and LPCB approved.
Product Codes
514.001.010.A
CP230 ADT branded
514.001.010.T
CP230 Thorn branded
514.001.010.Y
CP230 Tyco branded

Conventional CP270 Callpoint


Product Code
514.001.014
CP270 Yellow callpoint ‘Evacuate’ complete with
LED indicator without backbox - LPCB approved.
English ‘Fire evacuate’ marking

Other Conventional Callpoints & Keyswitches


Product Codes
514.002.002.A
White keyswitch in callpoint housing. English
‘Bomb Alert’ marking with ADT branded lid (see
picture)
514.002.002.T
White keyswitch in callpoint housing. English
‘Bomb Alert’ marking with Thorn Security branded
lid

Page 70
tyco Fire & Tyco Electronic
Security Product Group
CP920 MINERVA Addressable Callpoint
The CP920 is a red addressable callpoint with
‘Fire’ marking and LED indicator. The CP920 is
LPCB approved and supplied without backbox.
Product Codes
514.001.049.A
CP920 ADT branded
514.001.049.T
CP920 Thorn Security branded

CP930 MINERVA Addressable Callpoint


The CP930 is a red addressable IP67
weatherproof callpoint with ‘Fire’ marking and LED
indicator. The CP930 is LPCB approved.
Product Codes
514.001.050.A
CP930 ADT branded
514.001.050.T
CP930 Thorn Security branded
514.001.512
Addressable potted module used in the CP530
and CP930

CP937 MINERVA Addressable Callpoint


The CP937 is a red addressable IP55 outdoor
callpoint with the same functionality as the CP930.
the CP937 is based on the KAC Series 7000.
Product Codes
514.001.054.A
CP937 callpoint ADT branded
514.001.054.T
CP937 callpoint Thorn branded

Special Marine Callpoints


Product Codes 514.001.046 callpoint complete with LED indicator - Marine
514.001.012 CP520 Red addressable callpoint with LED approved. English ‘Fire’ marking and Thorn
CP260M Marine callpoint ‘Fire Alarm’ complete indicator without backbox - Marine approved Security branded lid
with LED indicator - IP67 English ‘Fire’ marking and Thorn Security branded
514.001.013 lid
CP250M Marine callpoint ‘Fire alarm’ complete 514.001.022
with LED indicator surface CP530 Red addressable IP67 weatherproof

Callpoint Ancillaries
Product Codes
90-106
Test keys for all CP200/500/900 callpoints except
CP950Ex

90-107 515.001.005
Red M141 spacer for red CP2/900 KAC callpoints Hammer on chain (for use with any breakglass
callpoints)

515.001.028 515.001.026
Callpoint hinged cover for use on CP200 and 900 Black callpoint bezel for CP200/500/900
models

Page 71
tyco Fire & Tyco Electronic
Security Product Group
STOPPER
The callpoint STOPPER provides protection from
malicious or accidental activation of manual
callpoints. Available for flush or surface mounted
callpoints the ‘STOPPER’ is also available with
optional high pitch sounder which is activated
when the lid is lifted.
An optional ‘Break-Seal’ fitting kit allows ‘Break-
Seals’ to be used to provide extra protection.
WARNING:-Break seals only to be fitted by
agreement with relevant fire authorities.
The STOPPER is suitable for all callpoints up to
100mm square, including CP820, CP920, CP200 Product Code
and other indoor KAC style callpoints. 515.001.033
IPO36 Break Seal Kit

STOPPER STOPPER II With Sounder Weatherproof


Product Code Ref Flush Surface
515.001.029 STI6530 ✔
515.001.030 STI6531 ✔
515.001.036 STI6535 ✔ ✔
515.001.034 STI1230 ✔
515.001.035 STI3150 ✔ ✔
515.001.031 STI6532 ✔ ✔
515.001.032 STI6533 ✔ ✔

STOPPER Dimensions

Millimeters
A 137
B 140
C 104
D 45
E 12.5
F 12.5
G 185
H 12.5

Flush Fit Surface Fit


(+30mm)
Stopper STI6530 STI6531
Stopper with Sounder STI6532 STI6533

STOPPER STOPPER II
Max. Callpoint Size 100 x 100mm 160 x 160 mm
STOPPER II Dimensions Max. Callpoint Depth 57.5 120
(+30mm Surface)

Millimeters
A 70
B 16
C 197
D 50
E 178
F 146
G 228
H 254
Stopper II Surface Fit - STI1230

Page 72
tyco Fire & Tyco Electronic
Security Product Group
STOPPER II
STOPPER II is constructed as the STOPPER from Product Code
tough injection moulded polycarbonate. Physically 515.001.034
larger than the STOPPER the STOPPER II STI1230 Surface fit STOPPER II
extends the number of products to which these
tough multi-purpose covers can protect.
It consists of a strong tamper-proof clear
polycarbonate cover and frame that fits easily
over such products as break glass callpoints. The
STOPPER II can also be fitted with an integral
battery powered sounder which activates if the
cover is lifted.
The STOPPER II is suitable for callpoints up to
160mm square like the DIN820/830 and CP830.

Weather STOPPER & Weather STOPPER II


The Weather STOPPER and Weather STOPPER
II extends the life of weather exposed devices,
such as break glass callpoints, by offering
protection against harsh conditions and
environments. Experience has shown that this
protective cover can extend the life of products
installed in saline atmospheres, such as oil rigs
and ship decks. While offering environmental
protection the Weather STOPPER and Weather
STOPPER II are constructed from tough durable
polycarbonate which will also guard against
tampering, vandalism or accidental operation of
devices such as emergency switches.
Product Codes
515.001.036
STI6535 Surface fit Weather STOPPER
515.001.035 STI3150
STI6535
STI3150 Surface fit Weather STOPPER II

Smoke Beam/CCTV Guard


The Smoke Beam/CCTV Guard is manufactured
from tough coated steel rod and is designed to
protect projected beam detectors or CCTV
cameras from vandalism or accidental damage.
Suitable for use with System Sensor, Hochiki and
Fireray 2000 detectors.
Technical Specification
Dimensions: 260H x 200W x 321D mm

Product Code
516.015.009
STI9625 Smoke beam/CCTV guard

Extinguisher STOPPER
The Extinguisher STOPPER is a self powered Product Codes
electronic security device which can be installed 515.001.038
and protecting fire extinguishers in minutes. The STI6200 Extinguisher STOPPER
Extinguisher STOPPER is an effective way to stop 515.001.042
vandalism, misuse or theft. This simple self STI6205 Operating cable kit
contained device incorporates a unique and
patented steel cable operated switch mechanism,
which activates a piercing alarm when the
extinguisher is removed from its normal position.
One end of the operating cable is crimped and
secured around the neck of the extinguisher and
inserted into the alarm unit. If the operating cable
is detached from the unit a 10dB sounder is
activated.

Exit STOPPER
The Exit STOPPER is a completely self contained are also options for remote and double door
and self powered security device to protect and installation.
deter the unauthorised use of emergency exit The unit comes complete with low battery
doors. It is a versatile, reliable and extremely easy warning, automatic reset facility, a choice of
to install electronic door alarm. If the door is steady pulsating tones, a 9V long life alkaline
opened the Exit STOPPER activates a 110dB battery and installation pack.
electronic sounder. A key operated over-ride
facility is incorporated into the front of the unit, Product Code
which will allow authorised use of the emergency 515.001.037
door. STI6400 Red Exit STOPPER
The Exit STOPPER is injection moulded in flame
retardant polycarbonate and can be easily
installed on wooden, glass or metal doors. There
Page 73
tyco Fire & Tyco Electronic
Security Product Group
Keybox
This tough polycarbonate breakglass keybox is
available to protect emergency keys and
documents.

Product Code
515.001.039
STI6720 Keybox with printed glass

Ancillaries - Back Boxes


Unless stated the CP200/500/900 indoor callpoints are supplied as flush mount units. The CP range are approved for use with the standard backbox.
However, SRT-2 and SRT-3 backboxes are also available.

515.001.021 10-115 95-131


Standard Red surface mounting back box for SR2-T Optional Back Box (2 terminals) SR3-T Optional Callpoint Back Box (3 terminals)
CP200/500 & 900 indoor callpoints

Callpoint Spare Glasses - Current


Product Codes
515.001.014
CP200/500/900 Spare glasses, white Arabic text
on clear background (Pack 5)
515.001.023
CP200/500/900 spare glasses for
CP200N/CP500N, white dutch text on clear
background (Pack 5)
515.001.027
Deformable operating unit “glass” with English text
for use in place of glasses, for kitchens or other
areas where glass is not acceptable 515.001.025 515.001.024
CP200/500/900 Glasses, clear English text on CP200/500/900 spare glasses, white
white background. No logo (Pack 5). Fitted as Arabic/English text with Thorn Security logo on
standard to English CP200/500 and 900 Callpoints white background (Pack 5)

Callpoint Spare Glasses - Old

90-108 515.001.003 515.001.009


Spare Instrum glasses for Simplex (Wormald ZF121 Callpoint glass (Pack 10) for service CP100A glass unscored (Pack 10) for services
Britannia) break glass spares. The ZF121 is a square metal fronted AFA spares. The CP100 has large square glass to the
MINERVA callpoint typically used on Firefinder, edge of the callpoint. Used on the same AFA
System 1100, ZF/System 1200, CP and CT systems as the ZF121.
systems

515.001.010
Walsall callpoint glasses (Pack 10) for services
spares. The Walsall callpoint is an old square
callpoint with round glass
Page 74
tyco Fire & Tyco Electronic
Security Product Group
MINERVA Range of Sounders
A range of sounders to meet a wide variety of Features • Weatherproof units for outdoor use
alarm applications where loud, penetrating and • Wide range of both bells and electronic • Distinct sounds are available
distinctive warning must be given to alert people sounders • Motorised and Solenoid bells available
of fire situations. In addition, multitone electronic • High sound output characteristics • Wide range of voltages available
sounders can give a variety of sounds to signal • Low current consumption • Addressable Loop Powered Banshee
other conditions e.g. “extinguishing gas release • Clean lines, modern styling
imminent”, etc. • Easy to install, low installation costs
Datasheet - Product Code PSF11 “Audible Alarms”

Sounder Type Weight Enclosure Current Sound Frequency Output


(Kg) to IP Consumption Output (Hz)
@24V d.c. db @ 1m
150mm 6” Solenoid Bell 1.3 IP20/44 50mA 91 Ringing A

150mm 6” Motorised Bell 0.7 IP22 15mA 94 Ringing A

200mm 8” Motorised Bell 1.4 IP22 30mA 95 Ringing A

Banshee LF 0.25 IP45/66 15mA 103 800-950 ABCD

Banshee HF 0.25 IP45/66 25mA 103 2500-3000 ABCD

Banshee Loop Powered* 0.30 IP45/66 See note below 100 800-950 B

Bedlam 0.30 IP66 30mA 113 2300-2900 ABCD

FM Bedroom Sounder 0.19 IP44 7mA 90 800-950 AB

Squashni Sounder 0.18 IP43 20mA 85 800-970 ABCD

YODALARM YO3 0.24 IP54 35mA 97 800-1000 ABE

YODALARM YO5 0.55 IP54 20mA 91 800-1000 ABE

YODALARM YO8 2.42 IP54 330mA 112 800-1000 ABE


A - Continuous *LPBB520 facility, no separate sounder circuit needs to be
B - Fast Sweep ie 9 times/sec The loop powered addressable sounder unit is a installed, providing significant cable installation
low frequency Banshee that can be both savings. The sounder output is set at a continuous
C - Slow Sweep ie 3 times/sec
controlled and powered via the MINERVA fast sweep (9 time/sec) but may be pulsed (alert
D - Buzz ie 120 times/sec signal) under the control of the MINERVA fire
analogue addressable fire controller. With this
E - Interrupted controller.

Bells
6” Red Solenoid Operated Friedland Bell
The bells are the underdome type, with a high with ADT branding
resonance pressed alloy-steel gong to ensure a 576.500.009.T
loud clear-tone ring. The operating mechanism is
24V Bell 6” 24V d.c. solenoid operated.‘Fire’ text
fully enclosed and the gong is red stove
with Thorn branding
enamelled for long life. The bells are designed for
internal use, but gasket sealed conduit boxes can 577.001.002
be provided for external use. BELL WP BOX Weatherproof gasket box 6” for
Product Codes use with Solenoid operated bells
576.500.004.A
240V Red bell 6” 240Va.c. solenoid operated.
‘Fire’ text with ADT branding
576.500.004.T
240V Red bell 6” 240Va.c. solenoid operated.
‘Fire’ text with Thorn branding
576.500.009.A
24V Bell 6” 24V d.c. solenoid operated. ‘Fire’ text

Motorised Bells
Features Product Codes
• CE marked 576.501.039.A
• Low current 6” bell (ONLY 15MA) MBF-6WE ADT Branded
• Low cost
• Extra high 94dBA/m 576.501.039.T
• Slim profile (53mm) MBF-6WE Thorn Branded
• Fully suppressed and polarised 576.501.040.T
• Quick and easy to install MBF-8WE Thorn Branded
Model MBF-6WE MBF-8WE
576.501.040.A
Rated Voltage 24V d.c. 24V d.c.
MBF-8WE ADT Branded
Rated Current 15mA 30mA
Other branding available on request
Sound output 94dBA 95dBA
Operating Temp -10 to +50°C
Colour Red
Weight 720g 1420g
Page 75
tyco Fire & Tyco Electronic
Security Product Group
Electronic Sounders
Banshee/Bedlam
An ultra low profile alarm sounder for fire and • Volume Control
security applications utilising all of the best • Side and Rear cable entry
features of the traditional Banshee plus an • Optional Deep base
additional volume control fitted as standard. The • Loop in out terminals
low profile unit has been designed to complement Sound Options:
new building interiors and is available in red or Buzz: Very fast sweep at approx 120Hz
white. Fast Sweep: 800Hz-950Hz, sweeping 9 /Sec
Features Slow sweep: 800Hz-950Hz, sweeping 3/Sec
• Ultra Low Profile Continuous: 850Hz
Product Code Branded Colour Power Freq dB Alarm Current Weatherproof
Banshee 576.501.004.A ADT Red 24V 800-950Hz 107 15mA No IP44
576.501.008.A ADT Red 24V 2.5-3KHz 105 25mA No IP44
576.501.033.A ADT White 24V 800-950Hz 107 15mA No IP44
576.501.024.A ADT Red 24V 800-950Hz 107 15mA Yes IP66
576.501.015.A ADT Red 24V 2.5-3KHz 117 30mA Yes IP66
576.501.004.T Thorn Red 24V 800-950Hz 107 15mA No IP44
576.501.008.T Thorn Red 24V 2.5-3KHz 105 25mA No IP44
576.501.033.T Thorn White 24V 800-950Hz 107 15mA No IP44
576.501.024.T Thorn Red 24V 800-950Hz 107 15mA Yes IP66
576.501.015.T Thorn Red 24V 2.5-3KHz 117 30mA Yes IP66
576.501.004.Y Tyco Red 24V 800-950Hz 107 15mA No IP44
576.501.033.Y Tyco White 24V 800-950Hz 107 15mA No IP44
Sound levels are quoted on E-SPL Effective Sound Pressure Level @1 Metre which is the output in a
typical room setting. 117dB models are known as Bedlam sounders
Weatherproof Banshee Line Powered Banshee
The LPBB521 Line powered Addressable is low frequency [800-950hz]. The Sounder
Sounder is designed to be driven from a Loop output is set to Fast Sweep, but may be pulsed
Powered MINERVA Analogue Addressable under the control of the MINERVA.
controller via the addressable loop. The sounder Quiescent Current: 0.52mA
Product Code Branded Colour Power Freq dB Alarm Current Weatherproof
577.001.026.A ADT Red Loop LF 100 17mA No IP44
577.001.029.A ADT White Loop LF 100 17mA No IP44
577.001.026.T Thorn Red Loop LF 100 17mA No IP44
577.001.029.T Thorn White Loop LF 100 17mA No IP44
577.001.026.Y Tyco Red Loop LF 100 17mA No IP44
577.001.029.Y Tyco White Loop LF 100 17mA No IP44

Accessories
The combined mounting bracket for the Besson Product Codes
Bedlam
Banshee and Xenon Beacon allows quick and 576.501.041
neat installation of combined sounders and
Banshee/Xenon bracket
beacons. The bracket allows the following
Banshee/Xenon Bracket 576.501.042
electronic sounders to be mounted with the range
of 1W Xenon Beacons: Banshee IP66 backbox for use with loop powered
• Besson Banshee banshees and FIRECRYERS
• Besson Bedlam 577.001.006
• Loop powered MINERVA Besson Banshee Flush mounting bracket for use with low profile
• MINERVA FIRECRYER voice enhanced banshees - white
sounder
576.501.011
The bracket can be used with any of the 24Vd.c
1W Xenon beacons in red, clear, amber or blue Banshee/Bedlam weatherproof mains adaptor
(Part no.'s 540.001.030/031/032 & 033) pack 240Va.c. to 24Vd.c. use on any 24Vd.c.
Banshee or Bedlam
Banshee Flush Mount Bracket
Besson Wafer Sounder
The standard Besson Wafer sounder is supplied in Technical Specification
white with a blank cover included. The Current: 4mA to 15mA
specification is as follows:
Temperature Range: -40°C to 70°C
Input voltage: 24V d.c. (+/-25%)
Dimensions: Dia 103mm, Height 22mm
Sound Output: 60dBA/90dBA at 1m typical (pot. (excluding coverplate)
Adjustable) offering the same sound formats as
Product Code
the Banshee sounder range. It can therefore be
used in conjunction with the Banshee sounders on 576.501.038
the same site Besson wafer sounder and blank cover in white
Besson Wafer Sounder Flush Mount Bedroom Sounder
Meeting the requirements for BS5839 part 1, the • Can be both Flush and Surface mounted
Bedroom Sounder range is well suited to hotels • Robust terminal connectors to accommodate
and residential environments where aesthetics is a up to 2.5mm2 conductors
prime concern. Matching the sound output of the Product Codes
Banshee range of sounders so therefore can be 576.501.032.A
mixed on a site.
Flush Mount Sounder ADT Branded
Features
576.501.032.T
• Low current consumption 7mA
Flush Mount Sounder Thorn Branded
• Dual sound options selected via a jumper
Flush Mount Sounder switch: ‘Continuous’ and ‘Fast Sweep’ 90dB
Page 76
tyco Fire & Tyco Electronic
Security Product Group
Banshee Slow Whoop
This sounder has the same features as the
standard Banshee sounder but comes with a slow
whoop sound as standard to meet the
requirements of the Dutch Market.
Product Code
576.501.019
24Vd.c. slow whoop low profile red dutch

Banshee IS28
Product Codes
576.501.013
IS28VCL Banshee IS28 BS5839 low frequency
BASEEFA certified intrinsically safe Grey sounder
- 98dBA, 10mA. Certificate number. Ex87B2027
EExia IIC T5 suitable to replace Banshee IS22B
576.501.018
IS28VCH Banshee IS28 high frequency
BASEEFA certified intrinsically safe red sounder -
104dBA, 18mA. Certificate No. Ex87B2027 EExia
IIC T5

Klaxon Secomak Siren


Product Code
576.502.010
MINIMITE Klaxon Secomak 24Vd.c. sounder siren
- range 370 yards

Yodalarms
This versatile range of sounders are ideally Product Codes
suitable for fire, safety and security hazard 576.501.001
warning.
YO3 Yodalarm 3” 24Vd.c. 100dB @ 1Mtr
Technical Specification
576.501.002
Dimensions:
YO5 Yodalarm 5” 24Vd.c. 106dB @ 1Mtr
YO3: 89H x 89W x 85D mm
576.501.003
YO5: 134H x 134W x 128D mm
YO8 Yodalarm 8” 24Vd.c. 112dB @ 1Mtr
YO8: 216H x 216W x 153D mm

Sounder Circuit EOL


The sounder circuit EOL units or EOL resistors Product Code
are supplied with the relevant control panels and 509.013.031
sounder modules. Spare sounder circuit EOL
Spare sounder circuit EOL unit
modules for System 1600, 1700, MINERVA 1-4,
T880 Modules and sounder circuits on the
MINERVA main processor are available as
follows.

Page 77
tyco Fire & Tyco Electronic
Security Product Group
Fulleon Range of Sounders
NOTE: All typical sound output values used are as tested in fully anechoic conditions to prEN54-3. In practical semi-reverberant conditions outputs may be up to
5dB(A) higher dependent on the tone employed.

Roshni
A flexible alarm sounder for Fire and Security Output Voltage: 9-28Vd.c.
applications complete with volume control and dil Typical Current: 24Vd.c.@16mA
switch to provide 32 tones. Typ. Sound Output: @1m 102dB (A)
- Tone 2 similar to Banshee fast sweep Product Codes
- Tone 1 similar to Banshee slow sweep ROSHRDSR
Low profile Roshni with Deep base offers IP65 ROSHNI Sounder deep base - red
protection. All Roshni sounders have synchronised 171.392
start for self synchronisation without third wire. ROSHNI Sounder deep base - white
Technical Specification
Dimensions: 93 Dia x 105D mm
(Deep base)
Colour: Red or white available
Approvals: None (Approved variants
available)

Squashni
The Squashni electronics sounder is the original Product Codes
ceiling sounder for use as a universal fire detector 20-116
platform or as a stand alone sounder complete SQ/H/3 Squashni Hochiki white sounder base set
with blank cover. It comes complete with 28 pre- to tone 3
set tones and volume control and is fully 576.501.030
compatible with Roshni tones, synchronised start. Squashni white 24Vd.c.
Technical Specification 576.501.031
Dimensions: 112 Dia x 27D mm Blank cover plate white for Squashni
Colour: Matched to leading fire
detector manufacturers
Approvals: None (Approved variants
available)
Output Voltage: 9-28Vd.c.
Typical Current: 24Vd.c.@16mA
Typ. Sound Output: @1m 93dB (A)

Askari Compact
The Askari Compact is a compact bedroom Product Codes
sounder for unobtrusive installation. It comes ASKR
complete with 28 pre-set tones and volume control Askari sounder - red
and is fully compatible with Roshni tones, ASKW
synchronised start. Includes matching backbox for Askari sounder - white
surface mounting.
Technical Specification
Dimensions: 87.5H x 85.75W x 36D mm
Colour: Red or white available
Approvals: BS 5839 pt 1
Output Voltage: 9-28Vd.c.
Typical Current: 24Vd.c.@16mA
Typ. Sound Output: @1m 95dB (A)

CF Motorised Bells
The CF Motorised bells are low current, fully Product Codes
suppressed and polarised. 576.501.022.A
Technical Specification 6" Bell 24Vd.c. motorised. 'Fire' text with ADT
Dimensions: 4, 6 & 8” Diameter available Branding
Colour: Red (other colours available 576.501.022.T
to order) 6" Bell 24Vd.c. motorised. 'Fire' text with Thorn
Output Voltage: 18-30Vd.c. Branding
Typical Current: 24Vd.c.@22mA 576.501.023.A
Typ. Sound Output: @1m 94dB (A) 8" Bell 24Vd.c. motorised. 'Fire' text with ADT
Branding
576.501.023.T
8" Bell 24Vd.c. motorised. 'Fire' text with Thorn
576.501.022.A Branding
576.501.023.A

Electronic Solenoid Bell


Unique patented alarm bell with miniature solenoid Product Codes
and integrated electronic control. No backbox 20-100
required for surface wiring. 6” 24Vd.c. Electronic bell, weatherproof - Wormald
Technical Specification branded - white
Dimensions: 6” diameter 20-101
Output Voltage: 18-30Vd.c. 6” 24Vd.c. Electronic bell - Wormald branded - red
Typical Current: 24Vd.c.@30mA
Typ. Sound Output: @1m 94dB (A)

Page 78
tyco Fire & Tyco Electronic
Security Product Group
Flashni
Combined sounder and beacon, combines the Product Code
features of the Roshni electronic sounder with a 20-118
fully integrated Xenon beacon. These sounders Combined Roshni sounder/strobe complete with
are fully compatible with all Roshni tones, deep base
automatic sounder synchronisation. Weather
resistant to IP65.
Technical Specification
Dimensions: 93 Dia x 92D mm
(Shallow base)
93 Dia x 121D mm
(Deep base)
Output Voltage: 18-30Vd.c.
Typical Current: 24Vd.c.@68mA
Typ. Sound Output: @1m 101dB (A)
No. 1st TONE 2nd TONE TYPICAL (mA/24V) TYPICAL SOUND OUTPUT(dB @ 1m)
1 ALT TONES 800/970 at 1/4 Hz 14 18 104
2 SWEEPING 800/970Hz at 7Hz 14 19 105
3 SWEEPING 800/970Hz at 1Hz 14 18 105
4 CONTINUOUS at 2850Hz 14 29 116
5 SWEEPING 2400-2850Hz at 7Hz 4 23 114
6 SWEEPING 2400-2850Hz at 1Hz 4 23 113
7 SLOW WHOOP 14 15 103
8 SWEEP 1200-500 at 1Hz 14 16 103
9 ALT TONES 2400/2850 2Hz 4 27 113
10 INT TONE OF 970Hz at 1Hz 14 1 106
11 ALT TONES 800/970 Hz at 1Hz 14 18 105
12 INT TONE at 2850 Hz at 1Hz 4 20 116
13 970Hz at 1/4 SEC. ON 1 SEC. OFF 14 7 102
14 CONTINUOUS AT 970Hz 14 20 107
15 554 FOR 100ms and 440Hz FOR 400ms 14 12 99
16 INT 660Hz 150ms ON/150ms OFF 16 9 87
17 INT 660Hz 1.8s ON/1.8s OFF 17 12 91
18 INT 660Hz 6.5s ON/13s OFF 18 10 90
19 CONTINUOUS 660Hz 19 14 90
20 ALT 554/440Hz at 1Hz 20 13 95
21 INT 660Hz 1Hz 21 9 87
22 INT 2850Hz 150ms ON 100ms OFF 14 19 113
23 SWEEP 800-970Hz at 50Hz 14 18 105
24 SWEEP 2400-2850Hz at 50Hz 4 22 112

Page 79
tyco Fire & Tyco Electronic
Security Product Group
MINERVA Firecryer - Voice Enhanced Sounders
Firecryer
Synchronised and Unsynchronised Variants Standard Messages
Unsynchronised versions provide fast retrofit and AK - “Fire Emergency, Please remain calm and
are acceptable if only one FIRECRYER is used evacuate the building immediately”
per area to enhance the electronic sounders. AB - “This is a fire alert. This is a fire alert. Await
Synchronised variants only require a synchro further instructions. Await further instructions.”
board adding at the fire panel and then allow all
SP - “This is an ADT fire alarm test. No action
FIRECRYERs on two sounder circuits to be
required”
synchronised.
AC - “This is a fire alarm test. No action required.
Low Power
No action required.”
The FIRECRYER takes marginally more power
AD - “All clear. All clear. No further action
than an equivalent electronic sounder. This
required.”
enables voice enhanced sounders to be offered
without the high additional cost of large battery
backups. Sync Board MFC 1SB MFC4SB
The MINERVA FIRECRYER is an electronic Standard Products PCB Dimensions 75.5 x 100mm 138 x 100mm
sounder, which provides as default the same The FIRECRYER is available in 3 models
electronic sound as the MINERVA Besson EMC/RFI CE Marked
(unsynchronised, synchronised and 4 message
Banshees. In addition, the FIRECRYER provides synchronised) in Thorn and ADT branding with Operating Temp -5 to +55°C
up to 4 predefined voice messages, which can be predefined English messages and 100dBA fast Operating Voltage NA 18-30V d.c.
synchronised across a zone of sounders. The sweep alert sound to comply with BS5839Pt1.
FIRECRYER offers an excellent service upgrade Quiescent Current NA 6mA (Max)
Other variants with different branding, different
opportunity in the UK for systems installed to language messages and different tones are Message Mode 28mA
BS5839pt1 and many also provide opportunities available upon request.
elsewhere. Sounder Circuit 2 x 500mA Fused
Technical Specification
Key Features
Dimensions : IP45 - 92dia 61.3 Hmm Product Codes
Single and Four Message Variants
IP66 - 92dia 85.5 Hmm 576.501.037
A single message can confirm that the electronic
Operating Voltage: Nominally 24Vd.c. MFC4DEMO Firecryer 4 message demo box
sound is a fire alarm warning and differentiate it
from other electronic sounders used in an Min. 18Vd.c. Max. 30Vd.c. 576.501.100
environment. With four messages fire tests can be Current Consumption:Average 19mA MFC1SB Firecryer single message synch board
easily differentiated from alert and evacuate Min. 10mA for use with single message synchronised
messages. MINERVA Firecryers
Max.23mA
Two Wire Connection 576.501.101
(Subject to message)
The FIRECRYER uses a standard 2 wire 24V d.c. MFC4SB Firecryer 4 message synch board for
(at max. output)
connection to carry power, message switching and use with 4 message MINERVA Firecryers
message synchronisation. This enables a quick Sound output: Fast sweep - 100dBA
576.501.102
and easy upgrade to existing bells and sounders Voice message: 97dBA approx
MFC1ENC 1 message synch board enclosure for
MINERVA Banshee Compatible Volume Control Via variable resistor with 20dB use with 576.501.100
The electronic alarm sound and mechanics of the range from maximum
576.501.103
FIRECRYER are the same as other Banshee Polarity D.C. reverse polarity protection
MFC4ENC 4 message synch board enclosure
sounders in the range. This allows them to be Operating Temp: -5°C to +55°C with 3 position keyswitch for use with 576.501.101
mixed with other sounders in a zone. It also
Humidity: 90% relative humidity (non- 576.501.042
means that existing Banshees can be very quickly
condensing)
upgraded to FIRECRYERs. An ideal service sale. Banshee IP66 backbox for Loop powered
Weatherproofing: Standard base - IP45 Banshee and Firecryers
Special base - IP66
Housing Material: Red Flame-retardant ABS
Product Codes Product Message Brand Synchronised
Reference 1 2 3 4
576.501.034.A MFC1SEA AK - - - ADT Yes
576.501.034.T MFC1SET AK - - - Thorn Yes
576.501.035.A MFC4SUA AK AB SP AE ADT Yes
576.501.035.T MFC4SET AK AB AC AE Thorn Yes
576.501.036.A MFC1EA AK - - - ADT No
576.501.036.T MFC1ET AK - - - Thorn No
576.501.104.A *MFC4SCA Customer Defined ADT Yes
576.501.104.T *MFC4SCT Customer Defined Thorn Yes
* For recording of special messages there is a charge. This can be ordered under product code
576.501.105 MFC-CM. This includes the supply of a different timer chip for MFC4SB synchronisation
board.

Page 80
tyco Fire & Tyco Electronic
Security Product Group
Visual Indicators
Single Gang Lamp/Buzzer Units
Lamp Buzzer unit used for local alarms when high 540.001.013
level audible warnings may not be appropriate MK2LMP/S Lamp (red)/buzzer unit surface
available in flush and surface mount versions to fit mounting MK2. Labelled ‘Fire’
standard single backboxes
Dimensions: 90H x 90W x 40D mm
Product Codes
540.001.012
Lamp (red)/buzzer unit flush mounting MK2
including single gang backbox. Labelled ‘Fire’

Xenon Beacons - 24V Including Surface Mount Adaptor


The mounting base is available to mount both 540.001.031
beacon and sounder. Low profile blue 24Vd.c. 1 watt
Features 540.001.032
• Available in 12 and 24 Volts Low profile amber 24Vd.c. 1 watt
• Available in 1, 2, 3 and 5 watts
540.001.033
• Protected to I.P. 65
• Attractive low profile design Low profile red 24Vd.c. 1 watt
• Optional bracket for mounting both Beacon and 20-112
Banshee Low profile 2 watt Red
These high quality range of the Xenon beacons
Product Codes 20-113
are tested to IP 65 making them ideal for the most
stringent applications. 540.001.030 Low profile 5 watt Red
Each beacon incorporates a low profile Frestral Low profile clear 24Vd.c. 1 watt 20-120
lens designed to give maximum light output. Low profile 3 watt Red
Technical Specification

Voltage Power Output Alarm Current Flash Rate Rating Temp. Range Dimensions (mm)
V d.c. Watt(s) mA Height Diameter
24 1 42 60/min IP65 -30 to +70°C 51 75
24 2 84 60/min IP65 -30 to +70°C 51 75
24 3 126 60/min IP65 -30 to +70°C 51 75
24 5 210 60/min IP65 -30 to +70°C 75 90

Voice Alarm Modules


VM520 Voice Module
Features Technical Specification
. Fully monitored system when used in Operating temperature: -20oC to +70oC
conjunction with MINERVA Analogue Relative Humidity: up to 95% non-
condensing
Addressable Fire Controller, with all speaker
Addressable circuit input:125m A from loop
cabling faults detected, enabling use of this
unit on projects with full BS5839 requirements Direct Message trigger: Volt free closing
contacts (1 per
• Customised messages available• message)
Messages can be triggered via MINERVA Power Supply 20 to 32 Vd.c.
address loop or via closing contact inputs Quiescent Current 15 mA
• Output capacity for up to four loudspeakers Alarm Current 120mA per speaker
• Clear “test” message can be transmitted for Product Codes
the weekly system check, instead of 577.001.101
The VM520 is a simple voice evacuation module
“evacuate”. This will prevent any VM520 Housing
which memorises and amplifies three voice
messages programmed during manufacturing. misunderstandings at test time. 577.001.102
The VM520 is designed to provide voice VM520 PCB (requires housing)
evacuation in small buildings or small public areas Manual - Vol08A-02-D14 “Ancillaries Manual” 577.001.107
in large buildings. VM520 PEPROM (IC6)

Flush Mounting Loudspeaker


Both of these loudspeakers are tested for
compatibility with the VM520.
Product Codes
577.001.106
Flush mounting loudspeaker 8 ohms
577.001.109
Metal cabinet speaker

Manual - Vol08A-02-D14 “Ancillaries Manual”

Page 81
tyco Fire & Tyco Electronic
Security Product Group
Auxiliary Interface Relays
Boxed Relays

567.001.004 567.005.004 567.007.008


Relay 5000 One or two plug in relays on PCB. Relay 5010. Supplied with 1 PCB but can fit a Alarm Relay 240Va.c. MK4
Order relay (569.001.007) separately. maximum of 2 PCB’s each containing up to 5 plug 567.007.009
in relays. Order relay (569.001.007) separately.
567.005.005 Alarm Relay 24Vd.c. MK4
568.001.006
Relay 5016. Supplied with 1 PCB but can fit a
Relay 5016 PCB (8 Relays)
maximum of 2 PCB’s each containing up to 8 DIL
relays.

Spare Relay Housings

568.001.007 568.001.008
Relay 5000 Housing auxiliary relay (small) Relay 5010 Housing auxiliary relay (large)

Cradle Relay and Retaining Clip


Product Code
569.001.007
Cradle relay and retaining clip 2 C/O 26V nominal
700K ohm coil 5 amp used with Relay 5000 and
5010

Miscellaneous Fire Products and Spares


Sprinkler Delay Module Zonal Sounder Circuit Monitoring PCB
Product Code The Zonal Sounder Circuit Monitoring PCB provides relay inputs (5 off) to
584.002.001 interface to 5 separate, and monitored sounder circuits. Each has a
maximum of 2 Amps.
Sprinkler delay module. Provides
preset delay between sprinkler Product Code
pressure switch and conventional 541.001.018
fire detection panel. Zonal sounder circuit monitoring PCB

Fire Notice Frames


These frames are used mainly for Fire Alarm Product Codes
Zone Charts and are available to fit A4 to A1 size 525.001.005
drawings. These come supplied with fitting hooks.
A4 Dimensions: 212mm x 297mm
525.001.006
A3 Dimensions: 280mm x 356mm
525.001.007
A1 Dimensions: 483mm x 783mm
525.001.008
A2 Dimensions: 483mm x 367mm

Page 82
tyco Fire & Tyco Electronic
Security Product Group
Fire Resistant Cable
DÄTWYLER Lifeline cable is suitable for fire tinned drain wire and requires no special The following DÄTWYLER Lifeline cables are held
alarms and emergency lighting where BS6387 terminations, tools or ferrules for installation. in stock at Tyco Electronic Product Group
and BS7629 standards are acceptable and meets Full details of Lifeline cable can be found in the Letchworth, together with suitable P clips and
the installation and performance requirements of: DÄTWYLER Lifeline datasheets on the Tyco glands. Cables are priced per metre but must be
• BS5839 Pt.1 for use in fire alarms Electronic Product Group website ordered in units of 100 metre. P clips and glands
• BS5266 for use with emergency lighting (www.tycofire.com). are priced each but must be ordered in packs.
• BS4066 ‘Tests on electrical cable under fire DÄTWYLER offer a wide range of cable and
conditions’ safety cabling systems including complete safety
• IEC331 fire resistance cable systems to DIN4102 part 12. All
Lifeline is LPCB approved to BS6387 CAT CWZ DÄTWYLER products are available at preferential
and BASEC approved to BS7629. prices to Tyco companies via Tyco Electronic
Lifeline is low smoke, zero halogen, has an Product Group. For more information contact Rob
integral aluminium backed mylar tape screen with Sutcliffe (rsutcliffe@tycoint.com).

Product Codes Description - DÄTWYLER Lifeline cable Technical Specification


No. Cores Core Size Colour Clips Construction
599.048.020 2 + earth 1 mm Red P34 R Conductor: Bare copper, solid or
599.048.021 2 + earth 1 mm White P34 W stranded to BS 6360
599.048.022 2 + earth 1.5 mm Red P34 R Insulation: Special double layer
599.048.023 2 + earth 1.5 mm White P34 W insulation according to
599.048.024 2 + earth 2.5 mm Red P37 R BS 7655, E15
599.048.025 2 + earth 2.5 mm White P37 W Inner Covering: High temperature resistant
glassfibre tape
599.048.026 3 + earth 1 mm Red P34 R
Screening: Al-Laminated tape with
599.048.027 3 + earth 1 mm White P34 W
tinned copper drain wire,
599.048.028 3 + earth 1.5 mm Red P37 R solid to BS 6360
599.048.029 3 + earth 1.5 mm White P37 W
Outer Sheath: Flame retardant polyolefin
599.048.030 3 + earth 2.5 mm Red P40 R compound according to
599.048.031 3 + earth 2.5 mm White P40 W BS 7655, LTS3
599.048.032 4 + earth 1 mm Red P37 R Technical Properties
599.048.033 4 + earth 1 mm White P37 W Rated Voltage: 300/500V
599.048.034 4 + earth 1.5 mm Red P40 R
Test Voltage: 2000V, 50Hz core/core
599.048.035 4 + earth 1.5 mm White P40 W
2000V, 50Hz core/screen
599.048.036 4 + earth 2.5 mm Red P43 R
Operating Temp.: -15oC to +90oC
599.048.037 4 + earth 2.5 mm White P43 W
Core Colours:
599.048.038 7 + earth 1.5 mm Red P43 R
. 2 cores + earth: red, black
599.048.039 7 + earth 1.5 mm White P43 W
. 3 cores + earth: red, yellow, blue
Product Codes Description - DÄTWYLER Lifeline Fire Resistant P Clips & Glands . 4 cores + earth: red, yellow,blue,black
Qty. per pack Reference Colour . From 7 cores + earth: black with white
599.048.001 50 P34 Red number printing
599.048.002 50 P34 White Sheath Colour: Red or white
599.048.003 50 P37 Red General Properties
599.048.004 50 P37 White . Zero Halogen, no corrosive gases - IEC
599.048.005 50 P40 Red 60754-2, BS 6425 part 1
599.048.006 50 P40 White . Reduced fire propagation - IEC 60332-3, BS
4066 part 3
599.048.007 50 P43 Red
. Minimum smoke emission - IEC 61034, BS
599.048.008 50 P43 White 7622
599.048.009 10 NG1 Red . Insulation integrity - IEC 60331 (FE180), BS
599.048.010 10 NG1 White 6387 (cat. CWZ)
599.048.011 10 NG2 Red Approvals
599.048.012 10 NG2 White . BASEC

No. of Cores x Cross Section (n x mm2) Copper Content (Kg/Km) Total Weight (Kg/Km) Outer Diameter (approx. mm) Calorific Potential (KWh/m)
2 x 1.0 19 75 7.4 0.16
2 x 1.5 29 97 8.2 0.18
2 x 2.5 48 141 9.6 0.24
3 x 1.0 29 92 7.8 0.18
3 x 1.5 43 120 8.6 0.22
3 x 2.5 72 180 10.2 0.30
4 x 1.0 39 114 8.6 0.23
4 x 1.5 58 149 9.6 0.27
4 x 2.5 96 223 11.3 0.37
7 x 1.5 101 230 11.5 0.41

Page 83
tyco Fire & Tyco Electronic
Security Product Group
Water Leak Detection Alarms
Introduction custom made with a variety of types of detection . Electrical Plant and Tank Areas
The Water Leak detection system is a water sensor to suit the characteristics of the areas to be . Valuables, Antiques and Artifacts
detection alarm designed to be used in situations covered. . In general, wherever the presence of water
where not just flooding but also undue dampness This system has been designed for ease of could be a potential problem to people,
could cause damage or ultimately become installation and modern micro-electronics ensure a equipment, perishable stock, data/information
dangerous. high degree of reliability. archives and record stores, hospital theatres
The system comprises an electronic monitoring Typical Applications and so on. There are also sensors for the
and alarm control panel connected to sensors . Computer Rooms, Telecommunications and detection of non-conductive fluids such as
located in the area requiring protection and can be Office Areas diesel/oil.

DETEK Water Flood Detection Controllers


All systems have a test facility to enable simple Technical Specification
regular confidence checking of the equipment. Dimensions: 160H x 220W x 62D mm
Lockable cabinets constructed in mild steel with (Single Zone)
stove enamelled finish for surface mounting. 270H x 362W x 84D mm
20mm Knockouts are provided for ease of cable (Multi Zone)
entry. Supply: Single phase 240Va.c., 25VA
Indications of status on each zone, wiring fault and Max.
supply healthy. Mains fail battery back-up Relay Contacts: Two sets of volt free change
indication where applicable. over contacts for alarm and
The 85dBA pulsed audible alarm has a fully one set for wiring fault or
functional local mute facility. power loss. These may be
Quality used to link into Building
. Electro Magnetic Compatibility - All of the Management Systems or for
control panels and sensors have been perfor- remote alarms and beacons
mance tested to meet the requirements of up to 2A, 50Va.c./d.c.
EN55022 for emissions and EN50092 for Product Codes
immunity 508.200.004
Controller electronics are housed in a robust . British International Standards - The equip- 1 Zone - water/flood control panel
cabinet and provide accurate sensing for water ment is manufactured in accordance with EN 508.200.005
leakage and comprehensive alarm facilities. ISO 9001 procedures 2 Zone - water/flood control panel
The system is ideal for all types of applications . Electrical Safety - Manufactured in accor- 508.200.006
utilising a mixture of sensors on a single control dance with Electrical Equipment (Safety) 4 Zone - water/flood control panel
panel to give optimum flexibility. Regulations 1994 - Low Voltage Directive (SI
1994/3260).

Compatible Sensors
Sensor Cable, Sensor Pads & Probe Sensors
Product Codes
Sensor Cable
Sensor Pads 516.200.010
CD/5 5 metre length of sensing cable
516.200.011
CD/10 10 metre length of sensing cable
516.200.012
SOL Start of line for sensing cable
516.200.013
EOL End of line for sensing cable
516.200.014
Sensor Cable FF1 Sensing cable fixing clips
516.200.015
CDT Sensing cable identification tags
Sensor Pads
516.200.016
Probe Sensor SFU Sensor pad face up
Sensor Cable Sensor Pads 516.200.006
Sensor cable comprises high flexibility conductors Sensor pads are constructed from glass fibre with SFD Sensor pad face down
insulated by Helagaine mono-filament braiding. an anti-corrosive nickel plated surface. Pads will 516.200.007
Cable or tape sensors are suitable for general detect a few cc’s of liquid and are either face up SFD/C Cover for sensor pad face down
protection under false floors, or can be fastened for location under vulnerable points or face down Probe Sensors
directly to pipework enabling coverage in ceiling for a general coverage. 516.200.004
void areas. Technical Specification SPS/V Vetical mounting probe sensor complete
The cables can be connected together, up to Dimensions: 115H x 160W mm with cover
100m, to cater for larger areas. Probe Sensors 516.200.005
For each zone a ‘start of line’ and an ‘end of line’ Probe sensors are the least sensitive and are Spare Protective cover for probe detector
module is required. often employed as water level sensors. In general
Technical Specification use the sensor is enclosed in a protective cover
Dimensions: 8mm dia which also provides a means for fixing and 20mm
gland entry. The probe is designed for vertical
mounting at skirting level though may be mounted
in voids or sumps. A screw allows 16mm height
adjustment after the sensor is installed.
Technical Specification
Dimensions: 85H x 62W x 62D mm

Page 84
tyco Fire & Tyco Electronic
Security Product Group
Wire Free Fire Product Range
Introduction The Radio Survey Typical Applications
Wire free fire system technology is fast becoming It is important that a radio survey is carried out by . Heritage and Listed Buildings
a recognised and accepted alternative to wired fire trained personnel on all sites, before a complete . Art Galleries and Museums
alarm systems. The Tyco Electronic Product system quotation can be made. Please contact . Schools and Colleges
Group Radio Fire Alarm System provides a level of Tyco Radio Systems at Walthamstow for . Hospitals, Clinics and Nursing Homes
performance and reliability comparable to hard- assistance. . Temporary Systems for Refurbishments
wired systems. It also has the added advantage of . Airports and Military Bases
Features
being totally flexible, quick and easy to install, with . Government and Council Buildings
. Detectors fire tested to prEN 54 Part 7
virtually no damage or disruption. . Exhibition Complexes and Stadia
. Designed to meet BS5839 Part 4
This enables the installation of a fire alarm system
. Unique Carbon Monoxide fire detector
to be carried out in an occupied building where NOTE: The system elements and associated
. Minimum installation damage and disruption
cabling is unacceptable, unwelcome, disruptive or product codes described in the Wire Free section,
. Flexible system design up to 100 zones
impracticable. The cost of “making good” and relate to the UK frequency variants as approved by
. System easily modified or extended
redecorating is significantly reduced with wired the Home Office for use in “low powered” systems
. 80 Character LCD pinpoints each alarm with
systems. in the UK. 173.225 MHz (field devices) and 458
plain text location messages
Radio Systems are highly cost effective and can MHz (battery powered sounders). These
. Full zonal LED display and detailed fault
easily be modified or extended to combine with frequencies may be suitable for applications in
annunciation
existing hard wired systems. A system can be other countries. Please contact Tyco Electronic
. Suitable for permanent or temporary
tailored for use in any existing building to meet Product Group for further information.
applications
highly individual needs for many commercial and
. 200 Event memory
industrial applications. Regarding fire detection,
. Up to 31 repeater panels
the radio system can be considered to be identical
. Long battery life
to a hard-wired system, with the fire survey carried
out to the same standards.
The Radio System

Main Control

KEY

TX Unit

Power AC Supply

Detector

Callpoint

Sounder

Radio Sounder

Repeater Unit

Controllers
LCD. Controls on the unit include Silence, Sound Technical Specification
(Evacuate), Reset, Mute and Test, all of which are Dimensions: 400H x 500W x 185D mm
enabled/disabled through the use of the controller Power Requirements:220/240V, 50Hz
keyswitch. Outputs: 3 x 12Vd.c. monitored relay
The controller monitors the status of the system at outputs up to 1A load
all times. Internal functions on the controller, such 1 x Volt free contact
as battery charge, aerial, and various radio 1 x Clean changeover
functions are monitored and also faults on Product Codes
detectors, the battery condition and tamper are 508.019.001
monitored. TRS Control panel 100 zone
A 100 individual Zone, LED matrix is provided, 508.019.002
together with a separate display to indicate zone TRS Control panel 100 zone plus printer
and device number. Transmit and receive LED’s 509.019.021
The main controller for the Radio Fire Detection also indicate activity on the radio communication TRS Aerial 1m LD20 with bracket
System has been designed to meet BS 5839 link. 3072
Part 4 - 1988. Each unit can support up to 200 There are monitored relay outputs available on the 12V 7Ah Rechargeable battery
direct devices, plus up to 31 repeater panels each controller which can be programmed to operate
with 200 devices. from any zone.
The controller’s 80 character LCD is used to The controller can also support up to 64 battery
display system events in ‘Plain English’ giving powered Radio Sounders (BPS) by fitting an
relevant zone, device and floor numbers for each optional BPS controller card. There is also a
event. Two hundred events are stored in the printer port to allow a printer unit to be
controllers event log which can be viewed from the incorporated into the controller.

Page 85
tyco Fire & Tyco Electronic
Security Product Group
Field Devices
Radio transmitters are incorporated into each field device to communicate with controllers. The units are programmed with a device number, zone number,
system code and RX number and TX number. These identities are sent back to the controller in the event of a fire, battery low condition or tamper, to precisely
identify the location of the event on the controller display.
Power to the radio transmitter is supplied by a two stage Lithium battery pack. The battery pack provides up to five years service under normal operating
conditions. When primary power begins to deteriorate, a signal is sent to the controller and a low battery is indicated. After a ‘battery low’ signal has been
reported, devices will continue to operate for a further three months.

Optical Smoke Detectors


These detectors are capable of detecting the thrips. Smoke entering the sampling chamber
visible smoke produced by materials which scatters the infra-red light pulses onto a photo-
smoulder or burn slowly, ie soft furnishings, plastic diode. These pulses are converted to an electrical
foam etc or ‘smoke’ produced by an overheated signal which is compared against a preset alarm
but unburned PVC. level and signalled to the controller.
Optical detectors are particularly suitable for Technical Specification
general applications and areas where cable Dimensions: 110 dia x 76mm
overheating may occur, eg. electrical services Product Codes
areas. 516.131.010
The novel design of the asymmetric sampling TRS Lo pro optical smoke detector
chamber and signal processing techniques stop 517.130.001
unwanted alarms caused by very small insects, ie. Radio fire alarm detector base plate

Heat Detectors
The rate of rise/fixed temperature heat detectors Product Codes
can be used in areas where smoke sensors are 516.133.010
unsuitable due to environmental conditions, TRS Lo pro fixed temperature heat detector
(smoke, dust etc.). Such areas include kitchens, 516.134.010
locker rooms, canteens, garages, loading bays TRS Lo pro rate of rise heat detector
etc. 517.130.001
These detectors use two networked thermistors in Radio fire alarm detector base plate
a bridge configuration to provide a fast response
that depends on both absolute temperatures and
notes the change of temperature.
Technical Specification
Dimensions: 110 dia x 76mm

CO Fire Detectors
The CO fire detector is a unique general purpose Technical Specification
fire detector which provides very early warning of Dimensions: 110 dia x 76mm
slow smouldering fires. Ideal for sleeping risks the Product Codes
CO fire detector is also well suited to many 516.132.010
applications where heat detection is insufficient TRS Lo pro CO detector
but smoke detection causes false alarms. 517.130.001
As CO travels more freely than smoke the Radio fire alarm detector base plate
positions of CO fire detectors is more flexible.
This feature is particularly useful in large complex
structures such as atria and warehouses, where
positioning of smoke detectors is difficult. The
MU601 is LPCB Approved.

Ion Chamber Smoke Detectors


These Ion Chamber detectors react to the visible Technical Specification
and invisible fire aerosols (products of combustion) Dimensions: 110 dia x 76mm
and are therefore capable of detecting the early Product Codes
presence of hot smouldering and flaming fires 516.130.010
such as wood, paper etc. They are suitable for TRS Lo Pro Ion Chamber Smoke Detector
general applications in all areas. 517.130.001
These detectors use a dual ionisation chamber Radio fire alarm detector base plate
technique in which the air is ionised by a
radioactive source. The presence of smoke in the
sampling chamber causes a change in the balance
voltage between the two chambers.

Callpoints
The Radio Callpoint is designed to enable an Product Code
alarm signal to be generated manually from a 514.006.012
normal break glass callpoint. The alarm signal is TRS Callpoint - 173.225MHz
sent immediately to the controller. An LED on the
callpoint indicates that the device has been
operated.
Technical Specification
Dimensions: 97H x 160W x 70D mm

Page 86
tyco Fire & Tyco Electronic
Security Product Group
Transmitter Units
A universal transmitter is also available to allow
connection to existing fire systems or other inputs,
to transmit fire or fault signals back to the
controller.
Technical Specification
Dimensions: 160H x 70W mm
Product Codes
509.019.051
TRS Transmitter unit
509.019.153
TRS Transmitter unit with external aerial connector

Sounders
Controllers can support both Hard Wired Sounders and Battery Powered Sounders (when BPS controller
card is fitted). Radio Sounders (BPS units) can be specified where wiring is not possible or desirable.
The BPS unit provides sounder activation without the need for an external power source or wiring and
uses a Besson Banshee sounder. The Hard Wired Sounder normally specified is a 12Vd.c. Roshni type.

Product Code
ROSHRDSR
ROSHNI Hard Wired Sounder deep base - red

ROSHRDSR

Radio Sounders

509.019.132 509.019.131 509.019.038


Battery Powered Sounders and Hard Wired Sounders can be mixed on a system. The Battery Powered Technical Specification - BPS Unit
Sounder internal power source is a Lithium Battery pack designed to provide up to three years service Dimensions: 104 dia x 85mm
under normal operating conditions. Sound Output: 103dB +/- 3dB
Monitoring is achieved by two-way communication between the radio sounder unit and its’ respective Frequency: 700/950Hz
controller or repeater panel. Fault, tamper and transmit status are indicated on the unit itself; tamper and Product Codes
low battery are displayed at the control panel. 509.019.132
TRS Radio sounder unit battery powered
Each radio sounder unit is capable of driving one extra sounder which must be wired from an adjacent 509.019.131
location, such as the other side of a hotel room wall. Up to 64 radio sounders can be configured to one TRS Radio sounder controller card
control or repeater panel and a maximum of 256 sounders per system can be specified. The sounder 509.019.038
utilised in the BPS unit is the standard 24Vd.c. Besson Banshee. TRS BPS Radio sounder dipole aerial double whip

Aerials & Anciliaries


Aerials
Product Codes
509.019.021
TRS Aerial 1m LD20 with bracket
509.019.022
TRS Aerial 3m LD18 173MHz
509.019.023
TRS Aerial 1m LD20N with bracket
509.019.024
TRS Aerial 3m LD18N & CCN2 plug crimped
509.019.028
TRS Bracket wall mounted 3m aerials
509.019.029
TRS Bracket pole mounted 3m aerials
509.019.038
509.019.021 TRS BPS Radio sounder dipole aerial double whip
The standard gain aerial for detectors and field
device communications to the controllers is the
LD20 range.

The 3 metre aerial is a high gain unit and may be


used in specialist applications. 509.019.022

Page 87
tyco Fire & Tyco Electronic
Security Product Group
20 Relay Expander Cards
Relay expander cards may be specified to extend
the relay capacity from the main controller.
Normally only one card can be fitted to the
controller and may be used for connection to
sounders or other devices.

Product Codes
509.019.061
TRS 20 Relay normally open expander card
509.019.077
TRS 20 Relay normally closed expander card

8 Way Input Expander Card


The 8 Way input expander card can be used to
directly wire up to 8 hard wired signal pairs,
carrying alarm information from external sources.

Product Code
509.019.059
TRS 8 Way input expander card

EPROMS & Software


Message EPROMs
Message EPROM Copy Message EPROM NOTE: To purchase these products please contact
The Message EPROM may be used to enable the Copy Message EPROMs may be used in repeater Tyco Radio Systems, Walthamstow.
controller to display plain English text messages panels where English text information is required Tel: 0208 919 6273.
relating to alarm and fault information received to be displayed.
from field devices and repeater panels. The If a Message EPROM is not used in the controller,
Message EPROM is also used to store the system zone and detector information only will be
configuration (ie cause and effect). displayed and the cause and effect will be simple
“one out all out”.

Field & Programming Tools


NOTE: Software is available to enable Product Code
programming of field devices and also available for 517.130.008
configuration and programming of EPROMs. TRS Detector removal tool
Please contact Tyco Radio Systems, Walthamstow
for further details.
Tel: 0208 919 6273.

Wirefree Spares
Product Codes
509.019.080
TRS TX/RX PCB & Decoder PCB matched pair
3072
12V 7Ah Rechargeable battery
560.002.031
Battery pack Lithium System 3000

509.019.080 560.002.031

Page 88
APPROVALS LISTING OF COMPANY EQUIPMENT
Thorn Security Limited is registered by British Standards Institution to KRS Korean Register of Shipping.
BS5750 : Part 1 LPCB Loss Prevention Certification Board.
Note: That while every effort is made to keep this document updated, some LRS Lloyds Register of Shipping.
approvals will be renewed and new approvals will be acquired between
MIE Spanish Ministry of Industry and Energy
updates. Any queries, reference approvals, should be made to the Approvals
Engineer [TYCO ELECTRONIC PRODUCT GROUP} Sunbury-on-Thames. MOI Italian Ministry of the Interior.
The approvals obtained for company equipment are listed in Table 1. The MSA Marine Certification Association
approval bodies are identified by the following NACOSS National Approval Council for Security Systems.
abbreviations:- NC Not Coded.
AMSA Australian Maritime Safety Authority. NKK Japanese Register of Shipping.[Nippon Kaiji Kyokai].
ABS American Bureau of Shipping. NMA(S) National Maritime Administration [Sweden, Sjöfartsverket].
BT British Telecom. NMD Norwegian Maritime Directorate [Sjøfartdirektortet].
BASEEFA British Approval Service for Electrical Equipment in Flammable NSI Nederlands Shipping Inspectorate.
Atmospheres. NPTT Dutch Post Office.
BR Brunamalastofnun Rikisins [Iceland Govt. Approval]. NRC Nuclear Regulatory Commission [USA].
BSI British Standards Institute. NRPB National Radiological Protection Board [UK].
BV Bureau Veritas [France]. NSTC China - National Supervisory Test Centre China.
CCG Canadian Coastguard. PRS Polish Register of Shipping.
CCR China Corporation Register of Shipping. PSB Productivity Standards Board of Singapore’s Product Listing
CCS (ZC) China Classification Society. Scheme (PLS)
CIRL Construction Industry Research Laboratory [Australia]. PTB Physikalisch Technisches Bundesanstalt [Germany].
CSA Canadian Standards Association. RA Radiocommunications Authority [DTI]
DDRK DDR Schiffsrevision und Klassifikation [Germany]. RINA Registro Italiano Navale [Italy].
DMA Danish Maritime Authority [Søfartsstyrelsen]. RNR Rumanian Register of Shipping.
DOT Department of Transport [UK] - not used. Now Marine RRS Maritime Register of Shipping [Russia].
Certification Association [MSA]. SAA Standards Association of Australia.
DNV Det Norske Veritas. SSL Scientific Services Laboratory of Australia
DTI Department of Trade and Industry. UL Underwriters’ Laboratories of the United States.
FM Factory Mutual [USA]. ULC Underwriters’ Laboratories of Canada
GL Germanischer Lloyd. USCG United States Coastguard.
HRS Hellenic Register of Shipping VdS Verband der Sachversicherer e.V. [Association of Property
IPTT An Roinn agus Telegrafa [Irish Posts, Telephones and Insurers] (Germany).
Telegraphs].
IR India Radiology. Note: Items in Table 1 with a ‘*’ against the date, indicates that approvals
KM & PA Korean Marine and Port Authority. have been applied for but not yet been received.
TABLE 1: APPROVALS LISTING OF COMPANY EQUIPMENT
Type Description Authority Type Description Authority
601 Intrinsically Safe System [Ex ia] ABS, BASEEFA [82254] H602, H900, Heat Detector ABS, AMSA (H602 & H902), BV
CCS (ZC), PRS, RINA, RNR H901,H902 CCR - (H902 only), CCS (ZC)
NKK DMA - (H602 only)*, DNV, MSA
602 Analogue Addressable BASEEFA [89Y2204], NKK GL - (not H900), KRS, LPCB
Intrinsically Safe System [Ex ia] PRS, RNR LRS, NKK
1700 1-3 Zone Fire LPCB Approved to BS3116 NSTC - (H602/902 only), RRS
Detection System NSTC H604 Heat Detector ABS, BV, CCS (ZC), DNV, GL
1700 4-64 Zone Fire LPCB Approved to BS3116 KRS, LRS, NKK
Detection System NSTC H904 ABS, GL, KRS, LRS, NKK
1700 TNO 4-64 Zone Fire TNO(Netherlands) IF500Ex BASEEFA, BV
Detection System LI520 ABS, BV, CCS (ZC), DMA*
1/2/4 Zone Fire Detection Systems LPCB DNV, MSA, GL*, KRS, LPCB
C2440 Charger BT, RINA LRS, NKK, NMA(S), PRS
CM 520 CCS (ZC), ABS, BV, CCS (ZC) RNR, RRS, USCG
DMA*, DNV, MSA, GL*, KRS LI530Ex BASEEFA
LPCB, LRS, NKK, NMA(S) M300 Detector Base DNV, LRS, KRS, RNR
PRS, RNR, RRS, USCG M300Ex Detector Base [I.S.] BASEEFA, KRS, LRS, RNR
CP 200 Call Point GL, LRS, NKK, RNR, RRS MD301 Gr.1 Rate of Rise ABS, BSI, BV, CCS (ZC), DMA
AMSA, CCS (ZC) Heat Detector DNV, MSA, GL, KRS, LPCB
CP 210, 220, 230, LRS, NKK - (not 270) LRS, NKK, PRS, RNR, RRS
240, 260, 270 AMSA - (230 only) MD301Ex Gr.1 Rate of Rise [I.S.] ABS, BASEEFA, BV, CCS (ZC)
GL - (230 only) Heat Detector DMA, DNV, GL, KRS, LRS
CCS (ZC) - (230 only), RNR NKK, PRS, RNR, RRS
CP 250 LRS, NKK, RRS MD303Ex Gr.3 Rate of Rise [I.S.] BASEEFA, BV
CP 520 ABS, DMA*, MSA, GL*, KRS Heat Detector
LRS, NKK, NMA(S), RNR MD305Ex Temp. Range 2 [I.S.] BASEEFA, BV
RRS, USCG Heat Detector
CP 530 ABS, DMA*, DNV, MSA MF301 Ion Chamber ABS, AMSA, BSI, BV, CCS (ZC)
GL*, KRS, LRS, NKK DMA, DNV, MSA, GL, KRS
NMA(S), RNR, RRS, USCG LPCB, LRS, NKK, NRPB
CP 540Ex BV, DNV, NKK NSTC, PRS, IR, RNR, RRS
CP920 LPCB MF30Ex Ion Chamber [I.S.] ABS, BASEEFA, BV, CCS (ZC)
CP930 LPCB DMA, DNV, GL, KRS, LRS, NKK
DHM35/69 DNV NRPB, PRS, RNR, RRS
DM 520 ABS, BV, CCS (ZC), DMA* MF SERIES (300, 400, 500) NRC
DNV, MSA, GL*, KRS, LPCB MR301 Photo-Optical ABS, AMSA, BSI, BV, CCS (ZC)
LRS, NKK, NMA(S), PRS, RNR Smoke Detector DMA, DNV, MSA, GL, KRS
RRS, USCG LPCB, LRS, MOI, NKK, PRS
H600, H601 Heat Detector ABS, BV, CCS (ZC) RNR, RRS
DMA - (not H600)**, DNV MR301Ex Photo-Optical ABS, BASEEFA, BV, CCS (ZC)
MSA, GL - (not H600), KRS Smoke Detector [I.S.] DMA, DNV, GL, KRS, LRS, NKK
LPCB, LRS, NKK, RRS PRS, RNR, RRS
MR301T High Performance Optical LPCB
Smoke Detector [I.S.]

Page 89
APPROVALS LISTING OF COMPANY EQUIPMENT
Type Description Authority Type Description Authority
MR301TEx High Performance Optical BASEEFA Relay 5000 BT
Smoke Detector [I.S.] Relay 5010 BT
MS302Ex I.R. Flame Detector [I.S.] ABS, AMSA, BASEEFA, BV S111, S112 IR Flame Detector ABS, BASEEFA [812333], BV*
CCS (ZC), DMA, DNV, MSA CCS (ZC), DMA*, MSA, KRS
GL, KRS LPCB, LRS, PRS, RRS, SAA
M500 Detector Base ABS, DMA*, DNV, MSA, KRS VdS
LRS, RNR, USCG S121 IR Flame Detector ABS, BASEEFA [812333], BV*
M500Ex Intrinsically Safe Detector Base ABS, LPCB, BV, DNV, KRS CCS (ZC), CSA, DMA*, MSA
LRS, RNR, USCG KRS, LPCB, LRS, SAA, VdS
MD501 Analogue Addressable ABS, BV, CCG, CCS (ZC) S122 IR Flame Detector ABS, BASEEFA [812333]
Heat Sensor DMA*, DNV, MSA, GL, KRS BV*, CCS (ZC), DMA*, MSA
LPCB, LRS, NKK, NMA(S) KRS, LRS, SAA
PRS, RNR, RRS, USCG S131 IR Flame Detector ABS, BASEEFA [812333], DNV
MD501Ex Intrinsically Safe Analogue ABS, BASEEFA, BV, CCS (ZC) MSAPRS, LRS, NSTC, SAA
Addressable Heat Sensor DNV, GL, KRS, LRS, NKK VdS
PRS, RNR, RRS, USCG S161 I.R. Flame Detector BASEEFA [87Y3550], DNV
MF501 Analogue Addressable Ion ABS, AMSA, BV, CCG, MSA, LPCB, LRS
Chamber Sensor CCS (ZC), DMA*, DNV, MSA S231f+ I.R. Flame Detector (Flameproof) DMA, BASEEFA [EX94C1388]
GL, KRS, LPCB, LRS, NKK LPCB (pending), DNV (pending)
NMA(S), NRPB, NSTC, PRS
RNR, RRS, USCG LRS (pending)
MF501Ex Analogue Addressable Ion ABS, BASEEFA, BV, CCS (ZC) S232f+ I.R. Flame Detector (Flameproof) DMA, BASEEFA [EX94C1388]
Chamber Sensor [I.S.] DNV, GL, KRS, LRS, NKK S231i+ I.R. Flame Detector (I.S.) DMA, BASEEFA [EX94C2080]
NRPB, PRS, RNR, RRS, USCG LPCB (pending), DNV (pending)
MR501 Analogue Addressable ABS, BV, CCG, CCS (ZC) LRS (pending)
Optical Sensor DMA*, DNV, MSA, GL, KRS S241f+ I.R. Flame Detector (Flameproof) DMA, BASEEFA [EX94C1388]
LPCB, LRS, NKK, NMA(S), PRS LPCB (pending), DNV (pending)
RNR, RRS, USCG LRS (pending)
MR501Ex Analogue Addressable ABS, BASEEFA, BV, CCS (ZC) S241i+ I.R. Flame Detector (I.S.) DMA, BASEEFA [EX94C2080]
Optical Sensor [I.S.] DNV, GL, KRS, LRS, NKK, PRS LPCB (pending), DNV (pending)
RNR, RRS, USCG LRS (pending)
MR501T Analogue Addressable High LPCB S251f+ I.R. Flame Detector (Flameproof) DMA, BASEEFA [EX94C1388]
Performance Optical Sensor LPCB (pending), DNV (pending)
MR501TEx Analogue Addressable High BASEEFA LRS (pending)
Performance Optical Sensor [I.S.] S252f+ I.R. Flame Detector (Flameproof) DMA, BASEEFA [EX94C1388]
MS502Ex Analogue Addressable ABS, AMSA, BASEEFA, BV FM
Infra Red Sensor [I.S.] CCG, CCS (ZC), DNV, NMA(S) S251i+ I.R. Flame Detector (I.S.) DMA, BASEEFA [EX94C2080]
KRS S261f+ I.R. Flame Detector (Flameproof) DMA, BASEEFA [EX94C1388]
MD601 Gr. 1 Rate of Rise Heat Detector LPCB, MIE LPCB (pending), DNV (pending)
MD611 Gr. 2 Fixed Temp. Heat Detector LPCB, MIE LRS (pending)
612H Heat detector 135 ° F Fixed/ R-of-R UL, ULC S262f+ I.R. Flame Detector (Flameproof) DMA, BASEEFA [EX94C1388]
622H Heat detector 135 ° F Fixed UL, ULC FM
632H Heat detector 200 ° F Fixed UL, ULC SB520 Sounder Booster Module ABS, BV, CCS (ZC), DMA*
MD613 Gr. 1 Rate of Rise Heat Detector VdS MSA, GL, KRS, LPCB, LRS
MD623 Gr. 2 Static Heat Detector VdS NKK, NMA(S), PRS, RNR
MF601 Ion Chamber Detector NRPB, LPCB, NSTC RRS, USCG
MF601M Ion Chamber Detector ABS, BV, DNV, GL, KRS SM520 Sounder Module ABS, BV, CCS (ZC), DMA*
MSA, LRS, NKK, PRS MSA, GL, KRS, LPCB, LRS
612I Ionisation Smoke Detector UL NKK, NMA(S), PRS, RNR
MF613 Ion Chamber Detector VdS RRS, USCG
MR601 Optical Smoke Detector LPCB, LRS, MIE T1000 Marine Controllers ABS, BV, CCS, DNV, GL, NKK
MR601M Optical Smoke Detector ABS, BVD, NV, GL, KRS KRS, LRS, RINA, RRS
MSA, NKK, PRS T110 I.R. Test Source BASEEFA [Ex84B2224]
612P Photoelectronic Smoke Detector UL, ULC, FM (pending) T210 I.R. Test Source BASEEFA [Ex84B2224]
MR613 Optical Smoke Detector VdS T280 Repeater Unit ABS, AMSA, BV, CCS (ZC)
MR601T High Performance Optical Smoke LPCB, MIE CCR, DMA*, MSA, GL, KRS
Detector LRS, NKK, PRS, RINA, RNR
612HP High Performance Optical Smoke NEDG, UL, ULC, FM (pending) RRS
Detector T281 Repeater Unit ABS, BV, CCS (ZC), DMA*
MR613T High Performance Optical Smoke VdS MSA, GL, KRS, LRS, PRS
Detector RINA, RNR, RRS, NKK
MD901 Analogue Addressable Heat LPCB, NSTC, MIE T290 Repeater Unit ABS, BV, CCS (ZC), CCG
Sensor [Minerva Marine] DMA*, MSA, GL, KRS, LRS
912H Heat Detector Head UL, ULC, FM (pending) NKK, NMA(S), RINA, RNR
MF901 Analogue Addressable Ion LPCB, NSTC RRS, USCG
Chamber Detector T291 Repeater Unit ABS, BV, CCS (ZC), CCG
MF901M Analogue Addressable Ion ABS, BV, DNV, GL, KRS, MSA [Minerva Marine] DMA*, DNV, MSA, GL*, KRS
Chamber Detector LRS, NKK, PRS LRS, NKK, NMA(S), RINA
912I Ionisation Detector Head UL, ULC, FM (pending) RNR, RRS, USCG
MR901 Analogue Addressable Optical LPCB, LRS, MIE T680 Power Unit ABS, BV, CCS (ZC), CCR, DNV
Smoke Sensor MSA, GL, KRS, LRS, NKK
MR901M Analogue Addressable Optical ABS, BV, DNV, GL, KRS, MSA PRS, RINA, RNR, RRS
Smoke Sensor NKK, PRS T880 32-Zone Fire Controller ABS, BV, CCS (ZC), CCR
912P Photoelectronic Detector Head UL, ULC, FM (pending) DMA*, DNV, MSA, GL, KRS
MR901T Analogue Addressable High LPCB, NSTC, MIE LRS, NKK, PRS, RINA, RNR
Performance Optical Sensor RRS
912HP High Performance Photoelectronic UL, FM (pending) T881 8-Zone Fire Controller ABS, AMSA, BV, CCS (ZC)
Smoke Detector Head CCR, DNV, MSA, GL, KRS
MINERVA 8 PSB LRS, NKK, PRS, RINA, RNR
MINERVA 16 LPCB, NSTC RRS
MINERVA 16R LPCB, NSTC T882 4-Zone Fire Controller ABS, BV, CCS (ZC), CCR, DNV
MINERVA 16E LPCB, NSTC, PSB MSA, GL, KRS, LRS, NKK, PRS
MINERVA 80 LPCB, NSTC, PSB RINA, RNR, RRS
MINERVA 80R LPCB, NSTC T890 80-Zone Fire Controller ABS, AMSA, BV, CCS (ZC)
MTL Intrinsically Safe Systems CSA, BASEEFA [Minerva Marine] CCG, DNV, MSA, GL*, KRS
Equipment LRS, NKK, NMA(S), PRS, RINA
NT100 8 and 16 Zone Controllers ABS, BV, DNV, FAB, GL, LPCB RNR, RRS, USCG
ANPI/BOSEC (pending), LRS T891 16-Zone Fire Controller ABS, BV, CCS (ZC), CCG
AB (Sweden) [Minerva Marine] 2.96 2.2000 DMA*, DNV, MSA, GL*, KRS
NTR08/NTR16 Releasing Panels ANPI/BOSEC (pending) NKK, NMA(S), PRS, RNR, RINA
RM520 ABS, AMSA, BV, CCS (ZC) RRS, USCG
DMA*, DNV, MSA, GL, KRS ThornNet LPCB
LPCB, LRS, NKK, NMA(S) TLK530 LPCB
PRS, RRS, USCG
Page 90
tyco Fire & Tyco Electronic
Security Product Group
Standard AutoCAD Symbols
Tyco Electronic Product Group now has an IntraNet Products and also Diagrams for many Tyco Electronic If you require any further information on this or other
site devoted to users of AutoCAD Design Packages Product Group products supplied from the UK, this will aspects of CAD development please contact Lisa
for electronic and electrical systems. be expanded to include all Tyco Electronic Product Thomson on Tel: +44 (0) 1932 743321, Fax: +44 (0)
The site has been set up with a view to utilising a Group products. 1932 743330 or e-mail: lthomson@tycoint.com or
common approach to AutoCAD output for drawing Please encourage your CAD operators to visit this alternatively visit our website at www.tycofire.com
offices using Tyco Electronic Product Group products website. Even if you're business does not use all
and systems. these products many of the symbols, schematics and
Initially this site includes Standard Symbols for Tyco drawings may be adapted quickly and easily for other
MX Technology & MX-Graph, Fire, CCTV and Access products.

Symbol Name Symbol Name Symbol Name Symbol Name


FACPMTGX.dwg FAM.dwg FAN.dwg FASU.dwg
ADDRESSABLE ACPM CONVENTIONAL CONVENTIONAL CONVENTIONAL
MODULE ASPIRATING MODULE ANALYSER ASPIRATING SAMPLING
UNIT

Symbol Name Symbol Name Symbol Name Symbol Name


FBANTGX.dwg FBAR.dwg FBATT.dwg FBELLTGX.dwg
ADDRESSABLE CONVENTIONAL FIRE CONVENTIONAL ADDRESSABLE BELL
BANSHEE SOUNDER BARRIER BATTERY UNIT
(Variants available)

Symbol Name Symbol Name Symbol Name Symbol Name


FBI.dwg FBRX.dwg FBTX.dwg FCHARGER.dwg
CONVENTIONAL BELL CONVENTIONAL BEAM CONVENTIONAL BEAM CONVENTIONAL
INTERFACE RECEIVER TRANSMITTER CHARGER

Symbol Name Symbol Name Symbol Name Symbol Name


FCMTGX.dwg FCPSTGX.dwg FCPTGX.dwg FCPWPTGX.dwg
ADDRESSABLE ADDRESSABLE ADDRESSABLE ADDRESSABLE
CONTACT MODULE CALLPOINT CALLPOINT WEATHERPROOF
CALLPOINT

Symbol Name Symbol Name Symbol Name Symbol Name


FDMTGX.dwg FDRUTGX.dwg FELIGHT.dwg FEOL.dwg
ADDRESSABLE ADDRESSABLE DOOR CONVENTIONAL CONVENTIONAL END
DETECTOR MODULE RELEASE UNIT EMERGENCY LIGHT OF LINE UNIT

Symbol Name Symbol Name Symbol Name Symbol Name


FEXIT.dwg FFDTGX.dwg FFLTGX.dwg FFTTGX.dwg
CONVENTIONAL ADDRESSABLE FLAME ADDRESSABLE XENON ADDRESSABLE FIXED
EMERGENCY LIGHT DETECTOR BEACON TEMPERATURE HEAT
DETECTOR

Symbol Name Symbol Name Symbol Name Symbol Name


FHD.dwg FHPTGX.dwg FICDP.dwg FICDPTGX.dwg
CONVENTIONAL ADDRESSABLE HIGH CONVENTIONAL ADDRESSABLE
HEAVY DUTY RELAY PERFORMANCE IONISATION DUCT IONISATION DUCT
OPTICAL SMOKE PROBE PROBE
DETECTOR
Symbol Name Symbol Name Symbol Name Symbol Name
FICTGX.dwg FICV.dwg FII.dwg FIRFDTGX.dwg
ADDRESSABLE ION CONVENTIONAL CONVENTIONAL ADDRESSABLE IR
CHAMBER SMOKE IONISTATION INTRUDER INTERFACE FLAME DETECTOR
DETECTOR DETECTOR
FLOOR/CEILING VOID
Symbol Name Symbol Name Symbol Name Symbol Name
FISH.dwg FJB.dwg FLBTGX.dwg FMEDCPTGX.dwg
CONVENTIONAL CONVENTIONAL ADDRESSABLE LAMP ADDRESSABLE MEDC
INTRINSICALLY SAFE JUNCTION BOX BUZZER CALLPOINT
HOUSING

Symbol Name Symbol Name Symbol Name Symbol Name


FMPIM.dwg FNAU.dwg FOMNI660.dwg FOMNI860.dwg
CONVENTIONAL MPIM CONVENTIONAL ADDRESSABLE ADDRESSABLE
MODULE NETWORK OMNIGUARD 660 OMNIGUARD 860
ATTACHMENT UNIT DETECTOR DETECTOR

Symbol Name Symbol Name Symbol Name Symbol Name


FOVALVE.dwg FPAC1.dwg FPAC2.dwg FPAC3.dwg
CONVENTIONAL OIL CONVENTIONAL CONVENTIONAL CONVENTIONAL
VALVE CABINET MOUNTED CABINET MOUNTED BI CABINET MOUNTED
SPEAKER DIRECTIONAL TRI DIRECTIONAL
SPEAKER SPEAKER

Page 91
tyco Fire & Tyco Electronic
Security Product Group
Symbol Name Symbol Name Symbol Name Symbol Name
FPAC4.dwg FPAC5.dwg FPANEL.dwg FPM.dwg
CONVENTIONAL CONVENTIONAL HORN CONVENTIONAL PANEL CONVENTIONAL PLANT
CEILING MOUNTED MODULE
SPEAKER

Symbol Name Symbol Name Symbol Name Symbol Name


FPODPTGX.dwg FPOTGX.dwg FPOV.dwg FPROG.dwg
ADDRESSABLE PHOTO ADDRESSABLE CONVENTIONAL CONVENTIONAL
OPTICAL DUCT PROBE OPTICAL SMOKE PHOTO OPTICAL PROGRAMMER
DETECTOR
DETECTOR
FLOOR/CEILING VOID
Symbol Name Symbol Name Symbol Name Symbol Name
FPSU.dwg FPUTGX.dwg FREP.dwg FRI.dwg
CONVENTIONAL ADDRESSABLE PLANT CONVENTIONAL CONVENTIONAL
POWER SUPPLY UNIT INTERFACE MODULE REPEATER PANEL REMOTE INDICATOR

Symbol Name Symbol Name Symbol Name Symbol Name


FRMTGX.dwg FRORTGX.dwg FRSU.dwg FRU.dwg
ADDRESSABLE RELAY ADDRESSABLE RATE CONVENTIONAL CONVENTIONAL
MODULE OF RISE HEAT REFERENCE RESET UNIT
DETECTOR SAMPLING UNIT

Symbol Name Symbol Name Symbol Name Symbol Name


FS100.dwg FS200.dwg FSB.dwg FSCI.dwg
ADDRESSABLE S100 ADDRESSABLE S200 CONVENTIONAL CONVENTIONAL
FLAME DETECTOR FLAME DETECTOR SOUNDER BOOSTER SHORT CIRCUIT
MODULE ISOLATOR

Symbol Name Symbol Name Symbol Name Symbol Name


FSDRTGX.dwg FSDRWTGX.dwg FSDTGX.dwg FSI.dwg
ADDRESSABLE ADDRESSABLE ADDRESSABLE SMOKE CONVENTIONAL
SOUNDER WEATHERPROOF DAMPER INTERFACE SHUNT INTERFACE
SOUNDER MODULE

Symbol Name Symbol Name Symbol Name Symbol Name


FSMTGX.dwg FSOUNDER.dwg FSPLY.dwg FSR.dwg
ADDRESSABLE CONVENTIONAL CONVENTIONAL CONVENTIONAL SLAVE
SOUNDER MODULE SOUNDER POWER SUPPLY UNIT RELAY

Symbol Name Symbol Name Symbol Name Symbol Name


FSUTGX.dwg FT525.dwg FT526.dwg FT527.dwg
ADDRESSABLE SHOP CONVENTIONAL CONVENTIONAL DELAY CONVENTIONAL
INTERFACE UNIT INDICATOR & MODE BUTTON ELECTRICAL MANUAL
SELECT UNIT RELEASE UNIT

Symbol Name Symbol Name Symbol Name Symbol Name


FT528.dwg FT529.dwg FTCH.dwg FTM.dwg
CONVENTIONAL CONVENTIONAL CONVENTIONAL CONVENTIONAL TIMER
MECHANICAL MANUAL ABORT BUTTON TERMINAL CHAMBER MODULE
RELEASE UNIT

Symbol Name Symbol Name Symbol Name Symbol Name


FVESLC.dwg FVESLP.dwg FVESLS.dwg FVESRT.dwg
ADDRESSABLE VESDA ADDRESSABLE VESDA ADDRESSABLE VESDA ADDRESSABLE VESDA
LASER COMPACT DETECTOR SCANNER OPTIONAL REMOTE
DISPLAY

Symbol Name Symbol Name Symbol Name


FVESSR.dwg FVMTGX.dwg FXIOM.dwg
ADDRESSABLE VESDA ADDRESSABLE VOICE CONVENTIONAL XIOM
SUB RACK MODULE MODULE

Page 92
INDEX

Page 93
INDEX

Page 94

You might also like